• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 16
  • 16
  • 13
  • 13
  • 11
  • 11
  • 11
  • 11
  • 9
  • 9
  • 9
  • 9
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Positron emission tomography of extra-striatal dopamine release

Gravel, Paul. January 2008 (has links)
Altered dopamine (DA) neurotransmission is implicated in neurological and psychiatric disorders. Positron Emission Tomography (PET) imaging of DA release has mainly been restricted to striatal areas, rich in D2/D 3 receptors, owing to the moderate affinity of the radioligands used. To measure extra-striatal DA release, where D2/D3 receptor concentrations are much smaller, an approach using a high affinity radioligand, such as [18F]Fallypride, is required. The aim of the present study was to investigate in healthy volunteers the suitability of [ 18F]Fallypride to measure variations in D2/D3 receptor occupancy, as a function of amphetamine-induced DA release, in extra-striatal regions. Six healthy male volunteers underwent two 18F-Fallypride PET sessions, following the double-blind oral administration of 0.3 mg/kg of d-amphetamine (Dexedrine) or placebo (lactose), counter-balanced for order. Following amphetamine administration, D2/D3 receptor occupancy of 18F-Fallypride was significantly reduced in striatum, but also in extra-striatal regions, including substantia nigra, amygdala, thalamus, hippocampus, and cortical areas.
2

Positron emission tomography of extra-striatal dopamine release

Gravel, Paul January 2008 (has links)
No description available.
3

Correlação entre o eletrorretinograma de padrão reverso, a tomografia de coerência óptica e a perimetria automatizada na detecção da perda neural na atrofia em banda do nervo óptico / Relationship between pattern electroretinogram, optical coherence tomography and automated perimetry for detection of neural loss in eyes with band atrophy of the optic nerve

Cunha, Leonardo Provetti 09 August 2010 (has links)
OBJETIVO: Avaliar a capacidade dos parâmetros do eletrorretinograma de padrão reverso de campo total e hemianópico em diferenciar olhos com atrofia em banda do nervo óptico e, a correlação entre as amplitudes do eletrorretinograma de padrão reverso, a espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica e a perda de campo visual nestes pacientes. MÉTODOS: Quarenta e um olhos de 41 pacientes com perda de campo visual temporal permanente por compressão do quiasma óptico e 41 controles normais foram submetidos ao eletrorretinograma de padrão reverso de estimulação de campo total e hemianópicos (temporal e nasal), a tomografia de coerência óptica, para avaliação das medidas da espessura da camada de fibras nervosas da retina e macular e, ao exame de campo visual, pela perimetria automatizada padrão. O desvio do normal da sensibilidade dos 18º centrais do campo visual foram expressos em decibéis e unidades 1/Lambert. As comparações foram feitas pelo teste t de Student. A correlação entre os parâmetros do campo visual central, do eletrorretinograma de padrão reverso e da tomografia de coerência óptica foi avaliada pela correlação de Pearson e análise de regressão linear. RESULTADOS: Os valores das amplitudes P50, N95, and P50+N95 do eletrorretinograma de padrão reverso de campo total, e de estimulação hemianópica e os valores das medidas da espessura macular e da camada de fibras nervosas da retina obtidas pela tomografia de coerência óptica foram significativamente menores nos olhos com atrofia em banda do que nos controles (P<0,001). Uma correlação significativa foi encontrada entre a perda de sensibilidade no campo visual central e as amplitudes do eletrorretinograma de padrão reverso de estimulação de campo total e nasal, mas não para o temporal. Uma correlação significativa positiva foi observada entre os parâmetros de perda de sensibilidade no campo visual e a maioria dos parâmetros da espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica. Nenhuma correlação significativa foi observada entre os parâmetros do eletrorretinograma de padrão reverso e a tomografia de coerência óptica, exceto para amplitude P50+N95 do eletrorretinograma de padrão reverso de estimulação de hemicampo nasal. Uma correlação significativa foi observada entre os parâmetros de espessura macular e da camada de fibras nervosas pela tomografia de coerência óptica, exceto entre a espessura da camada de fibras nervosas no segmento de 30º, correspondente as 9 horas do relógio e os parâmetros maculares. CONCLUSÕES: Os valores das amplitudes do eletrorretinograma de padrão reverso foram eficazes em diferenciar olhos com atrofia em banda do nervo óptico de controles normais. Em pacientes com atrofia em banda do nervo óptico, as amplitudes do eletrorretinograma de padrão reverso e medidas da espessura da camada de fibras nervosas da retina e macular correlacionaram de forma significativa com a perda de campo visual, mas não houve correlação entre eles. O eletrorretinograma de padrão reverso e a tomografia de coerência óptica detectaram a perda neural e ambos são métodos diagnósticos úteis na compreensão da correlação estrutura-função em pacientes com compressão do quiasma óptico / PURPOSE: To evaluate the ability of full-field and hemifield pattern electroretinogram parameters to differentiate between healthy eyes and eyes with band atrophy of the optic nerve and also to evaluate the relationship between pattern electroretinogram amplitude, macular and retinal nerve fiber layer thickness by optical coherence tomography, and visual field loss on standard automated perimetry in eyes with BA of optic nerve. METHODS: Forty-one eyes from 41 patients with permanent temporal visual field defects from chiasmal compression and 41 healthy subjects underwent transient fullfield and hemifield (temporal or nasal) stimulation pattern electroretinogram, standard automated perimetry and time domain- optical coherence tomography macular and retinal nerve fiber layer thickness measurements. Comparisons were made using Students t-test. Deviation from normal visual field sensitivity for the central 18° was expressed in dB and 1/Lambert units. Correlations between measurements were verified by Pearsons correlations and linear regression analysis. RESULTS: Full-field P50, N95, and P50+N95 amplitude values were significantly smaller in eyes with band atrophy than in control eyes (P<0.001). Nasal and temporal hemifield pattern electroretinogram studies revealed significant differences in N95 and P50+N95 amplitudes measurements. Pattern electroretinogram and optical coherence tomography measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between visual field sensitivity loss and full-field or nasal, but not temporal, hemifield pattern electroretinogram amplitude. Likewise a significant correlation was found between visual field sensitivity loss and most optical coherence tomography parameters. No significant correlation was observed between optical coherence tomography and pattern electroretinogram parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and retinal nerve fiber layer thickness parameters. CONCLUSIONS: Transient pattern electroretinogram amplitude measurements were efficient at differentiating eyes with band atrophy and permanent visual field defects from normal controls. In patients with chiasmal compression, pattern electroretinogram amplitude and optical coherence tomography thickness measurements were significant related to visual field loss, but not to each other. Pattern electroretinogram and optical coherence tomography quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression
4

Correlação entre o eletrorretinograma de padrão reverso, a tomografia de coerência óptica e a perimetria automatizada na detecção da perda neural na atrofia em banda do nervo óptico / Relationship between pattern electroretinogram, optical coherence tomography and automated perimetry for detection of neural loss in eyes with band atrophy of the optic nerve

Leonardo Provetti Cunha 09 August 2010 (has links)
OBJETIVO: Avaliar a capacidade dos parâmetros do eletrorretinograma de padrão reverso de campo total e hemianópico em diferenciar olhos com atrofia em banda do nervo óptico e, a correlação entre as amplitudes do eletrorretinograma de padrão reverso, a espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica e a perda de campo visual nestes pacientes. MÉTODOS: Quarenta e um olhos de 41 pacientes com perda de campo visual temporal permanente por compressão do quiasma óptico e 41 controles normais foram submetidos ao eletrorretinograma de padrão reverso de estimulação de campo total e hemianópicos (temporal e nasal), a tomografia de coerência óptica, para avaliação das medidas da espessura da camada de fibras nervosas da retina e macular e, ao exame de campo visual, pela perimetria automatizada padrão. O desvio do normal da sensibilidade dos 18º centrais do campo visual foram expressos em decibéis e unidades 1/Lambert. As comparações foram feitas pelo teste t de Student. A correlação entre os parâmetros do campo visual central, do eletrorretinograma de padrão reverso e da tomografia de coerência óptica foi avaliada pela correlação de Pearson e análise de regressão linear. RESULTADOS: Os valores das amplitudes P50, N95, and P50+N95 do eletrorretinograma de padrão reverso de campo total, e de estimulação hemianópica e os valores das medidas da espessura macular e da camada de fibras nervosas da retina obtidas pela tomografia de coerência óptica foram significativamente menores nos olhos com atrofia em banda do que nos controles (P<0,001). Uma correlação significativa foi encontrada entre a perda de sensibilidade no campo visual central e as amplitudes do eletrorretinograma de padrão reverso de estimulação de campo total e nasal, mas não para o temporal. Uma correlação significativa positiva foi observada entre os parâmetros de perda de sensibilidade no campo visual e a maioria dos parâmetros da espessura da camada de fibras nervosas da retina e macular obtidas pela tomografia de coerência óptica. Nenhuma correlação significativa foi observada entre os parâmetros do eletrorretinograma de padrão reverso e a tomografia de coerência óptica, exceto para amplitude P50+N95 do eletrorretinograma de padrão reverso de estimulação de hemicampo nasal. Uma correlação significativa foi observada entre os parâmetros de espessura macular e da camada de fibras nervosas pela tomografia de coerência óptica, exceto entre a espessura da camada de fibras nervosas no segmento de 30º, correspondente as 9 horas do relógio e os parâmetros maculares. CONCLUSÕES: Os valores das amplitudes do eletrorretinograma de padrão reverso foram eficazes em diferenciar olhos com atrofia em banda do nervo óptico de controles normais. Em pacientes com atrofia em banda do nervo óptico, as amplitudes do eletrorretinograma de padrão reverso e medidas da espessura da camada de fibras nervosas da retina e macular correlacionaram de forma significativa com a perda de campo visual, mas não houve correlação entre eles. O eletrorretinograma de padrão reverso e a tomografia de coerência óptica detectaram a perda neural e ambos são métodos diagnósticos úteis na compreensão da correlação estrutura-função em pacientes com compressão do quiasma óptico / PURPOSE: To evaluate the ability of full-field and hemifield pattern electroretinogram parameters to differentiate between healthy eyes and eyes with band atrophy of the optic nerve and also to evaluate the relationship between pattern electroretinogram amplitude, macular and retinal nerve fiber layer thickness by optical coherence tomography, and visual field loss on standard automated perimetry in eyes with BA of optic nerve. METHODS: Forty-one eyes from 41 patients with permanent temporal visual field defects from chiasmal compression and 41 healthy subjects underwent transient fullfield and hemifield (temporal or nasal) stimulation pattern electroretinogram, standard automated perimetry and time domain- optical coherence tomography macular and retinal nerve fiber layer thickness measurements. Comparisons were made using Students t-test. Deviation from normal visual field sensitivity for the central 18° was expressed in dB and 1/Lambert units. Correlations between measurements were verified by Pearsons correlations and linear regression analysis. RESULTS: Full-field P50, N95, and P50+N95 amplitude values were significantly smaller in eyes with band atrophy than in control eyes (P<0.001). Nasal and temporal hemifield pattern electroretinogram studies revealed significant differences in N95 and P50+N95 amplitudes measurements. Pattern electroretinogram and optical coherence tomography measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between visual field sensitivity loss and full-field or nasal, but not temporal, hemifield pattern electroretinogram amplitude. Likewise a significant correlation was found between visual field sensitivity loss and most optical coherence tomography parameters. No significant correlation was observed between optical coherence tomography and pattern electroretinogram parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and retinal nerve fiber layer thickness parameters. CONCLUSIONS: Transient pattern electroretinogram amplitude measurements were efficient at differentiating eyes with band atrophy and permanent visual field defects from normal controls. In patients with chiasmal compression, pattern electroretinogram amplitude and optical coherence tomography thickness measurements were significant related to visual field loss, but not to each other. Pattern electroretinogram and optical coherence tomography quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression
5

Correlação entre as espessuras da mácula e da camada de fibras nervosas da retina, medidas pelas tomografias de coerência óptica de dominio Fourier e de domínio do tempo, e a perimetria automatizada na atrofia em banda do nervo óptico / Correlation between macular and retinal nerve fiber layer Fourier domain and time domain optical coherence tomography measurements and visual field loss in band atrophy of the optic nerve

Cunha, Luciana Virginia Ferreira Costa 18 April 2011 (has links)
OBJETIVO: Investigar a correlação entre as espessuras da mácula e da camada de fibras nervosas da retina (CFNR), medidas pelas tomografias de coerência óptica de domínio Fourier (FD - OCT) e de domínio do tempo (TD - OCT) e a perda de sensibilidade no campo visual (CV) em pacientes com atrofia em banda do nervo óptico. Comparar a habilidade diagnóstica dos dois instrumentos. MÉTODOS: 36 olhos de 36 pacientes com perda de CV permanente por compressão do quiasma óptico e 36 controles normais foram submetidos ao exame de CV pela perimetria automatizada padrão (Humphrey Field Analyzer TM; Carl Zeiss Meditec, Dublin, CA), ao FD - OCT (3 D OCT-1000TM Topcon Corp., Tokyo, Japan) e ao TD - OCT (StratusTM ;Carl Zeiss Meditec Inc, Dublin, California, USA). Foram comparados os protocolos análogos de ambos os equipamentos para avaliação da espessura macular.Foi realizado a divisão macular em quatro quadrantes e em metades, sendo calculado a média da espessura macular global, a média da espessura dos quadrantes e a média da espessura das metades maculares. A média global e setorial da medida da espessura da CFNR peripapilar também foi analisada. A perda de sensibilidade no CV foi inicialmente avaliada pelo defeito temporal médio. O CV foi ainda dividido em 6 setores de acordo com a distribuição da CFNR e em 16 pontos centrais para a realização da correlação estrutura-função entre os parâmetros medidos pelo FD - OCT e a perda de sensibilidade no CV em decibéis e 1/Lambert. Foi calculado o coeficiente de correlação de Sperman e a análise de regressão linear. As áreas sobre a curva ROC e valores fixos de sensibilidade e especificidade foram calculados para cada parâmetro estudado. RESULTADOS: As medidas da espessura macular e da CFNR pelo FD - OCT e TD - OCT foram capazes de discriminar olhos com atrofia em banda do nervo óptico dos controles normais. A espessura global e setorial dos parâmetros maculares e da CFNR mostraram diferenças significativas (p<0,001) entre os doentes e os controles e os dois aparelhos tiveram desempenho semelhante na discriminação entre pacientes e controles. Em ambos existiram correlações significativas entre a perda de sensibilidade do CV e as medidas da espessura macular e da CFNR. As medidas de espessura nos quadrantes e nas metades nasais da macula, avaliadas pelo FD - OCT tiveram os melhores desempenhos nas correlações com os defeitos de CV, sendo o parâmetro com a melhor correlação, a medida do quadrante infero-nasal da mácula e a perda de sensibilidade do CV central do quadrante temporal superior central (r = 0.78, R2 = 61%, p<0,001). CONCLUSÕES: A espessura macular e a espessura da CFNR medidas pelo FD - OCT e pelo TD - OCT se correlacionaram topograficamente com a perda de sensibilidade no CV de pacientes com hemianopsia temporal por compressäo quiasmática. A correlação entre os quadrantes maculares e a perda de sensibilidade no CV, foram melhores do que aquelas entre o CV e as medidas da CFNR, principalmente nas medidas realizadas pelo FD - OCT. Este estudo demonstrou a importância clínica das medidas maculares na correlação estrutura-função e na quantificaçäo do dano neural em pacientes com compressão quiasmática, podendo ser útil na monitorização destes pacientes / PURPOSE: To investigate the relationship between fourier-domain optical coherence tomography (FD - OCT) measured macular and retinal nerve fiber layer thickness (RNFL) and visual field sensitivity loss on standard automated perimetry in eyes with permanent temporal hemianopia from chiasmal compression and compare the ability of FD - OCT and time-domain optical coherence tomography (TD - OCT) to detect axonal loss in eyes with band atrophy of the optic nerve. METHODS: One eye of each of 36 patients with permanent temporal visual field defects and 36 age- and sex-matched healthy subjects. Subjects underwent standard automated perimetry and macular and RNFL thickness measurements with FD - OCT (3 D OCT-1000® Topcon Corp., Tokyo, Japan) and TD - OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA). Macular thickness measurements as a global average, divided in four quadrants and in two halves as well as average and sectoral RNFL thickness around the optic disc were calculated. Visual field sensitivity loss was evaluated by the temporal mean defect; as deviations from normal in six sectors of the visual field and in 16 central visual field test points. Relationship between visual field sensitivity loss in decibel and 1/Lambert units and optical coherence tomography measurements were evaluated using Spearman correlation coefficients and by linear regression analysis. Receiver operating characteristic curves and sensitivities at fixed specificities were calculated for each parameter. RESULTS: Global and sectoral macular and RNFL thickness parameters showed a significant difference in eyes with band atrophy compared with controls. The strongest correlations were seen between visual field sensitivity loss and quadrantic or hemianopic nasal macular thickness measurements than with sectoral retinal nerve fiber layer thickness measurements. The highest correlation was observed between the inferonasal quadrant macular thickness and the visual field sensitivity loss in the superior temporal central visual field quadrant (r = 0.78, R2 = 61%, p <0.001). CONCLUSION: Both RNFL thickness and macular thickness FD - OCT and TD - OCT measurements were related topographically with visual field sensitivity loss in patients with temporal hemianopia from chiasmal compression and there is a stronger relationship in quadrantic macular compared to RNFL thickness measurements with FD - OCT. Macular thickness measurements could potentially be used to quantify neuronal loss in patients with chiasmal compression and could prove clinically useful for detection of damage and for monitoring these patients
6

Comparação das medidas da espessura macular e da camada de fibras nervosas retiniana para detecção de atrofia em banda do nervo óptico através da tomografia de coerência óptica / Comparison of macular thickness and retinal nerve fiber thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

Moura, Frederico Castelo 31 August 2007 (has links)
Pacientes com compressão quiasmática apresentam perda das fibras nervosas da retina nasal que decussam no quiasma óptico. Por conseguinte, ocorre perda das fibras nervosas, predominantemente, no setor nasal e temporal do disco óptico, que se manifesta por atrofia em banda do nervo óptico ao exame oftalmoscópico e hemianopsia temporal ao exame de campo visual. Trabalhos anteriores mostraram que o tomógrafo de coerência óptica é capaz de diferenciar pacientes com atrofia em banda do nervo óptico associada à hemianopsia temporal completa de indivíduos normais através da análise da camada de fibras nervosas peripapilar. Estudos em glaucoma têm sugerido que a avaliação da espessura macular poderia ser útil na quantificação da perda neural como um método alternativo ou complementar ao estudo da camada de fibras nervosas da retina. No presente estudo, a espessura macular e da camada de fibras nervosas foram avaliadas pelo tomógrafo de coerência óptica em pacientes com atrofia em banda do nervo óptico e graus variados de hemianopsia temporal. O desempenho dos parâmetros maculares para detecção da atrofia em banda do nervo óptico foi avaliado pela área sob a curva ROC (AROC) e sensibilidades para especificidades fixas e os resultados foram comparados aos parâmetros da camada de fibras nervosas peripapilar. Para identificar os parâmetros do Stratus OCT que apresentaram melhor desempenho para diferenciar pacientes com AB do nervo óptico de indivíduos normais, modelos de regressão logística foram utilizados. A correlação estrutura-função foi realizada entre o grau do defeito temporal e os valores de espessura macular e da camada de fibras peripapilar através do coeficiente de correlação de Spearman. A categorização diagnóstica dos parâmetros da camada de fibras nervosas através do banco de dados normativos foi avaliada pelos valores de sensibilidade e especificidade calculados pelo teste exato de Fisher. Quarenta e quatro olhos com atrofia em banda e 47 olhos normais foram avaliados no estudo. Entre os parâmetros maculares, os parâmetros da retina nasal apresentaram melhor desempenho para detectar atrofia em banda do nervo óptico comparados aos parâmetros da retina temporal. Não houve diferença significante (p=0,32) entre as áreas sob a curva ROC do melhor parâmetro macular (AROC=0,97) e do melhor parâmetro da camada de fibras nervosas retiniana (AROC=0,99). Na avaliação da correlação estrutura-função, os parâmetros da retina nasal apresentaram maior correlação com o defeito campimétrico comparados aos parâmetros da camada de fibras nervosas da retinal. Entre os parâmetros maculares, a espessura nasal média apresentou a maior correlação (rs=0,618). Entre os parâmetros da camada de fibras nervosas da retina, a espessura média apresentou a maior correlação (rs=0,479). Os parâmetros espessura média, espessura nasal e espessura temporal da camada de fibras nervosas da retina apresentaram melhor desempenho diagnóstico baseado na categorização diagnóstica do banco de dados normativos. Os resultados obtidos no estudo mostraram que os parâmetros maculares discriminam olhos com atrofia em banda do nervo óptico em pacientes com graus variados de defeito temporal. Além disso, os parâmetros da retina nasal podem colaborar com o exame perimétrico e os parâmetros da camada de fibras nervosas para o seguimento dos pacientes com compressão quiasmática. / Patients with chiasmal compression present damage of crossed fibers of nasal retina. Therefore, retinal nerve fiber layer loss occurs predominantly on the nasal and temporal sides of the optic disc, a pattern that can be identified on ophthalmoscopy as band atrophy of the optic nerve and on visual field as temporal hemianopia. Previous studies have been demonstrated that optical coherence tomography is able to detect retinal nerve fiber layer loss in patients with lesions of the optic chiasm and complete temporal hemianopia. Studies in glaucoma have been suggested that macular thickness measurements could be useful in quantification of optical nerve axonal loss as alternative or complement method to evaluate the retinal nerve fiber layer. The purpose of the present study was to compare macular thickness and retinal nerve fiber thickness measurements in patients with band atrophy of the optic nerve and different severities of visual field defect using optical coherence tomography. Area under the receiver operating characteristic curve (AROC) and sensitivities at fixed specificities were performed for evaluation of diagnostic accuracy of macular and retinal nerve fiber layer parameters. To identify the best optical coherence tomography measurements to differentiate band atrophy of the optic nerve patients from normal individuals, logistic regression models were performed. Association between optical coherence tomography parameters and temporal field defect were examined by Spearman coefficient of correlation. Fisher\'s exact test was performed to evaluate diagnostic ability of retinal nerve fiber parameters by optical coherence tomography in eyes with band atrophy using comparison with its internal normative database. A total of 44 eyes with band atrophy of the optic nerve and 47 normal eyes were studied. Among macular parameters, nasal retina measurements showed diagnostic accuracy better than temporal retina measurements. No statistically significant difference (p=0.32) was found between areas under ROC curve for the best macular parameter (AROC=0.97) and the best retinal nerve fiber layer parameter (AROC=0.99). Nasal retina parameters correlations were higher than retinal nerve fiber parameters. The highest correlation was observed for the mean nasal thickness (rs=0.618) for macular parameters. In retinal nerve fiber parameters, the highest correlation was observed for the average thickness (rs=0.479). In evaluation of diagnostic ability of normative database, the average thickness parameter demonstrated the highest sensitivity for detection of abnormalities in eyes with band atrophy, followed by the parameters related to the nasal and temporal quadrants. These results suggest that macular thickness measurements discriminate eyes with band atrophy of the optic nerve with different severities of temporal field defect. Results also suggest that nasal retina thickness measurements could potentially be used to evaluate retinal ganglion cell loss in patients with chiasmal compression.
7

Análise regional da dinâmica ventilatória em transplante pulmonar com tomografia de impedância elétrica / Assessment of regional ventilatory dynamics in lung transplantation, using electrical impedance tomography

Afonso Júnior, José Eduardo 23 August 2010 (has links)
INTRODUÇÃO: A monitorização da ventilação em transplante pulmonar depende de medidas estáticas e globais a partir de testes de função pulmonar e tomografia computadorizada, o que não é suficiente para detectar alterações regionais no parênquima pulmonar, que podem ser relevantes na avaliação de diferentes causas de comprometimento funcional. Tomografia de Impedância Elétrica (TIE) é uma técnica não-invasiva e livre de radiação com base na medição do potencial elétrico na superfície da parede torácica. O comportamento dinâmico e as informações quantitativas extraídas de imagens da TIE tornam possível avaliar as diferenças regionais na ventilação pulmonar. OBJETIVOS: Avaliar a ventilação regional com a TIE, em pacientes submetidos a transplante pulmonar unilateral ou bilateral e avaliar as variações ventilatórias em várias posições diferentes. MÉTODOS: A TIE foi realizada em 18 pacientes transplantados de pulmão (7 pacientes com transplante de pulmão bilateral, 6 pacientes com transplante unilateral por enfisema e 5 pacientes com transplante unilateral por fibrose), nas posições: sentada, supina, prona e decúbitos lateral direito e esquerdo. Os pacientes foram orientados a realizar 30 ciclos de ventilação espontânea e, em seguida, uma manobra de capacidade vital lenta. RESULTADOS: A comparação entre os grupos mostrou que houve diferença entre porcentagem de ventilação referente ao melhor pulmão (nos unilaterais o melhor pulmão era o transplantado e nos bilaterais o pulmão com maior ventilação na posição sentada). Na ventilação espontânea os transplantes unilaterais por enfisema e fibrose tinham 79% e 83% da ventilação gerada pelo pulmão transplantado, enquanto para os bilaterais o melhor pulmão contribuía com 57% da ventilação. Houve redução significativa na desproporção da ventilação quando comparada a ventilação espontânea com a capacidade vital (p = 0,001). Na ventilação espontânea houve variação da ventilação de acordo com a posição analisada, o que não aconteceu na capacidade vital. A medida do ângulo de fase foi próxima a zero para os bilaterais, negativa para os unilaterais por enfisema e positiva para os unilaterais por fibrose, mostrando que nos bilaterais havia sincronia entre o esvaziamento dos dois pulmões e nos grupos unilaterais havia dissincronia (diferentes constantes de tempo). CONCLUSÃO: A TIE pode ser uma ferramenta útil para o estudo pacientes transplantados de pulmão, evidenciando diferenças ocultas na dinâmica ventilatória entre os pulmões nativos e os de pulmões transplantados. Como esperado, os pacientes de transplante de pulmão unilateral exibiram uma ventilação muito mais heterogênea regionalmente. O decúbito lateral e a ventilação espontânea amplificam tais diferenças. / INTRODUCTION: Ventilation monitoring in lung transplantation is still depending on static and global measurements from lung function testing and computed tomography, what is not enough to detect regional changes in lung parenchyma, which may be relevant in evaluating different causes of functional impairment. Electrical Impedance Tomography (EIT) is a noninvasive and radiation-free technique based on the measurement of electric potentials at the chest wall surface. The dynamic behavior and the quantitative information extracted from EIT images make it possible to assess regional differences in lung ventilation. OBJECTIVES: To assess regional ventilation with EIT, in patients who underwent single or bilateral lung transplantation and to evaluate ventilatory variations in several different body positions. METHODS: We performed the EIT in 18 lung transplanted patients (7 bilateral lung transplantation patients, 6 single lung transplantation patients with emphysema and 5 single lung transplantation patients with fibrosis), in seated, supine, right, left and ventral positions. Patients were asked to perform 30 cycles of spontaneous ventilation and then a slow vital capacity maneuver. RESULTS: The comparison between groups showed that there was difference between the percentage of ventilation related to the best lung (the best lung in single lung patients was the transplanted lung and in the bilateral patients was the lung with best ventilation in the sitting position). The ventilation generated by the transplanted lung on spontaneous ventilation in single lung patients for emphysema and fibrosis were 79% and 83% respectively, whereas for the bilateral group better lung contributed with 57% of ventilation. Significant reduction in the disparity of ventilation occurred comparing the spontaneous ventilation and the vital capacity maneuver (p = 0.001). Ventilation changed in accordance with the position analyzed in spontaneous ventilation, what did not happen in vital capacity. The measurement of phase angle was close to zero for the bilateral, negative for single lung emphysema group and positive for single lung fibrosis group, showing that we had synchronicity between the emptying of both lungs in the bilateral group and disynchronicity in the single lung groups (different time constants). CONCLUSION: EIT can be a useful tool to study lung transplant patients, evidencing occult differences in lung dynamics between the native and the transplanted lung. As expected, single lung transplant patients exhibited a much more disturbed regional ventilation. The lateral decubitus and the spontaneous ventilation amplified such differences
8

Comparação das medidas da espessura macular e da camada de fibras nervosas retiniana para detecção de atrofia em banda do nervo óptico através da tomografia de coerência óptica / Comparison of macular thickness and retinal nerve fiber thickness measurements for detection of band atrophy of the optic nerve using optical coherence tomography

Frederico Castelo Moura 31 August 2007 (has links)
Pacientes com compressão quiasmática apresentam perda das fibras nervosas da retina nasal que decussam no quiasma óptico. Por conseguinte, ocorre perda das fibras nervosas, predominantemente, no setor nasal e temporal do disco óptico, que se manifesta por atrofia em banda do nervo óptico ao exame oftalmoscópico e hemianopsia temporal ao exame de campo visual. Trabalhos anteriores mostraram que o tomógrafo de coerência óptica é capaz de diferenciar pacientes com atrofia em banda do nervo óptico associada à hemianopsia temporal completa de indivíduos normais através da análise da camada de fibras nervosas peripapilar. Estudos em glaucoma têm sugerido que a avaliação da espessura macular poderia ser útil na quantificação da perda neural como um método alternativo ou complementar ao estudo da camada de fibras nervosas da retina. No presente estudo, a espessura macular e da camada de fibras nervosas foram avaliadas pelo tomógrafo de coerência óptica em pacientes com atrofia em banda do nervo óptico e graus variados de hemianopsia temporal. O desempenho dos parâmetros maculares para detecção da atrofia em banda do nervo óptico foi avaliado pela área sob a curva ROC (AROC) e sensibilidades para especificidades fixas e os resultados foram comparados aos parâmetros da camada de fibras nervosas peripapilar. Para identificar os parâmetros do Stratus OCT que apresentaram melhor desempenho para diferenciar pacientes com AB do nervo óptico de indivíduos normais, modelos de regressão logística foram utilizados. A correlação estrutura-função foi realizada entre o grau do defeito temporal e os valores de espessura macular e da camada de fibras peripapilar através do coeficiente de correlação de Spearman. A categorização diagnóstica dos parâmetros da camada de fibras nervosas através do banco de dados normativos foi avaliada pelos valores de sensibilidade e especificidade calculados pelo teste exato de Fisher. Quarenta e quatro olhos com atrofia em banda e 47 olhos normais foram avaliados no estudo. Entre os parâmetros maculares, os parâmetros da retina nasal apresentaram melhor desempenho para detectar atrofia em banda do nervo óptico comparados aos parâmetros da retina temporal. Não houve diferença significante (p=0,32) entre as áreas sob a curva ROC do melhor parâmetro macular (AROC=0,97) e do melhor parâmetro da camada de fibras nervosas retiniana (AROC=0,99). Na avaliação da correlação estrutura-função, os parâmetros da retina nasal apresentaram maior correlação com o defeito campimétrico comparados aos parâmetros da camada de fibras nervosas da retinal. Entre os parâmetros maculares, a espessura nasal média apresentou a maior correlação (rs=0,618). Entre os parâmetros da camada de fibras nervosas da retina, a espessura média apresentou a maior correlação (rs=0,479). Os parâmetros espessura média, espessura nasal e espessura temporal da camada de fibras nervosas da retina apresentaram melhor desempenho diagnóstico baseado na categorização diagnóstica do banco de dados normativos. Os resultados obtidos no estudo mostraram que os parâmetros maculares discriminam olhos com atrofia em banda do nervo óptico em pacientes com graus variados de defeito temporal. Além disso, os parâmetros da retina nasal podem colaborar com o exame perimétrico e os parâmetros da camada de fibras nervosas para o seguimento dos pacientes com compressão quiasmática. / Patients with chiasmal compression present damage of crossed fibers of nasal retina. Therefore, retinal nerve fiber layer loss occurs predominantly on the nasal and temporal sides of the optic disc, a pattern that can be identified on ophthalmoscopy as band atrophy of the optic nerve and on visual field as temporal hemianopia. Previous studies have been demonstrated that optical coherence tomography is able to detect retinal nerve fiber layer loss in patients with lesions of the optic chiasm and complete temporal hemianopia. Studies in glaucoma have been suggested that macular thickness measurements could be useful in quantification of optical nerve axonal loss as alternative or complement method to evaluate the retinal nerve fiber layer. The purpose of the present study was to compare macular thickness and retinal nerve fiber thickness measurements in patients with band atrophy of the optic nerve and different severities of visual field defect using optical coherence tomography. Area under the receiver operating characteristic curve (AROC) and sensitivities at fixed specificities were performed for evaluation of diagnostic accuracy of macular and retinal nerve fiber layer parameters. To identify the best optical coherence tomography measurements to differentiate band atrophy of the optic nerve patients from normal individuals, logistic regression models were performed. Association between optical coherence tomography parameters and temporal field defect were examined by Spearman coefficient of correlation. Fisher\'s exact test was performed to evaluate diagnostic ability of retinal nerve fiber parameters by optical coherence tomography in eyes with band atrophy using comparison with its internal normative database. A total of 44 eyes with band atrophy of the optic nerve and 47 normal eyes were studied. Among macular parameters, nasal retina measurements showed diagnostic accuracy better than temporal retina measurements. No statistically significant difference (p=0.32) was found between areas under ROC curve for the best macular parameter (AROC=0.97) and the best retinal nerve fiber layer parameter (AROC=0.99). Nasal retina parameters correlations were higher than retinal nerve fiber parameters. The highest correlation was observed for the mean nasal thickness (rs=0.618) for macular parameters. In retinal nerve fiber parameters, the highest correlation was observed for the average thickness (rs=0.479). In evaluation of diagnostic ability of normative database, the average thickness parameter demonstrated the highest sensitivity for detection of abnormalities in eyes with band atrophy, followed by the parameters related to the nasal and temporal quadrants. These results suggest that macular thickness measurements discriminate eyes with band atrophy of the optic nerve with different severities of temporal field defect. Results also suggest that nasal retina thickness measurements could potentially be used to evaluate retinal ganglion cell loss in patients with chiasmal compression.
9

Estudo comparativo do diagnóstico de edema macular secundário a oclusão de ramo da veia central da retina pela biomicroscopia de mácula, angiofluoresceinografia e tomografia de coerência óptica / Comparison of optic coherence tomography, macular biomicroscopy and fluorescein angiography for macular edema secondary to branch retinal vein occlusion

Pinheiro, Alexandre Grobberio 04 October 2007 (has links)
As Oclusões Venosas da Retina são complicações do sistema vascular retiniano com grande potencial de impacto no sentido da visão. As oclusões Venosas são classificadas de acordo com a anatomia da região acometida e podem ser divididas em oclusão de ramo e da veia central da retina. O edema macular é a principal causa de baixa acuidade visual na Oclusão de Ramo da Veia Central da Retina (OVR). Sua detecção, localização e classificação são cruciais para a prevenção e tratamento da perda visual na OVR. A Biomicrospia Macular e a Angiofluoresceinografia são os métodos tradicionais de avaliação do edema macular na OVR, a Tomografia de Coerência Óptica (TCO) é uma tecnologia nova, que permite uma avaliação objetiva da morfologia macular. O objetivo primário do presente estudo foi avaliar, em uma mesma população, a acurácia dos métodos de diagnóstico do edema macular na OVR através da análise de três quesitos, aumento da espessura macular e da sua localização, presença de cistos intra-retinianos e a presença de descolamento seroso macular (DSM). Indivíduos com OVR foram selecionados com base nos achados fundoscópicos da doença e com tempo de história da doença entre três e vinte quatro meses. Todos os sujeitos foram submetidos a exames com o Stratus OCT (TCO), Angiofluoresceinografia digital (Angio) e o exame da biomicroscopia macular com lente de Volk de 78 D (BM) dentro do período de uma semana, além de exame oftalmológico completo. As medidas utilizadas para avaliação da acurácia diagnóstica foram o índice de concordância Kappa e a sensibilidade. Dos 32 indivíduos inicialmente avaliados, 8 foram posteriormente excluídos por não cumprirem os critérios de inclusão ou de exclusão, restando 24 indivíduos para análise. Na avaliação da espessura macular, a concordância entre BM e a TCO foi substancial e significante para a detecção do aumento da espessura macular com Kappa = 0,778 (p < 0,001) e a sensibilidade foi 95,5%. Na comparação entre a BM e a TCO para a detecção de cistos intra-retinianos, a concordância foi fraca com Kappa = 0,250 (p = 0,066) e a sensibilidade foi 57,9 %. A concordância entre a Angio e a TCO para os cistos foi pobre e não significante com Kappa = 0,124 (p = 0,237) e a sensibilidade foi 58,7 %. Houve uma correlação significante entre a presença de extravasamento na angiofluoresceinografia e a presença de cistos intra-retinianos na TCO (p=0,042). Na avaliação do DSM a concordância entre a BM e a TCO foi fraca com Kappa = 0,314 (p = 0,062) e a sensibilidade foi 60%, não houve concordância entre a Angio e a TCO para a detecção do DSM com Kappa = 0 e sensibilidade de 0%, e também não houve correlação significante entre a presença de descolamento seroso na TCO e a presença de extravasamento na angiofluoresceinografia (p=0,615). Os dados obtidos no presente estudo sugeriram que o Stratus OCT têm acurácia superior para a detecção dos cistos intra-retinianos e do descolamento seroso macular, se comparado à biomicroscopia macular e à angiofluoresceinografia / Retinal Vein Occlusions are complications of the retinal vascular system that can cause a great impact on vision. The Vein Occlusions are classified according to the anatomy of the affected region and can be categorized as: branch retinal vein occlusion and central retinal vein occlusion. Macular edema is the main cause for low visual acuity in Branch Retinal Vein Occlusion (BRVO). Its detection, location and classification are crucial for the prevention and treatment of vision loss in BRVO. Both Macular Biomicroscopy and Angiofluoresceinography are traditional methods for the evaluation of the macular edema in BRVO; the Optical Coherence Tomography (OCT) is a new technology that allows for an objective evaluation of macular morphology. The main objective of the present study was to evaluate, among the same population, the accuracy of the diagnostic methods of macular edema in BRVO through the analysis of three items: the increase of macular thickness and its location, the presence of intraretinal cysts, and the presence of serous macular detachment. Patients with BRVO were selected according to the fundoscopic findings of the disease and a disease history of three to twenty-four months. All of the individuals underwent exams with the Stratus OCT, digital Angiofluoresceinography (Angio) and a macular biomicroscopy with a 78D Volk lens (MB), within a period of one week, as well as a complete ophthalmologic exam. The parameters used in the evaluation of the diagnostic accuracy were sensitivity and the kappa coefficient. Of the 32 subjects who were initially evaluated, 8 were later excluded since they did not meet inclusion or exclusion criteria. The remaining 24 subjects were analyzed. In the evaluation of macular thickness, the concordance between the MB and the OCT was substantial and significant in the detection of the increase in macular thickness, with Kappa = 0.778 (p<0.001) and a sensitivity of 95.5%. When comparing the MB and the OCT in the detection of intraretinal cysts, the concordance was fair, with Kappa = 0.250 (p = 0.066) and a sensitivity of 57.9%. The concordance between the Angio and the OCT for cysts detection was poor and non significant, with Kappa = 0.124 (p = 0.237) and a sensitivity of 58.7%. There was a significant correlation between the presence of leakage in the angiofluoresceinography and the presence of intraretinal cysts in the OCT (p = 0.042). In the evaluation of the SMD, the concordance between the MB and the OCT was fair, with Kappa = 0.314 (p = 0.062) and a sensitivity of 60% an there was no concordance between the Angio and the OCT in the detection of SMD, with Kappa = 0 and sensitivity of 0%. There was also no significant correlation between the presence of serous detachment in the OCT and the presence of leakage in the angiofluoresceinography (p = 0.615). The results obtained in the present study suggest that Stratus OCT is more accurate to the detection of intraretinal cysts and serous macular detachment than macular biomicroscopy with a 78D Volk lens, and by angiofluoresceinography
10

Estudo comparativo do diagnóstico de edema macular secundário a oclusão de ramo da veia central da retina pela biomicroscopia de mácula, angiofluoresceinografia e tomografia de coerência óptica / Comparison of optic coherence tomography, macular biomicroscopy and fluorescein angiography for macular edema secondary to branch retinal vein occlusion

Alexandre Grobberio Pinheiro 04 October 2007 (has links)
As Oclusões Venosas da Retina são complicações do sistema vascular retiniano com grande potencial de impacto no sentido da visão. As oclusões Venosas são classificadas de acordo com a anatomia da região acometida e podem ser divididas em oclusão de ramo e da veia central da retina. O edema macular é a principal causa de baixa acuidade visual na Oclusão de Ramo da Veia Central da Retina (OVR). Sua detecção, localização e classificação são cruciais para a prevenção e tratamento da perda visual na OVR. A Biomicrospia Macular e a Angiofluoresceinografia são os métodos tradicionais de avaliação do edema macular na OVR, a Tomografia de Coerência Óptica (TCO) é uma tecnologia nova, que permite uma avaliação objetiva da morfologia macular. O objetivo primário do presente estudo foi avaliar, em uma mesma população, a acurácia dos métodos de diagnóstico do edema macular na OVR através da análise de três quesitos, aumento da espessura macular e da sua localização, presença de cistos intra-retinianos e a presença de descolamento seroso macular (DSM). Indivíduos com OVR foram selecionados com base nos achados fundoscópicos da doença e com tempo de história da doença entre três e vinte quatro meses. Todos os sujeitos foram submetidos a exames com o Stratus OCT (TCO), Angiofluoresceinografia digital (Angio) e o exame da biomicroscopia macular com lente de Volk de 78 D (BM) dentro do período de uma semana, além de exame oftalmológico completo. As medidas utilizadas para avaliação da acurácia diagnóstica foram o índice de concordância Kappa e a sensibilidade. Dos 32 indivíduos inicialmente avaliados, 8 foram posteriormente excluídos por não cumprirem os critérios de inclusão ou de exclusão, restando 24 indivíduos para análise. Na avaliação da espessura macular, a concordância entre BM e a TCO foi substancial e significante para a detecção do aumento da espessura macular com Kappa = 0,778 (p < 0,001) e a sensibilidade foi 95,5%. Na comparação entre a BM e a TCO para a detecção de cistos intra-retinianos, a concordância foi fraca com Kappa = 0,250 (p = 0,066) e a sensibilidade foi 57,9 %. A concordância entre a Angio e a TCO para os cistos foi pobre e não significante com Kappa = 0,124 (p = 0,237) e a sensibilidade foi 58,7 %. Houve uma correlação significante entre a presença de extravasamento na angiofluoresceinografia e a presença de cistos intra-retinianos na TCO (p=0,042). Na avaliação do DSM a concordância entre a BM e a TCO foi fraca com Kappa = 0,314 (p = 0,062) e a sensibilidade foi 60%, não houve concordância entre a Angio e a TCO para a detecção do DSM com Kappa = 0 e sensibilidade de 0%, e também não houve correlação significante entre a presença de descolamento seroso na TCO e a presença de extravasamento na angiofluoresceinografia (p=0,615). Os dados obtidos no presente estudo sugeriram que o Stratus OCT têm acurácia superior para a detecção dos cistos intra-retinianos e do descolamento seroso macular, se comparado à biomicroscopia macular e à angiofluoresceinografia / Retinal Vein Occlusions are complications of the retinal vascular system that can cause a great impact on vision. The Vein Occlusions are classified according to the anatomy of the affected region and can be categorized as: branch retinal vein occlusion and central retinal vein occlusion. Macular edema is the main cause for low visual acuity in Branch Retinal Vein Occlusion (BRVO). Its detection, location and classification are crucial for the prevention and treatment of vision loss in BRVO. Both Macular Biomicroscopy and Angiofluoresceinography are traditional methods for the evaluation of the macular edema in BRVO; the Optical Coherence Tomography (OCT) is a new technology that allows for an objective evaluation of macular morphology. The main objective of the present study was to evaluate, among the same population, the accuracy of the diagnostic methods of macular edema in BRVO through the analysis of three items: the increase of macular thickness and its location, the presence of intraretinal cysts, and the presence of serous macular detachment. Patients with BRVO were selected according to the fundoscopic findings of the disease and a disease history of three to twenty-four months. All of the individuals underwent exams with the Stratus OCT, digital Angiofluoresceinography (Angio) and a macular biomicroscopy with a 78D Volk lens (MB), within a period of one week, as well as a complete ophthalmologic exam. The parameters used in the evaluation of the diagnostic accuracy were sensitivity and the kappa coefficient. Of the 32 subjects who were initially evaluated, 8 were later excluded since they did not meet inclusion or exclusion criteria. The remaining 24 subjects were analyzed. In the evaluation of macular thickness, the concordance between the MB and the OCT was substantial and significant in the detection of the increase in macular thickness, with Kappa = 0.778 (p<0.001) and a sensitivity of 95.5%. When comparing the MB and the OCT in the detection of intraretinal cysts, the concordance was fair, with Kappa = 0.250 (p = 0.066) and a sensitivity of 57.9%. The concordance between the Angio and the OCT for cysts detection was poor and non significant, with Kappa = 0.124 (p = 0.237) and a sensitivity of 58.7%. There was a significant correlation between the presence of leakage in the angiofluoresceinography and the presence of intraretinal cysts in the OCT (p = 0.042). In the evaluation of the SMD, the concordance between the MB and the OCT was fair, with Kappa = 0.314 (p = 0.062) and a sensitivity of 60% an there was no concordance between the Angio and the OCT in the detection of SMD, with Kappa = 0 and sensitivity of 0%. There was also no significant correlation between the presence of serous detachment in the OCT and the presence of leakage in the angiofluoresceinography (p = 0.615). The results obtained in the present study suggest that Stratus OCT is more accurate to the detection of intraretinal cysts and serous macular detachment than macular biomicroscopy with a 78D Volk lens, and by angiofluoresceinography

Page generated in 0.4644 seconds