• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 12
  • 11
  • 8
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Passagens de ions peróxido para a superfície dentária externa após clareamento com peróxido de hidrogênio /

Palo, Renato Miotto. January 2009 (has links)
Orientador: Idomeo Bonetti Filho / Banca: Cacio de Moura-Neto / Banca: Ivaldo gomes de Moraes / Banca: Marcia Carneiro Valera / Banca: Fabio Luiz Camargo Villela Berbert / Resumo: O objetivo deste trabalho foi avaliar a quantidade de peróxido que passa da câmara pulpar para a superfície dentária externa durante o clareamento interno no esmalte, cemento e dentina. Foram utilizados 50 incisivos bovinos extraídos que receberam aberturas coronárias, as raízes foram cortadas a 5 mm da junção amelo-cementária e foi realizado um tampão de 2mm de ionômero de vidro selando a entrada do canal. A extremidade apical dos espécimes foi isolada externamente com resina composta fotoativada. Os dentes foram então impermeabilizados completamente, deixando exposto somente as áreas a serem estudadas. As câmaras coronárias foram preenchidas com peróxido de hidrogênio a 35%. Os dentes foram divididos em três grupos experimentais e dois grupos controles, com 10 espécimes cada. GE - esmalte exposto a ser avaliado; GC - cemento exposto a ser avaliado; GD - dentina exposta a ser avaliada; e dois grupos Controle: GC1 - sem a presença de clareador internamente e sem impermeabilização e GC2 - câmara pulpar preenchida com clareador e impermeabilização total. Cada amostra foi colocado no interior de reservatórios individuais com 1000μl de solução tampão de acetato 2M (pH 4,5). Após 7 dias a 37±1ºC a solução foi transferida para um tubo de ensaio onde foram adicionados 100μl do corante violeta leucocristal e 50 μl de peroxidase, resultando em uma solução de coloração azul. A mensuração da absorbância foi feita em um espectrofotômetro e convertida em μg/ml de peróxido. Para avaliar se houve diferença entre os grupos experimentais e controle, realizou-se os testes de Kruskall-Walis e Dunn-Bunferroni e os resultados mostraram os íon passaram mais pela dentina exposta, seguida da dentina recoberta pelo esmalte e dentina recoberta pelo cemento, sem diferenças estatísticas. Todos os grupos experimentais foram diferentes dos controles... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was evaluated the pulp chamber penetration of peroxide bleaching agent to the root surface during the internal bleach technique in the enamel, dentin and cement. Bovine teeth were sectioned 5mm apical of the cemento-enamel junction and was performed a 2mm cervical seal with glass ionomer cement. The external apical part of samples was filled with composite resin. The teeth were divided into three experimental groups and two control groups: GE - exposition of enamel; GC - exposition of cement; GD - exposition of dentin and control groups: GC1 - no presence of internal agent bleaching e no waterproof and GC2 - pulp chamber filled with bleaching agent and total waterproof. Each sample was placed inside of individual flasks with 1000μl of acetate buffer solution 2M (pH 4.5). After 7 days, the buffer solution was transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined by spectrophotometer and converted into microgram equivalents of hydrogen peroxide. Data were submitted to Kruskal-Wallis, and Dunn-Bunferroni tests. The results showed that the ions penetration was higher in dentin followed by enamel and cement. All experimental groups presented statistical differences to the control groups. / Doutor
2

Efeito citotóxico trans-amelodentinário de um gel clareador com 35% de peróxido de hidrogênio aplicado sobre dentes restaurados ou não com resina composta /

Sacono, Nancy Tomoko. January 2011 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: André Luiz Fraga Briso / Banca: Marcelo Giannini / Banca: Edson Alves de Campos / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo do estudo foi avaliar a citotoxicidade trans-amelodentinária de um gel clareador com 35% de H2O2 aplicado sobre dentes com ou sem restauração de resina composta e submetidos ou não a procedimento de envelhecimento. Cavidades preparadas em discos de esmalte/dentina obtidos de dentes bovinos íntegros foram restauradas com sistema adesivo autocondicionante e resina composta. Os discos foram armazenados em solução aquosa por 24 horas ou 6 meses e o procedimento de termociclagem foi realizado somente nos grupos armazenados por 6 meses. Os discos foram posicionados em câmaras pulpares artificiais e distribuídos em grupos: Íntegros 24 horas; Íntegros 24 horas clareados; Íntegros 6 meses; Íntegros 6 meses clareados; Restaurados 24 horas; Restaurados 24 horas clareados; Restaurados 6 meses; e Restaurados 6 meses clareados. O gel clareador foi aplicado sobre os discos por 15 minutos (1 aplicação) ou por 45 minutos (3 aplicações consecutivas de 15 minutos cada), sendo que os extratos (meio de cultura em contato com a dentina + componentes dos gel clareador que se difundiram através dos discos) foram recolhidos e aplicados por 1 hora sobre células odontoblastóides MDPC-23 em cultura (12.500 células/cm2). Para o experimento no qual o gel clareador foi aplicado somente uma vez, observouse redução significativa do metabolismo celular apenas para o grupo de dentes restaurados quando comparado ao controle (íntegros 24 horas não clareados) e ao grupo restaurado não clareado, independente do tempo de armazenamento (Tukey, p<0,05). Quando o gel clareador foi aplicado por três vezes consecutivas, houve diminuição do metabolismo celular estatisticamente significante em todos os grupos clareados (Mann-Whitney, p<0,05), sendo observadas intensas alterações morfológicas das células MDPC-23. Entretanto, não houve diferença com relação a presença de restauração e o tempo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this in vitro study was to evaluate the trans-enamel and transdentinal cytotoxic effects of a 35% hydrogen peroxide (H2O2) bleaching gel applied on non-restored or restored teeth, submitted or not to aging by water storage and thermocycling. Enamel/dentin discs were obtained from bovine central incisors and restored or not with self-etching adhesive system and composite resin. These discs were storage in water for 24 hours or 6 months (aging). Thus, the discs were adapted individually in artificial pulp chambers and distributed according to the following treatments: non-restored teeth stored for 24 hours submitted or not to bleaching procedures; non-restored teeth stored for 6 months submitted or not to bleaching procedures; restored teeth stored for 24 hours submitted or not to bleaching procedures; and restored teeth stored for 6 months submitted or not to bleaching procedures. The bleaching gel was left in contact with the enamel surface for 15 minutes (1 application) or for 45 minutes (3 applications of 15 minutes each). The extracts (culture medium in contact to the dentin surface of the discs + bleaching agents components that diffused across the discs) were collected and applied on previously cultured MDPC-23 cells (12.500 cells/cm2) for 1 hour. Cell metabolism was evaluated by the MTT assay and cell morphology by scanning electron microscopy. One application of bleaching gel in the enamel surface of the discs caused a significant decrease in cell metabolism only in the restored discs in comparison with control discs (unbleached and non-restored discs stored for 24 hours) and unbleached restored discs, regardlles of the storage time (Tukey, p<0.05). On the other hand, bleaching agent applied for three consecutive times on enamel caused a significant decreased in cell metabolism in all bleached discs (Mann- Whitney, p<0.05). However, there were no differences between... (Complete abstract click electronic access below) / Doutor
3

Sensibilidade dolorosa e efetividade do clareamento dental de consultório /

Bortolatto, Janaína Freitas. January 2011 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: Marcelo Ferrarezi de Andrade / Banca: Renato Herman Sundfeld / Resumo: Vários aspectos da técnica de clareamento dental de consultório permanecem controversos. Neste trabalho foram estudadas a sensibilidade dolorosa e a efetividade determinadas por diferentes tratamentos clareadores. Participaram deste estudo 60 voluntários de ambos os gêneros, com idades variando de 18 a 25 anos que foram aleatoriamente distribuídos em 3 grupos. GI: peróxido de hidrogênio a 35% sem ativação por luz, GII: o mesmo peróxido ativado por dispositivo de luz conjugada LED/LASER e GIII: gel clareador a 15% contendo nanopartículas de óxido de titânio nitrogenado ativado por luz conjugada LED/LASER. A sensibilidade dos pacientes durante as sessões de clareamento foi avaliada utilizando uma escala VAS modificada. A alteração de cor determinada pelos protocolos de clareamento foi mensurada por espectroscopia de reflectância (Vita Easy Shade®,Vident, Brea, CA, USA). Os valores de ΔL (luminosidade), ΔE (variação de cor) e sensibilidade provocada pelos tratamentos (S) foram analisados por meio do método de equações de estimação generalizadas (GEE), comparações múltiplas ad Hoc de Bonferroni com significância de 5%. No estudo 1, realizado para avaliar a eficiência da utilização da luz conjugada LED/Laser, os voluntários de GI relataram maior freqüência e intensidade de sensibilidade provocada pelo tratamento clareador (37,6 ± 5,9% para GI contra 11,1 ± 3,3% de GII). O clareamento em GII foi mais eficiente que em GI (p>0,05). No estudo 2, a utilização do gel clareador H2O2 a 15% contendo TiO_N resultou em menor freqüência e intensidade de sensibilidade provocada que em GI (37,6 ± 6,1% para GI contra 11,9 ± 5,0% de GII) e maior eficiência de clareamento (p>0,05). Concluiu-se que o método de fototermo catalisação com luz conjugada LED/Laser utilizada em conjunto com agente clareadores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Several aspects of in-office dental bleaching remain controversial. In this study, we studied the painful sensitivity and effectiveness determined using different bleaching techniques. The study included 60 volunteers of both genres, with ages ranging from 18 to 25 years who were randomly divided into 3 groups. GI: hydrogen peroxide 35% without activation by light, GII: the same peroxide-activated device LED / Laser and GIII: 15% whitening gel containing nanoparticles of titanium oxide nitrogen activated by coupled light LED / Laser. The sensitivity of the patients during the bleaching treatments was evaluated using a modified VAS scale. The color change determined by the protocols of bleaching was measured by reflectance spectroscopy (Vita Easy Shade ®, Seer, Brea, CA, USA). The values of ΔL (brightness), ΔE (color variation) and sensitivity caused by the treatments (S) were analyzed by the method of generalized estimating equations (GEE), multiple comparisons with Bonferroni ad hoc 5% significance. In study 1, conducted to evaluate the efficacy of use of coupled light LED/Laser, GI volunteers reported a higher frequency and intensity of sensitivity caused by bleaching treatment (37.6 ± 5.9% for GI against 11.1 ± 3.3% of GII). The Bleaching was more efficient in GII than GI (p> 0.05). In study 2, the use of gel co 15% H2O2 containing TiO_N resulted in a lower frequency and intensity of sensitivity caused in GI (37.6 ± 6.1% for GI vs. 11.9 ± 5.0% of GII) and greater efficiency of bleaching (p> 0.05). It was concluded that the method of catalyzing photothermo reaction with coupled light LED/Laser used in conjunction with bleaching agent type homogenous advanced oxidation process (POAHo) allows both the reduction of sensitivity caused as time of treatment and the agent of lower concentration reduces sensitivity, increasing safety of tooth whitening, with the same efficiency as the traditional agent / Mestre
4

Citotoxicidade trans-amelodentinária e alterações estruturais no esmalte após clareamento com géis caseiros a base de peróxido da carbamida /

Soares, Diana Gabriela de Sousa. January 2010 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Eunice Teresinha Giampaolo / Banca: Marcelo Gianini / Resumo: No clareamento dental caseiro são utilizados géis clareadores contendo baixas concentrações de peróxido de carbamida (PC). Entretanto, o componente ativo responsável pelo clareamento é o peróxido de hidrogênio (H2O2), o qual pode se difundir através do esmalte e dentina e causar efeitos tóxicos sobre células pulpares. Portanto, o objetivo deste trabalho foi avaliar a citotoxicidade trans-amelodentinária de géis clareadores à base de PC sobre células odontoblastóides MDPC- 23 após diferentes tempos de contato dos produtos com o esmalte, bem como o efeito do clareamento na estrutura dental. Para avaliação da citotoxicidade, discos de esmalte/dentina obtidos de incisivos bovinos foram adaptados em câmaras pulpares artificiais. Géis clareadores com 10% ou 16% de PC foram aplicados por 8 horas diárias sobre a superfície de esmalte pelos períodos de 1, 7 ou 14 dias. Os extratos (meio de cultura + produtos do gel clareador que se difundiram através do esmalte/dentina) foram aplicados por 1 hora sobre as células em cultura, sendo realizada avaliação do metabolismo celular pelo teste do MTT (α=5%; Anova um critério e teste de Tukey), e da morfologia celular por MEV. Para avaliação das alterações estruturais do esmalte, foi realizada mensuração da microdureza Knoop (α=5%; Anova dois critérios e teste de Tukey) em blocos de esmalte (50g/15s) antes do clareamento e nos períodos de 1, 7 e 14 dias, bem como avaliação da morfologia superficial por MEV. Os resultados não demonstraram diferença significante para o metabolismo celular entre o grupo controle e nos grupos onde foi aplicado o gel com PC a 10% (p>0.05). Já para os grupos clareados com 16% de PC, foi observado diferença significante nos períodos de 1, 7 e 14 dias quando comparados ao grupo controle (p<0.05). Não houve diferença significante quando se comparou os grupos 10% e 16% de PC em todos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The home bleaching technique uses gels with low concentrations of carbamide peroxide (CP). However, the hydrogen peroxide is the active component and can difuse by enamel and dentine to cause toxic effects on pulp cells. The purpose of this study was to evaluate the trans-enamel and transdentinal cytotoxicity of bleaching gels based on carbamide peroxide (CP) on odontoblast-like cells after different contact times of the products with enamel, and the effects of bleaching on the tooth structure. To analyze the citotoxicity, enamel/dentine discs were obtained from bovine incisors and placed in artificial pulp chambers. Bleaching gels containing 10% or 16% CP were applied for 8 hours/day on the enamel side of the discs during periods of 1, 7 or 14 days. The extracts (culture medium plus bleaching gel products that diffused through the discs) were collected and applied on previously cultured MDPC-23 cells for 1 hour. Cell metabolism was evaluated by the MTT assay (α=0.05; one-way ANOVA and Tukey's test), and the cell morphology was analysed by SEM. To evaluate the structural changes on the enamel, the Knoop microhardness was analized (α=0.05; two-way ANOVA and Tukey's test) on enamel blocks (50g/15s) before and after 1, 7 and 14 applications of bleaching agent, and the morphological surface was analized by SEM. There were no significant difference (p>0.05) for cell metabolism between the controls and the groups bleached with 10% CP gel. In the groups bleached with 16% CP gel, however, cell metabolism decreased significantly (p<0.05) at 1, 7 and 14 days. There was no significant difference (p>0.05) among 1, 7 or 14 applications of the gels for either of the CP concentrations. The microhardness for the groups bleached with 10% CP gel have difference with the control group after 7 and 14 applications. For the groups bleached with 16% of CP, significant difference was observed in all periods... (Complete abstract click electronic access below) / Mestre
5

Efeito da ativação química do gel de peróxido de carbamida a 10% no clareamento dental /

Batista, Graziela Ribeiro. January 2010 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Andrea Anido Anido / Banca: Alessandra Bühler Borges / Resumo: O objetivo deste estudo foi avaliar a eficiência de agentes ativadores químicos, em aumentar a efetividade do tratamento clareador pela técnica auto-administrada, utilizando gel de peróxido de carbamida a 10%. Foram utilizados 145 dentes incisivos bovinos e de cada dente foram obtidos 2 discos de esmalte-dentina das faces vestibulares, empregando-se uma broca tipo trefina, totalizando 290 espécimes, cada um com 1mm de esmalte, 1mm de dentina e 3 mm de diâmetro. A leitura inicial da cor dos espécimes foi feita, utilizando-se o sistema CIE L*a*b*, por meio de um espectrofotômetro CM 2600d (Konica Minolta). Os espécimes foram divididos em grupos de forma estratificada de acordo com o valor de L* apresentado. Foi utilizado para todos os grupos um gel de peróxido de carbamida a 10%, sendo que foi determinado um grupo controle positivo (CP), onde não foi adicionado nenhum agente químico e um grupo controle negativo (CN), onde os espécimes ficaram apenas submersos em solução de saliva artificial, sem receber nenhum tipo de gel clareador. Os demais grupos foram subdivididos de acordo com o tipo de ativador químico adicionado ao gel e a concentração deste agente: GM - Gluconato de Manganês, CM - Cloreto de Manganês, GF - Gluconato Ferroso, CF - Cloreto Férrico e SF - Sulfato Ferroso. Para cada agente foram testadas 3 diferentes concentrações, resultando em 3 subgrupos. Sobre a superfície de esmalte destes espécimes, foi aplicado o gel clareador, permanecendo por um período de 8h, após as quais, estes foram lavados e imersos em saliva artificial por 16h, e posteriormente feitas novas aplicações do gel clareador, durante 14 dias subseqüentes. Foram feitas avaliações de cor após decorridos 7 dias de clareamento, e novamente após 14 dias de clareamento. Os dados obtidos foram analisados pelo teste de análise da variância paramétrica e teste Tukey... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the efficiency of chemical activating agents, to increase the effectiveness of the home bleaching technique, using 10% carbamide peroxide gel. Were used 145 bovine incisors and from each tooth were obtained 2 discs of enamel-dentin from the buccal surface, through a trephine bur, totaling 290 specimens, which had 1 mm of enamel, 1mm of dentin and 3 mm of diameter for each. The initial measurement of the color of specimens was made by a spectrophotometer CM 2600d (Konica Minolta), using the CIE L* a* b* system. The specimens were divided into groups in a stratified manner according to the value of L*. For all the tested groups was used a 10% carbamide peroxide gel, and was determined a positive control group (CP), where there was no chemical agent added, a negative control group (CN), where the specimens were submerged in a solution of artificial saliva, without receiving any kind of bleaching gel and the other groups were subdivided according to the type of chemical activator added to the gel and the concentration of agent, namely: GM - Manganese Gluconate, CM - Manganese chloride, GF - Ferrous gluconate, CF - Ferric Chloride, SF - Ferrous Sulfate. For each agent were tested 3 different concentrations, resulting in 3 subgroups. On the enamel surface of these specimens, were applied the bleaching gel and kept for a period of 8 h, after which, they were washed and immersed in artificial saliva for 16 h, and then were made new applications of bleaching gel for 14 subsequent days. Color assessments were made 7 days after the bleaching treatment begining, and again after 14 days of bleaching treatment begining. The data were analyzed by the test of repeated-measures ANOVA and Tukey's test. The obtained results showed statistically significant differences (p = 0.0000)... (Complete abstract click electronic access below) / Mestre
6

Estudo "in vitro" em MEV da morfologia do esmalte, dentina, cemento e da junção amelocementária humanos antes e após a clareação /

Esberard, Roberta Ramalho. January 2004 (has links)
Orientador: Idomeo Bonetti Filho / Banca: Maria Salete Machado Cândido / Banca: Lilian Rosane Neuvald / Resumo: O objetivo desse estudo foi avaliar, em microscopia eletrônica de varredura, a morfologia do esmalte, da dentina, do cemento e, principalmente, da junção amelocementária humanos após o processo de clareação dentária, comparando-se a ação agressiva das diferentes técnicas de clareação e dos agentes clareadores sobre os tecidos que compõem a junção amelocementária. Quarenta e cinco dentes foram selecionados e seccionados ao meio, no sentido vestíbulo-lingual, de modo que obteve-se noventa espécimes. Assim, quarenta e cinco espécimes serviram de controle e seus pares foram submetidos às seguintes técnicas de clareação: Grupo I- clareação externa com peróxido de carbamida 10% (Opalescence); Grupo II- clareação externa com peróxido de hidrogênio 35% (Lase Peroxide); Grupo III- clareação externa com peróxido de hidrogênio 35% (Opalescence Xtra); Grupo IV- clareação interna/externa com peróxido de hidrogênio 35% (Lase Peroxide); Grupo V- clareação interna/externa com peróxido de hidrogênio 35% (Opalescence Xtra) e Grupo VI- clareação interna com pasta de perborato de sódio + peróxido de hidrogênio 30 V. Após as clareações, todos os espécimes, clareados ou não, foram avaliados em MEV. Os espécimes dos Grupos I, II e III foram avaliados externamente e os espécimes dos Grupos IV, V e VI foram avaliados interna e externamente. A análise microscópica mostrou que ocorreram alterações no esmalte, no cemento e na dentina de todos os espécimes clareados, porém, a junção amelocementária foi a parte mais afetada pelos agentes clareadores estudados, os quais promoveram mudanças no padrão da junção, aumentado a exposição da superfície dentinária e formando junções do tipo "gaps" ou fenestradas, exibindo extensas áreas de cemento separado do esmalte, sem cemento intermediário e com exposição dos túbulos dentinários. Aplicou-se o... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to evaluate in SEM the effects of bleaching agents on the surface of human enamel, dentin, cementum and cementoenamal junction, comparing the action of the different techniques and bleaching agents used. Forty five teeth were selected and sectioned longitudinally so ninety specimens were obtained. Forty five specimens served as controls and the other ones were bleached by sixs protocols: Group I- external bleaching with 10% carbamide peroxide (Opalescence); Group II- external bleaching with 35% hydrogen peroxide (Lase Peroxide); Group III- external bleaching with 35% hydrogen peroxide (Opalescence Xtra); Group IV- internal/external bleaching with 35% hydrogen peroxide (Lase Peroxide); Group V- internal/external bleaching with 35% hydrogen peroxide (Opalescence Xtra) and Group VI- intracoronal bleaching with paste of sodium perborate mixed with 9% hydrogen peroxide. All the specimens were examined in SEM. The specimens of the Groups I, II and III were analised externally and the specimens of the Groups IV, V and VI were analised internal and externally. The SEM analysis showed some changes on the morphology of enamel, dentin and cementum of all bleached specimens, but the cementoenamel junction were the most affected part of the teeth. The bleaching agents used in this study caused alterations on the shapes of the cementoenamel junction increasing the exposition of dentin in this area and separating the enamel and the cementum. Kruskal-Wallis test was applied (H=6,947). The Groups I, III, V and VI showed similar results but the Groups II and IV showed identical behavior, more agressive than the others, but not statiscally significant. / Mestre
7

Efeito do tratamento com gel clareador na relação cálcio-fósforo do esmalte dentário /

Scannavino, Fábio Luiz Ferreira. January 2008 (has links)
Resumo: O clareamento dentário tem sido uma prática popular no consultório odontológico, pois remove pigmentações que tornam o dente escuro, obtendo-se dessa maneira um resultado estético satisfatório. O objetivo do estudo foi avaliar a relação Cálcio-Fósforo (Ca-P) e o efeito da saliva nos dentes submetidos ao clareamento dentário com peróxido de hidrogênio 35%. Foram utilizados 60 espécimes provenientes de 30 incisivos centrais bovinos hígidos, divididos em seis grupos distintos. Os espécimes do grupo controle foram imersos em água destilada. No grupo 1, realizou-se somente clareamento com peróxido de hidrogênio 35% ativado por LED. No grupo 2 foi realizado o clareamento com peróxido de hidrogênio 35% e imersão em saliva artificial por dois dias. No grupo 3 foi realizado o clareamento com peróxido de hidrogênio 35% e aplicação de flúor tópico neutro 2%. No grupo 4 após o clareamento com peróxido de hidrogênio 35% seguido de flúor tópico neutro 2%, os espécimes foram imersos em saliva artificial por dois dias e, no grupo 5 repetiu-se o procedimento do grupo 4 com a imersão em saliva artificial por quinze dias. Todos os espécimes foram preparados para análise por espectrometria de emissão atômica com plasma acoplado indutivamente (ICP-AES). A análise de variância revelou diferença estatística (p<0.05) entre os grupos: o grupo 3 apresentou redução de 7,5% na relação Ca-P comparado ao controle. No entanto, os valores dos grupos 1, 4 e 5 não diferiram significantemente do grupo controle. Os resultados evidenciam que o clareamento produz uma redução na proporção Ca-P que pode ser minimizada pela ação da saliva. / Abstract: Teeth whitening has been a popular procedure in dental offices, because it removes pigmentations that make a tooth become dark, obtaining in this way a satisfactory aesthetic outcome. The aim of this study was to assess the Calcium-Phosphorus (Ca-P) and the effects of saliva on the teeth that had undergone whitening using hydrogen peroxide 35%. 60 specimens from bovine incisors were used, divided into six distinct groups. The specimens from the control group were immersed in distillated water. In group 1, the whitening was made by using hydrogen peroxide 35% activated by LED. In group 2, the whitening using hydrogen peroxide 35% and immersion in artificial saliva for two days was performed. In group 3, the whitening was made by with hydrogen peroxide 35% and application of neutral topic fluoride 2%. In group 4, after the whitening using hydrogen peroxide 35% followed by neutral topic fluoride 2%, the specimens were immersed in artificial saliva for two days and, in group 5, the same procedure as in group 4 was performed, but they were immersed in artificial saliva for 15 days. All specimens were prepared for analysis for Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The variance analysis revealed statistical difference (p<0.05) between the groups, and group 3 presented a 7.5% reduction in to Ca-P compared to control. However, the values for groups 1, 4, and 5 did not differ significantly from the control group. The results show that whitening produces a reduction in the ratio Ca-P that can be minimized by the action of the saliva. / Orientador: Lourdes Aparecida Martins dos Santos-Pinto / Coorientador: Antonio Carlos Hernandes / Banca: Angela Cristina Cilense Zuanon / Banca: Lizeti Toledo de Oliveira Ramalho / Banca: Maria Cristina Borsatto / Banca: Marlei Seccani Galassi / Doutor
8

Avaliação dos efeitos causados por diferentes sistemas de clareamento dental sobre a estrutura superficial do esmalte e resina composta restauradora /

Daniel, Carolina Pratti. January 2011 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Flávia Magnani Bevilacqua / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo deste estudo foi avaliar as alterações de microdureza, rugosidade e morfologia superficial do esmalte e da resina composta após diferentes técnicas de clareamento dental. Para isto, incisivos bovinos foram selecionados, sendo confeccionadas cavidades padronizadas na face vestibular, as quais foram restauradas com resina composta. Os dentes foram distribuídos em grupos (n=6), de acordo com o tratamento proposto: G1- clareamento com gel de peróxido de carbamida (PC) 10%; G2 - clareamento com gel contendo 38% peróxido de hidrogênio (PH); G3- clareamento com gel contendo 38% de PH associado à irradiação com luz. Para G1, o agente clareador foi aplicado por 8 horas diárias durante 21 dias. Para G2 e G3, foram realizadas 3 sessões, compostas por 3 aplicações do gel clareador por 15 minutos, com intervalos de 7 dias entre as sessões, sendo que em G3 foi aplicada luz LED (470nm) por 6 minutos. Durante o intervalo das aplicações do gel clareador, todos os espécimes foram armazenados em saliva artificial. A microdureza Knoop do esmalte e da resina composta foi avaliada antes do procedimento clareador e nos períodos de 1, 7, 14 e 21 dias pós-clareamento. A rugosidade superficial foi analisada por meio de um rugosímetro e a morfologia superficial por um microscópio de força atômica. Os dados foram analisados pelos testes de Mann-Whitney e Wilcoxon. Observou-se diminuição significante na dureza do esmalte para G2 e G3 após a 2ª e 3ª sessões, respectivamente, em relação à dureza inicial (p<0,05). Para a resina composta, esta alteração foi observada em G1 apenas após 21 dias, e em G2 e G3 após a 3ª sessão (p<0,05). Alterações significantes na rugosidade e morfologia superficial foram observadas apenas para o esmalte do grupo G1 (p<0,05). Concluiu-se que o gel com 10% de PC... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate changes in microhardness, roughness and surface morphology of enamel and composite resin after different techniques of tooth bleaching. Standardized cavities prepared on the buccal surface of bovine incisors were restored with composite resin. The teeth were divided into groups (n=6) according to the following treatments: G1 - bleaching with 10% carbamide peroxide (CP) gel; G2 - bleaching with 38% hydrogen peroxide (HP) gel; G3 - bleaching with 38% PH gel associated to light irradiation. In G1, the whitening agent was applied for 8 hours daily during 21 days. In G2 and G3, three sessions characterized by three applications of bleaching gel for 15 minutes, with intervals of 7 days between sessions were performed. In G3, the bleaching gel was irradiated with LED (470nm) for 6 minutes. During the intervals among applications of the bleaching gel on enamel, all specimens were stored in artificial saliva. The Knoop microhardness of enamel and composite resin was evaluated before the bleaching procedure and at 1, 7, 14 and 21 days after this treatment. The roughness and superficial morphology (atomic force microscope) were evaluated before and at 21 days after the bleaching procedure. Data were analyzed by Mann-Whitney and Wilcoxon statistical tests. It was observed a significant decrease in hardness of enamel to G2 and G3 after the 2nd and 3rd bleaching sessions, respectively, when compared to the initial enamel hardness (p <0.05). For composites, this change was only observed in G1 after 21-day treatment, and in G2 and G3 after the third bleaching session (p <0.05). Significant changes in roughness and surface morphology of enamel was observed only in G1 (p <0.05). According to the experimental conditions, it was possible to conclude that the bleaching gel with... (Complete abstract click electronic access below) / Mestre
9

Avaliação in vitro da efetividade de associações de agentes clareadores na alteração da cor de dentes manchados por pigmentos sangüineos /

Yui, Karen Cristina Kazue. January 2006 (has links)
Orientador: José Roberto Rodrigues / Banca: Marianne Spalding / Banca: Maria Antonio Pereira / Banca: Sérgio Eduardo de Paiva Gonçalves / Banca: Maria Amélia Máximo de Araújo / Resumo: O objetivo deste estudo foi avaliar in vitro a efetividade de três associações de materiais clareadores na técnica mediata de clareamento de dentes tratados endodonticamente. Foram utilizados 48 pré-molares humanos íntegros, pigmentados artificialmente com sangue humano. Após preparo biomecânico, os canais radiculares foram obturados e o tampão cervical foi confeccionado com 3mm de cimento de fosfato de zinco ao nível da junção amelo-cementária. Os dentes foram divididos em quatro grupos (n=12): C (controle, sem material clareador), A1 (perborato de sódio + água destilada), A2 (perborato de sódio + peróxido de carbamida a 10%) e A3 (perborato de sódio + peróxido de carbamida a 35%). Os materiais clareadores foram trocados aos sete e 14 dias. Concluiu-se que o perborato de sódio associado ao peróxido de carbamida (tanto a 10%, como a 35%) foi mais efetivo do que quando associado à água destilada. / Abstract: The aim of this study was to evaluate in vitro the effectiveness of three associations of bleaching agents on artificially stained pulpless teeth. Forty-eight recently extracted intact human premolars were stained by immersing them in human blood, and divided into four groups. All teeth were endodontically treated and 3mm of zinc phosphate cement was placed at the cementoenamel junction. The teeth were divided into one control group and three test groups (n=12): C) control group, without bleaching agent, A1) sodium perborate with water, A2) sodium perborate with 10% carbamide peroxide, A3) sodium perborate with 35% carbamide peroxide. On days 7 and 14, each pulp chamber was refilled with fresh bleaching paste. Color coordinates of CIELAB color system were measured and assessed with the aid of a dental spectrophotometer (EasyShade®, Vita). It was concluded that sodium perborate mixed with carbamide peroxide (10% or 35%) was more effective than mixed with water. / Doutor
10

Clareamento com peróxido de hidrogênio a 35% ativado por diversas fontes de energia : análise térmica e microdureza do esmalte /

Kabbach, William. January 2008 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: João Carlos Gomes / Banca: Carlos Alberto de Souza Costa / Resumo: O objetivo do presente estudo foi avaliar in vitro a variação de temperatura e a microdureza Knoop superficial do esmalte durante o processo de clareamento dental com peróxido de hidrogênio a 35% sob irradiação da luz halógena com o comprimento de onda de 400 a 500nm (HL), luz emitida por diodo com comprimento de onda de 460 de 480 (LED) e laser de diodo (DL) de alta intensidade e comprimento de onda de 810nm, em dentes humanos extraídos. Inicialmente investigou-se a variação de temperatura superficial através da termografia de infravermelho e a temperatura do interior da câmara pulpar por meio de termopares em incisivos inferiores humanos, quando submetidos ao clareamento dental com peróxido de hidrogênio a 35% nas cores vermelha (HP) e verde (HPM) irradiados por: HL e LED. Quatro grupos (n=10) foram divididos de acordo com o gel clareador e a fonte de luz. Os resultados foram submetidos à análise de variância e teste de Tukey (p < 0,05). Os valores médios e desvios padrão do aumento de temperatura dentro da câmara pulpar com a HL foram de 4.4 ± 2.1 °C para HP, e 4.5 ± 1.2 °C para HPM; enquanto que nos grupos usando LED, foram 1.4 ± 0.3 °C para HP, e 1.5 ± 0.2 °C para HPM. Para todas as temperaturas superficiais a variação máxima dos grupos irradiados com HL foi 6.5 ± 1.5 °C para HP, e 7.5 ± 1.1 °C usando HPM; enquanto para os grupos usando LED, foram 2.8 ± 0.7 °C usando HP, e 3 ± 0.8 °C para HPM. Não houve diferença estatística entre o aumento da temperatura pulpar e superficial entre os grupos usando os diferentes géis (p < 0,05). As médias de temperatura foram significativamente maiores para os grupos usando HL quando comparados com aqueles irradiados com LED (p < 0,05). Ainda foi investigada a variação de temperatura superficial e assim determinado o tempo de demora para ser atingida a variação crítica de temperatura...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this in vitro study was to evaluate the variation of temperature and Knoop microhardness on enamel surface during the bleaching process whith 35% hydrogen peroxide under irradiation by halogen light whit the wavelength of 400 to 500nm (HL), LED whit the wavelength of 460 to 480nm and high intensity diode laser LED whit the wavelength of 810nm (LD) on extracted human teeth. Initially were investigated the variation of surface temperature (infrared thermography) and the temperature of the interior of the pulp chamber (thermocouples) in human mandibular incisors when subjected to dental bleaching with 35% hydrogen peroxide in the colors red (HP) and green(HPM) irradiated by: HL and LED. Four groups (n = 10) were divided according to the bleaching gel and light source. The results were submitted to the analysis of variance and Tukey test (p < 0.05). The mean values and standard deviations of the temperature increase inside the chamber pulp with HL were 4.4 ± 2.1 °C using HP and 4.5 ± 1.2 °C using HPM; while in LED groups, were 1.4 ± 0.3 °C to HP, and 1.5 ± 0.2 °C using HPM. For all surface temperatures, the maximum variation of the groups irradiated with HL was 6.5 ± 1.5 °C to HP and 7.5 ± 1.1 °C using HPM; while for the groups using LED, were 2.8° ± 0.7 °C using HP, and 3 ± 0.8 °C for HPM. There were no statistical difference between the increase of pulp and superficial temperature between groups using the various gels (p < 0.05). Mean temperatures were significantly higher for groups using HL compared with those irradiated with LED (p < 0.05). Was investigated the variation of surface temperature and thus given the time-delay to hit the critical variation of temperature (5.5 °C for the pulp chamber and 10 °C for periodontal). Forty-five human inferior incisors were divided into 3 groups and submitted to dental bleaching using...(Complete abstract, click electronic access below) / Mestre

Page generated in 0.1034 seconds