• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • Tagged with
  • 37
  • 37
  • 21
  • 20
  • 18
  • 18
  • 17
  • 17
  • 14
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comportamento eletromagnetico do solo no dominio da frequencia : tratamento de dados de campo e influencia no desempenho de linhas aereas de transmissão de energia eletrica / Soil electromagnetic behavior in frequency domain : measurement treatment and influence in aerial transmission line performance

Gertrudes, João Bosco 08 May 2005 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-05T22:47:45Z (GMT). No. of bitstreams: 1 Gertrudes_JoaoBosco_M.pdf: 6826873 bytes, checksum: 2b476528549162ae8d62b6920b535fdd (MD5) Previous issue date: 2005 / Resumo: Um dos requisitos necessários para estudos e simulação de fenômenos transitórios em sistemas de energia elétrica (aterramentos, linhas de transmissão, etc) é a modelagem adequada do comportamento eletromagnético do solo. Na literatura, os parâmetros (condutividade e permissividade) são usualmente considerados independentes da freqüência, com condutividade (s) constante, e permissividade (e) que pode ser desprezada (?e << s). Estas aproximações quase-estacionárias, tradicionalmente usadas em sistemas de potência podem acarretar erros consideráveis ou modelos inadequados para altas freqüências e fenômenos transitórios rápidos, por exemplo, associados à descargas atmosféricas, uma vez que esses parâmetros (s, ?e) são fortemente dependentes da freqüência. Portanto, torna-se necessário o conhecimento do comportamento do solo na faixa de freqüência 0 a 2 MHz, faixa na qual se encontra o espectro de freqüência da maior parte dos distúrbios do sistema elétrico. Neste trabalho apresentamos novas medições de campo de parâmetros do solo, com amostras coletadas na região de Cachoeira Paulista/SP. Os parâmetros são calculados na faixa de 100 Hz a 2 MHz de acordo com os procedimentos de medição em campo e validação propostos Portela em 1997. São também apresentados procedimentos para minimização da dispersão inerente das medições de campo: identificação das componentes de freqüência dos sinais medidos na amostra através de Transformada de Fourier e uso de filtros adequados para filtragem de ¿ruídos¿. Estes procedimentos são necessários para medição das amplitudes e defasagem entre sinais de tensão e corrente injetados na amostra, na componente de primeira harmônica, dados fundamentais para levantamento dos parâmetros do solo. Para evidenciar a importância da correta modelagem do solo em função da freqüência é feito um estudo comparativo da influência dos parâmetros do solo no desempenho de uma linha de transmissão (LT) trifásica, simples, 440 kV, idealmente transposta, considerando modelo de solo com dependência na freqüência versus modelo de solo a parâmetros constantes (abordagem usual) / Abstract: One of the essential requirements for studies and adequate simulation of transient phenomena in power systems (transmission lines, grounding systems, etc) is the adequate representation of ground effect. Most used procedures assume that the ground may be considered frequency independent, having a constant conductivity (s) and an electric permittivity (e) that can be neglected (?e << s). These three assumptions are quite far from reality and can originate an inadequate soil model for some applications, especially, fast transients phenomena involving atmospheric discharges. It is necessary to have a proper knowledge of soil electromagnetic behaviour in a reasonably wide frequency range, typically from 0 to 2 MHz. In this work we present some procedure to measure, analyze and model the soil electromagnetic behaviour (conductivity s and permittivity e) in the frequency domain, with results obtained in ten soil samples collected at Cachoeira Paulista, Brazil southeast region / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
12

Analise da correta modelagem da transposição em linhas de transmissão no dominio da frequencia / Analysis of transmission line transposition correct modeling on frequency domain

Elguera Flores, Alexander Vladimir 16 November 2006 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-10T17:05:14Z (GMT). No. of bitstreams: 1 ElgueraFlores_AlexanderVladimir_M.pdf: 2442597 bytes, checksum: c3718bb5135d22cdcdf2a22c0c313ed1 (MD5) Previous issue date: 2006 / Resumo: É usual utilizar a transposição das fases nas linhas de transmissão com o intuito de diminuir o desequilíbrio de tensão e corrente existente. Na freqüência fundamental uma linha de transmissão pode ser considerada idealmente transposta, mas normalmente nos estudos de transitórios eletromagnéticos e nos estudos de qualidade de energia as linhas também são representadas como se fossem idealmente transpostas. Para freqüência fundamental é adequado tratar uma linha como idealmente transposta, mas isto não pode ser generalizado para toda a gama de freqüência dos fenômenos transitórios. No presente trabalho foi analisado o erro de se tratar uma linha como idealmente transposta para toda a faixa de freqüências, especificamente até 10 kHz. Uma análise teórica foi implementada identificando o desequilíbrio entre as fases considerando uma linha idealmente transposta e considerando uma linha com trechos de transposição real. A dependência da freqüência dos parâmetros elétricos da linha de transmissão foi adequadamente representada / Abstract: It is usual to use the phase transposition in transmission line aiming to decrease the existing voltage and current unbalance. In fundamental frequency a transmission line can be considered ideally transposed, but normally in the electromagnetic transients and quality energy studies the lines also are represented as if they were ideally transposed. For fundamental frequency it is correct to treat a line as ideally transposed, but this cannot be generalized for the entire frequency range of transient phenomena. In the present work it was analyzed the error of treating transmission line as ideally transposed for all frequency range, specifically up to 10 kHz. A theoretical analysis was implemented identifying the unbalances between the phases considering the transmission line ideally transposed and considering the transmission line with its actual transposition sections. The frequency dependence of transmission line parameters was properly represented. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
13

Modelo de linha de transmissão de circuito duplo trifasico utilizando parametros dependentes da frequencia

Prado, Afonso Jose do 03 August 2018 (has links)
Orientadores : Jose Pissolato Filho, Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-03T03:51:05Z (GMT). No. of bitstreams: 1 Prado_AfonsoJosedo_D.pdf: 3301034 bytes, checksum: 6bebc98c6390b0b744ee507f1ec31840 (MD5) Previous issue date: 2002 / Doutorado
14

Simulação computacional de descargas atmosfericas em estruturas de proteção visando analises de compatibilidade eletromagnetica

Caixeta, Geraldo Peres 24 April 2000 (has links)
Orientador: Jose Pissolato Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-31T17:20:27Z (GMT). No. of bitstreams: 1 Caixeta_GeraldoPeres_D.pdf: 2409891 bytes, checksum: a8425bfafab58cad646fe61ee714acfa (MD5) Previous issue date: 2000 / Resumo: Este trabalho apresenta o estudo da proteção contra descargas atmosféricas através da simulação computacional do transitório de corrente e do campo eletromagnético resultante. Foi necessário o desenvolvimento de uma nova expressão analítica de cálculo do campo eletromagnético (em coordenadas Cartesianas) devido à generalidade das possíveis configurações de uma estrutura. O processo de simulação é composto de quatro fases seqüenciais, as quais foram incluídas em um mesmo programa de computador, escrito em linguagem Fortran. Na primeira fase, a corrente de retomo de uma descarga atmosférica foi modelada como uma linha de transmissão disposta na vertical, ligando a fonte (nuvem) à terra (ou à uma estrutura de proteção). Na segunda fase, a estrutura de proteção foi modelada como sendo constituída de cabos interconectados em geometrias quaisquer, conectada ao canal do raio e á malha de aterramento. Na terceira fase, a malha de aterramento foi modelada também como sendo constituída de cabos interconectados. Na última fase, foi aplicada a expressão de cálculo do campo eletromagnético resultante do transitório de corrente de todo o processo mencionado. Na simulação da expressão de cálculo do campo, cada segmento dos cabos (ou linhas) foi considerado como um pequeno dipolo e o método das imagens foi adotado. A técnica TLM (Transmission Line Modelling) mostrou ser a melhor opção na simulação do transitório de corrente, uma vez que para cada cabo (considerado como urna linha de transmissão), foi possível adotar essa técnica em apenas uma dimensão. Este artificio não é possível em outras técnicas numéricas, como em diferenças finitas, em elementos finitos ou no método dos momentos, sendo nestes casos, necessária a discretização de todo o espaço, além de incorrer em problemas de condições de contorno. Na simulação do campo eletromagnético, foi adotada a técnica de diferenças finitas na nova expressão desenvolvida. Uma grande vantagem de se poder trabalhar com a expressão analítica, é o fato de não se ter que discretizar todo o espaço em volta do sistema simulado, podendo obter resultados de campos em pontos específicos do sistema de coordenadas Cartesianas / Abstract: This work presents the study of protection against lightning through current transitory coniputational simulation and electromagnetic field results. The development of a new ana1ytical expression of calculation for the electromagnetic field was necessary (in Cartesian coordinates) due to the generality of the possible configurations of a structure. The process of simulation is composed of four phases, which were included in the same computer program, written in the Fortran language. In the first phase, the lightning return current Was modeled as a transmission line arranged in the vertical axis, connecting the source (cloud) to the earth (or to a protection structure). In the second phase, the protection structure was modeled as cables interconnected in any geometry, connected to the lightning channel and then to the ground mesh. In the third phase, the ground mesh Was also modeled as interconnected cables. In the last phase, the electromagnetic field calcuIation expression of the transitory of current of the whole process mentioned Was applied. In the simulation of the expression of the field calculation each segment ofthe cables (or lines) was considered as small dipoles and the image method was adopted. Transmission Line Modeling TLM showed to be the best option in the current transitory simulation, once for each cable (considered as a transmission tine), which pennitted the adoption of that technique in one dimension. This artífice canoot be used in other numeric techniques, for example in the tinite differences method. In tinite elements, or the Moment method, the discretization of alI the space is necessary, although problems of contour conditions occur. In the simulation of the electromagnetic field, the tinite differences were adopted with a new developed expression. The advantage of this solution is to work with the analytical expressions and the fact oí not having to completely discretize the space around the simulated system / Doutorado / Engenharia Eletrica / Doutor em Engenharia Elétrica
15

Estudo experimental de transitórios eletromagnéticos em sistemas de aterramento elétrico devidos a pulsos de descargas atmosféricas

CARVALHO, Lorena de Fátima Pinheiro de 29 May 2015 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-26T12:54:55Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoExperimentalTransitorios.pdf: 13678161 bytes, checksum: 780cae26691a9124afb06d9d60cf88e2 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-26T13:16:25Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoExperimentalTransitorios.pdf: 13678161 bytes, checksum: 780cae26691a9124afb06d9d60cf88e2 (MD5) / Made available in DSpace on 2017-01-26T13:16:25Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoExperimentalTransitorios.pdf: 13678161 bytes, checksum: 780cae26691a9124afb06d9d60cf88e2 (MD5) Previous issue date: 2015-05-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, é apresentado um estudo sobre o comportamento transitório e de regime estacionário de sistemas de aterramento quando submetidos a surtos com forma de onda de uma descarga atmosférica. As análises dos sistemas de aterramento foram feitas por meio de dados obtidos através de experimentos realizados em campo e de simulações numéricas baseadas no método das diferenças finitas aplicado para solucionar as equações de Maxwell no domínio do tempo. Nas simulações numéricas, o setup experimental (hastes, cabos, resistor e sinal injetado) e os parâmetros eletromagnéticos do solo e Vácuo (condutividade, permissividade elétrica e permeabilidade magnética) foram modelados numericamente. Observou-se boa concordância entre os sinais medidos durante os testes experimentais e os seus respectivos sinais obtidos numericamente. Esta concordância entre os sinais transitórios medidos e simulados foi obtida tomando-se determinados cuidados técnicos ao se conceber o setup experimental. Tais cuidados técnicos, que normalmente não são postos de forma explícita na literatura, são devidamente abordados e discutidos nesta dissertação. / In this dissertation, we present a study on the transient and steady-state behaviors of grounding systems when subjected to surges with the waveform of a lightning discharge. The analyses of grounding systems were made using data obtained through experiments conducted in the field and numerical simulations based on the finite-difference method applied to solve Maxwell’s equations in the time domain. In numerical simulations, the experimental setup (rods, cables, resistor and injected signal) and the electromagnetic parameters (conductivity, permittivity and magnetic permeability) of soil and vacuum were modeled numerically. There was good agreement between the measured signals during the experimental tests and their respective signals obtained numerically. This agreement between measured and simulated transient signals was obtained by taking certain technical precautions when designing the experimental setup. Such technical precautions, which are usually not explicitly mentioned in technical literature, are properly addressed and discussed in this dissertation.
16

Desenvolvimento e implementação de gerador de surto e sua aplicação na análise numérico-experimental do comportamento transitório de sistemas de aterramento.

ARAÚJO, Ramon Cristian Fernandes 21 September 2015 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-02-10T18:57:29Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-14T15:02:21Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) / Made available in DSpace on 2017-02-14T15:02:21Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_DesenvolvimentoImplementacaoGerador.pdf: 7993868 bytes, checksum: 33fa33f123f54fd3e73540b41d5b35e3 (MD5) Previous issue date: 2015-09-21 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, são apresentadas em detalhes, as etapas do projeto e construção de um gerador de surto de tensão com base em normas internacionalmente estabelecidas (IEC 61000-4-5). Os dois sinais de saída implementados possuem formas de onda características de surtos devidos às descargas atmosféricas primeira e subsequente, respectivamente. Ainda, seus parâmetros obedecem aos valores padronizados pelas normas IEC 60060-1 e IEEE Std-4. A fim de validar o gerador de surto construído, foram analisados os comportamentos transitório e estacionário de diversos sistemas de aterramento quando submetidos a descargas atmosféricas, utilizando o referido gerador como fonte do sinal de injeção. Os sistemas de aterramento foram analisados mediante experimentos em campo, sendo que cada experimento foi reproduzido numericamente através do método FDTD. Baixos erros percentuais foram obtidos entre os sinais medidos durante os experimentos e os sinais numéricos correspondentes. Isso, aliado ao fato de que os aterramentos analisados se comportaram conforme o esperado na literatura, valida o gerador de surto construído neste trabalho. / In this work, the design and construction steps of a voltage surge generator are detailed based on established international standards (IEC 61000-4-5). The waveforms of the two output signals implemented are representative of surges due to the first and subsequent lightning strokes, respectively. Also, their parameters meet the requirements imposed by the standards IEC 60060-1 and IEEE Std-4. In order to validate the surge generator, it was analyzed the transient and steady-state behaviors of several grounding systems when subjected to lightning strokes, using the developed generator as the source of the injection signal. The grounding systems were analyzed by field experiments, and each experiment was reproduced numerically using the FDTD method. Low percentage errors were obtained between the signals measured during the field experiments and the corresponding numerical signals. Moreover, the analyzed grounding systems behaved as expected in literature. Those two facts validade the surge generator built in this work.
17

Análise dos parâmetros elétricos e transitórios eletromagnéticos de linhas de transmissão compostas por torres com altura elevada / Analysis of the electrical parameters and electromagnetic transients of transmission lines consisting of towers with high height

Pinto, André Jinno Gomes, 1983- 04 July 2011 (has links)
Orientador: José Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-18T03:00:37Z (GMT). No. of bitstreams: 1 Pinto_AndreJinnoGomes_M.pdf: 60896723 bytes, checksum: 8ce23cc18a981b5042b135acfc03ec42 (MD5) Previous issue date: 2011 / Resumo: As redes de transmissão de energia elétrica estão entre as grandes contribuições que a engenharia ofereceu à civilização moderna. Se tornando aparentes, pelas expressivas linhas de transmissão de alta tensão apoiadas sobre elevadas torres de aço que cruzam o território nacional em todas as direções. No corrente trabalho tem-se por objetivo tratar das alternativas não-convencionais de transmissão de energia elétrica. Comparando o desempenho dessas novas estruturas com o comportamento das estruturas atualmente utilizadas no sistema de transmissão convencional. Para tal são descritos alguns dados da atual configuração do sistema de transmissão nacional. Ademais, breves descrições técnicas serão apresentadas sobre os principais componentes de linhas de transmissão convencionais, tais como: condutores múltiplos, isoladores e anéis anticorona. Tais definições serão introduzidas com o âmbito de proporcionar uma maior familiaridade com o tema em estudo. Uma análise minuciosa é traçada no cálculo dos parâmetros elétricos na frequência, seguido de um estudo dos transitórios eletromagnéticos no domínio do tempo. Causados por sinais de tensão aplicados a entrada das linhas de transmissão / Abstract: The transmission of electric energy is among the great contributions that engineering offered to modern civilization. Becoming apparent, by the expressive lines of high voltage transmission supported on large steel towers that crisscross the country in all directions. In the current work has been aimed at dealing with alternative non-conventional electric power transmission. Comparing the performance of these new structures with the behavior of the structures currently used in conventional transmission system. For such thing are described some of the current configuration of the national transmission system. In addition, brief technical descriptions are presented on the main components of conventional transmission lines, such as multiple conductors, insulators and anti-corona rings. Such definitions will be introduced to the scope of providing a greater familiarity with the subject under study. A detailed analysis is plotted on the calculation of electrical parameters on frequency, followed by a study of electromagnetic transient time domain. Caused by voltage signals applied to the input of the transmission lines / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
18

Estudo do comportamento das tensões transitorias em malhas de aterramento diante descargas atmosfericas / Study of the behavior of the transient voltages in grounding grids caused by lightning

Marin Mesa, Henry Ramon 11 April 2005 (has links)
Orientador: Jose Pissolato Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-06T10:45:47Z (GMT). No. of bitstreams: 1 MarinMesa_HenryRamon_M.pdf: 775188 bytes, checksum: d44b6096c03070dff5fb491bb2b0d7dd (MD5) Previous issue date: 2005 / Resumo: Este trabalho apresenta uma análise computacional usando a técnica numérica TLM (Transmission Line Method) do comportamento das tensões transitórias em sistemas de aterramento, quando submetidas a fenômenos impulsivos do tipo descargas atmosféricas. É apresentada uma revisão bibliográfica sobre o tema e os diferentes métodos numéricos usados para modelar sistemas de aterramento. A técnica numérica TLM é apresentada, assim como, as equações para a determinação dos parâmetros usados nas simulações e o fluxograma do programa computacional desenvolvido. O programa foi escrito em Fortran e validado comparando os resultados obtidos com simulações e testes experimentais publicados por outros autores. Com o objetivo de obter o comportamento das tensões transitórias sobre diferentes situações, foi estudada a influência de alguns parâmetros no comportamento transitório das malhas de aterramento / Abstract: This work, by using the TLM (Transmission Line Method) numeric technique, presents a computational analysis of the transitory tensions behavior in grounding systems, when submitted to impulsive phenomena of the atmospheric discharge type. A bibliographical revision on the theme and the different numeric methods used for modelling grounding systems, including the TLM numeric technique, are explained, as well as the equations for the determination of the parameters used in the simulations and the flowchart of the software developed. The program written in Fortran was validated comparing simulations and experimental tests published by other authors. For the purpose of obtaining the transitory tensions behavior in different situations, we studied the influence of some parameters in the transitory behavior of grounding meshes / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
19

Analise de sensibilidade de parametros eletricos de linhas de transmissão no dominio da frequencia / Sensitivity analysis of electrical transmission line parameters in frequency domain

Pinheiro, Michel Gonçalves 17 November 2005 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e Computação / Made available in DSpace on 2018-08-08T12:51:45Z (GMT). No. of bitstreams: 1 Pinheiro_MichelGonA§alves_M.pdf: 1094075 bytes, checksum: 1c9863b695ee82d8312c89c87f94085b (MD5) Previous issue date: 2005 / Resumo: Este trabalho apresenta uma extensa análise de sensibilidade dos parâmetros elétricos longitudinais e transversais de uma linha de transmissão trifásica em função da freqüência. Uma linha real de 440 kV foi utilizada como base para as análises. Considerando determinadas hipóteses simplificadoras, foram calculados os parâmetros elétricos da linha: resistência, indutância e capacitância no domínio da freqüência. Esses parâmetros foram apresentados em termos das parcelas das matrizes primitivas, das matrizes reduzidas e componentes modais. Na análise de sensibilidade variaram-se as seguintes características da linha: diâmetros dos cabos pára-raios, diâmetros dos condutores fase, altura dos condutores, distância horizontal entre as fases, espaçamento vertical dos sub-condutores dos feixes das fases externas. Para cada variação observou-se o comportamento dos parâmetros elétricos em função da freqüência, em termos das parcelas das matrizes primitivas e em termos dos modos. Também foi observado o fator de aterramento e foram estimados os aumentos de potência natural em função das variações realizadas. As linhas com elevada potência natural (LPNE) foram avaliadas no âmbito da análise efetivada / Abstract: In this work a large sensitivity analysis of longitudinal and transversal electrical parameters of a three-phase transmission line in frequency domain was performed. An actual 440 kV transmission line was used as reference in the analysis. Considering some simplified hypothesis, electrical parameters, as resistance, inductance and capacitance, were evaluated in frequency domain. Those parameters were presented in terms of parcels of primitive matrices and reduced matrices in phase modal domain. An extensive sensitivity analysis was performed and the following line caracteristics were varied: ground wires diameter, phase conductors diameter, height of conductors, horizontal distance among phases and vertical spacing within external phases bending. For each line caracteristic, the performance of electrical parameters in frequency domain, in terms of primitive and modal matrices was observed. Also, it was observed the ground factor and it was estimated the increases on natural power. Using of High Natural Power Lines was studied and related to variations of line geometry / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
20

Sobre a determinação de parametros de geradores sincronos para estudos de comportamento dinamico de sistemas eletricos / On the determination of parameters synchronous generators for the study of dynamic behavior of power systems

Peqquena Suni, Juan Carlos 15 August 2018 (has links)
Orientador: Ernesto Ruppert Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T03:55:20Z (GMT). No. of bitstreams: 1 PeqquenaSuni_JuanCarlos_M.pdf: 1533933 bytes, checksum: dbd348c759114d83f69069e35635591c (MD5) Previous issue date: 2009 / Resumo: Os parâmetros do modelo matemático dinâmico dos geradores síncronos como a resistência elétrica dos enrolamentos de estator por fase, a resistência elétrica do enrolamento de campo, as resistências elétricas dos enrolamentos amortecedores de eixo direto e de eixo em quadratura, as reatâncias de dispersão dos enrolamentos de estator por fase, do enrolamento de campo e dos enrolamentos amortecedores, bem como as reatâncias de magnetização de eixo direto e de eixo em quadratura do gerador são possíveis de serem determinadas, com razoável aproximação, através de ensaios específicos como o ensaio para determinação da reatância de Potier, o ensaio de curto-circuito trifásico brusco e os ensaios de rejeição de carga. Neste trabalho discute-se o problema da determinação de parâmetros do gerador síncrono auxiliado pela realização de simulações dinâmicas usando o software Matlab/Simulink e a sua biblioteca SimPowerSystems para determinação de parâmetros de um gerador de pólos lisos e de um gerador de pólos salientes através de ensaios de medição da reatância síncrona de eixo direto, ensaio de Potier, ensaio de curto-circuito brusco e ensaio de rejeição de carga. Diversos resultados e conclusões são apresentados usando os parâmetros padronizados mostrados explicitamente por Krause em seu importante livro publicado em 1986. Trata-se de um trabalho que tem finalidades didática e tecnológica de discutir essa questão / Abstract: The synchronous generator dynamic mathematical model parameters like the per phase stator winding electrical resistance, the field winding resistance, the direct and quadrature damping winding resistances, the field winding leakage reactance, the per phase stator winding leakage reactance, the damping winding leakage reactances, and direct and quadrature magnetizing reactances are possible to be determined with some accuracy through specific tests like the Potier reactance determination, the sudden short-circuit test and the load rejection tests. This work is addressed to the problem of salient poles and cylincrical rotor synchronous generator parameters determination aided by the use of dynamic simulations implemented with the Matlab/Simulink package using its SimPowerSystems library. Some results and conclusions about the parameters determination are presented using the standardized and fundamental parameters as shown in the Krause book published in 1986. This paper has both didactic and technological subjects and it is addressed to discuss several aspects on the real parameters determination activities / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Page generated in 0.0913 seconds