• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • Tagged with
  • 37
  • 37
  • 21
  • 20
  • 18
  • 18
  • 17
  • 17
  • 14
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Resposta transitória no domínio do tempo de uma linha de transmissão trifásica considerando uma nova implementação do efeito pelicular = Time domain transient response analysis of three-phase transmission line considering a new skin effect model / Time domain transient response analysis of three-phase transmission line considering a new skin effect model

Monteiro, José Humberto Araújo, 1981- 05 September 2014 (has links)
Orientadores: José Pissolato Filho, Eduardo Coelho Marques da Costa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T04:23:41Z (GMT). No. of bitstreams: 1 Monteiro_JoseHumbertoAraujo_D.pdf: 2599049 bytes, checksum: 247f68cef0523b44c3d1e9c69dc48119 (MD5) Previous issue date: 2014 / Resumo: Este trabalho apresenta o desenvolvimento de um modelo de linha de transmissão trifásica utilizando uma nova implementação do efeito pelicular, além do estudo da resposta transitória obtida a partir do referido modelo quando surtos de manobra são simulados. A metodologia tradicionalmente utilizada para o cálculo da impedância interna de cabos sólidos cilíndricos faz uso das funções de Bessel, o que a torna complexa. A metodologia descrita por Gatous é tão precisa quanto a metodologia que utiliza as funções de Bessel e possui a vantagem de ser mais simples, visto que a solução final é um somatório cuja precisão depende da frequência estudada. O modelo desenvolvido neste trabalho emprega a metodologia de Gatous em uma linha de transmissão trifásica, cujos modos de propagação independentes são obtidos a partir da aplicação da matriz de Clarke. Para validar a metodologia de Gatous, foram calculadas a resistência e a indutância interna de cabos com raios variados em uma ampla faixa de frequências. Os resultados foram comparados aos obtidos a partir da metodologia tradicional. A metodologia de Gatous reproduziu com precisão a variação da impedância interna com a frequência. Para avaliar o funcionamento do modelo de linha de transmissão trifásico no domínio do tempo, um caso base foi estabelecido. Uma linha de transmissão trifásica de 69kV, circuito simples, foi submetida a chaveamentos de carga em duas situações distintas: chaveamento sendo executado no ponto de cruzamento com o zero da tensão e; chaveamento no ponto de 90° da tensão. Os transitórios de tensão e corrente foram obtidos a partir do modelo elaborado e comparados com os resultantes do software de análise de transitórios ATP. Os resultados alcançados reproduzem com fidelidade o comportamento transiente descrito pelo software supracitado / Abstract: This paper presents the development of a three-phase transmission line model using a new skin effect calculation and its transient response when some switching surges are applied to it. The methodology commonly used to calculate the internal impedance of solid conductors with cylindrical cross sectional area employs Bessel functions, which makes it a hard task to accomplish. Gatous, in his doctoral work, presented a new method to calculate skin effect impedance as accurate as Bessel¿s methodology with advantage of simplicity, whereas that final solution is an algebraic sum whose precision depends of frequency studied. The transmission line model developed in this work utilizes Gatous¿s method for skin effect impedance calculation in a three-phase transmission line, whose independent modes of propagation are obtained from the application of Clarke's matrix. In order to validate the mentioned methodology, internal resistances and inductances of cables with different size radii were calculated for a wide range of frequencies. The results were compared with those obtained through the traditional method, reproducing correctly the variation of the internal impedance with frequency. A base case was established to evaluate the operation of the three-phase transmission line in the time-domain model. A 69kV three-phase transmission line, single circuit, was subjected to switching load in two distinct situations: switching at zero crossing voltage and switching at voltage peak. Voltage and current transients were obtained from the developed model and compared with those derived from transient analysis software ATP. The results faithfully reproduced the transient behavior described by the above software / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
32

Analise do desempenho dinamico de geradores sincronos conectados em redes de distribuição de energia eletrica / Dynamic performance of synchronous generators connected to electric power distribution systems

Abreu, Lisias Vieira Lima de 27 June 2005 (has links)
Orientadores: Luiz Carlos Pereira da Silva, Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T14:34:40Z (GMT). No. of bitstreams: 1 Abreu_LisiasVieiraLimade_M.pdf: 4055307 bytes, checksum: 5b3f4d39e414e1d305ec71b68f93ed3f (MD5) Previous issue date: 2005 / Resumo: Nesta dissertação de mestrado, apresenta-se um estudo detalhado sobre o desempenho dinâmico de geradores síncronos conectados em redes de distribuição de energia elétrica frente a grandes perturbações. Estudos paramétricos são realizados para investigar a influência de di-versos fatores na resposta transitória do gerador. Os fatores analisados são tempo de eliminação da falta, carregamento do sistema, níveis de curto-circuito no ponto de conexão entre o sistema de distribuição e a rede de subtransmissão, relação X/R das linhas de distribuição e constante de inércia dos geradores. Adicionalmente, propõe-se a utilização de índices numéricos que permitem visualizar de forma sistemática os resultados dos estudos paramétricos assim como determinar quais são as barras mais apropriadas para a instalação de geradores síncronos con-siderando o desempenho dinâmico do sistema / Abstract: In this dissertation, it is presented a detailed study about the dynamic performance of synchronous generators connected to distribution networks during large disturbances. Parame-tric studies are conducted in order to determine the influence of several factors on the transient response of the generator. The analyzed factors are fault clea / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
33

Implementação do religamento monopolar adaptativo rápido baseado na assinatura harmônica de tensão no simulador digital em tempo real (RTDS) / Implementation of fast adaptive single-phase reclosing based on measurement of harmonic content in the real-time digital simulator (RTDS)

Dias, Ozenir Farah da Rocha, 1988- 27 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-27T00:34:34Z (GMT). No. of bitstreams: 1 Dias_OzenirFarahdaRocha_M.pdf: 5023742 bytes, checksum: b0fe9b9418551d927583a884fbec6e92 (MD5) Previous issue date: 2015 / Resumo: Este trabalho apresenta a implementação de um esquema de religamento monopolar adaptativo rápido baseado na medição do conteúdo harmônico da tensão da fase aberta nas extremidades da linha de transmissão. O objetivo principal deste esquema é controlar e reduzir o tempo compreendido entre a abertura e o religamento da fase em falta, como também bloquear a manobra em caso de faltas permanentes. O esquema proposto foi implementado em um relé de distância e um medidor de conteúdo harmônico. O método está baseado na identificação do instante de extinção da corrente de arco secundário para casos de faltas transitórias. Já para faltas permanentes é implementado o bloqueio da manobra automática e a abertura tripolar do disjuntor da linha protegida. A medição do conteúdo harmônico foi feita primeiramente utilizando um medidor de qualidade de energia comercial, que realiza a medição do conteúdo harmônico de acordo com a norma IEC 61000-4-3. Em seguida, foi utilizado outro método de medição do conteúdo harmônico, chamado de filtro de medição do conteúdo harmônico rápido, elaborado dentro do Simulador Digital em Tempo Real (RTDS). O sistema de transmissão utilizado foi modelado no RTDS e seus dados são dados reais do sistema interligado nacional (SIN). As faltas monofásicas transitórias foram simuladas utilizando o modelo de arco do próprio RTDS. Já para falta permanente utilizou-se uma resistência de 1 'ômega'. O esquema foi avaliado através de testes variando o ponto de aplicação do defeito e o valor da corrente de arco secundário / Abstract: This work presents the implementation of a scheme of fast adaptive single-phase reclosing based on measuring the voltage harmonic content at the opened faulty phase terminals. The main objective of this scheme is to control and to reduce the time between opening and reclosing of the phase in fault, and also to block the maneuver in case of permanent faults. The proposed scheme is implemented in a distance relay and a harmonic content meter. The method is based in the identification of the secondary arc current extinction moment for transient faults cases. For permanent faults an automatic blocking followed by circuit-breaker three-phase opening is implemented. The measurement of harmonic content was made initially using a commercial power quality meter, which performs the harmonic content measurement according to IEC 61000-4-3 standard. Another harmonic content measurement method was tested, the fast harmonic content filter measurement, elaborated within the real-time digital simulator (RTDS). The transmission system used was modeled on RTDS and the data corresponds to an actual Brazilian 500 kV system. To represent the transient single-phase fault it was used RTDS arc model. The permanent fault was modeled with an 1'ômega' resistance. The scheme was evaluated by varying the fault application point and the secondary arc current value / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
34

Segmentação, classificação e detecção de novas classes de eventos em oscilografias de redes de distribuição de energia elétrica

Lazzaretti, André Eugenio 27 February 2015 (has links)
CAPES / Este trabalho apresenta novas abordagens para duas das etapas fundamentais relacionadas com análise automática de oscilografias de redes de distribuição: a detecção dos instantes transitórios e a sua classificação. Para comparação e validação dos métodos são utilizadas duas bases de dados, sendo uma delas formada por dados simulados no aplicativo Alternative Transient Program e outra contendo dados reais de oscilógrafos instalados em uma rede de distribuição de energia elétrica. Os dados reais apresentam um conjunto de eventos relevante para as análises aqui propostas, principalmente por conter uma gama variada de eventos, incluindo transitórios decorrentes de descargas atmosféricas. Com relação à detecção de transitórios (segmentação de oscilografias), foram testados os métodos atualmente propostos na literatura, os quais contemplam Filtro de Kalman, Transformada Wavelet Discreta e Modelos Autorregressivos, além de serem propostas duas novas técnicas baseadas no Operador de Energia de Teager e Representação de Dados Utilizando Vetores Suporte. Demonstra-se que, tanto para dados simulados quanto para dados reais, o método de detecção baseado na Representação de Dados utilizando Vetores Suporte aponta para um melhor desempenho global no processo de detecção. Com relação à classificação automática de oscilografias, propõe-se uma nova abordagem incluindo um estágio dedicado à detecção de padrões não inseridos no aprendizado prévio do classificador, denominados de novidades, além da própria classificação multiclasse normalmente empregada para diferenciar múltiplas classes conhecidas a priori. São testadas abordagens utilizando a detecção de novidades e classificação multiclasse em estágios simultâneos e subsequentes, com base nos classificadores X-Médias, K-Vizinhos-Mais-Próximos e Representação de Dados Utilizando Vetores Suporte com diferentes formulações, além do próprio classificador multiclasse baseado em Máquinas de Vetor Suporte. Adicionalmente, é proposto um tratamento aos padrões considerados como novidades, com o intuito de fornecer informações ao especialista sobre as similaridades existentes entre os padrões desse conjunto. Para realizar esse processo, optou-se por utilizar modelos de agrupamento automático. Os resultados finais, principalmente para a base de dados incluindo eventos reais, mostram que é possível obter um desempenho de classificação relevante (acima de 80%) para cada um dos estágios do processo de classificação proposto, o qual inclui a detecção de novidades, a classificação multiclasse e o processamento de padrões classificados como novidades (agrupamento automático). / This work presents new approaches for two of the fundamental steps in automatic waveform analysis in electrical distribution systems: transient time detection and its classification. Two datasets were used to compare and validate the proposed methods. The first is composed by simulated waveforms, by using the Alternative Transient Program, while the second is formed by real data from a monitoring system developed for overhead distribution power lines. The real data present a set of relevant events for the analysis proposed here, mainly due to the variety of events, including lightning-related transients. Regarding transient detection (waveform segmentation), the experiments involve usual segmentation methods, such as Kalman filtering, standard Discrete Wavelet Transform, and autoregressive models, besides two new techniques based on the Teager Energy Operator and Support Vector Data Description. The results obtained on both simulated and real world data demonstrate that the method based on Support Vector Data Description outperforms other methods in the transient identification task. Regarding the automatic waveform classification, a new approach including the detection of classes not defined in the training stage (called novelties) is presented. Also, the classifier is able to discriminate among multiple known classes, normally defined as multi-class classification. Two different approaches are compared, by using multi-class classification and novelty detection in two subsequent stages and in a simultaneous way. The following classifiers were assessed: X-Means, K-Nearest-Neighbors, and Support Vector Data Description with different formulations, besides the Support Vector Machine for multi-class classification. Furthermore, a technique for the post-processing of the novelties is presented, in order to provide some useful information for the experts, regarding possible similarities in the novelty set. To accomplish this task, automatic clustering methods were used. The final results, especially for the dataset with real examples, show that it is possible to obtain a relevant classification performance (above 80%) in each one of the three stages of the classification process: multi-class classification, novelty detection, and the post-processing applied to the novelties (automatic clustering).
35

Segmentação, classificação e detecção de novas classes de eventos em oscilografias de redes de distribuição de energia elétrica

Lazzaretti, André Eugenio 27 February 2015 (has links)
CAPES / Este trabalho apresenta novas abordagens para duas das etapas fundamentais relacionadas com análise automática de oscilografias de redes de distribuição: a detecção dos instantes transitórios e a sua classificação. Para comparação e validação dos métodos são utilizadas duas bases de dados, sendo uma delas formada por dados simulados no aplicativo Alternative Transient Program e outra contendo dados reais de oscilógrafos instalados em uma rede de distribuição de energia elétrica. Os dados reais apresentam um conjunto de eventos relevante para as análises aqui propostas, principalmente por conter uma gama variada de eventos, incluindo transitórios decorrentes de descargas atmosféricas. Com relação à detecção de transitórios (segmentação de oscilografias), foram testados os métodos atualmente propostos na literatura, os quais contemplam Filtro de Kalman, Transformada Wavelet Discreta e Modelos Autorregressivos, além de serem propostas duas novas técnicas baseadas no Operador de Energia de Teager e Representação de Dados Utilizando Vetores Suporte. Demonstra-se que, tanto para dados simulados quanto para dados reais, o método de detecção baseado na Representação de Dados utilizando Vetores Suporte aponta para um melhor desempenho global no processo de detecção. Com relação à classificação automática de oscilografias, propõe-se uma nova abordagem incluindo um estágio dedicado à detecção de padrões não inseridos no aprendizado prévio do classificador, denominados de novidades, além da própria classificação multiclasse normalmente empregada para diferenciar múltiplas classes conhecidas a priori. São testadas abordagens utilizando a detecção de novidades e classificação multiclasse em estágios simultâneos e subsequentes, com base nos classificadores X-Médias, K-Vizinhos-Mais-Próximos e Representação de Dados Utilizando Vetores Suporte com diferentes formulações, além do próprio classificador multiclasse baseado em Máquinas de Vetor Suporte. Adicionalmente, é proposto um tratamento aos padrões considerados como novidades, com o intuito de fornecer informações ao especialista sobre as similaridades existentes entre os padrões desse conjunto. Para realizar esse processo, optou-se por utilizar modelos de agrupamento automático. Os resultados finais, principalmente para a base de dados incluindo eventos reais, mostram que é possível obter um desempenho de classificação relevante (acima de 80%) para cada um dos estágios do processo de classificação proposto, o qual inclui a detecção de novidades, a classificação multiclasse e o processamento de padrões classificados como novidades (agrupamento automático). / This work presents new approaches for two of the fundamental steps in automatic waveform analysis in electrical distribution systems: transient time detection and its classification. Two datasets were used to compare and validate the proposed methods. The first is composed by simulated waveforms, by using the Alternative Transient Program, while the second is formed by real data from a monitoring system developed for overhead distribution power lines. The real data present a set of relevant events for the analysis proposed here, mainly due to the variety of events, including lightning-related transients. Regarding transient detection (waveform segmentation), the experiments involve usual segmentation methods, such as Kalman filtering, standard Discrete Wavelet Transform, and autoregressive models, besides two new techniques based on the Teager Energy Operator and Support Vector Data Description. The results obtained on both simulated and real world data demonstrate that the method based on Support Vector Data Description outperforms other methods in the transient identification task. Regarding the automatic waveform classification, a new approach including the detection of classes not defined in the training stage (called novelties) is presented. Also, the classifier is able to discriminate among multiple known classes, normally defined as multi-class classification. Two different approaches are compared, by using multi-class classification and novelty detection in two subsequent stages and in a simultaneous way. The following classifiers were assessed: X-Means, K-Nearest-Neighbors, and Support Vector Data Description with different formulations, besides the Support Vector Machine for multi-class classification. Furthermore, a technique for the post-processing of the novelties is presented, in order to provide some useful information for the experts, regarding possible similarities in the novelty set. To accomplish this task, automatic clustering methods were used. The final results, especially for the dataset with real examples, show that it is possible to obtain a relevant classification performance (above 80%) in each one of the three stages of the classification process: multi-class classification, novelty detection, and the post-processing applied to the novelties (automatic clustering).
36

Metodos analiticos para analise de geradores de indução conectados em redes de distribuição de energia eletrica / Analytical methods for analysis of induction generators connected to eletric power distribution systems

Pavani, Ahda Pionkoski Grilo 21 May 2008 (has links)
Orientador: Walmir de Freitas Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T01:48:23Z (GMT). No. of bitstreams: 1 Pavani_AhdaPionkoskiGrilo_D.pdf: 1263424 bytes, checksum: a9bc6ef797b8137921a5148c04dc44f7 (MD5) Previous issue date: 2008 / Resumo: Esta tese apresenta o desenvolvimento de diversos métodos analíticos para análise de geradores de indução com rotor em gaiola de esquilo conectados em redes de distribuição de energia elétrica. Foram desenvolvidas metodologias para investigar as seguintes questões técnicas: análise de estabilidade de geradores de indução frente a grandes perturbações; análise de estabilidade de geradores de indução frente a pequenas perturbações; determinação dos valores ótimos dos resistores utilizados por diferentes técnicas de energização de geradores de indução e determinação das correntes de curto-circuito fornecidas por geradores de indução durante faltas desequilibradas. Os métodos analíticos desenvolvidos foram validados por meio de comparações dos resultados obtidos através da aplicação das fórmulas propostas com aqueles obtidos através de simulações computacionais empregando-se típicos programas de análise de sistemas de potência e/ou testes experimentais. Os resultados obtidos comprovam que os métodos analíticos propostos são suficientemente precisos para avaliar o comportamento dos geradores de indução com rotor em gaiola de esquilo, reduzindo o esforço usualmente necessário na realização de análise através de simulações computacionais / Abstract: This thesis presents the development of analytical methods for analysis of squirrel-cage induction generators connected to distribution systems. It was developed analytical methods for evaluation of the following technical issues: large-disturbance stability analysis of induction generators; small-disturbance stability analysis of induction generators; determination of optimum resistances employed by energization devices of induction generators and development of formulas to determine the short-circuit currents of induction generators during unbalanced faults. The analytical methods developed were validated by comparing the results obtained by the proposed formulas with those determined by computational simulations employing typical programs of analysis of power systems and/or experimental tests. The results showed that the proposed analytical methods are enough accurate to evaluate the behavior of the squirrel-cage induction generators, reducing the usually necessary effort for analysis by computational simulations / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
37

Modelo reduzido de linhas de transmissão para transitorios eletromagneticos : aplicação de propriedades complexas / Condensed transmission line model to electromagnetic transient phenomena : use of complex properties

Paz, Marcos de Araujo 18 November 2005 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação / Made available in DSpace on 2018-08-07T13:37:43Z (GMT). No. of bitstreams: 1 Paz_MarcosdeAraujo_D.pdf: 6127820 bytes, checksum: 21f6dc485bcf097846769f086c2362ad (MD5) Previous issue date: 2005 / Resumo: O objetivo deste trabalho é contribuir para o estudo de linhas de transmissão e o desenvolvimento de modelos de linhas voltados a programas do tipo EMTP. O trabalho desenvolvido consiste em aproveitar as propriedades e semelhanças dos modos não homopolares de propagação das linhas de transmissão, sejam elas idealmente transpostas ou que apresentem plano de simetria vertical. Por meio de manipulações da matriz de transformação fase-modo-fase através do uso de vetores ortogonais e elementos complexos no domínio modal, pode-se reduzir a dimensão dos vetores de estado. O procedimento proposto é direcionado às modelagens que utilizam transformação fase-modo-fase na determinação das variáveis de estado (corrente e tensão) nas linhas de transmissão. Os recursos usados levam a uma redução tanto em número de operações por iteração quanto em alocação de estados, otimizando o procedimento de cá1culo e aumentando a velocidade de simulação no processamento. A economia computacional que o procedimento proposto proporciona pode ser usada em ferramentas de simulação em tempo real / Abstract: The research objective is to contribute with the study of the transmission line and the development of line models in EMTP-type programs. The proposed model takes advantage of some similarities between non homopolar modes, applying orthogonal vectors and complex number theory to manipulate the state vectors in modal domain reducing the state vectors dimension. The proposed procedure is aimed to the modelling that use phase-mode-phase transformation in the determination of state variables (current and voltage) in transmission lines. The resources used lead to a reduction both in the number of operations per iteration and state allocation, optimizing the procedure and increasing the processing simulation speed. The computational economy, which the proposed procedure provide, can be applied to real-time simulation tools / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica

Page generated in 1.4061 seconds