• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 11
  • Tagged with
  • 32
  • 32
  • 32
  • 21
  • 19
  • 18
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Développement d'un prototype d'une plateforme de photométrie par fibre optique sans fils

Ransford, Étienne 06 July 2023 (has links)
Titre de l'écran-titre (visionné le 26 juin 2023) / L'étude du cerveau est cruciale à la compréhension de son fonctionnement et pour l'avancement en médecine. Il existe une multitude de techniques pour visualiser ou mesurer l'activité du cerveau afin d'étudier ses mécanismes. Pour étudier une population spécifique de neurones, la photométrie par fibre optique est souvent préférée puisqu'elle permet de mesurer l'activité de seulement un groupe de neurones spécifiquement marqué par des indicateurs calciques au choix. La photométrie par fibre optique est une technique d'imagerie souvent utilisée chez les rongeurs (habituellement des souris) pour mesurer l'activité neuronale d'un groupe spécifique de neurones lors d'expérimentations in vivo en attachant une fibre optique directement à la région du cerveau à l'étude. Le désavantage de la photométrie par fibre optique conventionnelle est que la fibre optique qui est branchée directement à la tête de la souris doit être acheminée à l'extérieur de l'environnement de test, ce qui limite les déplacements de la souris et lui cause un certain stress. Ce travail propose une preuve de concept d'un système de photométrie par fibre optique sans fil ayant des performances à la hauteur des systèmes commerciaux existants avec fibre reliée à l'extérieur de l'environnement de test. Le design de cette preuve de concept repose sur la conception de circuits analogiques ainsi que le développement d'algorithmes de traitement de signal. Le système conçu dans ce travail offre une lecture de signal avec une référence au point isosbestique avec une puissance équivalent de bruit de 5.39fW/√ Hz, un niveau de bruit équivalent, ou même plus bas que les systèmes commerciaux disponibles. Ce système est sans fil, rechargeable et peut prendre des mesures pendant une durée de 210 minutes (3 heures et 30 minutes). Il contient aussi un lock-in amplifier numérique permettant de réduire le poids et la dimension du système tout en augmentant de 30dB le SNR du signal de photométrie. Les éléments du système de photométrie de ce travail ont été testés sur des souris in vivo lors d'une expérimentation sur l'activité neuronale de l'hypothalamus latéral (LHA) en réponse à un stimulus aversif. / The study of the brain is crucial to its understanding and the pursuit of medical research. There exists a multitude of techniques used to visualize or measure brain activity in order to study its working mechanisms. To study a specific group of neurons, the preferred method is fiber photometry because it allows to monitor a specific group of neurons that have been marked by a chosen calcium indicator. Fiber photometry is an imaging technique often used on rodents (usually mice) to monitor neural activity in a specific type of neuron while performing in vivo experimentation by directly implanting a probing optical fiber to the brain region under study. The drawback of conventional fiber photometry is that the optical fiber implanted in the subject's head needs to be connected outside the test environment, which limits its movements and creates unnecessary stress on the mouse. This work proposes a proof of concept of a wireless fiber photometry system with performance worthy of current existing cabled commercial systems. The design of this proof of concept rests on the conception of analog circuits and the development of signal processing algorithms. The system designed in this work offers a reading with an isosbestic point reference with a noise equivalent power of 5.39fW/√ Hz, a noise level equivalent, or even lower than available commercial products. This system is wireless, rechargeable and can make measurements for a period of 210 minutes (3 hours and 30 minutes). It also contains a digital lock-in amplifier, allowing to reduce the size and weight of the system while still gaining a 30dB increase in SNR in the photometry reading. The various elements of this system have been tested in live mice during in vivo testing of the neural activity of the lateral hypothalamus (LHA) in response to an aversive stimulus.
2

Développement d'un capteur de déformation MEMS sans fil

Merdassi, Adel January 2011 (has links)
Il y a un besoin de mesures de vibration, tel que dans l'automobile pour le contrôle actif du bruit acoustique. Les microsystèmes électromécaniques (MEMS) et les technologies sans fils sont des technologies de plus en plus répandues pour l'implémentation de capteurs. Ce projet vise donc le développement de capteurs de déformation en utilisant une solution sans fil pour l'acquisition des mesures de la vibration, avec les technologies MEMS. Ce projet de recherche utilise la technologie des systèmes RFID passifs pour la communication, intégrée avec un transducteur de déformation MEMS pour la mesure. Le capteur consiste en une antenne reliée à un transducteur MEMS capacitif par l'entremise d'une ligne de transmission avec des discontinuités. Les déformations de la structure sur laquelle le capteur est fixé sont traduites en changement de capacité du transducteur, ce qui engendre un retard dans le signal réfléchi par l'antenne. Une étude de l'état de l'art des principes de communication et de transduction a permis de comparer les avantages et inconvénients des approches. Une modélisation analytique faite sur différents types de transduction a conduit à une combinaison optimale faisant intervenir un transducteur type capacitif. Pour atteindre une taille du capteur de l'ordre du centimètre, le système travaille à une fréquence micro-onde fixée à 24,125 GHz. Un dispositif fût alors conçu, incluant la ligne de transmission avec des discontinuités pour l'identification du capteur ainsi que le transducteur capacitif avec peignes interdigités et ressorts en silicium. La conception d'un tel capteur permet d'aboutir à une sensibilité de 11ps/[epsilon] avec une bonne linéarité sur une plage de mesure [0..2500[micro][epsilon]]. Un procédé de microfabrication du transducteur MEMS est aussi proposé, ainsi qu'une approche pour la fabrication pour les éléments RF sur un substrat d'alumine et leur intégration.
3

Medical applications of radio frequency wireless devices /

Prabhu, Krishna. January 2003 (has links)
Thèse (Ph.D.)--Université Laval, 2003. / Bibliogr.: f. 142-144. Publié aussi en version électronique.
4

Amélioration de la sécurité et de la fiabilité des systèmes de communication sans fil

Amirzadeh, Ahmadreza 24 April 2018 (has links)
Dans ce mémoire, de nouvelles approches ont été introduites pour concevoir les systèmes de communication fiables, Section 1, et sécurisées, Section 2, où les codes LDPC ont été choisis comme schéma de codage principal. Ce mémoire comprend deux sections : Section 1 : Les codes LDPC réguliers et irréguliers sont définis et différents décodeurs basés sur l’échange de message de décisions fermes et souples sont introduits. Par la suite, quelques définitions, comme le seuil des codes LDPC utilisant l’évolution de la densité de probabilité (ou la propagation de croyance), l’écart multiplicatif et les distributions de degrés de noeuds de parité et de noeuds de variable, sont énoncées. Par après, ces concepts préliminaires sont utilisés pour concevoir des ensembles de code LDPC irréguliers approchant la capacité du canal à l’aide de programmation linéaire et d’un algorithme génétique. Section 2 : Une méthode est introduite pour l’amélioration du secret dans ce genre de système. Cette méthode fonctionne sur la base de demande de retransmission de paquets d’information. Selon cette approche, lorsque le récepteur ne peut pas converger vers le bon message, une demande de retransmission est envoyée. Au lieu d’envoyer le paquet entier dans le cas d’une défaillance à la sortie du décodeur du destinataire, la retransmission des sous-paquets est explorée. Le système proposé dans cette phase est appelé protocole HARQ-Granulaire Adaptatif (AG-HARQ). Il essaie de réduire au minimum le taux requis pour un décodage réussi par les parties légitimes tout en augmentant la sécurité en minimisant les fuites d’information vers un espion éventuel. En outre, pour améliorer encore le niveau de sécurité dans la méthode AG-HARQ proposée, le schéma de contamination d’erreur intra-trame (IntraEC) et le schéma de contamination d’erreur inter-trame (InterEC) sont utilisés en conjonction avec cette méthode. Cette combinaison permet un haut niveau de sécurité dans le système de communication sans fil. / In this memoir, new approaches have been introduced for designing reliable, Section 1, and secure, Section 2, communication systems where the LDPC codes have been chosen as the principal coding scheme. This memoir comprises two sections: Section 1: Regular and irregular LDPC codes are defined and different message passing decoders based on hard and soft decisions are introduced. Afterward, some definitions like the threshold of LDPC codes using Density Evolution (or Belief Propagation), the Multiplicative Gap, and the check node and variable node degree distributions are explained in detail. Later, these preliminary concepts are used to design the channel capacity approaching Irregular LDPC codes combining Genetic Algorithm and Linear Programming. Section 2: A new scheme is introduced for secrecy enhancement for these systems. This method is based on feedback retransmission requests. With this approach, when the intended recipient cannot converge to the right message, a retransmission request is sent back to the transmitter. The retransmission of the sub-packets, instead of sending the whole packet in the case of failure at the intended recipient’s decoder output, is explored in detail. Our proposed scheme is called Adaptive Granular Hybrid Automatic Repeat reQuest (AG-HARQ) protocol, which tries to minimize the required rate for successful decoding of the legitimate parties while amplifying the privacy by minimizing the information leakage to a wiretapper. In addition, to further improve the security level of the proposed AG-HARQ method, Intra-frame error contamination (IntraEC) and Inter-frame error contamination (InterEC) schemes are used in conjunction with this method. This combination can provide a high level of security in wireless communication systems.
5

High-performance wireless interface for implant-to-air communications

Bahrami, Hadi 23 April 2018 (has links)
Nous élaborons une interface cerveau-machine (ICM) entièrement sans fil afin de fournir un système de liaison directe entre le cerveau et les périphériques externes, permettant l’enregistrement et la stimulation du cerveau pour une utilisation permanente. Au cours de cette thèse, nous explorons la modélisation de canal, les antennes implantées et portables en tant que propagateurs appropriés pour cette application, la conception du nouveau système d’un émetteur-récepteur UWB implantable, la conception niveau système du circuit et sa mise en oeuvre par un procédé CMOS TSMC 0.18 um. En plus, en collaboration avec Université McGill, nous avons conçu un réseau de seize antennes pour une détection du cancer du sein à l’aide d’hyperfréquences. Notre première contribution calcule la caractérisation de canal de liaison sans fil UWB d’implant à l’air, l’absorption spécifique moyennée (ASAR), et les lignes directrices de la FCC sur la densité spectrale de puissance UWB transmis. La connaissance du comportement du canal est nécessaire pour déterminer la puissance maximale permise à 1) respecter les lignes directrices ANSI pour éviter des dommages aux tissus et 2) respecter les lignes directrices de la FCC sur les transmissions non autorisées. Nous avons recours à un modèle réaliste du canal biologique afin de concevoir les antennes pour l’émetteur implanté et le récepteur externe. Le placement des antennes est examiné avec deux scénarios contrastés ayant des contraintés de puissance. La performance du système au sein des tissus biologiques est examinée par l’intermédiaire des simulations et des expériences. Notre deuxième contribution est dédiée à la conception des antennes simples et à double polarisation pour les systèmes d’enregistrement neural sans fil à bande ultra-large en utilisant un modèle multicouches inhomogène de la tête humaine. Les antennes fabriquées à partir de matériaux flexibles sont plus facilement adaptées à l’implantation ; nous étudions des matériaux à la fois flexibles et rigides et examinons des compromis de performance. Les antennes proposées sont conçues pour fonctionner dans une plage de fréquence de 2-11 GHz (ayant S11-dessous de -10 dB) couvrant à la fois la bande 2.45 GHz (ISM) et la bande UWB 3.1-10.6 GHz. Des mesures confirment les résultats de simulation et montrent que les antennes flexibles ont peu de dégradation des performances en raison des effets de flexion (en termes de correspondance d’impédance). Finalement, une comparaison est réalisée entre quatre antennes implantables, couvrant la gamme 2-11 GHz : 1) une rigide, à la polarisation simple, 2) une rigide, à double polarisation, 3) une flexible, à simple polarisation et 4) une flexible, à double polarisation. Dans tous les cas une antenne rigide est utilisée à l’extérieur du corps, avec une polarisation appropriée. Plusieurs avantages ont été confirmés pour les antennes à la polarisation double : 1) une taille plus petite, 2) la sensibilité plus faible aux désalignements angulaires, et 3) une plus grande fidélité. Notre troisième contribution fournit la conception niveau système de l’architecture de communication sans fil pour les systèmes implantés qui stimulent simultanément les neurones et enregistrent les réponses de neurones. Cette architecture prend en charge un grand nombre d’électrodes (> 500), fournissant 100 Mb/s pour des signaux de stimulation de liaison descendante, et Gb/s pour les enregistrements de neurones de liaison montante. Nous proposons une architecture d’émetteur-récepteur qui partage une antenne ultra large bande, un émetteur-récepteur simplifié, travaillant en duplex intégral sur les deux bandes, et un nouveau formeur d’impulsions pour la liaison montante du Gb/s soutenant plusieurs formats de modulation. Nous présentons une démonstration expérimentale d’ex vivo de l’architecture en utilisant des composants discrets pour la réalisation les taux Gb/s en liaison montante. Une bonne performance de taux d’erreur de bit sur un canal biologique à 0,5, 1 et 2 Gb/s des débits de données pour la télémétrie de liaison montante (UWB) et 100 Mb/s pour la télémétrie en liaison descendante (bande 2.45 GHz) est atteinte. Notre quatrième contribution présente la conception au niveau du circuit d’un dispositif d’émission en duplex total qui est présentée dans notre troisième contribution. Ce dispositif d’émission en duplex total soutient les applications d’interfaçage neural multimodal et en haute densité (les canaux de stimulant et d’enregistrement) avec des débits de données asymétriques. L’émetteur (TX) et le récepteur (RX) partagent une seule antenne pour réduire la taille de l’implant. Le TX utilise impulse radio ultra-wide band (IR-UWB) basé sur une approche alliant des bords, et le RX utilise un nouveau 2.4 GHz récepteur on-off keying (OOK).Une bonne isolation (> 20 dB) entre le trajet TX et RX est mis en oeuvre 1) par mise en forme des impulsions transmises pour tomber dans le spectre UWB non réglementé (3.1-7 GHz), et 2) par un filtrage espace-efficace du spectre de liaison descendante OOK dans un amplificateur à faible bruit RX. L’émetteur UWB 3.1-7 GHz peut utiliser soit OOK soit la modulation numérique binaire à déplacement de phase (BPSK). Le FDT proposé offre une double bande avec un taux de données de liaison montante de 500 Mbps TX et un taux de données de liaison descendante de 100 Mb/s RX, et il est entièrement en conformité avec les standards TSMC 0.18 um CMOS dans un volume total de 0,8 mm2. Ainsi, la mesure de consommation d’énergie totale en mode full duplex est de 10,4 mW (5 mW à 100 Mb/s pour RX, et de 5,4 mW à 500 Mb/s ou 10,8 PJ / bits pour TX). Notre cinquième contribution est une collaboration avec l’Université McGill dans laquelle nous concevons des antennes simples et à double polarisation pour les systèmes de détection du cancer du sein à l’aide d’hyperfréquences sans fil en utilisant un modèle multi-couche et inhomogène du sein humain. Les antennes fabriquées à partir de matériaux flexibles sont plus facilement adaptées à des applications portables. Les antennes flexibles miniaturisées monopôles et spirales sur un 50 um Kapton polyimide sont conçus, en utilisant high frequency structure simulator (HFSS), à être en contact avec des tissus biologiques du sein. Les antennes proposées sont conçues pour fonctionner dans une gamme de fréquences de 2 à 4 GHz. Les mesures montrent que les antennes flexibles ont une bonne adaptation d’impédance dans les différentes positions sur le sein. De Plus, deux antennes à bande ultralarge flexibles 4 × 4 (simple et à double polarisation), dans un format similaire à celui d’un soutien-gorge, ont été développés pour un système de détection du cancer du sein basé sur le radar. / We are working on a fully wireless brain-machine-interface to provide a communication link between the brain and external devices, enabling recording and stimulating the brain for permanent usage. In this thesis we explore channel modeling, implanted and wearable antennas as suitable propagators for this application, system level design of an implantable UWB transceiver, and circuit level design and implementing it by TSMC 0.18 um CMOS process. Also, in a collaboration project with McGill University, we designed a flexible sixteen antenna array for microwave breast cancer detection. Our first contribution calculates channel characteristics of implant-to-air UWB wireless link, average specific absorption rate (ASAR), and FCC guidelines on transmitted UWB power spectral density. Knowledge of channel behavior is required to determine the maximum allowable power to 1) respect ANSI guidelines for avoiding tissue damage and 2) respect FCC guidelines on unlicensed transmissions. We utilize a realistic model of the biological channel to inform the design of antennas for the implanted transmitter and the external receiver. Antennas placement is examined under two scenarios having contrasting power constraints. Performance of the system within the biological tissues is examined via simulations and experiments. Our second contribution deals with designing single and dual-polarization antennas for wireless ultra-wideband neural recording systems using an inhomogeneous multi-layer model of the human head. Antennas made from flexible materials are more easily adapted to implantation; we investigate both flexible and rigid materials and examine performance trade-offs. The proposed antennas are designed to operate in a frequency range of 2–11 GHz (having S11 below -10 dB) covering both the 2.45 GHz (ISM) band and the 3.1–10.6 GHz UWB band. Measurements confirm simulation results showing flexible antennas have little performance degradation due to bending effects (in terms of impedance matching). Finally, a comparison is made of four implantable antennas covering the 2-11 GHz range: 1) rigid, single polarization, 2) rigid, dual polarization, 3) flexible, single polarization and 4) flexible, dual polarization. In all cases a rigid antenna is used outside the body, with an appropriate polarization. Several advantages were confirmed for dual polarization antennas: 1) smaller size, 2) lower sensitivity to angular misalignments, and 3) higher fidelity. Our third contribution provides system level design of wireless communication architecture for implanted systems that simultaneously stimulate neurons and record neural responses. This architecture supports large numbers of electrodes (> 500), providing 100 Mb/s for the downlink of stimulation signals, and Gb/s for the uplink neural recordings. We propose a transceiver architecture that shares one ultra-wideband antenna, a streamlined transceiver working at full-duplex on both bands, and a novel pulse shaper for the Gb/s uplink supporting several modulation formats. We present an ex-vivo experimental demonstration of the architecture using discrete components achieving Gb/s uplink rates. Good bit error rate performance over a biological channel at 0.5, 1, and 2 Gbps data rates for uplink telemetry (UWB) and 100 Mbps for downlink telemetry (2.45 GHz band) is achieved. Our fourth contribution presents circuit level design of the novel full-duplex transceiver (FDT) which is presented in our third contribution. This full-duplex transceiver supports high-density and multimodal neural interfacing applications (high-channel count stimulating and recording) with asymmetric data rates. The transmitter (TX) and receiver (RX) share a single antenna to reduce implant size. The TX uses impulse radio ultra-wide band (IR-UWB) based on an edge combining approach, and the RX uses a novel 2.4-GHz on-off keying (OOK) receiver. Proper isolation (> 20 dB) between the TX and RX path is implemented 1) by shaping the transmitted pulses to fall within the unregulated UWB spectrum (3.1-7 GHz), and 2) by spaceefficient filtering (avoiding a circulator or diplexer) of the downlink OOK spectrum in the RX low-noise amplifier. The UWB 3.1-7 GHz transmitter can use either OOK or binary phase shift keying (BPSK) modulation schemes. The proposed FDT provides dual band 500-Mbps TX uplink data rate and 100 Mbps RX downlink data rate, and it is fully integrated into standard TSMC 0.18 um CMOS within a total size of 0.8 mm2. The total measured power consumption is 10.4 mW in full duplex mode (5 mW at 100 Mbps for RX, and 5.4 mW at 500 Mbps or 10.8 pJ/bit for TX). Our fifth contribution is a collaboration project with McGill University which we design single and dual-polarization antennas for wireless ultra-wideband breast cancer detection systems using an inhomogeneous multi-layer model of the human breast. Antennas made from flexible materials are more easily adapted to wearable applications. Miniaturized flexible monopole and spiral antennas on a 50 um Kapton polyimide are designed, using a high frequency structure simulator (HFSS), to be in contact with biological breast tissues. The proposed antennas are designed to operate in a frequency range of 2–4 GHz (with reflection coefficient (S11) below -10 dB). Measurements show that the flexible antennas have good impedance matching while in different positions with different curvature around the breast. Furthermore, two flexible conformal 4×4 ultra-wideband antenna arrays (single and dual polarization), in a format similar to that of a bra, were developed for a radar-based breast cancer detection system.
6

Design and Analysis of GFDM-Based Wireless Communication Systems

Wang, Yanpeng 03 August 2021 (has links)
Le multiplexage généralisé par répartition en fréquence (GFDM), une méthode de traitement par blocs de modulation multiporteuses non orthogonales, est une candidate prometteuse pour les technologies de forme d'onde pour les systèmes sans fil au-delà de la cinquième génération (5G). La capacité du GFDM à ajuster de manière flexible la taille du bloc et le type de filtres de mise en forme des impulsions en fait une méthode appropriée pour répondre à plusieurs exigences importantes, comme une faible latence, un faible rayonnement hors bande (OOB) et des débits de données élevés. En appliquant aux systèmes GFDM la technique des systèmes à entrées multiples et sorties multiples (MIMO), la technique de MIMO massif ou des codes de contrôle de parité à faible densité (LDPC), il est possible d'améliorer leurs performances. Par conséquent, l'étude de ces systèmes combinés sont d'une grande importance théorique et pratique. Dans cette thèse, nous étudions les systèmes de communication sans fil basés sur le GFDM en considérant trois aspects. Tout d'abord, nous dérivons une borne d'union sur le taux d'erreur sur les bits (BER) pour les systèmes MIMO-GFDM, technique qui est basée sur des probabilités d'erreur par paires exactes (PEP). La PEP exacte est calculée en utilisant la fonction génératrice de moments(MGF) pour les détecteurs à maximum de vraisemblance (ML). La corrélation spatiale entre les antennes et les erreurs d'estimation de canal sont prises en compte dans l'environnement de canal étudié. Deuxièmement, les estimateurs et les précodeurs de canal de faible complexité basés sur une expansion polynomiale sont proposés pour les systèmes MIMO-GFDM massifs. Des pilotes sans interférence sont utilisés pour l'estimation du canal basée sur l'erreur quadratique moyenne minimale(MMSE) pour lutter contre l'influence de la non-orthogonalité entre les sous-porteuses dans le GFDM. La complexité de calcul cubique peut être réduite à une complexité d'ordre au carré en utilisant la technique d'expansion polynomiale pour approximer les inverses de matrices dans l'estimation MMSE conventionnelle et le précodage. De plus, nous calculons les limites de performance en termes d'erreur quadratique moyenne (MSE) pour les estimateurs proposés, ce qui peut être un outil utile pour prédire la performance des estimateurs dans la région de Eₛ/N₀ élevé. Une borne inférieure de Cramér-Rao(CRLB) est dérivée pour notre modèle de système et agit comme une référence pour les estimateurs. La complexité de calcul des estimateurs de canal proposés et des précodeurs et les impacts du degré du polynôme sont également étudiés. Enfin, nous analysons les performances de la probabilité d'erreur des systèmes GFDM combinés aux codes LDPC. Nous dérivons d'abord les expressions du ratio de vraisemblance logarithmique (LLR) initiale qui sont utilisées dans le décodeur de l'algorithme de somme de produits (SPA). Ensuite, basé sur le seuil de décodage, nous estimons le taux d'erreur de trame (FER) dans la région de bas E[indice b]/N₀ en utilisant le BER observé pour modéliser les variations du canal. De plus, une borne inférieure du FER du système est également proposée basée sur des ensembles absorbants. Cette borne inférieure peut agir comme une estimation du FER dans la région de E[indice b]/N₀ élevé si l'ensemble absorbant utilisé est dominant et que sa multiplicité est connue. La quantification a également un impact important sur les performances du FER et du BER. Des codes LDPC basés sur un tableau et construit aléatoirement sont utilisés pour supporter les analyses de performances. Pour ces trois aspects, des simulations et des calculs informatiques sont effectués pour obtenir des résultats numériques connexes, qui vérifient les méthodes proposées. / $8 372162\u $a Generalized frequency division multiplexing (GFDM) is a block-processing based non-orthogonal multi-carrier modulation scheme, which is a promising candidate waveform technology for beyond fifth-generation (5G) wireless systems. The ability of GFDM to flexibly adjust the block size and the type of pulse-shaping filters makes it a suitable scheme to meet several important requirements, such as low latency, low out-of-band (OOB) radiation and high data rates. Applying the multiple-input multiple-output (MIMO) technique, the massive MIMO technique, or low-density parity-check (LDPC) codes to GFDM systems can further improve the systems performance. Therefore, the investigation of such combined systems is of great theoretical and practical importance. This thesis investigates GFDM-based wireless communication systems from the following three aspects. First, we derive a union bound on the bit error rate (BER) for MIMO-GFDM systems, which is based on exact pairwise error probabilities (PEPs). The exact PEP is calculated using the moment-generating function (MGF) for maximum likelihood (ML) detectors. Both the spatial correlation between antennas and the channel estimation errors are considered in the investigated channel environment. Second, polynomial expansion-based low-complexity channel estimators and precoders are proposed for massive MIMO-GFDM systems. Interference-free pilots are used in the minimum mean square error (MMSE) channel estimation to combat the influence of non-orthogonality between subcarriers in GFDM. The cubic computational complexity can be reduced to square order by using the polynomial expansion technique to approximate the matrix inverses in the conventional MMSE estimation and precoding. In addition, we derive performance limits in terms of the mean square error (MSE) for the proposed estimators, which can be a useful tool to predict estimators performance in the high Eₛ/N₀ region. A Cramér-Rao lower bound (CRLB) is derived for our system model and acts as a benchmark for the estimators. The computational complexity of the proposed channel estimators and precoders, and the impacts of the polynomial degree are also investigated. Finally, we analyze the error probability performance of LDPC coded GFDM systems. We first derive the initial log-likelihood ratio (LLR) expressions that are used in the sum-product algorithm (SPA) decoder. Then, based on the decoding threshold, we estimate the frame error rate (FER) in the low E[subscript b]/N₀ region by using the observed BER to model the channel variations. In addition, a lower bound on the FER of the system is also proposed based on absorbing sets. This lower bound can act as an estimate of the FER in the high E[subscript b]/N₀ region if the absorbing set used is dominant and its multiplicity is known. The quantization scheme also has an important impact on the FER and BER performances. Randomly constructed and array-based LDPC codes are used to support the performance analyses. For all these three aspects, software-based simulations and calculations are carried out to obtain related numerical results, which verify our proposed methods.
7

User-interactive wirelessly-communicating “smart” textiles made from multimaterial fibers

Gorgutsa, Stepan 24 April 2018 (has links)
En raison de la nature intime des interactions homme-textiles (essentiellement, nous sommes entourés par les textiles 24/7 - soit sous la forme de vêtements que nous portons ou comme rembourrage dans nos voitures, maisons, bureaux, etc.), les textiles intelligents sont devenus des plates-formes de plus en plus attrayantes pour les réseaux de capteurs innovants biomédicaux, transducteurs, et des microprocesseurs dédiés à la surveillance continue de la santé. En même temps, l'approche commune dans le domaine des textiles intelligents consiste en l'adaptation de la microélectronique planaire classique à une sorte de substrat souple. Cela se traduit souvent par de mauvaises propriétés mécaniques et donc des compromis au niveau du confort et de l'acceptation des usagers, qui à leur tour peuvent probablement expliquer pourquoi ces solutions émergent rarement du laboratoire et, à l'exception de certains cas très spécifiques, ne soit pas utilisés dans la vie de tous les jours. Par ailleurs, nous assistons présentement à un changement de paradigme au niveau de l'informatique autonome classique vers le concept de calculs distribués (ou informatique en nuage). Dans ce cas, la puissance de calcul du nœud individuel ou d'un dispositif de textile intelligent est moins importante que la capacité de transmettre des données à l'Internet. Dans ce travail, je propose une nouvelle approche basée sur l'intégration de polymère, verre et métal dans des structures de fibres miniaturisées afin de réaliser des dispositifs de textiles intelligents de prochaine génération avec des fonctionnalités de niveau supérieur (comme la communication sans fil, la reconnaissance tactile, les interconnexions électriques) tout en ayant une forme minimalement envahissante. Tout d'abord, j'étudie différents modèles d'antennes compatibles avec la géométrie des fibres et des techniques de fabrication. Ensuite, je démontre expérimentalement que ces antennes en fibres multi-matériaux peuvent être intégrées dans les textiles lors d’un processus standard de fabrication de textiles. Les tests effectués sur ces textiles ont montré que, pour les scénarios «sur-corps et hors-corps», les propriétés émissives en termes de perte de retour (S11), le patron (diagramme) de radiation, l'efficacité (gain), et le taux d'erreur binaire (TEB) sont directement comparables à des solutions classiques rigides. Ces antennes sont adéquates pour les communications à courte portée des applications de communications sans fil ayant un débit de données de Mo/s (méga-octets par seconde) (via protocoles Bluetooth et IEEE 802.15.4 à la fréquence de 2,4 GHz). Des simulations numériques de taux d'absorption spécifique démontrent également le plein respect des règles de sécurité imposées par Industrie Canada pour les réseaux sans fil à proximité du corps humain. Puisque les matériaux composites de fibres métal-verre-polymère sont fabriqués en utilisant des fibres de silice creuses de diamètre submillimétrique et la technique de dépôt d'argent à l'état liquide, les éléments conducteurs sont protégés de l'environnement et ceci préserve aussi les propriétés mécaniques et esthétiques des vêtements. Cet aspect est confirmé par des essais correspondant aux normes de l'industrie du textile, l'étirement standard et des essais de flexion. De plus, appliquer des revêtements superhydrophobes (WCA = 152º, SA = 6º) permet une communication sans fil sans interruption de ces textiles sous l'application directe de l'eau, même après plusieurs cycles de lavage. Enfin, le prototype de textile intelligent fabriqué interagit avec l'utilisateur à travers un détecteur tactile et transmet les données tactiles à travers le protocole Bluetooth à un smartphone. Cette démonstration valide l’approche des fibres multi-matériaux pour une variété d'applications. / As we are surrounded by textiles 24/7, either in the form of garments that we wear or as upholstery in our cars, homes, offices, etc., textiles are especially attractive platforms for arrays of innovative biomedical sensors, transducers, and microprocessors dedicated, among other applications, to continuous health monitoring. In the same time, the common approach in the field of smart textiles consists in adaptation of conventional planar microelectronics to some kind of flexible substrate, which often results in poor mechanical properties and thus compromises wearing comfort and complicates garment care, which results in low user acceptance. This explains why such solutions rarely emerge from the lab and, with the exception of some very specific cases, cannot be seen in the everyday life. Furthermore, we are currently witnessing a global shift from classical standalone computing to the concept of distributed computation (e.g. so-called thin clients and cloud storage). In this context, the computation power of the individual node or smart textile device in this case, becomes progressively less important than the ability to relay data to the Internet. In this work, I propose a novel approach based on the idea of integration of polymer, glass and metal into miniaturized fiber structures in order to achieve next-generation smart textile devices with higher-level functionalities, such as wireless communication, touch recognition, electrical interconnects, with minimally-invasive attributes. First, I investigate different possible fiber-shaped antenna designs and fabrication techniques. Next, I experimentally demonstrate that such multi-material fiber antennas can be integrated into textiles during standard textile manufacturing process. Tests conducted on these textiles have shown that, for on-body and off-body scenarios, the emissive properties in terms of return loss (S11), radiation pattern, efficiency (gain), and bit-error rate (BER) are directly comparable to classic ‘rigid’ solutions and adequately address short-range wireless communications applications at Mbps data-rates (via Bluetooth and IEEE 802.15.4 protocols at 2.4 GHz frequency). Numerical simulations of the specific absorption rate (SAR) also demonstrate full compliance with safety regulations imposed by Industry Canada for wireless body area network devices. Since metal-glass-polymer fiber composites were fabricated using sub-millimetre hollow-core silica fibers and liquid state silver deposition technique, the conductor elements are shielded against the environment and preserve the mechanical and cosmetic properties of the garments. This is confirmed by the textile industry standard stretching and bending tests. Additionally, applied superhydrophobic coatings (WCA=152º, SA=6º) allow uninterrupted wireless communication of the textiles under direct water application even after multiple washing cycles. Finally, I fabricated a user-interactive and wireless-communicating smart textile prototype, that interacts with the user through capacitive touch-sensing and relays the touch data through Bluetooth protocol to a smartphone. This demonstration validates that the proposed approach based on multi-material fibers is suitable for applications to sensor fabrics and bio-sensing textiles connected in real time to mobile communications infrastructures, suitable for a variety of health and life science applications.
8

High-performance wireless power and data transfer interface for implantable medical devices

Mirbozorgi, Seyed Abdollah January 2015 (has links)
D’importants progès ont été réalisés dans le développement des systèmes biomédicaux implantables grâce aux dernières avancées de la microélectronique et des technologies sans fil. Néanmoins, ces appareils restent difficiles à commercialier. Cette situation est due particulièrement à un manque de stratégies de design capable supporter les fonctionnalités exigées, aux limites de miniaturisation, ainsi qu’au manque d’interface sans fil à haut débit fiable et faible puissance capable de connecter les implants et les périphériques externes. Le nombre de sites de stimulation et/ou d’électrodes d’enregistrement retrouvés dans les dernières interfaces cerveau-ordinateur (IMC) ne cesse de croître afin d’augmenter la précision de contrôle, et d’améliorer notre compréhension des fonctions cérébrales. Ce nombre est appelé à atteindre un millier de site à court terme, ce qui exige des débits de données atteingnant facilement les 500 Mbps. Ceci étant dit, ces travaux visent à élaborer de nouvelles stratégies innovantes de conception de dispositifs biomédicaux implantables afin de repousser les limites mentionnées ci-dessus. On présente de nouvelles techniques faible puissance beaucoup plus performantes pour le transfert d’énergie et de données sans fil à haut débit ainsi que l’analyse et la réalisation de ces dernières grâce à des prototypes microélectroniques CMOS. Dans un premier temps, ces travaux exposent notre nouvelle structure multibobine inductive à résonance présentant une puissance sans fil distribuée uniformément pour alimenter des systèmes miniatures d’étude du cerveaux avec des models animaux en ilberté ainsi que des dispositifs médicaux implantbles sans fil qui se caractérisent par une capacité de positionnement libre. La structure propose un lien de résonance multibobines inductive, dont le résonateur principal est constitué d’une multitude de résonateurs identiques disposés dans une matrice de bobines carrées. Ces dernières sont connectées en parallèle afin de réaliser des surfaces de puissance (2D) ainsi qu’une chambre d’alimentation (3D). La chambre proposée utilise deux matrices de résonateurs de base, mises face à face et connectés en parallèle afin d’obtenir une distribution d’énergie uniforme en 3D. Chaque surface comprend neuf bobines superposées, connectées en parallèle et réailsées sur une carte de circuit imprimé deux couches FR4. La chambre dispose d’un mécanisme naturel de localisation de puissance qui facilite sa mise en oeuvre et son fonctionnement. En procédant ainsi, nous évitons la nécessité d’une détection active de l’emplacement de la charge et le contrôle d’alimentation. Notre approche permet à cette surface d’alimentation unique de fournir une efficacité de transfert de puissance (PTE) de 69% et une puissance délivrée à la charge (PDL) de 120 mW, pour une distance de séparation de 4 cm, tandis que le prototype de chambre complet fournit un PTE uniforme de 59% et un PDL de 100 mW en 3D, partout à l’intérieur de la chambre avec un volume de chambre de 27 × 27 × 16 cm3. Une étape critique avant d’utiliser un dispositif implantable chez les humains consiste à vérifier ses fonctionnalités sur des sujets animaux. Par conséquent, la chambre d’énergie sans fil conçue sera utilisée afin de caractériser les performances d’ une interface sans fil de transmisison de données dans un environnement réaliste in vivo avec positionement libre. Un émetteur-récepteur full-duplex (FDT) entièrement intégré qui se caractérise par sa faible puissance est conçu pour réaliser une interfaces bi-directionnelles (stimulation et enregistrement) avec des débits asymétriques: des taux de tramnsmission plus élevés sont nécessaires pour l’enregistrement électrophysiologique multicanal (signaux de liaison montante) alors que les taux moins élevés sont utilisés pour la stimulation (les signaux de liaison descendante). L’émetteur (TX) et le récepteur (RX) se partagent une seule antenne afin de réduire la taille de l’implant. L’émetteur utilise la radio ultra-large bande par impulsions (IR-UWB) basée sur l’approche edge combining et le RX utilise la bande ISM (Industrielle, Scientifique et Médicale) de fréquence central 2.4 GHz et la modulation on-off-keying (OOK). Une bonne isolation (> 20 dB) est obtenue entre le TX et le RX grâce à 1) la mise en forme les impulsions émises dans le spectre UWB non réglementée (3.1-7 GHz), et 2) le filtrage espace-efficace (évitant l’utilisation d’un circulateur ou d’un diplexeur) du spectre du lien de communication descendant directement au niveau de l’ amplificateur à faible bruit (LNA). L’émetteur UWB 3.1-7 GHz utilise un e modultion OOK ainsi qu’une modulation par déplacement de phase (BPSK) à seulement 10.8 pJ / bits. Le FDT proposé permet d’atteindre 500 Mbps de débit de données en lien montant et 100 Mbps de débit de données de lien descendant. Il est entièrement intégré dans un procédé TSMC CMOS 0.18 um standard et possède une taille totale de 0.8 mm2. La consommation totale d’énergie mesurée est de 10.4 mW (5 mW pour RX et 5.4 mW pour TX au taux de 500 Mbps). / In recent years, there has been major progress on implantable biomedical systems that support most of the functionalities of wireless implantable devices. Nevertheless, these devices remain mostly restricted to be commercialized, in part due to weakness of a straightforward design to support the required functionalities, limitation on miniaturization, and lack of a reliable low-power high data rate interface between implants and external devices. This research provides novel strategies on the design of implantable biomedical devices that addresses these limitations by presenting analysis and techniques for wireless power transfer and efficient data transfer. The first part of this research includes our proposed novel resonance-based multicoil inductive power link structure with uniform power distribution to wirelessly power up smart animal research systems and implanted medical devices with high power efficiency and free positioning capability. The proposed structure consists of a multicoil resonance inductive link, which primary resonator array is made of several identical resonators enclosed in a scalable array of overlapping square coils that are connected in parallel and arranged in power surface (2D) and power chamber (3D) configurations. The proposed chamber uses two arrays of primary resonators, facing each other, and connected in parallel to achieve uniform power distribution in 3D. Each surface includes 9 overlapped coils connected in parallel and implemented into two layers of FR4 printed circuit board. The chamber features a natural power localization mechanism, which simplifies its implementation and eases its operation by avoiding the need for active detection of the load location and power control mechanisms. A single power surface based on the proposed approach can provide a power transfer efficiency (PTE) of 69% and a power delivered to the load (PDL) of 120 mW, for a separation distance of 4 cm, whereas the complete chamber prototype provides a uniform PTE of 59% and a PDL of 100 mW in 3D, everywhere inside the chamber with a chamber size of 27×27×16 cm3. The second part of this research includes our proposed novel, fully-integrated, low-power fullduplex transceiver (FDT) to support bi-directional neural interfacing applications (stimulating and recording) with asymmetric data rates: higher rates are required for recording (uplink signals) than stimulation (downlink signals). The transmitter (TX) and receiver (RX) share a single antenna to reduce implant size. The TX uses impulse radio ultra-wide band (IR-UWB) based on an edge combining approach, and the RX uses a novel 2.4-GHz on-off keying (OOK) receiver. Proper isolation (> 20 dB) between the TX and RX path is implemented 1) by shaping the transmitted pulses to fall within the unregulated UWB spectrum (3.1-7 GHz), and 2) by space-efficient filtering (avoiding a circulator or diplexer) of the downlink OOK spectrum in the RX low-noise amplifier (LNA). The UWB 3.1-7 GHz transmitter using OOK and binary phase shift keying (BPSK) modulations at only 10.8 pJ/bit. The proposed FDT provides dual band 500 Mbps TX uplink data rate and 100 Mbps RX downlink data rate. It is fully integrated on standard TSMC 0.18 nm CMOS within a total size of 0.8 mm2. The total power consumption measured 10.4 mW (5 mW for RX and 5.4 mW for TX at the rate of 500 Mbps).
9

Algorithmes et processeurs temps réel de traitement de signaux neuronaux pour une plateforme optogénétique sans fil

Gagnon-Turcotte, Gabriel 23 April 2018 (has links)
Tableau d'honneur de la Faculté des études supérieures et postdorales, 2015-2016 / L’acquisition des signaux électriques provenant des neurones du cerveau permet aux neurobiologistes de mieux comprendre son fonctionnement. Dans le cadre de ce travail, de nouveaux algorithmes de compression des signaux neuronaux sont conçus et présentés. Ces nouveaux algorithmes sont incorporés dans trois nouveaux dispositifs optogénétiques sans fil miniature capable de stimuler optiquement l’activité neuronale et de transmettre sans fil les biopotentiels captés par plusieurs microélectrodes. Deux de ces systèmes sont capables de compresser les signaux provenant de deux microélectrodes ainsi que de stimuler optiquement via deux diodes électroluminescentes (DEL) haute puissance. Afin de réduire la bande passante des transmetteurs sans fil utilisés, ces deux systèmes sont dotés d’un nouvel algorithme de détection des potentiels d’actions qui génère de meilleurs taux de détection que les algorithmes existants, tout en nécessitant moins de ressources matérielles et de temps de processeur. Un troisième dispositif incorporant les algorithmes de détection et de compression fût conçu. Ce dispositif est le seul système optogénétique sans fil comportant 32 canaux de stimulation optique et 32 canaux d’enregistrement électrophysiologiques en parallèle. Il utilise une nouvelle technique de compression par ondelettes permettant d’augmenter significativement le nombre de canaux sous observation sans augmenter la consommation de l’émetteurrécepteur. Cette nouvelle méthode de compression se distingue des méthodes existantes en atteignant de meilleurs taux de compression tout en permettant de reconstruire les signaux compressés avec une meilleure qualité. Au moment de la rédaction de ce mémoire, il s’agit des premiers dispositifs optogénétiques sans fil à offrir simultanément de la stimulation optique multicanal, de l’enregistrement électrophysiologique multicanal ainsi que de la détection/compression in situ des potentiels d’actions. Grâce à leur design novateur et aux innovations apportées par les nouveaux algorithmes de traitement des signaux, les systèmes conçus sont plus légers et plus compacts que les systèmes précédents, rendant ces dispositifs indispensables afin de mener des expériences sur le cerveau de petits animaux libres de leurs mouvements. Les trois systèmes ont été validés avec grand succès par des expériences in vivo sur des souris transgéniques au Centre de Recherche de l’Institut Universitaire en Santé Mentale de Québec (CRIUSMQ). / The electrical signals acquisition from the brain’s neurons allows neuroscientists to better understand its functioning. In this work, new neural signals compression algorithms are designed and presented. These new algorithms are incorporated into three new miniature optogenetic wireless devices. These devices are capable to optically stimulate neural activity and to wirelessly transmit the biopotentials captured by several microelectrodes. Two of these systems are able to compress the signals from two microelectrodes and to stimulate optically via two high-power LED. Both systems feature a new spike detection algorithm to reduce the bandwidth used by the wireless transceiver. This new spike detection algorithm differs from existing algorithms by achieving better detection rate while using less material resources and processing time. A third device incorporating the detection and compression algorithms was designed. This device is the only optogenetic wireless system including 32 optical stimulation channels and 32 electrophysiological recording channels in parallel. This new system has the ability to compress the neural signals using a new wavelet compression technique that significantly increase the number of channels under observation without increasing the consumption of the wireless transceiver. In particular, this new compression technique differs from the existing wavelet based compression methods by achieving better compression ratio while allowing to reconstruct the compressed signals with better quality. At the time of writing this thesis, these are the first three devices that offer simultaneous multichannel optical stimulation, multichannel electrophysiological signals recording and on-the-fly spike detection. The resulting systems are more compact and lightweight than previous systems, making these devices essentials to conduct long term experiments on the brains of small freely moving animals. The three systems were validated within in vivo experiments using transgenic mice at the Centre de Recherche de l’Institut Universitaire en Santé Mentale de Québec (CRIUSMQ).
10

Theoretical investigation and numerical simulations of RF textiles antennas performance

Khalil, Mazen 23 April 2018 (has links)
Ce travail est consacré à la théorie et aux simulations numériques des nouveaux textiles qui peuvent communiqués sans-fil et composé des antennes fibre multimatériaux. La recherche est conduite par une tentative à changer le concept de "wearables" de grands dispositifs montés sur le corps à des dispositifs cachés confortables intégrés dans vos vêtements. Les textiles RF peuvent être prévus dans divers secteur des soins de santé, pour la surveillance des enfants et des personnes âgées, dans les domaines de télémédecine, de sécurité et de la recherche et sauvetage. Les antennes RF textiles, précédemment développées dans notre groupe, sont constituées de fibre multimatériaux en incorporant une couche conductrice d'argent dans un capillaire silice de 100 µm de diamètre à l'aide de la technique de déposition de phase liquide. La structure de ces antennes portables est flexible, se conforme au corps et non invasif. Dans ce travail, la performance de deux antennes de fibre, l'antenne dipôle et boucle, sont examinés à la bande de fréquence ISM par des simulations numériques à l'aide de logiciel ANSYS HFSS dans l'espace libre et sur le corps. À cette fin, le modèle de corps humain à plusieurs couches spécifiques a été développé en s'inspirant des valeurs proposées par le FCC "Federal Communications Commission" pour assigner les propriétés diélectriques de chaque tissu et pour satisfaire toutes les mesures de sécurité. Les résultats stimulés comprennent le déplacement de fréquence de résonance, les diagrammes de rayonnement affectés, le champ de rayonnement au-dessus du corps, l'efficacité et les mesures de SAR. En outre, la séparation de corps de l'antenne et les effets météorologiques sont également examinés. Les résultats présentés sont ensuite analysés en ce qui concerne les avantages et les inconvénients des deux designs, particulièrement dans le scénario sur le corps, tel qu'une attention spéciale est accordée à la robustesse et l'immunité contre la proximité du corps humain. / This work is devoted to the theory and numerical simulations of novel wireless-communicating textiles featuring multi-material RF fiber antennas embedded into textiles. The research is driven by an attempt to change the concept of wearables from large devices mounted on the body to a hidden and comfortable wearables integrated into your clothes. RF textiles antennas are expected to find multiple applications in various sectors of healthcare, child and elderly monitoring - telemedicine and home-nursing, security, search and rescue. RF textiles antennas, previously developed in our group, are made from multi-material fiber by incorporating a conductive layer of silver within a silica capillary of 100μm diameter using liquid phase deposition technique. The structure of these wearable antennas is flexible, conform to the body, and non-invasive. In this work the performance of two fiber antennas, namely dipole and loop, is investigated at ISM-band through numerical simulations using ANSYS HFSS both in free space and on-body scenario. For this purpose, the specific multi-layer human body model was developed using the “Federal Communication Commission” guidelines to assign the dielectric properties of each tissue and to satisfy all safety regulations. Simulated results include the shifting of resonance frequency, affected radiation patterns, radiation field above the body, efficiency and SAR measurements. In addition, antenna-body-separation distance and weather effects are also investigated. Presented results are then analyzed in terms of pros and cons of the two fiber antenna designs, especially in on-body scenario, as special attention is given to the robustness and immunity against the vicinity of human body.

Page generated in 0.5178 seconds