• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 316
  • 4
  • 3
  • Tagged with
  • 330
  • 330
  • 209
  • 206
  • 57
  • 55
  • 45
  • 44
  • 43
  • 38
  • 38
  • 34
  • 33
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Ecoeficiência de sistemas de tratamento de água à luz dos conceitos da ISO 14001 / Ecoefficiency of water treatment system from ISO 14001 concept

Cali Laguna Achon 08 October 2008 (has links)
No Brasil, existem milhares de sistemas de tratamento de água, que devem atender à critérios amplos de qualidade, que possibilite atender padrões e legislação pertinentes ao tipo de processo produtivo: antes, durante e após o processo. O Sistemas de Tratamento de Água (SiTA) engloba o manancial de abastecimento, seu entorno, a captação e adução de água bruta, a Estação de Tratamento de Água (ETA), a água tratada, o sistema de gestão, a Estação de Tratamento de Resíduos (ETR) e os recursos humanos. No desenvolvimento desse trabalho foram realizadas visitas técnicas em cinco SiTAs, que possuem tecnologia de ciclo completo, a fim de avaliar o funcionamento destes, segundo os princípios da ecoeficiência. Para tanto, foram levantados dados atuais e históricos (10 anos), que forneceram subsídios para elaboração e aplicação de 39 indicadores, agrupados em oito princípios da ecoeficiência. Neste trabalho foi proposto também um Sistema de Gestão Ambiental (SGA) para SiTAs, que foi baseado nos preceitos da norma ISO 14.001. Os resultados desta pesquisa apontam para a necessidade de uma nova visão, do intitulado Sistema de Tratamento de Água (SiTA), para que os projetos executivos futuros considerem impreterivelmente o manancial, o entorno e os resíduos gerados durante o processo de tratamento de água. Além disso, os cinco sistemas analisados não foram considerados ecoeficientes, seja em relação ao resultados dos indicadores aplicados, aspectos gerenciais, análise qualitativa e quantitativa, ausência de dados ou ineficiência na sua sistematização. Ademais, o planejamento, estabelecimento de metas e aplicação de indicadores em diferentes sistemas são fundamentais para o estabelecimento de um parâmetro balizador, que poderá ser seguido por outros sistemas de tratamento de água. Assim, é imperiosa a necessidade da implantação de um modelo de gestão, que forneça subsídios para geração e padronização dos dados nesse tipo de sistema. / In Brazil, there are thousands of water treatment systems, which must consider wide criteria of quality, and that will make possible to meet standards and legislation relevant to the type of production process: before, during and after the process. The Water Treatment Systems (WTSy) include the water supply source, its surroundings, catchment and adduction of raw water, the Water Treatment Plant (WTP), the treated water, the management system, the Waste Treatment Plant (WTP) and human resources. In the development of this work, technical visits were made in five WTSy, which have full cycle of technology, to evaluate the functioning of them, according to the principles of ecoefficiency. For both, current and historical data were raised (10 years), which provided subsidies for development and application of 39 indicators, grouped into eight principles of ecoefficiency. In this work it was also proposed an Environmental Management System (EMS) to the WTSy, which was based on the precepts of ISO 14.001. The results of this research, point to the need of a new vision, about the entitled Water Treatment System (WTSy), so that the executive future projects consider essential to the water supply source its surroundings, and the waste generated during the water treatment. In addition, the five systems reviewed were not considered ecoefficient, in relation to the results of the indicators applied, management aspects, quantitative and qualitative analysis, absence of data or inefficiency in its systematization. Moreover, the planning, setting targets and the application of indicators in various systems are fundamental to the establishment of a balizador parameter, which could be followed by other water treatment systems. It is therefore, imperative the need of implantation of a management model which provides subsidies for generation and standardization of data in this type of system.
202

Cinética de floculação de água bruta com baixa turbidez utilizando sais de alumínio e ferro como coagulante. / Flocculation kinetics of low-turbidity raw water using aluminum and iron salts as coagulants.

Marques, Rodrigo de Oliveira 15 December 2015 (has links)
Este trabalho teve como propósito investigar a cinética de floculação de água bruta com baixa turbidez, utilizando o sulfato de alumínio (Al2(SO4)3o18H2O) e o cloreto férrico (FeCl3o6H2O) como coagulantes. Os resultados experimentais foram obtidos em ensaios de \"jar test\". A água bruta utilizada nos ensaios foi preparada em laboratório, simulando um manancial superficial eutrofizado contendo células da cianobactéria Microcystis aeruginosa. Foram testadas 5 dosagens distintas de cada coagulante, 3 valores de G, 2 valores de TAS e 12 tempos de floculação. Utilizou-se a turbidez como medida principal de avaliação dos resultados experimentais. O valor de turbidez inicial (N0) foi corrigido, levando-se em consideração o acréscimo de turbidez em função das dosagens de coagulante. Determinou-se que as dosagens mais efetivas, em termos de remoção de turbidez, foram 20 mg.L-1 para o sulfato de alumínio e 40 mg.L-1 para o cloreto férrico (ambas expressas como massa de coagulante). Para ambos os coagulantes, constatou-se que G = 20 s-1 e TAS = 27 m3.m-2.dia-1 resultaram nas melhores eficiências de remoção de turbidez. Verificou-se também a variação do potencial zeta em função das dosagens de coagulante. Observou-se que o aumento da dosagem de coagulante leva à redução do potencial zeta, aproximando-o do ponto isoelétrico. Porém, o ponto isoelétrico não necessariamente coincide com a melhor eficiência em termos de remoção de turbidez. Com base nos resultados experimentais, foi proposta uma modificação ao modelo clássico da cinética de floculação de suspensões coloidais. Nesta, foi incluso um segundo termo referente à ruptura de flocos (quebra irreversível). O ajuste do modelo proposto foi obtido através de procedimentos de iteração numérica computacional com a função \"Solver\" do programa Microsoft Excel®. Foram calculados os valores das constantes KA, KB e KC do modelo proposto. Amostras do lodo gerado nos ensaios de cinética de floculação foram caracterizadas visualmente através de microscopia eletrônica de varredura (MEV). / The purpose of this work was to investigate flocculation kinetics of low-turbidity raw water, using aluminum sulfate (Al2(SO4)3o18H2O) and ferric chloride (FeCl3o6H2O) as coagulants. Experimental results were obtained in jar tests. Raw water used in the jar tests was prepared in laboratory, simulating a eutrophic natural water source containing cells of the cyanobacteria Microcystis aeruginosa. 5 different coagulant doses were tested for each coagulant, 3 G values, 2 SLR values and 12 flocculation times. Turbidity was selected as the major parameter for experimental results analysis. Initial turbidity values (N0) were corrected taking into account turbidity increase due to coagulant dosing. In terms of turbidity removal, it was determined that the most effective dosage for aluminum sulfate was 20 mg.L-1, and for ferric chloride, 40 mg.L-1 (both expressed as coagulant mass). For both coagulants, it was found that G = 20 s-1 and SLR = 27 m3.m-2.day-1 resulted in the best turbidity removal efficiencies. Zeta potential variation, due to coagulant dosing, was also verified. It was noted that increasing coagulant dosing led to zeta potential reduction, bringing it closer to the isoelectric point. However, the isoelectric point does not necessary coincides with the best turbidity removal efficiency. Based on the experimental results, it was proposed a modification to the classic colloidal suspension flocculation kinetics model. In this modification, a second term regarding floc rupture (irreversible breakage) was included. Through computer numeric iteration using Microsoft Excel®\'s \"Solver\" function, the proposed model adjustment was obtained. Kinetics constants KA, KB e KC values, from the proposed model, were calculated. Sludge samples, generated during flocculation kinetics tests, were visually characterized through scanning electronic microscopy (SEM).
203

Emprego de filtro de fibra flexível constituído de sisal e de polipropileno na clarificação de água para abastecimento / Employment of flexible fiber filter made of sisal and polypropylene in the clarification of water to supply

Morita, Alice Kimie Martins 12 June 2013 (has links)
Os filtros de fibra flexível são módulos de filtração recentemente desenvolvidos cujo leito é constituído de fibras de poliamida, o que permite a obtenção de altas eficiências de remoção de sólidos associadas a altas taxas de filtração. Este estudo objetivou avaliar o desempenho deste tipo de filtro utilizando-se como meio filtrante fibras flexíveis de sisal e de polipropileno. Com isso se buscou aprofundar o entendimento da técnica de filtração em leito de fibras flexíveis, além de propor e avaliar leitos com fibras diferentes daquelas citadas na literatura (constituídas de poliamida), neste caso fibras naturais (sisal) e fibras de polipropileno. A superfície das fibras em estudo foi analisada por meio de microscopia óptica e eletrônica de varredura e através de ensaios de solubilidade em ácido clorídrico e hidróxido de sódio, com a finalidade de investigar as características superficiais dos materiais filtrantes e sua solubilidade. Foram construídos 6 filtros com diâmetro interno de 28 mm e porosidade de leito de 93%, sendo 3 constituídos de fibras de sisal com comprimentos de leito de 25,60 e 100 cm, e 3 constituídos de fibras de polipropileno, também nos comprimentos de 25,60 e 100 cm. Em um segundo momento foi avaliado o desempenho de filtros constituídos de sisal nos mesmos comprimentos citados, no entanto com porosidade de leito de 85%. Foi utilizada para alimentação dos filtros água sintética com 8,19 ± 0,85 uT e 14,47 ± 5,25 uC e foi realizada coagulação in-line por meio da adição de 22,5 mg/L de sulfato de alumínio. Foram avaliadas taxas de filtração desde 5 m/h até 80 m/h no caso dos filtros do sisal com diferentes comprimentos e porosidades, e desde 20 m/h até 80 m/h no caso dos filtros de polipropileno. O limite de turbidez estabelecido para o filtrado foi de 1 uT. Puderam operar dentro do limite de turbidez estabelecido os filtros de polipropileno de 25,60 e 100 cm com taxa de 20 m/h e de 60 e 100 cm com taxas de até 80 m/h, e o filtro de sisal de 100 cm e 85% de porosidade com taxas de 20 e 40 m/h. Os maiores volumes de filtrado foram obtidos para filtro de polipropileno de 100 cm operando com taxa de 20 m/h, no entanto estes foram associados a maior perda de carga. Por outro lado, o filtro de sisal de 100 cm produziu menor quantidade de filtrado, porém com perda de carga associada consideravelmente baixa. Os melhores índices de filtrabilidade foram obtidos para o filtro de sisal de 100 cm de comprimento e 85% de porosidade de leito, o que indica seu potencial de aplicação, especialmente em ocasiões em que a carga hidráulica disponível seja restrita e a turbidez exigida do filtrado não seja demasiadamente baixa (inferior a 0,5 uT). Sugere-se a utilização de filtros constituídos de fibras de sisal como unidades de pré-filtração ou a construção de leitos com menor porosidade e maior comprimento de leito do que os utilizados neste estudo, caso se objetive aplicação em tratamento de água para abastecimento. Este estudo mostrou que é possível utilizar fibras de sisal e de polipropileno em filtros de fibras flexível, e a escolha dos diferentes tipos de fibras, comprimentos e porosidades de leito dependeria da disponibilidade no local, da qualidade do efluente exigida e da carga hidráulica disponível. / The flexible fiber filter is a filtration module recently developed whose filter media is made of polyamide fibers, what permits to obtain high solids removal efficiency associated to high application rates. The objective of this study was to evaluate the performance of this kind of filter using as filter media flexible fibers of sisal and polypropylene. With this it was intended to deepen the understanding of the filtration technique using flexible fibers as media and to propose and evaluate filter medias made of fibers different from the ones found in the literature: natural fibers (sisal) and polypropylene fibers. The fibers in study were analysed by means of optic and scanning electronic microscopy and through solubility essays in chloridric acid and sodium hydroxide, with the intention to characterize the filtering materials and find if there are restrictions of their use. Six filters with 28 mm of intern diameter and 93% of porosity were constructed, three being made of sisal fibers with 25, 60 and 100 cm of length, and three being made of polypropylene fibers, with 25,60 and 100 cm of length, too. In a second moment three other sisal fibers were constructed and evaluated, with the same lengths studied before, but with porosity of the filter medium of 85%. The filtration system was fed with synthetic water with 8,19 ± 0,85 uT and 14,47 ± 5,25 uC, and in-line coagulation was applied by the addition of 22,5 mg/L of aluminium sulfate. In the case of the sisal filters, made of different lengths and porosities, rates from 5 m/h to 80 m/h were evaluated; in the case of polypropylene filters, rates from 20m/h and 80m/h were evaluated. It was established as the turbidity limit the value of 1 uT. The filters that worked within the established turbidity limit were the polypropylene filters of 25,60 and 100 cm for the rate of 20 m/h and of 60 and 100 cm for rates until 80m/h, and the sisal filter of 100 cm and 85% of porosity for rates of 20 and 40 m/h. The biggest filtrate volumes were obtained for polypropylene filter of 100 cm working with the rate of 20 m/h; however this one was associated to the biggest values of pressure drop. On the other hand, the filter made of sisal with 100 cm produced a smaller quantity of filtrate, but associated to a considerably low value of pressure drop. The best filterability indexes were obtained for the filter made of sisal with 100 cm of length and 85% of porosity, what indicates its application potential, mainly to situations when there is not enough hydraulic charge and when the requested turbidity of the filtrate is not too low (less than 0,5 uT). It is suggested that the filters made of sisal are used as pre-filtration units or that they are built with smaller values of porosity and/or with a longer filter length than the ones used in this study, in the case that water treatment application is aimed. This study showed that it is possible to use sisal and polypropylene fibers in flexible fiber filters, and that the choice of different types of fibers, lengths and porosities depends on de availability of materials in the local, on the required quality of the filtrate and on the available hydraulic charge.
204

Remoção de fluoretos em amostras de água utilizando lodo de ETA como adsorvente

Araujo, Diego Erieudes 06 June 2016 (has links)
Submitted by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T14:49:46Z No. of bitstreams: 1 ARAUJO_Diego_2016.pdf: 24101509 bytes, checksum: 492307eea8861ce7d88418638e6b6051 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T14:49:53Z (GMT) No. of bitstreams: 1 ARAUJO_Diego_2016.pdf: 24101509 bytes, checksum: 492307eea8861ce7d88418638e6b6051 (MD5) / Approved for entry into archive by Milena Rubi (milenarubi@ufscar.br) on 2017-08-16T14:50:00Z (GMT) No. of bitstreams: 1 ARAUJO_Diego_2016.pdf: 24101509 bytes, checksum: 492307eea8861ce7d88418638e6b6051 (MD5) / Made available in DSpace on 2017-08-16T14:50:07Z (GMT). No. of bitstreams: 1 ARAUJO_Diego_2016.pdf: 24101509 bytes, checksum: 492307eea8861ce7d88418638e6b6051 (MD5) Previous issue date: 2016-06-06 / Não recebi financiamento / Water sludge is a solid waste produced during the water treatment. The volume of sludge produced in a water treatment plant can reach tons of material per month, depending of the quantity of water treated in the plant. Water sludge characteristics can vary depending of the water source and chemical products used in the water treatment. This material is rich in iron oxides, alum oxides, minerals and humic substances. Nowadays all this waste doesn’t have an application, being usually discharged in landfills, after a drying process, or into rivers. On the other hand, fluoride: an ion commonly founded in water samples from drilled wells. According to the current potability standard, administrative order number 2914/11 from Brazilian Govern Health Department, fluoride is necessary for water quality, being indispensable to avoid caries, primarily in children. However, in high concentrations – above 1,5 mg F?.L-1 –, fluoride causes health problems to the consumers, as dental fluorosis and skeletal fluorosis. Moreover, in a high concentration level, fluoride interferes or even hinders the application of this water to public supply, because most of the disposable technologies for fluoride removal have a high financial cost. That said, this work was planned to look for and combine a solution for both problems: utilization for water sludge and an alternative to fluoride removal with low cost. For this purpose, fluoride removal tests were done using fluoride standard samples in a jar-test equipment. These experiments were lead in different pH, to verify the pH influence in the fluoride removal process on the water sludge surface. After the experiments with the fluoride standard samples, a groundwater sample from the city of Capela do Alto, São Paulo state, was used to verify the efficiency of the material in a raw water sample with high fluoride, 2,8 ± 0,02 mg F?.L-1. The maximum adsorption result reached in fluoride standard sample was 0,36 ± 0,02 mg F?/g sludge, in pH 4. The minimum adsorption capacity was reached in pH 6, 0,30 ± 0,02 mg F?/g sludge. In the experiment with groundwater (pH 8,3), the maximum adsorption was 0,34 ± 0,02 mg F?/g sludge, showing the low pH influence in the fluoride adsorption onto water sludge. / O lodo de ETA é um resíduo sólido gerado durante o processo de tratamento da água, cujo volume gerado em uma estação de tratamento pode chegar a toneladas por mês, dependendo da quantidade de água tratada. Apesar de suas características variarem de acordo com a fonte de água utilizada e produtos empregados no tratamento da água, este material é rico em óxidos de ferro, de alumínio, minerais e materiais húmicos. Atualmente todo esse resíduo não possui um uso, sendo frequentemente descartado em aterros sanitários após processo de secagem ou lançado in natura nos corpos d’água. Outra questão comum da área de saneamento, o fluoreto: um íon comumente encontrado em amostras de águas subterrâneas. De acordo com o padrão de potabilidade vigente, Portaria 2914/11 do Ministério da Saúde, o fluoreto é necessário para a qualidade da água, sendo indispensável no combate às cáries, principalmente em crianças. Entretanto, quando em concentrações acima da máxima permitida, 1,5 mg F?.L-1, pode acarretar em problemas de saúde aos usuários do manancial, como fluorose dentária e óssea. Por este motivo, a concentração deste íon acima dos limites estabelecidos, pode inviabilizar o uso desta água para abastecimento público, visto que muitas das tecnologias utilizadas para sua remoção apresentam um alto custo. Sendo assim, este trabalho foi elaborado como forma de unir e buscar uma solução para ambos os problemas: uso para o lodo de ETA e alternativa de remoção de fluoreto à baixo custo. Para tanto, realizou-se ensaios de remoção em jar-test (teste de jarros) com padrões de fluoreto. Esses testes foram conduzidos em diferentes valores de pH, a fim de que se verificasse o grau de influência deste parâmetro no processo de adsorção do fluoreto pelo lodo de ETA. Após os testes em soluções padronizadas, utilizou-se uma amostra de água com concentração de fluoreto acima da permitida, 2,80 ± 0,02 mg F?.L-1, de um poço da cidade de Capela do Alto, estado de São Paulo, para se verificar o rendimento adsortivo do lodo em uma amostra de água in natura. Utilizando-se a solução padrão, o valor máximo de adsorção obtido foi de 0,36 ± 0,02 mg F?/g de lodo em pH 4. O menor rendimento, experimento em pH 6, foi de 0,30 ± 0,02 mg F?/g de lodo. No ensaio com a amostra de água de poço (pH 8,3), alcançou-se uma adsorção de 0,34 ± 0,02 mg F?/g de lodo. Os resultados sinalizam uma alternativa aos adsorventes utilizados atualmente, que alia eficiência de processo e reuso de um rejeito sólido com pouca, ou nenhuma, utilização.
205

Tecnologias limpas aplicadas ao tratamento de águas residuárias domésticas para reuso no semiárido / Clean Technologies applied to domestic wastewater treatment for reuse in the semi-arid

Lopes, Humbelina Silva Siqueira 24 February 2012 (has links)
Made available in DSpace on 2016-08-31T13:15:07Z (GMT). No. of bitstreams: 1 HumbelinaSSL_DISSERT.pdf: 3127454 bytes, checksum: 33b00e3001eeb7b35be68ce903acff56 (MD5) Previous issue date: 2012-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The scarceness of water and the lack of sanitation services in rural environment is a reality of northeastern semi-arid, being indispensable the development of low cost technologies, with easy operation and high efficiency, in addition to being environmentally accepted by society. Considering that, this work intended to analyze the performance of mini-stations of domestic wastewater treatment for reuse in northeastern semi-arid regions. The experiments have been done at UFERSA s experimental areas in Mossoró RN, experiments I with grey water, experiment II with domestic sewage. Some procedures were made to analyze the mini-stations, they were the flow measurement and the characteristic determination: hydrogen-ion potential (pH), electrical conductivity (EC), turbidity (TB), total coliforms (TC), thermotolerant coliforms (ThC), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total solids (TS), suspended solids (SS), total phosphorus (P-total), total nitrogen (N-total), oil and grease (OG) and nitrate (NO3-). The experiments were set in the Completely Randomized Design with four repetitions and four treatments (treatment levels). The analysis of variance was done to 1 and 5 % of probability, the averages were compared using Turkey s test at 5 % of probability. The results evidence that the applied treatment at experiments I caused significant removals of the characteristics TB, TC, ThC, COD, BOD, TS, SS, P-total and OG; and by the average level of 29.22 MJ m-2 d-1 the obtained average removal was 98.82 % at ThC population. At experiments II significant removals occurred of TB, TC, ThC, COD, BOD, SS, P-total, NO3- and OG; and with average solar radiation of 27.81 MJ m-2 d-1, it occurred an average removal in ThC population of 99.98 %. The mini-stations of domestic wastewater treatment enable the effluent the microbiological quality that follows the national guidelines to fertigation of crops when not eaten raw / A escassez de água e a falta de esgotamento sanitário em ambientes rurais é uma realidade do semiárido nordestino, tornando imprescindível o desenvolvimento de tecnologias de baixo custo, fácil operação e alta eficiência, além de serem ambientalmente aceitas pela sociedade. Diante do exposto, o trabalho objetivou analisar o desempenho de miniestações de tratamento de águas residuárias domésticas para reuso em regiões semiáridas do nordeste. Os experimentos foram realizados em áreas experimentais da UFERSA em Mossoró-RN, sendo o experimento I com água cinza e o experimento II com esgoto doméstico. Para avaliação do desempenho das miniestações procedeu-se com a medição de vazão e determinação das características: potencial hidrogeniônico (pH), condutividade elétrica (CE), turbidez (TB), coliformes totais (CT), coliformes termotolerantes (CTe), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), sólidos totais (ST), sólidos suspensos (SS), fósforo total (Ptotal), nitrogênio total (Ntotal), oléos e graxas (OG) e nitrato (NO3-). Os experimentos foram montados no Delineamento Inteiramente Casualizado com quatro repetições e quatro tratamentos (níveis de tratamento). Foi realizada a análise de variância a 1 e 5 % de probabilidade, as médias foram comparadas utilizando-se o teste de Turkey à 5 % de probabilidade. Os resultados evidenciaram que o tratamento aplicado no experimento I acarretou remoções significativas das características TB, CT, CTe, DQO, DBO, ST, SS, Ptotal e OG; e mediante nível médio de 29,22 MJ m-2 d-1 foi obtido remoção média de 98,82 % na população de CTe. No experimento II houveram remoções significativas de TB, CT, CTe, DQO, DBO, SS, Ptotal, NO3- e OG; e com radiação solar média de 27,81 MJ m-2 d-1, ocorreu remoção média na população de CTe de 99,98 %. As miniestações de tratamento de águas residuárias domésticas possibilitaram ao efluente qualidade microbiológica que atende as diretrizes nacionais para fertirrigação de cultivos agrícolas não consumidos crus
206

Diagnóstico dos resíduos gerados em estações de tratamento de água nas bacias dos rios Piracicaba, Capivari e Jundiaí - SP

Vilella, Alexandre Luis Almeida 20 July 2011 (has links)
Made available in DSpace on 2016-06-02T20:00:38Z (GMT). No. of bitstreams: 1 3860.pdf: 7904482 bytes, checksum: fcce0b9ff411b2bc48b7a967806bdb8c (MD5) Previous issue date: 2011-07-20 / The basins of Piracicaba, Capivari and Jundiaí has a territory of 15,304 square kilometers, about 5.2 million inhabitants, 7% of gross national product. However, the scarcity of water resources threatens all this prosperity. The uses of water have led to conflicts because of its multiple and diverse purposes, which require different quantities and qualities. It is against this background that becomes fundamental to understand the current situation of water supply and waste management from the treatment process. The mobilization of society, awareness of public officials and increase the availability of financial resources for the sanitation sector have provided the municipalities to increase their rates of water treatment, through the construction of new structures and technological innovations, however, has aroused another focus attention to the urgent need for the systemic management of waste from water treatment plants, especially the generation, treatment and disposal of sludge and its actual and potential environmental impacts. This research has made diagnosis of generation under the quantitative aspect of the sludge generated in the 89 water treatment plants operating in 58 cities, and identify some experiences about the management. Through various methodological tools, such as the use of questionnaires for data collection to obtain primary data, the paper presents and discusses information about the current generation of waste, existing experiences regarding the disposal and treatment, and the challenges issue requires to be addressed. The results pointed that 9013.20 tons of monthly dry solids are generated, with prominence the one that 70% of plants in operation don't possess any of measurement of the muds system. The realities, front to the service of the effective legislations, training lack and the managers systemic administration and operators on the theme as well as the need of the integration of the sectorial politics with the operation of the systems of water supply that are the great challenges to be overcome. / As bacias hidrográficas dos Rios Piracicaba, Capivari e Jundiaí possuem um território de 15.304 Km², cerca de 5,2 milhões de habitantes, 7% do Produto Interno Bruto Nacional. No entanto, a escassez dos recursos hídricos ameaça toda essa prosperidade. Os usos da água têm gerado conflitos em razão de sua multiplicidade e finalidades diversas, as quais demandam quantidades e qualidades diferentes. É diante desse panorama que se torna fundamental o conhecimento do cenário atual do abastecimento de água e a gestão dos resíduos oriundos do processo de tratamento. A mobilização da sociedade, a conscientização dos gestores públicos e o aumento da disponibilidade de recursos financeiros para o setor de saneamento têm proporcionado que os municípios aumentem os seus índices de tratamento de água, através da construção de novas estruturas e inovações tecnológicas, entretanto, tem despertado a atenção para outro foco, a premente necessidade da gestão sistêmica dos resíduos oriundos das estações de tratamento de água, com destaque a geração, tratamento e disposição dos lodos e seus potenciais e efetivos impactos ambientais. Este trabalho procurou diagnosticar a geração sob o aspecto quantitativo dos lodos gerados em 89 ETAs em operação nos 58 municípios paulistas integrantes da UGRHI n.° 5, além de identificar algumas experiências quanto ao gerenciamento. Através de diversos instrumentos metodológicos, como a utilização de questionários de coleta de dados para obtenção de dados primários, a adoção de métodos teóricos, visitas técnicas, o trabalho apresenta e discute as informações acerca da geração atual desses resíduos, as experiências existentes quanto à destinação final e tratamento, além dos desafios que a temática exige a serem enfrentados. Os resultados apontaram que são gerados 9013,20 toneladas de sólidos secos mensais, com destaque a que 70% das ETAs em operação não possuem sistema algum de medição dos lodos. As realidades, frente ao atendimento das legislações vigentes, carência de capacitação e gestão sistêmica dos gestores e operadores sobre a temática bem como a necessidade da integração das políticas setoriais com a operação dos sistemas de abastecimento de água que se demonstraram como grandes os desafios a serem superados.
207

Técnicas analíticas para autópsia de membranas de osmose reversa. / Analytical techniques for the autopsy of reverse osmosis membranes.

Thiago Ranzani da Costa 17 November 2011 (has links)
Sistemas de membranas filtrantes, principalmente os de osmose reversa, estão sendo cada vez mais utilizados em diversos seguimentos de empresas (farmacêutica, tratamento de água, alimentícia e química), devido à diminuição do preço dos elementos filtrantes e da alta qualidade do produto obtido. Apesar do preço dos elementos de osmose reversa terem caído nos últimos tempos, a substituição destes continua sendo o fator mais dispendioso de um sistema de osmose reversa. A autópsia de membranas é uma técnica utilizada para investigar a causa que levou à colmatação de um elemento, contribuindo no melhoramento do pré-tratamento da água de alimentação e consequentemente aumentando a vida útil dos elementos. O presente trabalho teve como objetivo incrementar a técnica de autópsia de membranas de osmose reversa através da análise da volatilização dos principais compostos inorgânicos presentes nestas membranas, modificação na metodologia de quantificação de açúcares e proteínas, comparação de diferentes técnicas de remoção do material depositado sobre as membranas e análise da distribuição de biofilmes sobre elementos colmatados de osmose reversa. A análise dos resultados mostrou que dentre os inorgânicos, ocorreu volatilização completa do cloreto de amônio e pequena variação no composto cloreto férrico; a quantificação de proteínas e açúcares, através da fortificação das amostras, apresentou valores diferentes quando comparados com os valores obtidos diretamente da curva padrão, devido à diferença de inclinação entre as retas de fortificação e padrão; os resultados também mostraram que a trituração foi mais eficiente na remoção do material aderido quando comparado com a raspagem e a sonicação e a distribuição de biofilmes se mostrou uniforme nos dois elementos analisados. / Filter membrane systems, especially reverse osmosis, are being increasingly used in various business segments (pharmaceutical, water treatment, food and chemical) due to decrease in the price of the filter elements and high quality product. Although the price of reverse osmosis elements have fallen in recent times, the replacement of the part remains more expensive a reverse osmosis system. The autopsy of membranes is a technique used to investigate the cause that led to clogging of one factor contributing to the improvement of pre-treatment of water feeding and consequently increasing the life of the elements. This study aimed to improve the technique of autopsy reverse osmosis membranes by examining the volatilization of major inorganic compounds present in these membranes, modification the methodology for quantification of sugars and proteins, comparison of different techniques for removal of material deposited on the membranes and distribution analysis of biofilms on elements obscured reverse osmosis. The results showed that among the Inorganic volatilization was full of ammonium chloride and small variation in the compound ferric chloride, the quantification of proteins and sugars, by fortifying the samples showed different values when compared with values obtained directly the standard curve due to the difference in slope between the lines of and fortification standard, the results also showed that the blending was more efficient in removing adhered material when compared with the scraping and sonication and distribution of biofilms showed uniform the two elements analyzed.
208

CARBONATAÇÃO ACELERADA EM CONCRETOS COM ADIÇÃO DE CINZAS DE LODO DE ESTAÇÃO DE TRATAMENTO DE ÁGUA / ACCELERATED CARBONATION IN CONCRETE WITH ADDITION OF WATER TREATMENT PLANT SLUDGE ASHES

Adorna, Diego da Luz 14 July 2016 (has links)
Carbonation is a natural phenomenon for concrete structures and occurs due to the reaction between CO2, which is concentrated in the environment, and Ca(OH)2, which is present in the cementitious matrix. Carbonation reaction reduces the pH of the concrete and causes the destruction of the passivation layer, which surrounds the steel armor, leaving it vulnerable to the process of corrosion. In this study, was investigated the performance against the carbonation of concrete with the addition of water treatment plant sludge ashes, in concentrations of 5%, 10%, 15%, 20%, 25% and 30% replacing Portland cement, as well as a reference blend without mineral admixtures. All mixtures were molded with three w/b ratios (0.35; 0.50 and 0.65) and with two periods of wet cure (three and seven days). Concrete specimens underwent preconditioning according to RILEM TC 116-PCD, targeting the moisture balance (75% ± 2%) in an aerial environment with constant temperature (23° C ± 2° C) and uniform moisture distribution. Afterwards, specimens were forwarded to a carbonation chamber, with humidity (75 ± 2%), temperature (23°C ± 2° C) and CO2 concentration (3%) duly regulated. Specimens were tested after 4, 8, 12 and 16 weeks of CO2 exposure through phenolphthalein spraying, the depths of carbonation is obtained and, therefore, the carbonation coefficients. Results revealed that the incorporation of water treatment plant sludge ashes into concrete leads to increases in its carbonation, in all mixtures investigated. Comparisons with the results for Porosimetry by Mercury Intrusion and Thermogravimetry enable attribute this effect to the microstructural change and decrease of alkalinity of the mixture with addition of sludge ash. Through an analysis of equal resistance, it was found that concrete with addition of sludge ash water treatment are feasible, from the point of view of carbonation's lifespan, only to higher strength levels. / A carbonatação é um fenômeno natural às estruturas de concreto, ocorrendo pela reação entre o CO2, concentrado no ambiente, e o Ca(OH)2, presente na matriz cimentícea. A reação de carbonatação provoca a redução do pH do concreto, causando a destruição da camada passivadora, que envolve a armadura de aço, deixando esta vulnerável ao processo de corrosão. Nesta pesquisa, foi investigado o desempenho, frente à carbonatação, de concretos com adição de cinzas de lodo de estação de tratamento de água, nos teores de 5%, 10%, 15%, 20%, 25% e 30% em substituição ao cimento Portland, bem como uma mistura de referência, sem adições minerais. Todas as misturas foram moldadas com três relações a/agl (0,35; 0,50 e 0,65) e com dois períodos de cura úmida (três e sete dias). Os corpos-de-prova de concreto foram submetidos à um pré-condicionamento, conforme procedimentos sugeridos pela norma RILEM TC 116-PCD, visando o equilíbrio de umidade (75% ± 2%) em um ambiente aéreo com temperatura constante (23°C ± 2°C) e distribuição uniforme de umidade. Posteriormente os corpos-de-prova foram encaminhados para uma câmara de carbonatação, com umidade (75% ± 2%), temperatura (23°C ± 2°C) e concentração de CO2 (3%) devidamente reguladas. Os corpos-de-prova foram ensaiados após 4, 8, 12 e 16 semanas de exposição ao CO2, por meio de aspersão de fenolftaleína, sendo obtidas as profundidades de carbonatação e, com isso, os coeficientes de carbonatação. Os resultados demonstraram que a incorporação de cinzas de lodo de estação de tratamento de água ao concreto acarreta no aumento da carbonatação nos mesmos, para todas as misturas investigadas. Comparações com resultados de Porosimetria por Intrusão de Mercúrio e Termogravimetria permitiram atribuir este efeito às alterações microestruturais e a diminuição da reserva alcalina das misturas com adição de cinzas de lodo. Através de uma análise em igualdade de resistência, constatou-se que os concretos com adição de cinzas de lodo de estação de tratamento de água são viáveis, do ponto de vista da vida útil frente à carbonatação, apenas para níveis de resistência mecânica mais altos.
209

Gestão de resíduo e tecnologia ambiental na fabricação de tijolos solo-cimento

Samson, Bárbara pereira 28 April 2016 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-07-14T12:50:22Z No. of bitstreams: 1 arquivototal.pdf: 8841136 bytes, checksum: aaa642f094b0481f15236b39854feb0a (MD5) / Made available in DSpace on 2017-07-14T12:50:22Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 8841136 bytes, checksum: aaa642f094b0481f15236b39854feb0a (MD5) Previous issue date: 2016-04-28 / Currently we have been sought new constructive solutions involving environmental sustainability through the reduction / elimination of waste of raw materials and final products. The reduction of waste has been granted by the rational use of materials and various forms of reuse, for both are studied and developed technologies capable of absorbing this waste. Under the basic sanitation is highlighted waste generated in water treatment plants during the process of purifying plants of water intended for human consumption. This residue is commonly called sludge. For environmental issues, frequent studies point to the incorporation of this waste in construction materials such as conventional bricks and soil cement. Laboratory analyzes were: Fluorescence Xray (XRF) , Chemical Oxygen Demand (COD) , Biochemical Oxygen Demand (BOD), Particle size , Plasticity Index and resistance to simple compression. This the following study aims to evaluate the incorporation of the waste generated in the Water Treatment Plant - Gramame in soil-cement bricks type. The concreteness of research leads to consideration of the incorporation of the waste generated in the Water Treatment Plant - Gramame in low percentages do not affect the strength of soil-cement bricks. This result associated with a considerable concentration of Organic matter. / Atualmente têm-se buscado novas soluções construtivas que envolvam a sustentabilidade ambiental através da diminuição/eliminação de desperdício das matérias-primas e produtos finais. A redução dos desperdícios vem sendo conferida pelo uso racional dos materiais e as diversas formas de reutilização, para tanto são estudadas e desenvolvidas tecnologias capazes de absorver estes resíduos. No âmbito do saneamento básico é destacado o resíduo gerado nas Estações de Tratamento de Água durante o processo de potabilização das águas destinadas para o consumo humano. Comumente este resíduo é chamado de lodo. Para as questões ambientais, estudos frequentes apontam para a incorporação deste resíduo em materiais de construção civil tais como tijolos convencionais e solo-cimento. Desta forma, o seguinte trabalho visa avaliar a incorporação do resíduo gerado na Estação de Tratamento de Água – Gramame em tijolos do tipo solo-cimento. Para que os objetivos pudessem ser alcançados foram determinadas as análises laboratoriais de: Fluorescência de Raio-X (FRX), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Granulometria, Índice de Plasticidade e Resistência a Compressão Simples. A concretude da pesquisa leva a conclusão de que a incorporação do resíduo gerado na Estação de Tratamento de Água – Gramame em baixas porcentagens não prejudica a resistência dos tijolos solo-cimento. Sendo este resultado associado a uma considerável concentração de Matéria Orgânica.
210

Propriedades físico-químicas da água com preparados homeopáticos / Physical and chemical properties of water with homeopathic mixtures

Figueiredo, Christiane Chigane 12 February 2009 (has links)
Made available in DSpace on 2015-03-26T13:39:31Z (GMT). No. of bitstreams: 1 texto completo.pdf: 268685 bytes, checksum: 6c43e098e3bc77ffa2ecd071e3762516 (MD5) Previous issue date: 2009-02-12 / Considering the agricultural handling, this paper had as main aim to evaluate the physical-chemical properties of the mixture of water with homeopathic substances. The experiments were conducted at the Homeopathy Laboratory DFT/UFV. The homeopathic substances were prepared at Homeopathy Laboratory DFT/UFV, driven in distilled water and applied through the double-blind procedure. The mixture was distributed in polystyrene recipients, containing 80 ml of distilled water, in enough quantity to the application of two drops of each treatment and five repetitions. In the first experiment sixteen treatments were applied: fourteen homeopathic mixtures, mine water, driven water. The variables were measured three times, every three hours. In the second experiment, sixteen treatments were applied: fourteen homeopathic mixtures, mine water, driven water. The variables were measured six times, every twelve hours, in a period of 60 hours. In the third experiment, eleven treatments were applied: nine Rhus toxicodendron homeopathic mixture, with potency varying from 5 to 12 CH, mine water, and driven water. The variables were measured five times, every twelve hours, in a period of 48 hours. It was determined: pH, electric conductivity, dissolved oxygen, temperature and opacity of the treated water. So, the values were compared with the obtained results from the distilled water. It was concluded that the homeopathic mixtures alter the physical-chemical properties of the water. / Tendo em vista o manejo na agricultura este trabalho teve como objetivo avaliar propriedades físico-químicas da água com preparados homeopáticos. Os experimentos foram conduzidos no Laboratório de Homeopatia DFT/UFV. Os preparados homeopáticos foram elaborados no Laboratório de Homeopatia do DFT/UFV, dinamizados em água destilada e aplicados no procedimento duplo-cego . Distribuíram-se recipientes de poliestireno contendo 80 mL de água destilada em quantidade suficiente para a aplicação de 2 gotas de cada tratamento e cinco repetições. No primeiro experimento foram aplicados 16 tratamentos, sendo, 14 preparados homeopáticos, água de mina e água dinamizada. A medição das variáveis foi realizada 3 vezes no período de 3 em 3h. No segundo experimento foram aplicados 16 tratamentos, sendo, 14 preparados homeopáticos, água de mina e água dinamizada. A medição das variáveis foi realizada 6 vezes, de 12 em 12 horas, no período de 60h. No terceiro experimento foram aplicados 11 tratamentos, sendo, 9 preparados homeopáticos de Rhus toxicodendron com potência variando de 5 a 12 CH, água de mina e água dinamizada. A medição das variáveis foi realizada 5 vezes, de 12 em 12 horas, no período de 48h.Foram determinados: pH, condutividade elétrica, oxigênio dissolvido, temperatura e turbidez da água tratada. Os valores foram comparados com os resultados obtidos da testemunha, água destilada. Foi concluído que os preparados homeopáticos alteram as propriedades físico- químicas da água.

Page generated in 0.072 seconds