• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • Tagged with
  • 77
  • 77
  • 54
  • 37
  • 27
  • 26
  • 16
  • 15
  • 13
  • 12
  • 12
  • 12
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Proposição de modificações no processo UCT para o tratamento de esgoto sanitário visando à remoção de nitrogênio e fósforo. / Proposal of midifications in a modified UCT process to evaluate nitrogen and phosphorus removal efficiency.

Carvallho, André Vinícius Pion de 22 September 2016 (has links)
Atualmente, os processos de remoção biológica de nitrogênio e fósforo tem especial importância no âmbito brasileiro e mundial. Dentre os processos existentes, o Processo UCT Modificado é um dos principais processos capazes de realizar estas atividades. Este processo tem por característica básica possuir uma câmara anaeróbia para formação de ácidos orgânicos voláteis e duas câmaras anóxicas para a etapa de desnitrificação. Com o intuito de avaliar possíveis melhorias neste processo, operou-se uma planta piloto nos moldes de um UCT modificado porém com a câmara anaeróbia chicaneada e em uma segunda etapa introduziu-se microaeração nas câmaras anóxicas. Foi mantida idade do lodo em 10 dias e relação Alimento/microrganismos (A/M) entre 0,18 e 0,40 kg DBO5,20/kgSSV d. De acordo com os resultados obtidos não foi possível observar gerações de AOVs (ácido orgânico voláteis) na câmara anaeróbia. Com relação à atividade de microaeração das câmaras anóxicas foram observadas melhoras no processo de remoção biológica de nitrogênio se compara à operação sem microaeração. Em termos de remoção de matéria orgânica os resultados mostraram eficiências semelhantes a outros autores que desenvolveram sistemas semelhantes ao aqui estudado. / Now a days, nitrogen and phosphorus removal processes have been having a particular importance to Brazil and all the World. Considering the existing processes, Modified UCT is one of the main technologies capable of achieving this taks. This process has the characteristic of having one anaerobic tank aimed at producing volatile fatty acids (VFAs) and two anoxic tanks for denitrification. This paper tried to evaluate possible improvements in this process, operated a pilot plant with a compartmented anaerobic tank and later introduced microaeration to the anoxic tanks. Slugde age was maintained in 10 days and food/microorganisms rate (F/M) was maintained between 0,18 and 0,40 kg BOD/kg VSS d. According to the results, there was no clue of VFAs formation in the anaerobic tank. After the introduction of microaeration to the anoxic tanks it was shown an improvement in nitrogen removal. In terms of organic removal rates the plant had similar efficiency to other authors metioned in this paper.
32

Avaliação de reator UASB assistido quimicamente para remoção de fósforo / UASB reactor chemically assisted evaluation for phosphorus removal.

Queiroz, Ruy Scanho Marques de 17 May 2007 (has links)
Este trabalho visou avaliar a remoção de fósforo solúvel e total, carga orgânica, sulfetos e sólidos num esgoto doméstico fraco, ao qual se adicionou como coagulante o cloreto férrico, atravessando o manto de lodo de um tratamento anaeróbio UASB. A ETE Ribeirão Pires, aonde este estudo foi desenvolvido, conta com 4 reatores com capacidade para tratar 70 L/s, dos quais 2 foram utilizados, num deles (reator B) foram dosados 25 e 50 mg FeCl3/L e no outro (reator C) não houve dosagem, servindo como referência. Em cada uma das fases, foram realizadas 20 amostragens para DQO, fósforo total e solúvel, alcalinidade, pH e sólidos suspensos. Para DBO5,20ºC, sulfetos, sólidos totais e sedimentáveis foram obtidos 10 valores em cada dosagem. Os pontos de coleta foram: esgoto bruto e esgoto tratado dos reatores B e C. Foram coletadas amostras em 3 alturas do manto de lodo e realizadas as séries de sólidos em cada dosagem. Quanto à secagem desse lodo, os itens ciclo de desaguamento, espessura da camada e teor de sólidos foram comparados em descartes aos leitos de secagem da ETE. Da avaliação, pode-se concluir que a adição de cloreto férrico gera aumento considerável de remoção de carga orgânica (de 55% para 73% da DQO e de 63% para 82% da DBO5,20ºC, com 50 mg FeCl3/L). Quanto ao fósforo, as eficiências foram menores, sendo mais notadas nos ortofosfatos (de 28% para 36% de fósforo total e de 0% para 59% de solúvel com 50 mg FeCl3/L). Com relação ao lodo gerado, houve diminuição do ciclo de secagem e do volume da torta (do lodo com adição) em relação àquela gerada no reator sem adição de cloreto férrico. O manto de lodo se mostrou mais espesso e com menor concentração de sólidos no reator com aplicação de cloreto férrico, sugerindo uma tendência a maior perda de sólidos com o efluente clarificado. / The presented work intended to evaluate the removal of soluble and total phosphorus, organic matter (BOD5,20ºC and COD), sulfides and solids in a weak domestic wastewater, to which it was added ferric chloride as precipitant, crossing an UASB sludge blanket. The Ribeirão Pires wastewater treatment plant, where this study took place, is composed by 4 UASB reactors. In one of them (reactor B), 25 and 50 mg FeCl3/L were dosed, and in another (reactor C) there were no dosage, serving as a reference. In each of the stages, it had been carried through around 20 samplings for COD, total and soluble phosphorus, alkalinity, pH and suspended solids. For BOD5,20ºC, total sulfides, total solids and settleable solids it had been gotten 10 values in each dosage. The collection points had been: raw wastewater and treated wastewater from reactors B and C. Samples in 3 heights of the sludge blanket had been collected and carried through the solid series analysis in each dosage. About the sludge dewatering, items as dewatering period, layer thickness and total solids had been compared in some discharges to the drying beds. From this evaluation, it can be concluded that the ferric chloride addition generates an increase of organic matter removal (from 55% to 73% of the COD and from 63% to 82% of the BOD5,20ºC, with 50 mg FeCl3/L). For phosphorus, the removal efficiencies had been lower, more noticed in the soluble portion (from 28% to 36% of total and from 0% to 59% of soluble phosphorus at 50 mg FeCl3/L). Improvement in the dewatering capacity and in sludge cake volume were also noticed. The sludge blanket showed thicker and with a lower solid concentration in the reactor with ferric chloride application, suggesting a trend to solids loss in the clarified effluent.
33

Tratamento de águas residuárias utilizando emissários submarinos: avaliação do nível de tratamento para uma disposição oceânica ambientalmente segura. / Wastewater treatment using submarine outfalls: evaluation on the treatmente level for environmentally safe ocean disposal.

Subtil, Eduardo Lucas 23 May 2012 (has links)
Tendo em vista as questões ambientais relacionadas com a disposição oceânica de esgotos sanitários, muito tem sido debatido sobre qual nível de tratamento deve ser adotado ou quais constituintes presentes nos esgotos devem ser removidos antes do lançamento em regiões costeiras. Dentro deste contexto, este estudo teve como objetivo principal fornecer subsídios para uma tomada de decisão quanto à necessidade de remoção de nutrientes para lançamento de esgotos sanitários por meio de emissários submarinos, de maneira a garantir um nível de tratamento mínimo sem que haja um comprometimento do corpo receptor em termos de potencial de eutrofização. Para isso, foram utilizados dois sistemas de disposição oceânica de esgotos sanitários: Santos/São Vicente e Praia Grande 2. O impacto ambiental do lançamento de esgotos pelos emissários submarinos foi avaliado por um modelo numérico de eutrofização, sendo as características da pluma de esgoto no campo próximo determinada pelo software CORMIX e acoplado no modelo de campo distante. A necessidade de remoção de nitrogênio e fósforo foi estimada com base na metodologia do Plano Oceânico da Califórnia. Os resultados demonstraram que tanto para o caso do emissário submarino de Santos quanto para o de Praia Grande haveria necessidade de remover amônia e fosfato para atender a legislação CONAMA 357/2005 quando operados com vazões de 3,0 e 5,3 m³.s-¹. Além disso, quando os sistemas foram operados sem tratamento ocorreu um aumento significativo na concentração de clorofila-a, atingindo valores de até 16 µg chl-a/L 12 µg chl-a/L na baía de Santos e Praia Grande, respectivamente. Os resultados demonstraram também que a utilização de um tratamento secundário com oxidação parcial da amônia promoveria uma redução de apenas 30% na concentração de clorofila-a, enquanto que a utilização de um TPQA com remoção de fosfato promoveria uma resposta ambiental melhor, levando a uma redução de até 71% na concentração de clorofila-a, resultados semelhantes ao tratamento terciário com remoção de nitrogênio e fósforo, resultados semelhantes aos obtidos quando foi considerado o tratamento terciário com remoção de nitrogênio e fósforo. / Due to environmental issues related to wastewater ocean discharge, much has been debated about the level of treatment that should be adopted or which constituents must be removed from wastewater before its final disposal in coastal zones. Within this context, this study aimed to provide support for a decision making on the need of wastewater nutrient removal before its final disposal through submarine outfalls in order to ensure an adequate treatment level, minimizing the environmental impact on the receiving body in terms of eutrophication potential. For this purpose, two wastewater ocean disposal systems: Santos/San Viciente and Praia Grande 2, were evaluated. The environmental impact of wastewater discharge through submarine outfalls was evaluated by a 2D eutrophication numerical model. Wastewater mixing conditions in the near field plume was evaluated using the software CORMIX, and the results were coupled to a far-field model. Nitrogen and phosphorus removals were evaluated through the California Ocean Plan methodology. The results showed that the removal of ammonia and phosphate is required for both submarine outfalls, Santos and Praia Grande, to meet the Brazilian legislation(CONAMA357/2005) when they are operated with flow rates of 3.0 and5.3m³.s-¹. Furthermore, when the systems are operated without treatment, modeled chlorophyll-a concentrations increased up to 16 µg chl-a/L and 12 µg chl-a/L in Santos bay and Praia Grande, respectively. The results also demonstrate that the use of a secondary treatment with partial ammonia oxidation promote a reduction of only 30% in the chlorophyll-a, while the use of a CEPT with phosphate removal promote a better environmental response, resulting a chlorophyll-a concentration reduction of 71%, similar results were obtained when tertiary treatment was considered for nitrogen and phosphorus removals.
34

Avaliação temporal de indicadores de qualidade da água em microbacias do rio Piracicaba / Temporal evaluation of indicators of water quality in watersheds of the Piracicaba River

Vidas, Natássia Bonini 25 April 2014 (has links)
A unidade de estudo denominada bacia hidrográfica pode ser considerada um importante agente de integração entre processos naturais e antrópicos. Através do estudo do metabolismo dos corpos hídricos, pode-se conhecer fatores que implicam nas alterações funcionais destes processos. Seguindo nesse contexto, pode-se citar a bacia do rio Piracicaba, um autêntico modelo de bacia desenvolvida, com problemas ambientais típicos de áreas impactadas. Estudos desenvolvidos pelo Projeto PiraCena, entre os anos de 1994 e 2001, confirmaram que as emissões de esgotos domésticos e industriais e as mudanças no uso da terra, contribuíram para transformações drásticas no seu metabolismo. Entretanto, desde o encerramento deste projeto, recursos financeiros gerenciados pelos Comitês das Bacias Hidrográficas dos Rios Piracicaba, Capivari e Jundiaí foram aplicados, principalmente, em obras de saneamento como coleta e tratamento de esgotos domésticos. Assim, este estudo buscou avaliar durante doze meses a evolução de parâmetros físicos e químicos da água, visando conhecer como o processo de urbanização ainda afeta o metabolismo do rio e como os lançamentos de efluentes provenientes de estações de tratamento de esgoto interferem na composição química e no metabolismo aquático de ribeirões da bacia do rio Piracicaba, situados em regiões densamente ocupadas. Os resultados obtidos neste estudo foram ainda comparados com resultados publicados pelo Projeto PiraCena, com o objetivo de identificar possíveis melhorias na qualidade das águas desses ribeirões. Foi possível observar através dos resultados obtidos que apesar de todo esforço que tem sido feito visando a melhoria da qualidade da água dos corpos hídricos da bacia do rio Piracicaba, a deterioração ainda é continua. Além disso, foi possível reforçar os resultados encontrados pelo projeto PiraCena, uma vez que apesar de ter havido um aumento considerável no volume de esgoto doméstico tratado, esse tratamento não tem surtido efeito significativo sobre a qualidade da água de vários ribeirões da bacia. Portanto, é imperiosa uma avaliação detalhada sobre o funcionamento das estações de tratamento de esgoto para que as mesmas cumpram o seu papel que é prover a sociedade uma água de qualidade, assegurando ao mesmo tempo a integridade biótica da mesma. / The unit of study called watershed can be considered an important agent of integration between natural and anthropogenic processes. Studying the metabolism of water bodies, it is possible to know which factors are involved in the functional changes of these processes. In this context, it is inserted the Piracicaba river basin, an authentic model of developed basin with typical environmental issues of impacted areas. Studies conducted by PiraCena Project, between 1994 and 2001, confirmed that emissions from domestic and industrial sewage and changes in land use have contributed to drastic changes in its metabolism. However, since the end of the project, funds managed by the Watershed Committee of Piracicaba, Capivari and Jundiaí Watersheds were applied, mainly in sanitation, such as collection and treatment of domestic wastewater. Thus, this study aimed to evaluate the evolution of physical and chemical water parameters, during twelve months, trying to understand how the process of urbanization still affects the metabolism of the river and how the discharge of effluents from sewage treatment stations interfere in the chemical composition and the aquatic metabolism of streams that belong to the Piracicaba river basin, located in densely populated regions. The results obtained in this study were compared with previous results published by PiraCena Project, with the goal of identifying possible improvements at the water quality of these streams. It was observed from the results obtained that, despite every effort that has been made, aiming the improvement of the water quality at the water bodies of the Piracicaba river basin, the deterioration is still present. Moreover, it was possible to reinforce the results found by PiraCena project, since there was a considerable increase in the treated domestic sewage volume, but the effect of this treatment has not been significant to the quality of some streams of the basin. Therefore, the necessity of a detailed evaluation about the functioning of the sewage treatment stations is imperative, so they can continue providing the society with water of quality, while ensuring biotic integrity.
35

Estudo comparativo entre oito sistemas de lagoas de estabilização da região noroeste do Estado de São Paulo / Comparative study of eight systems of stabilization ponds in the northwestern region of São Paulo

Gomes, João Luiz Cais da Silva 10 April 2002 (has links)
Este trabalho comparou oito lagoas de estabilização da região Noroeste do Estado de São Paulo, que tratam esgotos predominantemente sanitários de Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Irapuã e Adolfo, cidades pequenas, com no máximo 5500 habitantes (1700 ligações), onde os quatro primeiros sistemas são compostos apenas por lagoas facultativas primárias e os quatro últimos por lagoas anaeróbias e lagoas facultativas secundárias. Vinte e cinco variáveis físicas, químicas e biológicas foram analisadas em amostras compostas coletadas entre 24/05/2000 e 03/10/2000. A análise da batimetria efetuada fornece indicações de prazos para a remoção do lodo do fundo das lagoas. As taxas de acúmulo de lodo médias obtidas para as lagoas anaeróbias e facultativas primárias foram de 0,07 e 0,14 m3/hab.ano, respectivamente. O pH do efluente das lagoas anaeróbias e das facultativas foi em média 6,6 e 7,4. Nas lagoas anaeróbias observou-se alta remoção de sólidos suspensos e de Demanda Bioquímica de Oxigênio (DBO) com eficiência geral média de 64% e 61% respectivamente. Os sistemas não atenderam plenamente à legislação no tocante a eficiência de remoção de DBO de 80%, porém o valor médio encontrado para os oito sistemas foi de 78%, bastante próximo do exigido. Sugere-se para a região, para eficiência de remoção de DBO de 80%, lagoas anaeróbias com tempo de detenção de 5 dias e para as lagoas facultativas primárias e secundárias tempos de detenção de 25 e 15 dias respectivamente, e taxas de aplicação superficial de 140 e 130 kg DBO/ha.dia, respectivamente. Não foi atingido o limite máximo de 1000 coliformes fecais por 100 ml, obtendo-se média geral de remoção de 97,40% inferindo-se que há necessidade de um processo de tratamento complementar para a remoção de microrganismos. Não observou-se correlação entre eficiência do sistema e relação comprimento/largura das lagoas. Constatou-se maus odores mesmo na ausência de concentrações detectáveis de sulfeto. A remoção média geral de amônio (NH4+), nitrogênio total, fosfato total dissolvido e fósforo total foi de 31%, 12%, 24% e 27% respectivamente nos sistemas estudados. / The present work compared the performance of eight stabilization ponds in the Northwest region of São Paulo state, that treat predominantly the domestic sewage from eight small cities with a maximum of 5000 inhabitants (1700 links): Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Trapuã and Adolfo. The first four systems are made of four primary facultative ponds and the last four by anaerobic ponds and secondary facultative ponds. A total of twenty-five chemical, physical and biological variables were analyzed in integrated samples collected between 24/05/2000 and 03/10/2000. The bathymetric analysis performed has indicated deadlines for sludge removal from the stabilization pond bottom. Mean sludge accumulation rates o btained for anaerobic and primary facultative ponds were 0.07 and 0.14 m3/inhabt.year, respectively. Effluents from anaerobic and facultative ponds had a mean pH of 6.6 and 7.4. In anaerobic ponds a righ rate of suspended solids removal was found and the Biochemical Oxygen Demand (BOD) had an overall general efficiency of 64% and 61%, respectively. The systems did not completely attend the present legislation in respect to a BOD removal of 80%, as required, however the mean value for the eight systems monitored was 78%, very close to the established limit. It is therefore suggested that for this region, in order to attain the removal efficiency of 80% anaerobic ponds should have a residence time of 5 days and the primary and secondary facultative ones should have residence times of 25 and 15 days respectively, coupled to loading rates of 140 and 170 Kg BOD/ha.day respectively. Also, the maximum limit of 1000 fecal coliforms per 100 ml was not reached, and in general there was a mean removal efficiency of 97.40%, indicating that an additional treatment process needs to be implemented for a successful removal of coliforms. No correlation was found between the removal efficiency and morphometry (length/weight) pond characteristics. Bad smell was present even in the absence of detectable amounts of sulfide. The mean efficiency for the removal of ammonium (NH4+), total nitrogen, total dissolved phosphorus and total phosphorus were 31%, 12%, 24%, and 27% respectively, among the systems studied.
36

Avaliação dos efeitos do recebimento do lodo de estação de tratamento de água em sistema de tratamento de esgoto pelo processo de lodo ativado com aeração prolongada. / Evaluation of the effects of accepting water treatment plant residual at a wastewater system using prolongated aeration activated-sludge process.

Lucia Naomi Asada 25 May 2007 (has links)
Nesta pesquisa o principal objetivo foi estudar a influência da disposição de lodo gerado em estação de tratamento de água (ETA), que utiliza sulfato de alumínio como coagulante, nos processos biológicos de tratamento de esgoto por lodo ativado com aeração prolongada. Para isso, uma estação piloto de fluxo contínuo foi operada com idade do lodo de 25 dias em duas condições: inicialmente alimentada somente com esgoto bruto e posteriormente com adição de lodo de ETA à base de alumínio de modo a haver acréscimo nos sólidos em suspensão (SS) do esgoto em 25, 50 e 100 mg/L. Os resultados obtidos mostraram que a principal conseqüência foi o aumento na produção de sólidos do sistema (acréscimos médios de 4,6% com 25 mg/L, 37,7% com 50 mg/L e 41,0% com 100 mg/L) e, portanto, na concentração média de SS no tanque de aeração, no decantador secundário e no lodo produzido em excesso. Como o decantador secundário operou com taxa de aplicação de sólidos abaixo da taxa limite não houve problema de arraste de sólidos pelo efluente final. Não houve interferências na remoção de DBO5,20 (eficiência de remoção acima de 94%). O teste de consumo de oxigênio específico (TCOa/SSV) e o exame microscópico do lodo não apontaram possíveis efeitos tóxicos desse lodo à microfauna existente. Não houve inibição no processo de nitrificação (eficiência média de remoção de nitrogênio Kjeldhal Total e de nitrogênio amoniacal acima de 95%). Houve aumento na concentração de DQO e de SS no efluente final pela própria contribuição do lodo da ETA sobre esses parâmetros. A remoção de fósforo foi observada apenas na forma solúvel com dosagem de 25 mg/L e 50 mg/L (eficiências de remoção de 9,1% e de 21,9% respectivamente). Esses resultados apontam que a disposição do lodo de ETA a base de alumínio em sistema de lodo ativado pode ser realizada sem interferências negativas sobre esses processos biológicos aeróbios. / The main purpose of this research was to study the influence of an alum-coagulated water treatment plant (WTP) sludge on the biological processes of wastewater treatment using extended aeration activated-sludge process. For this, a continuousflow activated-sludge pilot plant was operated at solids retention time (SRT) value of 25 day under two conditions: initially, it was feeded only with sewage and next dosed with alum sludge in way to have an addition about 25, 50 and 100 mg of suspended solids (SS) per liter of incoming sewage. The results showed that the main consequence was the increase of solids production (average addition of 4,6% at 25 mg/L, 37,7% at 50 mg/L and 41% at 100 mg/L dosages) and therefore an increasing of average concentration of SS in aeration tank, secondary clarifier and wasteactivated sludge. As the secondary clarifier operated under solids loading rate limit no solids were discharged in the clarifier effluent. There was no interference on BOD5 removal (removal efficiency above 94%). The specific oxygen uptake rate (SOUR) and the microscopic observations did not show any possible toxic effects to the microbial population inhabiting the activated sludge system. There was no inhibition in nitrification process (average efficiency of Total Kjeldahl nitrogen and ammonia nitrogen removal above 95%). There was an increase of COD and SS in final effluent due to contribution of WTP residuals on these parameters. Phosphorus removal was observed only in soluble form with doses of 25 mg/L and 50 mg/L (removal efficiency of 9,1% and 21,9% respectively). These results indicate that disposal of WTP alum sludge in activated-sludge system can be done without any adverse effects on these aerobic biological processes.
37

Tratamento de águas residuárias utilizando emissários submarinos: avaliação do nível de tratamento para uma disposição oceânica ambientalmente segura. / Wastewater treatment using submarine outfalls: evaluation on the treatmente level for environmentally safe ocean disposal.

Eduardo Lucas Subtil 23 May 2012 (has links)
Tendo em vista as questões ambientais relacionadas com a disposição oceânica de esgotos sanitários, muito tem sido debatido sobre qual nível de tratamento deve ser adotado ou quais constituintes presentes nos esgotos devem ser removidos antes do lançamento em regiões costeiras. Dentro deste contexto, este estudo teve como objetivo principal fornecer subsídios para uma tomada de decisão quanto à necessidade de remoção de nutrientes para lançamento de esgotos sanitários por meio de emissários submarinos, de maneira a garantir um nível de tratamento mínimo sem que haja um comprometimento do corpo receptor em termos de potencial de eutrofização. Para isso, foram utilizados dois sistemas de disposição oceânica de esgotos sanitários: Santos/São Vicente e Praia Grande 2. O impacto ambiental do lançamento de esgotos pelos emissários submarinos foi avaliado por um modelo numérico de eutrofização, sendo as características da pluma de esgoto no campo próximo determinada pelo software CORMIX e acoplado no modelo de campo distante. A necessidade de remoção de nitrogênio e fósforo foi estimada com base na metodologia do Plano Oceânico da Califórnia. Os resultados demonstraram que tanto para o caso do emissário submarino de Santos quanto para o de Praia Grande haveria necessidade de remover amônia e fosfato para atender a legislação CONAMA 357/2005 quando operados com vazões de 3,0 e 5,3 m³.s-¹. Além disso, quando os sistemas foram operados sem tratamento ocorreu um aumento significativo na concentração de clorofila-a, atingindo valores de até 16 µg chl-a/L 12 µg chl-a/L na baía de Santos e Praia Grande, respectivamente. Os resultados demonstraram também que a utilização de um tratamento secundário com oxidação parcial da amônia promoveria uma redução de apenas 30% na concentração de clorofila-a, enquanto que a utilização de um TPQA com remoção de fosfato promoveria uma resposta ambiental melhor, levando a uma redução de até 71% na concentração de clorofila-a, resultados semelhantes ao tratamento terciário com remoção de nitrogênio e fósforo, resultados semelhantes aos obtidos quando foi considerado o tratamento terciário com remoção de nitrogênio e fósforo. / Due to environmental issues related to wastewater ocean discharge, much has been debated about the level of treatment that should be adopted or which constituents must be removed from wastewater before its final disposal in coastal zones. Within this context, this study aimed to provide support for a decision making on the need of wastewater nutrient removal before its final disposal through submarine outfalls in order to ensure an adequate treatment level, minimizing the environmental impact on the receiving body in terms of eutrophication potential. For this purpose, two wastewater ocean disposal systems: Santos/San Viciente and Praia Grande 2, were evaluated. The environmental impact of wastewater discharge through submarine outfalls was evaluated by a 2D eutrophication numerical model. Wastewater mixing conditions in the near field plume was evaluated using the software CORMIX, and the results were coupled to a far-field model. Nitrogen and phosphorus removals were evaluated through the California Ocean Plan methodology. The results showed that the removal of ammonia and phosphate is required for both submarine outfalls, Santos and Praia Grande, to meet the Brazilian legislation(CONAMA357/2005) when they are operated with flow rates of 3.0 and5.3m³.s-¹. Furthermore, when the systems are operated without treatment, modeled chlorophyll-a concentrations increased up to 16 µg chl-a/L and 12 µg chl-a/L in Santos bay and Praia Grande, respectively. The results also demonstrate that the use of a secondary treatment with partial ammonia oxidation promote a reduction of only 30% in the chlorophyll-a, while the use of a CEPT with phosphate removal promote a better environmental response, resulting a chlorophyll-a concentration reduction of 71%, similar results were obtained when tertiary treatment was considered for nitrogen and phosphorus removals.
38

Pós-tratamento de efluente de lagoa facultativa fotossintética em filtros biológicos percoladores visando remoção de nitrogênio amoniacal. / Post-treatment of photosynthetic facultative pond effluent on trickling filters in order to remove ammonia.

Mônica Medeiros 01 April 2011 (has links)
Neste trabalho, estudou-se a utilização de filtros percoladores como tratamento complementar de efluente de lagoa de estabilização visando a remoção de nitrogênio, principal causador de problemas como a eutrofização de corpos hídricos em conjunto com o fósforo. A motivação principal para o desenvolvimento desta pesquisa foi a dificuldade encontrada para o atendimento ao padrão definido pela Resolução CONAMA 357/05, a qual define concentração máxima de nitrogênio para lançamento de efluentes em corpos hídricos receptores de 20 mg/l. Em 2008 foi promulgada a Resolução CONAMA nº 397 a qual estabeleceu, em seu Artigo 34, que o padrão de emissão de nitrogênio amoniacal seria suspenso temporariamente para efluentes de estação de tratamento de esgoto sanitário, continuando a valer a concentração máxima nos corpos receptores estabelecidas na Resolução CONAMA 357/05. Sendo assim, a questão sobre a remoção de nutrientes constitui uma preocupação diretamente relacionada ao emprego dos sistemas de lagoas de estabilização. Para esta pesquisa, utilizou-se os efluentes tratados por lagoas facultativas provenientes da Estação de Tratamento de Esgoto do município de Lins/SP e, para o experimento em questão, foram construídos dois filtros biológicos seguidos de decantadores, ambos em escala piloto. Os filtros foram construídos em um corpo cilíndrico de polipropileno com diâmetro de 1,2 metros e teve seu volume dividido igualmente por uma placa vertical também de polipropileno, propiciando área superficial de 1,13 m² e volume útil total de 4,52m³. Para o fornecimento de oxigênio, indispensável para o processo de nitrificação, o filtro foi apoiado sobre uma base de concreto com drenos de fundo para permitir a ventilação do sistema, garantindo a concentração de oxigênio necessária. Para comparação da eficiência na remoção do nitrogênio, cada filtro foi preenchido com determinado tipo de material, ou seja, um filtro continha pedra britada variando de 4 a 8, admitindo-se área superficial de 70 m²/m³ e possibilitando uma área para formação de biofilme de 316,7 m², enquanto que no outro filtro foram utilizado anéis plásticos com área superficial de 100m³/m³, fornecendo 542,9 m² de área superficial para a formação de biofilme. Também foram construídos decantadores após os filtros percoladores para a remoção dos sólidos em suspensão, não sendo alvo da pesquisa em questão Tendo em vista que o molhamento de todo o material de preenchimento se faz importante para a eficiência do sistema, foi utilizado um sistema de recalque para o transporte do esgoto para o filtro, distribuído continuamente sobre o meio suporte e com vazão divida igualmente para os dois filtros por meio de um sistema de distribuição de pvc perfurado com diâmetro de 40 mm e com funcionamento semelhante a um aspersor de jardim A taxa de aplicação superficial variou entre baixa, intermediária e alta, tendo aumento de vazão no sistema até que o processo de nitrificação cessasse e cada fase teve duração de 180 dias. Conforme verificado nos resultados obtidos, filtros percoladores apresentam boa eficiência na remoção do nitrogênio do efluente, seja pela desnitrificação via nitrito ou pela volatilização do nitrogênio. A ETAPA 1 apresentou resultados bastante satisfatórios para o filtro de brita em relação ao filtro com anéis plásticos, podendo ter sido ocasionado pela área rugosa das britas, a qual facilitou a formação do biofilme, enquanto que a superfície lisa dos anéis plásticos dificulta a formação do biofilme, resultando na baixa eficiência apesar da maior área superficial. Já na ETAPA 3, com taxas de aplicação maiores, o filtro preenchido com anéis plásticos apresentou maior eficiência do que o filtro com brita. Tal fato pode ter sido conseqüência da maior área disponível para a formação do biofilme nos anéis plásticos. Ambos os casos apresentaram eficiência suficiente para remoção de nitrogênio a concentrações inferiores a 20 mg/l. Tais resultados demonstram que os filtros percoladores possuem boa funcionalidade para a remoção do nitrogênio de efluente sanitário tratado por sistemas de lagoas de estabilização. / It was studied in this paper the use of trickling filters as a complementary treatment of wastewater stabilization pond seeking removal of nitrogen, the main cause of problems such as eutrophication of water bodies in conjunction with phosphorus. The main motivation for this research was the difficulty to meet the standard set by CONAMA 357/05 Resolution, which defines the maximum nitrogen concentration for disposal of effluents in water bodies as 20 mg / l. In 2008 was created the CONAMA Resolution 397 which established, in Article 34 that the emission pattern of ammonia nitrogen would be temporarily suspended for wastewater treatment plant discharge, continuing to enforce the maximum concentration in the water bodies established in CONAMA Resolution 357/05. Thus, the question on the removal of nutrients is a concern related to the use of systems of waste stabilization ponds. For this study, was used the treated effluent by anaerobic and facultative ponds from the Sewage Treatment Plant in the city of Lins/SP, and for this experiment was constructed two trickling filters followed by settlers, both in pilot scale. The filters were constructed on a cylindrical body of polypropylene with a diameter of 1.2 meters and its volume was divided symmetrically by a vertical plate also made of polypropylene, providing superficial area of 1.13m² and total net volume of 4.52m³. To supply oxygen, essential for the nitrification process, the filter was supported on a concrete base with bottom drains to allow the ventilation system, to supply the concentration of oxygen needed. To compare the efficiency of nitrogen removal, each filter was filled with a certain type of material, ie, a filter containing crushed rock ranging from 4 to 8, considering surface area of 70m²/m³ and a possible area for biofilm formation of 316.7m², while in the other filter was used plastic rings with surface area of 100m²/m³, providing 542.9m² of surface area for biofilm formation. Settlers were constructed after the trickling filters for the removal of suspended solids, because that are not the focus of this research. Considering that the wetness around the filling material is important for system efficiency, it was used a pumping system to transport sewage to the filter, continuously distributed on the support materials and flow split equally for both filters by a distribution system made of perforated PVC with a diameter of 40mm and functioning like a garden sprinkler. The application rate surface ranged from low, intermediate and high, having increased flow in the system until the process of nitrification ended and each phase lasted 180 days. As shown in the results, trickling filters show good efficiency in removing nitrogen from wastewater, either by denitrification by nitrite or by the volatilization of nitrogen. The STEP 1 showed satisfactory results for the filter of crushed rocks over the filter with plastic rings, which may have been caused by the rocks rough area, which facilitated the formation of biofilms, while the smooth surface of the plastic rings makes harder the formation of biofilm, resulting in low efficiency despite the larger surface area. In STEP 3, with higher rates of application, the filter filled with plastic rings showed higher efficiency than the filter with crushed rocks. This might have been a consequence of the greater area available for biofilm formation in plastic rings. Both cases had efficient enough to achieve nitrogen concentrations lower than 20 mg/l. These results demonstrate that the trickling filters have good functionality for removing nitrogen from sanitary wastewater treated systems for waste stabilization ponds.
39

Estudo comparativo entre oito sistemas de lagoas de estabilização da região noroeste do Estado de São Paulo / Comparative study of eight systems of stabilization ponds in the northwestern region of São Paulo

João Luiz Cais da Silva Gomes 10 April 2002 (has links)
Este trabalho comparou oito lagoas de estabilização da região Noroeste do Estado de São Paulo, que tratam esgotos predominantemente sanitários de Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Irapuã e Adolfo, cidades pequenas, com no máximo 5500 habitantes (1700 ligações), onde os quatro primeiros sistemas são compostos apenas por lagoas facultativas primárias e os quatro últimos por lagoas anaeróbias e lagoas facultativas secundárias. Vinte e cinco variáveis físicas, químicas e biológicas foram analisadas em amostras compostas coletadas entre 24/05/2000 e 03/10/2000. A análise da batimetria efetuada fornece indicações de prazos para a remoção do lodo do fundo das lagoas. As taxas de acúmulo de lodo médias obtidas para as lagoas anaeróbias e facultativas primárias foram de 0,07 e 0,14 m3/hab.ano, respectivamente. O pH do efluente das lagoas anaeróbias e das facultativas foi em média 6,6 e 7,4. Nas lagoas anaeróbias observou-se alta remoção de sólidos suspensos e de Demanda Bioquímica de Oxigênio (DBO) com eficiência geral média de 64% e 61% respectivamente. Os sistemas não atenderam plenamente à legislação no tocante a eficiência de remoção de DBO de 80%, porém o valor médio encontrado para os oito sistemas foi de 78%, bastante próximo do exigido. Sugere-se para a região, para eficiência de remoção de DBO de 80%, lagoas anaeróbias com tempo de detenção de 5 dias e para as lagoas facultativas primárias e secundárias tempos de detenção de 25 e 15 dias respectivamente, e taxas de aplicação superficial de 140 e 130 kg DBO/ha.dia, respectivamente. Não foi atingido o limite máximo de 1000 coliformes fecais por 100 ml, obtendo-se média geral de remoção de 97,40% inferindo-se que há necessidade de um processo de tratamento complementar para a remoção de microrganismos. Não observou-se correlação entre eficiência do sistema e relação comprimento/largura das lagoas. Constatou-se maus odores mesmo na ausência de concentrações detectáveis de sulfeto. A remoção média geral de amônio (NH4+), nitrogênio total, fosfato total dissolvido e fósforo total foi de 31%, 12%, 24% e 27% respectivamente nos sistemas estudados. / The present work compared the performance of eight stabilization ponds in the Northwest region of São Paulo state, that treat predominantly the domestic sewage from eight small cities with a maximum of 5000 inhabitants (1700 links): Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Trapuã and Adolfo. The first four systems are made of four primary facultative ponds and the last four by anaerobic ponds and secondary facultative ponds. A total of twenty-five chemical, physical and biological variables were analyzed in integrated samples collected between 24/05/2000 and 03/10/2000. The bathymetric analysis performed has indicated deadlines for sludge removal from the stabilization pond bottom. Mean sludge accumulation rates o btained for anaerobic and primary facultative ponds were 0.07 and 0.14 m3/inhabt.year, respectively. Effluents from anaerobic and facultative ponds had a mean pH of 6.6 and 7.4. In anaerobic ponds a righ rate of suspended solids removal was found and the Biochemical Oxygen Demand (BOD) had an overall general efficiency of 64% and 61%, respectively. The systems did not completely attend the present legislation in respect to a BOD removal of 80%, as required, however the mean value for the eight systems monitored was 78%, very close to the established limit. It is therefore suggested that for this region, in order to attain the removal efficiency of 80% anaerobic ponds should have a residence time of 5 days and the primary and secondary facultative ones should have residence times of 25 and 15 days respectively, coupled to loading rates of 140 and 170 Kg BOD/ha.day respectively. Also, the maximum limit of 1000 fecal coliforms per 100 ml was not reached, and in general there was a mean removal efficiency of 97.40%, indicating that an additional treatment process needs to be implemented for a successful removal of coliforms. No correlation was found between the removal efficiency and morphometry (length/weight) pond characteristics. Bad smell was present even in the absence of detectable amounts of sulfide. The mean efficiency for the removal of ammonium (NH4+), total nitrogen, total dissolved phosphorus and total phosphorus were 31%, 12%, 24%, and 27% respectively, among the systems studied.
40

Despoluição do rio Tietê : questionar paradigmas para avançar

Silva, Edson Aparecido da January 2016 (has links)
Orientador: Prof. Dr. Ricardo de Sousa Moretti / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Planejamento e Gestão do Território, 2016. / Esta dissertação tem por objetivo avaliar o histórico de despoluição do rio Tietê, um dos principais rios do estado de São Paulo. O rio continua poluído, segundo indicadores que serão apresentados neste estudo, e a pesquisa desenvolvida visou levantar e debater hipóteses exploratórias que possam ajudar a esclarecer os motivos que determinam o fato de os projetos de despoluição do Tietê não terem proporcionado resultados significativos. Estas hipóteses foram levantadas a partir de entrevistas e de oficina de debates com a participação de técnicos da área de saneamento; e, para estas hipóteses, foram agregadas informações que visam alimentar o debate sobre sua pertinência. Foram levantados três blocos de questões que deram origem a oito hipóteses exploratórias apresentadas e debatidas neste trabalho: Financeiro ¿ questiona se a execução de obras de tratamento de esgotos pode ser considerada bom negócio para as finanças das companhias de saneamento. Avaliação ¿ debate o sistema de controle e cobrança de metas e resultados. Institucional ¿ analisa a articulação entre obras e interlocutores, a regulação e o controle institucional. O debate mostra a importância de avançar além das avaliações de percentuais ou volumes de esgotos coletados e tratados e a necessidade de metas de despoluição, por exemplo, em bacias e microbacias na perspectiva de obtenção de resultados mais efetivos e visíveis como forma, inclusive, de aproximar as pessoas dos corpos d¿água que cortam as cidades e que sobrevivem a céu aberto, apesar de poluídos. / This dissertation aims to evaluate the decontamination history of the Tietê River, one of the main rivers in the state of São Paulo. The river remains polluted according to indicators to be presented in this study, and the research developed aimed to raise and discuss exploratory hypotheses as a way to help understanding the reasons that determine the fact of pollution control projects Tietê River have not provided significant results. These hypotheses were developed from interviews and workshop discussions with the participation of experts in sanitation and these hypotheses were aggregated information, aimed at encouraging the debate about its relevance. Three blocks of issues that gave rise to eight exploratory hypotheses were raised, presented and discussed in this work: Financial ¿ questions whether the execution of sewage treatment works can be considered good business to finance sanitation companies. Rating ¿ debate the control system and the achievement of goals targets and results. Institutional ¿ analyzes the relationship between building works and partners, regulation and institutional control. The debate shows the importance to move beyond ratings of percentage or volumes collected and treated sewage and the need targets of decontamination, for example, in basins and micro basins in view of obtaining more effective and visible results, in order, including, to bring the people of the streams that cross the cities and they survive in the open, although polluted.

Page generated in 0.4939 seconds