• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • Tagged with
  • 120
  • 120
  • 113
  • 110
  • 99
  • 99
  • 74
  • 72
  • 38
  • 29
  • 29
  • 27
  • 23
  • 23
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desinfecção solar da água: avaliação da técnica "SODIS" aplicada a águas de chuva, poço e manancial superficial, nas condições climáticas de verão na região de Porto Alegre, RS

Carvajal, Ruth Angelic Reyes January 2015 (has links)
SODIS (Solar Water Disinfection) é uma tecnologia simples para tratamento de água no pontode- uso, sendo uma alternativa importante para disponibilizar água em situações de emergência ou onde não há acesso à água potável. A ação concomitante entre a temperatura e a radiação ultra violeta do sol provoca a morte dos microorganismos presentes na água. Este estudo avaliou a eficiência de inativação de coliformes totais e Escherichia coli pela técnica SODIS para as águas de chuva (coletada em telhado), de poço freático e de manancial superficial (reservatório), sob as condições climáticas de verão de Porto Alegre, RS. Foram ainda, realizados ensaios para verificar se ocorreu o recrescimento dos microorganismos após 24 e 48 horas do término da exposição ao sol. Também foram determinadas as constantes de decaimento das bactérias utilizando a Lei de Chick para representar o declínio dos microorganismos. Os ensaios de SODIS foram realizados em batelada, utilizando garrafas PET transparentes de 1,5 L, expostas ao sol por um período de 6 h. O mesmo número de garrafas era mantido à sombra pelo mesmo período, como controle. As temperaturas do ar e da água e a radiação ultravioleta foram monitoradas ao longo dos ensaios. Os valores médios de remoção de concentrações de E. coli no SODIS nas amostras das águas analisadas variaram entre 98,8 a maior do que 99,99%; para coliformes totais as reduções médias nas amostras variaram entre 90,00 – 99,99%. Não houve recrescimento de microorganismos após 24 e 48 horas seguindo-se ao término da exposição solar. As constantes de decaimento para coliformes totais e E. coli foram, respectivamente, 0,2979 h-1 e 0,9397 h-1, confirmando as observações de que E. coli é mais sensível a desinfecção. Os coeficientes de determinação para a equação da Lei de Chick foram de 0,938 (E. coli) e 0,877 (coliformes totais). Os resultados da pesquisa indicam que as águas de chuva e de poço freático tratadas com SODIS atingiram os padrões microbiológicos recomendados pela Organização Mundial da Saúde, o que não ocorreu com as amostras de água do reservatório superficial estudado. / SODIS (Solar Water Disinfection) is a simple techhnology for point-of-use drinking water treatment, and can be used during emergencies or in sites without running water. The joint action of high temperature and ultraviolet radiation causes the die-off of microrganisms. This study evaluated the removal of total coliforms and Escherichia coli using SODIS to disinfect water from rain (collected in roofs), from well and from surface water (reservoir) under the climate conditions of Porto Alegre, RS. Essays were also conducted to see if bacteria regrowth occurred after 24 and 48 h after the end of the SODIS test. In addition, bacterial decay coefficients were calculated using the Chick´s Law as model. SODIS essays were performed in batch reactors using 1.5 L transparent PET bottles exposed to the sunlight for 6 h.The same number of bottles were kept in the shadow, as a control. Air and water temperatures and ultraviolet radiation were monitored hourly. E. coli mean removals in samples from the three sources of water varied between 98,8% to greater than 99,99%. The mean reductions for total coliforms varied between 90.0% to 99.99%. Microorganism regrowth was not observed after 24 and 48 h. Decay coefficients for coliforms and E. coli were, respectively, 0.2979 h-1 e 0.9397 h-1, confirming the observation that E. coli is more sensitive than total coliforms to SODIS. Coefficients of determination for Chick´s Law equation were 0.938 (E. coli) and 0.877 (total coliform). The results from this research indicate that water from rain and well , but not reservoir, achieved the World´s Health Organization drinking water guidelines for drinking water with low risk of disease acquisition.
32

Estudo do comportamento da DBO em suporte aeróbio de oxigênio puro: coeficientes cinéticos e fatores de correlação / I study of the behavior of DBO in support aerobic of pure oxygen: kinetic coefficients and correlation factors

Barbosa, João Marcelo do Nascimento January 2003 (has links)
Made available in DSpace on 2012-09-06T01:11:30Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 598.pdf: 9014270 bytes, checksum: 50ddc5b9b9f3b1a57694ee2b65989074 (MD5) Previous issue date: 2003 / Os sistemas de tratamento de esgotos por lodos ativados, utilizando como suporte aeróbio o oxigênio puro, vem sendo utilizados cada vez com maior freqüência no tratamento de efluentes industriais e, recentemente, no tratamento de esgotos domésticos. No dimensionamento destes sistemas de tratamento tem sido utilizada uma DBO, que utiliza oxigênio puro como suporte aeróbio, que reflete de forma mais realista a eficiência destes sistemas na remoção da matéria orgânica biodegradável. Apesar da grande importância desta DBO modificada não há referências na literatura sobre a sua cinética. Neste trabalho foi estudada a diferença entre os coeficientes cinéticos e os graus de eficiência na remoção da matéria orgânica biodegradável, de um sistema que utilize para análise de DBO um suporte aeróbio tradicional (DBOt), e de outro que utilize oxigênio puro como suporte aeróbio (DBOm). A metodologia operacional desta pesquisa foi baseada na realização de análises para avaliação do comportamento da DBO, quando em meio de ar atmosférico ou em meio de oxigênio puro através da incubação por cinco dias a 20oC e com leitura de oxigênio dissolvido, realizada diariamente, pelo método Winkler. Os resultados das análise demonstraram significativa diferença entre os valores da DBOt e da DBOm, foi obtido um fator de correlação da razão DBOm/DBOt de 1,523 mais ou menos 0,103, demonstrando um aumento da eficiência na remoção da matéria orgânica de cerca de 50 por cento, pelo uso do oxigênio nas condições do ensaio. Através destes resultados obtidos, foram calculados os coeficientes cinéticos (K) associados à redução da DBO; tanto tradicional (DBOt) quanto modificada (DBOm). Além dos aspectos técnicos dos sistemas de tratamento com oxigênio puro, descritos sucintamente neste trabalho, foi realizada uma investigação das aplicações destes sistemas no Brasil, com ênfase em sua evolução histórica entre as décadas de oitenta e noventa. Nesta pesquisa, de cunho mercadológico, da evolução histórica desta técnica de tratamento, foi realizada uma pesquisa de campo com entrevistas aos gerentes de marketing das empresas que fabricam sistemas de aeração com oxigênio puro para tratamento de efluentes. Como resultado desta investigação, é apresentado no capítulo três um consolidado de caráter qualitativo.
33

Viabilidade do uso de efluentes tratados por zona de raízes na irrigação: estudo de caso na Vila Dois Rios - Ilha Grande, RJ / Constructed of the use of efluente treated by try to use it in irrigation: case study in the Vila Dois Rios - Ilha Grande, RJ

Kaczala, Fábio January 2005 (has links)
Made available in DSpace on 2012-09-06T01:12:43Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 830.pdf: 2200736 bytes, checksum: 944e99d433e4bb3d4d9dc05ec86761f1 (MD5) Previous issue date: 2005 / A escassez de água doce, atualmente está gerando diversos tipos de problemas, devido aos usos múltiplos e demanda crescente, principalmente para as necessidades fisiológicas humanas, e atividades econômicas como a indústria, e a irrigação para produção de alimentos. Os países mais atingidos por esta escassez buscam alternativas de. Uma destas alternativas são as águas residuárias tratadas. Atualmente a atividade humana que representa o maior consumo de água é a irrigação, o que a torna a atividade com maior necessidade de recursos alternativos. O uso de águas residuárias para a irrigação, requer uma qualidade microbiológica e físico-química que não traga riscos ao meio ambiente e principalmente à saúde pública. O presente trabalho teve como objetivo analisar a qualidade microbiológica e físico-química do efluente de um sistema de tratamento biológico de esgotos domésticos de pequeno gerador utilizando o processo de Zona de Raízes como polimento final, e a viabilidade de utilizá-lo para a irrigação de acordo com algumas diretrizes existentes para proteção à saúde pública. Foram analisados alguns parâmetros, sendo que os de maior importância para a saúde pública foram os parâmetros biológicos Escherichia coli e ovos de Helmintos, além do indicador coliforme totais. O sistema foi analisado em um período de 6 meses e demonstrou viabilidade para a aplicação e utilização do efluente na irrigação, principalmente para fins de culturas industrialmente processadas, silvicultura, plantas forrageiras, culturas frutíferas arbóreas e também de cereais.
34

Desinfecção solar da água: avaliação da técnica "SODIS" aplicada a águas de chuva, poço e manancial superficial, nas condições climáticas de verão na região de Porto Alegre, RS

Carvajal, Ruth Angelic Reyes January 2015 (has links)
SODIS (Solar Water Disinfection) é uma tecnologia simples para tratamento de água no pontode- uso, sendo uma alternativa importante para disponibilizar água em situações de emergência ou onde não há acesso à água potável. A ação concomitante entre a temperatura e a radiação ultra violeta do sol provoca a morte dos microorganismos presentes na água. Este estudo avaliou a eficiência de inativação de coliformes totais e Escherichia coli pela técnica SODIS para as águas de chuva (coletada em telhado), de poço freático e de manancial superficial (reservatório), sob as condições climáticas de verão de Porto Alegre, RS. Foram ainda, realizados ensaios para verificar se ocorreu o recrescimento dos microorganismos após 24 e 48 horas do término da exposição ao sol. Também foram determinadas as constantes de decaimento das bactérias utilizando a Lei de Chick para representar o declínio dos microorganismos. Os ensaios de SODIS foram realizados em batelada, utilizando garrafas PET transparentes de 1,5 L, expostas ao sol por um período de 6 h. O mesmo número de garrafas era mantido à sombra pelo mesmo período, como controle. As temperaturas do ar e da água e a radiação ultravioleta foram monitoradas ao longo dos ensaios. Os valores médios de remoção de concentrações de E. coli no SODIS nas amostras das águas analisadas variaram entre 98,8 a maior do que 99,99%; para coliformes totais as reduções médias nas amostras variaram entre 90,00 – 99,99%. Não houve recrescimento de microorganismos após 24 e 48 horas seguindo-se ao término da exposição solar. As constantes de decaimento para coliformes totais e E. coli foram, respectivamente, 0,2979 h-1 e 0,9397 h-1, confirmando as observações de que E. coli é mais sensível a desinfecção. Os coeficientes de determinação para a equação da Lei de Chick foram de 0,938 (E. coli) e 0,877 (coliformes totais). Os resultados da pesquisa indicam que as águas de chuva e de poço freático tratadas com SODIS atingiram os padrões microbiológicos recomendados pela Organização Mundial da Saúde, o que não ocorreu com as amostras de água do reservatório superficial estudado. / SODIS (Solar Water Disinfection) is a simple techhnology for point-of-use drinking water treatment, and can be used during emergencies or in sites without running water. The joint action of high temperature and ultraviolet radiation causes the die-off of microrganisms. This study evaluated the removal of total coliforms and Escherichia coli using SODIS to disinfect water from rain (collected in roofs), from well and from surface water (reservoir) under the climate conditions of Porto Alegre, RS. Essays were also conducted to see if bacteria regrowth occurred after 24 and 48 h after the end of the SODIS test. In addition, bacterial decay coefficients were calculated using the Chick´s Law as model. SODIS essays were performed in batch reactors using 1.5 L transparent PET bottles exposed to the sunlight for 6 h.The same number of bottles were kept in the shadow, as a control. Air and water temperatures and ultraviolet radiation were monitored hourly. E. coli mean removals in samples from the three sources of water varied between 98,8% to greater than 99,99%. The mean reductions for total coliforms varied between 90.0% to 99.99%. Microorganism regrowth was not observed after 24 and 48 h. Decay coefficients for coliforms and E. coli were, respectively, 0.2979 h-1 e 0.9397 h-1, confirming the observation that E. coli is more sensitive than total coliforms to SODIS. Coefficients of determination for Chick´s Law equation were 0.938 (E. coli) and 0.877 (total coliform). The results from this research indicate that water from rain and well , but not reservoir, achieved the World´s Health Organization drinking water guidelines for drinking water with low risk of disease acquisition.
35

Tratamento conjugado de águas residuárias e lixiviado de aterro sanitário em lagoas de estabilização rasas

Lima, Diego de Farias 10 December 2010 (has links)
Made available in DSpace on 2015-09-25T12:20:28Z (GMT). No. of bitstreams: 1 PDF - Diego de Farias Lima.pdf: 500606 bytes, checksum: 2206e3883002ebc768ec98e9430f7666 (MD5) Previous issue date: 2010-12-10 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / In recent decades there has been increasing concern about water resources due to population growth, increases in water demand and the degradation of water bodies through the release of domestic and industrial wastewater without adequate treatment. In addition to these problems, municipal solid waste (MSW) produces another source of pollution, namely, leachate emanating from sanitary landfill. This study investigated the treatment of wastewater and landfill leachate in 4 series of shallow waste stabilization ponds located at the Experimental Research Station for Biological Sewage Treatment (EXTRABES), of the State University of Paraiba, Campina Grande, Paraiba, Brazil. The experimental system received sewage from the eastern sewerage interceptor of Campina Grande and leachate collected from the sanitary landfill of the city of Joao Pessoa, PB, and pretreatment by process of "ammonia stripping" in a series of shallow lagoons. The experimental period was divided into three phases, depending on the mixtures of substrate used to feed the pond system. In Phase 1, the substrate was only wastewater, in Phase 2, the substrate was comprised a mixture of wastewater and pretreated leachate in a ratio of 99:1, respectively, and in Phase 3 the ratio of sewage to leachate was 98:2. The removal efficiency of organic material indirectly measured as COD and BOD5 in Phase 1 was 29% and 91% in Phase 2, 54% and 95% and in Phase 3 83% and 90 %, respectively. Regarding species richness of microalgae, there was an increase in the number of species along the stabilization pond system, with 12 algal species in the first pond and 29 species in the final pond. The class Euglenophyceae was predominant in ponds 1 and 2, and Chlorophyceae in ponds 3 and 4. The algal density in pond 4, in relation to pond 1 decreased by 82% in Phase 2 and by 92% in Phase 3. The pH and dissolved oxygen levels in the ponds were highest during the day, between 10 e 16 h, with pH above 9,2 and dissolved oxygen above 14 mg/L in pond 2. The combined treatment of wastewater and landfill leachate in a series of shallow ponds would appear to be a promising alternative technology for the future, providing social, economic and environmental advantages, mainly for geographical regions with favorable availability of areas. / Nas últimas décadas houve crescente preocupação com os recursos hídricos, em relação ao crescimento da população, aumentou a demanda por água e a degradação dos corpos d água através da liberação de efluentes domésticos e industriais sem tratamento adequado. Além desses problemas, os resíduos sólidos urbanos (RSU) produzem outra fonte de poluição, designadamente, o lixiviado proveniente dos aterros sanitários. Este estudo investigou o tratamento de águas residuárias e lixiviado de aterro sanitário em uma série de quatro lagoas de estabilização rasas localizado na Estação Experimental de Tratamento Biológico de Esgoto Sanitário (EXTRABES), da Universidade Estadual da Paraíba, Campina Grande, Paraíba, Brasil. O sistema experimental recebeu o esgoto do emissário leste do sistema de esgotamento da cidade de Campina Grande e lixiviado coletado no aterro sanitário da cidade de João Pessoa, PB, e pré-tratado por processo de stripping amônia em uma série de lagoas rasas. O período experimental foi dividido em três fases, dependendo das misturas de substratos usados para alimentar o sistema de lagoas. Na Fase 1, o substrato foi apenas águas residuárias, na Fase 2, o substrato foi composto por uma mistura de águas residuárias e lixiviado pré-tratado em uma proporção de 99:1, respectivamente, e na Fase 3 a proporção de esgoto para lixiviado foi 98:2. A eficiência de remoção de material carbonáceo medido indiretamente como DQO e DBO5 na Fase 1 foi 29% e 91%, na Fase 2 de 54% e 95% e na Fase 3 de 83% e 90%, respectivamente. Quanto à riqueza de espécies de microalgas, houve um aumento no número de espécies ao longo do sistema de lagoas de estabilização, com 12 espécies de algas na primeira lagoa e 29 espécies na lagoa final. A classe Euglenophyceae foi predominante nas lagoas 1 e 2, e Chlorophyceae nas lagoas 3 e 4. A densidade de algas na lagoa 4, em relação à lagoa 1 diminuiu em 82% na Fase 2 e 92% na Fase 3. O pH e oxigênio dissolvido nos corpos d'água foram maiores durante o dia, entre 10 e 16h, com pH acima de 9,2 e oxigênio dissolvido acima de 14 mg/L na lagoa 2. O tratamento conjugado de águas residuárias e lixiviado de aterro sanitário em lagoas de estabilização rasas, parece ser uma promissora tecnologia alternativa para o futuro, proporcionando benefícios sociais, econômicos e ambientais, principalmente para regiões geográficas com disponibilidade de áreas favoráveis.
36

Adsorção e fotodegradação de corantes, amarelo crepúsculo e azul brilhante, para tratamento de efluentes de indústrias alimentícias / Adsorption and photodegradation of dyes, sunset yellow and brilliant blue for wastewater treatment in the food Industry

Sá, Fernando Pereira de 26 April 2013 (has links)
Submitted by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-27T17:29:58Z No. of bitstreams: 2 Tese - Fernando Pereira de Sá - 2013.pdf: 8738868 bytes, checksum: 9f42680dbf9fa83e0629a95d1143277c (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luanna Matias (lua_matias@yahoo.com.br) on 2015-03-30T12:24:45Z (GMT) No. of bitstreams: 2 Tese - Fernando Pereira de Sá - 2013.pdf: 8738868 bytes, checksum: 9f42680dbf9fa83e0629a95d1143277c (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-30T12:24:45Z (GMT). No. of bitstreams: 2 Tese - Fernando Pereira de Sá - 2013.pdf: 8738868 bytes, checksum: 9f42680dbf9fa83e0629a95d1143277c (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-04-26 / Effluents that are discarded by food industry are important sources of water pollution, as they may contain high concentrations of organic matter and intense color. We used the technique of design of experiments to evaluate the influence of some variables in the study of adsorption of food colors, sunset yellow and brilliant blue. The “batch” method was used to assess the effects of variaable: contact time, pH0 and concentration of the adsorbate in the adsorption process of colors in hydroxide double layered system CaAl-LDH-NO3. The LDH was synthesized by coprecipitation at pH variable and characterized by X-ray diffraction, infrared spectroscopy, electron microscopy scanning thermogravimetric analysis, zeta potential, surface area and pore volume. adsorption assays were performed as a function of contact time, pH0, dye concentration and temperature. Results showed that the pH affects the surface charge of the adsorbent and the degree of dissociation of the anionic dyes. Among the initial pHs (4 and 10) for sunset yellow and (6 and 10) to brilliant blue, as the pH0 increases, decreases the amount of dye removed. Langmuir equation was that more adequately described the equilibrium data, obtaining a maximum adsorption of 398.41 mg/g for sunset yellow and 108.23 mg/g for brilliant blue. In the process of photodegradation by direct photolysis using ultraviolet radiation, the efficiency of decolourisation percentages reached 98 % for the yellow dye twilight and 97 % to bright blue. The absorbance spectra for two samples of colorants showed a decrease of characteristic absorption bands of these materials throughout the irradiation time. The photodegradation was also performed on solid after adsorption, the visually observable discoloration of the material and confirming the degradation process by XRD. Adsorption, and photodegradation were effective also in the treatment of synthetic effluent (mixture the dyes sunset yellow and brilliant blue), presenting virtually the same kinetics observed for removing discoloration of dyes individually. / Efluentes que são descartados pelas indústrias de alimentos são importantes fontes de poluição da água, pois podem conter grandes concentrações de matéria orgânica e coloração intensa. Foi utilizada a técnica do planejamento de experimentos para avaliar a influência de algumas variáveis no estudo de adsorção dos corantes alimentícios, amarelo crepúsculo e azul brilhante. O método de “batelada” foi utilizado para avaliar os efeitos das variáveis: tempo de contato, pH0 e concentração do adsorvato, no processo de adsorção dos corantes em hidróxido duplo lamelar do sistema HDL-CaAl-NO3. O HDL foi sintetizado por coprecipitação em pH variável e caracterizado por difração de raios X, espectroscopia no infravermelho, microscopia eletrônica de varredura, análise termogravimétrica, potencial zeta, área superficial e volume de poros. Ensaios de adsorção foram realizados em função do tempo de contato, do pH0, da concentração de corante e da temperatura. Os resultados mostraram que o pH afeta a carga superficial do adsorvente e o grau de dissociação dos corantes aniônicos. Entre os pHs iniciais (4 e 10) para amarelo crepúsculo e (6 e 10) para azul brilhante, a medida que aumenta o pH0, diminui a quantidade de corante removido. A equação de Langmuir foi a que descreveu mais adequadamente os dados de equilíbrio, obtendo uma adsorção máxima de 398,41 mg/g para amarelo crepúsculo e 108,23 mg/g para azul brilhante. No processo de fotodegradação utilizando fotólise direta por radiação ultravioleta, a eficiência de descoloração alcançou percentuais de 98 % para o corante amarelo crepúsculo e 97 % para azul brilhante. Os espectros de absorbância para as amostras dos dois corantes mostraram uma diminuição das bandas de absorção características destes materiais no decorrer do tempo de irradiação. A fotodegradação também foi realizada no sólido após adsorção, sendo observado visualmente a descoloração do material e confirmando o processo de degradação por DRX. A adsorção e a fotodegradação foram eficazes, também, no tratamento do efluente sintético (mistura dos corantes amarelo crepúsculo e azul brilhante), apresentando praticamente a mesma cinética de descoloração observada para a remoção dos corantes individualmente.
37

Uso da solarização na redução de microrganismos patogênicos no efluente doméstico

Eliana Maria de Araújo Mariano da Silva 13 September 2007 (has links)
Solarização é uma alternativa para desinfecção de águas residuárias, pois a ação conjunta dos raios solares e da temperatura tende a inibir o crescimento de microrganismos. O objetivo desta pesquisa é verificar a eficácia do método na redução de microrganismos patogênicos em amostras de efluente doméstico. O experimento foi desenvolvido em condições de campo nos meses de julho, agosto, outubro e dezembro de 2006 e março e julho de 2007, na área da estação meteorológica localizada na Fazenda Piloto da Universidade de Taubaté. A análise de coliformes fecais e a leitura de turbidez foram realizadas no laboratório de Microbiologia Agrícola e Fitopatologia do Departamento de Ciências Agrárias da Universidade de Taubaté. A temperatura do ar e a intensidade da radiação solar total acumulada foram fornecidas pela Plataforma de Coleta de Dados (PCD) uma parceria UNITAU e INPE através do Programa de Monitoramento Ambiental da Região do Eixo Rio-São Paulo. As amostras de efluentes foram condicionadas em 20 garrafas transparentes com capacidade para 2L tipo PET (Politereflato de Etileno), depois submetidas aos seguintes procedimentos: sem exposição ao sol e com 2, 4, 6 e 8 horas de exposição ao sol, com 4 repetições cada, totalizando 20 recipientes. A eficiência do tempo de exposição foi determinada pela quantificação do Número Mais Provável (NMP) para coliformes fecais nas amostras de efluentes. Quanto ao resultado podese observar que a exposição do efluente a radiação solar reduziu a ocorrência de coliformes fecais, na medida em que se aumentou o tempo de exposição. Sendo que para 2 horas de exposição à radiação solar houve uma redução média de 51,2% e com 8 horas de exposição essa média aumentou para 84% de redução para coliformes fecais. De acordo com os resultados pôde-se concluir que a solarização poderá ser utilizada para reduzir microrganismos patogênicos no efluente doméstico. / Solarization is an alternative method for disinfection of wastewater, therefore the joint action of the solar rays and the temperature tends to inhibit the growth of microorganisms. The objective of this research is to verify the effectiveness of the method for the reduction of pathogenic microorganisms in domestic effluent samples. The experiment was developed in field conditions during the months of August, October and December of 2006 and March and July of 2007, in the area of the meteorological station located in the Pilot Farm of the University of Taubate. The fecal coliform counts and the turbidity readings were performed in the Agricultural Microbiology and Phytopathology Laboratory of the Agrarian Sciences Department of the University of Taubate. The air temperature and the intensity of the accumulated total solar radiation had been supplied by the Data Collection Platform (DCP), a partnership between UNITAU and INPE for the Program of Environmental Monitoring of the Rio-Sao Paulo Region. The effluent samples had been placed inside of 20 transparent 2-liter disposable bottles, and than submitted to the following procedures: without exposition to the sun and with 2, 4, 6 and 8 hours of exposition to the sun, four repetitions each, totalizing 20 experiments. The efficiency of the exposition time was determined by the fecal coliform counts in the effluent samples enumerated by the most probable number (MPN) method. It can be observed reduction of fecal coliform counts with the exposition of the effluent to the solar radiation, and this reduction was proportional to the increasing of the exposition time. It was observed an average reduction for fecal coliform counts of 51,2% with 2 hours of solar radiation exposition, and this average reduction increased to 84% with 8 hours of exposition. The results showed that the solarization can be used as a method for reduction of pathogenic microorganisms in the domestic effluent.
38

Análise do desempenho hidroenergético de sistemas de abastecimento de água do município de Marabá

RODRIGUES, Rubens Chaves 01 February 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-08T22:47:39Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseDesempenhoHidroenergetico.pdf: 2412575 bytes, checksum: 8a6b978af953514358bacf8ba5cd7df9 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-13T15:01:34Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseDesempenhoHidroenergetico.pdf: 2412575 bytes, checksum: 8a6b978af953514358bacf8ba5cd7df9 (MD5) / Made available in DSpace on 2013-03-13T15:01:34Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseDesempenhoHidroenergetico.pdf: 2412575 bytes, checksum: 8a6b978af953514358bacf8ba5cd7df9 (MD5) Previous issue date: 2012 / Análise do desempenho hidroenergético de Sistemas de Abastecimento de Água do Município de Marabá/PA, gerenciados pela Unidade de Negócios Tocantins (UNITO), da Companhia de Saneamento do Pará – COSANPA. O estudo foi realizado em 3 fases, tendo informações do Sistema Nacional de Informações sobre Saneamento (SNIS) e da COSANPA. Na fase 1 foi analisada a rotina operacional de abastecimento de água do sistema Nova Marabá - Cidade Nova (16.738 ligações) e do sistema Marabá Pioneira (2.093 ligações) no ano 2010, com ênfase nos volumes produzidos de água e no consumo e custo de energia elétrica; na Fase 2 foram determinados indicadores de desempenho hidroenergético; finalizando, na fase 3 é proposto procedimentos para a melhoria da gestão hidroenergética. Na pesquisa foi verificado que o volume total produzido de água de 15,8 milhões m³/ano requereu 8.817 MWh/ano, resultando em despesa de R$ 2 milhões/ano de energia elétrica, que foi o segundo maior item das despesas de exploração (32,2%) da COSANPA no município de Marabá. A despesa de energia elétrica por ligação foi de R$ 9,32/lig. ano e R$ 7,66/lig. ano nos sistemas da Nova Marabá – Cidade Nova e da Marabá Pioneira, respectivamente, com preço médio global do kWh consumido e despesa média de energia elétrica por metro cúbico de água produzido na Nova Marabá - Cidade Nova (0,23 R$/kWh e 0,14 R$ /m³) e da Marabá Pioneira (0,21 R$/kWh e 0,07 R$/m³), ocorrendo variação dos índices de intensidade energética (kWh/m³) nos SAA. Com o trabalho é proposto procedimentos para aumentar a eficiência do controle hidroenergético na operação dos sistemas, como setorização, macromedição, micromedição, automação, o que trará reflexos positivos na redução dos custos para o abastecimento de água no município de Marabá/PA. / Analysis of the performance of hydroelectric Water Supply Systems in the city of Maraba / PA, managed by the Business Unit Tocantins (UNITA), the Sanitation Company of the Para. The study was conducted in three phases, with information from the National Information System on Sanitation (NHIS) and COSANPA. In phase one was operating the routine analysis of water supply system Nova Maraba - Nova Maraba (16,738 links) and system Maraba Pioneira (2093 links) in the year 2010, with emphasis on production volumes and consumption of water and energy cost electric, in Phase 2 were determined performance indicators hydropower; ending in Phase 3 was proposed procedures for improving the management hydropower. In the survey it was found that the total volume of water produced 15.8 million m³/year required 8,817 MWh / year, resulting in spending of $ 2 million / year of electricity, which was the second largest item of operating expenses (32.2%) of COSANPA in the city of Maraba. The cost of electricity by binding to R$ 9.32 / R$ 7.66 and link / connection systems in the Nova Maraba – Cidade Nova an d Maraba Pioneira, respectively, with overall average price per kWh consumed and average expenditure of energy per cubic meter of water produced in Nova Maraba – Cidade Nova (R$ 0.23 / kWh and R$ 0.14 /m³) and Maraba Pioneira (R$ 0.21 / kWh and R$ 0.07 / m³), occurring variation in rates of energy intensity (kWh/m³) in the SAA. With the work procedures are proposed to increase the control efficiency in the operation of hydroelectric systems, such as sectorization, macro-measurement, micro-measurement, automation, which will bring positive impact in reducing costs for water supply in the city of Maraba/PA.
39

Projeto e Opera??o em Escala Semi-Industrial de um Equipamento para Tratamento de ?guas Produzidas na Ind?stria do Petr?leo Utilizando Nova Tecnologia: misturador-decantador ? invers?o de fases - MDIF

Fernandes J?nior, Wilaci Eutr?pio 19 December 2006 (has links)
Made available in DSpace on 2014-12-17T15:01:42Z (GMT). No. of bitstreams: 1 WillaciEFJ.pdf: 1499759 bytes, checksum: 03aff567e782194c97d56cdcac63888c (MD5) Previous issue date: 2006-12-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The aim of this work is to use a new technology in the treatment of produced wastewaters from oil industry. An unit for treat produced waters called UTMDIF, was designed, installed and operated in an industrial plant for treatment of effluents from oil industry. This unit operates by means of the method of separation of phase inversion and can become a promising alternative to solve the problem of oil/water separation. This method constitutes the basis of the working of a new design of mixersettler of vertical configuration which occupies small surface area. The last characteristic becomes specially important when there is limitation on the lay-out of the plant, for example, over maritime platforms to explore oil. This equipment in a semi-industrial scale treats produced wastewaters contaminated with oil at low concentrations (ranging from 30 to 150 mg/L) and throughputs of 320 m3/d (47,4 m3 m-2 h-1). Good results were obtained in oil/water separation which leads to the necessary specification to discharge those wastewaters. Besides, the non dependence of the efficiency of separation in spite of the salinity of the medium becomes the equipment an attractive new technology to treat wastewaters containing oil at low concentrations / Este trabalho tem por objetivo utilizar uma nova tecnologia no tratamento de ?guas produzidas da ind?stria do petr?leo. Uma Unidade de Tratamento de ?guas Produzidas, denominada UT-MDIF, foi projetada, instalada e operou dentro de uma planta industrial de tratamento de efluentes de petr?leo. Esta Unidade de Tratamento piloto utiliza o m?todo de separa??o ? invers?o de fases e pode se tornar numa alternativa promissora para resolver o problema de separa??o ?leo/?gua. Este m?todo constitui a base do funcionamento de um novo modelo de misturador-decantador de configura??o vertical e que ocupa pequena ?rea superficial. Esta ?ltima caracter?stica se torna especialmente importante, quando existe limita??o de espa?o no lay-out da planta industrial, por exemplo, uma plataforma mar?tima para explora??o de petr?leo. Este equipamento em escala semi-industrial trata ?guas produzidas contaminadas com petr?leo em baixas concentra??es da ordem de 30 a 150 mg/L e vaz?es efetivas de 320 m3/d (47,4m3m-2h-1). Os bons resultados na separa??o ?leo/?gua, obtendo-se a especifica??o necess?ria para descarte, associado ? n?o depend?ncia da efici?ncia de separa??o face ? salinidade do meio, podem tornar o equipamento uma nova tecnologia no tratamento de ?guas contaminadas com ?leo a baixas concentra??es
40

Estruturação de processo de decisão sobre modelo de gestão de serviços de água e esgoto por AHP (analytic hierarchy process) / Organization of decision process about management model in water service and sewage using AHP (analytic hierarchy process)

Cavelagna, Tiago 27 January 2016 (has links)
O marco regulatório do saneamento básico no Brasil estabelece de forma clara as diretrizes que deverão ser seguidas pelos prestadores destes serviços de água e esgoto, porém quando a Constituição Federal delega aos municípios a titularidade destes serviços impõe aos decisores locais a atribuição escolha do modelo de gestão a ser adotado. As características próprias de cada município e região junto a necessidade da ponderação de atributos técnicos, econômicos e sociais de cada opção de modelo de gestão conferem elevada complexidade ao processo de decisão de qual o melhor modelo de gestão para cada município, constituindo em tema contemporâneo de estudos e de intensos debates pela população. Em função dessa complexidade, os métodos multicritérios de apoio à decisão se apresentam como ferramentas de auxílio aos tomadores de decisão tanto na estruturação destes problemas com objetivos conflitantes como também de suporte na priorização dos principais critérios envolvidos neste processo. Este estudo buscou estruturar processo de tomada de decisão sobre a escolha de modelo de gestão de serviços de água e esgoto com a priorização de critérios por meio do processo de hierarquia analítica (AHP). A partir das informações obtidas do SNIS-Sistema Nacional de Informações sobre Saneamento, nove critérios foram estabelecidos e enviados à nove especialistas para validação da seleção e priorização. Os resultados apontaram nítida priorização de critérios técnicos e operacionais, seguidos dos associados a regulação e controle social e, menos prioritários, os critérios econômicos e financeiros. / The regulatory framework of basic sanitation in Brazil, establishes very clearly the guidelines that must be followed by these service providers of water and sewage, but when the Federal Constitution delegates to the municipalities the title transfer of these services, it imposes to the local decision makers the choice of management model to be adopted. Each municipality and region own characteristics, with the necessity of weighting of technical, economic and social attributions of each option of management model confers high complexity to the decision process of which management model is best for each municipality, composing a contemporary theme for studies and intense debating by the population. Because of this complexity, the multi-criteria methods of support to the decision serve as helping tools to the decision makers not only in the structuration of these problems with confliction objects but also as support in the prioritizing of the main criteria involved in this process. This study tried to structure the process of decision making about the choice of management model for services of water and sewage with the prioritizing of criteria through the Analytic Hierarchy Process. (AHP). From the information obtained by the SNIS (Sanitation Information National System), nine criteria were established and sent to nine experts for validation of the selection and prioritizing. The results show a clear prioritizing of technical and operational criteria, followed by those associated to the regulation and social control, and, less prioritized, the financial and economic criteria.

Page generated in 0.1112 seconds