• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 1
  • Tagged with
  • 36
  • 36
  • 36
  • 29
  • 19
  • 18
  • 15
  • 15
  • 10
  • 9
  • 9
  • 9
  • 8
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Emprego de coagulante à base de tanino em sistema de pós-tratamento de efluente de reator UASB por flotação / Use of tannin-based coagulant in exhaust post-treatment of UASB reactor effluent by flotation

Pelegrino, Eloá Cristina Figueirinha 03 June 2011 (has links)
O presente trabalho teve como objetivo principal a avaliação da eficiência de remoção de carga orgânica, fósforo e sólidos em suspensão de sistema de flotação tratando esgoto sanitário pré-tratado em reatores UASB, da ETE Monjolinho da cidade de São Carlos/SP, e coagulado com tanino associado ou não a polímeros sintéticos. Os ensaios com variação de dosagem de coagulante Tanino e polímeros (polímero catiônico, polímero não-iônico e polímero aniônico) foram realizados em escala de laboratório, com o uso do equipamento flotateste. Em todos os ensaios foram fixados os valores de gradiente de velocidade na mistura rápida (800/s) e na floculação (90/s), ao tempos de detenção na mistura rápida (20 s) e na floculação (15 min) e, a pressão de saturação 5 Bar e a razão de recirculação (17%). Durante os ensaios com unidade de flotação em escala de bancada foram avaliados três valores de velocidades de flotação: 12,0 cm/min, 16,0 cm/min e 20,0 cm/min. Os ensaios foram divididos em duas fases: a fase 1 teve como objetivo analisar a resposta do sistema de flotação com o emprego do coagulante Tanino no tratamento do efluente do reator UASB da ETE Monjolinho (fase 1A) e também determinar as duas dosagens do coagulante Tanino mais adequadas para o tratamento do efluente de UASB da ETE Monjolinho para cada polímero testado (fase 1B). As fases 1A e 1B foram realizadas com efluente coletado às 8:00 h e 14:00 h, respectivamente. A fase 2 teve como objetivo a busca da dosagem ótima de tanino dentro de uma faixa mais estreita de valores, assim como a verificação do melhor tipo e dosagem de polímero sintético (não-iônico, aniônico e catiônico) para ser associado ao coagulante tanino. Na fase 1A, verificou-se que a flotação foi efetiva para remoção de cor aparente mesmo para dosagem nula de coagulante Tanino. Quanto à turbidez, verificou-se efeito marcante da adição de dosagem crescente de coagulante no aumento da eficiência de remoção desse parâmetro. Após a obtenção dos resultados da fase 1B, foram escolhidas para a fase 2 as duas menores dosagens de coagulante capazes de promover redução da turbidez em pelo menos 85%. Além destas duas dosagens, foram avaliados na fase 2 outras 3 dosagens compreendidas entre elas. Sendo assim, na fase 2 foram estudadas as doses de 65, 75, 85, 95 e 105 mg/L de coagulante, cada qual associada a seis dosagens de cada um dos polímeros estudados. Entre os tratamentos empregados, pôde-se verificar maior eficácia do polímero não-iônico e do polímero catiônico para o tratamento por flotação, associado ao coagulante tanino. O conjunto de dosagem de coagulante tanino e polímero mais vantajoso, ou seja, menor dosagem de tanino que, associada a polímero, apresentou remoção satisfatória dos parâmetros estudados, foi 65 mg/L de Tanino e 2,0 mg/L de polímero catiônico, atingindo remoções de 95,2% de turbidez (Residual de 3,65 NTU), 82,1% de cor aparente (Residual de 98 mgPT/L), 49,2% de fósforo total (Residual de 3,2 mg/L), 80,7% de DQO (Residual de 25 mg/L) e 87,9 % de SST (Residual de 13 mg/L) nas condições encontradas na época dos ensaios, para o pós-tratamento por flotação de efluente de reator UASB da ETE Monjolinho, São Carlos/SP. / The main objective of this work is the evaluation of the efficiency of removal of organic load, phosphorus and suspended solids in the flotation system treating domestic wastewater pretreated in UASB reactors, of the Monjolinho Wastewater Treatment Plant (WWTP) of Sao Carlos, SP and clotted with tannin alone or combined with synthetic polymers. Tests varying tannin dosage of coagulant and polymer (cationic polymer, nonionic polymer and anionic polymer) were performed on a batch scale, using flotatest. In all the tests were fixed the values of rapid mix (800/s) and flocculation (90/s) velocity gradients, the rapid mix (20 s) and flocculation (15 min) times, saturation pressure (5 Bar) and recycle rate (17%). During the test in the flotation bench scale unity three values of flotation velocities were evaluated: 12.0 cm/min, 16.0 cm/min and 20.0 cm/min. The tests were divided in two phases: the objective of phase 1 was to examine the response of the flotation system with the use of tannin coagulant in the treatment of Monjolinho WWTP UASB effluent (Phase 1A) and also determine the two most suitable dosages of tannin coagulant for the treatment of wastewater from the Monjolinho WWTP UASB tested for each polymer (phase 1B). Phases 1A and 1B were performed with wastewater collected at 8:00 h and 14:00 h, respectively. The objective of phase 2 was to find the optimum dosage of tannin within a narrower range of values, as well as verification of the optimal type and dosage of synthetic polymer (non-ionic, anionic and cationic) to be associated with the tannin coagulant. In phase 1A, it was found that flotation was effective for apparent color removal even to zero coagulant dosage tannin. As for turbidity, there is a marked effect when increasing the coagulant dose, which increased the removal efficiency of this parameter. After obtaining the results of Phase 1B, were chosen for phase 2 two low coagulant dosages which can promote reduction of turbidity by 85%. Besides the two dosages obtained in phase 1B, in phase 2 were evaluated other three between them. Thus, in phase 2 were studied coagulant doses of 65, 75, 85, 95 and 105 mg/L, each one associated with six doses of each one of the studied polymers. Among the treatments employed, it could be seen that the non-ionic polymer and the cationic polymer were the most efficient for treatment by coagulation associated with tannin in flotation. The set of tannin coagulant dosage and polymer which showed satisfactory removal of parameters was 65 mg/L of Tannin with 2.0 mg/L of cationic polymer, reaching 95.2% removal of turbidity, 83% of color apparent, 49.2% of total phosphorus, COD 80.7% and 87.9% of TSS under the conditions found at the time of testing, for post-treatment of Monjolinho WWTP UASB effluent by flotation.
32

Avaliação da remoção de Giardia spp. e Cryptosporidium spp. em processos de tratamento de esgoto sanitário / Assessment of removal of Giardia spp. and Cryptosporidium spp. from wastewater treatment processes

Raphael Corrêa Medeiros 27 September 2013 (has links)
Este trabalho teve o intuito de avaliar a eficiência de remoção de protozoários patogênicos - Giardia spp. e Cryptosporidium spp. - em processos de tratamento de esgoto sanitário por reator UASB, lodos ativados, filtro lento em areia e diferentes desinfetantes. A recuperação de cistos de Giardia e de oocistos de Cryptosporidium, realizada por diferentes metodologias e utilizando ColorSeed®, foi de, respectivamente, 85 e 20% em esgoto bruto, e 62,5 e 17,5% em efluente tratado, quando foi utilizado o método de tripla centrifugação. Cistos de Giardia foram encontrados em 100% as amostras de esgoto pesquisadas, com média de 1,5 x 104 cistos por litro e oocistos de Cryptosporidium em 31,4% com média 3,1 x 10² oocistos por litro, em esgoto bruto. No tratamento biológico por reator UASB seguido de Lodos Ativados, a remoção de cisto de Giardia e esporos de Clostridium perfringens foram estatisticamente menores que as remoções de E. coli e coliformes totais. Não foram encontrados (oo)cistos após o tratamento terciário realizado através da filtração lenta em areia. Houve remoção estatisticamente maior na ETE em escala plena para coliformes totais e Clostridium perfringens. E. coli e cistos de Giardia, em ambas ETEs, apresentaram remoções similares. Elevadas concentrações de (oo)cistos foram encontradas no lodo de esgoto, com grande porcentagem ainda viável. Com relação à desinfecção, entre as bactérias indicadoras, Clostridium perfringens foram mais resistentes ao cloro, ozônio e radiação ultravioleta. O efeito sinérgico, promovido pelas desinfecções sequenciais (clororadiação ultravioleta e ozônio-radiação ultravioleta), foi evidenciado em alguns experimentos para todas as bactérias estudadas. O cloro alterou a fluorescência dos cistos de Giardia e o ozônio, além de alterar a fluorescência, foi capaz de diminuir a concentração de cistos desse microrganismo. Pode-se concluir que as concentrações tanto de microrganismos indicadores como de protozoários patogênicos é bastante elevada, qualquer que seja o tipo de esgoto: bruto, efluente do reator UASB ou efluente do lodos ativados. Isso evidencia o extremo cuidado com que estes efluentes devem ser tratados, para posteriores usos ou lançamento em corpo receptor, em especial devido à presença de (oo)cistos ainda viáveis de Giardia spp. e Cryptosporidium spp. mesmo após o tratamento biológico por lodos ativados, e a necessidade de desinfecção do efluente. / This work aimed to evaluate the efficiency of removal of pathogenic protozoa - Giardia spp. and Cryptosporidium spp. - during wastewater treatment by UASB reactor, activated sludge, slow sand filter and different disinfectants. The recovery of Giardia cysts and of Cryptosporidium oocysts, performed by different methodologies and using ColorSeed®, was respectively of 85 and 20%, in raw wastewater and 62.5 and 17.5% in treated effluent, applying triple centrifugation method. Giardia cysts were found in 100% of the the sewage samples surveyed, with average of 1.5 x 104 cysts per liter and Cryptosporidium oocysts were found in 31.4% with average of 3.1 x 10² oocysts per liter, in raw wastewater. Giardia cyst and Clostridium perfringens spores removals were statistically lower than E. coli and total coliforms removal when applying the biological treatment by UASB reactor followed by Activated Sludge. There were no (oo) cysts after treatment tertiary accomplished by slow sand filtration. There was a statistically higher removal in the full scale WWTP for total coliforms and Clostridium perfringens; however, E. coli and Giardia cysts, in both WWTPs, presented the same removal efficiency. High concentrations of (oo)cysts were found in the sludge sludge, with a high percentage still viable. Regarding disinfection, among the indicating bacteria, Clostridium perfringens was more resistant to chlorine, ozone and ultraviolet radiation. The synergic effect promoted by sequential disinfections (chlorine-ultraviolet radiation and ozone-ultraviolet radiation) was evidenced in some experiments for all the bacteria studied. Chlorine altered the fluorescence of Giardia cysts and ozone, as well as change in fluorescence was able to decrease the concentration of this microorganism. It can be concluded that the concentrations of indicator microorganisms as well as of pathogenic protozoa is very high, regardless the kind of wastewater: raw, UASB reactor effluent or activated sludge effluent. This shows the extreme care that must be taken towards these effluents, for future reuse or simply release in the environment, mainly due to the presence of viable Giardia spp. and Cryptosporidium spp. (oo)cysts even after the activated sludge treatment, and the need of disinfection of the effluent.
33

Remoção de nutrientes do efluente de reator anaeróbio utilizando reatores microaeróbio e com aeração intermitente seguidos de flotação por ar dissolvido / Nutrient removal of anaerobic effluent reactor using microaerobic and intermittent aeration reactors followed by DAF

Marchetto, Margarida 07 December 2001 (has links)
O principal objetivo deste trabalho consistiu em avaliar o desempenho de um sistema experimental para pós-tratamento de reatores anaeróbios. Foram testados reator microaerado e reator com aeração intermitente, seguidos de flotação por ar dissolvido. Foram avaliadas condições para se obter nitrificação, desnitrificação e remoção de fósforo, em reator com baixa concentração de OD e em reator em que se alternaram fases aeróbia e anaeróbia. O trabalho foi desenvolvido em duas etapas distintas: a Etapa I constituiu de ensaios preliminares, utilizando instalação em escala de laboratório, alimentados com efluente de reator anaeróbio compartimentado, composta de sistema de aeração com quatro reatores em paralelo, com capacidade de 11,5 L cada, operando em regime hidráulico contínuo, com concentrações de OD na faixa de 0,2 a 0,9 mg/L, em temperatura controlada de 30±2°C. Na Etapa I também foram operados reatores com aeração intermitente. Na Etapa II, empregou-se instalação para tratamento aeróbio, com capacidade de 100 L, seguida de flotador, em temperatura ambiente de 25±6°C, sendo operado um reator microaerado e outro com aeração intermitente; ambos foram alimentados com efluente de um reator anaeróbio de leito expandido. O sistema com aeração intermitente (&#952h: 6 h) mostrou-se estável, apresentando elevada remoção média de DQO (92%), de P-PO4-3 (90%) e de nitrogênio (sem utilização de fonte externa de carbono; apenas com recirculação adequada do lodo). Para &#952h médio de 8 h, nos ensaios com ciclos alternados de 2 h, com aeração e 4 h, sem aeração, foi obtida remoção máxima de P-PO4-3, de 95% para as amostras brutas e 97% para as amostras filtradas, com remoção média de 84%, e 88%, respectivamente. Considerando apenas os valores médios, registrou-se ligeira queda de remoção de P-PO4-3, e de DQO em relação ao período com &#952h médio de 6 h. Os resultados com aeração intermitente foram sensivelmente melhores em relação aos obtidos com microaeração. / The aim of this research the performance evaluation of a pilot system for post treatment of anaerobic reactors. Microaeration and intermittent aeration reactors, followed by dissolved air flotation (DAF) were examined. It was assessed the conditions to obtain nitrification, denitrification and phosphorus removal, in reactor operated with low concentration of OD and in a reactor operated were alternated aerobic and anaerobic phases were used. The research was developed in two different stages. The first one, constituted of preliminary test, using installation in laboratory scale, fed with effiuent of compartment anaerobic reactor. This system was composed of aeration system with four reactors in parallel, with 11,5 L each, operating in continuous flow, with concentrations of DO between 0.2 to 0.9 mg/L, in controlled temperature of 30±2 ºC. The reactors were also operated with intermittent aeration. In the second stage, an installation with 100L was used for aerobic treatment, followed by DAF, in room temperature of 25±6°C. One reactor was operated under microaeration and another with intermittent aeration. Both were fed with effiuent of an expanded bed anaerobic reactor. The system with intermittent aeration (&#952h: 6 h) shown stable, presenting high COD removal of (92%) and phosphorus removal (90%), without use of external carbon source; just with adapted recirculation of the sludge. For an average hydraulic retention time of 8 h, in the test with alternate cycles of 2 h with aeration and 4 h without aeration, it was obtained a maximum removal of P-PO4-3 equal 95% for the raw samples and 97% for the filtered samples, with average removal of 84%, and 88%, respectively. The results with intermittent aeration were significantely better in relation to the obtained with microaeration.
34

Remoção de nutrientes do efluente de reator anaeróbio utilizando reatores microaeróbio e com aeração intermitente seguidos de flotação por ar dissolvido / Nutrient removal of anaerobic effluent reactor using microaerobic and intermittent aeration reactors followed by DAF

Margarida Marchetto 07 December 2001 (has links)
O principal objetivo deste trabalho consistiu em avaliar o desempenho de um sistema experimental para pós-tratamento de reatores anaeróbios. Foram testados reator microaerado e reator com aeração intermitente, seguidos de flotação por ar dissolvido. Foram avaliadas condições para se obter nitrificação, desnitrificação e remoção de fósforo, em reator com baixa concentração de OD e em reator em que se alternaram fases aeróbia e anaeróbia. O trabalho foi desenvolvido em duas etapas distintas: a Etapa I constituiu de ensaios preliminares, utilizando instalação em escala de laboratório, alimentados com efluente de reator anaeróbio compartimentado, composta de sistema de aeração com quatro reatores em paralelo, com capacidade de 11,5 L cada, operando em regime hidráulico contínuo, com concentrações de OD na faixa de 0,2 a 0,9 mg/L, em temperatura controlada de 30±2°C. Na Etapa I também foram operados reatores com aeração intermitente. Na Etapa II, empregou-se instalação para tratamento aeróbio, com capacidade de 100 L, seguida de flotador, em temperatura ambiente de 25±6°C, sendo operado um reator microaerado e outro com aeração intermitente; ambos foram alimentados com efluente de um reator anaeróbio de leito expandido. O sistema com aeração intermitente (&#952h: 6 h) mostrou-se estável, apresentando elevada remoção média de DQO (92%), de P-PO4-3 (90%) e de nitrogênio (sem utilização de fonte externa de carbono; apenas com recirculação adequada do lodo). Para &#952h médio de 8 h, nos ensaios com ciclos alternados de 2 h, com aeração e 4 h, sem aeração, foi obtida remoção máxima de P-PO4-3, de 95% para as amostras brutas e 97% para as amostras filtradas, com remoção média de 84%, e 88%, respectivamente. Considerando apenas os valores médios, registrou-se ligeira queda de remoção de P-PO4-3, e de DQO em relação ao período com &#952h médio de 6 h. Os resultados com aeração intermitente foram sensivelmente melhores em relação aos obtidos com microaeração. / The aim of this research the performance evaluation of a pilot system for post treatment of anaerobic reactors. Microaeration and intermittent aeration reactors, followed by dissolved air flotation (DAF) were examined. It was assessed the conditions to obtain nitrification, denitrification and phosphorus removal, in reactor operated with low concentration of OD and in a reactor operated were alternated aerobic and anaerobic phases were used. The research was developed in two different stages. The first one, constituted of preliminary test, using installation in laboratory scale, fed with effiuent of compartment anaerobic reactor. This system was composed of aeration system with four reactors in parallel, with 11,5 L each, operating in continuous flow, with concentrations of DO between 0.2 to 0.9 mg/L, in controlled temperature of 30±2 ºC. The reactors were also operated with intermittent aeration. In the second stage, an installation with 100L was used for aerobic treatment, followed by DAF, in room temperature of 25±6°C. One reactor was operated under microaeration and another with intermittent aeration. Both were fed with effiuent of an expanded bed anaerobic reactor. The system with intermittent aeration (&#952h: 6 h) shown stable, presenting high COD removal of (92%) and phosphorus removal (90%), without use of external carbon source; just with adapted recirculation of the sludge. For an average hydraulic retention time of 8 h, in the test with alternate cycles of 2 h with aeration and 4 h without aeration, it was obtained a maximum removal of P-PO4-3 equal 95% for the raw samples and 97% for the filtered samples, with average removal of 84%, and 88%, respectively. The results with intermittent aeration were significantely better in relation to the obtained with microaeration.
35

Emprego de coagulante à base de tanino em sistema de pós-tratamento de efluente de reator UASB por flotação / Use of tannin-based coagulant in exhaust post-treatment of UASB reactor effluent by flotation

Eloá Cristina Figueirinha Pelegrino 03 June 2011 (has links)
O presente trabalho teve como objetivo principal a avaliação da eficiência de remoção de carga orgânica, fósforo e sólidos em suspensão de sistema de flotação tratando esgoto sanitário pré-tratado em reatores UASB, da ETE Monjolinho da cidade de São Carlos/SP, e coagulado com tanino associado ou não a polímeros sintéticos. Os ensaios com variação de dosagem de coagulante Tanino e polímeros (polímero catiônico, polímero não-iônico e polímero aniônico) foram realizados em escala de laboratório, com o uso do equipamento flotateste. Em todos os ensaios foram fixados os valores de gradiente de velocidade na mistura rápida (800/s) e na floculação (90/s), ao tempos de detenção na mistura rápida (20 s) e na floculação (15 min) e, a pressão de saturação 5 Bar e a razão de recirculação (17%). Durante os ensaios com unidade de flotação em escala de bancada foram avaliados três valores de velocidades de flotação: 12,0 cm/min, 16,0 cm/min e 20,0 cm/min. Os ensaios foram divididos em duas fases: a fase 1 teve como objetivo analisar a resposta do sistema de flotação com o emprego do coagulante Tanino no tratamento do efluente do reator UASB da ETE Monjolinho (fase 1A) e também determinar as duas dosagens do coagulante Tanino mais adequadas para o tratamento do efluente de UASB da ETE Monjolinho para cada polímero testado (fase 1B). As fases 1A e 1B foram realizadas com efluente coletado às 8:00 h e 14:00 h, respectivamente. A fase 2 teve como objetivo a busca da dosagem ótima de tanino dentro de uma faixa mais estreita de valores, assim como a verificação do melhor tipo e dosagem de polímero sintético (não-iônico, aniônico e catiônico) para ser associado ao coagulante tanino. Na fase 1A, verificou-se que a flotação foi efetiva para remoção de cor aparente mesmo para dosagem nula de coagulante Tanino. Quanto à turbidez, verificou-se efeito marcante da adição de dosagem crescente de coagulante no aumento da eficiência de remoção desse parâmetro. Após a obtenção dos resultados da fase 1B, foram escolhidas para a fase 2 as duas menores dosagens de coagulante capazes de promover redução da turbidez em pelo menos 85%. Além destas duas dosagens, foram avaliados na fase 2 outras 3 dosagens compreendidas entre elas. Sendo assim, na fase 2 foram estudadas as doses de 65, 75, 85, 95 e 105 mg/L de coagulante, cada qual associada a seis dosagens de cada um dos polímeros estudados. Entre os tratamentos empregados, pôde-se verificar maior eficácia do polímero não-iônico e do polímero catiônico para o tratamento por flotação, associado ao coagulante tanino. O conjunto de dosagem de coagulante tanino e polímero mais vantajoso, ou seja, menor dosagem de tanino que, associada a polímero, apresentou remoção satisfatória dos parâmetros estudados, foi 65 mg/L de Tanino e 2,0 mg/L de polímero catiônico, atingindo remoções de 95,2% de turbidez (Residual de 3,65 NTU), 82,1% de cor aparente (Residual de 98 mgPT/L), 49,2% de fósforo total (Residual de 3,2 mg/L), 80,7% de DQO (Residual de 25 mg/L) e 87,9 % de SST (Residual de 13 mg/L) nas condições encontradas na época dos ensaios, para o pós-tratamento por flotação de efluente de reator UASB da ETE Monjolinho, São Carlos/SP. / The main objective of this work is the evaluation of the efficiency of removal of organic load, phosphorus and suspended solids in the flotation system treating domestic wastewater pretreated in UASB reactors, of the Monjolinho Wastewater Treatment Plant (WWTP) of Sao Carlos, SP and clotted with tannin alone or combined with synthetic polymers. Tests varying tannin dosage of coagulant and polymer (cationic polymer, nonionic polymer and anionic polymer) were performed on a batch scale, using flotatest. In all the tests were fixed the values of rapid mix (800/s) and flocculation (90/s) velocity gradients, the rapid mix (20 s) and flocculation (15 min) times, saturation pressure (5 Bar) and recycle rate (17%). During the test in the flotation bench scale unity three values of flotation velocities were evaluated: 12.0 cm/min, 16.0 cm/min and 20.0 cm/min. The tests were divided in two phases: the objective of phase 1 was to examine the response of the flotation system with the use of tannin coagulant in the treatment of Monjolinho WWTP UASB effluent (Phase 1A) and also determine the two most suitable dosages of tannin coagulant for the treatment of wastewater from the Monjolinho WWTP UASB tested for each polymer (phase 1B). Phases 1A and 1B were performed with wastewater collected at 8:00 h and 14:00 h, respectively. The objective of phase 2 was to find the optimum dosage of tannin within a narrower range of values, as well as verification of the optimal type and dosage of synthetic polymer (non-ionic, anionic and cationic) to be associated with the tannin coagulant. In phase 1A, it was found that flotation was effective for apparent color removal even to zero coagulant dosage tannin. As for turbidity, there is a marked effect when increasing the coagulant dose, which increased the removal efficiency of this parameter. After obtaining the results of Phase 1B, were chosen for phase 2 two low coagulant dosages which can promote reduction of turbidity by 85%. Besides the two dosages obtained in phase 1B, in phase 2 were evaluated other three between them. Thus, in phase 2 were studied coagulant doses of 65, 75, 85, 95 and 105 mg/L, each one associated with six doses of each one of the studied polymers. Among the treatments employed, it could be seen that the non-ionic polymer and the cationic polymer were the most efficient for treatment by coagulation associated with tannin in flotation. The set of tannin coagulant dosage and polymer which showed satisfactory removal of parameters was 65 mg/L of Tannin with 2.0 mg/L of cationic polymer, reaching 95.2% removal of turbidity, 83% of color apparent, 49.2% of total phosphorus, COD 80.7% and 87.9% of TSS under the conditions found at the time of testing, for post-treatment of Monjolinho WWTP UASB effluent by flotation.
36

Remoção de DQO e de nitrogênio, e estudo dos consórcios microbianos em sistema com três reatores sobrepostos, em série, alimentado com esgoto sanitário / COD and nitrogen removal, and microbial associations study on a three superposed, in series, reactors system, fed with domestic wastewater

Pedro Ivo de Almeida Santos 17 December 2004 (has links)
Esta pesquisa enfoca a avaliação do desempenho de nova configuração de unidade para tratamento biológico de esgoto sanitário por processo combinado, visando à remoção de nutrientes, especialmente nitrogênio. O sistema construído em escala piloto tem volume útil igual a 71,48 litros. Nesta nova configuração de reatores para tratamento terciário de esgoto sanitário, utilizaram-se três reatores sobrepostos, sendo: um reator UASB - “Upflow Anaerobic Sludge Blanket”; um reator de leito móvel e filme fixo aeróbio (com aplicação de oxigênio puro); e, um reator de leito móvel e filme fixo com ambiente anóxico. O material suporte utilizado nos reatores de leito móvel e filme fixo constituiu alternativa inédita no tratamento de efluentes líquidos. Foram utilizadas cavilhas “ranhuradas” de madeira, de dimensões aproximadas de 8,0 mm de diâmetro por 8,0 mm de comprimento. O desempenho geral do sistema quanto à remoção de matéria carbonácea e compostos nitrogenados, e as associações microbianas formadas nos três reatores são objetos principais de estudo deste trabalho. Foram obtidos resultados de remoção de DQO e de nitrogênio bastante satisfatórios, sobretudo quando o tempo de detenção hidráulica total esteve próximo a 20 horas, incluindo o compartimento de decantação (94,6 % para DQO; e 96,7 % para N-NTK, com formação de nitrato em concentrações inferiores a 10,0 mgN-NO3-/l). O TDH estudado variou entre 5 e 24 horas para os sistema completo. O estudo dos consórcios de microrganismos forneceu excelentes resultados quanto à quantidade, diversidade, e atividade das populações desenvolvidas nos diferentes ambientes, confirmando o bom desempenho do sistema e o fornecimento de ambiente adequado para o desenvolvimento das diferentes populações nos três reatores. A idealização desta configuração tem como finalidade realização de tratamento de esgoto sanitário até nível terciário em planta compacta, podendo ser utilizada por pequenas e grandes comunidades, devido à possibilidade de se construir diversos módulos do sistema proposto. / This research is focused on the performance evaluation of a new system configuration of combined biological reactors, treating domestic wastewater till tertiary level. The pilot scale proposed system had a total useful volume of 71,48 liters. This new configuration involves three types of superposed reactors: an Upflow Anaerobic Sludge Blanket reactor; an aerobic fixed film mobile bed reactor (fed with pure oxygen); and a fixed film mobile bed reactor at anoxic environment. The support material used inside the fixed film mobile bed reactors was wood made grooved dowels. The main purposes of this work are to evaluate the systems general performance regarding COD and nitrogen removal, and the microbial associations inside the reactors. It reached quite satisfactory results regarding COD and nitrogen removal when the total hydraulic retention time (HRT) was around 20 hours, including the clarification zone volume (94,6 % for the COD; and 96,7 % for the TKN-N, whit nitrate formation below 10,0 mgN-NO3-/l). HRTs from 5 to 20 hours were studied. The microbial associations were present in large number, with a great diversity and high specific activities at the different environments, confirming the good results obtained and the suitable environment provided for the growth of the different populations inside the three reactors. The idealization of this treatment system has the goal to treat domestic wastewater from small to large communities till tertiary level, in compact treatment plants, due to the possibility of constructing several modules of the system.

Page generated in 0.098 seconds