• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 11
  • 11
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Structural and functional diversity of epilithic bacterial communities in streams : effects of pollution

Mahmoud, Huda Mahmoud Abdullah January 2002 (has links)
No description available.
2

Endocrine Disrupting Compounds in Victorian Wastewater Treatment Plant Effluents

Cindi Mispagel Unknown Date (has links)
The project involved the study of 12 Victorian municipal wastewater treatment plant discharges. These included lagoon-based plants and those with activated sludge based processes. Permission was obtained from all the relevant water authorities to collect samples of final effluent at point of discharge to the environment, whether that was to a creek, a river, the ocean, or the land. Samples were collected in November 2003, and then again in April and June 2004, and subjected to a number of biological and chemical analyses, including toxicity tests, measurement of hormonal (estrogenic) activity using yeast-based bioassays, and the measurement of specific hormonal concentrations (17-estradiol) using enzyme-linked immunosorbent assays (ELISA). Almost all of the effluents examined showed estrogenic activity, to a greater or lesser extent (no response to 55 ng/L 17β-estradiol equivalents). On the whole, the levels of estrogenic activity observed were to the lower end of the range observed overseas in the northern hemisphere, and comparable with that recently reported in Australia and New Zealand using similar, human-estrogen receptor based assays (no response to ~ 10 ng/L 17β-estradiol equivalents). The reassuring low/no assay response is bolstered by the chemical assessment of estradiol concentrations by ELISA, which returned concentrations of these compounds for the most part in the range 2-5 ng/L. From an aquatic environmental perspective, it is difficult to say with any certainty what the potential risk to aquatic organisms in waters receiving these effluents will be. Typically, in environmental risk assessment one first looks to agreed national or international guideline or trigger values for the type of waters being assessed. In this case, there are as yet no guideline values. Without guideline values to drive the assessment, then one compares a chemical’s concentration in a sample (in this case a WWTP effluent) with data obtained from toxicological experiments in which the concentration known to elicit a specific effect has been determined. In this case, levels of 17β-estradiol were typically between the lowest reported level to induce the production of Female-indicative proteins in male fish (plasma vitellogen; 1 ng/L), and the lowest concentration of known to induce intersex in fish (8 ng/L). Consequently, such levels in a WWTP discharge are likely to be an environmental risk if there is little or no dilution of the discharge by the receiving water, i.e. discharge represents major component of stream flow. In short, to truly assess the risk (hormonal impact) of these WWTP effluents, in vivo testing needs to be undertaken, ideally with a representative native species but failing that with a ‘standard’ species such as the fathead minnow. When this programme began, the ‘watching brief’, being held in Australia on the topic of endocrine disrupting chemicals and their potential effects on aquatic wildlife was considered too passive by many. It still is, by some. Despite the assurance the results may provide (of minimal impact in most cases if there is significant dilution), there is still a need for further extensive on-ground, reassurance research to provide data for higher-level risk assessment by industry and government agencies.
3

Degradação simultânea de bisfenol A e carbamazepina em efluente de estação de tratamento de esgoto por processo foto-Fenton / Simultaneous degradation of bisphenol A and carbamazepine in effluent from sewage treatment plant using photo-Fenton process

Alamino, Andreza de França [UNESP] 19 August 2016 (has links)
Submitted by Andreza de França Alamino null (andreza.alamino@hotmail.com) on 2016-09-10T18:02:45Z No. of bitstreams: 1 dissertacao_versão_final_pdf_repositório_unesp.pdf: 1884907 bytes, checksum: 6161a04cdaac1c53204da25be3831d76 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2016-09-13T14:20:36Z (GMT) No. of bitstreams: 1 alamino_af_me_araiq.pdf: 1884907 bytes, checksum: 6161a04cdaac1c53204da25be3831d76 (MD5) / Made available in DSpace on 2016-09-13T14:20:36Z (GMT). No. of bitstreams: 1 alamino_af_me_araiq.pdf: 1884907 bytes, checksum: 6161a04cdaac1c53204da25be3831d76 (MD5) Previous issue date: 2016-08-19 / O presente trabalho aborda a degradação simultânea de dois contaminantes emergentes, o plastificante bisfenol A (BPA) e o fármaco carbamazepina (CBZ), aplicando-se processos oxidativos avançados (POA), particularmente o processo foto-Fenton. Durante os ensaios de degradação, o BPA e a CBZ foram determinados por cromatografia líquida de alta eficiência (CLAE) em uma única análise, utilizando dois detectores acoplados em série, o detector de fluorescência (FLU) para o BPA e detector de arranjo de diodos (DAD) para a CBZ. Foi necessária a otimização das condições do método cromatográfico, tais como, composição da fase móvel, 50% etanol-água, vazão, 0,500 mL min-1, comprimento de onda de excitação e emissão para o BPA, 277 e 300 nm nesta ordem, e absorção para a CBZ de 286 nm ou 211 nm. Após a construção da curva analítica foram determinados os parâmetros analíticos como: linearidade, limites de detecção e quantificação. Os ensaios de degradação foram efetuados em duas matrizes distintas, água e efluente de estação de tratamento de esgoto, coletado antes do lançamento nos rios, objetivando desenvolver um método de degradação em baixas concentrações em amostras reais. Pela complexidade da matriz foi necessário fazer o “clean up” das amostras por extração em fase sólida (EFS) nas alíquotas retiradas durante as degradações no efluente. A faixa de recuperação da EFS foi avaliada em três níveis e atingiu de 82 a 84% para o BPA e de 92 a 99% para a CBZ. A velocidade de degradação tanto de BPA como de CBZ foi influenciada pela matriz, pois foi maior em água do que no efluente. O tempo de degradação em água foi de 60 minutos e em efluente de 90 minutos. A degradação de BPA atingiu 88% em água e 77% em efluente, enquanto que de CBZ atingiu 95% em água e 61% em efluente. A remoção de carbono orgânico dissolvido (COD) nas amostras de efluente foi avaliada, porém as concentrações de Fe(III) e H2O2 utilizadas, 12,0 μmol L-1 e 300 μmol L-1 nesta ordem, não foram suficientes para degradar a matéria orgânica do efluente, mas foram suficientes para a degradação dos compostos alvos na concentração de 250 μg L-1.
4

Técnica de eletroflotação aplicada na remoção de cores de efluentes têxteis / Electroflotation technique applied in color removal from textile effluents

Camboim, Ricardo Augusto 16 August 2018 (has links)
Orientador: João Sinézio de Carvalho Campos / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-16T15:17:01Z (GMT). No. of bitstreams: 1 Camboim_RicardoAugusto_M.pdf: 5018034 bytes, checksum: aeb7e981adfca5bcafba7911a3f453c0 (MD5) Previous issue date: 2010 / Resumo: Com o aumento da preocupação do homem com o meio ambiente, as indústrias passaram a se preocupar mais com o descarte de seus efluentes, com isso, vem sendo desenvolvidas técnicas para tratamento de efluentes. No presente trabalho utiliza-se a técnica de eletroflotação, para o tratamento de efluente de tinturaria de tecidos, a qual utiliza corantes reativos. Para tal montou-se um reator composto por: Uma cuba com capacidade para 50 litros, uma fonte de tensão com potencia ajustável e eletrodos metálicos com geometria retangular com área efetiva de 216 cm2. Os parâmetros estudados compreendem o tipo de material utilizado como eletrodo (ferro, aço inox e alumínio), o pH, temperatura e turbidez. Também foi feito a análise espectrofotométrica para avaliar a remoção de cor, também fizemos analise de DBO, DQO, Turbidez e Sólidos Totais no inicio e no final do tratamento. De acordo com os resultados observa-se uma drástica redução da turbidez, um leve aumento do pH (cerca de 10% do valor inicial) e aumento da temperatura (tipicamente 10%) no final do tratamento. Cabe ressaltar que neste processo de eletroflotação não se utiliza nenhum produto químico, somente energia elétrica. Assim tal processo torna-se bastante interessante devido à alta eficiência na remoção total da coloração do efluente em pouco tempo de tratamento em comparação com tratamentos convencionais. Ainda mais, pela análise visual do sobrenadante, verifica-se adicionalmente uma significativa remoção de material orgânico, tornando-o atrativo do ponto de vista ambiental / Abstract: With the increase of man's concern with the environment, industries began to worry more about the disposal of their waste, thereby, have been developed techniques for effluents treatment. The present work uses the technique of electroflotation for the treatment of effluents from dyeing of fabrics, which uses reactive dyes. In order to do this, a reactor was set up being composed by a tank with a capacity of 50 liters, a source of tension with adjustable power and metal electrodes with rectangular geometry with effective area of 216 cm2. The parameters studied include the type of material used as electrode (iron, steel and aluminum), pH, temperature and turbidity was also made a spectrophotometric analysis to evaluate the removal of color, we also examine the BOD, COD, Turbidity and Total Solids from the beginning and from the end of treatment. According to the results there is a drastic reduction in turbidity, a slight increase in pH (about 10% over baseline) and increased temperature (typically 10%) at the end of treatment. It is noteworthy that this electroflotation process do not use any chemicals, only electric power. So this process becomes quite interesting because of the high efficiency in removal of the color of the effluent in a short time of treatment compared with conventional treatments. Moreover, from the visual analysis of the supernatant, there is additionally a significant removal of organic material, making it attractive from an environmental standpoint / Mestrado / Ciencia e Tecnologia de Materiais / Mestre em Engenharia Química
5

Avaliação de um sistema piloto para tratamento de efluentes de sala de ordenha de bovinocultura / Evaluation of a pilot system treating milking parlor effluent

Silva, Edu Max da, 1954- 30 July 2007 (has links)
Orientador: Denis Miguel Roston / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-09T13:06:32Z (GMT). No. of bitstreams: 1 Silva_EduMaxda_M.pdf: 12592705 bytes, checksum: fa560f6bfbe78ace9e89fc4061f0170c (MD5) Previous issue date: 2007 / Resumo: Uma das maiores dificuldades no gerenciamento do confinamento de gado leiteiro é a grande quantidade de dejetos produzidos diariamente numa área reduzida, que pode ser uma ótima opção de fertilizantes ou um enorme potencial poluente, dependendo de como é feita a disposição destes dejetos, um dos principais desafios para criadores e especialistas. No Brasil, o destino dos efluentes brutos dos confinamentos de vacas leiteiras, foi e continua sendo os cursos d¿água usando o ultrapassado método da diluição, como única forma para eliminar os resíduos das instalações e com isso podendo provocar a eutrofização de rios, riachos, lagos e lagoas. Foi implantado um projeto piloto, no Sítio Nossa Senhora da Conceição, com as condições tanto opográficas como climáticas idênticas, para tratar 10% de um efluente similar ao produzido na UEP de bovinocultura leite da EAFI/MG. A ETE piloto era composta por três unidades, sendo uma lagoa anaeróbia, uma lagoa facultativa e um pós-tratamento utilizando um leito cultivado (¿constructed wetland¿). A lagoa anaeróbia não suportou o lançamento do efluente bruto lançado na ETE piloto para tratamento de águas residuárias oriundas da sala de ordenha da bovinocultura leite. Para reduzir a quantidade de sólidos flutuantes na lagoa anaeróbia, a recomendação apresentada foi a construção de um tanque tipo séptico capaz de reter os sólidos flotantes. O leito cultivado foi a unidade da ETE piloto que não aparentou mudanças externas. A ETE piloto registrou uma remoção média dos parâmetros analisados em torno de: fósforo na forma de (P) e (PO4) 80%; amônia (NH3-N) e nitrato (NO3) 88%; DQO 89%, pH médio das amostras analisadas em 6,23; sólidos (ST) e (STV) 67%; turbidez 60%. Em se tratando de resíduos líquidos da produção animal, pode-se afirmar que o resultado é positivo, demonstrando que está opção de sistema de tratamento tem grande potencial de aplicação / Abstract: One of the major concerns in dairy cattle lodging management is the great amount of manureproduced daily in a reduced area, that can be an excellent fertilizer option or an enormous pollutant potential, depending on the disposal procedures. In Brazil, the destination of raw effluent of lodged dairy cattle was in the past and continues nowadays being the water courses using the conventional and condemned method of the dilution, as only form to eliminate the residues of the installations which is one of the reasons for eutrophication of rivers, streams, lakes and ponds. A pilot plant was installed to treat 10% of the effluent produced in the dairy parlor installations of the EAFI/MG. The pilot plant was designed with three units: an anaerobic lagoon followed by a facultative pond and a subsurface constructed wetland. The pilot plant presented the following average removal: phosphorus, 80%; nitrate, 88%; COD, 89%; total solids, 67%; and turbidity, 60%. The pH during the whole operation maintained around the value of 6,2. The study conclued that the system presented a great potential for treatment of dairy parlor effluent / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
6

Sistemas naturais para tratamento de resíduos líquidos de bovinocultura de leite / Natural systems for treating liquid waste from dairy production

Silva, Edu Max da, 1954- 24 August 2018 (has links)
Orientador: Denis Miguel Roston / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-24T11:06:36Z (GMT). No. of bitstreams: 1 Silva_EduMaxda_D.pdf: 5550802 bytes, checksum: 9ab6a662fd86349f1faa976169d785c5 (MD5) Previous issue date: 2013 / Resumo: A pecuária moderna enfrenta grandes desafios para estabelecer o equilíbrio das estreitas relações entre: produção intensiva, saúde animal e sustentabilidade ambiental. Contudo, ainda existe uma grande lacuna entre a produtividade animal e o meio ambiente.Os prejuízos ambientais podem tornar-se ainda maiores quando esses resíduos orgânicos são arrastados ou lançados diretamente nos cursos d¿água, fato que pode reduzir de forma drástica os teores de oxigênio dos corpos hídricos receptores e provocar a eutrofização de rios, riachos, lagos e lagoas. Os dejetos também podem causar contaminação do solo, do ar e se dispostos ao lado das instalações, podem contribuir para a proliferação de moscas, roedores e tornarem-se repugnantes, devido ao aspecto e odor. Neste trabalho avaliou-se, de Julho/2012 a Agosto/2013, a eficiência do tratamento dos efluentes líquidos da Unidade Educativa de produção (UEP) - animais de grande porte - bovinocultura de leite do IFSULDEMINAS - Campus Inconfidentes. O sistema de tratamento era composto de unidades de retenção de sólidos, reator anaeróbio compartimentado e "wetland" construído. As eficiências de redução dos parâmetros analisados foram: Sólidos Totais (ST) - 95 %, Sólidos Dissolvidos Totais (SDT) - 95%, Sólidos Sedimentáveis (SSed.) - 100%, Demanda Química de Oxigênio (DQO) - 99%, Demanda Bioquímica de Oxigênio (DBO) - 97%, Nitrogênio Amoniacal - 93%, Nitrato (NO3-) - 88%, Nitrogênio Total Kjeldahl (NTK) - 96% e Fósforo (P) - 93%. A partir dos resultados obtidos, pode-se recomendar o sistema proposto como alternativa tecnológica para tratamento de resíduos líquidos de instalações e equipamentos de bovinocultura de leite / Abstract: The modern dairy production faces big challenges to balancing the close relations between intensive production, animal health and environmental sustainability. The increase in the number of concentrated animal feeding operations, mainly dairy production, may increase proportionally the amount of waste produced, which can impact severely the environment especially when there are no treatment systems for those organic wastes. Environmental damage may become even greater when the organic wastes are dragged directly into waterways, which greatly reduces the levels of oxygen causing eutrophication of rivers, streams, lakes and ponds. The waste can also cause contamination of soil, air and disposed adjacent to the premises, may contribute to the proliferation of flies, rodents and become loathsome because of appearance and unpleasant odor. This work proposed a treatment plant to treat waste from dairy production composed by retention solids units, anaerobic baffled reactor and constructed wetland. The system was evaluated from July/ 2012 to August/2013. The results obtained regarding system efficiency in removal/reduced the analyzed parameters were: Total Solids (TS) - 95%, Total Dissolved Solids - 95%, Settling Solids - 100%, Chemical Oxygen Demand (COD) - 99%, Biochemical Oxygen Demand (BOD) - 97%, Ammonia Nitrogen - 93%, Nitrate - 88%, Total Kjeldahl Nitrogen (TKN) - 96% and Phosphorus (P) - 93%. According to the results, the system proposed may be considered as a technological alternative to treat liquid waste from facilities and equipments from dairy production / Doutorado / Agua e Solo / Doutor em Engenharia Agrícola
7

Emprego de biofiltro de pedra para remo??o de microalgas e s?lidos suspensos de efluentes de lagoas de estabiliza??o

Queiroz, Mois?s Andrade de Farias 28 February 2014 (has links)
Made available in DSpace on 2014-12-17T15:03:33Z (GMT). No. of bitstreams: 1 MoisesAFQ_DISSERT.pdf: 1322817 bytes, checksum: d69733a37de991cb265f0cf0939bee27 (MD5) Previous issue date: 2014-02-28 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds / A pesquisa avaliou a remo??o das microalgas produzidas em um sistema de lagoas de estabiliza??o utilizando biofiltros como p?s-tratamento, al?m de caracterizar os efluentes de lagoas de estabiliza??o e dos filtros no tocante ?s concentra??es de biomassa algal (clorofila a e s?lidos suspensos), mat?ria org?nica (DBO e DQO), ortofosfato, f?sforo total, pH e oxig?nio dissolvido, e buscou correlacionar os par?metros f?sico-qu?micos com a clorofila a . Foi realizada na ETE Ponta Negra que ? constitu?da por tr?s lagoas de estabiliza??o, sendo uma lagoa facultativa prim?ria e duas de matura??o. Para a remo??o das algas, foram utilizados dois biofiltros submersos: o filtro FLF -alimentado com efluente da lagoa facultativa; e o filtro FLM - alimentado com efluente da segunda lagoa de matura??o. O material de enchimento de ambos os filtros foi predominantemente brita n? 2, apesar de conter por??es de brita n? 1 e n? 3. As condi??es operacionais dos filtros eram p?ssimas, pois estavam h? quase 10 anos sem manuten??o, sem limpeza ou remo??o do lodo desde a ?poca da constru??o, podendo parte do material de enchimento estar colmatado. Apesar das condi??es operacionais prec?rias foram obtidos resultados satisfat?rios, em n?vel de p?s-tratamento. As efici?ncias de remo??o em rela??o ? DBO e DQO foram de 7 e 25% no FLF e 9 e 19% no FLM, respectivamente. Em rela??o aos SST as efici?ncias no FLF e FLM foram de 37 e 20%, respectivamente. Quanto ? remo??o de clorofila a , a efici?ncia no FLF foi de 44% e no FLM foi de 40%. Houve o consumo de 50% do oxig?nio dissolvido, em m?dia, no interior dos filtros. Foram realizados dois perfis nos filtros, e foi poss?vel concluir que as varia??es ao longo do dia n?o foram estatisticamente significativas, e que, independentemente do hor?rio da coleta, teriam a mesma representatividade ao comparar com o hor?rio da coleta da pesquisa (7 horas da manh?) e a m?dia di?ria, embora as varia??es pontuais ao longo do dia tenham se mostrado expressivas. Outra importante observa??o foi que as correla??es entre Clorofila a e SST foram maiores e mais significativas nos efluentes dos filtros do que nos efluentes das lagoas
8

Aplicação do processo Fenton-like em sistema batelada e em fluxo contínuo na degradação de efluente têxtil / Application process Fenton-like system in batch and continuous flow in degradation of textile effluent

Martins, Thyara Campos 14 February 2013 (has links)
Made available in DSpace on 2017-07-10T18:08:00Z (GMT). No. of bitstreams: 1 Thyara Campos Martins.pdf: 1837547 bytes, checksum: 733e952ccfb67393e6688fdf9fec96e7 (MD5) Previous issue date: 2013-02-14 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / The objective of this study is to evaluate the performance of Fenton-like process using steel wool trade as a source of metallic iron and ferrous ions in the treatment of textile effluent. Preliminary experiments were conducted to evaluate the efficiency of the Fenton-like degradation and mineralization of organic and inorganic pollutants. The experiments were conducted in laboratory scale reactors. The operational parameters of the reactor: H2O2 molar concentration of reactants and Fe0 were optimized based on the values of total organic carbon (TOC), chemical oxygen demand (COD), turbidity and discoloration from an experimental design Delineation Central Composite Rotational (DCCR) 22 quadruplicate with the center point and another 4 axial points. Obtained good representation of the experimental data verified by analysis of variance. The efficiency of the processes used in the treatment of textile effluent was evaluated based on the parameters: decreased levels of TOC, COD, color and turbidity, as well as analysis of the behavior of the concentrations of sulfate, nitrate, hydrogen peroxide, dissolved iron, ammonia and organic nitrogen and reduced absorbance in the lengths where 320 and 600 nm. The molar ratio of the highest efficiency for conventional Fenton process was 1:0,9:27,5 to their COT:Fe2+:H2O2. Under these conditions, the process decreased by 91.06% of the TOC parameter, whereas the COD was reduced by 94.51%, 99.02% of discoloration and 99.88% of reduced turbidity. The Fenton-like process showed greater reductions of the parameters studied when subjected to 1:1,7:27,5 molar ratio of the respective TOC:Fe0:H2O2; these conditions the process showed 92.88% reduction of TOC, 93.91% reduction of COD, 98.11% of discoloration and 98.87% reducing turbidity. Both procedures showed these results to a reaction time of 720 minutes. Using the continuous flow system for the FL and FC process, the system allowed an efficient degradation of the effluent at retention times of about 720 minutes. The processes presented similar efficiencies, which demonstrates that the Fenton-like process is an effective alternative for the treatment of textile effluents. Confirming the ability of steel wool as the source of metallic iron, capable of use in oxidation processes of degradation. / O objetivo deste trabalho é avaliar o desempenho do processo Fenton-like, utilizando lã de aço comercial como fonte de ferro metálico e íons ferrosos, no tratamento de efluente têxtil. Foram realizados experimentos preliminares para avaliar a eficiência do processo Fenton-like na mineralização e degradação dos poluentes orgânicos e inorgânicos. Os experimentos foram realizados em reatores de escala laboratorial. Os parâmetros operacionais dos reatores: concentração molar dos reagentes H2O2 e Fe0, foram otimizados baseados nos valores do carbono orgânico total (COT), demanda química de oxigênio (DQO), descoloração e turbidez a partir de um planejamento experimental Delineamento Composto Central Rotacional (DCCR) 22 com quadruplicata no ponto central e mais 4 pontos axiais. Obteve-se boa representação dos dados experimentais verificada pela análise de variância. A eficiência dos processos aplicados no tratamento do efluente têxtil foi avaliada baseada pelos parâmetros: redução dos valores do COT, DQO, cor e turbidez, além da análise do comportamento das concentrações de sulfato, nitrato, peróxido de hidrogênio, ferro dissolvido, nitrogênio orgânico e amoniacal e redução da absorvância nos comprimentos de onde de 320 e 600 nm. A razão molar que apresentou maior eficiência para o processo Fenton Convencional foi de 1:0,9:27,5 respectiva ao COT:Fe2+:H2O2. Nessas condições, o processo apresentou redução de 91,06% do parâmetro COT, enquanto que a DQO apresentou redução de 94,51%, 99,02% de descoloração e 99,88% de redução da turbidez. O processo Fenton-like apresentou maiores reduções dos parâmetros estudados, quando submetido à razão molar de 1:1,7:27,5 respectivo ao COT:Fe0:H2O2; nessas condições o processo apresentou 92,88% de redução do COT, 93,91% de redução de DQO, 98,11% de descoloração e 98,87% de redução de turbidez. Ambos os processos apresentaram estes resultados para um tempo de reação de 720 minutos. Utilizando o sistema de fluxo contínuo para os processos FC e FL, o sistema permitiu uma eficiente degradação do efluente, em tempos de retenção da ordem de 720 minutos. Os processos apresentaram eficiências similares, o que demonstra que o processo Fenton-like é uma alternativa eficiente no tratamento de efluente têxtil. Atestando a capacidade da lã de aço como fonte de ferro metálico, passível de utilização em processos oxidativos de degradação.
9

Avaliação de parâmetros operacionais na cinética de degradação do antibiótico ciprofloxacino pelo processo foto-fenton

Santos, Lucilene Cândida dos 29 August 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this work the degradation of the antibiotic ciprofloxacin CIP (33.1 mg L-1) by photo- Fenton process using artificial radiation was evaluated. First, the effect of different concentrations of Fe 3+ (1.4, 5.6, 11.2 and 16.8 mg L -1) on the kinetics of CIP and dissolved organic carbon DOC (mineralization), as well as the consumption of H2O2 using 510 mg L-1 of H2O2and pH 2.5-2.8 was studied. The CIP concentration was below of the quantitation limit of the equipment - LQ (<0.163 mg L-1) in just 2 minutes, for all concentration of Fe3+ evaluated, it was not possible to verify the effect of this operating parameter for the removal of CIP. Regarding the results of mineralization and consumption of H2O2, the best fit mathematical observed for all the experimental data obtained at different concentrations of Fe3+ evaluated, was first order. Furthermore, it was observed that the concentration of Fe3+ resulted in a proportional increase in the rate of mineralization and consumption of H2O2, being the concentration of 11.2 mg L-1 of Fe3+ chosen for the subsequent experiments. Next, the effect of different concentrations of H2O2 (85, 170, 340, 510 and 680 mg L-1) on kinetics of CIP mineralization and consumption of H2O2 using the best concentration of Fe3+ (11.2 mg L-1), and at pH 2.5-2.8 was evaluated. Similar behavior observed for the different concentrations of Fe3+ was obtained, the best mathematical fit for CIP mineralization and H2O2 consumption was of first order. The rate of CIP mineralization also increased proportionally with H2O2 concentration, but up to a certain amount of H2O2 (340 mg L-1). Above of this concentration, there was a decrease in the rate of mineralization due to the occurrence of inefficient reactions. These results demonstrate the importance of evaluating the operational parameters, such as the concentrations of Fenton´s reagents, in order to optimize the efficiency of the photodegradation process, as well as reduce the costs of processes with chemical reagents. Thus, the best concentrations obtained experimentally in deionized water (DW) in relation to the operational parameters evaluated considering the CIP mineralization using artificial radiation were: [Fe3+] = 11.2 mg L-1 and [H2O2] = 340 mg L-1. Under these experimental conditions, the influence of different aqueous matrices (simulated seawater - SW and treated effluent from sewage treatment plant - STP) in the CIP degradation was evaluated, and the results were compared to those obtained in DW. Complete removal of CIP (considering the LQ equipment) was influenced by the composition of the matrices, since in DW occurred after 2 minutes of the photo-Fenton process, while 10 minutes were required in SW and STP effluent. This is probably due to the presence of inorganic anions (chloride and sulphate) in SW, which form stable complexes with iron, and also act as scavengers of hydroxyl radicals, as well as by the presence of natural organic matter present in the effluent of STP, which also competes with the target-compound by hydroxyl radicals, influencing the degradation process. Based on the results obtained in this work, it was observed that the photo-Fenton process can be an alternative of treatment to waters containing CIP, since there was complete removal of CIP (considering the LQ equipment) after only 2 minutes, followed by 75% of DOC removal and reduction of acute toxicity to A. saline from 76.7% ± 4.7% to 20.0% ± 10.0% after 60 minutes. Since several ecotoxicological effects are associated with waste pharmaceuticals, in specific antibiotics, in aquatic environments and conventional processes fail to remove them efficiently, the application of this process appears quite feasible. / Neste trabalho foi avaliada a degradação do antibiótico ciprofloxacino CIP (33,1mg L-1)pelo processo foto-Fenton utilizando radiação artificial. Primeiramente avaliou-se diferentes concentrações de Fe3+ (1,4, 5,6, 11,2 e 16,8 mg L-1) na cinética de remoção de CIP e carbono orgânico dissolvido - COD (mineralização), bem como no consumo de H2O2 utilizando-se 510 mg L-1 de H2O2 e pH 2,5-2,8. A concentração de CIP ficou abaixo do limite de quantificação do equipamento - LQ (< 0,163 mg L-1) em apenas 2 minutos, para todas as concentrações de Fe3+ avaliadas, não sendo possível verificar o efeito deste parâmetro operacional para a remoção de CIP. Em relação aos resultados de mineralização e consumo de H2O2, o melhor ajuste matemático observado para todos os dados experimentais obtidos nos diferentes níveis de concentração de Fe3+ avaliados foi de primeira ordem. Além disso, foi observado que o aumento da concentração de Fe3+ resultou num aumento proporcional na velocidade de mineralização e de consumo de H2O2, sendo a concentração de 11,2 mg L-1 de Fe3+ escolhida para os experimentos posteriores. A seguir, foi avaliado o efeito de diferentes concentrações de H2O2 (85, 170, 340, 510 e 680 mg L-1) na cinética de mineralização de CIP e consumo de H2O2 utilizando a melhor concentração de Fe3+ (11,2 mg L-1), e, em pH 2,5-2,8. Comportamento semelhante ao observado para as diferentes concentrações de Fe3+ foi obtido, melhor ajuste matemático para a mineralização de CIP e consumo de H2O2 sendo de primeira ordem. A velocidade de mineralização de CIP também aumentou proporcionalmente com a concentração de H2O2, contudo até um determinado valor de H2O2 (340 mg L-1). Acima desta concentração, houve um decréscimo na velocidade de mineralização devido à ocorrência de reações ineficientes. Estes resultados, demonstram a importância de avaliar os parâmetros operacionais, tais como as concentrações dos reagentes de Fenton, a fim de otimizar a eficiência do processo de fotodegradação, bem como reduzir os custos dos processos com reagentes químicos. Assim, as melhores concentrações obtidas experimentalmente em água deionizada (AD) em relação aos parâmetros operacionais avaliados considerando a mineralização de CIP utilizando radiação artificial foram: [Fe3+] = 11,2 mg L-1 e [H2O2] = 340 mg L-1. Sob tais condições experimentais, a influência de diferentes matrizes aquosas (água de mar simulada AM, e, efluente tratado de estação de tratamento de esgoto - ETE) na degradação de CIP foi avaliada, e os resultados foram comparados aos obtidos em AD. A completa remoção de CIP (considerando o LQ do equipamento) foi influenciada pela composição da matriz, uma vez que em AD ocorreu após 2 minutos do processo foto-Fenton, enquanto que 10 minutos foram necessários para a AM e efluente de ETE. Isto ocorreu provavelmente devido à presença de ânions inorgânicos (cloreto e sulfato) em AM, os quais formam complexos estáveis com ferro, e que também atuam como sequestradores de radicais hidroxilas, assim como pela presença de matéria orgânica natural presente no efluente de ETE, a qual também compete com o composto-alvo pelos radicais hidroxila, influenciando assim o processo de degradação. Baseado nos resultados obtidos neste trabalho pode ser observado que o processo foto-Fenton pode ser uma alternativa de tratamento de águas contendo CIP, pois houve completa remoção de CIP (considerando o LQ do equipamento) após apenas 2 minutos, seguido de 75% de remoção de COD e redução da toxicidade aguda para A. salina de 76,7% ± 4,7% para 20,0% ± 10,0% após 60 minutos. Visto que vários efeitos ecotoxicológicos estão associados aos resíduos de fármacos, em específico antibióticos, presentes nos ambientes aquáticos e que os processos convencionais não conseguem removê-los eficientemente, a aplicação deste processo se mostra bastante viável. / Mestre em Química
10

​​USE OF ALGAE, CYANOBACTERIA, AND INDIGENOUS BACTERIA FOR THE SUSTAINABLE TREATMENT OF AQUACULTURE WASTEWATER​<b> </b>

Yolanys Nadir Aranda Vega (18433941) 27 April 2024 (has links)
<p dir="ltr">Aquaculture is a controlled aquatic farming sector and one of the most important human food sources. Fish farming is one of the predominant, fast-growing sectors that supply seafood products worldwide. Along with its benefits, aquaculture practices can discharge large quantities of nutrients into the environment through non-treated or poorly treated wastewater. This study aims to understand the nutrient composition of fish wastewater and the use of indigenous bacteria, cyanobacteria, and microalgae as an alternative biological treatment method. Wastewater samples from a local fish farming facility were collected and treated using six different species of cyanobacteria and microalgae include <i>Chroococcus</i><i> </i><i>minutus</i>, <i>Porphyridium</i><i> </i><i>cruentum</i>, <i>Chlorella vulgaris</i>, <i>Microcystis aeruginosa</i>, <i>Chlamydomonas </i><i>reinhardtii</i>, and <i>Fischerella</i><i> </i><i>muscicola</i>. All the samples were incubated for 21 days, and the following parameters were measured weekly: Chemical oxygen demand (COD), phosphate, total dissolved nitrogen, and dissolved inorganic nitrogen. In addition, dissolved organic nitrogen (DON), bioavailable DON (ABDON), and biodegradable DON (BDON) were calculated from the mass-balance equations. Colorimetric and digestive methods were used for the parameter measurements. The results showed that <i>C. </i><i>reinhardtii</i> reduced the soluble COD concentration by 74.6%, DON by 94.3%, and phosphorous by more than 99%. Moreover, <i>M. aeruginosa</i>, and <i>C. </i><i>minutus</i> significantly reduced inorganic nitrogen species (>99%). This alternative fish wastewater treatment method was explored to gain insight into fish wastewater nutrient composition and to create a sustainable alternative to conventional fish wastewater treatment methods.<b> </b></p>

Page generated in 0.0846 seconds