Spelling suggestions: "subject:"tubular joints"" "subject:"lubular joints""
1 |
Stress analysis and design of some pressure vessel and piping componentsMoffat, Douglas G. January 2000 (has links)
No description available.
|
2 |
Redes neurais artificiais na avaliação de concentração de tensões em juntas tubulares soldadas. / Artificial neural networks to calculate stress concentration factors in welded tubular joints.Cardoso, Ademar de Azevedo 30 April 1999 (has links)
Neste trabalho está apresentada uma alternativa para o cálculo do fator de concentração de tensões (FCT) em juntas tubulares soldadas do tipo Y. Redes Neurais Artificiais (RNA) foram utilizadas para representar a distribuição de tensões ao longo da junta tubular para os casos de carregamento força axial no plano e momento fletor no plano. As RNA podem aprender a partir de um conjunto de dados sem a necessidade de uma expressão matemática entre as variáveis dependentes e independentes; representa uma vantagem sobre o procedimento normalmente utilizado, ou seja, as equações paramétricas. O modelo proposto representa um avanço no projeto de juntas tubulares, uma vez que evita a necessidade de se conhecer uma expressão matemática para representar a distribuição de tensões na junta e fornece um método mais preciso para avaliar a distribuição de tensões ao longo da junta soldada. O conjunto de dados utilizado foi formado a partir de simulações numéricas das juntas soldadas através do MEF, nas quais foi considerada a geometria do cordão de solda. / An alternative approach to calculate stress concentration factors (SCF) in Y-type welded tubular joints is presented. Artificial Neural Networks (ANN) were used to represent the stress distribution along the tubular joints in both in-plane axial force and in-plane bending moment load cases. ANN can learn from a database without establishing a mathematical expression between dependent and independent variables, which is an advantage over the usual parametric equations approach. The proposed model represents an improvement in the tubular joints design, since it avoids the previous knowing of a mathematical expression to represent the stress distribution in the joint and provides an accurate method to evaluate the stress distribution along the welded fillet joint. The database herein used was completed with FE simulations of tubular joints which consider the geometry of the weld fillet.
|
3 |
Redes neurais artificiais na avaliação de concentração de tensões em juntas tubulares soldadas. / Artificial neural networks to calculate stress concentration factors in welded tubular joints.Ademar de Azevedo Cardoso 30 April 1999 (has links)
Neste trabalho está apresentada uma alternativa para o cálculo do fator de concentração de tensões (FCT) em juntas tubulares soldadas do tipo Y. Redes Neurais Artificiais (RNA) foram utilizadas para representar a distribuição de tensões ao longo da junta tubular para os casos de carregamento força axial no plano e momento fletor no plano. As RNA podem aprender a partir de um conjunto de dados sem a necessidade de uma expressão matemática entre as variáveis dependentes e independentes; representa uma vantagem sobre o procedimento normalmente utilizado, ou seja, as equações paramétricas. O modelo proposto representa um avanço no projeto de juntas tubulares, uma vez que evita a necessidade de se conhecer uma expressão matemática para representar a distribuição de tensões na junta e fornece um método mais preciso para avaliar a distribuição de tensões ao longo da junta soldada. O conjunto de dados utilizado foi formado a partir de simulações numéricas das juntas soldadas através do MEF, nas quais foi considerada a geometria do cordão de solda. / An alternative approach to calculate stress concentration factors (SCF) in Y-type welded tubular joints is presented. Artificial Neural Networks (ANN) were used to represent the stress distribution along the tubular joints in both in-plane axial force and in-plane bending moment load cases. ANN can learn from a database without establishing a mathematical expression between dependent and independent variables, which is an advantage over the usual parametric equations approach. The proposed model represents an improvement in the tubular joints design, since it avoids the previous knowing of a mathematical expression to represent the stress distribution in the joint and provides an accurate method to evaluate the stress distribution along the welded fillet joint. The database herein used was completed with FE simulations of tubular joints which consider the geometry of the weld fillet.
|
4 |
Comportamento estrutural de ligações tubulares T e KT. / Comportamento estrutural de ligações tubulares do tipo T e KT behavior of structural hollow section joints type "T" and "KT".Nívia dos Santos Lima 01 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os perfis tubulares sem costura são largamente utilizados em diversos países, porém, no Brasil, o uso desses perfis era bastante limitado, restringindo-se praticamente a coberturas espaciais. A situação do mercado brasileiro começou a se alterar em razão da maior oferta desses perfis proporcionada pelo início da produção pela V&M do BRASIL no ano de 2000, sendo assim diante da novidade da tecnologia, impõe-se a necessidade de divulgação e implementação do uso desse tipo de perfil, além de uma ampliação do número de trabalhos de pesquisa para melhor compreensão de seu comportamento estrutural. O presente trabalho apresenta uma análise paramétrica de ligações tipo KT e T, através da determinação da resistência última da ligação obtida pelo critério de deformação limite proposto por diversos pesquisadores, comparando os resultados com as prescrições do Eurocode 3, do Projeto de Norma Brasileira e do CIDECT. Adicionalmente procedeu-se na comparação do comportamento numérico global do nó de uma treliça, com a análise do comportamento numérico do nó isolado. As ligações objeto deste estudo são compostas por perfil tubular retangular (RHS) no banzo e perfis circulares (CHS) nas diagonais e montantes. Os modelos em elementos finitos, foram desenvolvidos no programa Ansys 12.0, as não-linearidades físicas e geométricas foram incorporadas aos modelos, a fim de se mobilizar totalmente a capacidade resistente da ligação. Concluiu-se entre outras coisas que.
para o nó da treliça em estudo neste trabalho, o carregamento de projeto máximo permitido através do dimensionamento pelas normas fica a favor da segurança quando comparado com o critério de deformação limite. / The hollow section seamless are widely used in many countries, however, in Brazil, the use of these section was rather limited, being restricted to just the spatial roof. The situation of the Brazilian market began to change due to the increased supply of these section provided by the start of production by V&M do BRASIL in 2000, thus before the novelty of the technology, imposes the need to disseminate and implement the use of section type, and an increased number of research studies to better understand its structural behavior. This study presents a parametric analysis of joints type "KT" and "T", by determining the ultimate strength of the joint obtained by the criterion of deformation limit proposed by several researchers, comparing the results with the requirements of Eurocode 3, Project Brazilian Standard and CIDECT Additionally we proceeded to compare the behavior of the global node number of a truss, with the numerical analysis of the behavior of the isolated node. The joint object of this study are composed of rectangular hollow section (RHS) in the chord and circular hollow section (CHS) on the brace member. The finite element models were developed in the program Ansys 12.0. The non-linearities physical and geometric have been incorporated in the models, to mobilize the full load capacity of the joint. It was concluded among other things for the node of the truss studied in this work, the maximum allowable loading project through the design standards is to promote security when compared with the criterion limit of deformation.
|
5 |
Comportamento estrutural de ligações tubulares T e KT. / Comportamento estrutural de ligações tubulares do tipo T e KT behavior of structural hollow section joints type "T" and "KT".Nívia dos Santos Lima 01 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os perfis tubulares sem costura são largamente utilizados em diversos países, porém, no Brasil, o uso desses perfis era bastante limitado, restringindo-se praticamente a coberturas espaciais. A situação do mercado brasileiro começou a se alterar em razão da maior oferta desses perfis proporcionada pelo início da produção pela V&M do BRASIL no ano de 2000, sendo assim diante da novidade da tecnologia, impõe-se a necessidade de divulgação e implementação do uso desse tipo de perfil, além de uma ampliação do número de trabalhos de pesquisa para melhor compreensão de seu comportamento estrutural. O presente trabalho apresenta uma análise paramétrica de ligações tipo KT e T, através da determinação da resistência última da ligação obtida pelo critério de deformação limite proposto por diversos pesquisadores, comparando os resultados com as prescrições do Eurocode 3, do Projeto de Norma Brasileira e do CIDECT. Adicionalmente procedeu-se na comparação do comportamento numérico global do nó de uma treliça, com a análise do comportamento numérico do nó isolado. As ligações objeto deste estudo são compostas por perfil tubular retangular (RHS) no banzo e perfis circulares (CHS) nas diagonais e montantes. Os modelos em elementos finitos, foram desenvolvidos no programa Ansys 12.0, as não-linearidades físicas e geométricas foram incorporadas aos modelos, a fim de se mobilizar totalmente a capacidade resistente da ligação. Concluiu-se entre outras coisas que.
para o nó da treliça em estudo neste trabalho, o carregamento de projeto máximo permitido através do dimensionamento pelas normas fica a favor da segurança quando comparado com o critério de deformação limite. / The hollow section seamless are widely used in many countries, however, in Brazil, the use of these section was rather limited, being restricted to just the spatial roof. The situation of the Brazilian market began to change due to the increased supply of these section provided by the start of production by V&M do BRASIL in 2000, thus before the novelty of the technology, imposes the need to disseminate and implement the use of section type, and an increased number of research studies to better understand its structural behavior. This study presents a parametric analysis of joints type "KT" and "T", by determining the ultimate strength of the joint obtained by the criterion of deformation limit proposed by several researchers, comparing the results with the requirements of Eurocode 3, Project Brazilian Standard and CIDECT Additionally we proceeded to compare the behavior of the global node number of a truss, with the numerical analysis of the behavior of the isolated node. The joint object of this study are composed of rectangular hollow section (RHS) in the chord and circular hollow section (CHS) on the brace member. The finite element models were developed in the program Ansys 12.0. The non-linearities physical and geometric have been incorporated in the models, to mobilize the full load capacity of the joint. It was concluded among other things for the node of the truss studied in this work, the maximum allowable loading project through the design standards is to promote security when compared with the criterion limit of deformation.
|
6 |
Avaliação da influência do esforço normal no banzo no comportamento de ligações tubulares em aço. / Analysis of the influence of chord normal stresses on the behavior of hollow sections connections.Adriano Nizer 12 March 2014 (has links)
A demanda pelo uso de perfis tubulares em estruturas na construção civil tem tido grande avanço no Brasil, apesar de ser, há muito tempo, amplamente empregado na Europa e países desenvolvidos. O lançamento de uma norma técnica brasileira específica para dimensionamento de perfis tubulares confirma esta tendência, havendo então a necessidade de uma maior divulgação e execução de estudos e trabalhos de pesquisa para uma melhor compreensão e desenvolvimento desta tecnologia. O presente trabalho apresenta uma análise da influência da aplicação de esforço normal no banzo no comportamento de ligações tubulares do tipo T. No desenvolvimento deste trabalho, foram realizados seis ensaios em laboratório com ligações do tipo T com perfis do tipo RHS para o banzo e SHS para o montante, sendo utilizados perfis conformados a frio para composição das ligações ensaiadas. Do total dos ensaios foram executados dois ensaios sem aplicação de esforço normal no banzo; dois com aplicação de esforço normal de compressão e dois com aplicação de esforço normal de tração. A resistência última das ligações nos ensaios foi obtida por meio do Critério de Deformação Limite proposto por diversos pesquisadores. Estes resultados foram comparados com os resultados obtidos em modelos numéricos em elementos finitos desenvolvidos no programa ANSYS 12.0, sendo considerado nestes modelos as não-linearidades geométricas e de material. Estes resultados também foram comparados com os resultados teóricos obtidos com base nas prescrições constantes nas normas Eurocode 3; norma brasileira NBR 16239 e do CIDECT. Conclui-se com este estudo que os resultados obtidos tanto nos ensaios experimentais quanto nos modelos numéricos ficaram a favor da segurança quando comparados com os valores teóricos obtidos pelas normas Eurocode 3 e NBR 16239:2013 e CIDECT com o banzo sem aplicação de esforço normal e com aplicação de esforço normal de compressão de até 60% e 80 % da carga de plastificação do banzo, respectivamente, para o Eurocode 3/NBR16239:2013 e para o CIDECT. As resistências obtidas para as ligações com a aplicação de esforço normal de tração no banzo foram superiores aos resultados teóricos no caso estudado. / The demand for the use of hollow sections structures in construction has had great progress in Brazil, despite being a long time widely used in Europe and developed countries. The release of a Brazilian Technical Standard specific for design of hollow sections, confirms this trend, and the need for increased dissemination and implementation of studies and research for a better understanding and development of this technology. This paper presents an analysis of the influence of chord normal stresses on the behavior of hollow sections connections, specifically for a T tubular joint. The experimental program consisted of six tests where two experiments were executed without chord axial forces, two were performed with compressive axial forces and two tension axial forces. The tested joints ultimate strengths were determined using deformation limit criteria proposed by several researchers. These results were then compared to the results obtained from a finite element numerical model developed 12.0 ANSYS program that included geometrical and material nonlinearities. These results were also compared to the design provisions present at the Eurocode 3; Brazilian standard NBR 16239:2013 and CIDECT. This assessment indicated that the results obtained in both experimental tests and in the numerical models were in favor of security when compared to the theoretical values obtained by all the investigated standards for chords without axial forces and with compressive axial forces corresponding to 60% and 80% of the chord plastic resistance, respectively, according to Eurocode 3/NBR16239:2013 and CIDECT. The obtained resistances for the joints applying tensile axial force on the chord were superior to the predicted theoretical results in the studied cases.
|
7 |
Avaliação da influência do esforço normal no banzo no comportamento de ligações tubulares em aço. / Analysis of the influence of chord normal stresses on the behavior of hollow sections connections.Adriano Nizer 12 March 2014 (has links)
A demanda pelo uso de perfis tubulares em estruturas na construção civil tem tido grande avanço no Brasil, apesar de ser, há muito tempo, amplamente empregado na Europa e países desenvolvidos. O lançamento de uma norma técnica brasileira específica para dimensionamento de perfis tubulares confirma esta tendência, havendo então a necessidade de uma maior divulgação e execução de estudos e trabalhos de pesquisa para uma melhor compreensão e desenvolvimento desta tecnologia. O presente trabalho apresenta uma análise da influência da aplicação de esforço normal no banzo no comportamento de ligações tubulares do tipo T. No desenvolvimento deste trabalho, foram realizados seis ensaios em laboratório com ligações do tipo T com perfis do tipo RHS para o banzo e SHS para o montante, sendo utilizados perfis conformados a frio para composição das ligações ensaiadas. Do total dos ensaios foram executados dois ensaios sem aplicação de esforço normal no banzo; dois com aplicação de esforço normal de compressão e dois com aplicação de esforço normal de tração. A resistência última das ligações nos ensaios foi obtida por meio do Critério de Deformação Limite proposto por diversos pesquisadores. Estes resultados foram comparados com os resultados obtidos em modelos numéricos em elementos finitos desenvolvidos no programa ANSYS 12.0, sendo considerado nestes modelos as não-linearidades geométricas e de material. Estes resultados também foram comparados com os resultados teóricos obtidos com base nas prescrições constantes nas normas Eurocode 3; norma brasileira NBR 16239 e do CIDECT. Conclui-se com este estudo que os resultados obtidos tanto nos ensaios experimentais quanto nos modelos numéricos ficaram a favor da segurança quando comparados com os valores teóricos obtidos pelas normas Eurocode 3 e NBR 16239:2013 e CIDECT com o banzo sem aplicação de esforço normal e com aplicação de esforço normal de compressão de até 60% e 80 % da carga de plastificação do banzo, respectivamente, para o Eurocode 3/NBR16239:2013 e para o CIDECT. As resistências obtidas para as ligações com a aplicação de esforço normal de tração no banzo foram superiores aos resultados teóricos no caso estudado. / The demand for the use of hollow sections structures in construction has had great progress in Brazil, despite being a long time widely used in Europe and developed countries. The release of a Brazilian Technical Standard specific for design of hollow sections, confirms this trend, and the need for increased dissemination and implementation of studies and research for a better understanding and development of this technology. This paper presents an analysis of the influence of chord normal stresses on the behavior of hollow sections connections, specifically for a T tubular joint. The experimental program consisted of six tests where two experiments were executed without chord axial forces, two were performed with compressive axial forces and two tension axial forces. The tested joints ultimate strengths were determined using deformation limit criteria proposed by several researchers. These results were then compared to the results obtained from a finite element numerical model developed 12.0 ANSYS program that included geometrical and material nonlinearities. These results were also compared to the design provisions present at the Eurocode 3; Brazilian standard NBR 16239:2013 and CIDECT. This assessment indicated that the results obtained in both experimental tests and in the numerical models were in favor of security when compared to the theoretical values obtained by all the investigated standards for chords without axial forces and with compressive axial forces corresponding to 60% and 80% of the chord plastic resistance, respectively, according to Eurocode 3/NBR16239:2013 and CIDECT. The obtained resistances for the joints applying tensile axial force on the chord were superior to the predicted theoretical results in the studied cases.
|
8 |
Análise de ligações tubulares T com reforço de chapa. / Evaluation of T tubular joints reinforced with plates.Douglas Rodriguez Brasil 01 March 2013 (has links)
O uso de perfis estruturais tubulares vem aumentando em grande escala no mundo, principalmente devido às vantagens associadas ao comportamento estrutural e estético, levando a uma intensa utilização nos países da Europa, Sudeste Asiático, América do Norte e na Austrália. Países como Canadá, Inglaterra, Alemanha e Holanda fazem uso intensivo dessas estruturas e contam com uma produção corrente, industrializada e contínua com alto grau de desenvolvimento tecnológico. Diante deste fato, no Brasil, o uso desses perfis era bastante limitado, restringindo-se praticamente a coberturas espaciais. A situação do mercado brasileiro começou a se alterar em razão da maior oferta desses perfis proporcionada pelo início da produção pela V&M do BRASIL no ano de 2000. Sendo assim, diante da novidade da tecnologia, impõe-se a necessidade de divulgação e implementação do uso desse tipo de perfil, além de uma ampliação do número de trabalhos de pesquisa para melhor compreensão de seu comportamento estrutural. O presente trabalho apresenta uma análise paramétrica de ligação reforçada tipo T, através da determinação da resistência última da ligação obtida pelo critério de deformação limite proposto por diversos pesquisadores, comparando os resultados com as prescrições do Eurocode 3, do Projeto de Norma Brasileira PN 02.125.03-004 e do CIDECT. As ligações objeto deste estudo são compostas por perfil tubular retangular (RHS) no banzo e perfis circulares (CHS) nos montantes. Nestas análises verificou-se a influência do reforço na região de encontro de banzo e montante, bem como a influência do esforços atuantes no banzo no comportamento global das ligações. As não-linearidades físicas e geométricas foram incorporadas aos modelos, a fim de se mobilizar totalmente a capacidade resistente dessa ligação. Os modelos em elementos finitos, foram desenvolvidos no programa Ansys 12.0. Como resultado final deste trabalho é apresentado o comportamento da ligação tipo T com reforço para diversos tipos de perfis (banzo e montante) e diferentes espessuras da chapa de reforço, fazendo comparação com o dimensionamento proposto pelo Projeto de Norma Brasileira PN 02.125.03-004. / The use of tubular structural profiles has increased in large-scale worldwide, mainly because of the technical advantages associated with the structural behavior and aesthetic, led to an intense use in Europe, Southeast Asia, North America and Australia. Countries like Canada, England, Germany and Netherlands make use these structures and have a current, industrialized and continuing production with a high level of technological development. Considering this fact, in Brazil, the use of these profiles has been quite limited, being restricted just to spatial coverage. Nonetheless situation in the Brazilian market has changed due to the supply of these profiles provided by the start of production from V&M do BRASIL in the year 2000, in front of this technological novelty, imposing the need for dissemination and implemation of the use of this type of profile, as well as an increase in the number of research papers providing a better understanding of its structural behavior. This dissertation presents a parametric analysis of reinforced T-joints by determining the joint ultimate strength obtained by the limit deformation criteria proposed by several researchers comparing the results with Eurocode 3, Brazilian Design Code Project PN 02.125.03-004 and CIDECT requirements. The joints object of this study are composed by tubular rectangular hollow section (RHS) in the chord and circular hollow section (CHS) in the braces. In these analyzes, it was verified the influence of reinforcements in the area against of the chord and brace, as well as the influence of acting efforts in the chord in the joint global behavior. The physical and geometrical nonlinearities were incorporated in the models, in order to fully mobilize the joint resistance capacity. The finite element method was developed with the Ansys 12.0 software. As final results of this dissertation, it is presented the reinforced T-joint behavior for several profile types (chord and brace) and different thicknesses reinforcement plates, in comparison to the design proposed by Brazilian Design Code Project PN 02.125.03-004
|
9 |
Análise de ligações tubulares T com reforço de chapa. / Evaluation of T tubular joints reinforced with plates.Douglas Rodriguez Brasil 01 March 2013 (has links)
O uso de perfis estruturais tubulares vem aumentando em grande escala no mundo, principalmente devido às vantagens associadas ao comportamento estrutural e estético, levando a uma intensa utilização nos países da Europa, Sudeste Asiático, América do Norte e na Austrália. Países como Canadá, Inglaterra, Alemanha e Holanda fazem uso intensivo dessas estruturas e contam com uma produção corrente, industrializada e contínua com alto grau de desenvolvimento tecnológico. Diante deste fato, no Brasil, o uso desses perfis era bastante limitado, restringindo-se praticamente a coberturas espaciais. A situação do mercado brasileiro começou a se alterar em razão da maior oferta desses perfis proporcionada pelo início da produção pela V&M do BRASIL no ano de 2000. Sendo assim, diante da novidade da tecnologia, impõe-se a necessidade de divulgação e implementação do uso desse tipo de perfil, além de uma ampliação do número de trabalhos de pesquisa para melhor compreensão de seu comportamento estrutural. O presente trabalho apresenta uma análise paramétrica de ligação reforçada tipo T, através da determinação da resistência última da ligação obtida pelo critério de deformação limite proposto por diversos pesquisadores, comparando os resultados com as prescrições do Eurocode 3, do Projeto de Norma Brasileira PN 02.125.03-004 e do CIDECT. As ligações objeto deste estudo são compostas por perfil tubular retangular (RHS) no banzo e perfis circulares (CHS) nos montantes. Nestas análises verificou-se a influência do reforço na região de encontro de banzo e montante, bem como a influência do esforços atuantes no banzo no comportamento global das ligações. As não-linearidades físicas e geométricas foram incorporadas aos modelos, a fim de se mobilizar totalmente a capacidade resistente dessa ligação. Os modelos em elementos finitos, foram desenvolvidos no programa Ansys 12.0. Como resultado final deste trabalho é apresentado o comportamento da ligação tipo T com reforço para diversos tipos de perfis (banzo e montante) e diferentes espessuras da chapa de reforço, fazendo comparação com o dimensionamento proposto pelo Projeto de Norma Brasileira PN 02.125.03-004. / The use of tubular structural profiles has increased in large-scale worldwide, mainly because of the technical advantages associated with the structural behavior and aesthetic, led to an intense use in Europe, Southeast Asia, North America and Australia. Countries like Canada, England, Germany and Netherlands make use these structures and have a current, industrialized and continuing production with a high level of technological development. Considering this fact, in Brazil, the use of these profiles has been quite limited, being restricted just to spatial coverage. Nonetheless situation in the Brazilian market has changed due to the supply of these profiles provided by the start of production from V&M do BRASIL in the year 2000, in front of this technological novelty, imposing the need for dissemination and implemation of the use of this type of profile, as well as an increase in the number of research papers providing a better understanding of its structural behavior. This dissertation presents a parametric analysis of reinforced T-joints by determining the joint ultimate strength obtained by the limit deformation criteria proposed by several researchers comparing the results with Eurocode 3, Brazilian Design Code Project PN 02.125.03-004 and CIDECT requirements. The joints object of this study are composed by tubular rectangular hollow section (RHS) in the chord and circular hollow section (CHS) in the braces. In these analyzes, it was verified the influence of reinforcements in the area against of the chord and brace, as well as the influence of acting efforts in the chord in the joint global behavior. The physical and geometrical nonlinearities were incorporated in the models, in order to fully mobilize the joint resistance capacity. The finite element method was developed with the Ansys 12.0 software. As final results of this dissertation, it is presented the reinforced T-joint behavior for several profile types (chord and brace) and different thicknesses reinforcement plates, in comparison to the design proposed by Brazilian Design Code Project PN 02.125.03-004
|
Page generated in 0.0572 seconds