• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ultrassonografia mamária: concordância entre exames realizados externamente e dentro de um centro especializado em radiologia mamária

PONTUAL, Mariana Vila Nova de Oliveira 13 March 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-31T20:05:01Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Mariana Vila Nova de Oliveira Pontual.pdf: 2162165 bytes, checksum: 9f86b45a02e8daa98d511dca09819553 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-17T21:27:45Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Mariana Vila Nova de Oliveira Pontual.pdf: 2162165 bytes, checksum: 9f86b45a02e8daa98d511dca09819553 (MD5) / Made available in DSpace on 2018-09-17T21:27:45Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Mariana Vila Nova de Oliveira Pontual.pdf: 2162165 bytes, checksum: 9f86b45a02e8daa98d511dca09819553 (MD5) Previous issue date: 2017-03-13 / A USG é um método diagnóstico consolidado na avaliação de nódulos mamários benignos e malignos. A concordância interobservador na descrição dos nódulos é um problema relacionado ao seu uso. O sistema BI-RADSᵀᴹ foi criado no intuito de uniformizar os relatórios e sugerir conduta. A experiência do examinador em radiologia mamária influencia a qualidade do exame e a concordância interobservador. Os objetivos principais foram a análise da concordância interobservador na descrição de nódulos sólidos mamários, a frequência do uso do BI-RADSᵀᴹ, e a avaliação de medidas de eficácia dos exames comparando-se exames realizados externamente (exame externo) e dentro de um centro especializado em radiologia mamária (exame interno). Foram comparadas USGs de 62 pacientes. Calculou-se o coeficiente de kappa quando o mesmo nódulo foi descrito em ambos os exames (n=49) para os descritores ecogenicidade e margens e também calculou-se este mesmo coeficiente quando ambos os exames expressaram a classificação BI-RADSᵀᴹ (n=44). Em 48 casos foi realizada biópsia e analisados VPP, VPN, sensibilidade e especificidade dos exames externo e interno levando em consideração os critérios de margem circunscrita e não-circunscrita. O uso da classificação BI-RADSᵀᴹ foi mais frequente nos exames internos. A concordância entre os exames externo e interno foi leve para ecogenicidade (k = 0,39) e para a classificação BI-RADSᵀᴹ (k = 0,40), confirmando as limitações do método já observadas na literatura. Houve concordância substancial para o descritor margens (k = 0,69), para nódulos hipoecogênicos (k = 0,62) e para a categoria B5 (k = 0,64). Observou-se grande percentual de nódulos B3 que foram submetidos à biópsia nos exames externos e internos, contrariando a recomendação teórica para esta categoria. Entre os exames internos, observou-se maior sensibilidade, especificidade, bem como maior valor preditivo positivo e negativo, quando comparados aos exames externos. / Ultrasound (US) is a consolidated diagnostic method in the evaluation of benign and malignant mammary nodules. Interobserver agreement in the description of nodules is a problem related to its use. The BI-RADSᵀᴹ system was designed to standardize reporting and suggest conduct. The examiner's experience in breast radiology influences the quality of the examination and interobserver agreement. The main objectives were the analysis of the interobserver agreement in the description of solid breast nodules at US, the frequency of BI-RADSᵀᴹ use, and the evaluation of measures of efficacy of the tests comparing externally performed examinations (external examination) and USs performed within a specialized center in breast radiology (internal examination). USGs of 62 patients were compared. The kappa coefficient was calculated when the same nodule was described in both exams (n = 49) for the descriptors echogenicity and margins and the same coefficient was also calculated when both exams expressed the BI-RADSᵀᴹ classification (n = 44). In 48 cases, biopsies were performed and PPV, NPV, sensitivity and specificity of the external and internal exams were analyzed using the circumscribed and non-circumscribed margin criteria. The use of the BI-RADSᵀᴹ classification was more frequent in internal examinations. The concordance between external and internal examinations was mild for echogenicity (k = 0.39) and for the BI-RADSᵀᴹ classification (k = 0.40), confirming the limitations of the method already observed in the literature. There was substantial agreement for the descriptor margins (k = 0.69), for hypoechogenic nodules (k = 0.62) and for category B5 (k = 0.64). It was observed a large percentage of B3 nodules that were submitted to biopsy, contrary to the theoretical recommendation for this category. Internal examinations demonstrated greater sensitivity, specificity and greater positive and negative predictive value when compared to the external examinations.
2

Estimativa pré-operatória do tamanho do câncer mamário : correlação entre exame clínico, mamografia, ultra-sonografia e histopatológico / Estimate pré-operatória of the size of the mammary cancer : correlation between clinical examination, mamografia, ultra-sonografia and histopatológico

Moura, Sammya Bezerra Maia e Holanda January 2007 (has links)
MOURA, Sammya Bezerra Maia e Holanda. Estimativa pré-operatória do tamanho do câncer mamário : correlação entre exame clínico, mamografia, ultra-sonografia e histopatológico. 2007. 66 f. Dissertação (Mestrado em Tocoginecologia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2007. / Submitted by denise santos (denise.santos@ufc.br) on 2013-12-26T11:49:14Z No. of bitstreams: 1 2007_dis_sbmhmoura.pdf: 662350 bytes, checksum: ba740d8fa7655761649a22b9449edf40 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-12-26T11:49:46Z (GMT) No. of bitstreams: 1 2007_dis_sbmhmoura.pdf: 662350 bytes, checksum: ba740d8fa7655761649a22b9449edf40 (MD5) / Made available in DSpace on 2013-12-26T11:49:46Z (GMT). No. of bitstreams: 1 2007_dis_sbmhmoura.pdf: 662350 bytes, checksum: ba740d8fa7655761649a22b9449edf40 (MD5) Previous issue date: 2007 / Objective: To establish the correlation between clinical exam, mammography and sonography, to evaluate the most accurate method of pre-operative assessment of breast cancer. Patients and metods: diagnostic technic validation study. There were selected prospectively 29 women who present suspicious palpable breast tumors in UFC from January to August 2007. There were included the confirmed palpable breast cancer proposed to primary surgery. There were excluded the multicentric cancers, that ones proposed to neo-adjuvant chemotherapy and that ones that did not appear in mammography and/or ultrasound, totalizing 20 cases. The tumors were measured for clinical exam (Tc), ultrasound (Ts) and mammography (Tm) for two different professionals. It was registered the larger measurement in each method studied it was correlated to the measurement obtained from the fresh surgical especimen (Tp). It was also estimated the interobserver variation to each method. Results: the patients were 53,6 years-old. The tumor size obtained was: Tc= 34.32 + 4.06; Ts= 30.70 + 4.91; Tm= 30.97 + 4.20 and Tp= 31.60 + 3.54. There was agreement in the staging: for Tc in 70% (k=0.471); for Tm in 75% (k = 0.598) and for Ts in 85% (k=0.758). Considering Pearson index, there was a good correlation between the observers to: clinical exam (r= 0.986), ultrasound (r= 0.984) and mammography (r = 0.991).The linear correlation between the exams and pathology were: between Tc and Tp, r = 0.882; between Ts and Tp, r = 0.916 and between Tm and Tp, r = 0.919. There was no difference among the variables correlated to the patients or to the tumor, except an inverse correlation between age and tumor size, so that as the age increased, the tumour size decreased in all groups. It was performed Bland and Altman analisys, where the smaller bias was from mammography (0.625 + 7.564). Conclusion: Besides the good correlation of all methods studied and pathology, the mamography was slightly superior to clinical exam and ultrasound in estimative of the pre-operative tumor size in the present study. / Objetivo: estabelecer a correlação entre o exame clínico, mamografia e ultra-sonografia a fim de avaliar o método mais acurado na estimativa pré-operatória do tamanho do câncer de mama. Pacientes e métodos: estudo de validação de técnicas diagnósticas. Foram selecionadas prospectivamente 29 mulheres apresentando tumores mamários suspeitos e palpáveis no Serviço de Mastologia da UFC no período de janeiro a agosto de 2007. Foram incluídos os cânceres de mama palpáveis confirmados e indicados para cirurgia como tratamento inicial. Excluíram-se os cânceres multicêntricos, os indicados para quimioterapia neo-adjuvante e os não identificados pela mamografia e/ou ultra-sonografia, totalizando 20 casos. Os tumores foram medidos por exame clínico (Tc), ultra-sonografia (Ts) e mamografia (Tm) por dois profissionais distintos. Registrou-se a maior medida encontrada em cada método e comparou-se com a medida da peça cirúrgica (Tp). Observou-se ainda a variação interobservador para cada método. Resultados: As pacientes tiveram idade média de 53,6 anos. O tamanho tumoral médio nos exames foi: Tc= 34,32 + 4,06; Ts= 30,70 + 4,91; Tm= 30,97 + 4,20 e Tp= 31,60 + 3,54. Houve concordância no estadiamento: pelo Tc em 70% (k=0,471); pelo Tm em 75% (k= 0,598) e pelo Ts em 85% (k=0,758). Considerando a análise de correlação linear de Pearson houve alta correlação entre os examinadores para o exame clínico (r= 0,986), ultra-sonografia (r = 0,984) e mamografia (r= 0,991). A correlação entre os exames e o histopatológico foi: entre Tc e Tp, r= 0,882; entre Ts e Tp, r= 0,916 e entre Tm e Tp, r = 0,919. Não houve diferença entre variáveis associadas às pacientes ou ao tipo de lesão, exceto uma correlação linear direta com a idade, pois à medida que aumentou a idade, diminuiu o tamanho tumoral entre todos os grupos. Realizou-se a análise de Bland e Altman, onde o menor viés calculado foi o da mamografia (0,625 + 7,564). Conclusão: Apesar de haver boa correlação entre todos os métodos estudados e a análise histopatológica, a mamografia mostrou-se discretamente superior ao exame clínico e à ultra-sonografia na estimativa pré-operatória do tamanho do câncer de mama no presente estudo.
3

Acurácia dos achados mamográficos e ultra-sonográficos do câncer de mama: correlação da classificação BI-RADS quarta edição e achados histológicos

Nascimento, José Hermes Ribas do January 2009 (has links)
Made available in DSpace on 2013-08-07T19:04:02Z (GMT). No. of bitstreams: 1 000410178-Texto+Completo-0.pdf: 10609249 bytes, checksum: 193923c7d5b9630df9b36f33d2b43424 (MD5) Previous issue date: 2009 / Objective: The main aim of the present study is to evaluate the accuracy of Mammography and Ultrasonography (BI-RADS) in the diagnosis of breast cancer and the additional aims are to describe the frequency of different mammographic and ultrasonographic findings as well as to analyze the agreement among observers. Materials and Methods: The mammographic exams of 115 patients and the ultrasonographic exams of 110 patients that had previously undergone core biopsy with previous ultrasonographic evidence of nodules were re-analyzed independently by two (2) specialist doctors, blinded, using the BI-RADS syllabus, evaluation and recommendation, and the latest lexicon for Mammography and Ecography. The citohistologycal findings were used as gold-standard. The accuracy of findings was reached through the analysis of sensibility, specificity and predictive values (positive and negative). The differences among comparison groups were analyzed through x² test for categorical features and the agreement among doctors was calculated through the Cohen’s Kappa statistics. Results: The sensibility of Mammography ranged from 68% to 87%, the NPV from 76% to 83% according to the BI-RADS characteristics. The specificity ranged from 76% to 44% and the PPV from 51% to 53%. The mammographic accuracy ranged from 75% to 62% in the distinction between benign and malignant lesions according to BIRADS. There was a moderate global agreement among the radiologists. The sensibility of Ultrasonography ranged from 70,5% to 82,3%, the NPV from 81,1% to 87,5% and the PPV from 42,1% to 45,1%. The specificity ranged from 56,58% to 55,2% and the accuracy from 60,9% to 63,6%. The evaluation among observers showed a global moderate agreement (k: 0,50) in the analysis of contours, edges, adjacent tissues, posterior acoustic feature, internal echo models and lesion axe in relation to skin, and also showed a low agreement (k: 0,29) in the analysis of nodule edges. Conclusion: The BI-RADS 4th edition was moderately accurate method to standardize the language of doctors in the description of morphological lesions in Mammography and Ultrasonography, although there is considerable variability. Additional efforts to reanalyze specific terms and evaluate diagnostic significance of calcifications may improve the quality of analysis among readers and their accuracy, being regarded as a reference for doctors and patients who may benefit from the use of these data that may support the decision-making process (which patients must undergo biopsy). / Objetivo geral: O objetivo geral do presente estudo é avaliar a acurácia da Mamografia e da Ultra-Sonografia (BIRADS) no diagnóstico de câncer de mama e os objetivos específicos foram descrever a freqüência de apresentação dos diferentes achados mamográficos e ultra-sonográficos e avaliação da concordância entre observadores. Materiais e Métodos: os exames mamográficos de 115 pacientes e os exames ultrasonográficos de 110 pacientes encaminhadas para core biopsy, com diagnóstico prévio ultra-sonográfico, de nódulos mamários, foram re-analisados independentemente por dois (2) médicos especialistas, cegados, utilizando a nomenclatura, avaliação e recomendação do BI-RADS® e o último léxico para Mamografia e Ecografia. Os achados histológicos foram utilizados como padrão-ouro. A acurácia dos achados foi determinada através dos cálculos de sensibilidade, especificidade e dos valores preditivos (positivo e negativo). As diferenças nos grupos de comparação foram analisadas com teste Qui-quadrado para variáveis categóricas e a concordância entre os médicos foi calculada através da estatística Kappa de Cohen. Resultados: A sensibilidade da Mamografia variou entre 68% e 87%, com um VPN de 76% e 83%, das características descritas no BI-RADS. Apresentou uma especificidade, que variou entre 76% e 44% e o VPP variou de 51% e 53%. A acurácia mamográfica oscilou de 75% e 62%, na diferenciação entre lesões benignas de malignas com o uso do BI-RADS. Houve uma concordância global moderada entre os radiologistas. Na Ultra-Sonografia foi obtida uma sensibilidade que variou entre 70,5% e 82,3%, o VPN entre 81,1% e 87,5% e o VPP entre 42,1% e 45,1%. A especificidade variou entre 56,58% e 55,2% e a acurácia entre 60,9% e 63,6%. Na avaliação entre os observadores foi obtida uma concordância global considerada moderada (k: 0,50) para a avaliação dos contornos (formas), margens, tecidos circunvizinhos, característica acústica posterior, modelos dos ecos internos e eixo da lesão em relação à pele e considerada baixa (k: 0,29) na avaliação das bordas dos nódulos. Conclusão: BI-RADS® 4ª edição foi moderadamente acurado em padronizar a linguagem para os médicos descreverem lesões morfológicas na Mamografia e Ultrasonografia, mas existe considerável variabilidade. Esforços para reavaliações de termos específicos e para a avaliação da significância diagnóstica das calcificações podem melhorar a qualidade da avaliação entre leitores e a sua acurácia, sendo desta forma, referencial para médicos e pacientes que poderão definir a tomada de decisão a partir dessas informações (quais pacientes referenciar para a biópsia).
4

Correlação entre o diagnóstico ultrassonográfico pelo sistema BI-RADS e os resultados cito e histopatológicos das lesões mamárias / Correlation enters the ultrassonográfico diagnosis for system BI-RADS and the results I cite and histopatológicos of the mammary injuries

Façanha, Luiz Henrique Ferreira January 2009 (has links)
FAÇANHA, Luiz Henrique Ferreira. Correlação entre o diadnóstico ultrassonográfico pelo sistema BI-RADS e os resultados cito e histopatológicos das lesões mamárias. 2009. 70 f. Dissertação (Mestrado em Tocoginecologia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2009. / Submitted by denise santos (denise.santos@ufc.br) on 2013-12-23T17:27:41Z No. of bitstreams: 1 2009_dis_lhffaçanha.pdf: 1247565 bytes, checksum: fa6a3210de3a7a6e5d9a0eeaa239d6d4 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-12-23T17:28:33Z (GMT) No. of bitstreams: 1 2009_dis_lhffaçanha.pdf: 1247565 bytes, checksum: fa6a3210de3a7a6e5d9a0eeaa239d6d4 (MD5) / Made available in DSpace on 2013-12-23T17:28:33Z (GMT). No. of bitstreams: 1 2009_dis_lhffaçanha.pdf: 1247565 bytes, checksum: fa6a3210de3a7a6e5d9a0eeaa239d6d4 (MD5) Previous issue date: 2009 / Aims: evaluating ultrasound features of breast lesions, by applying them ultrasound BI-RADS (US-BI-RADS) classification, as well as correlating them to their respective cytopathologic and histopathologic diagnoses, collected by fine-needle aspiration biopsy (FNAB), core biopsy, and excision biopsy. Investigating the agreement between US-BI-RADS and cytopathologic FNAB classification to determine benign or malign lesions. Evaluating sensibility, specificity and accuracy of core biopsy, oriented by ultrasonography, in BI-RADS diagnosis for benign and malign lesions determination. Comparing histopathologic core biopsy and excision biopsy results, evaluating the agreement between both methods. Methods: sequential study of 205 patients with breast lesions diagnosed by US-BI-RADS system, from Maternidade-Escola Assis Chateaubriand’s ambulatory, from January of 2007 to July of 2009. After classifying lesions within BI-RADS system, biopsies conducted by ultrasound (FNAB, core biopsy) and excision biopsy were accomplished, and they had their cytopathologic and histopathologic diagnoses evaluated. Statistic analysis was carried out using SPSS 16.0 statistic software for Windows. Data were disposed in tables. Continuous variables were expressed by mean and standard deviation, and categorical variables were expressed by frequency and percentile. BI-RADS classification was evaluated by means of sensibility, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy measurements, taking as a pattern the histopathologic diagnosis that core biopsy and excision biopsy obtained. For evaluating agreement of US-BI-RADS and histopathologic results, this study used the kappa index of concordance, with the significance level of 5%. Results: when FNAB was oriented by ultrasound, this research did not find malignity in category 2, only 1% of malignity in category 3, and 2.5%, 23.1% and 80% (4-A, 4-B, 4-C respectively) in category 4. Category 5 showed 100% of malignity. Insufficient or inadequate results were 17.5%. When the study performed the core biopsy, it did not find malign result in category 2, 2.6% in category 3, and in category 4 it found 10%, 46% and 80% (4-A, 4-B, 4-C respectively). Sensibility was 95.2%, NPV 97.4, and specificity 46.9%. PPV was 31.7% and accuracy 56.9%. The agreement between core biopsy histopathologic result and excision biopsy was 100%. Conclusion: FNAB oriented by ultrasonography showed to be a method with good diagnosis agreement, in benign and malign breast lesions, according to US-BI-RADS, although the occurrence of insufficient or inadequate biopsies was high (17.5%). Core biopsy showed to be a high sensitivity method; nonetheless it shows a low specificity in determining benign and malign lesions, according to US-BI-RADS. When compared with excision biopsy results, core biopsy histopathologic results showed 100% of agreement. / Objetivos: avaliar as características ultrassonográficas das lesões mamárias, classificá-las pelo sistema BI-RADS ultrassonográfico (BI-RADS-US) e correlacioná-las com os seus respectivos diagnósticos cito e histopatógicos, obtidos por PAAF (punção aspirativa por agulha fina), core biopsy e biopsia excisional. Verificar a concordância entre a classificação BI-RADS-US e o citopatológico da PAAF para determinar lesões benignas ou malignas. Avaliar a sensibilidade, a especificidade e a acurácia da core biopsy, orientada pela ultrassonografia, na determinação de lesões benignas e malignas, diagnosticadas de acordo com o BI-RADS-US. Comparar o resultado histopatológico da core biopsy e da biopsia excisional, avaliando a concordância entre os métodos. Metodologia: estudo seqüencial de 205 pacientes de janeiro de 2007 a julho de 2009, com lesões mamárias diagnosticadas pelo sistema BI-RADS ultrassonográfico, oriundas do Ambulatório da Maternidade-Escola Assis Chateaubriand (UFC). Após classificar as lesões em categorias do sistema BI-RADS, foram realizados os procedimentos de biopsias orientados pela ultrassonografia (PAAF, core biopsy) e a biopsia excisional, e avaliados os seus diagnósticos cito e histopatológicos. A análise estatística foi realizada utilizando o software estatístico SPSS 16.0 para Windows. Procedeu-se a disposição dos dados em tabela. Variáveis contínuas foram expressas por média e desvio-padrão e as variáveis categóricas por frequência e porcentagem. A classificação do BI-RADS foi avaliada, por cálculos de sensibilidade, especificidade, VPP (valor preditivo positivo), VPN (valor preditivo negativo) e acurácia, utilizando como padrão o diagnóstico histopatológico obtido pela core biopsy e biopsia excisional. Para se avaliar a concordância da classificação BI-RADS ultrassográfico e o resultado histopatológico, utilizou-se o índice de concordância kappa, com nível de significância de 5%. Resultados: quando se realiza a PAAF orientada por ultrassonografia, não se encontrou malignidade na categoria 2, somente 1% de malignidade na categoria 3, e na categoria 4 foram encontradas 2,5%, 23,1% e 80% (4-A, 4-B e 4C respectivamente). A categoria 5 teve 100% de malignidade. Os resultados insuficientes ou inadequados foram de 17,5%. Quando realizada a core biopsy não se obteve na categoria 2 resultado maligno, 2,6% na categoria 3 e na categoria 4 foram encontrados 10%, 46% e 80% (4-A, 4-B e 4-C respectivamente). A sensibilidade foi de 95,2%, o VPN de 97,4% e a especificidade de 46,9%. O VPP foi de 31,7% e a acurácia de 56,9%. A concordância entre o resultado histopatológico da core biopsy e da biopsia excisional foi de 100%. Conclusão: a PAAF orientada pela ultrassonografia se mostrou um método com uma boa concordância diagnóstica, em lesões benignas e malignas da mama, de acordo com o BI-RADS-US, embora a ocorrência de punções insuficientes ou inadequadas tenha sido elevada (17,5%). A core biopsy mostrou-se um método com alta sensibilidade, porém com uma baixa especificidade, na determinação de lesões benignas e malignas, de acordo com o BI-RADS-US. Quando comparados com os resultados da biopsia excisional, os resultados histopatológicos da core biopsy mostraram uma concordância de 100%.
5

Avaliação das características vasculares dos nódulos sólidos de mama com ultrassonografia Doppler pré e pós-injeção de contraste por microbolhas / Evaluation of vascular characteristics of breast masses with Doppler ultrasound before and after microbubble contrast injection

Daniela Stanzani 14 December 2010 (has links)
INTRODUÇÃO: O duplex-Doppler e a ultrassonografia com contraste são métodos pouco estudados em lesões mamárias. No entanto, em outros órgãos, têm se mostrado úteis na distinção entre lesões benignas e malignas. O objetivo deste trabalho é caracterizar os achados ao Doppler colorido pré e pós-contraste nos nódulos sólidos de mama, correlacionando-os com os resultados anatomopatológicos. MATERIAL E MÉTODOS: Setenta nódulos sólidos da mama foram avaliados por meio de ultrassonografia convencional e duplex-Doppler colorido antes e após a injeção do meio de contraste (ultrassonografia contrastada), no período compreendido entre março de 2007 e janeiro de 2008, e seus resultados foram comparados à análise histológica (padrão-ouro). Todas as pacientes assinaram o Termo de Consentimento Livre e Esclarecido, aprovado pelo Comitê de Ética da FMUSP. O estudo ultrassonográfico modo B avaliou a morfologia do nódulo e o classificou conforme o léxico BI-RADS. Ao duplex-Doppler colorido observou-se a vascularização nodular, descrevendo-se o número de vasos presentes (0 = avascularizado; 1 ou 2 = hipovascularizado, 3 = hipervascularizado), sua morfologia (regular ou tortuoso) e sua distribuição (periférica ou central). Os índices de resistividade e a presença de vaso penetrante também foram avaliados. A partir de dados da literatura criou-se um critério de classificação que permitiu estratificá-los entre provavelmente benigno (nódulos avasculares ou hipovasculares, com vasos regulares e distribuição periférica), provavelmente maligno (nódulos hipervasculares, com vasos tortuosos e distribuição central) ou suspeitos (qualquer outra associação desses fatores). No estudo contrastado foram realizadas análises cinética (avaliando-se os tempos de início da contrastação e do clareamento do nódulo, além da análise da intensidade da contrastação, de maneira subjetiva) e morfológica (utilizando-se os mesmos critérios da análise com Doppler). RESULTADOS: A análise histológica resultou em 25 lesões malignas e 45 lesões benignas. A classificação BI-RADS teve sensibilidade de 100%, especificidade de 66,6%, valor preditivo positivo (VPP) de 62,5% e valor preditivo negativo (VPN) de 100%. A análise com Doppler mostrou sensibilidade de 88%, especificidade de 57,7%, VPP de 53,6% e VPN de 89,9%. Após a injeção do meio de contraste, esses valores passaram para: 92%, 46,6%, 48% e 91%, respectivamente. Os índices de resistividade foram significativamente mais altos em lesões malignas na análise com Doppler colorido ( < 0,001). Houve relação estatística significante entre a presença de vaso penetrante e malignidade ( < 0,001). A associação entre os critérios de classificação BI-RADS e Doppler colorido mostrou sensibilidade de 100%, especificidade de 86,6%, VPP de 80,7% e VPN de 100%. A associação entre BI-RADS e ultrassonografia contrastada resultou em sensibilidade de 100%, especificidade de 80%, VPP de 73,5% e VPN de 100%. A análise cinética subjetiva não conseguiu diferenciar entre nódulo benigno e maligno (tempo do início da contrastação = 0,816, tempo de clareamento da lesão = 0,622 e realce da lesão = 0,020). CONCLUSÃO: Os critérios adotados para o duplex-Doppler colorido associados ao BI-RADS fornecem os melhores resultados na distinção entre lesões benignas e malignas da mama. O estudo contrastado não acrescentou informações adicionais às análises prévias. / OBJECTIVE: The duplex-Doppler ultrasound and contrast enhanced ultrasound (CEUS) are poorly studied in breast lesions. However, in the other organs they have been proved to be useful in mass differentiation. Our objective is to characterize the Doppler findings before and after contrast agent injection in solid breast lesions then correlate them with pathological findings in order to evaluate the applicability of these methods in the differentiation of benign and malignant lesions. MATERIALS AND METHODS: Seventy solid breast masses were evaluated by conventional ultrasonography and duplex-color Doppler before and after injection of contrast medium (ultrasound contrast) in the period between March 2007 and January 2008 and their results were compared to histology (gold standard). All patients signed a consent form approved by the Ethics Committee of FMUSP. At gray-scale US the lesions were described and classified according to the BI-RADS lexicon. At duplex-Doppler we observed the lesion vascularity: avascular, hypovascular (one or two arteries) or hypervascular (three or more arteries); distribution (central or peripheral) and shape (regular or tortuous). If there was a penetrating artery, it was reported. We also observed resistive index. Based on literature data criterion was set up for classification which allowed to stratify breast lesions among probably benign (avascular or hypovascular masses, with regular vessels and peripheral distribution); probably malignant (hypervascular masses with tortuous and central vessels) or suspicious (any other combination of those factors). Kinetic analysis (wash in and wash out times, besides mass enhancement, in a subjective manner) and morphological analysis (using the same criteria of analysis with Doppler) were described in contrast study. RESULTS: Percutaneous biopsy revealed 25 malignant and 45 benign lesions. Morphologic analysis using gray-scale sonography and classified according the BI-RADS lexico showed sensitivity of 100% and specificity of 66.6%, positive and negative predictive values of 62.5% and 100% respectively. Doppler sonography, sensitivity, specificity, positive and negative predictive values were 88%; 57.7%; 53.6% and 89.9%. After contrast agent injection sensitivity, specificity, positive and negative predictive values changed to 92%; 46.6%; 48% and 91% respectively. The association among morphological and CDUS analysis findings resulted in a sensitivity of 100%, specificity of 86.6%, PPV 80.7% and NPV 100%. When morphological findings and CEUS analysis were associated values became 100% sensitivity, 80% specificity, 73.5% PPV, and 100% NPV. Resistive index was significantly higher ( < 0,001) in malignant lesions before and after contrast injection. Wash in and wash out times were similar for benign and malignant lesions (wash-in = 0,816, wash-out = 0,622 and intensity = 0,020). CONCLUSION: Duplex-Doppler criteria associated to BI-RADS classification proved to be the best combination to distinguish malignant lesions of the breast. CEUS evaluation did not provide additional information.
6

Avaliação das características vasculares dos nódulos sólidos de mama com ultrassonografia Doppler pré e pós-injeção de contraste por microbolhas / Evaluation of vascular characteristics of breast masses with Doppler ultrasound before and after microbubble contrast injection

Stanzani, Daniela 14 December 2010 (has links)
INTRODUÇÃO: O duplex-Doppler e a ultrassonografia com contraste são métodos pouco estudados em lesões mamárias. No entanto, em outros órgãos, têm se mostrado úteis na distinção entre lesões benignas e malignas. O objetivo deste trabalho é caracterizar os achados ao Doppler colorido pré e pós-contraste nos nódulos sólidos de mama, correlacionando-os com os resultados anatomopatológicos. MATERIAL E MÉTODOS: Setenta nódulos sólidos da mama foram avaliados por meio de ultrassonografia convencional e duplex-Doppler colorido antes e após a injeção do meio de contraste (ultrassonografia contrastada), no período compreendido entre março de 2007 e janeiro de 2008, e seus resultados foram comparados à análise histológica (padrão-ouro). Todas as pacientes assinaram o Termo de Consentimento Livre e Esclarecido, aprovado pelo Comitê de Ética da FMUSP. O estudo ultrassonográfico modo B avaliou a morfologia do nódulo e o classificou conforme o léxico BI-RADS. Ao duplex-Doppler colorido observou-se a vascularização nodular, descrevendo-se o número de vasos presentes (0 = avascularizado; 1 ou 2 = hipovascularizado, 3 = hipervascularizado), sua morfologia (regular ou tortuoso) e sua distribuição (periférica ou central). Os índices de resistividade e a presença de vaso penetrante também foram avaliados. A partir de dados da literatura criou-se um critério de classificação que permitiu estratificá-los entre provavelmente benigno (nódulos avasculares ou hipovasculares, com vasos regulares e distribuição periférica), provavelmente maligno (nódulos hipervasculares, com vasos tortuosos e distribuição central) ou suspeitos (qualquer outra associação desses fatores). No estudo contrastado foram realizadas análises cinética (avaliando-se os tempos de início da contrastação e do clareamento do nódulo, além da análise da intensidade da contrastação, de maneira subjetiva) e morfológica (utilizando-se os mesmos critérios da análise com Doppler). RESULTADOS: A análise histológica resultou em 25 lesões malignas e 45 lesões benignas. A classificação BI-RADS teve sensibilidade de 100%, especificidade de 66,6%, valor preditivo positivo (VPP) de 62,5% e valor preditivo negativo (VPN) de 100%. A análise com Doppler mostrou sensibilidade de 88%, especificidade de 57,7%, VPP de 53,6% e VPN de 89,9%. Após a injeção do meio de contraste, esses valores passaram para: 92%, 46,6%, 48% e 91%, respectivamente. Os índices de resistividade foram significativamente mais altos em lesões malignas na análise com Doppler colorido ( < 0,001). Houve relação estatística significante entre a presença de vaso penetrante e malignidade ( < 0,001). A associação entre os critérios de classificação BI-RADS e Doppler colorido mostrou sensibilidade de 100%, especificidade de 86,6%, VPP de 80,7% e VPN de 100%. A associação entre BI-RADS e ultrassonografia contrastada resultou em sensibilidade de 100%, especificidade de 80%, VPP de 73,5% e VPN de 100%. A análise cinética subjetiva não conseguiu diferenciar entre nódulo benigno e maligno (tempo do início da contrastação = 0,816, tempo de clareamento da lesão = 0,622 e realce da lesão = 0,020). CONCLUSÃO: Os critérios adotados para o duplex-Doppler colorido associados ao BI-RADS fornecem os melhores resultados na distinção entre lesões benignas e malignas da mama. O estudo contrastado não acrescentou informações adicionais às análises prévias. / OBJECTIVE: The duplex-Doppler ultrasound and contrast enhanced ultrasound (CEUS) are poorly studied in breast lesions. However, in the other organs they have been proved to be useful in mass differentiation. Our objective is to characterize the Doppler findings before and after contrast agent injection in solid breast lesions then correlate them with pathological findings in order to evaluate the applicability of these methods in the differentiation of benign and malignant lesions. MATERIALS AND METHODS: Seventy solid breast masses were evaluated by conventional ultrasonography and duplex-color Doppler before and after injection of contrast medium (ultrasound contrast) in the period between March 2007 and January 2008 and their results were compared to histology (gold standard). All patients signed a consent form approved by the Ethics Committee of FMUSP. At gray-scale US the lesions were described and classified according to the BI-RADS lexicon. At duplex-Doppler we observed the lesion vascularity: avascular, hypovascular (one or two arteries) or hypervascular (three or more arteries); distribution (central or peripheral) and shape (regular or tortuous). If there was a penetrating artery, it was reported. We also observed resistive index. Based on literature data criterion was set up for classification which allowed to stratify breast lesions among probably benign (avascular or hypovascular masses, with regular vessels and peripheral distribution); probably malignant (hypervascular masses with tortuous and central vessels) or suspicious (any other combination of those factors). Kinetic analysis (wash in and wash out times, besides mass enhancement, in a subjective manner) and morphological analysis (using the same criteria of analysis with Doppler) were described in contrast study. RESULTS: Percutaneous biopsy revealed 25 malignant and 45 benign lesions. Morphologic analysis using gray-scale sonography and classified according the BI-RADS lexico showed sensitivity of 100% and specificity of 66.6%, positive and negative predictive values of 62.5% and 100% respectively. Doppler sonography, sensitivity, specificity, positive and negative predictive values were 88%; 57.7%; 53.6% and 89.9%. After contrast agent injection sensitivity, specificity, positive and negative predictive values changed to 92%; 46.6%; 48% and 91% respectively. The association among morphological and CDUS analysis findings resulted in a sensitivity of 100%, specificity of 86.6%, PPV 80.7% and NPV 100%. When morphological findings and CEUS analysis were associated values became 100% sensitivity, 80% specificity, 73.5% PPV, and 100% NPV. Resistive index was significantly higher ( < 0,001) in malignant lesions before and after contrast injection. Wash in and wash out times were similar for benign and malignant lesions (wash-in = 0,816, wash-out = 0,622 and intensity = 0,020). CONCLUSION: Duplex-Doppler criteria associated to BI-RADS classification proved to be the best combination to distinguish malignant lesions of the breast. CEUS evaluation did not provide additional information.

Page generated in 0.0352 seconds