Ultrassonografia mamária: concordância entre exames realizados externamente e dentro de um centro especializado em radiologia mamáriaPONTUAL, Mariana Vila Nova de Oliveira 13 March 2017 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-08-31T20:05:01Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Mariana Vila Nova de Oliveira Pontual.pdf: 2162165 bytes, checksum: 9f86b45a02e8daa98d511dca09819553 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-17T21:27:45Z (GMT) No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Mariana Vila Nova de Oliveira Pontual.pdf: 2162165 bytes, checksum: 9f86b45a02e8daa98d511dca09819553 (MD5) / Made available in DSpace on 2018-09-17T21:27:45Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
DISSERTAÇÃO Mariana Vila Nova de Oliveira Pontual.pdf: 2162165 bytes, checksum: 9f86b45a02e8daa98d511dca09819553 (MD5)
Previous issue date: 2017-03-13 / A USG é um método diagnóstico consolidado na avaliação de nódulos mamários benignos e malignos. A concordância interobservador na descrição dos nódulos é um problema relacionado ao seu uso. O sistema BI-RADSᵀᴹ foi criado no intuito de uniformizar os relatórios e sugerir conduta. A experiência do examinador em radiologia mamária influencia a qualidade do exame e a concordância interobservador. Os objetivos principais foram a análise da concordância interobservador na descrição de nódulos sólidos mamários, a frequência do uso do BI-RADSᵀᴹ, e a avaliação de medidas de eficácia dos exames comparando-se exames realizados externamente (exame externo) e dentro de um centro especializado em radiologia mamária (exame interno). Foram comparadas USGs de 62 pacientes. Calculou-se o coeficiente de kappa quando o mesmo nódulo foi descrito em ambos os exames (n=49) para os descritores ecogenicidade e margens e também calculou-se este mesmo coeficiente quando ambos os exames expressaram a classificação BI-RADSᵀᴹ (n=44). Em 48 casos foi realizada biópsia e analisados VPP, VPN, sensibilidade e especificidade dos exames externo e interno levando em consideração os critérios de margem circunscrita e não-circunscrita. O uso da classificação BI-RADSᵀᴹ foi mais frequente nos exames internos. A concordância entre os exames externo e interno foi leve para ecogenicidade (k = 0,39) e para a classificação BI-RADSᵀᴹ (k = 0,40), confirmando as limitações do método já observadas na literatura. Houve concordância substancial para o descritor margens (k = 0,69), para nódulos hipoecogênicos (k = 0,62) e para a categoria B5 (k = 0,64). Observou-se grande percentual de nódulos B3 que foram submetidos à biópsia nos exames externos e internos, contrariando a recomendação teórica para esta categoria. Entre os exames internos, observou-se maior sensibilidade, especificidade, bem como maior valor preditivo positivo e negativo, quando comparados aos exames externos. / Ultrasound (US) is a consolidated diagnostic method in the evaluation of benign and malignant mammary nodules. Interobserver agreement in the description of nodules is a problem related to its use. The BI-RADSᵀᴹ system was designed to standardize reporting and suggest conduct. The examiner's experience in breast radiology influences the quality of the examination and interobserver agreement. The main objectives were the analysis of the interobserver agreement in the description of solid breast nodules at US, the frequency of BI-RADSᵀᴹ use, and the evaluation of measures of efficacy of the tests comparing externally performed examinations (external examination) and USs performed within a specialized center in breast radiology (internal examination). USGs of 62 patients were compared. The kappa coefficient was calculated when the same nodule was described in both exams (n = 49) for the descriptors echogenicity and margins and the same coefficient was also calculated when both exams expressed the BI-RADSᵀᴹ classification (n = 44). In 48 cases, biopsies were performed and PPV, NPV, sensitivity and specificity of the external and internal exams were analyzed using the circumscribed and non-circumscribed margin criteria. The use of the BI-RADSᵀᴹ classification was more frequent in internal examinations. The concordance between external and internal examinations was mild for echogenicity (k = 0.39) and for the BI-RADSᵀᴹ classification (k = 0.40), confirming the limitations of the method already observed in the literature. There was substantial agreement for the descriptor margins (k = 0.69), for hypoechogenic nodules (k = 0.62) and for category B5 (k = 0.64). It was observed a large percentage of B3 nodules that were submitted to biopsy, contrary to the theoretical recommendation for this category. Internal examinations demonstrated greater sensitivity, specificity and greater positive and negative predictive value when compared to the external examinations.
|
2 |
A confiabilidade da ultrassonografia tridimensional na avaliação de parâmetros morfológicos e biométricos do assoalho pélvico de mulheres com dor pélvica crônica e dispareunia / The reliability of three-dimensional ultrasonography in the evaluation of morphological and biometric parameters of the pelvic floor of women with chronic pelvic pain and dyspareuniaCarmo, Maria Aparecida Mazzutti Verlangieri 25 March 2019 (has links)
Introdução- A dor pélvica crônica é patologia debilitante em mulheres em idade reprodutiva, considerada problema de saúde pública, responsável por gasto anual nos EUA acima de 5 bilhões de dólares com diagnóstico desconhecido em cerca de 60% dos casos e se associa a dispareunia em 50% dos casos. E fundamental a obtenção de métodos diagnósticos dessa patologia. A ultrassonografia tridimensional vem se mostrando método de confiabilidade para avaliação do assoalho pélvico. ObjetivoAvaliar as lesões do músculo levantador do ânus (MLA) e a confiabilidade inter e intraobservador da biometria do assoalho pélvico pela ultrassonografia 3D em mulheres com dor pélvica crônica e dispareunia. Métodos- O estudo incluiu 49 pacientes com dor pélvica crônica e dispareunia no HCFMRP-USP. A aquisição dos blocos de ultrassonografia 3D foi realizada por dois examinadores de forma independente e \"cegados\", via transperineal utilizando a sonda RIC5-9D. Foram coletados três blocos por paciente (total 147) que foram analisados pelo examinador A (estudo intraobservador) e pelos examinadores A e B (estudo interobservador). A análise das medidas intraobservador foi realizada em dois tempos com intervalo de 90 dias. Os seguintes parâmetros foram avaliados: diâmetro transverso do hiato, diâmetro ânteroposterior do hiato, área hiatal, espessura do MLA às 3 e 9 h, as distâncias entre o músculo levantador do ânus e a uretra (DMLU) direita (D) e esquerda (E) e calculados os coeficientes de correlação intraclasse (CCI) e o coeficiente de correlação de concordância (CCC). Os gráficos correlação e de Bland e Altmann com seus limites de concordância (LC) foram elaborados. Adicionalmente os examinadores avaliaram as lesões do MLA através de sistema de score. Resultados - Na análise intraobservador os melhores parâmetros foram o diâmetro ântero-posterior (CCC 0,98; CCI 0,99 e LC 4,5%), a área hiatal Omni-VCI (CCC 0,99; CCI 0,98 e LC 3,8%) e área hiatal render (CCC 0,99; CCI 0,99 e LC 5,4%). Os parâmetros menos reprodutíveis foram a espessura do MLA às 3 h (CCC 0,58, CCI 0,90 e LC 28,2%) e 9 h (CCC 0,53, CCI 0,93 e LC 29,7%). Na análise interobservador os melhores parâmetros foram o diâmetro ântero-posterior (CCC 0,96; CCI 0,97 e LC 5,4) e a área hiatal Omni-VCI (CCC 0,97; CCI 0,97 e LC 8,9%). Os piores parâmetros foram espessura do MLA às 3 h (CCC 0,30; CCI 0,34 e LC de 38,2%) e às 9 h (CCC 0,32; CCI 0,32 e LC 35,1%). Tais achados foram reforçados pelos gráficos de Bland and Altman e de correlação. As lesões do levantador do ânus foram observadas em 10,2% (5/49) com excelente concordância. Conclusão - A avaliação do assoalho pélvico pela ultrassonografia transperineal em pacientes com dor pélvica crônica e dispareunia foi reproduzível através das análises morfológicas das lesões, do estudo biométrico intra ou interobservador para o diâmetro ântero-posterior, área hiatal render e Omni-VCI. Entretanto as medidas do diâmetro transverso do hiato, a espessura do MLA, o DMLU e a distância uretra ânus não são recomendadas para uso clínico devendo estar restritos à pesquisa / Introduction: Chronic pelvic pain is a debilitating condition in women of childbearing age, considered a public health problem, responsible for annual US spending of over US $ 5 billion, with an unknown diagnosis in about 60% of the cases and is associated with dyspareunia in 50% of cases. It is fundamental to obtain diagnostic methods for this pathology. Three-dimensional ultrasonography has shown to be a reliable method for evaluation of the pelvic floor. Objective: to assess levator ani muscle (LAM) injury and intra/interobserver reliability of pelvic floor biometry by 3D ultrasound in women with chronic pelvic pain and dyspareunia. Methods: The study included 49 women with pelvic pain and dyspareunia of the HCFMRP-USP. Two examiners performed the acquisition of 3D ultrasound via transperineal using the probe RIC5-9D independently and blindly. There were collected three blocks per patient (total 147) that were analyzed by the observer A (intraobserver study) and A and B (interobserver study). The analysis of the intraobserver measurements was performed in two times with 90 days apart. The following parameters were evaluated: the hiatal transverse diameter, hiatal anteroposterior diameter, hiatal area, thickness of the LAM at the 3 h and 9 h positions and right and left levator-urethra gap (LUG) measurements and calculated the intra-class correlation coefficient (ICC) and concordance correlation coefficient (CCC). Plots of correlation and Bland and Altmann with the limits of agreement (LoA) were constructed. Additionally, the observers evaluated the LAM injury using a score system. Results: In the intraobserver analisys the best parameters were the anteroposterior diameter (CCC 0.98; ICC 0.99 and LoA 4.5%), the hiatal area Omni-VCI (CCC 0.99; ICC 0.98 and LoA 3,8%) and hiatal area render (CCC 0.99; ICC 0.99 and LC 5.4%). The least reproducible parameters were the LAM thickness at 3 h (CCC 0.58, ICC 0.90 and LC 28.2%) and 9 h (CCC 0.53, ICC 0.93 and LC 29.7%). In relation to the interobserver analysis the best parameters were the anteroposterior diameter (CCC 0.96; ICC 0.97 and LoA 5.4) and the hiatal area Omni-VCI (CCC 0.97; ICC 0.97 and LC 8.9%). The worst results were LAM thickness at 3 h (CCC 0.30; ICC 0.34 and LC de 38.2%) and at 9 h (CCC 0.32; ICC 0.32 and LC 35.1%). Such findings were enforced by Bland and Altman and correlation plots. The LAM injuries were observed in 10.2% (5/49) with excellent concordance. Conclusions: The assessment of pelvic floor by transperineal ultrasound in patients with chronic pelvic pain and dyspareunia was reproducible either by morphology of LAM injuries or by biometric study, using intra or interobserver analysis for the anteroposterior diameter, hiatal area render and Omni-VCI. However, the measurements for the hiatal transverse diameter, levator ani thickness, right and left LUG and urethra-anus distance are not recommended for clinical use and it should be restricted for research purpose
|
3 |
Caracterização de lesões em imagens digitais de ultrassonografia e elastografia da mama utilizando técnicas inteligentes / Characterization of lesions in ultrasound and elastography images using machine learning methodsMarcomini, Karem Daiane 30 October 2017 (has links)
Muitos procedimentos vêm sendo desenvolvidos para auxiliar no diagnóstico precoce do câncer de mama. Devido a subjetividade na interpretação de imagens, os sistemas de diagnóstico auxiliado por computador (CADx) têm oferecido ao especialista uma segunda opinião mais precisa e confiável. Nesse propósito, essa pesquisa apresenta uma metodologia de investigação da potencialidade diagnóstica de um sistema computacional na classificação de achados suspeitos em imagens de ultrassom modo-B e de elastografia da mama. A base de dados foi constituída por 31 lesões malignas e 52 benignas e um conjunto adicional contendo 206 lesões de ultrassom modo-B (144 benignas e 62 malignas) para a realização dos testes de aprendizado de máquina. O contorno foi determinado automaticamente e através do delineamento manual de três radiologistas sob a imagem de ultrassom modo-B e, em seguida, mapeado na imagem elastográfica. As lesões foram classificadas pelo sistema CADx desenvolvido para ultrassom modo-B e elastografia do tipo strain. Os dados foram avaliados por meio da sensibilidade, especificidade e AUC. O sistema CADx desenvolvido proporcionou equivalência diagnóstica para a classificação das lesões a partir das diversas formas de determinação do contorno (manual e automática), permitindo a redução da variabilidade. Além disso, o sistema apontou resultados superiores à análise visual do radiologista que, quando considerado o resultado fornecido pela associação entre as imagens de ultrassom modo-B e elastografia, proporcionou um aumento comparativo de cerca de 7% em sensibilidade e 17,2% em especificidade nos testes com o sistema CADx usando o contorno feito pelo radiologista mais experiente. Além disso, constatou-se uma influência positiva no uso da ferramenta computacional pelos radiologistas, pois, na média, seus índices de sensibilidade e especificidade diagnóstica aumentaram também em relação à situação de análise convencional, passando de 87,1% e 55,8% para 90,3% e 73,1%, respectivamente. / Many procedures have been developed to aid in the early detection and diagnosis of breast cancer. In this context, Computer-Aided Diagnosis (CADx) systems were designed to provide to the specialist a reliable second opinion. This study presents the proposal of investigating the diagnostic ability of a computational system in the characterization of suspicious findings in B-mode ultrasound and breast elastography imaging. The database consisted of 31 malignant and 52 benign lesions and an additional data set containing 206 lesions (144 benign and 62 malignant) seen only on the B-mode ultrasound for performing the machine learning tests. Three radiologists drew manually the contour of the lesions in B-mode ultrasound and we used an automatic technique to segment the lesions. Then, the contour was mapped in the elastography image. The lesions were classified using the CADx system developed for B-mode ultrasound and strain elastography. We calculated the sensitivity, specificity and AUC to evaluate the data. The developed CADx system provided a diagnostic concordance in the classification of breast lesions from the different ways of contour determination (manual and automatic), allowing to reduce the diagnostic variability. In addition, the CADx system showed superior results to the visual analysis of the radiologist. When the radiologist associated both examinations (B-mode ultrasound and elastography), his visual analysis provided 87.10%, 55.77% and 0.714 of sensitivity, specificity and AUC, respectively. When we considered the result provided by the association between B-mode ultrasound and elastography images, the CADx system provided a comparative increase of about 7% of sensitivity and 17.2% of specificity, using the contour delimited by the most experienced radiologist. In addition, a positive influence was observed in the use of the computational tool by radiologists, since, on average, their sensitivity and specificity indexes also increased in relation to the conventional analysis, from 87.1% and 55.8% to 90.3% and 73.1%, respectively.
|
4 |
Caracterização de lesões em imagens digitais de ultrassonografia e elastografia da mama utilizando técnicas inteligentes / Characterization of lesions in ultrasound and elastography images using machine learning methodsKarem Daiane Marcomini 30 October 2017 (has links)
Muitos procedimentos vêm sendo desenvolvidos para auxiliar no diagnóstico precoce do câncer de mama. Devido a subjetividade na interpretação de imagens, os sistemas de diagnóstico auxiliado por computador (CADx) têm oferecido ao especialista uma segunda opinião mais precisa e confiável. Nesse propósito, essa pesquisa apresenta uma metodologia de investigação da potencialidade diagnóstica de um sistema computacional na classificação de achados suspeitos em imagens de ultrassom modo-B e de elastografia da mama. A base de dados foi constituída por 31 lesões malignas e 52 benignas e um conjunto adicional contendo 206 lesões de ultrassom modo-B (144 benignas e 62 malignas) para a realização dos testes de aprendizado de máquina. O contorno foi determinado automaticamente e através do delineamento manual de três radiologistas sob a imagem de ultrassom modo-B e, em seguida, mapeado na imagem elastográfica. As lesões foram classificadas pelo sistema CADx desenvolvido para ultrassom modo-B e elastografia do tipo strain. Os dados foram avaliados por meio da sensibilidade, especificidade e AUC. O sistema CADx desenvolvido proporcionou equivalência diagnóstica para a classificação das lesões a partir das diversas formas de determinação do contorno (manual e automática), permitindo a redução da variabilidade. Além disso, o sistema apontou resultados superiores à análise visual do radiologista que, quando considerado o resultado fornecido pela associação entre as imagens de ultrassom modo-B e elastografia, proporcionou um aumento comparativo de cerca de 7% em sensibilidade e 17,2% em especificidade nos testes com o sistema CADx usando o contorno feito pelo radiologista mais experiente. Além disso, constatou-se uma influência positiva no uso da ferramenta computacional pelos radiologistas, pois, na média, seus índices de sensibilidade e especificidade diagnóstica aumentaram também em relação à situação de análise convencional, passando de 87,1% e 55,8% para 90,3% e 73,1%, respectivamente. / Many procedures have been developed to aid in the early detection and diagnosis of breast cancer. In this context, Computer-Aided Diagnosis (CADx) systems were designed to provide to the specialist a reliable second opinion. This study presents the proposal of investigating the diagnostic ability of a computational system in the characterization of suspicious findings in B-mode ultrasound and breast elastography imaging. The database consisted of 31 malignant and 52 benign lesions and an additional data set containing 206 lesions (144 benign and 62 malignant) seen only on the B-mode ultrasound for performing the machine learning tests. Three radiologists drew manually the contour of the lesions in B-mode ultrasound and we used an automatic technique to segment the lesions. Then, the contour was mapped in the elastography image. The lesions were classified using the CADx system developed for B-mode ultrasound and strain elastography. We calculated the sensitivity, specificity and AUC to evaluate the data. The developed CADx system provided a diagnostic concordance in the classification of breast lesions from the different ways of contour determination (manual and automatic), allowing to reduce the diagnostic variability. In addition, the CADx system showed superior results to the visual analysis of the radiologist. When the radiologist associated both examinations (B-mode ultrasound and elastography), his visual analysis provided 87.10%, 55.77% and 0.714 of sensitivity, specificity and AUC, respectively. When we considered the result provided by the association between B-mode ultrasound and elastography images, the CADx system provided a comparative increase of about 7% of sensitivity and 17.2% of specificity, using the contour delimited by the most experienced radiologist. In addition, a positive influence was observed in the use of the computational tool by radiologists, since, on average, their sensitivity and specificity indexes also increased in relation to the conventional analysis, from 87.1% and 55.8% to 90.3% and 73.1%, respectively.
|