• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 299
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • Tagged with
  • 302
  • 302
  • 154
  • 26
  • 26
  • 26
  • 26
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Avaliação do campo acústico gerado pelos aparelhos de ultra-som terapêutico do programa de pós-graduação interunidades em bioengenharia, de acordo com a norma NBR-IEC 1689 / Evaluation of the acoustic field produced by the therapeutic ultrasound apparatus of Interunits Postgraduate Program in Bioengineering according with NBR-IEC 1689

Valentini, Elton Antonio 13 March 2006 (has links)
O uso do ultra-som na área da saúde é bastante amplo, tanto para o diagnóstico por imagem como para o tratamento de inúmeras afecções (de feridas de pele a tumores malignos). No Programa de Pós-Graduação Interunidades em Bioengenharia há mais de 20 anos são feitas pesquisas sobre a interação do ultra-som com os tecidos biológicos. O presente trabalho objetiva avaliar os campos acústicos gerados pelos aparelhos de ultra-som terapêutico usados no Programa de Pós Graduação Interunidades em Bioengenharia de acordo com a norma NBR-IEC 1689. Para isto foi montado um tanque acústico e um sistema de posicionamento para a avaliação dos aparelhos, bem como foi desenvolvido um software para controle e automação do sistema. Os parâmetros que a norma pede que sejam avaliados e seu respectivo intervalo de tolerância são: potência de saída ('+ OU -' 20%); área de radiação efetiva ('+ OU -' 20%); intensidade efetiva ('+ OU -' 20%); freqüência de trabalho acústica ('+ OU -' 10%); relação de não-uniformidade do feixe ('+ OU -' 30%); intensidade máxima do feixe; tipo de feixe; fator de operação; forma de onda de modulação. Foram avaliados 8 aparelhos, sendo que 3 deles usados no ambulatório da bioengenharia e 5 usados em pesquisa. Para se avaliar os parâmetros dos equipamentos é necessário que eles estejam declarados no equipamento ou em manual que acompanha o equipamento. Na falta destas especificações fez se necessário a proposta de valores de referência para os aparelhos de ultra-som terapêutico da bioengenharia / The use of the ultrasound is quite wide health area, so much for image diagnosis as for the treatment of countless disease (skin wounds to malignant tumors). In the Interunidades Program of Masters degree in Bioengineering during more than 20 years are made researches about the interaction of the ultrasound with the biological tissues. The present work objective is the evaluate the acoustic fields generated by therapeutic ultrasound apparatus used in the Interunidades Program of Masters degree in Bioengineering according with NBR-IEC 1689. In this way, it was set up an acoustic tank and a positioning system for the apparatus, as well as software was developed for control and automation of the system. Parameters required by standard to be measured are presented with the respective tolerance interval: declared potency ('+ OR -' 20%); effective radiation area ('+ OR -' 20%); effective intensity ('+ OR -' 20%); work acoustics frequency ('+ OR -' 10%); non uniformity of the field relationship ('+ OR -' 30%); maximum intensity of the field; field type; operation factor; modulation wave form. There were appraised 8 apparatus, 3 of them are used in clinic of bioengineering and 5 are used in research. To evaluate the equipment parameters it is necessary that they are declared in the equipment or in equipment manual. In the lack of these specifications it is necessary proposal of reference values for the therapeutic ultrasound apparatus of bioengineering
202

Desenvolvimento de medidor de vazão de gás por ultra-som : modelagem, protótipo e testes

Ramos, Rodrigo 14 December 2006 (has links)
Made available in DSpace on 2016-12-23T14:08:13Z (GMT). No. of bitstreams: 1 Dissertacao de Rodrigo Ramos.pdf: 1546367 bytes, checksum: d9dd7667fd9e6d0f4d87e3b238a29764 (MD5) Previous issue date: 2006-12-14 / The use of transit time ultrasonic flow measurement technique has increased very quickly in the last years, so that it is urgently necessary to develop Brazilian technology in this instrumentation field. This work presents the development of a transit time flow meter prototype, called MEVUS, devoted to measurement of gas flows. It presents the mathematical modeling of the governing physical process of the interaction between the ultrasonic wave and the flow that one wants to measure, which is supposed completely developed in a circular pipe. It also presents a systematization of the uncertainty analysis related to the measurement process. The process of conception, analysis and design of the prototype is equally described, so that the reader can easily understand the problems found during the development, highlighting the proposed solutions and the feedback of the creation process of MEVUS Medidor de Vazão por Ultra-Som (Ultrasonic Flowmeter). Performance tests were conducted in the Flow Machines Laboratory of the Mechanical Engineering Department UFES. They are clearly described. The conclusions are presented, as well as the suggestions for future works / A medição ultra-sônica por tempo de trânsito vem alargando velozmente seu campo de aplicação nos últimos anos, havendo, sem dúvida, a necessidade urgente de desenvolvimento de tecnologia brasileira neste campo da instrumentação. O trabalho apresenta o desenvolvimento de um protótipo, batizado de MEVUS, para medidor de vazão ultra-sônico por tempo de trânsito voltado à medição de vazão de gás. Desenvolve-se a modelagem matemática do processo físico que governa a interação entre a onda ultra-sônica e o escoamento que se deseja medir, o qual se supõe plenamente desenvolvido numa tubulação circular. Apresenta-se também a sistematização da análise de incertezas. O processo de concepção, análise e projeto do protótipo é igualmente descrito, permitindo ao leitor a compreensão dos desafios enfrentados durante as atividades, destacando as soluções propostas e realimentação do processo de desenvolvimento do MEVUS Medidor de Vazão por Ultra-Som. Os testes preliminares de desempenho conduzidos no Laboratório de Máquinas de Fluxo do departamento de Engenharia Mecânica UFES são claramente descritos, apresentando-se as conclusões e as sugestões de trabalhos futuros
203

Utilização do exercício físico versus ultra-som pulsado de baixa intensidade na manutenção de massa óssea / Study of low-intensity pulsed ultrasound and of the physical exercise effect post-ovariectomy bone mass maintenance in an animal model

Lourdes Cristina de Albuquerque Haach 22 June 2006 (has links)
O ultra-som pulsado de baixa intensidade é uma onda mecânica com efeitos osteogênicos promisso- res para o tratamento da osteoporose. Baseada neste efeito, a pesquisa tem como objetivo a identificação das mudanças causadas pela aplicação do ultra-som em ossos osteopênicos e a comparação com as mudanças causadas pelos exercícios físicos. Aplicou-se o protocolo experimental em um modelo animal de ratos fêmeas maduras ovariectomizadas. Utilizaram-se 35 ratos fêmeas, divididas em 5 grupos: ovariectomia controle (OVX), pseudo ovariectomia (PSEUDO-OVX), ovariectomia tratado com ultra-som (US), ovariectomia treinado com caminhada (CAMINHADA) e ovariectomia treinado com exercício resistido (SALTO). O protocolo de tratamento estendeu-se por 12 semanas, com aplicação ultra-sônica diária de 20 minutos (seis vezes por semana) e realização de exercício três vezes por semana, sendo 40 minutos para CAMINHADA e três séries de 10 exercícios para o SALTO. Para a identificação dos efeitos do tratamento de ultra-som e dos exercícios em ratos fêmeas osteopênicas utilizaram-se os seguintes parâmetros: massa corporal, dosagem de fosfatase alcalina, área trabecular, histomorfometria e valor de microdureza Vickers. Conclui-se que os três tipos de tratamento executados exerceram um efeito preventivo na perda de massa óssea pós-ovariectomia quando comparados ao OVX, mas não foram capazes de alcançar os valores encontrados no PSEUDO-OVX para os parâmetros analisados. As avaliações da quantidade óssea indicaram que o tratamento mais efetivo foi o SALTO para este parâmetro. Os resultados do US e CAMINHADA foram semelhantes nos parâmetros analisados / The low intensity pulsed ultra-sound is a mechanical wave with promising osteogenics effects for the osteoporosis treatment. Based in these effects, the research aims the identification of changes caused by ultra-sound application and physical exercises in osteopenics bones; and if there are similarity between them. Thus, it was applied an experimental protocol in an animal model of mature ovariectomized rats. It was used 35 rats, divided in 5 groups: control ovariectomized (OVX), pseudo ovariectomized (PSEUDO-OVX), ovariectomized with ultra-sound treatment (US), ovariectomized trained with walk (CAMINHADA) and ovariectomized trained with resisted exercise (SALTO). The protocol of treatment lasted 12 weeks, with the application of ultra-sound daily for 20 minutes (six times per week) and the realization of exercises three times per week, with 40 minutes for CAMINHADA and three sets of 10 exercises for SALTO. It was used the followed parameters to identify the effects of the ultra-sound treatment and the exercises in osteopenic rats: body mass, alkaline phosphatasis dosage, trabecular area, histomorphometry and Vickers microhardness value. The results showed that the three types of applied treatments have a preventive effect in the loss of bone mass after ovariectomy when compared with OVX. However, they could not reach the found values in PSEUDO-OVX for the analysed parameters. The evaluations of bone quantity indicated that the most effective treatment was SALTO for this parameter. The results of US and CAMINHADA were similar in evaluated parameters
204

Técnicas de propagação de ondas na estimativa de propriedades mecânicas de painéis OSB / Wave propagation techniques in estimation of mechanical properties of OSB panels

Elen Aparecida Martines Morales 30 October 2006 (has links)
Um dos painéis derivados de madeira que tem se destacado é o OSB (Oriented Strand Board). Cada vez mais se evidencia a necessidade de novas tecnologias relacionadas à avaliação das propriedades mecânicas desse tipo de derivado de madeira, atualmente realizada através de ensaios destrutivos, efetuados horas ou dias após a respectiva produção. A utilização de métodos não-destrutivos tem se mostrado eficiente na caracterização mecânica e na avaliação da qualidade da madeira, e promissora em relação aos derivados de madeira. O objetivo geral deste trabalho foi investigar a eficiência de técnicas não-destrutivas de ensaio, de ultra-som e de stress wave, na estimativa de parâmetros físicos e mecânicos de painéis OSB fabricados no país. Foram considerados dois grupos, com 10 painéis de espessuras nominais de 15mm cada, que possuíam valores de resistência e de módulos de elasticidade na flexão estática, na direção longitudinal, distintos entre si. Primeiramente foram conduzidos os ensaios não-destrutivos, de ultra-som e de stress wave, nos painéis OSB e, em seguida, os ensaios destrutivos para a caracterização físico-mecânica e subseqüentes comparações. Os painéis estudados apresentaram valores de velocidades e constantes dinâmicas diferenciados na espessura e nas direções longitudinal e transversal. Os coeficientes de correlação obtidos entre os valores de velocidades e de constantes dinâmicas e os das propriedades físico-mecânicas, dos dois grupos de painéis, na espessura e direção transversal, não atingiram 0,70 e, na direção longitudinal superaram 0,90. Mostrou-se que é equivalente a estimativa de parâmetros mecânicos na flexão estática, ou até mesmo o estudo de painéis OSB, com a utilização dos métodos não-destrutivos de ultra-som e de stress wave. Com os resultados obtidos são gerados importantes subsídios para possibilitar a avaliação da produção de painéis OSB, viabilizando eventuais correções e ajustes até no decorrer do próprio processo produtivo. / Wood based materials production has grown in the national market, as it is the current international trend. Such products have been an interesting alternative to the sawn wood. Among them, OSB (Oriented Strand Board) has been of an outstanding importance. Its potential of production in the national context is expressive when supplying civil construction, furniture industry, and others. However, this fact also makes clear the need of innovative technologies for mechanical properties evaluation of this wood based material, since until the present day it has been conducted with destructive tests which are only made hours or days after production. Nondestructive methods utilization has been proven to be efficient for mechanical characterization and quality evaluation of sawn wood, and quite promising for wood based materials. The main goal of this research has been to investigate the efficiency of nondestructive testing (ultrasound and stress wave) when estimating physical and mechanical parameters of OSB panels made in Brazil. Two groups of ten 15mm thick panels have been used, having each one of them strength and modulus of elasticity in static bending values distinct from each other in longitudinal direction. First the two types of nondestructive testing have been conducted on all OSB panels and then destructive tests have also been conducted for physical-mechanical characterization and following comparisons. Values of velocities and dynamic constants both in thickness and longitudinal and transversal directions have been different in the two groups of studied panels. Correlation coefficients between values of velocity and dynamic constants and values of physical-mechanical properties of the two groups of panels have not reached 0,70 in thickness and transversal direction, but they have exceeded 0,90 in longitudinal direction. It has been shown that ultrasound is analogous to stress wave either when estimating static bending mechanical parameters or studying OSB panels by nondestructive testing. Such results generate some important subsidies to the evaluation of OSB production, making feasible eventual corrections and adjustments even in the course of its process.
205

Efeitos do ultra-som terapêutico na integração de enxertos de pele total em coelhos. / Effects of the therapeutic ultrasound on the integration of full-thickness skin graft in rabbits.

Amancio, Adriana da Costa Gonçalves 20 February 2003 (has links)
O ultra-som terapêutico é um recurso físico muito empregado como coadjuvante na promoção do reparo tecidual. Neste trabalho, foi estudada a influência do ultra-som terapêutico na integração dos enxertos de pele total num modelo experimental em coelhos. Foram utilizados 20 coelhos adultos, fêmeas, nos quais foram realizadas cirurgias de enxerto autógeno de pele total nas regiões escapulares, pela ressecção de dois retalhos quadrados de pele de 2 cm de lado, invertendo sua posição, o enxerto retirado do lado direito sendo colocado na área receptora esquerda e vice-versa. O enxerto do lado direito era submetido ao tratamento efetivo com o ultra-som (3 MHz, 0,5 W/cm2, 5 minutos) e o enxerto do lado esquerdo, a tratamento placebo, iniciado no 3o dia pós-operatório e aplicado diariamente por sete dias. Os animais eram sacrificados no 11o dia pós-operatório e os enxertos, ressecados com uma margem de segurança, para análise histopatológica, com cortes de 5 µm. Foram obtidos cortes histológicos corados com técnicas específicas (Tricrômico de Gomori, PCNA e Picrosirius) e analisados ao microscópio de luz, sendo realizada a contagem das células em proliferação e dos vasos neoformados e a morfometria das áreas da epiderme e derme. Os resultados mostraram um significativo aumento no número de células em proliferação na epiderme e vasos neoformados na camada reticular da derme, mas isto não implicou em uma diferença entre as áreas da epiderme e derme, nos enxertos irradiados e não irradiados. Concluímos que o ultra-som terapêutico induz alterações morfológicas nos processos biológicos, como proliferação celular da camada germinativa da epiderme e neoangiogênese, envolvidos na integração de enxertos de pele total, com um potencial de aplicação clínica em humanos. / Therapeutic ultrasound is a widely used co-adjuvant physical mean to promote tissue repair. In the present investigation, the influence of therapeutic ultrasound on the integration of full-thickness skin graft was studied in rabbits. Twenty female adult rabbits were used, two 2x2 cm square-shaped full-thickness skin grafts being obtained from both scapular regions and swapped, the one cut out on the right being placed on the left and vice-versa. The graft on the right was effectively irradiated with the therapeutic ultrasound (3 MHz, 0,5 W/cm2, 5 minutes) for seven days beginning on the third postoperative day. The graft on the left was submitted to a sham irradiation. The animals were killed on the 11th day and the grafted areas were resected (graft + safety margin) for histologic examination by means of 5 µm-thick sections alternatively stained with Gomori's trichrome, PCNA and Picrosirius and examined on the light microscope. Eider proliferating cells and new blood vessels were counted, as well as the epidermic and dermic areas were measured. The results showed a significant increase in the number of epidermic proliferating cells and new blood vessels, but this did not imply any difference between the epidermic and dermic areas between irradiated and non-irradiated grafts. We conclude that the therapeutic ultrasound induces morphologic alterations in the biologic processes, as epidermic germinative layer cell proliferation and neo-angiogenesis, involved in the integration of full-thickness skin grafts and this has a potential for clinical use in humans.
206

Técnicas de propagação de ondas na estimativa de propriedades mecânicas de painéis OSB / Wave propagation techniques in estimation of mechanical properties of OSB panels

Morales, Elen Aparecida Martines 30 October 2006 (has links)
Um dos painéis derivados de madeira que tem se destacado é o OSB (Oriented Strand Board). Cada vez mais se evidencia a necessidade de novas tecnologias relacionadas à avaliação das propriedades mecânicas desse tipo de derivado de madeira, atualmente realizada através de ensaios destrutivos, efetuados horas ou dias após a respectiva produção. A utilização de métodos não-destrutivos tem se mostrado eficiente na caracterização mecânica e na avaliação da qualidade da madeira, e promissora em relação aos derivados de madeira. O objetivo geral deste trabalho foi investigar a eficiência de técnicas não-destrutivas de ensaio, de ultra-som e de stress wave, na estimativa de parâmetros físicos e mecânicos de painéis OSB fabricados no país. Foram considerados dois grupos, com 10 painéis de espessuras nominais de 15mm cada, que possuíam valores de resistência e de módulos de elasticidade na flexão estática, na direção longitudinal, distintos entre si. Primeiramente foram conduzidos os ensaios não-destrutivos, de ultra-som e de stress wave, nos painéis OSB e, em seguida, os ensaios destrutivos para a caracterização físico-mecânica e subseqüentes comparações. Os painéis estudados apresentaram valores de velocidades e constantes dinâmicas diferenciados na espessura e nas direções longitudinal e transversal. Os coeficientes de correlação obtidos entre os valores de velocidades e de constantes dinâmicas e os das propriedades físico-mecânicas, dos dois grupos de painéis, na espessura e direção transversal, não atingiram 0,70 e, na direção longitudinal superaram 0,90. Mostrou-se que é equivalente a estimativa de parâmetros mecânicos na flexão estática, ou até mesmo o estudo de painéis OSB, com a utilização dos métodos não-destrutivos de ultra-som e de stress wave. Com os resultados obtidos são gerados importantes subsídios para possibilitar a avaliação da produção de painéis OSB, viabilizando eventuais correções e ajustes até no decorrer do próprio processo produtivo. / Wood based materials production has grown in the national market, as it is the current international trend. Such products have been an interesting alternative to the sawn wood. Among them, OSB (Oriented Strand Board) has been of an outstanding importance. Its potential of production in the national context is expressive when supplying civil construction, furniture industry, and others. However, this fact also makes clear the need of innovative technologies for mechanical properties evaluation of this wood based material, since until the present day it has been conducted with destructive tests which are only made hours or days after production. Nondestructive methods utilization has been proven to be efficient for mechanical characterization and quality evaluation of sawn wood, and quite promising for wood based materials. The main goal of this research has been to investigate the efficiency of nondestructive testing (ultrasound and stress wave) when estimating physical and mechanical parameters of OSB panels made in Brazil. Two groups of ten 15mm thick panels have been used, having each one of them strength and modulus of elasticity in static bending values distinct from each other in longitudinal direction. First the two types of nondestructive testing have been conducted on all OSB panels and then destructive tests have also been conducted for physical-mechanical characterization and following comparisons. Values of velocities and dynamic constants both in thickness and longitudinal and transversal directions have been different in the two groups of studied panels. Correlation coefficients between values of velocity and dynamic constants and values of physical-mechanical properties of the two groups of panels have not reached 0,70 in thickness and transversal direction, but they have exceeded 0,90 in longitudinal direction. It has been shown that ultrasound is analogous to stress wave either when estimating static bending mechanical parameters or studying OSB panels by nondestructive testing. Such results generate some important subsidies to the evaluation of OSB production, making feasible eventual corrections and adjustments even in the course of its process.
207

Ação do ultra-som de baixa intensidade em ossos de ratas osteopênicas.

Carvalho, Daniela Cristina Leite de 11 May 2001 (has links)
Por ser a osteoporose um grande problema de saúde pública e sua ocorrência aumentar os índices de morbidade e mortalidade proporcionados por fraturas geradas pela maior fragilidade óssea é importante o estudo de novos tratamentos para este quadro clínico. Tratamentos alternativos são opções para pessoas com alto risco de desenvolver osteoporose mas que possuem restrições aos tratamentos convencionais já existentes. Assim, este estudo tem o objetivo de analisar a ação do ultra-som de baixa intensidade (30mW/cm 2, freqüência de repetição de 1 KHz e ciclo de trabalho de 20%), como método não invasivo, em modelo de ratas osteopênicas. O modelo experimental foi obtido através da realização de ovarectomia e histerectomia em ratas da raça Holstman, com aproximadamente 200 gramas. Para obtenção do quadro de osteopenia foram aguardados 30 dias. Os animais foram divididos dois grupos: grupo placebo e grupo tratado. O tratamento começou no 31º dia após o procedimento cirúrgico, com duração de 20 dias consecutivos por 20 minutos diários. No grupo placebo, as ratas não foram submetidas ao tratamento ultra-sônico mas foram submetidas ao mesmo estresse causado às do grupo tratado. A emissão do campo ultra-sônico, no grupo tratado, foi na região do colo de fêmur. As propriedades mecânicas da diáfise femoral não se alteraram nos ossos osteopênicos comparados com ossos normais, assim como também não se alteraram nos ossos tratados comparados com os não tratados. Os resultados quantitativos de cálcio e fósforo não mostraram diferenças significativas entre os grupos placebo e tratado. No entanto, os achados qualitativos obtidos através da microscopia eletrônica de varredura indicaram uma microarquitetura óssea mais preservada nos ossos do grupo tratado. / As osteoporosis has become a major public health problem and its occurrence increases the rates of morbidity and mortality caused by fractures originated from bone fragility, it is important to study new treatments for this disease. Alternative treatments are options for those people with increased risk of osteoporosis development but with restrictions for the ordinary treatments already existent. This study aims at analyzing the low intensity ultrasound action (30mW/cm2 , 200ms burst of 1.5 MHz sine waves repeated at 1.0kHz) as a non invasive method, in the osteopenic rat model. Mature Holstman rats were subjected to bilateral ovariectomy. In order to obtain osteopenic rats, a 30 day period was allowed. The animals were separated in 2 groups: non-treated and treated. The treatment began in the 31 st day after the surgery, lasting twenty days, 20 minutes/day, in the femural neck site. The non treated group was subjected to the same stress caused to the treated group. The bone mineral matrix content of the femural neck (calcium and phosphorus) showed no significant differences among the groups. However, the analyzes using scanning electron micrographs indicated the smaller microarchitectural deterioration of trabecular bone present in the treated rats groups.
208

Desempenho produtivo e características da carcaça de bovinos de diferentes grupos raciais, castrados e não-castrados / Productive performance and carcass characteristics of different castrated and non-castrated cattle breed groups

Vittori, Andréa 27 June 2003 (has links)
Submitted by Nathália Faria da Silva (nathaliafsilva.ufv@gmail.com) on 2017-07-07T19:48:04Z No. of bitstreams: 1 texto completo.pdf: 353154 bytes, checksum: 01838ba4224cc2670af448ab8f18fa20 (MD5) / Made available in DSpace on 2017-07-07T19:48:04Z (GMT). No. of bitstreams: 1 texto completo.pdf: 353154 bytes, checksum: 01838ba4224cc2670af448ab8f18fa20 (MD5) Previous issue date: 2003-06-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O experimento foi realizado na Estação Experimental de Zootecnia de Colina – Instituto de Zootecnia, Colina-SP e no Departamento de Zootecnia- UFV, Viçosa-MG. Foram utilizados 86 bovinos, castrados e inteiros, com peso médio de 329,45 kg (± 19,8 meses de idade) dos rebanhos Nelore-Seleção, Guzerá, Gir e Caracu, submetidos à seleção para peso aos 378 dias de idade (P378) e Nelore-Controle, no qual não se aplicou o processo de seleção, sendo 12 Gir, 20 Guzerá, 20 Nelore-Seleção e 20 Caracu e 14 Nelore-Controle. A dieta continha a relação volumoso (silagem de milho) : concentrado 60:40 na MS, com 14,8% de proteína bruta (PB, %MS). O delineamento experimental foi o inteiramente casualizado em esquema fatorial 5 x 2 (grupos genéticos e condições sexuais). Foram analisadas as características de desempenho, os dias de confinamento (DC) e a idade de abate (IA) dos animais; características físicas das carcaças, dos cortes primários e comerciais; as perdas por aparas e cozimento; a força de cisalhamento; a temperatura e o pH da carne e a composição química da seção HH. A acurácia da técnica do ultra-som em predizer os valores de espessura de gordura (EG, mm) e área de olho-de-lombo (AOL, cm 2 ) de bovinos de corte foi testada; e validação dos SVFR e do NRC de Gado de Corte - níveis 1 (Sistema NRC) e 2 (Sistema Cornell); para bovinos de corte, sob condições de confinamento, comparando-se o CMS e GMD preditos pelos sistemas com aqueles observados em condições experimentais. No desempenho, os animais castrados foram abatidos mais leve, com menor tempo de confinamento; os animais do grupo genético Caracu foram mais tardios na acumulação de gordura de cobertura, permanecendo mais tempo em confinamento. O programa de seleção para peso mostrou-se eficiente, pois os animais do grupo Nelore-Seleção foram abatidos mais pesados e com excelente ganho médio diário, porém com pior eficiência bionutricional quando comparado ao grupo Nelore-Controle. A condição sexual afetou as principais características físicas da carcaça: os animais não-castrados apresentaram carcaças mais pesadas, com maior rendimento, maior proporção de tecido muscular, com excelente acabamento de gordura de cobertura. Animais do grupo genético Caracu mostraram-se mais tardios, com maior deposição de tecido muscular e menor deposição de gordura, produziram uma maior proporção de ponta-de-agulha e menor proporção de traseiro especial quando comparado com os demais grupos genéticos, evidenciando a necessidade de melhoria destas características nos programas de melhoramento genético da raça. Os animais do grupo genético Nelore-Seleção produziram carcaças mais pesadas que o grupo Nelore-Controle, evidenciando melhoria do processo de seleção para peso ao qual foram submetidos. Os animais castrados tiveram maiores perdas de aparas do dianteiro quando comparados aos não-castrados. Não houve diferença entre no pH final da carcaça entre os grupos genéticos, porém os animais não-castrados tiveram valores mais elevados que os castrados, provavelmente pelo maior estresse no grupo dos não-castrados, mas o pH final ficou dentro da faixa considerada ótima para todas as carcaças estudadas. Não foram observadas diferenças na força de cisalhamento entre os grupos genéticos e entre condição sexual, considerando que raças zebuínas, se bem manejadas, são capazes de produzir carne macia, atendendo às exigências do mercado consumidor. Para os experimentos analisados, a técnica do ultra-som não foi eficaz em predizer os valores de espessura de gordura e área de olho-de-lombo. Entretanto, houve uma correlação maior da técnica para área de olho-de-lombo do que para espessura de gordura. Os sistemas NRC (1996), Cornell e Viçosa de Formulação de Rações não foram capazes de estimar com equivalência o CMS e GMD dos animais em confinamento, no Brasil central. A subestimava do GMD, em função do consumo de energia, pode ser devido ao ganho compensatório observado em animais confinados, após a fase de recria em pastagens, que não é levado em consideração nos programas avaliados. / This experiment was carried out at the Animal Science Colina Experimental Station, Institute of Animal Science, Colina- SP and Department of Animal Science-UFV, Viçosa-MG. A total of 86 castrated and non-castrated Nelore-Selecao (20), Guzera (20), Gir (12), and Caracu (14) bovines, with an average weight of 329.45 kg (± 19.8 months old) was submitted to weight selection at 378 days of age (P378) and Nelore-Control. The diet contained corn silage:concentrate (60:40) on a DM basis and 14.8% crude protein (CP, %MS). The experiment was arranged in a complete randomized 5 x 2 factorial scheme (genetic groups x sexual conditions). The performance characteristics, confinement days (CD) and age at slaughtering (AS) of the animals were analyzed as well as physical carcass characteristics of primary and commercial cuts; losses due to trimming and cooking; shear force, meat temperature and pH and HH section feed chemical composition. Ultra sound accuracy in predicting fat thickness values (FT, mm) and loin eye area (LEA, cm 2 ) of beef cattle was xitested; cattle. SVFR and NRC – levels 1 (System NRC) and 2 (System Cornell) were validated for beef cattle under feedlot conditions, by comparing the DMC and DAG predicted by the systems with those observed under experimental conditions. In the performance analysis, the animals were slaughtered with a lower weight and shorter feedlot time; the Caracu breed animals accumulated cover fat more slowly, remaining under confinement for a longer time. The weight selection program was shown to be efficient since the Nelore-Selection animals were slaughtered with a heavier weight and excellent daily average weight gain but with less bio-nutritional efficiency than the Nelore-Control group. Sexual condition affected the main physical characteristics of the carcass: the non-castrated animals presented heavier, lower carcass yield, higher muscular tissue proportion, and excellent cover fat finishing. Caracu breed animals had a slower growth, with more muscular tissue deposition and less fat deposition, producing a higher proportion of spare ribs and lower hind proportion than the other breed groups, characteristics that need to be improved through breeding programs. The Nelore-Selection breed animals produced heavier carcasses than the Nelore-Control group, showing improvement in the weight selection process to which they were submitted. The castrated animals had greater forequarter trimming losses than the non-castrated animals. No difference was found in the final pH of the carcass among the breed groups, but the values of the non- castrated animals were higher than those of the castrated ones, probably due to the greater stress experienced by the non-castrated animals; final pH was within the range considered optimal for all the carcasses studied. No difference in shearing force was found between the genetic groups and sexual conditions, considering that well- managed Zebu breeds are capable of producing tender meat, thus satisfying consumer demands. For the experiments analyzed, the ultra sound –technique was effective in predicting fat thickness and loin eye area- values. However, there was a higher technique correlation for the loin eye area than for fat thickness. The Ration Formulation Systems NRC (1996), Cornell and Viçosa, were not capable of estimating DMC and DAG of the feedlot animals in central Brazil. DAG underestimate, as a function of energy consumption, may be xiidue to the compensating gain observed in the feed-lot animals, after the growing phase at pasture which was not taken into account in the programs evaluated.
209

Estudo da classificação não-destrutiva de peças serradas de espécies cultivadas no Brasil para uso em estruturas. / Study of nondestructive classification of sawed parts of cultivated species in Brazil for use in structures

Candian, Marcela 02 February 2007 (has links)
Made available in DSpace on 2016-06-02T20:09:05Z (GMT). No. of bitstreams: 1 DissMC.pdf: 5176018 bytes, checksum: f426ba516c8cecc516100eda5321f84b (MD5) Previous issue date: 2007-02-02 / Universidade Federal de Minas Gerais / This research had for purpose comparatively to verify the accuracy of the techniques of transverse vibration and ultrasound to the values gotten in static testings, for sawed wood used in structures. With the results gotten in the development of the present research it was possible to calibrate the coefficient of modification (kmod, 3) of NBR 7190:1997, besides increasing the relative knowledge to the nondestructive tests in wood. In the experimental methodology studies with parts of structural members of Eucalyptus grandis, Eucalyptus citriodora, Pinus sp and Goupia glabra had been carried through, which had been classified using the techniques of ultrasound and transverse vibration, for the determination of the dynamic modulus of elasticity (Ed). Simultaneously to the tests with ultrasound they had been carried through the visual grading and tests of static bending (MOE). The values of coefficient of determination for the technique of transverse vibration (R² = 0,75, R² = 0,80, R² = 0,93 and R² = 0,89) and for the technique of ultrasound (R2 = 0,65, R2 = 0,76, R2 = 0,66 and R2 = 0,88), gotten respectively for the Eucalyptus grandis, Eucalyptus citriodora, Pinus sp and Goupia glabra are significant, demonstrating that the techniques of ultrasound and transverse vibration are important tools for nondestructive inference of the modulus of elasticity of wood. The technique of transverse vibration presented better resulted in relation to the ultrasound, therefore it presents one better tack enters the physical model of the phenomenon and the corresponding associated mathematical model. In the determination of the values of coefficient of modification kmod, 3, was verified that the technique of transverse vibration presented superior values of coefficient in relation the ultrasound technique, therefore allows a classification next to the values gotten in the static bending. / Este trabalho teve por finalidade verificar a acuracidade das técnicas de ultra-som e vibração transversal comparativamente aos valores obtidos em ensaios estáticos, para madeira serrada empregada em estruturas. Com os resultados obtidos no desenvolvimento deste trabalho foi possível calibrar o coeficiente de modificação (kmod,3) da NBR 7190:1997 - Projeto de Estruturas de Madeira, além de ampliar o conhecimento relativo aos ensaios não-destrutivos em madeira. Na metodologia experimental foram realizados estudos com peças de dimensão estrutural das espécies Eucalyptus grandis, Eucalyptus citriodora, Pinus sp e Goupia glabra, as quais foram classificadas mecanicamente utilizando as técnicas de ultra-som e vibração transversal, para a determinação do módulo de elasticidade dinâmico (Ed). Simultaneamente aos ensaios com ultra-som realizou-se a classificação visual das peças e ensaios de flexão estática (MOE). Os valores de coeficiente de determinação para a técnica de vibração transversal (R²= 0,75, R²= 0,80, R²= 0,93 e R²= 0,89) e para a técnica de ultra-som (R2 = 0,65, R2 = 0,76, R2 = 0,66 e R2 = 0,88), obtidos respectivamente para as espécies Eucalyptus grandis, Eucalyptus citriodora, Pinus sp e Goupia glabra, são significativos, demonstrando que as técnicas de ultra-som e vibração transversal são importantes ferramentas para inferência não-destrutiva do módulo de elasticidade da madeira. A técnica de vibração transversal apresentou melhores resultados em relação ao ultra-som, pois apresenta uma melhor aderência entre o modelo físico do fenômeno e o correspondente modelo matemático associado. Na determinação dos valores de coeficiente de modificação kmod,3, verificou-se que a técnica de vibração transversal apresentou valores superiores de coeficiente em relação a técnica de ultra-som, pois esta permite uma classificação mais próxima dos valores obtidos na flexão estática.
210

Transdutores ultra-sônicos piezoelétricos com difração limitada : simulação e construção.

Ruiz, Alina Beatriz Aulet 18 August 2006 (has links)
Made available in DSpace on 2016-06-02T20:15:17Z (GMT). No. of bitstreams: 1 TeseABAR.pdf: 4875221 bytes, checksum: a49cbab70eac041e5e297ea7d21bf2e2 (MD5) Previous issue date: 2006-08-18 / The importance of ultrasound limited-diffraction Bessel beams in medical images, tissue characterization, and estimation of Doppler speed (blood flow) as well as in many other areas of Physics has increased in the two last decades. In this work an alternative solution to produce a transducer of limiteddiffraction was implemented, with the polarization following the geometry of the Bessel's function. These transducers (also called Bessel Transducers) have been constructed using a ferroelectric ceramic PZT doped with Niobium, by means of a simple technique of polarization. The electrodes in the faces of ceramics were made with a silver painting in form of three concentric rings. Through experimental simulations and measurements, the vibration's modes as well as the acoustic field of radiation has been characterized. For the simulation, the method of finite elements was applied. For these transducers it was verified a decoupling between the modes of radial and thickness vibration. The fields radiated have shown that there are less effects of diffraction on Bessel transducers than on the conventional transducers. With this new implemented technology, not reported before in the literature, the limited-diffraction transducer does not require a sophisticated electronic set up to excite acoustic waves in the transducer, allowing to get a collimated radiation field desirable for medical applications with optimized lateral resolution. / Nas duas últimas décadas tem aumentado a importância do estudo de feixes de ultra-som de difração limitada em imagens médicas, caracterização de tecidos, estimação de velocidade Doppler (fluxo sanguíneo) e em outras áreas da Física. No trabalho realizado se implementou uma solução alternativa para produzir um transdutor de difração limitada, com uma polarização macroscópica do tipo função de Bessel. Estes transdutores (chamados também de Transdutores Bessel) foram construídos usando um disco cerâmico ferroelétrico de PZT dopado com Nióbio (Nb) utilizando uma técnica simples de polarização direta. Os eletrodos nas faces da cerâmica foram conformados colocando pintura de prata em forma de três anéis concêntricos. Através de simulações e medidas experimentais, foram caracterizados os seus modos de vibração assim como o campo acústico de radiação. Para as simulações, aplicou-se o método de elementos finitos. Para estes transdutores foi verificado um maior desacoplamento entre os modos de vibração radial e espessura. Os campos irradiados mostraram menores efeitos de difração comparados com os transdutores convencionais. O transdutor de difração limitada, construído com a tecnologia implementada neste trabalho, não reportada antes na literatura, não requer uma eletrônica de excitação complicada (como em alguns casos reportados na literatura) para gerar ondas acústicas no transdutor e obter um feixe acústico desejado para aplicações médicas: aquele que atinge maior profundidade de campo sem sofrer quase efeitos de difração e apresenta ótima resolução lateral.

Page generated in 0.0855 seconds