• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 80
  • 52
  • 20
  • 12
  • 12
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudio de los modos resonantes ferromagnéticos del sistema válvula de espín IrMn(151515nm)/Co(555nm)/Ru(ttt)/NiFe(555nm) (t=2.4,3.2,20 nm)

Tarazona Coronel, Heisemberg Samuel January 2015 (has links)
En el presente trabajo se hace un estudio teórico de la resonancia ferromagnética en un tipo especial de multicapa magnética llamada “válvula de espín”. Dicha válvula de espín consiste de dos capas ferromagnéticas separadas por un espaciador no magnético que en conjunto se encuentran sobre un substrato antiferromagnético. Respecto a la válvula de espín es bien sabido que el espesor del espaciador no magnético juega un rol clave en el comportamiento electrónico y magnético de esta multicapa, la cual, en ausencia de un campo externo, da lugar a la existencia de un acoplamiento entre las magnetizaciones de las capas ferromagnéticas. Para estudiar este acoplamiento magn´etico se hace uso de la ecuación de Landau-Lifshitz ya que ésta describe muy bien la dinámica de la magnetización y su evolución temporal, donde la frecuencia de precesión de la magnetización está determinada por el campo interno local Heff. Este campo proviene de distintas fuentes tales como: anisotropías de forma, magnetocristalina, de superficie y campo externo. Por ende,siguiendo el modelo de Smity Beljers [Smit55],se puede utilizar la energía libre total del sistema para obtener el campo efectivo interno Heff y resolver la ecuación de Landau-Lifshitz para pequeñas osilaciones de la magnetización. Como resultado, se obtiene la relación de dispersión en la que se encuentra implícita la dependencia entre la frecuencia de resonancia y el campo externo; que está en buen acuerdo con lo publicado en la literatura [Layadi 05],[Zhang 94].Por otro lado, si se mantiene fija la frecuencia de resonancia f, se obtiene el campo de resonancia en función de su orientación dentro del plano de las capas, las cuales se encuentran también en buen acuerdo con lo publicado [Azevedo 05]. Además cabe resaltar que estos resultados teóricos se han utilizado para el estudio del sistema IrMn/Co/Ru(t)/FeNi [Alayo 11], para distintos espesores t de la capa no magnética, identificándose tres tipos de acoplamiento de intercambio intercapa o fuerza de acoplamiento J. Para t=200 ˚A se observa una simetría en la dependencia angular del campo de resonancia indicando que no existe un acoplamiento entre las capas magnéticas debido al gran espesor de la capa espaciadora. Para t=32 ˚A se observa un acoplamiento antiferromagnético; es decir, las magnetizaciones se encuentran alineadas antiparalelamente en el cual hay una gran contribución del acoplamiento bicuadrático. Finalmente, para t=24 ˚A se observa un acoplamiento paralelo o ferromagnético de las magnetizaciones. / Tesis
2

Valvotomia mitral com cateter balão

Mangione, Jose Armando 14 July 2018 (has links)
Orientadores : Eduardo A. Nogueira, Siguemituzo Arie / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-14T04:23:19Z (GMT). No. of bitstreams: 1 Mangione_JoseArmando_D.pdf: 3330360 bytes, checksum: 2c9e62e05b7f5270eebf10dd489be9f3 (MD5) Previous issue date: 1992 / Resumo: 1. Objetivo: o objetivo deste estudo foi mostrar as características clínicas, radiológicas, eletrocardiográficas, ecocardiográficas e hemodinâmicas dos pacientes que obtiveram sucesso (G-A) ou insucesso (G-B) através da valvotomia mitral com cateter balão (VMCB), avaliar os dados evolutivos, comentar as complicações ocorridas e também a ultilização do procedimento em pacientes grávidas. 2. Casuística e métodos: De janeiro de, 1988 a julho de 1990, 50 pacientes foram submetidos à VMCB. A idade variou de 16 a 73 anos, média de 36,3 ! 13,3 anos. Quarenta e cinco (88%) eram do sexo feminino, sendo 7 (14%) gestantes com idade gestacional média de 24,6 +- 9,5 semanas. Foram selecionados para o procedimento pacientes com área valvar menor que 1,5cm2, sem história pregressa de tromboembolismo, sem evidências de trombo em átrio esquerdo e sem outras lesões valvares cirúrgicas associadas. Os pacientes foram submetidos à avaliação clínica, radiológica, eletrocardiográfica, ecocardiográfica e hemodinâmica antes, imediatamente após a VMCB e no controle evolutivo que variou de 3 a 33 meses. A VMCB foi realizada pela técnica anterógrada por punção do septo interatrial ¿Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital. / Abstract: 1. Purpose: The purpose of this investigation was to analyse clinical, radiologic, eletrocardiographic, echocardiographic and hemodynamic caracteristics of the patients that underwent mitral balloon valvotomy,assess the follow-up data,comment the complications and its usefullness in pregnant women. 2. patients and Methods: We studied the data from 50 patients that underwent mitral balloon valvotomy from January 1988 to July 1990. The mean age was 36.3f13.3 years, ranging from 16 to 73 years. Forty-five (88%) were women, seven (14%) were pregnant with mean gestational age of 24.6 +- 9.5 weeks. The selected patients had mitral valve area less than 1.5cm2 and no previous stroke, no evidence of left atrial thrombus or other significant cardiac valve disease. Clinical examination, eletrocardiographic, radiologic, echocardiographic and hemodynamic evaluation were performed before and immediately after valvotomy and in the follow-up period that ranged from 3 to 33 months. Mitral balloon valvotomy was performed by transeptal technique ...Note: The complete abstract is available with the full electronic digital thesis or dissertations. / Doutorado / Doutor em Ciências Médicas
3

Anatomia cirurgica da estenose mitral : aspecto valvar

Fortuna, Antonio Benedicto Prado, 1928- 16 July 2018 (has links)
Acompanha Bibliografia, Discussão / Tese (livre-docencia) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-16T14:51:23Z (GMT). No. of bitstreams: 1 Fortuna_AntonioBenedictoPrado_LD.pdf: 9060882 bytes, checksum: b6eabef0abe356e074f8b1776ad45de6 (MD5) Previous issue date: 1983 / Sem resumo. / Tese (livre-docencia) - Univer / Livre-docente em Cirurgia Cardiaca
4

Morfologia e morfometria da valva mitral de cadaveres da posição coaptada : um trabalho de correlação anatomo-ecocardiografica

Curti, Heraldo Jose Vivarelli 22 October 1993 (has links)
Orientador : Luiz Antonio Kannebley Bittencourt / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-18T20:02:09Z (GMT). No. of bitstreams: 1 Curti_HeraldoJoseVivarelli_D.pdf: 3994282 bytes, checksum: c59ce9e48d72a157755ccd427e4a7140 (MD5) Previous issue date: 1993 / Sem resumo. / Doutorado / Doutor em Ciências Médicas
5

Avaliação tribológica do par válvula e sede de válvula de admissão de um motor ciclo diesel em condições reais de funcionamento / Tribological evaluation of intake valve and valve seat of a diesel cycle engine in real operating conditions

Penhalbel, Luciano Tadeu Baffi 01 November 2017 (has links)
A indústria automotiva exige produtos que trabalhem em condições extremas. O desenvolvimento de componentes é uma ação de aperfeiçoar os motores de combustão interna para que atinjam a vida requerida com níveis de desgaste aceitáveis, respeitando os limites legais de operação, como por exemplo, valores de emissões de poluentes. Diante dessas exigências, se faz necessário estudar componentes considerados críticos que conhecidamente influenciam no desempenho do motor. A tribologia do par válvula e sede de válvula de admissão é um importante conjunto que se deve ter atenção quanto ao seu desgaste, visto que pode influenciar na degradação do motor quanto aos parâmetros de emissões de poluentes e requisitos operacionais de manutenção e de vida do produto. O objetivo foi avaliar o comportamento do par tribológico, válvula e sede de válvula de admissão, submetidos a ensaios em dinamômetro e veiculares (condições reais de operação), quanto ao nível e tipo de desgaste ocorrido no par. Os resultados obtidos foram correlacionados com os requisitos de desempenho legais e operacionais de um motor ciclo diesel, como também foi realizada a caracterização do tipo de desgaste ocorrido no par tribológico e comparada com a literatura específica. Com base nos resultados, concluiu-se que ocorreu uma excelente compatibilidade entre a válvula e a sede da válvula de admissão; o nível de desgaste não prejudicou o desempenho do motor e as emissões de poluentes; o par tribológico atendeu aos requisitos de trabalho extremos, como operação em altas temperaturas e pressão de combustão com baixas taxas de desgaste; e os tipos de desgastes observados foram classificados como desgaste adesivo e sinais de deformação plástica. / Automotive industry demands products that work under extreme conditions. The development of components for internal combustion engines is an action to improve this product, so that it reaches the required life with acceptable levels of wear and respecting the legal operating limits, such as values of emission pollutants. In view of these requirements, it is necessary to study components considered critical, which are known to influence the performance of the engine. So within this universe the tribology of the intake valve and valve seat insert is an important set, that must receive attention to its wear and consequently its influence to the engine degradation in the parameters of emission pollutants and performance related to the operational maintenance requirements and life of the product. The aim of this work is to evaluate the behavior of the tribological intake pair, valve and valve seat insert, submitted to dynamometer and vehicular tests (real operating conditions), regarding the level and type of wear occurred in the pair. The results were compared with legal and operational performance requirements of a diesel cycle engine, as well as the characterization of the wear type occurred in the tribological pair, with the related literature. Based on the results it was concluded that there was excellent compatibility between the valve and the valve seat material; the wear level did not impar the engine performance and emissions of pollutants; the tribological pair meeting extreme work requirements, such as high temperature operation and combustion pressure while maintaining low wear rates. The wear types observed were classified as adhesive wear and slight signs of shear strain wear.
6

Avaliação tribológica do par válvula e sede de válvula de admissão de um motor ciclo diesel em condições reais de funcionamento / Tribological evaluation of intake valve and valve seat of a diesel cycle engine in real operating conditions

Luciano Tadeu Baffi Penhalbel 01 November 2017 (has links)
A indústria automotiva exige produtos que trabalhem em condições extremas. O desenvolvimento de componentes é uma ação de aperfeiçoar os motores de combustão interna para que atinjam a vida requerida com níveis de desgaste aceitáveis, respeitando os limites legais de operação, como por exemplo, valores de emissões de poluentes. Diante dessas exigências, se faz necessário estudar componentes considerados críticos que conhecidamente influenciam no desempenho do motor. A tribologia do par válvula e sede de válvula de admissão é um importante conjunto que se deve ter atenção quanto ao seu desgaste, visto que pode influenciar na degradação do motor quanto aos parâmetros de emissões de poluentes e requisitos operacionais de manutenção e de vida do produto. O objetivo foi avaliar o comportamento do par tribológico, válvula e sede de válvula de admissão, submetidos a ensaios em dinamômetro e veiculares (condições reais de operação), quanto ao nível e tipo de desgaste ocorrido no par. Os resultados obtidos foram correlacionados com os requisitos de desempenho legais e operacionais de um motor ciclo diesel, como também foi realizada a caracterização do tipo de desgaste ocorrido no par tribológico e comparada com a literatura específica. Com base nos resultados, concluiu-se que ocorreu uma excelente compatibilidade entre a válvula e a sede da válvula de admissão; o nível de desgaste não prejudicou o desempenho do motor e as emissões de poluentes; o par tribológico atendeu aos requisitos de trabalho extremos, como operação em altas temperaturas e pressão de combustão com baixas taxas de desgaste; e os tipos de desgastes observados foram classificados como desgaste adesivo e sinais de deformação plástica. / Automotive industry demands products that work under extreme conditions. The development of components for internal combustion engines is an action to improve this product, so that it reaches the required life with acceptable levels of wear and respecting the legal operating limits, such as values of emission pollutants. In view of these requirements, it is necessary to study components considered critical, which are known to influence the performance of the engine. So within this universe the tribology of the intake valve and valve seat insert is an important set, that must receive attention to its wear and consequently its influence to the engine degradation in the parameters of emission pollutants and performance related to the operational maintenance requirements and life of the product. The aim of this work is to evaluate the behavior of the tribological intake pair, valve and valve seat insert, submitted to dynamometer and vehicular tests (real operating conditions), regarding the level and type of wear occurred in the pair. The results were compared with legal and operational performance requirements of a diesel cycle engine, as well as the characterization of the wear type occurred in the tribological pair, with the related literature. Based on the results it was concluded that there was excellent compatibility between the valve and the valve seat material; the wear level did not impar the engine performance and emissions of pollutants; the tribological pair meeting extreme work requirements, such as high temperature operation and combustion pressure while maintaining low wear rates. The wear types observed were classified as adhesive wear and slight signs of shear strain wear.
7

Plastica mitral com anel maleavel de pericardio bovino.

Volpe, Marco Antonio 06 February 1997 (has links)
Orientador: Domingo Marcolino Braile / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-07-22T11:19:40Z (GMT). No. of bitstreams: 1 Volpe_MarcoAntonio_M.pdf: 4869546 bytes, checksum: 527a2dc706b96d2ae7469dbd264bcfaa (MD5) Previous issue date: 1997 / Resumo: No final da década de 50, realizou-se a primeira tentativa de corrigir a insuficiência mitral pura por anuloplastia. Desde então, numerosas técnicas têm sido propostas na correção das valvopatias. O presente trabalho mostra os resultados obtidos com doentes submetidos a uma variedade de plástica mitral. A técnica consiste em medir o perímetro da cúspide anterior e implantar uma prótese flexível de pericárdio bovino, com esta medida, para reforço e conformação do anel mitral posterior. Assim, obtém-se redução do anel mitral posterior ao perímetro da cúspide anterior, com perfeito ajuste do aparelho valvar. Foram estudados 32 doentes, em 16 meses, com seguimento de 100%. Destes, 25 eram do sexo feminino e 7 do masculino, com idade variando de 9 a 66 anos (M = 36,38 ± 17,18 anos). A abordagem mitral foi exclusiva em 23 (72%) doentes, enquanto os demais (9) foram submetidos a operações associadas, como plástica tricúspide (4), troca valvar aórtica (3) e plástica aórtica (2). Não se registrou óbito operatório. Houve 2 óbitos (6,2%), sendo um de causa desconhecida e outro no terceiro dia de pós-operatório de uma troca valvar mitral realizada 9 meses após a anuloplastia. Registrou-se sobrevida de 93,8%. Entre as complicações tardias não fatais, o tromboembolismo e a endocardite não registraram eventos nos 16 meses de estudo. Houve apenas uma reoperação nesse período. Na avaliação ecodopplercardiográfica, 88% dos doentes mostraram completa recuperação funcional da valva mitral (50% com ausência de insuficiência e 38% com insuficiência leve e sem repercussão hemodinâmica). Dos 12% (4 doentes) restantes, 6% apresentaram insuficiência moderada e 6% permaneceram com insuficiência grave. Segundo a classificação da N.Y.H.A., os doentes das classes II (28%) e III (72%) passaram para as classes I (65%), II (32%) e III (3%). O anel de pericárdio bovino mostrou-se flexível, moldando-se perfeitamente ao anel valvar, respeitando sua geometria e contratilidade. Não produziu hemólise e permitiu a seus portadores prescindirem de anticoagulação. Desse modo, o reparo da valva mitral por meio desta técnica pareceu simples e facilmente reprodutível, com vantagens significantes na evolução dos doentes / Abstract: By the end of the 50's, the first attempt to correct the pure mitral insufficiency through annuloplasty was made. Since then, various techniques have been considered for the correction of valvopathies. This paper shows the results of patients undergoing a variety of mitral plastic. The technique consists of a perimeter measurement of the anterior cuspid and the implantation of a bovine pericardium flexible prosthesis, with that size, for reinforcement and conformation of the posterior mitral ring. Thus, it is possible to obtain the reduction of the posterior mitral ring towards the anterior cuspid perimeter, with a perfect adjustment of the valvar device. Thirty-two patients were studied, in 16 months, with a 100% follow-up. Twenty-five of them were females and 7 males, at the age range from 9 to 66 years (M=36,38 ± 17,18 years). The mitral approach was exclusive in 23 (72%) patients whereas the others (9) underwent operations associated, as tricuspid plastic (4), aortic valve replacement (3), aortic plastic (2). There were no reports of operative deaths. There were two deaths (6,2%), one had an unknown cause of death and one died on the third postoperative day following a mitral valve replacement that was performed 9 months after the annuloplasty. A survival of 93,8% was recorded. Among the late nonfatal complications, the thromboembolism and the endocarditis did not show any events in 16 months of study. There was only one reoperation within this period In the echodopplercardiography evaluation, 88% of the patients showed a complete functional recovery of the mitral valve (50% with absence of insufficiency and 38% with slight insufficiency with no hemodynamic repercussion). Of the 12% (4 patients) remaining, 6% showed moderate insufficiency and 6% remained with severe insufficiency. According to the N.Y.H.A. classification, the patients of classes H (28%) and m (72%) went on to classes 1 (65%), II (32%), and III (3%). The bovine pericardium ring was flexible enough, fitting the valvar ring perfectly, repecting its geometry and contractility. It did not produce hemolysis and allowed its sufferers to disregard anticoagulation. Thus, the mitral valve repair through this technique seemed simple and easily reproductive, with significant advantages in the evolution of the patients / Mestrado / Clinica Medica / Mestre em Ciências Médicas
8

Reavaliação do mecanismo de fechamento das valvas atrio-ventriculares por meio de registros manometricos e impedanciometricos da dinamica cardiaca : estudo experimental em cães

Maciel, Rui Errerias, 1943- 15 July 2018 (has links)
Tese (livre-docencia) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-07-15T09:21:01Z (GMT). No. of bitstreams: 1 Maciel_RuiErrerias_LD.pdf: 4479550 bytes, checksum: 72a82d1e70b702f24b47e2262d1d5c26 (MD5) Previous issue date: 1976 / Resumo: O autor realizou um estudo reavaliatório do mecanismo de fechamento das valvas átrio-ventriculares ¿ empregando técnicas manométricas tradicionais e impedanciométricas por ele desenvolvidas, com o intuito de auxiliar a compreensão de tal mecanismo e reavivar as pesquisas neste campo, pois apesar das muitas controvérsias ¿ existentes, o assunto deixou de ser estudado, ou por dificuldades técnicas, ou pelo comodismo de encará-lo como um evento completamente esclarecido. Dos resultados experimentais e da discussão dos fatores que a ele se relacionam, decorrem elementos que corroboram as seguintes hipóteses: 1 ¿ Não há inversão do gradiente de pressão átrio-ventricular antes do fechamento valvular normal. 2 ¿ Durante esta oclusão não há refluxo de sangue ventrículo-atrial. 3 ¿ O fechamento é eficiente durante a estimulação parassimpática necessária apenas para diminuir a freqüência atrial, sem inibir completamente a sua contração. 4 ¿ A lesão do nódulo sino atrial modifica o mecanismo de fechamento valvar de atriogênico para ventriculogênico. 5 ¿ A lesão do nódulo sino atrial produz, instantaneamente, uma insuficiência aguda das valvas átrio ventriculares. 6 ¿ A inatividade atrial ocasiona um desperdício de energia pelo ventrículo para realizar o fechamento valvar. 7 ¿ A contração atrial é eficiente como ¿bomba¿ produtora de energia / Abstract: Not informed. / Tese (livre-docencia) - Univer / Livre Docente em Ciencias Biologicas
9

Análises numérica e experimental em bancada do impacto entre válvula e anel inserto em motores de combustão interna/

Daminato, G. January 2015 (has links) (PDF)
Dissertação (Mestrado em Engenharia Mecânica) - Centro Universitário da FEI, São Bernardo do Campo, 2015
10

Amplificação dos genes que codificam a Endotelina-1 e seus receptores em valvas mitrais reumáticas

Moura, Edmilson Bastos de January 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Medicina, 2008. / Submitted by Natália Cristina Ramos dos Santos (nataliaguilera3@hotmail.com) on 2009-09-10T12:22:59Z No. of bitstreams: 1 2008_EdmilsonBastosdeMoura.pdf: 1746669 bytes, checksum: c25edd64b2c89dd0421a0aa41d8f1c8b (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2009-10-05T16:32:53Z (GMT) No. of bitstreams: 1 2008_EdmilsonBastosdeMoura.pdf: 1746669 bytes, checksum: c25edd64b2c89dd0421a0aa41d8f1c8b (MD5) / Made available in DSpace on 2009-10-05T16:32:53Z (GMT). No. of bitstreams: 1 2008_EdmilsonBastosdeMoura.pdf: 1746669 bytes, checksum: c25edd64b2c89dd0421a0aa41d8f1c8b (MD5) Previous issue date: 2008 / Introdução: o estudo da substância vasoconstritora endotelina-1 e de seus receptores A e B, desde sua descoberta em 1988, tem crescido progressivamente nos últimos anos. Isso se deve ao seu reconhecimento como elemento crítico na fisiopatologia de diversas doenças, com destaque para aquelas de acometimento cardiovascular. Sua função na vasorreatividade já é conhecida, bem como sua ação parácrina e autócrina, o que conduz à procura de seus sítios de produção nos diversos tecidos. Essa busca objetiva desvendar a contribuição de cada órgão no processo patológico, e também determinar a participação de tais peptídeos nas modificações sofridas pelo próprio tecido nesse processo (como a deposição de colágeno, ou a neovascularização). Nesse contexto, a valvopatia reumática revela-se uma boa candidata à pesquisa, pelas suas características mudanças estruturais valvares e pela repercussão que impõe à todo o sistema cardiovascular e pulmonar. Objetivo: determinar, mediante técnicas moleculares, a expressão dos genes da endotelina e dos seus receptores em valvas mitrais reumáticas. Metodologia: 27 pacientes submetidos a troca valvar mitral tiveram seu tecido valvar analisado para determinação da presença de genes da ET-1 e seus receptores A e B; foi feita análise histológica e molecular das valvas (divididas em fragmentos M1, M2 e M3) e colhidos dados clínicos e epidemiológicos dos pacientes. Foram divididos em 3 grupos (valvopatia mitral, mitroaórtica, pacientes reoperados). Resultados: O estudo mostrou a manifestação do gene da endotelina-1 em 40,7% dos espécimes e de seu receptor A em todas as amostras, com manifestação minoritária do gene do receptor B (22,2%). Conclusões: todos os pacientes expressaram a presença do gene do receptor A; não houve diferença estatística quanto a gravidade da doença, expressa em classe funcional, e os subgrupos estudados (valvopatas mitrais, mitro-aórticos e pacientes reoperados), ou quanto a expressão dos genes da ET-1 e seus receptores, entre os subgrupos estudados (valvopatas mitrais, mitro-aórticos e pacientes reoperados). ____________________________________________________________________________________ ABSTRACT / Introduction: the study of the vasoconstrictor substance endothelin-1 and its receptors A and B, since its discovery in 1988, has grown gradually in the last years. This is due to their recognition as a critical element in the pathophysiology of many diseases, with emphasis on those from cardiovascular involvement. His role in vasorreactivity is already known, as well as its autocrine and paracrine actions, leading to demand for its production sites in various tissues. This search aims to unveil the contribuction of each organ in the pathological process, and also determine the involvement of these peptides in the modifications made by the tissue in the process (as the deposition of collagen, or neovascularization). In this context, rheumatic valve disease proves to be a good candidate to search, due their characteristics valve structural changes and the impact of the whole cardiovascular and pulmonary sistems. Objective: to determine, through molecular techniques, the expression of genes of endothelin and its receptors in rheumatic mitral valves. Methodology: 27 patients undergoing mitral valve replacement had their valve tissue analyzed for determining the presence of genes of ET-1 and its receptors A and B; was made histological and molecular analysis of the valves and collected clinical and epidemiological data of patients. They were divided into 3 groups (mitral valvophaty, mitroaortic, patients reoperated). Results: the study showed the gene expression of enothelin-1 in 40,7% of the samples, and its receptor A in all samples, with minority manifestation of the gene of receptor B (22,2%). Conclusions: all patients expressed the gene of receptor A; there was no statistical difference regarding the severity of illness, expressed in functional class, and the subgroups studied (mitral valvophaty, mitroaortic and reoperated patients), or in the expression of genes of ET-1 and their receptors, among the subgroups studied.

Page generated in 0.0405 seconds