• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1130
  • 460
  • 250
  • 216
  • 149
  • 83
  • 79
  • 39
  • 38
  • 24
  • 22
  • 22
  • 18
  • 14
  • 8
  • Tagged with
  • 3002
  • 941
  • 531
  • 519
  • 517
  • 477
  • 435
  • 359
  • 343
  • 313
  • 293
  • 281
  • 262
  • 259
  • 226
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

A Study on Wind Turbine Low Voltage Ride Through Capability Enhancement by STATCOM and DVR

Lin, Chih-peng 05 February 2010 (has links)
When more induction generator based wind farms are integrated into the power system, the system voltage dips and stability problems may arise due to the draw of reactive power by induction generators. The power system short-circuit event induced wind turbine trips could result in power imbalance and lead to power system instability. This thesis studies the influence of two compensation techniques on the wind turbine low voltage ride-through (LVRT) capability. One of which is based on a parallel compensation by a static synchronous compensator (STATCOM), and the other one is a series compensation by a dynamic voltage restorer (DVR). In this study, Matlab tools and models are used to simulate an active-stall controlled fixed-speed induction generator connected to a power system. Two system configurations are used to simulate three phase faults and compare the improvement of wind turbine LVRT capability due to the two studied compensation techniques. Simulation results indicate that wind turbine compensated by DVR would have better LVRT performance than that by STATCOM in dealing with the low voltage situations due to system faults.
132

Estimation of Sensitive Equipment Disruptions Due to Voltage Sags

Shen, Cheng-Chieh 12 July 2007 (has links)
Voltage sag (dip), a sudden reduction of the voltage magnitude within a short duration in power system, is one of major concerns of power quality problems. The main reason of the increased concerns for voltage sag problems is that the losses caused by voltage sag events are high and not negligible. Reliability indices have been used for many years to quantify the effect of sustained interruptions on the electric power system. Power quality indices reflecting the severity of various power quality problems, such as flicker, harmonics, voltage swell and sag conditions, power factor, losses, electromagnetic interference, and other phenomena, are still under development. The representation and classification of voltage sags have been studied recently by standard-setting organizations. In order to find compatibility between service quality and the equipment adopted and a least cost solution for possible power quality problems, the concept of system disturbance level and equipment immunity level was proposed in IEC 61000-3-7 but without clear definitions. A novel voltage sag index based on fuzzy logic technique to quantify system disturbance and equipment immunity levels is proposed in this dissertation. This approach takes network vulnerability, equipment sensitivity and uncertainties in measuring voltage sags into account, thereby, providing meaningful information for both the utility and customers. Using the proposed method, the probabilistic distribution of system disturbances can be obtained from the single event indices of all events recorded and the probabilistic distribution of equipment sag immunity capability can be evaluated based on the device voltage sag tolerance curve. This dissertation also presents a novel framework for predicting the number of equipment disruptions due to voltage sags in a unit of time by using the disturbance and immunity levels concepts. In the proposed approach, the number of disruptions is computed by using the unreliability concept. The area of overlapping between the distributions of site disturbance and equipment immunity levels, which indicates the number of possible disruptions, is calculated based on interference theory and reliability computations. The presented methodology can be used as a planning tool to quantify the system disturbances and equipment sensitivity. It can also be used to perform cost analysis of the compatibility of equipment with an electric power system. To minimize the costs due to voltage sags, it is always a good strategy to maintain a minimum overlap between the equipment immunity level and site disturbance level to have satisfactory operation of the equipment. The tool achieved in this work can be used to perform such analyses.
133

Accelerated Aging Study of Machine Winding Insulation under AC and High Frequency Pulse Voltage Application

Chalise, Sajal Raj 01 May 2010 (has links)
It is common practice to perform accelerated aging with 60 Hz ac to determine the lifetime characteristics of insulation used in the machine. Comparable breakdown measurements are performed at different voltage levels and temperatures for the polyimide insulated machine winding under normal operating conditions of 60 Hz ac. The result shows that the time to failure can be represented by the inverse power law and the Arrhenius equation with respect to test voltage and temperature respectively. However, the use of power electronic devices causes harmonics, and spikes that electrically degrade the machine winding insulation. Applied high frequency pulse voltages can be used to study the impact of electrical degradation of the machine winding insulation that exists in electrical machines. Evaluation of change in dielectric strength, partial discharge and breakdown voltage is monitored versus aging caused by high frequency pulse voltage at 90% of operating temperature.
134

High Slew Rate High-efficiency Dc-dc Converter

Wang, Xiangcheng 01 January 2006 (has links)
Active transient voltage compensator (ATVC) has been proposed to improve VR transient response at high slew rate load, which engages in transient periods operating in MHZ to inject high slew rate current in step up load and recovers energy in step down load. Main VR operates in low switching frequency mainly providing DC current. Parallel ATVC has largely reduced conduction and switching losses. Parallel ATVC also reduces the number of VR bulk capacitors. Combined linear and adaptive nonlinear control has been proposed to reduce delay times in the actual controller, which injects one nonlinear signal in transient periods and simplifies the linear controller design. Switching mode current compensator with nonlinear control in secondary side is proposed to eliminate the effect of opotocoupler, which reduces response times and simplifies the linear controller design in isolated DC-DC converters. A novel control method has been carried out in two-stage isolated DC-DC converter to simplify the control scheme and improve the transient response, allowing for high duty cycle operation and large step-down voltage ratio with high efficiency. A balancing winding network composed of small power rating components is used to mitigate the double pole-zero effect in complementary-controlled isolated DC-DC converter, which simplifies the linear control design and improves the transient response without delay time. A parallel post regulator (PPR) is proposed for wide range input isolated DC-DC converter with secondary side control, which provides small part of output power and most of them are handled by unregulated rectifier with high efficiency. PPR is easy to achieve ZVS in primary side both in wide range input and full load range due to 0.5 duty cycle. PPR has reduced conduction loss and reduced voltage rating in the secondary side due to high turn ratio transformer, resulting in up to 8 percent efficiency improvement in the prototype compared to conventional methods.
135

Proximity and Thickness Estimation of Aluminum 3003 Alloy Metal Sheets Using Multi-Frequency Eddy Current Sensor

Kamanalu, Sunil S. 28 October 2010 (has links)
No description available.
136

Artificial intelligence techniques for power system decision problems

Chui, David Kam Hung January 1989 (has links)
No description available.
137

A quantitative enzyme linked immunosorbent assay for polychlorinated biphenyls in transformer oil

Kim, In Soo January 2000 (has links)
No description available.
138

Quantal analysis of synaptic transmission in CA1 pyramidal cells of the rat hippocampus

Isaac, John Timothy Roger January 1993 (has links)
No description available.
139

Environmental parameter for cable ratings

Theed, Justin Edward January 1999 (has links)
No description available.
140

The fabrication and characterisation of 4H-SiC Schottky barrier diodes

Morrison, Dominique Johanne January 2000 (has links)
No description available.

Page generated in 0.0375 seconds