• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Long term thermal performance and application of glass fiber core vacuum insulation panels

Chan, Vivian 22 December 2020 (has links)
Glass fiber core Vacuum Insulation Panels (VIPs) have thermal performance per unit thickness of about 5-10 times higher than the traditionally used building insulation materials such as mineral wool, XPS, EPS, foam, etc. This advantage of VIP has made it very attractive new option for innovative building designs. Especially in Canada, where some of the areas have long and very cold winters. Confidence in the service life of a building material is necessary before putting a product to market. Extensive research has been conducted on the product development, quality improvement, and field application of VIPs around the world. However, there is lack of consistent and simple prediction method for the long-term thermal performance of VIPs. This paper discussed the process and performance of a field project using glass fiber VIPs to retrofit a commercial building in Yukon, Canada. The thermal performance of the VIPs used in this project was continuously monitored and critically analyzed since the start in 2011. The results have shown satisfactory thermal performance of VIPs for the past 8 years. The findings were also used to validate glass fiber core VIP accelerated aging tests conducted by the National Research Council Canada (Ottawa), and the aging rate of VIPs in a cold and dry climate was determined. The second part of this study investigated the monitored performance results from two sets of simplified accelerated laboratory aging tests, the results were analyzed with the aim to separate the impact of air diffusion from water vapour on the long-term thermal performance of glass fiber VIPs. In addition, this study also investigated the potential application of VIPs in balcony constructions to reduce heat transfer through thermal bridges. Computer modeling exercises, using a benchmarked (EN ISO 10211) three-dimensional transient and steady-state heat transfer simulation tool HEAT3, were carried out on the most optimal (thermal performance) balcony assemblies of wood framed buildings using VIP as insulation. This niche application of VIPs can significantly increase the energy efficiency of building envelopes/skins in extreme climates of Canada and elsewhere in the world. / Graduate / 2021-11-06
2

Promotion of sustainable renovation in the built environment : An early stage techno-economic approach

Gohardani, Navid January 2012 (has links)
According to the Swedish Government's set targets for energy use and environmental quality imposed by the European Union, the total energy per heated unit area in residential and commercial buildings will have to be decreased by 20% in 2020 and 50% by 2050 in relation to the annual consumption of 1995. The building sector should additionally be completely independent of fossil fuels for energy usage, with the increasing sector of renewable energy continuously growing until 2020. In its current state, the number of multistory buildings and single-family houses in Sweden exceeds 4 000 000 units. In order to attain the set goals, renovation of the existing housing stock is a necessity given its current relatively slow turnover. As a result of the Swedish Million Unit Program undertaken during 1965−1974, about 750 000 apartments are currently in need of renovation in order to meet today's building standards. Simultaneously, new buildings are built with energy efficiency in mind. In this study an early stage methodology is developed for building refurbishment that takes advantage of a multi-faceted approach. The methodology comprises of multiple dimensions related to a techno-economic, environmental and building occupancy approach. The work presented herein includes a thorough literature review of decision making tools within the built environment and identifies major research efforts in sustainable refurbishment. The technical aspect of this study deals with the proper identification of high-efficient insulation materials that would serve one of the set purposes of energy efficiency when utilized within building envelopes. Further, results are shown for case studies, in which economic investments in Vacuum Insulation Panels (VIPs) and a coupled heat and moisture transport for predefined configurations of VIPs with supplementary insulation of balcony slabs and wall cross-sections are considered. The developed methodology also examines simulations of the total energy consumption utilizing a set of different insulation materials such as mineral wool and VIPs, for a number of locations in Northern and Southern Europe. The research findings of this study identify several aspects of a new developed tool for decision making, to be used in sustainable renovation and refurbishment. / <p>QC 20120918</p>
3

Case study of the energy performance of a school building in Laholm, Sweden : Energy modeling for the formulation of efficient renovation strategies

Gutiérrez Prieto, Daniel Andrés January 2022 (has links)
This study has been focusing on a school located in the municipality of Laholm, South of Sweden. Employing an energy balance of the last five (5) years, a proposal for measures is made in terms of performance for comparison with the baseline of the current consumption trend. This comparison allowed us to narrow down the alternatives for the renovation with the potential to have a great impact on the school's energy use and indoor environment, but also on the preserved characteristics without any violation of the laws and regulations. A complementary analysis was used to analyze important variables for decision-making and implementation of improvements. This analysis consists of an exergy analysis which was utilized as a pre-design tool for an optimized building renovation proposal. Exergy losses were calculated to assess the performance of the systems. The study revealed that in relation to the use of new technologies and materials, aerogel and vacuum insulation panels bring relevant savings as their insulation mechanisms are the most efficient for such a building in a climate like Laholm. As for the heating system, it was evident that the use of a geothermal heat pump associated to PV panels brings considerable energy benefits when compared to the current oil boiler system and given that the village does not yet have a local district heating system. When the proposed measures are applied during 2022- 2023, the results will show that also older buildings can be energy efficient which is demanded of the buildings stock throughout the European Union.
4

Studium chování vláknitých materiálových struktur za sníženého tlaku / Study of behavior of fiber structures under low pressure

Heliová, Magdaléna January 2019 (has links)
The diploma thesis deals with study of behavior of fibrous organic insulants under greatly reduced pressure (even to vacuum). Development, production and durability of vacuum insulating panels are described in the theoretical part as well as principles of heat transfer. Method for production of core of VIP, created using waste fibers from textile industry and agriculture, is described in the practical part. Verification of behavior during normal and reduced pressure (even to vacuum) was carried out on experimentally made core insulants.
5

Advances in Thermal Insulation : Vacuum Insulation Panels and Thermal Efficiency to Reduce Energy Usage in Buildings

Thorsell, Thomas January 2012 (has links)
We are coming to realize that there is an urgent need to reduce energy usage in buildings and it has to be done in a sustainable way. This thesis focuses on the performance of the building envelope; more precisely thermal performance of walls and super insulation material in the form of vacuum insulation. However, the building envelope is just one part of the whole building system, and super insulators have one major flaw: they are easily adversely affected by other problems in the built environment.  Vacuum Insulation Panels are one fresh addition to the arsenal of insulation materials available to the building industry. They are composite material with a core and an enclosure which, as a composite, can reach thermal conductivities as low as 0.004 W/(mK). However, the exceptional performance relies on the barrier material preventing gas permeation, maintaining a near vacuum into the core and a minimized thermal bridge effect from the wrapping of barrier material round the edge of a panel. A serpentine edge is proposed to decrease the heat loss at the edge. Modeling and testing shows a reduction of 60% if a reasonable serpentine edge is used. A diffusion model of permeation through multilayered barrier films with metallization coatings was developed to predict ultimate service life. The model combines numerical calculations with analytical field theory allowing for more precise determination than current models. The results using the proposed model indicate that it is possible to manufacture panels with lifetimes exceeding 50 years with existing manufacturing. Switching from the component scale to the building scale; an approach of integrated testing and modeling is proposed. Four wall types have been tested in a large range of environments with the aim to assess the hygrothermal nature and significance of thermal bridges and air leakages. The test procedure was also examined as a means for a more representative performance indicator than R-value (in USA). The procedure incorporates specific steps exposing the wall to different climate conditions, ranging from cold and dry to hot and humid, with and without a pressure gradient. This study showed that air infiltration alone might decrease the thermal resistance of a residential wall by 15%, more for industrial walls. Results from the research underpin a discussion concerning the importance of a holistic approach to building design if we are to meet the challenge of energy savings and sustainability. Thermal insulation efficiency is a main concept used throughout, and since it measures utilization it is a partial measure of sustainability. It is therefore proposed as a necessary design parameter in addition to a performance indicator when designing building envelopes. The thermal insulation efficiency ranges from below 50% for a wood stud wall poorly designed with incorporated VIP, while an optimized design with VIP placed in an uninterrupted external layer shows an efficiency of 99%, almost perfect. Thermal insulation efficiency reflects the measured wall performance full scale test, thus indicating efficiency under varied environmental loads: heat, moisture and pressure. The building design must be as a system, integrating all the subsystems together to function in concert. New design methodologies must be created along with new, more reliable and comprehensive measuring, testing and integrating procedures. New super insulators are capable of reducing energy usage below zero energy in buildings. It would be a shame to waste them by not taking care of the rest of the system. This thesis details the steps that went into this study and shows how this can be done. / QC 20120228
6

An Approach Towards Sustainable Building

Gohardani, Navid January 2014 (has links)
The motivation for development of energy efficiency and implementation of novel advanced materials applied in buildings can be traced to increasing energy costs in conjunction with an enhanced environmental awareness among people. This doctoral dissertation presents contributions towards sustainable building, where factors such as building technology, energy efficiency in buildings, workers' health issues during construction measures, and certain economic considerations for renovation of buildings have been considered. The research study aims to provide a knowledge base for motivating building owners to renovate buildings based on energy efficiency and improved indoor environment. The initial phase of the research study identifies a detailed description of common drivers, expected in renovation projects by building owners. In the second phase, an information base is identified which may facilitate the bidding processes for decision makers by means of technological, social and economic aspects. The aforementioned information base can also contribute to attentive decisions regarding sustainable renovation and energy saving measures. A strategy was developed within the Renovation Workshop of Riksbyggen, in order to promote energy saving measures concurrent with major renovations in residential buildings. This operational decision support process was applied in a tenant owners' cooperative in Sweden. The objective of this process was to showcase and more importantly to implement energy saving measures, based on knowledge transfer between different parties involved in the renovation project. For the conducted case study, this process was shown to be of great importance when decisions regarding energy saving measures in conjunction with scheduled renovations are being planned. A unique case study was conducted on two of the most commonly used environmental certification programs for buildings in Sweden; Environmental Building (Miljöbyggnad) and GreenBuilding. Following a granted access to a limited database of submitted applications to Sweden Green Building Council, the most common mistakes in these were identified and categorized. This study contributed to further understanding about the level of ability among building consultants, comprehension of environmental certification, and enhancement of the ability to produce high-quality calculations concerning building-related energy usage. In addition, this insight can provide a basis for planning of continuing education of consultants within the field of building technology. For a church building, a study was conducted subsequent to an exchange of an existing electric coil heating system to a hydronic ground source heat pump system. Analyses of the energy demand and energy signature, prior to and after installation were carried out. The replacement of the original heating system with a ground source heat pump system for the church building constitutes a reduced energy consumption level of approximately 66%, at the average outside temperature of -2.30 °C. This study demonstrated that data from a detailed electric bill can be utilized in order to obtain the energy signature of the building and henceforth assess the energy savings. One aspect of the research, examined the decision making process related to sustainable renovation and refurbishment in buildings. The utilized methodology identified three distinct phases in order to instigate an engagement in sustainable renovation, by means of questionnaires and semi-structured interviews. In particular, the attitudes of stakeholders in Sweden, Denmark and Cyprus to sustainable building were studied through three separate case studies. Within the framework of this study, it was identified that building physics and durability are among the most important drivers for energy renovation. The results provided an insight into the renovation process in the aforementioned countries and identified that drivers such as improvement of indoor air quality and elimination of moisture in the building envelope are also of crucial importance. Another aspect of the conducted research highlights workplace accidents occurring within the Swedish construction sector. The purpose of this study was to serve as a useful tool to track the working environments of construction workers in order to reduce health and safety issues within the construction sector. The findings of this research suggest that despite laws, regulations or additional factors that seek to ensure a safe and healthy environment for construction workers, the Swedish construction work force still faces challenges. Moreover, it is identified that construction workers participating in the study call for additional measures to ensure occupational health and safety. Improved knowledge of economic performance and technical results of renovations can contribute to a snowball effect, with more property owners recognizing the value of energy aspects and thus provide an increased level of energy savings. / <p>QC 20140127</p> / A Concept for promotion of sustainable retrofitting and renovation in Early Stages (ACES)
7

Robust and Durable Vacuum Insulation Technology for Buildings

Karami, Peyman January 2015 (has links)
Today’s buildings are responsible for 40% of the world’s energy use and also a substantial share of the Global Warming Potential (GWP). In Sweden, about 21% of the energy use can be related to the heat losses through the climatic envelope. The “Million Program” (Swedish: Miljonprogrammet) is a common name for about one million housing units, erected between 1965 and 1974 and many of these buildings suffer from poor energy performance. An important aim of this study was to access the possibilities of using Vacuum Insulation Panels (VIPs) in buildings with emphasis on the use of VIPs for improving the thermal efficiency of the “Million Program” buildings. The VIPs have a thermal resistance of about 8-10 times better than conventional insulations and offer unique opportunities to reduce the thickness of the thermal insulation. This thesis is divided into three main subjects. The first subject aims to investigate new alternative VIP cores that may reduce the market price of VIPs. Three newly developed nanoporous silica were tested using different steady-state and transient methods. A new self-designed device, connected to a Transient Plane Source (TPS) instrument was used to determine the thermal conductivity of granular powders at different gaseous pressure combined with different mechanical loads. The conclusion was that the TPS technique is less suitable for conducting thermal conductivity measurements on low-density nanoporous silica powders. However, deviations in the results are minimal for densities above a limit at which the pure conduction becomes dominant compared to heat transfer by radiation. The second subject of this work was to propose a new and robust VIP mounting system, with minimized thermal bridges, for improving the thermal efficiency of the “Million Program” buildings. On the basis of the parametric analysis and dynamic simulations, a new VIP mounting system was proposed and evaluated through full scale measurements in a climatic chamber. The in situ measurements showed that the suggested new VIP technical solution, consisting of 20mm thick VIPs, can improve the thermal transmittance of the wall, up to a level of 56%. An improved thermal transmittance of the wall at centre-of-panel coordinate of 0.118 to 0.132 W m-2K-1 and a measured centre-of-panel thermal conductivity (λcentre-of-panel) of 7 mW m-1K-1 were reached. Furthermore, this thesis includes a new approach to measure the thermal bridge impacts due to the VIP joints and laminates, through conducting infrared thermography investigations. An effective thermal conductivity of 10.9 mW m-1K-1 was measured. The higher measured centre-of-panel and effective thermal conductivities than the published centre-of-panel thermal conductivity of 4.2 mW m-1K-1 from the VIP manufacturer, suggest that the real thermal performance of VIPs, when are mounted in construction, is comparatively worse than of the measured performance in the laboratory. An effective thermal conductivity of 10.9 mW m-1K-1 will, however, provide an excellent thermal performance to the construction. The third subject of this thesis aims to assess the environmental impacts of production and operation of VIP-insulated buildings, since there is a lack of life cycle analysis of whole buildings with vacuum panels. It was concluded that VIPs have a greater environmental impact than conventional insulation, in all categories except Ozone Depilation Potential. The VIPs have a measurable influence on the total Global Warming Potential and Primary Energy use of the buildings when both production and operation are taken into account. However, the environmental effect of using VIPs is positive when compared to the GWP of a standard building (a reduction of 6%) while the PE is increased by 20%. It was concluded that further promotion of VIPs will benefit from reduced energy use or alternative energy sources in the production of VIP cores while the use of alternative cores and recycling of VIP cores may also help reduce the environmental impact. Also, a sensitivity analysis of this study showed that the choice of VIPs has a significant effect on the environmental impacts, allowing for a reduction of the total PE of a building by 12% and the GWP can be reduced as much as 11% when considering both production and operation of 50 yes. Finally, it’s possible to conclude that the VIPs are very competitive alternative for insulating buildings from the Swedish “Million Program”. Nevertheless, further investigations require for minimizing the measurable environmental impacts that acquired in this LCA study for the VIP-insulated buildings. / Dagens byggnader ansvarar för omkring 40% av världens energianvändning och  står också för en väsentlig del av utsläppen av växthusgaser. I Sverige kan ca 21 % av energianvändningen relateras till förluster genom klimatskalet. Miljonprogrammet är ett namn för omkring en miljon bostäder som byggdes mellan 1965 och 1974, och många av dessa byggnader har en dålig energiprestanda efter dagens mått. Huvudsyftet med denna studie har varit att utforska möjligheterna att använda vakuumisoleringspaneler (VIP:ar) i byggnader med viss fokus på tillämpning i Miljonprogrammets byggnader. Med en värmeledningsförmåga som är ca 8 - 10 gånger bättre än för traditionell isolering erbjuder VIP:arna unika möjligheter till förbättrad termisk prestanda med minimal isolerings tjocklek. Denna avhandling hade tre huvudsyften. Det första var att undersöka nya alternativ för kärnmaterial som bland annat kan reducera kostnaden vid produktion av VIP:ar. Tre nyutvecklade nanoporösa kiselpulver har testats med olika stationära och transienta metoder. En inom projektet utvecklad testbädd som kan anslutas till TPS instrument (Transient Plane Source sensor), har använts för att mäta värmeledningsförmågan hos kärnmaterial för VIP:ar, vid varierande gastryck och olika mekaniska laster. Slutsatsen blev att transienta metoder är mindre lämpliga för utföra mätningar av värmeledningsförmåga för nanoporösa kiselpulver låg densitet. Avvikelsen i resultaten är dock minimal för densiteter ovan en gräns då värmeledningen genom fasta material blir dominerande jämfört med värmeöverföring genom strålning. Det andra syftet har varit att föreslå ett nytt monteringssystem för VIP:ar som kan användas för att förbättra energieffektiviteten i byggnader som är typiska för Miljonprogrammet. Genom parametrisk analys och dynamiska simuleringar har vi kommit fram till ett förslag på ett nytt monteringssystem för VIP:ar som har utvärderats genom fullskaleförsök i klimatkammare. Resultaten från fullskaleförsöken visar att den nya tekniska lösningen förbättrar väggens U-värde med upp till 56 %. En förbättrad värmegenomgångskoefficienten för väggen i mitten av en VIP blev mellan 0.118 till 0,132 W m-2K-1 och värmeledningstalet centre-av-panel 7 mW m-1K-1 uppnåddes. Detta arbete innehåller dessutom en ny metod för att mäta köldbryggor i anslutningar med hjälp av infraröd termografi. En effektiv värmeledningsförmåga för 10.9 mW m-1K-1 uppnåddes. Resultaten tyder även på att den verkliga termiska prestandan av VIP:ar i konstruktioner är något sämre än mätvärden för paneler i laboratorium. En effektiv värmeledningsförmåga av 10.9 mW m-1K-1 ger dock väggkonstruktionen en utmärkt termisk prestanda. Det tredje syftet har varit att bedöma miljöpåverkan av en VIP-isolerad byggnad, från produktion till drift, eftersom en livscykelanalys av hela byggnader som är isolerade med vakuumisoleringspaneler inte har gjorts tidigare. Slutsatsen var att VIP:ar har en större miljöpåverkan än traditionell isolering, i alla kategorier förutom ozonnedbrytande potential. VIP:ar har en mätbar påverkan på de totala utsläppen av växthusgaser och primärenergianvändningen i byggnader när både produktion och drift beaktas. Miljöpåverkan av de använda VIP:arna är dock positiv jämfört med GWP av en standardbyggnad (en minskning med 6 %) medan primärenergianvändningen ökade med 20 %. Slutsatsen var att ytterligare användning av VIP:ar gynnas av reducerad energiförbrukning och alternativa energikällor i produktionen av nanoporösa kiselpulver medan användningen av alternativa kärnmaterial och återvinning av VIP kärnor kan hjälpa till att minska miljöpåverkan. En känslighetsanalys visade att valet av VIP:ar har en betydande inverkan på miljöpåverkan, vilket ger möjlighet att reducera den totala användningen av primärenergi i en byggnad med 12 % och utsläppen av växthusgaser kan vara minska, så mycket som 11 % när det gäller både produktion och drift under 50 år. Avslutningsvis är det möjligt att dra slutsatsen att VIP:ar är ett mycket konkurrenskraftigt alternativ för att isolera byggnader som är typiska för Miljonprogrammet. Dock krävs ytterligare undersökningar för att minimera de mätbara miljöeffekter som förvärvats i denna LCA-studie för VIP-isolerade byggnader. / <p>QC 20151109</p> / Simulations of heat and moisture conditions in a retrofit wall construction with Vacuum Insulation Panels / Textural and thermal conductivity properties of a low density mesoporous silica material / A study of the thermal conductivity of granular silica materials for VIPs at different levels of gaseous pressure and external loads / Evaluation of the thermal conductivity of a new nanoporous silica material for VIPs – trends of thermal conductivity versus density / A comparative study of the environmental impact of Swedish residential buildings with vacuum insulation panels / ETICS with VIPs for improving buildings from the Swedish million unit program “Miljonprogrammet”

Page generated in 0.1152 seconds