• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de metodologia para determinação simultanea, por CLAE das vitaminas B1, B2, B6, acido nicotinico e nicotinamida em alimentos enriquecidos

Agostini, Tania da Silveira 27 November 1993 (has links)
Orientador: Helena Teixeira Godoy / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-21T19:48:25Z (GMT). No. of bitstreams: 1 Agostini_TaniadaSilveira_D.pdf: 5883887 bytes, checksum: 380aa123d267aa6305fad8a44ef8249a (MD5) Previous issue date: 1996 / Resumo: O controle dos níveis de enriquecimento de alimentos, pela adição de vitaminas, tem sido dificultado, especialmente, pela falta de metodologias apropriadas. Visando suprir esta deficiência, foi desenvolvida e. avaliada uma metodologia para determinação simultânea das vitaminas B1, B2, B6, ácido nicotínico e nicotinamida em alimentos enriquecidos, utilizando a cromatografia líquida de alta eficiência (CLAE). O método desenvolvido foi aplicado na determinação dessas vitaminas em 50 diferentes tipos/marcas de alimentos enriquecidos, como biscoitos de maisena (marca comercial grafada com Z, registrada), de leite, maria, coco e recheados, farinhas de cereais, farinhas lácteas, flocos de milho, macarrões, bebidas lácteas aromatizadas, leite em pó e esterilizado, bebida dietética e um complemento alimentar para desenvolvimento de massa muscular. As vantagens do método proposto, em relação aos métodos oficiais, são, além da determinação simultânea de 4 vitaminas (Bl, B2, B6 e PP, incluindo as duas formas desta última, ácido nicotínico e nicotinamida), simplicidade e versatilidade das etapas de extração e limpeza, utilização de reagentes com menores níveis de toxicidade, uso de detector UV, em substituição ao de fluorescência, eliminação de reações de derivação e rapidez. A extração multivitamínica é feita com ácido sulfúrico diluído, através de vibração ultra-sônica. A precipitação do extrato com metanol, seguida de refrigeração, é satisfatória tanto na eliminação de interferentes, quanto na prevenção de precipitação na coluna cromatográfica. A eluição por gradiente é importante para a obtenção de boa resolução das vitaminas, sendo que todas as vitaminas são eluídas em 23 min de corrida. O tempo necessário para o re-equilíbrio da coluna é de 20 mino A detecção é feita na região do ultravioleta e a quantificação é feita por curvas de padronização externa. Os limites de detecção e recuperação, nos níveis médios de enriquecimento, foram, respectivamente, 0,04 µg/ml e 102% para a vitamina B1, 0,03 µg/ml e 96% para a B2, 0,08 µg/ml e 106% para a B6, 0,10 µg/ml e 105% para a nicotinamida e 0.03 µg/ml e 81% para o ácido nicotínico. Os testes de repetibilidade, nos níveis de enriquecimento, apresentaram um coeficiente de variação médio inferior a 5% para as vitaminas B1, B2 e nicotinamida, inferior a 10% para a vitamina B6 e inferior a 13% para o ácido nicotínico. Entre os alimentos enriquecidos analisados, todos os diferentes tipos de biscoitos, de 1 única marca, apresentaram apenas 30 % dos valores de vitamina B2 descritos nas embalagens dos produtos; os flocos de milho, de 4 diferentes marcas, apresentaram menos de 30% dos níveis vitamínicos declarados; macarrões, de 1 única marca, não apresentaram nenhuma das vitaminas descritas nas embalagens do produto e o complemento alimentar para desenvolvimento de massa muscular apresentou níveis de B1, B2 e nicotinamida superiores a 300% dos valores declarados. Menores variações também foram observadas em alguns dos outros produtos analisados. Os resultados obtidos neste trabalho, além de demonstrarem as vantagens e aplicabilidade da metodologia desenvolvida, apontam para a necessidade de maior rigor no controle das taxas de enriquecimento destes alimentos. / Abstract:The control of enrichment levels in foods is difficult mainly due to the lack of appropriate analytical methodology. A new method for the simultaneous determination of nicotinamide, nicotinic acid, ribotlavin, thiamin and pyridoxine in enriched Brazilian foods by high performance liquid chromatography (HPLC) was developed and evaluated. The new method was employed to determine the vitamin B group in a survey of fifty products, such as cornflour, milk, coconut and sandwich biscuits, cereal flour, lacteous flours, com flakes, macaroni, flavored milk, whole and skim milk powder, acidified milk powder, steritized whole milk, flavored diet drinks and flavored mix for milk-based diet drink. In addition to the simultaneous determination of four vitamins (Bl, B2, B6 and two diferent forms of PP), the advantages of the method developed are: simplicity and improvement in the extraction and cleaning procedures, no use of toxic reagents, use of the UV detector instead of the fluorescent detector, elimination of derivatization reactions and speed in comparison with the official methods. The multivitamin extraction with sulfuric acid in an ultrasonic wave vibrator proved effective. The methanol solution provided partial purification of the extract and prevented precipitation on the analytical column. Neverthless, a gradient elution was necessary in order to get good resolution of the compounds. As the amounts of vitamins in enriched foods are normally greater than usual, the detection can be made using a UV detector. Quantitative data were obtained using calibration curves constructed by plotting peak area versus concentration. Quantification limits of the method and recoveries, in average enrichment levels, were 0.04 µg/ml and 102% for vitamin B1, 0.03 µg/ml and 96% for B2, 0.08 µg/ml and 106% for B6, 0.10 µg/ml and 105% for nicotinamide and 0.03 µg/ml and 81% for nicotinic acid, respectively. Repeated.injections showed a relative standard deviation lower than 5% for vitamin B1, B2 and nicotinamide, 10% for vitamin B6 and 13% for nicotinic acid, respectively. In some of the products analized the vitamin levels agreed with those printed on the package. Although some slight quantitative variations were found within biscuits, one sample had levels of ribot1avin 35% lower than the value stated on the package. Of five different com cereal brands, only one had the declared vitamin content, the others were 30% lower. No B-group vitamins were detected in one brand of enriched macaroni, except for the nicotinic acid naturally present in the t1om. On the other hand, one t1avored milk drink exhibited vitamins levels 200% higher than the amounts stated on the label and one milk drink mix had thiamin, ribot1avin and nicotinamide levels 3 to 5 times greater than stated. These results suggest an absence of control of the amount of vitamins in enriched foods. / Doutorado / Doutor em Ciência de Alimentos
2

Contribuição ao estudo do acido folico em alimentos enriquecidos

Pallone, Juliana Azevedo Lima, 1977- 28 July 2018 (has links)
Orientador: Helena Teixeira Godoy / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-28T11:48:16Z (GMT). No. of bitstreams: 1 Pallone_JulianaAzevedoLima_M.pdf: 19998225 bytes, checksum: a7769925437b6605ba41d30f7837959c (MD5) Previous issue date: 2001 / Resumo: Mesmo com o grande impacto causado pelos resultados das novas pesquisas a respeito das possíveis ações benéficas do ácido fólico à saúde, ainda são muito poucos os dados a respeito dos reais teores de ácido fólico, presente nos alimentos, principalmente dados analíticos sobre alimentos brasileiros, como também dados de estabilidade. A população está, portanto, exposta ao consumo de alimentos de qualidade não controlada, podendo ingerir quantidades não adequadas, às necessidades. Na tentativa de melhorar esse quadro é que este trabalho foi conduzido. Utilizou-se a cromatografia líquida de alta eficiência (CLAE) para determinação de ácido fólico segundo CATHARINO e GODOY (2000). O método foi aplicado em amostras de leite esterilizado, produzido em planta piloto e também adquirido no mercado, leite em pó, bebida láctea achocolatada pronta para consumo, margarina, farinha e pão. Pequenas adaptações na metodologia foram feitas, principalmente na etapa de extração, para amostras de farinha e pão. A aplicação da metodologia para margarina, assim como as alterações no método para as amostras de farinha e pão foram validadas em relação à recuperação, repetibilidade, limites de detecção e quantificação obtendo valores em torno de 96% de recuperação, coeficientes de variação inferiores a 1,5% nos ensaios de repetibilidade e 1,3ng/mL e 2,6ng/mL os limites de detecção e quantificação determinados, respectivamente. Foram analisadas 4 amostras, em 3 diferentes lotes, de leites fluídos adquiridos no mercado, com datas bem próximas ao processamento, e o valor do ácido fólico encontrado estava abaixo do declarado no rótulo do produto, para 50% das amostras analisadas. Após 3 meses, ainda dentro do prazo de validade, a perda de ácido fólico chegou a 20%. Nos 4 ensaios de esterilização do leite, realizado em planta piloto, nos processos de adição e homogeneização a perda de ácido fólico ficou em torno de 54%, enquanto que o processo de esterilização foi responsável por uma perda de apenas 10%. Durante o período de 90 dias a taxa de ácido fólico perdida foi de 16% Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital. / Abstract: Despite the great impact of the results of new research in to possible beneficial effects of folic acid on the health, there are still not enough data about the content of folic acid in enriched food and no studies on its stability, chiefly in Brazilian foods. Therefore people are exposed to the consumption of food of uncontrolled quality, ingesting inadequate quantities for their needs. The aim of this work was to improve this picture. High pressure liquid chromatography (HPLC) was used to determine folic acid according to CATHARINO and GODOY (2000), in samples of sterilized milk produced in a pilot plant and also in samples purchased on the market, in powdered milk, ready to use milk chocolate beverage, margarine, flour and bread. Some modifications in the methodology wêre made, mainly in the extraction step, for the samples of flour and bread. These alterations were validated with respect to recover, and values of from 92 to 98% were obtained, repeatability was very well. The limits of detection and quantification being respectively 1,3ng/mL and 2,6ng/mL. Four sample were analysed in 3 different lots of fluid milk purchased on the market, and the values of folic acid were found to be below the values declared on the label of the products, in 50% of the samples. After 3 months, the loss of folic acid approached 20%. In all the 4 experiments with milk sterilization made in the pilot plant, the process of addition and homogenization resulted in a loss of folic acid of 54%, while the process of sterilization was responsible for only 10%. In a 90-day period the loss of folic acid was 16%. The same milk samples were submitted to a boiling process and the vitamin was show to be resistant, with a conservation of about 99%. As for powdered milk and ready to use milk chocolate beverage, 4 samples of each were also analysed, in 3 different lots, for each product purchased on the market. The content of folic acid found was practically equal that declared by.the manufacturers for the powdered milk. Nevertheless, after 1 year of storage, the loss of folic acid reached 60% ...Note: The complete abstract is available with the full electronic digital thesis or dissertations. / Mestrado / Mestre em Ciência de Alimentos

Page generated in 0.0536 seconds