On impacts and ride-through of voltage sags exposing line-operated AC-machines and metal processesCarlsson, Fredrik January 2003 (has links)
During the last decade, power quality has been recognised asa global problem. Among different types of power qualityproblems, voltage sags have been identified to be one of themost severe problems for different process industries. The mostcommon reason to voltage sags is lightning strikes in powerlines. Protection equipment, usually located at switchyards,disconnect faulted power lines as soon as possible, which isapproximately 100 ms. Thus, the duration of voltage sags areapproximately 100 ms. The sensitivity to voltage sags ofelectrical equipment in process industries can be observed asfor instance malfunction, automatic turnoff or damages. This thesis gives an overview of three metals processes withfocus on the sensitivity to voltage sags and interruptions. Theinherent energy in the process is used to find the sensitivity.This energy may also be used to obtain "ride-through" for theprocesses. The three metals processes are a blast furnaceprocess, a hot rolling mill process and a cold rolling millprocess. The main attention in this thesis is paid to the blastfurnace process, which is powered by a line-operatedsynchronous machine. The thesis shows that the protection equipment forelectrical machines can be adjusted to avoid unnecessaryshutdowns. It is also explained why there are high torque andcurrents during voltage sags as well as after voltage sags. Itis shown that the first peak torque and current during thevoltage sags is almost proportional to the voltage change, thatis the voltage magnitude before the voltage sag minus thevoltage magnitude during the voltage sag. The first peak torqueand current after the voltage sag depends sinusoidal-like onthe duration of the voltage sag and almost proportional to thevoltage change during the voltage sag. There is no fluxsaturation during voltage sags, however after voltage sagssaturation is very likely to occur. The thesis explains why andalso how the flux is changed during and after voltage sags. The duration of voltage sags is in many cases set by theprotection equipment located in switchyards. It is shown thatthe durations of voltage sags can be changed to durations thatwill cause less peak torque and current after voltage sags forline-operated AC-machines. It is also shown how this istheoretically achieved. <b>Keywords:</b>Rolling mill, Blast furnace, Power Quality,Synchronous machine, Asynchronous machine, Voltage sag, Voltageinterruption, Ride-through, Process disturbances, Simulation,Modelling
|
2 |
On impacts and ride-through of voltage sags exposing line-operated AC-machines and metal processesCarlsson, Fredrik January 2003 (has links)
<p>During the last decade, power quality has been recognised asa global problem. Among different types of power qualityproblems, voltage sags have been identified to be one of themost severe problems for different process industries. The mostcommon reason to voltage sags is lightning strikes in powerlines. Protection equipment, usually located at switchyards,disconnect faulted power lines as soon as possible, which isapproximately 100 ms. Thus, the duration of voltage sags areapproximately 100 ms. The sensitivity to voltage sags ofelectrical equipment in process industries can be observed asfor instance malfunction, automatic turnoff or damages.</p><p>This thesis gives an overview of three metals processes withfocus on the sensitivity to voltage sags and interruptions. Theinherent energy in the process is used to find the sensitivity.This energy may also be used to obtain "ride-through" for theprocesses. The three metals processes are a blast furnaceprocess, a hot rolling mill process and a cold rolling millprocess. The main attention in this thesis is paid to the blastfurnace process, which is powered by a line-operatedsynchronous machine.</p><p>The thesis shows that the protection equipment forelectrical machines can be adjusted to avoid unnecessaryshutdowns. It is also explained why there are high torque andcurrents during voltage sags as well as after voltage sags. Itis shown that the first peak torque and current during thevoltage sags is almost proportional to the voltage change, thatis the voltage magnitude before the voltage sag minus thevoltage magnitude during the voltage sag. The first peak torqueand current after the voltage sag depends sinusoidal-like onthe duration of the voltage sag and almost proportional to thevoltage change during the voltage sag. There is no fluxsaturation during voltage sags, however after voltage sagssaturation is very likely to occur. The thesis explains why andalso how the flux is changed during and after voltage sags.</p><p>The duration of voltage sags is in many cases set by theprotection equipment located in switchyards. It is shown thatthe durations of voltage sags can be changed to durations thatwill cause less peak torque and current after voltage sags forline-operated AC-machines. It is also shown how this istheoretically achieved.</p><p><b>Keywords:</b>Rolling mill, Blast furnace, Power Quality,Synchronous machine, Asynchronous machine, Voltage sag, Voltageinterruption, Ride-through, Process disturbances, Simulation,Modelling</p>
|
3 |
Parametrizace mezních křivek odolnosti elektrických spotřebičů na krátkodobé poklesy a výpadky napětí / Parameterization of electric appliances immunity curves to voltage dips and short interruptionsŠlezingr, Jan January 2008 (has links)
This master’s thesis work deal with diagnosis parameters immunity curves uniphase appliance on short - term voltage dips a interuption. Immunity curve is dependence smallest possible sizes RMS voltage for performance given to criteria function on time continuation voltage event. Curves of resistance is different for each electric appliance, and depending on the size and over-voltage network, the burden on resources and voltage during the event.. The goal of this work is to devise a methodology for measuring the implementation of parametric measurement limit curves of resistance for selected types of appliances.
|
4 |
Odolnost spotřebičů na krátkodobé poklesy a výpadky napětí / The Appliances Immunity to Short Voltage Dips and InterruptionsBok, Jaromír January 2011 (has links)
This Ph.D. thesis deals with problems about voltage dips and short voltage interruptions, generally named as voltage events, which origin in power supply networks and have a negative influence for all connected electric appliances. In this thesis single phase appliances are considered. These problems closely relate with area of electromagnetic compatibility which solve all questions about correct operation of different types of electric appliances during electromagnetic disturbances impact. Voltage events are ones of the many types of electromagnetic disturbances. The connection between disturbance sources and sensitive electric appliances is created by power supply lines. The immunity of electric appliances to voltage dips and short interruptions is currently tested via voltage dips with strictly defined parameters which are intended by class of electromagnetic environment in which the usage of electric appliance is recommended. During immunity tests the rectangular shape of voltage dips is preferred. The main descriptive parameters of testing voltage events are the residual voltage and the event time duration. But voltage dips and short interruptions defined by this way do not closely relate with parameters of real voltage dips and interruptions occurred in public supply system where parameters of voltage dips are variable. Moreover in the power supply system there are many of others voltage parameters which can have a significant influence to immunity level of connected electric appliances. This Ph.D. thesis also deals with finding more voltage event parameters. Although the voltage events occurrence in the power supply system is not limited and voltage events are considered only as informative voltage parameter it is important to monitor voltage events occurrence. The monitoring device has to be able to operate for ling time period and it has to detect parameters of voltage events with adequate accuracy. The accuracy of detected event parameters and the detection delay depends on the detection algorithm characteristics. That is why the part of this thesis relates with a comparison of several detection algorithms and their abilities to correct detection of voltage event parameters. The main purpose of this thesis is the proposal of connection between classification of voltage dips and short interruptions occurred in power supply system with the classification of electric appliances immunity to these voltage events. On the base of many of provided electric appliances immunity tests and also on the base of long time period voltage events monitoring the special compatibility levels are proposed in this thesis. The observation of proposed compatibility levels will bring the increasing level of reliable operation of all connected electric appliances.
|