• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica empregando eletrodos de ouro / Manganese determination in cement and clinker samples by cathodic stripping voltammetry using gold electrodes

Joca, Jhonny Frank Sousa 22 June 2011 (has links)
Este trabalho apresenta o desenvolvimento e a aplicação de um método alternativo para determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica por onda quadrada empregando eletrodos de ouro. Após estudos exploratórios acerca do comportamento eletroquímico do manganês no eletrólito suporte H3BO3 0,20 mol L-1 / KCl 0,10 mol L-1 com pH 6,5 e a otimização dos parâmetros operacionais para a voltametria de onda quadrada, foram obtidos excelentes resultados na determinação de manganês nas amostras analisadas. Destacam-se a ótima linearidade, verificada em duas faixas distintas de concentração, e os baixos limites de detecção e quantificação obtidos (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectivamente), além da concordância entre os resultados obtidos pela técnica eletroanalítica quando comparados aos resultados fornecidos pela espectrometria de absorção atômica de chama (FAAS). Para o tratamento das amostras foi avaliada a eficiência da extração ácida assistida por ultrassom. Foram avaliados ácidos minerais individualmente (HCl, H2SO4 e HClO4 em diferentes concentrações), em mistura ou ainda associados a H2O2. Os melhores resultados foram obtidos utilizando uma solução de HCl 3 mol L-1, que extraiu quantitativamente o manganês nas amostras analisadas. Os resultados obtidos foram concordantes com a metodologia padrão utilizada para a abertura da amostra e posterior análise por espectrometria de absorção atômica de chama, que emprega o aquecimento em chapa e a mesma solução extratora. / This work describes the development and application of a new alternative method for determination of manganese in cement and clinker samples by square wave cathodic stripping voltammetry using gold electrodes. After exploratory studies on the electrochemical behavior of manganese in H3BO3 0.20 mol L-1 / KCl 0.10 mol L-1 supporting electrolyte at pH 6.5 and the optimization of operating parameters for the square wave voltammetry, excellent results were obtained for determination of manganese in the samples analyzed. Most notable are the excellent linearity, verified in two distinct concentration bands and the low limits of detection and quantification obtained (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectively), in addiction to the concordance between the obtained results by the electroanalytical technique when compared to the provided by the flame atomic absorption spectrometry. For samples treatment were tested the efficiency of the ultrasound-assisted extraction. Were evaluated individually mineral acids (HCl, H2SO4 and HClO4 at different concentrations) in a mixture or associated with H2O2. the best results were obtained using a 3 mol L-1 HCl solution, which extracted manganese quantitatively from the analysed samples, in comparison to the standard method for extraction, targeting a later atomic absorption flame spectrometry analysis, which uses the plate heating and the same extracting solution. The obtained results for the analysed samples agrees with the cement and clinker samples of the used literature
2

Determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica empregando eletrodos de ouro / Manganese determination in cement and clinker samples by cathodic stripping voltammetry using gold electrodes

Jhonny Frank Sousa Joca 22 June 2011 (has links)
Este trabalho apresenta o desenvolvimento e a aplicação de um método alternativo para determinação de manganês em amostras de cimento e clínquer por voltametria de redissolução catódica por onda quadrada empregando eletrodos de ouro. Após estudos exploratórios acerca do comportamento eletroquímico do manganês no eletrólito suporte H3BO3 0,20 mol L-1 / KCl 0,10 mol L-1 com pH 6,5 e a otimização dos parâmetros operacionais para a voltametria de onda quadrada, foram obtidos excelentes resultados na determinação de manganês nas amostras analisadas. Destacam-se a ótima linearidade, verificada em duas faixas distintas de concentração, e os baixos limites de detecção e quantificação obtidos (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectivamente), além da concordância entre os resultados obtidos pela técnica eletroanalítica quando comparados aos resultados fornecidos pela espectrometria de absorção atômica de chama (FAAS). Para o tratamento das amostras foi avaliada a eficiência da extração ácida assistida por ultrassom. Foram avaliados ácidos minerais individualmente (HCl, H2SO4 e HClO4 em diferentes concentrações), em mistura ou ainda associados a H2O2. Os melhores resultados foram obtidos utilizando uma solução de HCl 3 mol L-1, que extraiu quantitativamente o manganês nas amostras analisadas. Os resultados obtidos foram concordantes com a metodologia padrão utilizada para a abertura da amostra e posterior análise por espectrometria de absorção atômica de chama, que emprega o aquecimento em chapa e a mesma solução extratora. / This work describes the development and application of a new alternative method for determination of manganese in cement and clinker samples by square wave cathodic stripping voltammetry using gold electrodes. After exploratory studies on the electrochemical behavior of manganese in H3BO3 0.20 mol L-1 / KCl 0.10 mol L-1 supporting electrolyte at pH 6.5 and the optimization of operating parameters for the square wave voltammetry, excellent results were obtained for determination of manganese in the samples analyzed. Most notable are the excellent linearity, verified in two distinct concentration bands and the low limits of detection and quantification obtained (3,1 x 10-8 mol L-1 e 9,8 x 10-8 mol L-1, respectively), in addiction to the concordance between the obtained results by the electroanalytical technique when compared to the provided by the flame atomic absorption spectrometry. For samples treatment were tested the efficiency of the ultrasound-assisted extraction. Were evaluated individually mineral acids (HCl, H2SO4 and HClO4 at different concentrations) in a mixture or associated with H2O2. the best results were obtained using a 3 mol L-1 HCl solution, which extracted manganese quantitatively from the analysed samples, in comparison to the standard method for extraction, targeting a later atomic absorption flame spectrometry analysis, which uses the plate heating and the same extracting solution. The obtained results for the analysed samples agrees with the cement and clinker samples of the used literature
3

COMPARAÇÃO DE SENSORES ELETROQUÍMICOS PARA DETERMINAÇÃO DE ENXOFRE EM BIODIESEL / COMPARISON OF ELECTROCHEMICAL SENSORS FOR DETERMINATION OF SULPHUR IN BIODIESEL

Costa, Helmara Diniz 06 June 2013 (has links)
Made available in DSpace on 2016-08-19T12:56:46Z (GMT). No. of bitstreams: 1 Dissertacao Helmara.pdf: 1239564 bytes, checksum: f5a4e670235603269ce13bb3db2a2938 (MD5) Previous issue date: 2013-06-06 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Due to the implementation of more restricted environmental regulation laws, the control of pollution agent such as sulfur compounds has provides the development of new analytic methodologies for its quantification on different matrices, including biodiesel fuel. Thus, this work aims to compare three different sensors - film bismuth and mercury film on the surface of a glassy carbon electrode and solid silver amalgam (dental) - for the determination of sulfur in biodiesel, by means of stripping voltammetric cathodic square wave mode (VRC/SW) as supporting electrolyte with a solution of sodium acetate (1,4 mol.Lˉ¹) and acetic acid (0.33 mol.Lˉ¹) in metanol/2-propanol. In general, the mercury film electrode (MFE) has presented the best electrochemical behavior to the definition of peak reduction, being then selected as standard electrode to the measurements. The sulfur quantization on biodiesel samples was performed by adding 70 μL of soybean biodiesel and tallow fatty with TMAH, adding later, aliquots of standard sulfur. The method showed good linearity (0.998), suggesting an average sulfur concentration of 6,870x10ˉ7 (± 6,857x10ˉ⁸) mol.Lˉ¹, within a confidence interval of 95%, to a limit of detection 3,294x10ˉ¹º mol.Lˉ¹ and quantification limit of 1,098x10ˉ9 mol.Lˉ¹. Besides, for the untreated sample, the experimental has provided a LD of 6,54 x 10ˉ9 mol.Lˉ¹. Finally the proposed method has been compared with the results of a collaborative study (ANP 01/2012) of the same sample using the Teste-t de Student, verifying that the proposed method and official methods (EN ISO 20846, EN ISO 20884) are statistically equivalent to a confidence level of 95%, thereby demonstrating the feasibility of the method. / O controle da poluição ambiental tem exigido, cada vez mais, a determinação de enxofre em uma variedade de matrizes. Diferentes métodos analíticos têm sido desenvolvidos para determinação deste analito em biodiesel, empregando várias técnicas, que vão desde a análise cromatográfica aos métodos espectroanalíticos. No presente trabalho são apresentados os resultados da avaliação de diferentes sensores eletroquímicos para determinação de enxofre em Biodiesel, utilizando a técnica voltamétrica de redissolução catódica no modo onda quadrada (VRC/SW) tendo como eletrólito suporte uma solução de acetato de sódio (1,4 mol.Lˉ¹) e ácido acético (0,33 mol.Lˉ¹), em metanol/2-propanol. Foram avaliados três sensores (filme de bismuto e filme de mercúrio na superfície de carbono vítreo, e eletrodo sólido de amálgama de prata dentária) na determinação de enxofre, sendo observado que o eletrodo de filme de mercúrio (EFM) apresentou os melhores resultados relacionados ao comportamento eletroquímico na definição do pico de redução. Portanto, o EFM foi o sensor escolhido para aplicação na amostra de biodiesel. A determinação do analito em Biodiesel foi realizada adicionando-se 70 μL de Biodiesel de Soja e Sebo (01/2012, interlaboratorial) tratado com TMAH, adicionando, posteriormente, alíquotas de padrão de enxofre. O método apresentou uma boa linearidade (0,998), determinando-se assim uma concentração média de enxofre de 3,687 x 10ˉ7± 6,857 x 10ˉ⁸ mol.Lˉ¹, a um intervalo de confiança de 95%, para um limite de detecção de 3,294 x 10-10 mol.Lˉ¹ e limite de quantificação de 1,098 x 10ˉ9 mol.Lˉ¹, o que demonstra uma boa sensibilidade da técnica. Além disso, avaliou-se o estudo sem tratamento da amostra, na qual obteve-se LD de 6,54 x 10ˉ9 mol.L-1. O presente método foi comparado com os resultados de um estudo interlaboratorial (ANP 01/2012) da mesma amostra, utilizando o Teste-t de Student, verificando que o método proposto e os métodos oficiais (EN ISO 20846; EN ISO 20884) são estatisticamente equivalentes a um nível de confiança de 95%, demonstrando assim a viabilidade do método.

Page generated in 0.1056 seconds