• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 16
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Attityder till kvinnliga chefer

Wallström, Astrid January 2011 (has links)
Ojämställdhet råder, framför allt inom det privata näringslivet, på chefsnivå i Sverige. Majoriteten av samtliga chefer män, endast 33 % av cheferna är kvinnor. Inom den privata sektorn är andelen kvinnliga chefer endast 25 %, medan det inom den offentliga sektorn råder det omvända; 64% av cheferna inom den kommunala sektorn är kvinnor, i landstingen är andelen 72%. Tidigare forskning har visat att de stereotypa attityder som finns avseende kvinnliga chefer påverkar kvinnors karriärmöjligheter. Föreliggande studie syftade därför till att undersöka vilka attityder som finns avseende kvinnliga chefer och om det finns någon skillnad i attityder beroende på respondentens karaktäristika. Studien omfattade 57 deltagare och genomfördes med hjälp av Women As Managers Scale (WAMS). Signifikanta skillnader i attityd till kvinnliga chefer uppvisades på basis av respondentens kön, akademiska bakgrund och erfarenhet av kvinnliga chefer. Inga signifikanta skillnader mellan den yngre och äldre respondentgruppen uppvisades. Studien visade därmed att det inte är rimligt att anta att ett generationsskifte på arbetsmarknaden kommer att förändra attityderna till kvinnliga chefer. De respondenter som hade negativa attityder till kvinnliga chefer ansåg att det är större skillnad mellan kvinnliga och manliga chefer än de respondenter som hade positiva attityder till kvinnliga chefer.
2

Indice de detección de problemas de estabilidad de tensión en base a WAMS

Arias Cazco, Diego Anibal January 2012 (has links)
Magíster en Ciencias de la Ingeniería, Mención Eléctrica / En la actualidad los sistemas eléctricos de potencia a menudo operan bajo condiciones de estrés, para satisfacer una demanda que es cada vez mayor, con una expansión de la red de transmisión relativamente limitada. Esto genera la necesidad de utilizar nuevos recursos de equipos, metodologías de análisis y herramientas computacionales para hacer frente a esta situación. En particular, la estabilidad de tensión ocupa un lugar preponderante dentro de los nuevos fenómenos que ponen en riesgo la seguridad del sistema, por ello reviste gran importancia el uso de indicadores que alerten de manera temprana sobre la posible ocurrencia de fenómenos que pudieran derivar en un colapso de tensión en la red. En este campo uno de los avances más promisorios es el uso de mediciones sincronizadas entregadas por los llamados Sistemas de Medición de Área Amplia (Wide Area Measurement Systems, WAMS en inglés), quienes obtienen la información de entrada para los indicadores de estabilidad de tensión en base a PMU (Phasor Measurement Unit). Al revisar el estado del arte en relación a estos índices de detección de estabilidad de tensión en tiempo real, se constata que la mayoría de los estudios e investigaciones evalúan los márgenes de estabilidad de tensión en el punto crítico (punta de la curva nariz), es decir, detectando la distancia al punto teórico de máxima transferencia de potencia del sistema. Este tipo de métodos, pueden llevar a análisis imprecisos ya que en el punto de máxima transferencia los niveles de tensión llegan a valores muy inferiores a los límites operacionales reales por lo que en la práctica se podría llegar a una situación de colapso de tensión sin ser detectado por esos indicadores. Por otra parte, para tener un análisis completo no basta con determinar la máxima trasferencia de potencia por el sistema de transmisión, sino que se debe verificar que el sistema tenga además los medios para proveer la cantidad de reactivos que dicha transferencia y carga requieren. Considerando que la estimación de estado en base a mediciones sincronizadas está disponible, este trabajo de investigación se dirige hacia el desarrollo de una mejora en la línea de índices de estabilidad de tensión usando dichas mediciones. Se propone un indicador llamado VSI-OC (Voltage Stability Index under Operational Conditions), el cual considera límites reales de operación y una evaluación de las reservas de reactivos del sistema. El indicador se obtiene de un problema de optimización propuesto, en el cual, se define el máximo incremento de carga en la barra como función objetivo, tomando como restricciones de igualdad las ecuaciones de flujo de potencia, y como restricciones de desigualdad los límites de reactivos de generación. Especialmente, el indicador considera límites de tensión de acuerdo a exigencias operativas, es decir, los estipulados en las respectivas normas técnicas. Para validar el método propuesto, se aplica a una simulación en un modelo del SIC de 114 barras, en el cual, se prueba el desempeño del índice propuesto bajo diferentes escenarios con el objeto de abordar un amplio espectro de estados de operación. Los índices cuantifican la seguridad del sistema en una escala de 0 a 1 , en donde, un valor cercano a 1 indica que la barra de carga dispone de un buen margen de estabilidad y un valor cercano a 0 indica que la barra esta cerca a violar los límites operacionales del sistema. Los resultados indican que el método cumple con el objetivo propuesto, permitiendo monitorear adecuadamente la proximidad de eventos que pueden derivar en un colapso de tensión. El índice VSI-OC da señales de alerta con mayor anticipación que los índices convencionales. De esta manera, el operador puede realizar una asignación de recursos de potencia reactiva en forma óptima y tomar las acciones de control necesarias para mantener el sistema en condiciones de operación normal, permitiendo una operación segura. Como trabajo futuro se propone extender la investigación a aplicaciones en tiempo real en base a WAMS, y enfrentar los mayores retos en el desarrollo de estas tecnologías, tales como manejo de congestiones en la red, control de flujos en tiempo real, control y protección en sistemas de área amplia (WAMPAC en inglés).
3

Attityder till kvinnligt och manligt ledarskap : - stereotyper och fördomar bland poliser och sjuksköterskor / Attitudes towards female and male leadership : – stereotypes and prejudice’s among polices and nurses

Maghdoori, Leily January 2007 (has links)
<p>En mängd forskning har gjorts kring kvinnors hinder att nå chefspositioner och vilka fördomar kvinnliga chefer möter. Många studier visar att fördomar bottnar i bristande överensstämmelse mellan den kvinnliga könsrollen och ledarskapsrollen. Syftet med studien (n = 683) var att undersöka attityder till ledarskap och jämföra hur män och kvinnor inom två könssegregerade yrkesgrupper, sjuksköterskor och poliser, attribuerar manliga respektive kvinnliga egenskaper till ledaregenskaper. Hypoteserna baserades bland annat</p><p>på social identitetsteori. Resultatet visade att bägge yrkesgrupper förknippade framgångsrikt ledarskap med både kvinnliga och manliga egenskaper. Dock var sjuksköterskors skattning av kvinnliga egenskaper kontra ledaregenskaper högre än deras skattning av manliga egenskaper i förhållande till ledaregenskaper. Signifikant högre grad av fördomsbenägenhet gentemot kvinnliga ledare kunde påvisas bland poliserna.</p> / <p>It has been shown that barriers and prejudice’s impede women’s progress to managerial levels. Studies show that prejudice’s derives from perceived sextyping of the managerial role. The aim of the present (n = 683) study was to examine attitudes towards leadership and compare how men and women within two gender segregated occupational groups, nurses and polices, attributes male and female characteristics to successful management. The hypotheses were based on social identity theory. Results revealed that both occupational groups associate successful management with both male and female characteristics. However, nurses’ valuation of female characteristics counter managerial characteristics was higher than their valuation of male characteristics versus managerial characteristics. A significant higher level of prejudice towards female leaders was found among polices.</p>
4

On monitoring methods and load modeling to improve voltage stability assessment efficiency

Genêt, Benjamin 02 October 2009 (has links)
Power systems must face new challenges in the current environment. The energy market liberalization and the increase in the loading level make the occurrence of instability phenomena leading to large blackouts more likely. Existing tools must be improved and new tools must be developed to avoid them. The aim of this thesis is the improvement of the voltage stability assessment efficiency. Two orientations are studied: the monitoring methods and the load modeling. The purpose of the monitoring methods is to evaluate the voltage stability using only measurements and without running simulations. The first approach considered is local. The parameters of the Thevenin equivalent seen from a load bus are assessed thanks to a stream of local voltage and current measurements. Several issues are investigated using measurements coming from complete time-domain simulations. The applicability of this approach is questioned. The second approach is global and uses measurements acquired by a Wide-Area Measurement System (WAMS). An original approach with a certain prediction capability is proposed, along with intuitive visualizations that allow to understand the deterioration process leading to the collapse. The load modeling quality is certainly the weak point of the voltage security assessment tools which run simulations to predict the stability of the power system depending on different evolutions. Appropriate load models with accurate parameters lead to a direct improvement of the prediction precision. An innovative procedure starting from data of long measurement campaigns is proposed to automatically evaluate the parameters of static and dynamic load models. Real measurements taken in the Belgian power system are used to validate this approach.
5

Attityder till kvinnligt och manligt ledarskap : - stereotyper och fördomar bland poliser och sjuksköterskor / Attitudes towards female and male leadership : – stereotypes and prejudice’s among polices and nurses

Maghdoori, Leily January 2007 (has links)
En mängd forskning har gjorts kring kvinnors hinder att nå chefspositioner och vilka fördomar kvinnliga chefer möter. Många studier visar att fördomar bottnar i bristande överensstämmelse mellan den kvinnliga könsrollen och ledarskapsrollen. Syftet med studien (n = 683) var att undersöka attityder till ledarskap och jämföra hur män och kvinnor inom två könssegregerade yrkesgrupper, sjuksköterskor och poliser, attribuerar manliga respektive kvinnliga egenskaper till ledaregenskaper. Hypoteserna baserades bland annat på social identitetsteori. Resultatet visade att bägge yrkesgrupper förknippade framgångsrikt ledarskap med både kvinnliga och manliga egenskaper. Dock var sjuksköterskors skattning av kvinnliga egenskaper kontra ledaregenskaper högre än deras skattning av manliga egenskaper i förhållande till ledaregenskaper. Signifikant högre grad av fördomsbenägenhet gentemot kvinnliga ledare kunde påvisas bland poliserna. / It has been shown that barriers and prejudice’s impede women’s progress to managerial levels. Studies show that prejudice’s derives from perceived sextyping of the managerial role. The aim of the present (n = 683) study was to examine attitudes towards leadership and compare how men and women within two gender segregated occupational groups, nurses and polices, attributes male and female characteristics to successful management. The hypotheses were based on social identity theory. Results revealed that both occupational groups associate successful management with both male and female characteristics. However, nurses’ valuation of female characteristics counter managerial characteristics was higher than their valuation of male characteristics versus managerial characteristics. A significant higher level of prejudice towards female leaders was found among polices.
6

Esquema de detección de inestabilidad para operación en isla eléctrica utilizando sincrofasores

Arraño Vargas, Felipe Antonio January 2014 (has links)
Ingeniero Civil Eléctrico / En cualquier sistema eléctrico de potencia, sea éste complejo o no, existen perturbaciones o contingencias que pueden causar inestabilidad angular, de frecuencia y/o de tensión. El no poder recuperar el estado de equilibrio inicial se puede traducir en una segregación del sistema en dos o más partes, masivas pérdidas de suministro eléctrico o, lo que es peor aún, un apagón total. En los últimos años los sistemas de medición dinámica han experimentado un importante avance gracias a mediciones sincronizadas, éstas permiten adquirir varias muestras por segundo y proveer información coherente entre los ángulos de las medidas, haciéndolas comparables entre sí. Estas medidas otorgan información suficiente para evitar inestabilidades luego de ocurrida una perturbación, realizando acciones correctivas de protección sistémica tales como desprendimientos de carga, desprendimientos de generación y segregación en islas eléctricas de forma controlada. Considerando que esta tecnología puede ser aplicada en Chile, y particularmente en el sector sur del Sistema Interconectado Central (SIC), este trabajo propone un esquema de detección de inestabilidad para operación en isla eléctrica utilizando mediciones sincrofasoriales, con el objetivo de mantener el suministro eléctrico en la Isla Grande de Chiloé cuando el colapso del sistema es inminente luego de ocurrida una contingencia. El esquema verifica que tanto la diferencia angular, la primera y segunda derivada entre dos puntos del sistema permanezcan en una región estable o controlable. En caso de que alguna variable presente valores fuera de los límites establecidos se determina que el colapso del sistema es posible y que la segregación del sector seleccionado del resto de la red permitiría mantener el suministro eléctrico. Para la construcción de este esquema se simulan, en el software DIgSILENT y con la base del Centro de Despacho Económico de Carga (CDEC) del SIC actualizada a la fecha, tres contingencias reales y seis contingencias extremas para cuatro escenarios de operación. El esquema logra tener una exactitud de 88,9% y una sensibilidad de un 66,7% por otro lado, la operación en isla eléctrica sería posible en solo un escenario de operación, siendo necesaria la implementación de Esquemas de Desconexión de Carga y de Generación para que sea posible en otros dos.
7

Är chefen en kvinna? : Högskolestudenters attityder till kvinnor som chefer

Andersson, Ellen January 2017 (has links)
Forskning har länge bedrivits inom området gällande kvinnors hinder att nå högre chefspositioner. Könsroller, stereotypiska egenskaper, kategoriseringar och negativa attityder tycktes vara centrala i problematiken. Syftet med föreliggande studie var att undersöka hur högskolestudenter skattade sina attityder till kvinnor som chefer (n = 193, varav 124 kvinnor). En vinjettstudie med experimentell mellangruppsdesign genomfördes där materialet analyserades med tvåvägs ANOVOR för oberoende mätningar. Resultatet visade att kvinnliga högskolestudenter hade en signifikant mer positiv attityd till kvinnor som chefer jämfört med manliga högskolestudenter. Det påvisades även en signifikant skillnad i skattad attityd till kvinnor som chefer beroende på läst vinjett där kvinnliga högskolestudenter skattade kvinnor som chefer mer positivt efter att ha läst en vinjett om en kvinna som chef. Dock hade utbildning inom beteendevetenskapliga ämnen ingen signifikant inverkan på skattad attityd. Slutsatsen blev att kvinnor som chefer skattades mer positivt än förväntat, och att det tycks ha skett en attitydförändring.
8

Synchronized Phasor Measurement Units : Implementation of PMU Algorithm on HVDC Control Platform

Deo, Samarth January 2013 (has links)
Power Systems most often operate in the margins of stability limits. With power grids becoming even more automated now, Phasor Measurement Units (PMU’s) and Phasor Data Concentrators (PDC’s) become essential for real-time control of the system. Since PMU’s are time synchronized, the phasors can be compared at the substations, studied for any faults and analyzed at the same time. These PMU’s report the measured magnitude, phasor angle of voltages and currents in real synchronized time in different locations. One good way to measure these quantities is to use the Discrete Fourier Transform (DFT) and analyze the signal as a digital signal. However with transients and noise present in the input signal, DFT might not be the best approach for measurement and/or protection. With the IEEE C37.118 (Standard for Synchrophasor for Power Systems) 2011 version emphasizing on the importance of the two classes of PMU’s- P-class for Protection and M-class for Measurement; every vendor now has to label their products with one of these classes. There is a high precision required for P-class PMU’s whereas a good reporting rate for M-class. Recently The North-American Synchrophasor Initiative (NASPI) and Western Electricity Coordinating Council (WECC) also gave filtering specifications and frequency response of an industry compliant PMU. This thesis discusses the various frequency estimation algorithms, which are compliant with the NASPI/WECC standards. Further such an algorithm is implemented on ABB proprietary hardware and tested against dynamic tests.
9

Proposta e implementação de uma Micro-PMU

Aleixo, Renato Ribeiro 01 March 2018 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-04-10T14:04:24Z No. of bitstreams: 1 renatoribeiroaleixo.pdf: 11717772 bytes, checksum: 92418eff47ec8bfa0e099a19d849c068 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-04-10T14:22:50Z (GMT) No. of bitstreams: 1 renatoribeiroaleixo.pdf: 11717772 bytes, checksum: 92418eff47ec8bfa0e099a19d849c068 (MD5) / Made available in DSpace on 2018-04-10T14:22:50Z (GMT). No. of bitstreams: 1 renatoribeiroaleixo.pdf: 11717772 bytes, checksum: 92418eff47ec8bfa0e099a19d849c068 (MD5) Previous issue date: 2018-03-01 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho tem como objetivo a proposta de uma Unidade de Medição Fasorial (do inglês, Phasor Measurement Unit)(PMU), de baixo custo, voltada para o monito-ramento da distribuição de energia elétrica. O medidor proposto pode ser conectado à rede de baixa tensão, possibilitando assim o monitoramento dos sistemas de dis-tribuição e transmissão de energia. O algoritmo de estimação fasorial que compõe o software embarcado do equipamento faz uso do filtro Savitzky-Golay como aproxima-ção da derivada, necessária no processo de estimação da frequência do componente fundamental do sinal. O hardware utilizado é composto pelo microprocessador ARM TM4C1294NCPDT da Texas Instruments, um módulo GPS NEO-6M da uBlox, um módulo Wi-Fi ESP8266, além de um circuito de condicionamento do sinal analógico. O sincronismo das medições realizadas é garantido graças ao sinal composto por um pulso por segundo fornecido pelo GPS. Para o envio dos dados gerados pelo medidor pro-posto, o protocolo definido na norma vigente para PMUs foi utilizado. As estimações podem ser armazenadas e vizualizadas em tempo real através de um software monitor de dados de sincrofasores. Os resultados contemplam os testes exigidos pela norma, avaliando-se o erro total da estimação do fasor, o erro de frequência e o erro de taxa de variação da frequência. Por último, a fim de se reafirmar o sincronismo existente entre as medições realizadas por mais de um equipamento, estimou-se os fasores e a frequência em pontos distintos do sistema 4 Barras do IEEE, simulado em tempo real no RTDS, onde pode-se observar a estimação correta da defasagem entre duas barras desse sistema. / The present work proposes of a low cost Phasor Measurement Unity (PMU), for monitoring the power distribution system. The proposed meter can be connected at the low voltage level, making possible the monitoring of the distribution system and the transmission system. The algorithm used to compute the phasor estimation that composes the embedded software in the equipment uses the Savitzky-Golay filter to approximate the differentiation process, necessary in the frequency estimation of the fundamental component of the signal. The hardware of the equipment is composed by a microprocessor AMR TM4C1294NCPDT of Texas Instruments, a uBlox GPS NEO-6M module, a Wi-Fi ESP8266 module and an analog conditioning circuit. The synchronism of the measurements is guaranteed due to a pulse per second signal from the GPS module. For the transmission of the data generated by the PMU, the protocol suggested by the standard is used. The estimated parameters can be visualized in real time through the Synchrophasor Data Monitor Software. The results contemplate the tests required by the IEEE standard C37.118.1 and the analyses of the total vector error, frequency error and rate of change of frequency error. Finally, to attest the synchronism between different PMUs, a test in a Real Time Digital Simulator (RTDS) was made, where the 4 bus IEEE system was simulated. The difference of the angles estimated for different buses was computed and the obtained values were according to the expected.
10

WAMS-based Intelligent Load Shedding Scheme for Preventing Cascading Blackouts

Veda, Santosh Sambamoorthy 07 January 2013 (has links)
Severe disturbances in a large electrical interconnection cause a large mismatch in generation and load in the network, leading to frequency instability. If the mismatch is not rectified quickly, the system may disintegrate into multiple islands. Though the Automatic Generation Controls (AGC) perform well in correcting frequency deviation over a period of minutes, they are ineffective during a rolling blackout. While traditional Under Frequency Load Shedding Schemes (UFLS) perform quick control actions to arrest frequency decline in an islanded network, they are not designed to prevent unplanned islanding. The proposed Intelligent Load Shedding algorithm combines the effectiveness of AGC Scheme by observing tie line flows and the speed of operation of the UFLS Scheme by shedding loads intelligently, to preserve system integrity in the event of an evolving cascading failure. The proposed scheme detects and estimates the size of an event by monitoring the tie lines of a control area using Wide Area Measurement Systems (WAMS) and initiates load shedding by removing loads whose locations are optimally determined by a sensitivity analysis. The amount and location of the load shedding depends on the location and size of the initiating event, making the proposed algorithm adaptive and selective. Case Studies have been presented to show that control actions of the proposed scheme can directly mitigate a cascading blackout. / Ph. D.

Page generated in 0.0212 seconds