• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 2
  • 1
  • Tagged with
  • 24
  • 24
  • 8
  • 8
  • 7
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Εκτίμηση της τοξικότητας των τελικών εκροών από το σταθμό βιολογικής επεξεργασίας των αστικών αποβλήτων της Πάτρας με την χρήση βιοδεικτών (biotest)

Κονταλή, Ματίνα 03 April 2012 (has links)
Στην παρούσα μελέτη πραγματοποιήθηκε εκτίμηση της τοξικότητας των τελικών εκροών πριν και μετά το στάδιο της απολύμανσης (με τη χρήση της μεθόδους της χλωρίωσης) από το σταθμό βιολογικής επεξεργασίας των αστικών αποβλήτων της Πάτρας με την χρήση βιοδεικτών (biotest). Η μελέτη των τοξικών επιπτώσεων αυτών των εκροών και από τα δύο στάδια πραγματοποιήθηκε σε οργανισμούς-Βιοδείκτες τόσο των γλυκών όσο και αλμυρών υδάτων, όπως οι οργανισμοί Thamnocephalus platyurus και Artemia franciscana (με τη μορφή βιοτέστ Thamnotoxkit F και Artoxkit MTM αντίστοιχα), όσο και σε φυτικά είδη, όπως τα Sorghum saccharatum, Lepidum sativum και Sinapis alba (με τη μορφή Phytotoxkit). Επιπλέον έγινε ανίχνευση του μικροβιακού φορτίου πριν και μετά το στάδιο της χλωρίωσης, για την εκτίμηση της αποτελεσματικότητας της μεθόδου απολύμανσης των εκροών, καθώς και χημική ανάλυσή τους. Σύμφωνα με τα αποτελέσματα της παρούσας μελέτης, οι τελικές εκροές υγρών αποβλήτων που καταλήγουν στο στάδιο της απολύμανσης, με τη μέθοδο της χλωρίωσης παρουσιάζουν μεγάλες διακυμάνσεις τόσο στις φυσικοχημικές παραμέτρους και στη συγκέντρωση βαρέων μετάλλων που μετρήθηκαν, όσο και στην τοξικότητα που μπορεί να επιφέρουν στους οργανισμούς που χρησιμοποιήθηκαν. Τα αποτελέσματα της παρούσας μελέτης έδειξαν την αποτελεσματικότητα της μεθόδου όσο αφορά τη μείωση του μικροβιακού φορτίου των τελικών εκροών. Αντίθετα, η μελέτη τοξικότητας των τελικών εκροών με τη χρήση οργανισμών τόσο του γλυκού όσο και του αλμυρού νερού (Thamnocephalus platyurus και Artemia franciscana αντίστοιχα), καθώς και σε φυτικούς οργανισμούς (Sorgum saccharatum, Sinapsis alba και Lepidum sativum) έδειξε σημαντικές εποχικές μεταβολές στην επαγωγή τοξικών φαινομένων. Συγκεκριμένα, οι εκροές (μετά το στάδιο της χλωρίωσης effluents) φαίνεται να είναι λιγότερο τοξικές για τους οργανισμούς του αλμυρού νερού, συγκριτικά με τις τοξικές επιπτώσεις που προκαλούν οι εκροές πριν το στάδιο της χλωρίωσης (influents). Αντίθετα, οι εκροές που προκύπτουν μετά το στάδιο της χλωρίωσης παρουσιάζουν μεγαλύτερη τοξικότητα σε οργανισμούς του γλυκού νερού, σε σχέση με τις επιπτώσεις που προκαλούν οι εκροές πριν το στάδιο της χλωρίωσης, ενώ παρατηρήθηκε σημαντική αναστολή της αυξητικής ικανότητας των ειδών Sorgum saccharatum και Sinapsis alba σε κάθε περίπτωση. Συμπερασματικά, από τα αποτελέσματα της παρούσας μελέτης, φαίνεται η αποτελεσματικότητα της μεθόδου απολύμανσης των τελικών εκροών, όσο αφορά την απαλλαγή τους από μολυσματικούς παράγοντες, αλλά αναδεικνύονται τα προβλήματα τοξικότητας που μπορεί να επιφέρουν οι τελικές εκροές σε οργανισμούς των τελικών υδάτινων αποδεκτών (γλυκό και αλμυρό νερό), καθώς και η αναποτελεσματικότητα της χρήσης των τελικών εκροών σε δραστηριότητες όπως η άρδευση, λόγω της αναστολής που προκαλεί η χρήση τους σε φυτικούς οργανισμούς. / In this study was estimated the toxicity of the final effluents before and after the stage of disinfection (using the method of chlorination) in the wastewater treatment plant of Patras using bioindicators (biotest).The study of the toxic effects of these effluents and of the two stages was performed on organisms bioindicators both in freshwater and salt water, such as Thamnocephalus platyurus and Artemia franciscana (in the form of biotest Thamnotoxkit F and Artoxkit MTM respectively) and on plant species such as Sorghum saccharatum, Lepidum sativum and Sinapis alba (in the form of Phytotoxkit). Moreover the treated effluents were tested for microbiological parameters before and after the stage of chlorination, to assess the effectiveness of the method of disinfection of effluents, and also a chemical analysis was performed. According to the results of this study, the final effluents of wastewater that end in the process of disinfection, with the method of chlorination, vary widely both in physicochemical parameters and heavy metals that were measured, and as well the toxicity that can cause to organisms used. The results of this study showed the effectiveness of the method as regards reducing the microbial load of the final effluents. Instead, the study of final effluents toxicity using organisms of both fresh and saltwater (Thamnocephalus platyurus and Artemia franciscana, respectively) and in plant organisms (Sorgum saccharatum, Sinapsis alba and Lepidum sativum) showed significant seasonal changes in the induction of toxic reactions. Specifically, the effluents (after-chlorination effluents) seem to be less toxic for organisms of salt water, compared with the toxic effects caused by effluents before the stage of chlorination (influents). However, the effluents after the stage of chlorination are toxic in freshwater organisms compared to the effects caused by effluents before the stage of chlorination, while there was significant inhibition of growth capacity of species Sorgum saccharatum, Sinapsis alba in each case. In conclusion, the results of this study show the effectiveness of the method of disinfection of final effluents, as regards the discharge from contaminants, but highlighted the problems of toxicity that the final effluents can cause to organisms in the final water receiver (fresh and salty water), and the inefficiency of using of final effluents in activities such as irrigation, due to the inhibition caused by their use in plant organisms.
22

An Internship in Environmental Compliance and Water Management with Duke Energy Cincinnati, Ohio

Huddleston, Brian J. 21 April 2011 (has links)
No description available.
23

A water resources quality assessment case study involving a package plant in Mogale city

De Bruyn, Karin 11 1900 (has links)
Inadequately treated wastewater effluent is harmful to the receiving aquatic environment. Water-borne chemicals and microbial pathogens pose a health risk to anyone living downstream from sewage treatment facilities. This study assessed the effluent from a package plant with a design capacity of 48kℓ/24 hours, servicing 12 household units and a restaurant in Mogale City. Over a 12 month period, fortnightly water samples were collected from ten selected sites including two boreholes, a river and two dams. Standard parameters including physical (pH, EC, temperature, DO and SS), chemical (nutrient concentration) and biological (bacterial counts) were analysed using handheld meters, standard membrane filter techniques and colorimetric methods. One borehole was affected by pathogen and nitrate runoff from an adjacent poultry farm. If regularly monitored, the package plant effectively removed microbes (most samples contained 0 cfu/100mℓ) but above limit COD, ammonia and phosphate was released in the effluent (with maximum values of 322 mg/ℓ, 42.52 mg/ℓ and 7.18 mg/ℓ, respectively). Generally, river and dam water at the site was of good quality. / Environmental Science / M. Sc. (Environmental Science)
24

A water resources quality assessment case study involving a package plant in Mogale city

De Bruyn, Karin 11 1900 (has links)
Inadequately treated wastewater effluent is harmful to the receiving aquatic environment. Water-borne chemicals and microbial pathogens pose a health risk to anyone living downstream from sewage treatment facilities. This study assessed the effluent from a package plant with a design capacity of 48kℓ/24 hours, servicing 12 household units and a restaurant in Mogale City. Over a 12 month period, fortnightly water samples were collected from ten selected sites including two boreholes, a river and two dams. Standard parameters including physical (pH, EC, temperature, DO and SS), chemical (nutrient concentration) and biological (bacterial counts) were analysed using handheld meters, standard membrane filter techniques and colorimetric methods. One borehole was affected by pathogen and nitrate runoff from an adjacent poultry farm. If regularly monitored, the package plant effectively removed microbes (most samples contained 0 cfu/100mℓ) but above limit COD, ammonia and phosphate was released in the effluent (with maximum values of 322 mg/ℓ, 42.52 mg/ℓ and 7.18 mg/ℓ, respectively). Generally, river and dam water at the site was of good quality. / Environmental Science / M. Sc. (Environmental Science)

Page generated in 0.0913 seconds