  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Grundlegende Untersuchungen zum Laserstrahlbeschichten von Magnesiumlegierungen sowie zum artungleichen Laserstrahlschweißen mit Nd:YAG-Festkörperlaser und pulverförmigen Zusatzwerkstoffen

Kutschera, Ute. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2003--Clausthal.
32

Characterization and Optimization of High-order Harmonics after Adaptive Pulse Shaping / Charakterisierung und Optimierung von Hohen Harmonischen nach adaptiver Pulsformung

Lohbreier, Jan January 2008 (has links) (PDF)
Die Arbeit beschäftigt sich mit der Umwandlung von ultrakurzen Laserpulsen in weiche Röntgenpulse. Dabei geht es hauptsächlich um die adaptive Pulsformung des Laserpulses und dessen Einfluss auf die generierte harmonische Strahlung / This work deals with the conversion of ultrashort laser pulses into soft x-ray radiation. Mainly, the effect of adaptive pulse shaping on the generated high-order harmonic radiation is investigated
33

Aplicação de laser pulsado Nd:YAG na soldagem do aço super duplex UNS S32750 / Application of Nd: yag pulsed laser in steel welding super duplex UNS S32750

Franzini, Otacilio Donisete [UNESP] 13 December 2016 (has links)
Submitted by OTACILIO DONISETE FRANZINI null (otaciliodf@hotmail.com) on 2016-12-21T11:37:28Z No. of bitstreams: 1 APLICAÇÃO DE LASER PULSADO Nd YAG NA SOLDAGEM DO AÇO SUPER DUPLEX UNS S32750.pdf: 3133785 bytes, checksum: 7f73ce4a1615cca31edb63d392f368f2 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-12-22T12:59:13Z (GMT) No. of bitstreams: 1 franzini_od_me_ilha.pdf: 3133785 bytes, checksum: 7f73ce4a1615cca31edb63d392f368f2 (MD5) / Made available in DSpace on 2016-12-22T12:59:13Z (GMT). No. of bitstreams: 1 franzini_od_me_ilha.pdf: 3133785 bytes, checksum: 7f73ce4a1615cca31edb63d392f368f2 (MD5) Previous issue date: 2016-12-13 / Os aços inoxidáveis Duplex e Super Duplex, 50% austenita e 50% ferrita, combinam as características mais desejáveis dos aços ferríticos e austeníticos, possuem excelente resistência mecânica e à corrosão para uma ampla variedade de meios, com expressiva resistência à corrosão em água do mar e outros ambientes contendo cloreto, devido a seu elevado nível de cromo, molibdênio, e nitrogênio. Quando soldado a região do metal de solda desses aços perdem suas características de resistência mecânica e à corrosão devido ao desbalanceamento das fases ferrita e austenita. No presente trabalho foi analisado a influência do processo de soldagem autógena a laser Pulsado Nd:YAG nas características mecânicas e microestruturais da junta soldada, variando a taxa de sobreposição dos pulsos de 40 a 90% em chapas de aço inoxidável Super Duplex UNS S32750 com 1,5 mm de espessura. Utilizou-se uma fonte laser pulsada Nd.YAG, United Winner 150A, com potência máxima de 150 W. A energia do pulso de soldagem foi fixada em 10J, potência de pico de 2 kW, largura temporal de 5 ms e frequência variando entre 1,5 e 9,0 Hz. Como gás de proteção utilizou-se argônio puro com vazão de 10 l/min. A caracterização microestrutural foi realizada através de microscopia ótica e microscopia eletrônica de varredura. Os resultados mostraram que o aumento da taxa de sobreposição da junta de 40% até 90% aumenta a resistência mecânica e a dureza do metal de solda. Em relação à microestrutura do metal de solda observou-se uma ferritização da mesma com pequena fração volumétrica de austenita nas regiões de contorno de grão. Não foi observada a presença de fases frágeis no metal de solda. / Duplex Stainless steels and Super Duplex 50% austenite and 50% ferrite, combine the most desirable traits of ferritic and austenitic steels possess excellent mechanical strength and corrosion resistance to a wide variety of ways, with substantial corrosion resistance in seawater and other environments containing chloride, due to its high level of chromium, molybdenum, and nitrogen. When welded to the weld metal region of these steels lose their mechanical strength features and corrosion due to the imbalance of the ferrite and austenite phases. In this paper we analyzed the influence of the welding process autogenous laser Pulsed Nd: YAG laser on the mechanical and microstructural features of the welded joint, by varying the overlap rate of pulses from 40 to 90% in stainless steel plates Super Duplex UNS S32750 with 1.5 mm thick. We used a pulsed laser source Nd.YAG, United Winner 150A, with maximum power of 150 W. The power of the welding pulse was set at 10 J, peak power of 2 kW, temporal width of 5 ms and frequency ranging from 1.5 and 9.0 Hz. As shielding gas used is pure argon with a flow rate of 10 l / min. Microstructural characterization was performed by optical microscopy and scanning electron microscopy. The results showed that increasing the overlap rate of 40% to 90% joint strength increases and the hardness of the weld metal. Regarding the welding ferritização observed a metal microstructure thereof with small volume fraction of the austenite grain boundary regions. It was observed the presence of brittle phases in the weld metal.
34

Aplicação de laser pulsado Nd:YAG na soldagem do aço super duplex UNS S32750 /

Franzini, Otacilio Donisete January 2016 (has links)
Orientador: Vicente Afonso Ventrella / Resumo: Os aços inoxidáveis Duplex e Super Duplex, 50% austenita e 50% ferrita, combinam as características mais desejáveis dos aços ferríticos e austeníticos, possuem excelente resistência mecânica e à corrosão para uma ampla variedade de meios, com expressiva resistência à corrosão em água do mar e outros ambientes contendo cloreto, devido a seu elevado nível de cromo, molibdênio, e nitrogênio. Quando soldado a região do metal de solda desses aços perdem suas características de resistência mecânica e à corrosão devido ao desbalanceamento das fases ferrita e austenita. No presente trabalho foi analisado a influência do processo de soldagem autógena a laser Pulsado Nd:YAG nas características mecânicas e microestruturais da junta soldada, variando a taxa de sobreposição dos pulsos de 40 a 90% em chapas de aço inoxidável Super Duplex UNS S32750 com 1,5 mm de espessura. Utilizou-se uma fonte laser pulsada Nd.YAG, United Winner 150A, com potência máxima de 150 W. A energia do pulso de soldagem foi fixada em 10J, potência de pico de 2 kW, largura temporal de 5 ms e frequência variando entre 1,5 e 9,0 Hz. Como gás de proteção utilizou-se argônio puro com vazão de 10 l/min. A caracterização microestrutural foi realizada através de microscopia ótica e microscopia eletrônica de varredura. Os resultados mostraram que o aumento da taxa de sobreposição da junta de 40% até 90% aumenta a resistência mecânica e a dureza do metal de solda. Em relação à microestrutura do metal de solda observou-se u... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
35

Avaliação da eficácia de clareamento, permeabilidade e morfologia superficial do esmalte submetido a diferentes técnicas de aplicação do peróxido de hidrogênio a 35%, após aplicação de flúor / Evaluation of the effectiveness of whitening, morphlogy and perneability of enamel surface under different techniques for application of a hydrogen peroxide 35% after application of fluoride

Schiavoni, Renato Jonas dos Santos 31 March 2010 (has links)
Alterações visuais, histoquímicas e micromorfológicas podem ser observadas em superfícies dentais submetidas ao clareamento, desencadeando sensibilidade, menor resistência ao desgaste, maior manchamento e aderência bacteriana. Uma forma de verificar a ocorrência de danos superficiais e sub-superficiais é através da permeabilidade e da avaliação superficial por meio de microscopia eletrônica de varredura. Assim, este estudo in vitro teve por objetivo avaliar a eficácia de clareamento em dentes manchados, a permeabilidade e a morfologia superficial do esmalte dental após tratamento com diferentes técnicas de aplicação do peróxido de hidrogênio a 35% (FGM) seguido ou não da aplicação de flúor. Foram utilizados 260 incisivos bovinos, com superfícies de esmalte de 10x10 mm de área. Após, os espécimes foram casualmente distribuídos (n = 10) e submetidos ao manchamento com café, chá preto e vinho tinto por 72 horas. As medidas de cor eram realizadas com espectrofotômetro de reflexão nos tempos inicial, após o manchamento e logo após a fase de clareamento. Após o período de manchamento os fragmentos eram clareados com peróxido de hidrogênio a 35% (FGM) - convencional, ativado com LED ou laser de Er:YAG seguido ou não da aplicação de flúor (Desensibilize KF 2%, FGM). Os grupos controles eram expostos: a saliva artificial e a aplicação de flúor + saliva artificial. O tratamento clareador foi realizado de acordo com as recomendações do fabricante. No restante do período diário, os espécimes eram imersos em saliva artificial. A seguir, os fragmentos foram subdivididos em dois fragmentos de aproximadamente 5x5 mm de área, sendo um submetido à avaliação da permeabilidade e o outro a avaliação da superfície do esmalte através de microscopia eletrônica de varredura. O método de coloração histoquímica foi utilizado para evidenciar a extensão da permeabilidade no esmalte. Do esmalte eram obtidos três cortes avaliados em microscopia óptica, através de um software de digitalização de imagem (Axion Vision 3.1) verificando a penetração dos íons cobre em relação à espessura total do esmalte. As fotomicrografias eletrônicas de varredura das superfícies vestibulares do esmalte, com aumento de 2000X, foram digitalizadas e avaliadas. Para as análises estatísticas, foi considerado o valor de alteração de cor de cada fragmento nos diferentes tempos de observação e a média das três secções de um mesmo dente para a avaliação da permeabilidade. Em relação à MEV observou-se que em relação aos processos de clareamento, foi encontrado diferenças quando comparadas aos grupos controles. Os grupos controles apresentaram superfícies dentais lisas e regulares. Já os grupos tratados com PH35% e PH 35% + LED apresentaram superfícies dentais marcadas pela presença dos prismas de esmalte suavemente esboçados em meio a um esmalte interprísmático de textura lisa. A aplicação do Er:YAG promoveu a remoção da camada aprismática e exposição clara dos prismas de esmalte, depressões, tornando a superfície porosa e irregular. Nos grupos em que se aplicou o flúor, independente do tipo de clareamento realizado, observou-se superfícies relativamente cobertas por um precipitado fusiforme. Em relação à permeabilidade, os resultados demonstraram não haver diferença significativa. Já em relação à alteração de cor foi encontrada diferença estatística ente o agente aplicado ativado pelo Er:YAG, o método a alcançar as tonalidades de cor mais claras, quando comparado aos métodos convencional e ativado pelo LED. Concluímos que novos estudos são necessários para que se estabeleçam parâmetros adequados e seguros para a aplicação do laser. Isso fará com que se consiga não só melhor tonalidade de cor, mas menores efeitos deletérios na morfologia superficial do esmalte clareado. / Visual changes, micromorphological and histochemical can be observed in areas subjected to dental bleaching, triggering sensitivity, lower wear resistance, increased staining and bacterial adhesion. One way to check the damage to surface and subsurface is through the permeability and surface evaluation by scanning electron microscopy. Thus, this in vitro study was to evaluate the effectiveness of whitening stained teeth, permeability and morphology of enamel after treatment with different techniques of application of hydrogen peroxide 35% (FGM) whether or not the application of fluoride . We used 260 bovine incisors with enamel surfaces of 10x10 mm in size. After, the specimens were randomly distributed (n = 10) and subjected to staining with coffee, black tea and red wine for 72 hours. The color measurements were made at a reflection spectrophotometer in early times, after staining and after the bleaching stage. After the period of staining the fragments were bleached with hydrogen peroxide 35% (FGM) - conventional activated LED or laser Er:YAG whether or not the application of fluoride (KF Desensibilize 2%, FGM). Control groups were exposed: the artificial saliva and fluoride application + artificial saliva. The bleaching treatment was performed according to the manufacturer\'s recommendations. The rest of the daily period, the specimens were immersed in artificial saliva. Next, the fragments were divided into two fragments of approximately 5x5 mm in size, being submitted to an evaluation of the permeability and the other to evaluate the enamel surface by scanning electron microscopy. The histochemical staining method was used to show the extent of the permeability of enamel. Enamel were obtained from three sections evaluated with optical microscopy, using a software image scanning (Axion Vision 3.1) verifying the penetration of copper ions in relation to the total thickness of enamel. The images of scanning electron photomicrographs of the vestibular enamel, an increase of 2000X were scanned and evaluated. For statistical analysis, we considered the color change of each fragment in different observation times and the average of three sections of the same tooth for assessing permeability. Regarding the SEM showed that in relation to the bleaching procedure, we found differences when compared to control groups. The control groups showed tooth surfaces smooth and regular. Since the groups treated with PH35% and 35% PH + LED tooth surfaces showed marked by the presence of enamel rods gently outlined in the midst of an enamel interprismatic smooth texture. The application of Er:YAG promoted the removal of the layer aprismatic and clear statement of the enamel prisms, depressions, making the surface porous and irregular. In groups that applied fluoride, regardless of the type of bleaching done, it was observed on surfaces covered by a precipitate fusiform. In relation to permeability, the results showed no significant difference. In relation to the color change was statistical difference between individual agents used and the Er:YAG method to achieve the color shades lighter when compared to PH35 and PH35% + LED. We conclude that further studies are needed to find themselves safe and appropriate parameters for the laser application. This will make you not only get better color tone, but less deleterious effects on enamel surface morphology cleared.
36

Microtração de sistemas adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após preparo cavitário com laser de Er: YAG: avaliação in vitro / Microtensile bond strength of selfetch adhesive systems in demineralised dentin of primary teeth after Er: YAG laser irradiation: in vitro evaluation

Almeida, Cintia Guimaraes de 01 June 2011 (has links)
O objetivo deste estudo foi avaliar a resistência à microtração de adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após a irradiação com laser de Er: YAG. Oitenta e dois molares decíduos tiveram a porção oclusal seccionada transversalmente e os espécimes foram desgastados com lixas de carbeto de silício de granulações 360 e 600 até expor a dentina. Os 60 espécimes utilizados no teste de microtração foram preenchidos com resina composta fotopolimerizável na região correspondente à câmara pulpar, isolados com esmalte cosmético mantendo a superfície dentinária exposta e, em seguida imersos em solução desmineralizante por seis dias em estufa a 37° C para indução de lesão de cárie artificial em dentina. Após a desmineralização, os espécimes foram preparados com laser de Er: YAG (n=30) com os parâmetros de 260 mJ, 3 Hz, 47 J/cm2, 0,81W e com broca de aço esférica em baixa rotação (n=30). Sobre as superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes Clearfil SE Bond (Kuraray); Adper™ Easy One (3M ESPE) e Adper™ SE Plus (3M ESPE) e, em seguida foram confeccionados platôs de resina composta Z 250. Após termociclagem (500 ciclos), os corpos de prova foram seccionados produzindo palitos de aproximadamente 1 mm2 de área transversal, que foram submetidos ao teste de microtração e os valores obtidos foram analisados estatisticamente através de ANOVA e teste de Duncan (5%). A análise qualitativa dos tipos de fraturas foi realizada por meio de lupa estereoscópica (aumento de 40X) e da interface adesiva por meio de MEV. Para a análise química da dentina através de espectroscopia no infravermelho por transformada de Fourier (FTIR), foram utilizados discos de dentina após o preparo superficial com a broca (n=5) e com o laser (n=5), e comparadas com as análises de tecido dentinário sadio e desmineralizado obtidas dos mesmos espécimes. Os resultados foram submetidos ao teste estatístico t−Student (5%). O teste de microtração demonstrou que houve diferença significativa entre os adesivos, sendo que o grupo controle (Clearfil e broca) obteve o melhor desempenho comparativamente a todos os grupos avaliados. O preparo com laser de Er: YAG afetou adversamente a adesão para os sistemas adesivos Clearfil SE Bond e Adper™ Easy One em comparação com os grupos preparados com broca. Nos grupos irradiados com laser, o sistema adesivo Clearfil SE Bond foi o que proporcionou o maior valor médio de microtração. Os resultados da FTIR demonstraram que, com a irradiação da dentina desmineralizada, houve um decréscimo na quantidade de matéria orgânica e de carbonato em relação ao grupo da dentina sadia. No substrato preparado com broca, observouse aumento da matéria orgânica e redução de carbonato. Concluise que, em relação aos sistemas adesivos, o Clearfil SE Bond teve o melhor desempenho no teste de resistência à microtração em dentina de dentes decíduos. A irradiação com laser de Er: YAG afetou adversamente a adesão dos sistemas adesivos Clearfil SE Bond e Adper™ Easy One. A irradiação com laser de Er:YAG decresceu de maneira significativa a quantidade de matéria orgânica presente na dentina de dentes decíduos. / The purpose of this study was to evaluate the microtensile bond strength of three selfetch adhesives systems to demineralized dentin of primary teeth after irradiation with Er: YAG laser. Eighty two primary molars had the occlusal enamel sectioned and the specimens were grounded with silicon carbide sandpaper grits of 360 and 600 to expose the dentin. The 60 specimens used in the microtensile test were filled with composite resin in the region corresponding to the pulp chamber, insulated with nail varnish keeping the exposed dentin surface and then immersed in demineralizing solution for six days in a stove at 37 Celsius degrees in order to produce artificial carieslike lesions in dentin. After demineralization, the specimens were prepared with Er: YAG (n = 30) using as parameters 260 mJ, 3 Hz, 47 J/cm2, 0.81 W and a round steel drill at low speed (n = 30 ). On the prepared surfaces were applied three self−etch adhesives systems Clearfil SE Bond (Kuraray); Adper™ Easy One (3M ESPE) and AdperTM SE Plus (3M ESPE) and then plateaus of composite resin Z 250 were built up. After thermocycling (500 cycles), specimens were sectioned to produce multiple sticks of approximately 1 mm2 crosssectional area, which were subjected to microtensile test and the data were analyzed with ANOVA and Duncan test at a significance level of 0.05. The qualitative analysis of the types of fractures was performed using a stereomicroscope (X40 magnification) and the morphological analyses of adhesive interfaces were performed by scanning electron microscopy (SEM). Chemical analysis of the dentin by Fourier transform infrared spectroscopy (FTIR) were performed in dentin discs after surface preparation with the steel drill (n = 5) and laser (n = 5) and compared with the values previously obtained from the analysis of sound and demineralized dentin tissue in the same specimens. The results were analyzed by Student\'s t−test at a significance level of 0.05. Regarding the microtensile bond strength there was a significant difference between the adhesive systems, and the control group (Clearfil and steel drill) had the best performance compared to all groups. Er: YAG laser irradiation adversely affected bond strength to the Clearfil SE Bond and Adper™ Easy One compared with the groups prepared with steel drill. In the laser groups Clearfil SE Bond reached the highest average bond strength. Results of FTIR analysis showed that the hydration of dentin remained normal after both preparations. With laser irradiation of demineralized dentin there was a decrease in the amount of organic matter and carbonate in relation to the group of sound dentin. The analyses of substrate prepared with steel drill showed an increase in organic matter and reduction of carbonate. The conclusion in relation to adhesive systems was that Clearfil SE Bond had the best performance in microtensile bond strength in primary teeth dentin. Laser irradiation adversely affected the bond strength of Clearfil SE Bond and Adper™ Easy One selfetch adhesive systems. Laser irradiation had significantly reduced the organic matter content in dentin of deciduous teeth.
37

Avaliação da eficácia de clareamento, permeabilidade e morfologia superficial do esmalte submetido a diferentes técnicas de aplicação do peróxido de hidrogênio a 35%, após aplicação de flúor / Evaluation of the effectiveness of whitening, morphlogy and perneability of enamel surface under different techniques for application of a hydrogen peroxide 35% after application of fluoride

Renato Jonas dos Santos Schiavoni 31 March 2010 (has links)
Alterações visuais, histoquímicas e micromorfológicas podem ser observadas em superfícies dentais submetidas ao clareamento, desencadeando sensibilidade, menor resistência ao desgaste, maior manchamento e aderência bacteriana. Uma forma de verificar a ocorrência de danos superficiais e sub-superficiais é através da permeabilidade e da avaliação superficial por meio de microscopia eletrônica de varredura. Assim, este estudo in vitro teve por objetivo avaliar a eficácia de clareamento em dentes manchados, a permeabilidade e a morfologia superficial do esmalte dental após tratamento com diferentes técnicas de aplicação do peróxido de hidrogênio a 35% (FGM) seguido ou não da aplicação de flúor. Foram utilizados 260 incisivos bovinos, com superfícies de esmalte de 10x10 mm de área. Após, os espécimes foram casualmente distribuídos (n = 10) e submetidos ao manchamento com café, chá preto e vinho tinto por 72 horas. As medidas de cor eram realizadas com espectrofotômetro de reflexão nos tempos inicial, após o manchamento e logo após a fase de clareamento. Após o período de manchamento os fragmentos eram clareados com peróxido de hidrogênio a 35% (FGM) - convencional, ativado com LED ou laser de Er:YAG seguido ou não da aplicação de flúor (Desensibilize KF 2%, FGM). Os grupos controles eram expostos: a saliva artificial e a aplicação de flúor + saliva artificial. O tratamento clareador foi realizado de acordo com as recomendações do fabricante. No restante do período diário, os espécimes eram imersos em saliva artificial. A seguir, os fragmentos foram subdivididos em dois fragmentos de aproximadamente 5x5 mm de área, sendo um submetido à avaliação da permeabilidade e o outro a avaliação da superfície do esmalte através de microscopia eletrônica de varredura. O método de coloração histoquímica foi utilizado para evidenciar a extensão da permeabilidade no esmalte. Do esmalte eram obtidos três cortes avaliados em microscopia óptica, através de um software de digitalização de imagem (Axion Vision 3.1) verificando a penetração dos íons cobre em relação à espessura total do esmalte. As fotomicrografias eletrônicas de varredura das superfícies vestibulares do esmalte, com aumento de 2000X, foram digitalizadas e avaliadas. Para as análises estatísticas, foi considerado o valor de alteração de cor de cada fragmento nos diferentes tempos de observação e a média das três secções de um mesmo dente para a avaliação da permeabilidade. Em relação à MEV observou-se que em relação aos processos de clareamento, foi encontrado diferenças quando comparadas aos grupos controles. Os grupos controles apresentaram superfícies dentais lisas e regulares. Já os grupos tratados com PH35% e PH 35% + LED apresentaram superfícies dentais marcadas pela presença dos prismas de esmalte suavemente esboçados em meio a um esmalte interprísmático de textura lisa. A aplicação do Er:YAG promoveu a remoção da camada aprismática e exposição clara dos prismas de esmalte, depressões, tornando a superfície porosa e irregular. Nos grupos em que se aplicou o flúor, independente do tipo de clareamento realizado, observou-se superfícies relativamente cobertas por um precipitado fusiforme. Em relação à permeabilidade, os resultados demonstraram não haver diferença significativa. Já em relação à alteração de cor foi encontrada diferença estatística ente o agente aplicado ativado pelo Er:YAG, o método a alcançar as tonalidades de cor mais claras, quando comparado aos métodos convencional e ativado pelo LED. Concluímos que novos estudos são necessários para que se estabeleçam parâmetros adequados e seguros para a aplicação do laser. Isso fará com que se consiga não só melhor tonalidade de cor, mas menores efeitos deletérios na morfologia superficial do esmalte clareado. / Visual changes, micromorphological and histochemical can be observed in areas subjected to dental bleaching, triggering sensitivity, lower wear resistance, increased staining and bacterial adhesion. One way to check the damage to surface and subsurface is through the permeability and surface evaluation by scanning electron microscopy. Thus, this in vitro study was to evaluate the effectiveness of whitening stained teeth, permeability and morphology of enamel after treatment with different techniques of application of hydrogen peroxide 35% (FGM) whether or not the application of fluoride . We used 260 bovine incisors with enamel surfaces of 10x10 mm in size. After, the specimens were randomly distributed (n = 10) and subjected to staining with coffee, black tea and red wine for 72 hours. The color measurements were made at a reflection spectrophotometer in early times, after staining and after the bleaching stage. After the period of staining the fragments were bleached with hydrogen peroxide 35% (FGM) - conventional activated LED or laser Er:YAG whether or not the application of fluoride (KF Desensibilize 2%, FGM). Control groups were exposed: the artificial saliva and fluoride application + artificial saliva. The bleaching treatment was performed according to the manufacturer\'s recommendations. The rest of the daily period, the specimens were immersed in artificial saliva. Next, the fragments were divided into two fragments of approximately 5x5 mm in size, being submitted to an evaluation of the permeability and the other to evaluate the enamel surface by scanning electron microscopy. The histochemical staining method was used to show the extent of the permeability of enamel. Enamel were obtained from three sections evaluated with optical microscopy, using a software image scanning (Axion Vision 3.1) verifying the penetration of copper ions in relation to the total thickness of enamel. The images of scanning electron photomicrographs of the vestibular enamel, an increase of 2000X were scanned and evaluated. For statistical analysis, we considered the color change of each fragment in different observation times and the average of three sections of the same tooth for assessing permeability. Regarding the SEM showed that in relation to the bleaching procedure, we found differences when compared to control groups. The control groups showed tooth surfaces smooth and regular. Since the groups treated with PH35% and 35% PH + LED tooth surfaces showed marked by the presence of enamel rods gently outlined in the midst of an enamel interprismatic smooth texture. The application of Er:YAG promoted the removal of the layer aprismatic and clear statement of the enamel prisms, depressions, making the surface porous and irregular. In groups that applied fluoride, regardless of the type of bleaching done, it was observed on surfaces covered by a precipitate fusiform. In relation to permeability, the results showed no significant difference. In relation to the color change was statistical difference between individual agents used and the Er:YAG method to achieve the color shades lighter when compared to PH35 and PH35% + LED. We conclude that further studies are needed to find themselves safe and appropriate parameters for the laser application. This will make you not only get better color tone, but less deleterious effects on enamel surface morphology cleared.
38

Microtração de sistemas adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após preparo cavitário com laser de Er: YAG: avaliação in vitro / Microtensile bond strength of selfetch adhesive systems in demineralised dentin of primary teeth after Er: YAG laser irradiation: in vitro evaluation

Cintia Guimaraes de Almeida 01 June 2011 (has links)
O objetivo deste estudo foi avaliar a resistência à microtração de adesivos autocondicionantes em dentina desmineralizada de dentes decíduos após a irradiação com laser de Er: YAG. Oitenta e dois molares decíduos tiveram a porção oclusal seccionada transversalmente e os espécimes foram desgastados com lixas de carbeto de silício de granulações 360 e 600 até expor a dentina. Os 60 espécimes utilizados no teste de microtração foram preenchidos com resina composta fotopolimerizável na região correspondente à câmara pulpar, isolados com esmalte cosmético mantendo a superfície dentinária exposta e, em seguida imersos em solução desmineralizante por seis dias em estufa a 37° C para indução de lesão de cárie artificial em dentina. Após a desmineralização, os espécimes foram preparados com laser de Er: YAG (n=30) com os parâmetros de 260 mJ, 3 Hz, 47 J/cm2, 0,81W e com broca de aço esférica em baixa rotação (n=30). Sobre as superfícies preparadas foram aplicados três sistemas adesivos autocondicionantes Clearfil SE Bond (Kuraray); Adper™ Easy One (3M ESPE) e Adper™ SE Plus (3M ESPE) e, em seguida foram confeccionados platôs de resina composta Z 250. Após termociclagem (500 ciclos), os corpos de prova foram seccionados produzindo palitos de aproximadamente 1 mm2 de área transversal, que foram submetidos ao teste de microtração e os valores obtidos foram analisados estatisticamente através de ANOVA e teste de Duncan (5%). A análise qualitativa dos tipos de fraturas foi realizada por meio de lupa estereoscópica (aumento de 40X) e da interface adesiva por meio de MEV. Para a análise química da dentina através de espectroscopia no infravermelho por transformada de Fourier (FTIR), foram utilizados discos de dentina após o preparo superficial com a broca (n=5) e com o laser (n=5), e comparadas com as análises de tecido dentinário sadio e desmineralizado obtidas dos mesmos espécimes. Os resultados foram submetidos ao teste estatístico t−Student (5%). O teste de microtração demonstrou que houve diferença significativa entre os adesivos, sendo que o grupo controle (Clearfil e broca) obteve o melhor desempenho comparativamente a todos os grupos avaliados. O preparo com laser de Er: YAG afetou adversamente a adesão para os sistemas adesivos Clearfil SE Bond e Adper™ Easy One em comparação com os grupos preparados com broca. Nos grupos irradiados com laser, o sistema adesivo Clearfil SE Bond foi o que proporcionou o maior valor médio de microtração. Os resultados da FTIR demonstraram que, com a irradiação da dentina desmineralizada, houve um decréscimo na quantidade de matéria orgânica e de carbonato em relação ao grupo da dentina sadia. No substrato preparado com broca, observouse aumento da matéria orgânica e redução de carbonato. Concluise que, em relação aos sistemas adesivos, o Clearfil SE Bond teve o melhor desempenho no teste de resistência à microtração em dentina de dentes decíduos. A irradiação com laser de Er: YAG afetou adversamente a adesão dos sistemas adesivos Clearfil SE Bond e Adper™ Easy One. A irradiação com laser de Er:YAG decresceu de maneira significativa a quantidade de matéria orgânica presente na dentina de dentes decíduos. / The purpose of this study was to evaluate the microtensile bond strength of three selfetch adhesives systems to demineralized dentin of primary teeth after irradiation with Er: YAG laser. Eighty two primary molars had the occlusal enamel sectioned and the specimens were grounded with silicon carbide sandpaper grits of 360 and 600 to expose the dentin. The 60 specimens used in the microtensile test were filled with composite resin in the region corresponding to the pulp chamber, insulated with nail varnish keeping the exposed dentin surface and then immersed in demineralizing solution for six days in a stove at 37 Celsius degrees in order to produce artificial carieslike lesions in dentin. After demineralization, the specimens were prepared with Er: YAG (n = 30) using as parameters 260 mJ, 3 Hz, 47 J/cm2, 0.81 W and a round steel drill at low speed (n = 30 ). On the prepared surfaces were applied three self−etch adhesives systems Clearfil SE Bond (Kuraray); Adper™ Easy One (3M ESPE) and AdperTM SE Plus (3M ESPE) and then plateaus of composite resin Z 250 were built up. After thermocycling (500 cycles), specimens were sectioned to produce multiple sticks of approximately 1 mm2 crosssectional area, which were subjected to microtensile test and the data were analyzed with ANOVA and Duncan test at a significance level of 0.05. The qualitative analysis of the types of fractures was performed using a stereomicroscope (X40 magnification) and the morphological analyses of adhesive interfaces were performed by scanning electron microscopy (SEM). Chemical analysis of the dentin by Fourier transform infrared spectroscopy (FTIR) were performed in dentin discs after surface preparation with the steel drill (n = 5) and laser (n = 5) and compared with the values previously obtained from the analysis of sound and demineralized dentin tissue in the same specimens. The results were analyzed by Student\'s t−test at a significance level of 0.05. Regarding the microtensile bond strength there was a significant difference between the adhesive systems, and the control group (Clearfil and steel drill) had the best performance compared to all groups. Er: YAG laser irradiation adversely affected bond strength to the Clearfil SE Bond and Adper™ Easy One compared with the groups prepared with steel drill. In the laser groups Clearfil SE Bond reached the highest average bond strength. Results of FTIR analysis showed that the hydration of dentin remained normal after both preparations. With laser irradiation of demineralized dentin there was a decrease in the amount of organic matter and carbonate in relation to the group of sound dentin. The analyses of substrate prepared with steel drill showed an increase in organic matter and reduction of carbonate. The conclusion in relation to adhesive systems was that Clearfil SE Bond had the best performance in microtensile bond strength in primary teeth dentin. Laser irradiation adversely affected the bond strength of Clearfil SE Bond and Adper™ Easy One selfetch adhesive systems. Laser irradiation had significantly reduced the organic matter content in dentin of deciduous teeth.
39

Diagnostik an laserinduzierten Plasmakanälen und Mikropinchstrukturen mittels Kurzzeitinterferometrie und zeitaufgelöster Röntgenspektroskopie

Blaudeck, Thomas 17 December 2002 (has links)
This work deals with the interaction of intense 100 ps laser pulses with double-layer foil targets, consisting of one dielectric (Mylar) layer and one metallic layer. The diagnostics of the evolving plasmas is done by the means of shorttime interferometry, time-resolved X-ray spectroscopy, and methods of ion dosimetry in polymer nuclear track detectors (CR-39). / Die Arbeit beschäftigt sich mit der Wechselwirkung intensiver 100-ps-Laserpulse eines Nd:YAG-Lasersystems mit Zweischicht-Folientargets, die aus einer dielektrischen Schicht (Mylar) und einer metallischen Schicht bestehen. Die entstehenden Plasmen werden mittels Kurzzeitinterferometrie und zeitaufgelöster Röntgenspektroskopie sowie mit Methoden der Ionendosimetrie in Polymer-Kernspurätzdetektoren (CR-39) untersucht.
40

Improvement of a fluorescence immunoassay with a compact diode-pumped solid state laser at 315 nm

Niederkrüger, Matthias, Salb, Christian, Beck, Michael, Hildebrandt, Niko, Löhmannsröben, Hans-Gerd, Marowsky, Gerd January 2006 (has links)
We demonstrate the improvement of fluorescence immunoassay (FIA) diagnostics in deploying a newly developed compact diode-pumped solid state (DPSS) laser with emission at 315 nm. The laser is based on the quasi-three-level transition in Nd:YAG at 946 nm. The pulsed operation is either realized by an active Q-switch using an electro-optical device or by introduction of a Cr<SUP>4+</SUP>:YAG saturable absorber as passive Q-switch element. By extra-cavity second harmonic generation in different nonlinear crystal media we obtained blue light at 473 nm. Subsequent mixing of the fundamental and the second harmonic in a β-barium-borate crystal provided pulsed emission at 315 nm with up to 20 μJ maximum pulse energy and 17 ns pulse duration. Substitution of a nitrogen laser in a FIA diagnostics system by the DPSS laser succeeded in considerable improvement of the detection limit. Despite significantly lower pulse energies (7 μJ DPSS laser versus 150 μJ nitrogen laser), in preliminary investigations the limit of detection was reduced by a factor of three for a typical FIA.

Page generated in 0.038 seconds