Spelling suggestions: "subject:"zinc telluride"" "subject:"inc telluride""
11 |
Broadband IR stokes polarimetry for the electro-optic characterization of cadmium zinc tellurideFitzGerald, William 21 December 2017 (has links)
The infrared portion of the electro-magnetic spectrum is a challenging region in which
to perform optical techniques, limited by both device efficiency and availability. In
this dissertation, a new optical technique is introduced to facilitate polarization state
measurement across the mid-IR. In addition, cadmium zinc telluride (CZT) is investigated
as a potential new material suitable for electro-optic devices which function in the mid-IR,
while also being characterized by other optical analysis methods.
Thin film interference is discussed as it relates to optical techniques and electronic
devices. A Stokes polarimeter is used to study the oxide development on the surface of
CZT electronic devices, and the effect of natural thin films on substrates used in optical
techniques is discussed. In particular, the impact of thin film interference on sum-frequency generation spectroscopy measurements of methyl group orientation are assessed.
An FTIR source operated in step-scan mode is used to create a broadband, IR Stokes
polarimeter which measures the polarization state of light from 2.5-11 μm simultaneously.
Its design, involving two photo-elastic modulators and an analyzer, and theory are described in detail. This instrument is demonstrated by measuring linearly polarized light, and is applied to the measurement of the refractive index dispersion of quartz from 2.5-4 μm, which goes beyond the limits of literature values.
Electro-optic crystals of CZT with electrodes of gold and indium are characterized
at each wavelength in the mid-IR in terms of their electro-optic effects and apparent
depolarization using the Stokes polarimeter. The material displays high-resistivity,
allowing it to be operated with up to 5 kV applied DC voltage. The linear electro-optic
effect is observed, but overall properties of the samples are found to be heavily dependent
on the choice of metal for the electrodes. With a high-work function electrode material
in gold, a large depletion region is created when high voltage is applied, which leads to a
gradient in electric field throughout the material. This causes a beam of light transmitted through it to experience a distribution of electro-optic behaviours, which leads to overall
depolarization of the light. Indium’s work function is lower than gold’s, and is closer to
that of CZT. With indium electrodes, the electric field is found to be more consistent, and
behaviour is much closer to ideal.
The electro-optic effect of CZT is also characterized with AC applied voltage in order
to assess its suitability to AC applied voltage applications. The power supply used for
this was limited to 60 Hz, which precludes a complete characterization in this regard, but
unexpected behaviour was seen. A methodology utilizing an oscilloscope and FTIR was
developed in order to more completely understand the material response, and divergent
behaviour with positive and negative voltage was found. / Graduate / 2018-12-18
|
12 |
Τοmοscintigraphie myοcardique dοuble-isοtοpe (¹²³Ι/99mΤc) sur gamma-caméra à semi-cοnducteur : aspects méthodologiques et applications cliniques / Dual-isotope (123I/99mTc) myocardial SPECT using semiconductor gamma-cameras : methodological aspects and clinical applicationsBlaire, Tanguy 26 September 2017 (has links)
Les nouvelles gamma-caméras à semi-conducteurs utilisant des détecteurs au CZT sont dédiées aux explorations cardiaques. Leurs sensibilité, résolution spatiale et en énergie nettement améliorées comparativement aux gamma-caméras conventionnelles sont une révolution en médecine nucléaire. Ces gamma-caméras utilisent de nouvelles géométries d’acquisition, de nouveaux algorithmes de reconstruction, et ouvrent de nouvelles perspectives dans les études simultanées en double-isotope de l’123I et du 99mTc, dont les pics énergétiques sont proches.Nous avons étudié l’impact de l’amélioration de la résolution en énergie en comparant deux modèles de gamma-caméras à détecteurs semi-conducteurs aux gamma-caméras conventionnelles. A l’aide d’études sur fantômes anthropomorphes et chez des patients porteurs d’insuffisance cardiaque, notre travail s’est concentré sur les acquisitions scintigraphiques (i) de la fonction ventriculaire gauche (99mTc) en présence d’123I, (ii) de la perfusion myocardique (99mTc) en présence d’123I (innervation), et (iii) du rapport cardiomédiastinal de la fixation d’123I- métaiodobenzylguanidine (123I-MIBG) lors d’acquisitions double-isotope (123I-MIBG/99mTc- tétrofosmine) chez les patients souffrant d’insuffisance cardiaque.Nos résultats montrent que la meilleure résolution en énergie des gamma-caméras CZT permet en étude double-isotope (i) une évaluation de la FEVG et du mouvement régional dans les différentes fenêtres d'énergie (123I ou 99mTc) et les types d'acquisition (simple- vs double-isotope), (ii) une évaluation simultanée et combinée de la perfusion (99mTc) et de l’innervation (123I) du myocarde, et (iii) l’évaluation du rapport cardiomédiastinal de la fixation d’123I-MIBG. Chacune de ces trois parties a fait l’objet d’une publication. / New dedicated-cardiac cameras using CZT detectors have dramatically transformed the routine of myocardial perfusion imaging. With a better count detection sensitivity, an improved spatial and energy resolution, they potentially enable combined assessment of myocardial innervation (123I) and perfusion (99mTc) within a single imaging session. These cameras images with different sharpness and contrast-to-noise ratios.Using two CZT cameras with anthropomorphic phantom, and clinical studies in heart failure patients, our work focused on (i) the left ventricular function assessment within the 99mTc window in presence of 123I, (ii) the evaluation of regional myocardial innervation (123I) and perfusion (99mTc) match and mismatch with single- (separate 123I and 99mTc acquisition) and simultaneous dual-isotope acquisitions, and (iii) the late heart-to-mediastinal ratio (HMR) of 123I-MIBG uptake determined using dual-isotope CZT acquisition with that determined using conventional planar imaging in patients with heart failure.Our results found no impact of the acquisition mode (single vs dual) or the type of CZT camera on 123I and 99mTc defect size and mismatch, LVEF, and HMR of 123I-MIBG uptake.This work provides a new step toward simultaneous dual-isotope acquisition for combined innervation, perfusion and ventricular function assessment.
|
13 |
Instrumentation of CdZnTe detectors for measuring prompt gamma-rays emitted during particle therapy / Instrumentierung von CdZnTe Detektoren zur Messung prompter Gammastrahlung während der TeilchentherapieFödisch, Philipp 15 May 2017 (has links) (PDF)
Background: The irradiation of cancer patients with charged particles, mainly protons and carbon ions, has become an established method for the treatment of specific types of tumors. In comparison with the use of X-rays or gamma-rays, particle therapy has the advantage that the dose distribution in the patient can be precisely controlled. Tissue or organs lying near the tumor will be spared. A verification of the treatment plan with the actual dose deposition by means of a measurement can be done through range assessment of the particle beam. For
this purpose, prompt gamma-rays are detected, which are emitted by the affected target volume during irradiation.
Motivation: The detection of prompt gamma-rays is a task related to radiation detection and measurement. Nuclear applications in medicine can be found in particular for in vivo diagnosis. In that respect the spatially resolved measurement of gamma-rays is an essential technique for nuclear imaging, however, technical requirements of radiation measurement during particle therapy are much more challenging than those of classical applications. For this purpose, appropriate instruments beyond the state-of-the-art need to be developed and tested for detecting prompt gamma-rays. Hence the success of a method for range assessment of particle beams is largely determined by the implementation of electronics. In practice, this means that a suitable detector material with adapted readout electronics, signal and information processing, and data interface must be utilized to solve the challenges. Thus, the parameters of the system (e.g. segmentation, time or energy resolution) can be optimized depending on the method (e.g. slit camera, time-of-flight measurement or Compton camera). Regardless of the method, the detector system must have a high count rate capability and a large measuring range (>7 MeV). For a subsequent evaluation of a suitable method for imaging, the mentioned parameters may not be restricted by the electronics. Digital signal processing is predestined for multipurpose tasks, and, in terms of the demands made, the performance of such an implementation has to be determined.
Materials and methods: In this study, the instrumentation of a detector system for prompt gamma-rays emitted during particle therapy is limited to the use of a cadmium zinc telluride (CdZnTe, CZT) semiconductor detector. The detector crystal is divided into an 8x8 pixel array by segmented electrodes. Analog and digital signal processing are exemplarily tested with this type of detector and aims for application of a Compton camera to range assessment. The electronics are implemented with commercial off-the-shelf (COTS) components. If applicable, functional units of the detector system were digitalized and implemented in a field-programmable gate array (FPGA). An efficient implementation of the algorithms in terms of timing and logic utilization is fundamental to the design of digital circuits. The measurement system is characterized with radioactive sources to determine the measurement dynamic range and resolution. Finally, the performance is examined in terms of the requirements of particle therapy with experiments at particle accelerators.
Results: A detector system based on a CZT pixel detector has been developed and tested. Although the use of an application-specific integrated circuit is convenient, this approach was rejected because there was no circuit available which met the requirements. Instead, a multichannel, compact, and low-noise analog amplifier circuit with COTS components has been implemented. Finally, the 65 information channels of a detector are digitized, processed and visualized.
An advanced digital signal processing transforms the traditional approaches of nuclear electronics in algorithms and digital filter structures for an FPGA. With regard to the characteristic signals (e.g. varying rise times, depth-dependent energy measurement) of a CZT pixel detector, it could be shown that digital pulse processing results in a very good energy resolution (~2% FWHM at 511 keV), as well as permits a time measurement in the range of some tens of nanoseconds. Furthermore, the experimental results have shown that the dynamic range of the detector system could be significantly improved compared to the existing prototype of the Compton camera (~10 keV..7 MeV). Even count rates of ~100 kcps in a high-energy beam could be ultimately processed with the CZT pixel detector. But this is merely a limit of the detector due to its volume, and not related to electronics. In addition, the versatility of digital signal processing has been demonstrated with other detector materials (e.g. CeBr3). With foresight on high data throughput in a distributed data acquisition from multiple detectors, a Gigabit Ethernet link has been implemented as data interface.
Conclusions: To fully exploit the capabilities of a CZT pixel detector, a digital signal processing is absolutely necessary. A decisive advantage of the digital approach is the ease of use in a multichannel system. Thus with digitalization, a necessary step has been done to master the complexity of a Compton camera. Furthermore, the benchmark of technology shows that a CZT pixel detector withstands the requirements of measuring prompt gamma-rays during particle therapy. The previously used orthogonal strip detector must be replaced by the pixel detector in favor of increased efficiency and improved energy resolution. With the integration of the developed digital detector system into a Compton camera, it must be ultimately proven whether this method is applicable for range assessment in particle therapy. Even if another method is more convenient in a clinical environment due to practical considerations, the detector system of that method may benefit from the shown instrumentation of a digital signal processing system for nuclear applications. / Hintergrund: Die Bestrahlung von Krebspatienten mit geladenen Teilchen, vor allem Protonen oder Kohlenstoffionen, ist mittlerweile eine etablierte Methode zur Behandlung von speziellen Tumorarten. Im Vergleich mit der Anwendung von Röntgen- oder Gammastrahlen hat die Teilchentherapie den Vorteil, dass die Dosisverteilung im Patienten präziser gesteuert werden kann. Dadurch werden um den Tumor liegendes Gewebe oder Organe geschont. Die messtechnische Verifikation des Bestrahlungsplans mit der tatsächlichen Dosisdeposition kann über eine Reichweitenkontrolle des Teilchenstrahls erfolgen. Für diesen Zweck werden prompte Gammastrahlen detektiert, die während der Bestrahlung vom getroffenen Zielvolumen emittiert werden.
Fragestellung: Die Detektion von prompten Gammastrahlen ist eine Aufgabenstellung der Strahlenmesstechnik. Strahlenanwendungen in der Medizintechnik finden sich insbesondere in der in-vivo Diagnostik. Dabei ist die räumlich aufgelöste Messung von Gammastrahlen bereits zentraler Bestandteil der nuklearmedizinischen Bildgebung, jedoch sind die technischen Anforderungen der Strahlendetektion während der Teilchentherapie im Vergleich mit klassischen Anwendungen weitaus anspruchsvoller. Über den Stand der Technik hinaus müssen für diesen Zweck geeignete Instrumente zur Erfassung der prompten Gammastrahlen entwickelt und erprobt werden. Die elektrotechnische Realisierung bestimmt maßgeblich den Erfolg eines Verfahrens zur Reichweitenkontrolle von Teilchenstrahlen. Konkret bedeutet dies, dass ein geeignetes Detektormaterial mit angepasster Ausleseelektronik, Signal- und Informationsverarbeitung sowie Datenschnittstelle zur Problemlösung eingesetzt werden muss. Damit können die Parameter des Systems (z. B. Segmentierung, Zeit- oder Energieauflösung) in Abhängigkeit der Methode (z.B. Schlitzkamera, Flugzeitmessung oder Compton-Kamera) optimiert werden. Unabhängig vom Verfahren muss das Detektorsystem eine hohe Ratenfestigkeit und einen großen Messbereich (>7 MeV) besitzen. Für die anschließende Evaluierung eines geeigneten Verfahrens zur Bildgebung dürfen die genannten Parameter durch die Elektronik nicht eingeschränkt werden. Eine digitale Signalverarbeitung ist für universelle Aufgaben prädestiniert und die Leistungsfähigkeit einer solchen Implementierung soll hinsichtlich der gestellten Anforderungen bestimmt werden.
Material und Methode: Die Instrumentierung eines Detektorsystems für prompte Gammastrahlen beschränkt sich in dieser Arbeit auf die Anwendung eines Cadmiumzinktellurid (CdZnTe, CZT) Halbleiterdetektors. Der Detektorkristall ist durch segmentierte Elektroden in ein 8x8 Pixelarray geteilt. Die analoge und digitale Signalverarbeitung wird beispielhaft mit diesem Detektortyp erprobt und zielt auf die Anwendung zur Reichweitenkontrolle mit einer Compton-Kamera. Die Elektronik wird mit seriengefertigten integrierten Schaltkreisen umgesetzt. Soweit möglich, werden die Funktionseinheiten des Detektorsystems digitalisiert und in einem field-programmable gate array (FPGA) implementiert. Eine effiziente Umsetzung der Algorithmen in Bezug auf Zeitverhalten und Logikverbrauch ist grundlegend für den Entwurf der digitalen Schaltungen. Das Messsystem wird mit radioaktiven Prüfstrahlern hinsichtlich Messbereichsdynamik und Auflösung charakterisiert. Schließlich wird die Leistungsfähigkeit hinsichtlich der Anforderungen der Teilchentherapie mit Experimenten am Teilchenbeschleuniger untersucht.
Ergebnisse: Es wurde ein Detektorsystem auf Basis von CZT Pixeldetektoren entwickelt und erprobt. Obwohl der Einsatz einer anwendungsspezifischen integrierten Schaltung zweckmäßig wäre, wurde dieser Ansatz zurückgewiesen, da kein verfügbarer Schaltkreis die Anforderungen erfüllte. Stattdessen wurde eine vielkanalige, kompakte und rauscharme analoge Verstärkerschaltung mit seriengefertigten integrierten Schaltkreisen aufgebaut. Letztendlich werden die 65 Informationskanäle eines Detektors digitalisiert, verarbeitet und visualisiert. Eine fortschrittliche digitale Signalverarbeitung überführt die traditionellen Ansätze der Nuklearelektronik in Algorithmen und digitale Filterstrukturen für einen FPGA. Es konnte gezeigt werden, dass die digitale Pulsverarbeitung in Bezug auf die charakteristischen Signale (u.a. variierende Anstiegszeiten, tiefenabhängige Energiemessung) eines CZT Pixeldetektors eine sehr gute Energieauflösung (~2% FWHM at 511 keV) sowie eine Zeitmessung im Bereich von einigen 10 ns ermöglicht. Weiterhin haben die experimentellen Ergebnisse gezeigt, dass der Dynamikbereich des Detektorsystems im Vergleich zum bestehenden Prototyp der Compton-Kamera deutlich verbessert werden konnte (~10 keV..7 MeV). Nach allem konnten auch Zählraten von >100 kcps in einem hochenergetischen Strahl mit dem CZT Pixeldetektor verarbeitet werden. Dies stellt aber lediglich eine Begrenzung des Detektors aufgrund seines Volumens, nicht jedoch der Elektronik, dar. Zudem wurde die Vielseitigkeit der digitalen Signalverarbeitung auch mit anderen Detektormaterialen (u.a. CeBr3) demonstriert. Mit Voraussicht auf einen hohen Datendurchsatz in einer verteilten Datenerfassung von mehreren Detektoren, wurde als Datenschnittstelle eine Gigabit Ethernet Verbindung implementiert.
Schlussfolgerung: Um die Leistungsfähigkeit eines CZT Pixeldetektors vollständig auszunutzen, ist eine digitale Signalverarbeitung zwingend notwendig. Ein entscheidender Vorteil des digitalen Ansatzes ist die einfache Handhabbarkeit in einem vielkanaligen System. Mit der Digitalisierung wurde ein notwendiger Schritt getan, um die Komplexität einer Compton-Kamera beherrschbar zu machen. Weiterhin zeigt die Technologiebewertung, dass ein CZT Pixeldetektor den Anforderungen der Teilchentherapie für die Messung prompter Gammastrahlen stand hält. Der bisher eingesetzte Streifendetektor muss zugunsten einer gesteigerten Effizienz und verbesserter Energieauflösung durch den Pixeldetektor ersetzt werden. Mit der Integration des entwickelten digitalen Detektorsystems in eine Compton-Kamera muss abschließend geprüft werden, ob dieses Verfahren für die Reichweitenkontrolle in der Teilchentherapie anwendbar ist. Auch wenn sich herausstellt, dass ein anderes Verfahren unter klinischen Bedingungen praktikabler ist, so kann auch dieses Detektorsystem von der gezeigten Instrumentierung eines digitalen Signalverarbeitungssystems profitieren.
|
14 |
Photocurrent Spectroscopy of CdS/Plastic, CdS/Glass, and ZnTe/GaAs Hetero-pairs Formed with Pulsed-laser DepositionAcharya, Krishna Prasad 01 July 2009 (has links)
No description available.
|
15 |
Instrumentation of CdZnTe detectors for measuring prompt gamma-rays emitted during particle therapyFödisch, Philipp 12 May 2017 (has links)
Background: The irradiation of cancer patients with charged particles, mainly protons and carbon ions, has become an established method for the treatment of specific types of tumors. In comparison with the use of X-rays or gamma-rays, particle therapy has the advantage that the dose distribution in the patient can be precisely controlled. Tissue or organs lying near the tumor will be spared. A verification of the treatment plan with the actual dose deposition by means of a measurement can be done through range assessment of the particle beam. For
this purpose, prompt gamma-rays are detected, which are emitted by the affected target volume during irradiation.
Motivation: The detection of prompt gamma-rays is a task related to radiation detection and measurement. Nuclear applications in medicine can be found in particular for in vivo diagnosis. In that respect the spatially resolved measurement of gamma-rays is an essential technique for nuclear imaging, however, technical requirements of radiation measurement during particle therapy are much more challenging than those of classical applications. For this purpose, appropriate instruments beyond the state-of-the-art need to be developed and tested for detecting prompt gamma-rays. Hence the success of a method for range assessment of particle beams is largely determined by the implementation of electronics. In practice, this means that a suitable detector material with adapted readout electronics, signal and information processing, and data interface must be utilized to solve the challenges. Thus, the parameters of the system (e.g. segmentation, time or energy resolution) can be optimized depending on the method (e.g. slit camera, time-of-flight measurement or Compton camera). Regardless of the method, the detector system must have a high count rate capability and a large measuring range (>7 MeV). For a subsequent evaluation of a suitable method for imaging, the mentioned parameters may not be restricted by the electronics. Digital signal processing is predestined for multipurpose tasks, and, in terms of the demands made, the performance of such an implementation has to be determined.
Materials and methods: In this study, the instrumentation of a detector system for prompt gamma-rays emitted during particle therapy is limited to the use of a cadmium zinc telluride (CdZnTe, CZT) semiconductor detector. The detector crystal is divided into an 8x8 pixel array by segmented electrodes. Analog and digital signal processing are exemplarily tested with this type of detector and aims for application of a Compton camera to range assessment. The electronics are implemented with commercial off-the-shelf (COTS) components. If applicable, functional units of the detector system were digitalized and implemented in a field-programmable gate array (FPGA). An efficient implementation of the algorithms in terms of timing and logic utilization is fundamental to the design of digital circuits. The measurement system is characterized with radioactive sources to determine the measurement dynamic range and resolution. Finally, the performance is examined in terms of the requirements of particle therapy with experiments at particle accelerators.
Results: A detector system based on a CZT pixel detector has been developed and tested. Although the use of an application-specific integrated circuit is convenient, this approach was rejected because there was no circuit available which met the requirements. Instead, a multichannel, compact, and low-noise analog amplifier circuit with COTS components has been implemented. Finally, the 65 information channels of a detector are digitized, processed and visualized.
An advanced digital signal processing transforms the traditional approaches of nuclear electronics in algorithms and digital filter structures for an FPGA. With regard to the characteristic signals (e.g. varying rise times, depth-dependent energy measurement) of a CZT pixel detector, it could be shown that digital pulse processing results in a very good energy resolution (~2% FWHM at 511 keV), as well as permits a time measurement in the range of some tens of nanoseconds. Furthermore, the experimental results have shown that the dynamic range of the detector system could be significantly improved compared to the existing prototype of the Compton camera (~10 keV..7 MeV). Even count rates of ~100 kcps in a high-energy beam could be ultimately processed with the CZT pixel detector. But this is merely a limit of the detector due to its volume, and not related to electronics. In addition, the versatility of digital signal processing has been demonstrated with other detector materials (e.g. CeBr3). With foresight on high data throughput in a distributed data acquisition from multiple detectors, a Gigabit Ethernet link has been implemented as data interface.
Conclusions: To fully exploit the capabilities of a CZT pixel detector, a digital signal processing is absolutely necessary. A decisive advantage of the digital approach is the ease of use in a multichannel system. Thus with digitalization, a necessary step has been done to master the complexity of a Compton camera. Furthermore, the benchmark of technology shows that a CZT pixel detector withstands the requirements of measuring prompt gamma-rays during particle therapy. The previously used orthogonal strip detector must be replaced by the pixel detector in favor of increased efficiency and improved energy resolution. With the integration of the developed digital detector system into a Compton camera, it must be ultimately proven whether this method is applicable for range assessment in particle therapy. Even if another method is more convenient in a clinical environment due to practical considerations, the detector system of that method may benefit from the shown instrumentation of a digital signal processing system for nuclear applications.:1. Introduction
1.1. Aim of this work
2. Analog front-end electronics
2.1. State-of-the-art
2.2. Basic design considerations
2.2.1. CZT detector assembly
2.2.2. Electrical characteristics of a CZT pixel detector
2.2.3. High voltage biasing and grounding
2.2.4. Signal formation in CZT detectors
2.2.5. Readout concepts
2.2.6. Operational amplifier
2.3. Circuit design of a charge-sensitive amplifier
2.3.1. Circuit analysis
2.3.2. Charge-to-voltage transfer function
2.3.3. Input coupling of the CSA
2.3.4. Noise
2.4. Implementation and Test
2.5. Results
2.5.1. Test pulse input
2.5.2. Pixel detector
2.6. Conclusion
3. Digital signal processing
3.1. Unfolding-synthesis technique
3.2. Digital deconvolution
3.2.1. Prior work
3.2.2. Discrete-time inverse amplifier transfer function
3.2.3. Application to measured signals
3.2.4. Implementation of a higher order IIR filter
3.2.5. Conclusion
3.3. Digital pulse synthesis
3.3.1. Prior work
3.3.2. FIR filter structures for FPGAs
3.3.3. Optimized fixed-point arithmetic
3.3.4. Conclusion
4. Data interface
4.1. State-of-the-art
4.2. Embedded Gigabit Ethernet protocol stack
4.3. Implementation
4.3.1. System overview
4.3.2. Media Access Control
4.3.3. Embedded protocol stack
4.3.4. Clock synchronization
4.4. Measurements and results
4.4.1. Throughput performance
4.4.2. Synchronization
4.4.3. Resource utilization
4.5. Conclusion
5. Experimental results
5.1. Digital pulse shapers
5.1.1. Spectroscopy application
5.1.2. Timing applications
5.2. Gamma-ray spectroscopy
5.2.1. Energy resolution of scintillation detectors
5.2.2. Energy resolution of a CZT pixel detector
5.3. Gamma-ray timing
5.3.1. Timing performance of scintillation detectors
5.3.2. Timing performance of CZT pixel detectors
5.4. Measurements with a particle beam
5.4.1. Bremsstrahlung Facility at ELBE
6. Discussion
7. Summary
8. Zusammenfassung / Hintergrund: Die Bestrahlung von Krebspatienten mit geladenen Teilchen, vor allem Protonen oder Kohlenstoffionen, ist mittlerweile eine etablierte Methode zur Behandlung von speziellen Tumorarten. Im Vergleich mit der Anwendung von Röntgen- oder Gammastrahlen hat die Teilchentherapie den Vorteil, dass die Dosisverteilung im Patienten präziser gesteuert werden kann. Dadurch werden um den Tumor liegendes Gewebe oder Organe geschont. Die messtechnische Verifikation des Bestrahlungsplans mit der tatsächlichen Dosisdeposition kann über eine Reichweitenkontrolle des Teilchenstrahls erfolgen. Für diesen Zweck werden prompte Gammastrahlen detektiert, die während der Bestrahlung vom getroffenen Zielvolumen emittiert werden.
Fragestellung: Die Detektion von prompten Gammastrahlen ist eine Aufgabenstellung der Strahlenmesstechnik. Strahlenanwendungen in der Medizintechnik finden sich insbesondere in der in-vivo Diagnostik. Dabei ist die räumlich aufgelöste Messung von Gammastrahlen bereits zentraler Bestandteil der nuklearmedizinischen Bildgebung, jedoch sind die technischen Anforderungen der Strahlendetektion während der Teilchentherapie im Vergleich mit klassischen Anwendungen weitaus anspruchsvoller. Über den Stand der Technik hinaus müssen für diesen Zweck geeignete Instrumente zur Erfassung der prompten Gammastrahlen entwickelt und erprobt werden. Die elektrotechnische Realisierung bestimmt maßgeblich den Erfolg eines Verfahrens zur Reichweitenkontrolle von Teilchenstrahlen. Konkret bedeutet dies, dass ein geeignetes Detektormaterial mit angepasster Ausleseelektronik, Signal- und Informationsverarbeitung sowie Datenschnittstelle zur Problemlösung eingesetzt werden muss. Damit können die Parameter des Systems (z. B. Segmentierung, Zeit- oder Energieauflösung) in Abhängigkeit der Methode (z.B. Schlitzkamera, Flugzeitmessung oder Compton-Kamera) optimiert werden. Unabhängig vom Verfahren muss das Detektorsystem eine hohe Ratenfestigkeit und einen großen Messbereich (>7 MeV) besitzen. Für die anschließende Evaluierung eines geeigneten Verfahrens zur Bildgebung dürfen die genannten Parameter durch die Elektronik nicht eingeschränkt werden. Eine digitale Signalverarbeitung ist für universelle Aufgaben prädestiniert und die Leistungsfähigkeit einer solchen Implementierung soll hinsichtlich der gestellten Anforderungen bestimmt werden.
Material und Methode: Die Instrumentierung eines Detektorsystems für prompte Gammastrahlen beschränkt sich in dieser Arbeit auf die Anwendung eines Cadmiumzinktellurid (CdZnTe, CZT) Halbleiterdetektors. Der Detektorkristall ist durch segmentierte Elektroden in ein 8x8 Pixelarray geteilt. Die analoge und digitale Signalverarbeitung wird beispielhaft mit diesem Detektortyp erprobt und zielt auf die Anwendung zur Reichweitenkontrolle mit einer Compton-Kamera. Die Elektronik wird mit seriengefertigten integrierten Schaltkreisen umgesetzt. Soweit möglich, werden die Funktionseinheiten des Detektorsystems digitalisiert und in einem field-programmable gate array (FPGA) implementiert. Eine effiziente Umsetzung der Algorithmen in Bezug auf Zeitverhalten und Logikverbrauch ist grundlegend für den Entwurf der digitalen Schaltungen. Das Messsystem wird mit radioaktiven Prüfstrahlern hinsichtlich Messbereichsdynamik und Auflösung charakterisiert. Schließlich wird die Leistungsfähigkeit hinsichtlich der Anforderungen der Teilchentherapie mit Experimenten am Teilchenbeschleuniger untersucht.
Ergebnisse: Es wurde ein Detektorsystem auf Basis von CZT Pixeldetektoren entwickelt und erprobt. Obwohl der Einsatz einer anwendungsspezifischen integrierten Schaltung zweckmäßig wäre, wurde dieser Ansatz zurückgewiesen, da kein verfügbarer Schaltkreis die Anforderungen erfüllte. Stattdessen wurde eine vielkanalige, kompakte und rauscharme analoge Verstärkerschaltung mit seriengefertigten integrierten Schaltkreisen aufgebaut. Letztendlich werden die 65 Informationskanäle eines Detektors digitalisiert, verarbeitet und visualisiert. Eine fortschrittliche digitale Signalverarbeitung überführt die traditionellen Ansätze der Nuklearelektronik in Algorithmen und digitale Filterstrukturen für einen FPGA. Es konnte gezeigt werden, dass die digitale Pulsverarbeitung in Bezug auf die charakteristischen Signale (u.a. variierende Anstiegszeiten, tiefenabhängige Energiemessung) eines CZT Pixeldetektors eine sehr gute Energieauflösung (~2% FWHM at 511 keV) sowie eine Zeitmessung im Bereich von einigen 10 ns ermöglicht. Weiterhin haben die experimentellen Ergebnisse gezeigt, dass der Dynamikbereich des Detektorsystems im Vergleich zum bestehenden Prototyp der Compton-Kamera deutlich verbessert werden konnte (~10 keV..7 MeV). Nach allem konnten auch Zählraten von >100 kcps in einem hochenergetischen Strahl mit dem CZT Pixeldetektor verarbeitet werden. Dies stellt aber lediglich eine Begrenzung des Detektors aufgrund seines Volumens, nicht jedoch der Elektronik, dar. Zudem wurde die Vielseitigkeit der digitalen Signalverarbeitung auch mit anderen Detektormaterialen (u.a. CeBr3) demonstriert. Mit Voraussicht auf einen hohen Datendurchsatz in einer verteilten Datenerfassung von mehreren Detektoren, wurde als Datenschnittstelle eine Gigabit Ethernet Verbindung implementiert.
Schlussfolgerung: Um die Leistungsfähigkeit eines CZT Pixeldetektors vollständig auszunutzen, ist eine digitale Signalverarbeitung zwingend notwendig. Ein entscheidender Vorteil des digitalen Ansatzes ist die einfache Handhabbarkeit in einem vielkanaligen System. Mit der Digitalisierung wurde ein notwendiger Schritt getan, um die Komplexität einer Compton-Kamera beherrschbar zu machen. Weiterhin zeigt die Technologiebewertung, dass ein CZT Pixeldetektor den Anforderungen der Teilchentherapie für die Messung prompter Gammastrahlen stand hält. Der bisher eingesetzte Streifendetektor muss zugunsten einer gesteigerten Effizienz und verbesserter Energieauflösung durch den Pixeldetektor ersetzt werden. Mit der Integration des entwickelten digitalen Detektorsystems in eine Compton-Kamera muss abschließend geprüft werden, ob dieses Verfahren für die Reichweitenkontrolle in der Teilchentherapie anwendbar ist. Auch wenn sich herausstellt, dass ein anderes Verfahren unter klinischen Bedingungen praktikabler ist, so kann auch dieses Detektorsystem von der gezeigten Instrumentierung eines digitalen Signalverarbeitungssystems profitieren.:1. Introduction
1.1. Aim of this work
2. Analog front-end electronics
2.1. State-of-the-art
2.2. Basic design considerations
2.2.1. CZT detector assembly
2.2.2. Electrical characteristics of a CZT pixel detector
2.2.3. High voltage biasing and grounding
2.2.4. Signal formation in CZT detectors
2.2.5. Readout concepts
2.2.6. Operational amplifier
2.3. Circuit design of a charge-sensitive amplifier
2.3.1. Circuit analysis
2.3.2. Charge-to-voltage transfer function
2.3.3. Input coupling of the CSA
2.3.4. Noise
2.4. Implementation and Test
2.5. Results
2.5.1. Test pulse input
2.5.2. Pixel detector
2.6. Conclusion
3. Digital signal processing
3.1. Unfolding-synthesis technique
3.2. Digital deconvolution
3.2.1. Prior work
3.2.2. Discrete-time inverse amplifier transfer function
3.2.3. Application to measured signals
3.2.4. Implementation of a higher order IIR filter
3.2.5. Conclusion
3.3. Digital pulse synthesis
3.3.1. Prior work
3.3.2. FIR filter structures for FPGAs
3.3.3. Optimized fixed-point arithmetic
3.3.4. Conclusion
4. Data interface
4.1. State-of-the-art
4.2. Embedded Gigabit Ethernet protocol stack
4.3. Implementation
4.3.1. System overview
4.3.2. Media Access Control
4.3.3. Embedded protocol stack
4.3.4. Clock synchronization
4.4. Measurements and results
4.4.1. Throughput performance
4.4.2. Synchronization
4.4.3. Resource utilization
4.5. Conclusion
5. Experimental results
5.1. Digital pulse shapers
5.1.1. Spectroscopy application
5.1.2. Timing applications
5.2. Gamma-ray spectroscopy
5.2.1. Energy resolution of scintillation detectors
5.2.2. Energy resolution of a CZT pixel detector
5.3. Gamma-ray timing
5.3.1. Timing performance of scintillation detectors
5.3.2. Timing performance of CZT pixel detectors
5.4. Measurements with a particle beam
5.4.1. Bremsstrahlung Facility at ELBE
6. Discussion
7. Summary
8. Zusammenfassung
|
16 |
Simulation and growth of cadmium zinc telluride from small seeds by the travelling heater methodRoszmann, Jordan Douglas 08 June 2017 (has links)
The semiconducting compounds CdTe and CdZnTe have important applications in high-energy radiation detectors and as substrates for infrared devices. The materials offer large band gaps, high resistivity, and excellent charge transport properties; however all of these properties rely on very precise control of the material composition. Growing bulk crystals by the travelling heater method (THM) offers excellent compositional control and fewer defects compared to gradient freezing, but it is also much slower and more expensive. A particular challenge is the current need to grow new crystals onto existing seeds of similar size and quality.
Simulations and experiments are used in this work to investigate the feasibility of growing these materials by THM without the use of large seed crystals. A new fixed-grid, multiphase finite element model was developed based on the level set method and used to calculate the mass transport regime and interface shapes inside the growth ampoule. The diffusivity of CdTe in liquid tellurium was measured through dissolution experiments, which also served to validate the model. Simulations of tapered THM growth find conditions similar to untapered growth with interface shapes that are sensitive to strong thermosolutal convection. Favourable growth conditions are achievable only if convection can be controlled.
In preliminary experiments, tapered GaSb crystals were successfully grown by THM and large CdTe grains were produced by gradient freezing. Beginning with this seed material, 25 mm diameter CdTe and CdZnTe crystals were grown on 10 mm diameter seeds, and 65 mm diameter CdTe on 25 mm seeds. Unseeded THM growth was also investigated, as well as ampoule rotation and a range of thermal conditions and ampoule surface coatings. Outward growth beyond one or two centimeters was achieved only at small diameters and included secondary grains and twin defects; however, limited outward growth of larger seeds and agreement between experimental and numerical results suggest that tapered growth may be achievable in the future. This would require active temperature control at the base of the crystal and reduction of convection through thermal design or by rotation of the ampoule or applied magnetic fields. / Graduate / 0346 / 0794 / 0548 / jordan.roszmann@gmail.com
|
Page generated in 0.0686 seconds