1 |
Estudo de modificadores quimicos e superficies modificadas para a determinação de estanho por espectrometria de absorção atomica com forno de grafiteAnjos, Aparecida Pereira dos, 1963- 22 July 2018 (has links)
Orientador: Nivaldo Baccan / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-22T04:00:58Z (GMT). No. of bitstreams: 1
Anjos_AparecidaPereirados_D.pdf: 4904249 bytes, checksum: cb06ac4570499209e19497178e2f9827 (MD5)
Previous issue date: 1997 / Doutorado
|
2 |
Pre-concentração de cobalto utlizando resina Amberlyst A-26 modificada com morfolinaditiocarbamato de amonio e determinação por espectrometria de absorção atomicaGoi, Rosemary Dias 24 July 2018 (has links)
Orientador: Solange Cadore / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-24T07:26:11Z (GMT). No. of bitstreams: 1
Goi_RosemaryDias_M.pdf: 1512831 bytes, checksum: a11328307fce5dc8968d53d527943259 (MD5)
Previous issue date: 1998 / Mestrado
|
3 |
Determinação de chumbo em amostras ambientais certificadas por LS-GF AAS e por HR-CS GF AASSilva, Jessee Severo Azevedo January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-22T12:20:30Z (GMT). No. of bitstreams: 1
226904.pdf: 692138 bytes, checksum: 7382d2a064197adbdceae1968ae55dd4 (MD5) / São apresentadas metodologias para determinação de Pb em amostras ambientais por espectrometria de absorção atômica com atomização em forno de grafite (GF AAS) e de alta resolução com fonte contínua (HR-CS AAS) utilizando análise direta de sólidos e do sólido em suspensão. Com a técnica de GF AAS, para a análise direta do sólido, temperaturas de 700 ºC e 1700 ºC para pirólise e atomização, respectivamente, foram otimizadas.Ru foi usado como modificador permanente. O método apresentou boas precisão e exatidão. Para análises em suspensões, amostras certificadas em meio de HNO3 e HF foram usadas. Temperaturas de pirólise e atomização ideais foram 700 ºC e 1700 ºC, respectivamente. Foram usados Ru foi como modificador permanente e calibração externa com padrões aquosos. As análises apresentaram boas precisão e exatidão. Em um estudo paralelo, realizado em HR-CS AAS, as análises foram isentas de interferências, confirmando a confiabilidade do método. Como HR-CS AAS possibilita uma poderosa correção de fundo, uma visualização de todo o ambiente nas vizinhanças da linha analítica e o uso de linhas analíticas secundárias, um estudo foi realizado, para estabelecimento de método de análise de Pb utilizando a linha analítica 217,0 nm, e obteve-se um aumento na sensibilidade e na precisão, quando comparado com as determinações efetuadas em 283,3 nm. Otimizações foram realizadas em suspensões de amostras certificadas em meio de HNO3 e HF. Temperaturas de 700 ºC e 1700 ºC, pirólise e atomização, respectivamente, e modificador permanente foram usadas determinações com calibração externa com padrões aquosos.
|
4 |
Desenvolvimento de métodos para a determinação de selênio em solo por espectrometria de absorção atômicaCastilho, Ivan Nikolai Barkow January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, 2016. / Made available in DSpace on 2016-10-25T03:09:12Z (GMT). No. of bitstreams: 1
342314.pdf: 1401935 bytes, checksum: d1851ccd1b9b72b68ec77ba13c6c9996 (MD5)
Previous issue date: 2016 / A primeira parte deste trabalho descreve o desenvolvimento de método para a determinação de Se em amostras de solo usando espectrometria de absorção atômica de alta resolução com fonte contínua em forno de grafite e análise direta de sólidos. A linha de absorção mais sensível em 196,026 nm foi usada para todas as determinações. Rutênio, além de ser depositado na plataforma como modificador permanente, também foi adicionado em solução em cada amostra sólida. Todas as amostras sólidas mostraram um fundo estruturado causado pelas moléculas de NO e PO. Espectros de referência dessas moléculas foram gravados usando ácido nítrico e fosfórico, respectivamente, que em seguida foram utilizados para a correção de fundo por mínimos quadrados. Os limites de detecção e quantificação foram 30 ng g-1 Se e 100 ng g-1 Se, respectivamente. As amostras de solo foram coletadas em áreas rurais experimentais nãotratadas (sem a adição de fertilizantes) a fim de obter valores representativos da distribuição natural de Se. Regiões apropriadas para amostragem foram selecionadas em 12 dos 27 Estados brasileiros, cobrindo 61% da área total do país. Os resultados dos materiais de referência certificados MURST-ISS-A1, MESS-3 e PACS-2 (todos de sedimentos marinhos) confirmaram a exatidão do método proposto. O Se encontrado nas amostras variou entre 130 ± 10 ng g-1 e 630 ± 15 ng g-1. A repetitividade das medidas foi entre 3 e 10% (n = 5). Uma segunda parte deste trabalho apresenta valores de Se em todas as amostras de solo que foram coletadas na amostragem de 12 dos 27 Estados brasileiros. A campanha se baseou em áreas rurais experimentais não-tratadas, com 10 pontos de coleta em cada área, cada um deles dividido em três níveis de profundidade. O Se encontrado nas amostras variou entre 0,1 ± 0,05 µg g-1 e 19,0 ± 3,0 µg g-1. A repetitividade das medidas foi entre 3 e 10% (n = 3). O valor de Se diminuiu conforme a profundidade das amostras coletadas. Finalmente, a terceira parte deste trabalho é a proposta de um simples procedimento para a determinação de espécies de Se em amostras de solo usando extração alcalina com banho de ultrassom e espectrometria de absorção atômica com geração de hidretos, conhecida por ser uma determinação específica de apenas Se(IV). O hidreto foi aprisionado e atomizado em um tubo de forno de grafite recoberto por irídio como modificador químico permanente. Os limites de detecção e quantificação para o método desenvolvido foram de 6 µg L-1 e 20 µg L-1 Se(IV), respectivamente. O conteúdo total de Se nas amostras com extração alcalina foi determinado aplicando o método desenvolvido anteriormente com a espectrometria de absorção atômica de alta resolução e com fonte contínua. O conteúdo de Se(VI) foi calculado pela diferença entre o Se total e Se(IV). A eficiência de extração foi verificada comparando os resultados obtidos pela extração alcalina e por análise direta de sólidos. A exatidão do método para Se total foi verificada usando tanto digestão ácida por micro-ondas, quanto análise direta de sólidos, em um espectrômetro de absorção atômica de alta resolução com fonte contínua com os materiais certificados de
referência MURST-ISS-A1 e BCR 142R, assim como as amostras de solo de diferentes regiões do Brasil.<br> / Abstract : The first part of this work presents a method developed for the determination of Se in soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis. The most sensitive absorption line at 196.026 nm has been used for all determinations. Ruthenium, apart from being deposited on the platform as permanent modifier, was also added in solution on top of each solid sample. All soil samples exhibited a fine structured background caused primarily by the NO and PO molecules. Reference spectra of these molecules were recorded using nitric and phosphoric acid, respectively, which were used for least squares background correction. The limits of detection and quantification were 30 ng g-1 and 100 ng g-1 Se, respectively. Soil samples were collected from untreated experimental farming areas (without addition of fertilizers) in order to
obtain representative values of natural Se distribution. Appropriate areas for sampling were selected in 12 of the 27 Brazilian States, covering 61% of the total area of the country. The results of the Certified
Reference Materials MURST-ISS-A1, MESS-3 and PACS-2 Marine Sediments confirmed the validity of the proposed method. The Se content found in the soil samples varied between 130 ± 10 ng g-1 and 630 ± 15 ng g-1. The repeatability of the measurements was between 3% and 10% (n = 5). The second part of this work shows values of Se on all soil samples that were available from the collecting campaign in 12
Brazilian States. The campaign was based on untreated experimental farming areas, 10 sampling points on each area, where each point was divided on three different levels of depth. The Se content found in the
soil samples varied between 0.1 ± 0.05 µg g-1 and 19.0 ± 3.0 µg g-1. The repeatability of the measurements was between 3% and 10% (n = 3). The Se content was lower for samples collected from deeper levels. Finally, the third part of this work is the proposal of a simple procedure for the determination of Se species in soil samples using an ultrasound-assisted alkaline extraction and hydride generation atomic absorption spectrometry, which is known to be specific for the determination of Se(IV) only. The hydride was trapped and atomized in a graphite tube furnace coated with iridium as a permanent chemical modifier. The limits of detection and quantification for the developed method were 6 µg L-1 and 20 µg L-1 Se(IV), respectively. The total Se content in the samples was determined in the alkaline extract using the
same method developed previously with high-resolution continuum source graphite furnace atomic absorption spectrometry, and the content of Se(VI) was determined by difference between the total Se and the content of Se(IV). The extraction efficiency was verified by comparing the results obtained by the alkaline extraction and by direct solid sample analysis. The accuracy of the method for total Se determination was ascertained using microwave-assisted acid digestion, as well direct solid
sample analysis of the certified reference materials MURST-ISS-A1 and BCR 142R, and soil samples from different regions of Brazil.
|
5 |
Pre-concentração e determinação de selenio por espectrometria de absorção atomica com geração de hidreto em um sistema de analise por injeção em fluxoCoelho, Nivia Maria Melo 21 July 2018 (has links)
Orientador: Nivaldo Baccan / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-21T02:58:12Z (GMT). No. of bitstreams: 1
Coelho_NiviaMariaMelo_D.pdf: 3027974 bytes, checksum: 9538235be9bed071e20ea4921c009633 (MD5)
Previous issue date: 1995 / Doutorado
|
6 |
Caracterização cristaloquimica da incorporação de ions cobre (II) em Goethita (alfa-FeOOH) sinteticaNetto, Silvania Maria 28 July 2018 (has links)
Orientadores : Jacinta Enzweiler, Maria Luiza Melchert de Carvalho e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-07-28T10:07:45Z (GMT). No. of bitstreams: 1
Netto_SilvaniaMaria_D.pdf: 5376253 bytes, checksum: 51c270cd612675bdc73bda8018d8508a (MD5)
Previous issue date: 2001 / Doutorado
|
7 |
Estudo analitico da extração liquido-solido para pre-concentração de metais utilizando o sistema FEN/SDS/XAD-2 e determinação por espectrometria de absorção atomica com chamaCastro, Martha Teresa Pantoja de Oliveira 01 August 2018 (has links)
Orientador : Nivaldo Baccan / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-01T20:42:49Z (GMT). No. of bitstreams: 1
Castro_MarthaTeresaPantojadeOliveira_D.pdf: 4031690 bytes, checksum: d7cf04e3e7e2eeba30977edbb01818be (MD5)
Previous issue date: 2002 / Doutorado
|
8 |
Sintese e algumas propriedades de oligo e polissilarilenosMori, Marcello Nunes 14 July 2018 (has links)
Orientador : Inez Valeria P. Yoshida / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-14T00:05:33Z (GMT). No. of bitstreams: 1
Mori_MarcelloNunes_M.pdf: 7394580 bytes, checksum: 35ec26b0fce7c35faa1e45665bdb9370 (MD5)
Previous issue date: 1991 / Mestrado
|
9 |
Espectroscopia optogalvânica em lâmpadas de catodo OCO contendo argônioCosta, Cesar Gustavo Silveira da 10 November 1989 (has links)
Orientador: Artemio Scalabrin / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T01:05:43Z (GMT). No. of bitstreams: 1
Costa_CesarGustavoSilveirada_M.pdf: 3920033 bytes, checksum: 59a6b7e34b97fadc7445caa92eb5b4b6 (MD5)
Previous issue date: 1989 / Resumo: Neste trabalho utilizamos o efeito optogalvânico, isto é, a variação fotoinduzida da impedância de um plasma, aplicado ao estudo espectroscópico de um gás nobre, o argônio, e de átomos metálicos, cobre e urânio pulverizados na descarga, em lâmpadas de cátodo oco.
São utilizadas lâmpadas seladas ou com conteúdo reciclável, caracterizadas através da espectroscopia de emissão, que se constitui em valoroso auxilio na identificação das linhas do espectro optogalvânico, além de fornecer indicações seguras quanto à contaminação de amostras. É analisado o comportamento do sinal optogalvânico dos ions do argônio, obtido através da sintonização de linhas do laser de argônio, em função da potência do laser e da corrente na lâmpada. São apresentados espectros optogalvânicos do argônio, acompanhado de linhas do vapor catódico (cobre e urânio), obtidos com a varredura em comprimentos de onda através de um laser de corante CW, com Rhodamina 6G (57O-62Onm). E constata-se uma sensibilidade maior do que a espectroscopia de emissão, na detecção de linhas do gás. A evolução do sinal optogalvânico com a corrente na lâmpada, operada entre 5 e 20mA, pode revelar a competição entre os processos de excitação, depopulação, ionização e recombinação das espécies na descarga, tomando por base as teorias e os mecanismos formulados para o efeito nos últimos 15 anos. A comparação da magnitude do sinal com a intensidade do espectro de emissão, testada para o argônio e o urânio, fornece elementos novos que precisam ser analisados, tendo em vista a polêmica lançada sobre uma possível correlação quantitativa entre os dois fenômenos. Supondo a validade desta correspondência, efetua-se uma estimativa da temperatura eletrônica do plasma, sob diferentes condições, que é então confrontada com outros valores medidos, típicos a essa classe de descargas. Finalmente, são examinados alguns desdobramentos para a pesquisa desenvolvida, com vistas a aplicações futuras / Abstract: Not informed. / Mestrado / Física / Mestre em Física
|
10 |
Quantificação de baixos teores de selenio em alimentos por espectrometria de absorção atomica com atomização eletrotermicaDias, Vera Maria da Costa 03 August 2018 (has links)
Orientadores : Nivaldo Baccan, Solange Cadore / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T15:24:31Z (GMT). No. of bitstreams: 1
Dias_VeraMariadaCosta_D.pdf: 3913829 bytes, checksum: 37f6784fb5950cd92289b5b9695576a5 (MD5)
Previous issue date: 2002 / Doutorado
|
Page generated in 0.0704 seconds