• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 1
  • Tagged with
  • 212
  • 212
  • 139
  • 78
  • 76
  • 43
  • 41
  • 40
  • 39
  • 38
  • 37
  • 37
  • 30
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Desenvolvimento de nova metodologia para extração de cádmio (II) utilizando sistema de extração com membrana líquida renovável e detecção por espectrometria de absorção atômica em chama

Carletto, Jeferson Schneider 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Quimica, Florianópolis, 2009. / Made available in DSpace on 2012-10-24T14:30:32Z (GMT). No. of bitstreams: 1 275105.pdf: 1405556 bytes, checksum: dc4368431d8c2a68762e7f4f84fe400c (MD5) / A hollow fiber renewal liquid membrane (HFRLM) extraction method for determination of cadmium(II) in water samples by Flame Atomic Absorption Spectrometry (FAAS) was developed. Ammonium O,O-diethyl dithiophosphate (DDTP) was used to complex cadmium(II) in an acid pH into a neutral hydrofobic complex (ML2). A solvent extract this complex and carry it over the Poly(dimethylsiloxane) (PDMS) or polypropylene membrane to the stripping phase into the membrane, where at higher pH the complex Cd-DDTP is broken out and cadmium(II) is released into the stripping phase. EDTA was used to complex cadmium(II) helping to trap the analyte into the stripping phase. Multivariate optimization using surface response metodology was used to optimize the studied variables: sample (donor phase) pH 3.25, DDTP concentration 0.05% (m/v), stripping (aceptor phase) pH 8.75, EDTA concentration 1.5x10-2 mol L-1, extraction temperature 40°C, extraction time 40 minutes, a solvent mixture of N-Butyl Acetate and Hexane (60/40% v/v) with volume of 100 ìL and adition of ammonium sulphate to saturate the sample for PDMS membrane. For polypropylene membrane the optimized conditions were: sample (donor phase) pH 3.5, DDTP concentration 0.06% (m/v), stripping (aceptor phase) pH 9.0, EDTA concentration 6.3 x 10-3 mol L-1, extraction temperature 36°C, extraction time 36 minutes, toluene as solvent extractor with volume of 300 ìL and adition of ammonium sulphate to saturate the sample. The sample volume and stripping volume used were 20 mL and 165 ìL, respectivaly. The analyte enrichment factor was 115, limit of detection (LOD) 1.3 ìg L-1, relative standard deviation (RSD) 5.5 % and linear working range 4.5 - 30 ìg L-1 for PDMS membrane. For polypropylene membrane the analyte enrichment factor was 107, limit of detection (LOD) 1.5 ìg L-1, relative standard deviation (RSD) 4 % and linear woking range 5.1 - 30 ìg L.
42

Determinação de elementos traço em diesel e biodiesel por espectrometria de absorção atômica de alta resolução com fonte contínua e atomização eletrotérmica

Quadros, Daiane Paula Cunha de January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T22:23:31Z (GMT). No. of bitstreams: 1 289610.pdf: 866294 bytes, checksum: 532f7e63a97238dd39c594db0bd5da30 (MD5)
43

Desenvolvimento de método analítico para determinação de metais em biodiesel e óleo vegetal por espectometria de absorção atômica com chama

Jesus, Alexandre de January 2008 (has links)
Os metais sódio, potássio, magnésio e cálcio podem danificar a estabilidade do biodiesel, pois tendem a reagir com ésteres e produzir sabão. Neste trabalho foi desenvolvido um método para a determinação desses metais em amostras de biodiesel e óleo vegetal, através da microemulsificação das amostras e determinação por espectrometria de absorção atômica com chama (F AAS). Amostras de biodiesel obtidas de diferentes fontes e de óleo vegetal foram analisadas. Foram obtidas microemulsões do tipo óleo-em-água pela mistura de biodiesel ou óleo vegetal, um surfactante, água e um co-surfactante. Na fase aquosa das microemulsões, foram adicionados HNO3 diluído e padrões inorgânicos dos metais para calibração. Vantagens em relação ao método de diluição com solvente, que é o método oficial adotado para as determinações (método de referência) foram observadas, tais como: maior estabilidade dos analitos no meio microemulsificado, possibilidade de calibração usando padrões aquosos nas microemulsões, limites de quantificação melhores e não utilização de solventes orgânicos carcinogênicos. Os resultados obtidos pelo método proposto foram concordantes com os resultados obtidos pelo método de referência, tornando assim o novo método uma eficiente alternativa para a determinação de metais em biodiesel, além de suprir as deficiências apresentadas pelo método de diluição com solvente. / The metals sodium, potassium, magnesium and calcium can damage biodiesel stability because these metals tend to react with esters and produce soap. In this work a method was developed for the determination of these metals in biodiesel and vegetable oil samples, through microemulsification of the samples and determination by flame atomic absorption spectrometry (F AAS). Biodiesel samples obtained from different sources and vegetable oil samples were analyzed. The water-in-oil microemulsion systems were obtained mixing biodiesel, a surfactant, water and a co-surfactant. Inorganic standards were added within the water portion to prepare the microemulsions used for calibration and nitric acid. The proposed method was compared with the method adopted by Brazilian’s regulations of dilution with organic solvent (reference method) for these determinations and some advantages were observed, as: higher stability of analytes in the microemulsions, feasibility of calibration using aqueous standards in the microemulsions, better limits of quantification and no use carcinogenic solvents. The results obtained by the new proposed method were a good agreement with the results obtained by the reference method. The new proposed method was an efficient alternative for the determination of metals in biodiesel, and overcome some deficiencies presented by the dilution method.
44

Estratégias analíticas para análise de especiação de arsênio, antimônio e selênio em amostras ambientais usando amostragem por suspensão e HG AAS

Macedo, Samuel Marques January 2010 (has links)
101 f. / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-05T14:35:00Z No. of bitstreams: 1 Tese Samuel Marques Macedo.pdf: 1053150 bytes, checksum: be91e29f4ed99985c281e793d1f397c3 (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-05-09T12:37:12Z (GMT) No. of bitstreams: 1 Tese Samuel Marques Macedo.pdf: 1053150 bytes, checksum: be91e29f4ed99985c281e793d1f397c3 (MD5) / Made available in DSpace on 2013-05-09T12:37:12Z (GMT). No. of bitstreams: 1 Tese Samuel Marques Macedo.pdf: 1053150 bytes, checksum: be91e29f4ed99985c281e793d1f397c3 (MD5) Previous issue date: 2010 / CNPq / Um procedimento analítico simples e rápido foi desenvolvido para a determinação de As em amostras de sedimento e determinação de As, Sb e Se em amostras de material particulado atmosférico por geração de hidreto acoplado ao espectrômetro de absorção atômica (HG-AAS). Procedimentos de amostragem de suspensão foram avaliados quanto a determinação de As, Sb e Se inorgânicos por geração de hidreto acoplado a AAS, usando HCl e sonicação por 30 min. As amostras foram preparadas com KI e ácido ascórbico para determinação de As e Sb total e com HCl 8 mol L-1 em banho de ultra-som para a determinação de Se total. Para a determinação seletiva de As (III) foi usado tampão ácido cítrico/citrato, para Sb (III) foi usado ácido cítrico e Se (IV) foi determinado considerando que Se (VI) não forma hidreto. Suspensões das amostras foram tratadas com NaBH4 para obter o hidreto correspondente. O procedimento foi otimizado para taxa de fluxo de NaBH4, concentração de NaBH4 e HCl usando planejamento fatorial dois níveis completo e também um planejamento Box-Behnken para As e Sb e usando planejamento fatorial dois níveis completo para Se. A preparação das suspensões com HCl em ultra-som permitiu a determinação de As, Sb e Se total com limites de detecção de 0,1, 0,05 e 0,1 μg L−1, respectivamente e As (III), Sb (III) e Se (IV) com limites de detecção de 0,3, 0,1 e 0,3 μg L−1 respectivamente. A exatidão do método foi confirmada pela análise de materiais de referência certificado de sedimento marinho (MESS-2 e MESS-3) e poeira urbana (1649a), ao passo que o procedimento permite a calibração com padrões aquosos. Concentrações encontradas nas amostras variaram de 2,81 a 5,38 mg kg−1 para As total (RSD < 5 %), de 0,59 a 1,25 mg kg−1 para As (III) (RSD < 8%), em material particulado atmosférico variaram de 9,1 a 19,0 ng m−3 para As total (RSD < 4 %), de 2,7 a 11,0 ng m−3 As (III) (RSD < 5 %) e para Sb total variaram de 0,49 a 0,63 ng m−3 (RSD < 9 %). Nas amostras analisadas de material particulado atmosférico, as concentrações de Sb (III) ficaram abaixo do limite de quantificação. O selênio foi determinado somente no SRM 1649a. / Salvador
45

Espectrometria de ansorção atômica de alta resolução com fonte contínua como ferramenta analítica para o desenvolvimento de método para determinação de níquel e vanádio por espectrometria de absorção atômica em forno de grafite em amostras de óleo cru

Lepri, Fábio Grandis January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2013-07-16T02:46:04Z (GMT). No. of bitstreams: 1 242932.pdf: 655625 bytes, checksum: cb4ba88d1cd423bf1f47453296285b3d (MD5)
46

Desenvolvimento de métodos analíticos para a determinação de mercúrio e selênio utilizando técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite

Potes, Mariana da Luz January 2018 (has links)
A geração química de vapor (CVG) e a geração fotoquímica de vapor (PVG) são técnicas analíticas empregadas na conversão do analito, presente na fase condensada, em uma espécie volátil, previamente a sua introdução no sistema de detecção. Neste trabalho foram desenvolvidos procedimentos analíticos para a determinação de Hg e Se em amostras biológicas por técnicas de geração de vapor acopladas à espectrometria de absorção atômica com forno de grafite (GF AAS). A determinação exata e precisa de Hg em amostras de peixe foi possível após a solubilização em hidróxido de tetrametilamônio e adição de n-propanol, como composto orgânico de baixo peso molecular, e detecção por PVG-GF AAS. O método analítico desenvolvido com o emprego da técnica de PVG para a determinação de Se em água de coco por GF AAS resultou em limites de detecção e quantificação de 0,65 μg L-1 e 2,2 μg L-1, respectivamente, os quais foram semelhantes aos obtidos por CVG. Os métodos desenvolvidos para a determinação de Hg e Se por PVG-GF AAS em amostras biológicas são sensíveis, livres de interferência espectral, de baixo custo e representam uma alternativa viável a CVG. / Chemical vapor generation (CVG) and photochemical vapor generation (PVG) are analytical techniques used to convert the analyte into a volatile species in liquid phase, before the introduction into the detection system. In this study, analytical procedures for the determination of Hg and Se in biological samples by vapor generation techniques coupled to graphite furnace atomic absorption spectrometry (GF AAS) were developed. Accurate Hg determination in fish samples was possible after a solubilization in tetramethylammonium hydroxide and adding n-propanol, as low molecular organic compound, using PVG-GF AAS. The developed method for Se determination in coconut water with PVG-GF AAS have resulted in limits of detection and quantification of 0,65 μg L-1 and 2,2 μg L-1, respectively and that were similar with those obtained with CVG. The developed methods for Hg and Se determination in biological samples using PVG-GF AAS are sensitive, free of spectral interference, low-cost, and are a feasible alternative for CVG.
47

Estratégias analíticas para determinação sequencial de metais em vinhos por espectrometria de absorção atômica de alta resolução com fonte contínua por chama

Boschetti, Wiliam January 2012 (has links)
Neste trabalho foi desenvolvido e otimizado um método para determinação sequencial rápida por espectrometria de absorção atômica de alta resolução com fonte contínua por chama (HR-CS FS-FAAS) de metais em amostras de vinhos, produzidos em diferentes regiões do Brasil. As amostras foram obtidas de 8 regiões brasileiras diferentes: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. Os elementos avaliados foram: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb e Sr. Estes metais têm grande importância nas propriedades organolépticas do vinho, assim como para produção de uvas de qualidade. A validação do método foi feita pelo estabelecimento de curvas de calibração, realização de ensaios de recuperação e comparação dos resultados encontrados por HR-CS FS-FAAS com aqueles obtidos por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Padrões aquosos foram utilizados para a calibração e o coeficiente de correlação encontrado, para todos os analitos avaliados, foi maior que 0,9994. A partir das curvas de calibração os limites de detecção foram calculados para cada elemento: 44 μg L-1 para Cu, 5,0 μg L-1 para Li, 20 μg L-1 para Rb, 42 μg L-1 para Mn, 58 μg L-1 para Co, 15 μg L-1 para Sr, 23 μg L-1 para Be, 0,90 mg L-1 para Na, 4,4 mg L-1 para K e 0,92 mg L-1 para Ca. Ensaios de recuperação para cada analito foram realizados, encontrando recuperações entre 91 e 111%. A partir dos resultados encontrados, fazendo-se uso das técnicas de reconhecimento de padrões Análise por Componentes Principais (PCA) e Análise por Agrupamento Hierárquico (HCA) foi observada a formação de 7 grupos distintos, quando empregados os teores de K, Mn, Rb e Sr, dentre os 8 grupos (regiões do Brasil) avaliados. Com este conjunto de informações, portanto, é possível o monitoramento de fraudes e da qualidade do vinho produzido em cada região produtora. / In this work a method has been developed for the determination of metals in wine samples, produced in different regions of Brazil, using high-resolution continuum source fastsequential flame atomic absorption spectrometry (HR-CS FS-FAAS). The samples were obtained from eight different regions: Serra Gaúcha, Vale dos Vinhedos, Pinto Bandeira, Campos de Cima da Serra, Campanha Gaúcha, Serra Catarinense, Oeste do Paraná e Vale do São Francisco. The investigated elements were: Be, Ca, Co, Cu, K, Li, Mn, Na, Rb and Sr. These metals are important for the organoleptic properties of wine and for the production of grapes. The method was validated by recovery tests and comparison between the results obtained by HR-CS FS-FAAS and inductively coupled plasma optical emission spectrometry (ICP OES). Aqueous standards were used for calibration and the correlation coefficient found was higher than 0.9994 for all investigated elements. The detection limits were calculated from the calibration curves for each analyte: 44 μg L-1 for Cu, 5.0 μg L-1for Li, 20 μg L-1 for Rb, 42 μg L-1 for Mn, 58 μg L-1 for Co, 15 μg L-1 for Sr, 23 μg L-1 for Be, 0.90 mg L-1 for Na, 4.4 mg L-1 for K and 0.92 mg L-1 for Ca. The recovery tests showed results between 91 and 111%. After method validation the samples were evaluated. With the results obtained and using pattern recognition techniques Principal Component Analysis (PCA) and Hierarchical Cluster Analysis (HCA) was possible to find seven different groups, evaluating K, Mn, Rb and Sr concentration values, among the eight original groups (Brazilian regions) evaluated. Finally, using all the information obtained in this work, it’s possible to control frauds and the wine produced quality.
48

Determinação de elementos traço em carvão por espectrometria de absorção atômica de alta resolução com fonte contínua e por espectrometria de massa com plasma indutivamente acoplado e vaporização eletrotérmica

Borges, Daniel Lázaro Gallindo January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2013-07-15T23:13:45Z (GMT). No. of bitstreams: 1 228645.pdf: 621379 bytes, checksum: 233534c8262dbe43d103dbd7b1d98d58 (MD5) / Neste trabalho, o desenvolvimento de método para determinação de Cd e Pb por espectrometria de absorção atômica de alta resolução com fonte contínua com introdução direta da amostra sólida (SS-HR-CS AAS) e para determinação de As, Cd, Pb e Tl por espectrometria de massa com plasma indutivamente acoplado e vaporização eletrotérmica (ETV-ICP-MS) é demonstrado para a análise de amostras certificadas de referência de carvão. Para a amostragem direta de sólidos com análise por HR-CS AAS, as amostram foram moídas e inseridas em alíquotas de massa de 0,6 a 1 mg. Temperaturas de pirólise inferiores a 600 ºC geram fundo contínuo devido à eliminação incompleta da matriz e temperaturas elevadas de atomização propiciam o aparecimento de fundo estruturado. Após calibração contra padrões aquosos em HNO3 0,5% v/v, a determinação foi realizada com uso de Ir como modificador permanente para Cd e sem uso de modificador para Pb, resultando em boa concordância entre valores de referência e valores determinados. Para análise por ETV-ICP-MS, as suspensões (5 mg mL-1) foram preparadas em HNO3 5% v/v. Temperatura de pirólise e vaporização e a vazão dos gases interno e carreador foram otimizados. Ru foi adicionado em solução, agindo como modificador e como carreador do aerossol. Após calibração externa com padrões aquosos, bons resultados foram obtidos na análise dos materiais de referência.
49

Avaliação in vitro da difusão de íons Ca+2 e OH- de materiais endodônticos em dentes decíduos

Nunes, Ana Cristina Gerent Petry January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-21T03:14:01Z (GMT). No. of bitstreams: 1 200126.pdf: 1191399 bytes, checksum: 268151a00b86c4e8297b26e2267301ef (MD5) / O objetivo desta pesquisa foi avaliar a difusão de íons Ca+2 e OH- de materiais endodonticos através da raiz intacta de dentes decíduos. Todos os dentes foram instrumentados em seu comprimento de trabalho até a lima # 40, irrigados com solução de hipoclorito de sódio 1%, e secos com cones de papel absorvente. Os materiais utilizados como obturadores foram: pasta de Ca(OH)2 associada ao propilenoglicol espessada (CaPE); pasta UFSC, mistura de de pó de óxido de zinco com pó de Ca(OH)2 associado ao óleo de oliva; Vitapex ® e Sealapex ®. Após a obturação, todos os dentes tiveram o terço apical e coronal selados, e permaneceram em frascos individuais com solução fisiológica. A análise da difusão de íons OH- e Ca+2 foi realizada por meio de um pHmetro calibrado e um espectrômetro de absorção atômica, respectivamente em 48h, 7, 30, 45 e 60 dias. A pasta CaPE foi o material obturador que mais difundiu íons OH- e Ca+2.
50

Desenvolvimento de métodos para a determinação de mercúrio e tálio em amostras ambientais usando GF AAS e ETV-ICO-MS

Silva, Alessandra Furtado da January 2004 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-21T17:35:42Z (GMT). No. of bitstreams: 1 204136.pdf: 947494 bytes, checksum: 8d45a223926fb8b99323ef00e885e939 (MD5) / Métodos para a determinação de mercúrio e tálio em amostras ambientais por GF AAS e ETV-ICP-MS foram desenvolvidos, usando a análise direta de sólidos e suspensão. Foram investigados modificadores permanentes como irídio, paládio, ródio e rutênio para a determinação de mercúrio em materiais certificados: cinza, esgoto, sedimento marinho e sedimento de rio, usando a GF AAS com amostragem sólida. O desempenho do paládio foi o mais consistente, tendo a massa característica como o maior critério. Uma quantidade de mercúrio foi perdida da solução aquosa durante a etapa de secagem, e essa perda pode ser contornada após a adição de permanganato de potássio, que finalmente tornou possível o uso de calibração com padrões aquosos para a análise direta de sólidos. Os resultados obtidos para mercúrio foram satisfatórios para um procedimento de rotina, apresentando um limite de detecção de 0,2 mg kg-1. Foi proposto também um método para a determinação de mercúrio e tálio em amostras ambientais usando a ETV-ICP-MS com amostragem por suspensão. O permanganato de potássio em solução, bem como o potássio e o manganês em solução, foram estudados como modificadores e carreadores. A melhor sensibilidade e estabilização térmica foram obtidas com permanganato de potássio em um tubo não tratado, especialmente para tálio. A exatidão do método foi confirmada pela análise de oito materiais certificados, usando calibração externa com padrões aquosos preparados da mesma maneira que as suspensões. Os limites de detecção nas amostras foram 0,18 mg g-1 para Hg e 0,07 mg g-1 para tálio. A precisão encontrada para as diferentes amostras, como desvio padrão relativo, foi de 0,8-11 % para mercúrio e 1-9% para tálio (n = 3). O último desenvolvimento de método foi a determinação de tálio usando a GF AAS de alta resolução com fonte contínua. Os resultados obtidos sem modificador, com paládio adicionado em solução e rutênio como modificador permanente, para 11 amostras de carvão e uma de cinza de carvão foram concordantes, com um nível de confiança de 95%, usando calibração com padrões aquosos. A precisão, como desvio padrão relativo, foi melhor que 5% e o limite de detecção foi de 0,01 mg g-1 de tálio.

Page generated in 0.0544 seconds