• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 164
  • 37
  • 10
  • 10
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 582
  • 373
  • 306
  • 287
  • 265
  • 250
  • 63
  • 57
  • 46
  • 42
  • 39
  • 29
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
511

Pulsed Laser Injected Enhancement Cavity for Laser-electron Interaction / Cavités optiques en régime impulsionnel pour l'intéraction laser-électron

You, Yan 03 June 2014 (has links)
RésuméLa diffraction et la diffusion de rayons X sont utilisées dans de nombreux domaines de la physique, de la médecine et de la technologie. Des faisceaux de haute brillance sont néanmoins requis pour améliorer les performances de ces techniques. L’utilisation de la diffusion Compton d’un laser sur un faisceau d’électrons présente un grand intérêt pour la production de rayons X. Ce processus permet l’emploi d’un anneau de stockage d’électrons compacts et d’un résonateur optique pour accroître la puissance laser. Avec un tel système, un taux de collision laser-électron supérieur au méga Hertz est envisageable permettant d’atteindre un flux de rayons X de l’ordre de 10¹³ photons/s. Dans le premier chapitre, je décris les motivations pour le développement d’une source de rayons X basée sur la diffusion Compton et utilisant un résonateur optique. Je détermine aussi les performances que l’on peut attendre de ce type de sources ainsi que l’état de l’art actuel dans ce domaine. Dans le deuxième chapitre, je décris le comportement et les propriétés des résonateurs optiques en régime impulsionnel. J’introduis la notion de phase CEP (‘carrier envelope phase’) et je montre la nécessité de contrôler à la fois la fréquence de répétition de l’oscillateur laser et cette phase CEP. Le chapitre 3 est consacré aux oscillateurs fibrés à blocage de mode. Je montre les performances du laser que j’ai construit en utilisant le phénomène de rotation de polarisation non-linéaire.La méthode d’asservissement laser-résonateur optique ‘tilt locking’ est introduite au chapitre 4. Je décris tout d’abord les études de simulations et le montage expérimental qui ont permis de tester la méthode en régime impulsionnel. Je donne ensuite les résultats expérimentaux qui démontrent la faisabilité de la méthode ‘tilt locking’ en régime impulsionnel. J’effectue aussi une comparaison expérimentale des performances de la méthode ‘tilt locking’ avec la méthode classique ‘Pound-Drever-Hall’. Je termine le chapitre en indiquant une difficulté expérimentale de la méthode pour générer plusieurs signaux d’erreurs.Je décris la conception du système optique de la machine Compton TTX de l’université Tsinghua dans le chapitre 5. Les performances attendues pour cette machine sont des flux de rayons X compris entre 10¹º et 10¹³ photons/s. / X-ray diffraction and scattering, X-ray spectroscopy, and X-ray crystallography are widely used in the life sciences, material science, and medical diagnosis. High-quality and high-brightness X-rays are a strong requirement to improve applications. Inverse Compton scattering (ICS) X-ray source has attracted great interests worldwide lately. To significantly enhance the average X-ray photon flux, a compact electron storage-ring combined with a high finesse optical enhancement cavity (OEC) can be utilized. In such a system, the collision rate between the electron beam and the laser pulse is greatly increased to the MHz range, enabling a photon flux up to 10¹³ph/s.In the first chapter, I describe the motivation behind the development of OEC based on ICS X-ray source. The characteristics of this kind of X-ray source are summarized, compared to those of the conventional low-repetition-rate Terawatt laser system based on ICS X-ray source. The latest progress and research status of OEC based on ICS X-ray source are presented. Pulsed-laser injected high-finesse OEC stacking theory and properties are discussed in Chapter 2. Not only does the OEC based on ICS X-ray source require the laser pulse repetition rate to be matched to the free spectral range (FSR) of the cavity, where both also have to match the electron storage-ring circulation frequency. In addition, we have to match the phase shift of the laser repetition rate to the phase offset introduced by the dispersion of the cavity mirrors, since our cavity finesse design value is quite high. The stacking theory is analyzed in the frequency domain. Cavity properties, including cavity mirror dispersion, finesse, and FSR, are discussed in detail. A laser frequency comb and OEC coupling is analyzed also. The laser source development is presented in Chapter 3. We constructed a mode-locked fiber laser based on nonlinear polarization rotation. The locking model, locking techniques, and the theory, simulations and experimental tests of tilt locking (TL) in the pulsed laser injected high-finesse OEC are discussed in Chapter 4. We succeeded in locking a pulsed laser to a high-finesse cavity with the TL technique. The experimental results show that the TL and the Pound–Drever–Hall techniques have the same performance: stable locking, high sensitivity, and the same power coupling rate for picosecond laser pulse case, while the test results for full spectrum TL locking show that it is uneasy to align the split-photodiode to the beam waist.Based on the above experimental study and tests, we design the OEC system for Tsinghua University X-ray project in Chapter 5. The expected X-ray flux is 10¹º to 10¹³ ph/s. We detail every subsystem requirement.
512

Open Innovation Strategies : A new pivot for OEM and Start-up Coopetition

Sénécal, Julia, Jallow, Ismaila A. January 2019 (has links)
“[A]s much as any other product, the car has shaped not only the global economy but how billions of people live”1,whilethe digital area is nowshapingthe car.Coopetition, a strategy presenting firms with the opportunity to collaborate and compete at the same time,is becoming a prevalent phenomenonamong large OEMs and start-ups in the automotive industry.Respectively, considering that coopetition, in the context of open innovation and new technologies, has been identified as a successful strategy, this thesis will therefore analyse the relationship between OEMs and external start-ups in the context of coopetition and corporate open innovation strategies. Several typesof corporate incubators, accelerators and corporate innovation labs emerged within the last years, howeveran integration of all three of these has not yet been widely explored. Accordingly, while these open innovation streamsare used by large corporationsto get access to the start-upecosystemand increase their innovation capabilities, the relationship between OEMs and external start-ups will further lead to CIIAs (a combined approach of corporate incubators, corporate innovation labs and corporate accelerators),demonstratedin the context of coopetition. This exploratory study therebycontributes to the relationship between external start-ups and OEMsthrough aCIIA approach,answering the two following researchquestions;•What are the main drivers of the OEM and external start-uprelationship?•How do OEMs and external start-ups coopete in the context of corporate open innovation strategies?To dulyanswer these research questions, we choseaqualitative researchmethodcombined with an interpretivist and inductiveapproachas well asempirical findings generated from 6semi-structured interviews. We furthercontributed tothe illustrationof the key aspects of CIIAsas well asthe motives, management and implications behind the relationshipsbetween OEMs and external start-upsbyaconceptual framework. Our analysishence showsthe significanceof the access to complementary resources, the co-creation and co-development of value as well as the systematic implementation of a proof of conceptin the light of thesecoopetitive relationshipsbetween CIIAs and external start-ups.However, consideringthat thisresearch has been based on the German automotive industry only, it will require further research in other contexts, sectors or countries. To conclude, thisthesis contributes tothe management literature ofcoopetition, corporate innovation and entrepreneurship. We proposeda finalframeworkto highlightthekey motives, the management and the implications behind thecoopetitive relationshipsbetween OEMsand external start-upsthrough the CIIA platform.This willexpectedly help managers and entrepreneurs develop efficientmanagement techniques as well asfurther recognize and understand the influential dynamicspresent in these relationships
513

Étude de dipôles supraconducteurs en Nb3Sn à haut champ : isolation électrique à base de céramique et conception magnétique / Study of high field Nb3Sn superconducting dipoles : electrical insulation based made of ceramic and magnetic design

Rochepault, Etienne 04 October 2012 (has links)
Dans le contexte des améliorations du LHC, des efforts importants sont fournis pour concevoir des aimants d'accélérateurs utilisant l'alliage supraconducteur Nb3Sn, qui permet d'atteindre des champs magnétiques plus élevés (>12T). Le but de cette thèse est de proposer de nouvelles méthodes de calcul et de fabrication de dipôles à haut champ en Nb3Sn. Une isolation céramique, mise au point précédemment au CEA Saclay, a été testée pour la première fois sur des câbles, dans les conditions d’utilisation d’un aimant d’accélérateur. Des mesures de courant critique sous champ magnétique et contrainte mécanique ont notamment été réalisées. Ces campagnes d’essais ont révélé que l’isolation céramique actuelle est trop fragile mécaniquement et que les propriétés de courant critique sont dégradées. Une étude a ensuite été menée, afin d’améliorer la tenue mécanique de l’isolation et de mieux répartir les contraintes à l’intérieur du câble. Des méthodes de conception magnétique ont par ailleurs été proposées afin d’optimiser la forme des bobinages, tout en respectant des contraintes d’homogénéité de champ, de marges de fonctionnement, de minimisation des efforts… Pour cela plusieurs codes d’optimisation ont été élaborés. Ils se basent sur des méthodes nouvelles utilisant des formules analytiques. Un code 2D a d’abord été élaboré pour des conceptions en blocs rectangulaires. Ensuite, deux codes 3D ont été conçus pour l’optimisation des têtes de dipôles. Le premier consiste à modéliser le bobinage à l’aide de blocs élémentaires, et le deuxième se base sur une modélisation des câbles supraconducteurs par des rubans. Ces codes d’optimisation ont permis de proposer des configurations magnétiques pour des aimants à haut champ. / In the framework of LHC upgrades, significant efforts are provided to design accelerator magnets using the superconducting alloy Nb3Sn, which allows to reach higher magnetic fields (>12T). The aim of this thesis is to propose new computation and manufacturing methods for high field Nb3Sn dipoles. A ceramic insulation, previously designed at CEA Saclay, has been tested for the first time on cables, in an accelerator magnet environment. Critical current measures, under magnetic field and mechanical stress, have been carried out in particular. With this test campaign, the current ceramic insulation has been shown to be too weak mechanically and the critical current properties are degraded. Then a study has been conducted, with the objective to improve the mechanical strength of the insulation and better distribute the stress inside the cable. Methods of magnetic design have also been proposed, in order to optimize the coils shape, while fulfilling constraints of field homogeneity, operational margins, forces minimization… Consequently, several optimization codes have been set up. They are based on new methods using analytical formulas. A 2D code has first been written for block designs. Then two 3D codes have been realized for the optimization of dipole ends. The former consists in modeling the coil with elementary blocs and the latter is based on a modeling of the superconducting cables with ribbons. These optimization codes allowed to propose magnetic designs for high field accelerator magnets.
514

Estudo de viabilidade técnica econômica para implementação de uma unidade móvel para tratamento de efluentes industriais com feixe de elétrons / Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam

Rela, Carolina Sciamarelli 21 November 2006 (has links)
O tratamento de efluentes industriais é uma prática que vem se disseminando em ritmo acelerado, porque além de contribuir para reforçar a imagem pública, através do combate à poluição, ela traz vantagens econômicas para as empresas que podem reutilizar a água tratada do efluente em seus próprios processos. A técnica de tratamento estudada no presente trabalho é a que utiliza a oxidação/redução química destacando-se a utilização da radiação ionizante por meio de feixes de elétrons. Esta técnica utiliza um processo oxidativo avançado, gerando radicais altamente reativos que provocam a oxidação, redução, dissociação e degradação em compostos orgânicos e exercendo efeito letal nos microorganismos, protozoários e parasitas em geral. Neste trabalho desenvolveu-se um projeto conceituai e básico de uma unidade móvel de tratamento de efluentes utilizando radiação ionizante, fazendo com que a unidade se desloque até o ponto de tratamento, facilitando assim a logística. Em seguida, elaborou-se um estudo de viabilidade técnica e econômica permitindo dados consistentes sobre a capacidade e custo de processamento de efluentes e valores consolidados dos investimentos necessários para serem apresentados a órgãos financiadores para a construção de uma unidade móvel. Os resultados dos estudos demonstram que é viável tecnicamente a construção de uma unidade móvel, pois atende a legislação pertinente do Brasil, nos aspectos de Radioproteção e limite de transporte de carga. O custo unitário do processamento mostrou-se superior ao de uma unidade fixa em razão da diminuição da eficiência da interação da radiação incidente no efluente processado, devido à redução de energia do acelerador de elétrons e da disponibilidade de operação da unidade. / The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit.
515

Estudo de viabilidade técnica econômica para implementação de uma unidade móvel para tratamento de efluentes industriais com feixe de elétrons / Study of technical and economical feasibility for implementation of a movable unit for treatment of industrial effluents with electron beam

Carolina Sciamarelli Rela 21 November 2006 (has links)
O tratamento de efluentes industriais é uma prática que vem se disseminando em ritmo acelerado, porque além de contribuir para reforçar a imagem pública, através do combate à poluição, ela traz vantagens econômicas para as empresas que podem reutilizar a água tratada do efluente em seus próprios processos. A técnica de tratamento estudada no presente trabalho é a que utiliza a oxidação/redução química destacando-se a utilização da radiação ionizante por meio de feixes de elétrons. Esta técnica utiliza um processo oxidativo avançado, gerando radicais altamente reativos que provocam a oxidação, redução, dissociação e degradação em compostos orgânicos e exercendo efeito letal nos microorganismos, protozoários e parasitas em geral. Neste trabalho desenvolveu-se um projeto conceituai e básico de uma unidade móvel de tratamento de efluentes utilizando radiação ionizante, fazendo com que a unidade se desloque até o ponto de tratamento, facilitando assim a logística. Em seguida, elaborou-se um estudo de viabilidade técnica e econômica permitindo dados consistentes sobre a capacidade e custo de processamento de efluentes e valores consolidados dos investimentos necessários para serem apresentados a órgãos financiadores para a construção de uma unidade móvel. Os resultados dos estudos demonstram que é viável tecnicamente a construção de uma unidade móvel, pois atende a legislação pertinente do Brasil, nos aspectos de Radioproteção e limite de transporte de carga. O custo unitário do processamento mostrou-se superior ao de uma unidade fixa em razão da diminuição da eficiência da interação da radiação incidente no efluente processado, devido à redução de energia do acelerador de elétrons e da disponibilidade de operação da unidade. / The treatment of industrial effluents is a practice that is disseminating in accelerated rhythm, of contributing to reinforce the public image, through the combat of the pollution, it brings economical advantages allowing the companies the reuse of the treated water in their own processes. The liquid effluent treatment technique studied in the present work is the one that uses the chemical oxidation/reduction standing out the use of the electron beam (e.b.) radiation. This technique uses an advanced oxidation process, generating radicals highly reagents that provoke the oxidation, reduction, dissociation and degradation in composed organic and exercising lethal effect in general in the microorganisms and parasites. In this work a conceptual and basic project of a movable unit of effluents treatment using electron beam radiation process was developed, in order that the unit moves until the treatment point, where the effluent is produced, facilitating the logistics. A technical and economical feasibility study was also elaborated allowing data on the capacity and cost of effluents processing to consolidate the values of the necessary investments to be presented to foundations organs for the construction of a movable unit. The results of the studies demonstrated that it is technically viable attending the pertinent legislation of Brazil, in the aspects of Radiation Protection and transport limit capacity. The unitary cost of the e.b. radiation processing in the movable unit was shown more expensive than in the fixed unit, the reason is the decrease of the efficiency of the interaction of the incident electrons in the effluent, due to the reduction of electron energy operation time of the unit.
516

Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminas

Vieira, André Mozart de Miranda 19 February 2008 (has links)
Neste trabalho, as doses absorvidas produzidas em água pelo feixe de radiação de um Acelerador Linear Clínico - CLINAC 600C TM (Varian), com feixes de fótons de 6MV, foram avaliadas teórica e experimentalmente em configurações de campos quadrados, em seguida, em configurações de campos estreitos e circulares, obtidos com um colimador micro multi-lâminas - mMLC m3TM (BrainLab). A avaliação teórica foi feita por meio de cálculos com o Método de Monte Carlo. As curvas de porcentagem de dose profunda PDP e respectivas razões tecido máximo TMRs derivadas, do CLINAC 600C, medidas experimentalmente, foram validadas por meio de comparações com valores de referência, bem como com medidas usando diferentes detectores. Os resultados indicam diferenças menores que 5% pontualmente e em média menores que 1,5% para cada campo avaliado, quando comparados aos valores do comissionamento anterior (realizado no ano de 1999) e aos valores da literatura. Na comparação das medidas feitas com câmara de ionização e com diodo, a média das diferenças pontuais das curvas de PDP foi de -0,6% e as diferenças entre os perfis laterais de dose ficaram dentro de 1%, na região plana. O diodo fornece medidas de perfil com melhor resolução espacial. Os fatores relativos de dose dos campos abertos, atualizados, concordam com os valores de referência anteriores dentro de 1,03% de discrepância. As curvas de distribuição de dose absorvida em água, atualizadas, são, agora, consideradas de referência e permitem caracterizar o feixe desse CLINAC para o cálculo de dose em pacientes. Os espectros de fótons resultantes das simulações por Monte Carlo com os códigos PENELOPE e MCNP concordam em aproximadamente 80% dos pontos amostrados, sendo que as energias médias de (1,6 ± 0,3)MeV, com o MCNP, e de (1,72 ± 0,08)MeV, com o PENELOPE, são coincidentes. O modelo de fonte simples do CLINAC 600C, criado com o código PENELOPE, permite calcular as distribuições de dose em água, de campos abertos, com discrepâncias da ordem de ±1,0% na dose e de ±0,1 cm na posição, se comparados a medidas experimentais. Esses valores de discrepância atingem os critérios propostos inicialmente para validar o modelo de simulação e garantir sua aplicabilidade nas avaliações dosimétricas da Radioterapia desse CLINAC. A descrição geométrica do mMLC m3 para fins de simulação pelo Método de Monte Carlo, utilizando o código PENELOPE, foi considerada satisfatória ao permitir avaliar a transmissão desse colimador dentro de uma incerteza de ±0,2% e calcular uma subdosagem média de (11,4±2,0)%, devida ao efeito lingüeta-vão, que coincide com o valor determinado experimentalmente de (12,5±2,7)%, específicos para esse projeto de colimador. Os programas de simulação por Monte Carlo, que fazem o uso de um modelo de fonte simples do CLINAC 600C, combinado com o modelo completo do mMLC m3, permitiram calcular PDPs em água, de campos conformados, dentro do intervalo de ±1% de discrepância, enquanto que os fatores relativos de dose de campos conformados pelo mMLC puderam ser calculados com incertezas que variam de 1 a 3% concordando com os valores experimentais. Esses campos avaliados representam campos próximos àqueles usados nos tratamentos. Os resultados do trabalho garantem um conhecimento dosimétrico maior do colimador micro multi-lâminas m3, utilizado nas técnicas de radioterapia e radiocirurgia estereotáxica tridimensionais, e fornece uma ferramenta útil na avaliação das doses produzidas em configurações de campos complexas. / In this work, absorbed dose to water produced by the radiation beam of a clinical linear accelerator - CLINAC 600C TM (Varian), with a photon beam of 6 MV, were evaluated both theoretically and experimentally. This determination includes square and circular field configurations, the last one obtained with a micro multileaf collimator - mMLC m3TM (BrainLab). Theoretical evaluation was performed throughout Monte Carlo method. Experimental measurements of Percentage Depht Dose - PDD and derived Tissue Maximum Ratio - TMR curves from CLINAC 600C were validated by comparison with reference values as well as with measurements using different detectors. The results indicate local differences smaller than 5% and average differences smaller than 1,5% for each evaluated field, if they are compared to the previous commissioning values (made in 1999) and to the values of literature. Comparisons of ionization chamber and diode result in an average local difference of -0,6% for PDD measurements, and within 1% for lateral dose profiles, at depth, in the flat region. Diode provides measurements with better spatial resolution. Current output factors of open fields agree with reference values within 1,03% of discrepancy level. Current absorbed dose distributions in water are, now, considered reference values and allow characterization of this CLINAC for patient dose calculation. The photon spectra resulting from simulations with PENELOPE and MCNP codes agree approximately in 80% of the sampled points, in what average energies of (1,6 ± 0,3)MeV, with MCNP, and of (1,72 ± 0,08)MeV, with PENELOPE, are coincident. The created simple source model of the CLINAC 600C, using the PENELOPE code, allows one to calculate dose distributions in water, for open fields, with discrepancies of the order of ±1,0% in dose and of ±0,1cm in position, if they are compared to experimental measurements. These values met the initial proposed criteria to validate the simulation model and guarantee its applicability in dosimetric evaluations of radiotherapy with this CLINAC. The geometrical description of the mMLC m3 for Monte Carlo purposes, using the PENELOPE code, was considered satisfactory, providing the characterization of relevant physical parameters such as the transmission of the mMLC, within an estimated uncertainty of ±0,2%, and the average underdose of (11,4±2,0)%, due the tongue and groove effect, which is coincident with the experimental value of (12,5±2,7)%, for this particular collimator design. The Monte Carlo simulation codes which combine a single source model of the CLINAC 600C with the full m3 model, allows to calculate dose distributions in water for conformal beams within the discrepancy level of ±1%. However, output factors of conformal beams with the mMLC can be calculated with uncertainties varying from 1 to 3%, when they are compared to experimental results. These evaluated fields represent, and come close to treatment fields. The results of this work guarantee a better dosimetric knowledge of the micro multileaf collimator m3, which is used in three-dimensional stereotactic radiotherapy and radiosurgery techniques. This provides a useful tool in the evaluation of the mMLC as well as the absorbed doses produced in complex field configurations.
517

Implantação de um programa de controle de qualidade para sistemas de planejamento de tratamento computadorizados de acordo com o TRS 430 / Implementation of a quality assurance program for computerized treatment planning systems according to TRS 430

Camargo, Priscilla Roberta Tavares Leite 27 April 2006 (has links)
No presente trabalho serão apresentadas as diretrizes e os testes necessários para a implantação de um programa de controle de qualidade para o Eclipse 7.3.10 da Varian no Hospital das Clínicas da Faculdade de Medicina da USP, de acordo com a mais recente publicação da AIEA o TRS 430. Os testes recomendados pelo TRS 430 são basicamente divididos em testes de aceitação, comissionamento (testes dosimétricos e não dosimétricos), e testes rotineiros. O documento da AIEA está sendo implementado para o Eclipse no HC para os feixes de fótons de dois aceleradores lineares da Varian, Clinac 600C e Clinac 2100C. Os testes de aceitação verificaram parâmetros de \"hardware\"; integração do sistema \"network\"; transferência de dados, e \"softwares\". Os resultados obtidos mostraram boa concordância com as especificações do fabricante. Para os testes dosimétricos de comissionamento, foram realizadas medidas de dose absoluta para diversos arranjos experimentais. Esses valores foram comparados com os valores de dose gerados pelo SPTC. A grande maioria dos testes apresentou cerca de 90% a 80% dos pontos comparados, dentro dos níveis de tolerância, ou seja, uma boa concordância entre os valores experimentais e os valores gerados pelo SPTC. Somente arranjos de campos assimétricos apresentaram discordâncias grosseiras, mostrando a necessidade de uma investigação mais apurada para esses casos. Os testes de comissionamento não dosimétricos também apresentaram resultados excelentes, com praticamente todas as ferramentas e desempenho geral do sistema de acordo com as recomendações estipuladas no TRS 430. Foram aplicados também critérios de aceitabilidade para a comparação entre os valores de UMs gerados pelo sistema e os valores de UMs calculados manualmente. Os feixes no Eclipse foram caracterizados com dados transferidos do CadPlan e com dados provenientes do recomissionamento dos aceleradores, assim sendo, para esses testes encontrou- se uma diferença de até 3% para campos conformacionados para os dados de feixe provenientes do recomissionamento dos aceleradores, e de até 4% para os dados de feixe transferidos do CadPlan, sendo que o nível de tolerância estabelecido pelo TRS 430 para o arranjo era de 3%. / This work presents the guidelines and necessary tests tom implement a quality assurance program for Eclipse 7.3.10 from Varian at Hospital das Clinicas, Sao Paulo University School of Medicine - Brazil, in accordance with the new IAEA publication TRS 430. The recommended tests for the TRS 430 air mainly classified into acceptance tests, commissioning (dosimetric and non-dosimetric tests), and routine tests. The IAEA document\'s recommendations are being implemented at the hospital for two Varian linear accelerators - Clinac 600C e Clinac 2100C. The acceptance tests verified \'hardware\', integration of network systems, data transfer and \'software\' parameters. The results obtained are in a good agreement with the manufacturer\'s specifications. Measurements of absolute dose in several set-ups were made for the commissioning dosimetric tests. These data were compared to the absolute doses determined by the TPS. The great majority of the tests showed 90% to 80% of the analyzed data in acceptance levels, with a good agreement between the experimental data and the data determined by the TPS. Only settings with asymmetric fields presented significant discords, showing the need for a more detailed inquiry for these settings. The non-dosimetric commissioning tests have also presented excellent results, with virtually all the system tools and general performance in compliance with TRS 430. The acceptance criteria have been applied for a comparison between the values of MUs generated by TPS and the calculated manually ones. The beams have been characterized for Eclipse with data transferred from CadPlan and with data from recommissioning of accelerators, so for these tests it was found a difference of at least 3% for the conformal field shape for the data originated in the beams of recommissioning and at least 4% for the data proceeded from CadPlan. The tolerance level established by TRS 430 for this setting was 3%.
518

Intercomparação de colimadores de múltiplas lâminas para implementação de terapia de feixes de intensidade modulada / Multileaf collimator intercomparison for intensity modulated radiation therapy implementation

Viteri, Juan Fernando Delgado 10 January 2006 (has links)
Neste trabalho é apresentada uma intercomparaçào das características dosimétricas entre três sistemas de colimadores multi-lâminas: Varian Millenium com 120 lâminas, mMLC m3 Brainlab e Varian Mark II ambos com 52 lâminas. A largura da projeção das lâminas no isocentro e na região central do campo é de 0,5 cm; 0,35 cm e 1,0 cm respectivamente. Foram comparadas características dosimétricas comuns aos três sistemas em modo estático e, no modo dinâmico, o trabalho limitou-se aos dois primeiros. Em modo dinâmico, foram realizados testes que avaliam o funcionamento através da irradiação em filme de figuras padrão, como a reprodutibilidade e estabilidade do MLC. Foi testada a linearidade das UM, sensibilidade â interrupção de tratamentos, a constância na velocidade das lâminas encontrando-se em todos os casos dentro do ±3%. Na linearidade da taxa de dose existem diferenças quando este parâmetro diminui. Encontrou-se que o desvio médio da dose é inversamente proporcional à abertura média dos campos dinâmicos. O fator de rendimento em modo dinâmico apresentou variações de até 1% quando o sistema suporte funcional se encontrava em posições laterais. Para os três sistemas de MLC, nos perfis para um mesmo tamanho de campo foi observada uma inclinação maior na região de penumbra para o mMLC; nos fatores de rendimento existem também pequenas diferenças de um sistema para outro. A abertura dosi métrica entre pares de lâminas foi determinado para o MLC 120, mMLC e MLC 52, os valores obtidos para 6 MV foram: (0,202 ± 0,054) cm; (0,157 ± 0,070) cm e (0,189 ± 0,081) cm respectivamente. A transmissão apresentou um comportamento crescente com a profundidade e o tamanho de campo para 6 MV nos três sistemas. Os valores médios determinados com câmara de ionização para 6 MV foram os seguintes: (1,630 ± 0,018)% para o MLC 120; (1,291 ± 0,029)% para o mMLC e (1,638 ± 0,010)% para o MLC 52. Quando testada com filme, a transmissão entre as lâminas e intralâminas apresentou dependência com a posição fora do eixo central tanto no MLC 120 quanto no mMLC. A porcentagem de espalhamento produzido pelo MLC, com relação a um campo aberto de referência de 6 MV foi: (0,297 ± 0,024)% para o MLC 120; (0,239 ± 0,052)% para o mMLC e (0,202 ± 0,028)% para o MLC 52. A penumbra (80-20%) em função do deslocamento fora do eixo não apresentou variações significativas nos três sistemas. Para todos os MLCs, a penumbra apresentou um comportamento crescente em função do tamanho de campo definido pelas lâminas. Em função da profundidade em 6 MV, a penumbra apresentou o menor valor para o mMLC em d max: 2,59 mm e o maior é 6,74 mm para o MLC Mark II a 10 cm de profundidade. A penumbra em função do ângulo que as lâminas formam com o seu eixo de movimento, para o ângulo de 10° no mMLC apresentou um valor 3,74 mm; já para os ângulos maiores, os maiores valores foram os obtidos para o Mark II. A série de testes descrita no presente trabalho permite estabelecer uma rotina no comissionamento de sistemas de MLC que pode ser aplicada nos serviços de Radioterapia que vão comissionar sistemas de MLC para IMRT em modo dinâmico. Os resultados descritos permitem caracterizar cada um dos sistemas de MLC estudados. Não é possível dizer que um sistema é melhor que outro, mas é possível, a partir da escolha de um deles, identificar as possíveis vantagens e desvantagens que cada um vai apresentar. / In this work a dosimetric comparison between three multileaf collimator systems is presented: a Varian Millennium with 120 leaves, Brainlab mMLC m3 and Varian Mark II both with 52 leaves. The width projection at isocenter level in field\'s central region are: 0,5 cm; 0,35 cm and 1,0 cm respectively. Common dosimetric characteristics for the three systems in static mode and dynamic capabilities for the two first were compared. In dynamic mode, tests validating proper MLC function through film irradiation were done, such MLC stability, MU linearity, treatment interruptions sensitivity, stability of MLC in dynamic mode, leaf speed stability, were found within ±3% deviation in all cases. Dose rate linearity showed differences when this parameter decreases in dynamic mode. Average dose errors for fixed width gaps moving at constant speed were found to be proportional to gap errors and inversely proportional to the gap width. Output factors differences delivered through a sweeping gap were found less than ±1% when the gantry was in a lateral position. For the three MLC systems, when comparing beam profiles for the same field was observed that for mMLC presents the sharpest dose gradient region. In the output factors small differences where observed in every MLC system. Dosimetric leaf gap was determined for MLC 120, mMLC and MLC 52, obtained values for a 6 MV beam are: (0,202 ± 0,054) cm; (0,157 ± 0,070) cm and (0,189 ± 0,081) cm respectively. The transmission showed an increase with depth and field width for 6 MV in all the three systems. Average values obtained with ionization chamber for this energy were: (1,630 ± 0,018)% for MLC 120; (1,291 ± 0,029)% for mMLC and (1,638 ± 0,010)% for MLC 52. When obtained through film irradiation, inter and intra leaf transmission showed an off axis dependent behavior for MLC 120 and mMLC. Scatter produced by MLC as a 6 MV open reference field ratio was: (0,297 ± 0,024)% for MLC 120; (0,239 ± 0,052)% for mMLC and (0,202 ± 0,028)% for MLC 52. It was verified that penumbra width (80-20%) as a function of off axis leaf position do not showed significant differences in all systems. As a function of field width defined by MLC leaves, penumbra width presented an increasing behavior. When tests as a depth function in a 6 MV field, penumbra showed the smallest value for the mMLC at dmax: 2,59 mm and the biggest was 6,74 mm for the MLC Mark II AT 10 cm depth. Penumbra dependence with leaf movement axis showed that for 10 deg, the mMLC presented a 3,74 mm value, for larger angles, the higher values were obtained for MLC Mark 11. Described series of tests described in the present investigation allows to establish a commissioning routine for MLC systems, that could be applied in a Radiotherapy Department that will commission those systems for dynamic IMRT. Obtained results allow to characterize every MLC studied system. It is not possible to establish which system is better, but when one is chosen it is feasible to identify vantages and disadvantages that everyone will present.
519

Evitando Mission drift: o papel das aceleradoras na manutenção da lógica híbrida dos negócios de impacto social

Azeredo, Elisângela Marlize Dalpiaz de 27 March 2018 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-08-06T14:45:05Z No. of bitstreams: 1 Elisângela Marlize Dalpiaz de Azeredo_.pdf: 1506700 bytes, checksum: 0a85bcb1bedded10aaf79f106d4afee8 (MD5) / Made available in DSpace on 2018-08-06T14:45:05Z (GMT). No. of bitstreams: 1 Elisângela Marlize Dalpiaz de Azeredo_.pdf: 1506700 bytes, checksum: 0a85bcb1bedded10aaf79f106d4afee8 (MD5) Previous issue date: 2018-03-27 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O interesse pelos negócios de impacto social vem crescendo nas últimas décadas, tendo em vista que estes negócios representam uma fonte promissora de geração de valor social, econômico e financeiro. Entretanto, ao aliarem criação de valor social e sustentabilidade financeira, combinam elementos provenientes de lógicas institucionais diferentes, podendo enfrentar desafios inerentes a esta junção. Desta forma, a fim de que estes negócios obtenham êxito, faz-se necessário o desenvolvimento de um ecossistema de suporte robusto. Dentre os atores do ecossistema, destacam-se as aceleradoras, que visam apoiar o crescimento destes negócios, na fase inicial ou de expansão, exercendo, desta forma, um papel importante na construção e desenvolvimento das lógicas institucionais nestes negócios. Por consequência, influenciam a forma pela qual evitam mission drift, fenômeno que consiste no distanciamento do negócio da sua missão social. Sendo assim, o objetivo deste estudo é analisar as estratégias utilizadas pelas aceleradoras para assegurar e monitorar que os negócios de impacto mantenham a lógica híbrida, alcançando o equilíbrio entre a criação de valor social e a sustentabilidade financeira, evitando mission drift. A fim de atingir o objetivo proposto, foi realizado um estudo de caso múltiplo, com quatro aceleradoras, que atuam com negócios de impacto social. Por meio da compreensão do papel que exercem na manutenção da lógica híbrida dos negócios impulsionados por elas, identificaram-se as fontes de mission drift, bem como as estratégias para evitar o fenômeno durante o programa de aceleração, contribuindo, desta forma, com o campo teórico e gerencial. As implicações teóricas do estudo consistem na identificação da influência que as aceleradoras exercem nos negócios de impacto impulsionados por elas, por meio das estratégias utilizadas para assegurar a manutenção da lógica híbrida, contribuindo tanto para o estudo das lógicas institucionais quanto do fenômeno mission drift. No que tange às contribuições gerenciais, fornece um conjunto de estratégias a serem utilizadas pelas aceleradoras, a fim de assegurar e monitorar a manutenção do equilíbrio entre a criação de valor social e a sustentabilidade financeira nos negócios que aceleram. / The interest by the social enterprises has been growing in recent decades, considering that these organizations represent a promising source for generating social, economic and financial value. However, as they ally social value creation and financial sustainability, they combine elements from different institutional logics and may face challenges inherent to this combination. In this way, in order that these organizations achieve success, it is necessary to develop a robust support ecosystem. Among the actors of the ecosystem, the accelerators stand out. They aim to support the growth of social enterprises at an early stage or an expansion stage, exercising, in this way, an important role in the construction and development of institutional logics in these organizations. Consequently, they influence the way in which them avoid mission drift, a phenomenon that consists in the detachment of a business from its social mission. Therefore, the objective of this study is to analyze the strategies used by the accelerators to ensure and to monitor that the social enterprises maintain the hybrid logic, achieving the balance between the creation of social value and financial sustainability, avoiding mission drift. In order to achieve the proposed objective, it was conducted a multiple case study, with four accelerators, working with social enterprises. The sources of mission drift, as well as the strategies to avoid the phenomenon during the acceleration were identified through the understanding of the role that the accelerators exercise in maintaining the hybrid business logic in the business fueled by them, contributing, in this way, with the theoretical and managerial field. The theoretical implications of the study consist in the identification of the influence that the accelerators exert over the social enterprises boosted by them, through the strategies used to ensure the maintenance of the hybrid logic, contributing to the study of institutional logics as well as to the phenomenon of mission drift. Regarding the managerial contributions, the study provides a set of strategies to be used by the accelerators, in order to ensure and monitor the maintenance of the balance between the creation of social value and the financial sustainability in the business accelerated by them.
520

Eletronterapia intraoperatória adjuvante  no carcinoma inicial invasivo de mama: tolerabilidade, satisfação estética e eficiência terapêutica / Adjuvant intraoperative electron-beam therapy for early invasive breast carcinoma: toxicity, therapeutic efficacy and aesthetic satisfaction

Hanna, Samir Abdallah 31 January 2014 (has links)
INTRODUÇÃO: A razão para a radioterapia parcial da mama em comparação ao tratamento convencional da mama inteira baseia-se em 3 pontos: a) cerca de 90% das recidivas locais ocorre na adjacência do tumor primário; b) é possível estabelecer a equivalência de efetividade entre a dose única e o tratamento fracionado convencional; e c) existem dificuldades logísticas, financeiras e emocionais no tratamento fracionado convencional (falta da disponibilidade do aparelho de radioterapia em muitos municípios e desistência de tratamento das mulheres que iniciam a radioterapia convencional). Em maio de 2004 iniciou-se um estudo prospectivo com a eletronterapia intraoperatória adjuvante no carcinoma inicial invasor de mama, porém com sistemática de tratamento diferente de outras técnicas: ao invés de se usar um acelerador linear portátil e dedicado, utilizou-se o acelerador linear estático convencional. Neste trabalho, buscou-se analisar a frequência de complicações imediatas e tardias; o grau de satisfação estética das pacientes com as mamas após o tratamento; e as taxas de sobrevida livre de doença e sobrevida livre de falha local. MÉTODOS: Coletaram-se dados dos prontuários, buscando informações demográficas, do estadiamento inicial, da avaliação histopatológica intraoperatória (margens cirúrgicas e linfonodo sentinela), dados técnicos da eletronterapia e os achados finais em exame de parafina. Além disso, a frequência de complicações imediatas (até um mês de cirurgia) e tardias (depois de um mês), a estética (um ano da cirurgia, usando a escala de Harvard/NSABP/RTOG) e finalmente os índices de sobrevida global e livre de evento. RESULTADOS: Foram incluídas 169 pacientes e destas 35 foram excluídas devido a critérios intraoperatórios (linfonodo sentinela positivo ou margens positivas). Assim, 134 foram analisadas com idade mediana de 57,9 (40-85,4) anos, em um seguimento mediano de 50,6 (1-97,2) meses. Quatro pacientes desenvolveram recidiva local e três tiveram recorrência regional. As estimativas actuariais em 5 anos de sobrevida global, livre de eventos e livre de falha local foram respectivamente 97, 90,5 e 93,6%. A incidência cumulativa de falha local em 5 anos foi de 3,7%. A incidência global de toxicidade aguda foi de 8,2% e tardia de 26,2%. Os resultados estéticos excelentes, bons, regulares e ruins observados foram respectivamente 70,9%, 14,2%, 3,7% e 3,0%. Os tamanhos de colimador utilizados foram 4 cm em 18,7%, 5 cm em 80,6% e 7 cm de 0,7% dos casos. A energia de elétrons escolhida para tratamento foi de 6 MeV em 7,4%, 9 MeV em 52,2%, 12 MeV em 35,8%, 15 MeV em 3,7%, e 18 MeV em 0,7%. Os aceleradores lineares dedicados apresentam opção de energia de elétron variando até 9 MeV. Sendo assim, 40,29% dessa amostra provavelmente seria sub-tratada em equipamentos dedicados, pois foram necessários valores maiores de energia de elétrons para um tratamento adequado. Todas as pacientes fizeram portal-filme para checagem antes do tratamento e em 72,4% o alinhamento entre o disco de proteção e o colimador foi suficiente. No entanto, 27,6% das pacientes tiveram que ter os discos reposicionados. Nenhum caso de infecção no período perihospitalar fora observado. CONCLUSÕES: A eletronterapia intraoperatória com acelerador linear convencional apresentou baixa frequência de complicações e resultados estéticos desfavoráveis, e foi oncologicamente efetiva / INTRODUCTION: The rationale for partial breast radiation therapy when compared to conventional whole breast treatment is based on three points: a) about 90% of local recurrences occur in the adjacent area of the primary tumor, b) it is possible to establish equivalence between the effectiveness of single dose and fractionated conventional treatment, and c) there are logistical, financial and emotional difficulties related to conventional fractionated treatment (lack of availability of radiotherapy facilities in many cities and the high dropout rate of women who start conventional radiotherapy). In May 2004 we started a prospective trial using adjuvant intraoperative electron-beam therapy in early invasive breast cancer, but instead of a dedicated linear accelerator, we used the static conventional linear accelerator. In this study, we aimed to analyze the frequency of early and late complications, the cosmetic satisfaction of patients after treatment, and freedom from disease and local recurrence rates. METHODS: Data were collected from medical records, looking for demographic information, the initial stage, intraoperative and definitive histopathological evaluation of surgical margins and sentinel lymph node, technical data and pathologic staging, and follow-up data. In addition, the frequency of immediate (up to one month of surgery) and late (after one month) complications, aesthetics (one year of surgery, using the scale of Harvard/NSABP/RTOG), and finally the event-free and overal survival were obtained. RESULTS: We included 169 patients and 35 of these were excluded due to intraoperative criteria (positive sentinel lymph nodes or margins). Thus, 134 were analyzed. The median age was 57.9 (40 to 85.4) years and the median follow-up was 50.6 (1 to 97.2) months. Four patients developed local recurrence and three had regional recurrence. The actuarial estimates for overall, event-free, and local failure-free survivals were respectively 97, 90.5, and 93.6%. The crude incidence of local failure at 5 years was 3.7%. The overall incidences of acute and late toxicities were respectively 8.2% and 26.2%. The cosmetic results as excellent, good, fair and bad respectively were observed in 70.9%, 14.2%, 3.7% and 3.0%. Collimator sizes were 4 cm in 18.7%, 5 cm in 80.6%, and 7 cm in 0.7% of cases. The electron energy chosen for treatment was 6 MeV in 7.4%, 9 MeV in 52.2%, 12 MeV in 35.8%, 15 MeV in 3.7% and 18 MeV in 0.7%. The dedicated linear accelerators have electron beam energy ranging up to 9 MeV. Thus, 40.29% of these patients probably would not be treated adequately in dedicated equipment due to the need for higher values of electron energy. All patients underwent portal-film and in 72.4% the alignment between the shielding disc and the collimator was enough. However, in 27.6% of patients it had to be repositioned. No case of infection was observed during perihospitalar time. CONCLUSIONS: Intraoperative electrontherapy using conventional linear accelerator has shown low complications and worsening aesthetics rates, and oncologic efficacy

Page generated in 0.0699 seconds