• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 152
  • 50
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 211
  • 211
  • 146
  • 104
  • 64
  • 63
  • 57
  • 42
  • 41
  • 26
  • 25
  • 25
  • 25
  • 24
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação in vitro da biocompatibilidade de resinas acrílicas para base de próteses e materiais reembasadores resilientes

Chaves, Carolina de Andrade Lima [UNESP] 24 July 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-24Bitstream added on 2014-08-13T18:01:13Z : No. of bitstreams: 1 000734605.pdf: 2209864 bytes, checksum: acb17f8f0ad0805c7336b7a12bf4ea7d (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade de 3 resinas acrílicas (RA) para bases de prótese sendo duas polimerizadas por energia de microondas (Vipi Wave-VW e Nature Cryl-NC) e uma fotoativada (Eclipse-E); e a biocompatibilidade de materiais reembasadores resilientes (MRR), sendo 2 à base de silicone (Ufi Gel P e Sofreliner S), 2 à base de resina acrílica (Durabase Soft e Trusoft) e 2 condicionadores de tecidos (Softone e Coe Comfort) por meio de análises do metabolismo celular, da morfologia celular, do padrão de morte celular, da proliferação celular e da expressão do fator de crescimento TGFß 1, da integrina α5ß1 e de citocinas. A análise das RA foi realizada com células L929; para os MRR, as análises foram realizadas utilizando-se células L929, e/ou HaCaT e/ou RAW 264,7. Os resultados obtidos foram submetidos à análise estatística, realizada ao nível de significância de 5%. Todos os materiais quando testados com eluatos não apresentaram efeitos citotóxicos, e quando testados em contato direto (MTT e azul de alamar) alteraram significativamente a viabilidade celular, tendo sido os menores valores observados para o material NC quando comparado ao E. Para os materiais reembasadores o T, S e C. Maior taxa de necrose e apoptose foram observadas para os eluatos de todos os materiais quando avaliados no período de 24 horas; além disso, foi demonstrado que os materiais avaliados podem desencadear a expressão do TGFß 1, da integrina α5ß1 e de proteínas inflamatórias (fator de necrose tumoral - TNF-α, da citocina IL-1ß e de 5 quimiocinas: CCL2, CCL3, CCL5, CXCL2 e CXCL4). Sendo assim, de acordo com as limitações do presente estudo, pode-se concluir que a resina Nature Cryl resultou em menor viabilidade celular que a resina Eclipse e que os materiais Ufi Gel P e Sofreliner S apresentaram, em geral, melhor bicompatibilidade dentre os materiais reembasadores resilientes avaliados. / The aim of this study was to evaluate the cytotoxicity of 3 denture base acrylic resins with different polymerization methods (Eclipse, Vipi Wave and Nature Cryl) and the biocompatibility of soft lining materials, 2 silicone-based (Ufi Gel P and Sofreliner S), 2 acrylic-based (Durabase Soft and Trusoft) and 2 tissue conditioners (Softone and Coe Comfort), by analysing cell metabolism, cell morphology, pattern of cell death, cell proliferation and expression of growth factor TGFß 1, integrin α5ß1 and cytokines. For the acrylic resins, analyses were made with L929 cells, while for the resilient lining materials, analyzes were performed using L929, and/or HaCaT and/or RAW 264.7 cells. Results were statistically analyzed, at a significance level of 5%. The 24 and 48-h eluates from all materials were not cytotoxic to the cells. For the direct contact tests (MTT and Alamar Blue), a significant effect on cell viability was found, with the lowest values observed for materials NC when compared with E and between the reliners Trusoft, Softone and Coe Comfort. For all materials, increased rate of necrosis and apoptosis were observed for the 24 hs eluates. It was also demonstrated that all materials tested can trigger the expression of TGFß 1, α5ß1 integrin and inflammatory proteins (tumor necrosis factor -TNF-α, cytokine IL-1ß and 5 chemokines- CCL2, CCL3, CCL5, CXCL2 and CXCL4). Thus, within the limitations of this study, it can be concluded that the denture base acrylic resin Nature Cryl resulted in lower cell viability compared to the Eclipse resin and that the materials Ufi Gel P and Sofreliner S showed better biocompatibility among the soft liner materials evaluated.
62

Avaliação da influência do método de polimerização e da espessura da base de próteses totais na porosidade da resina acrílica

Pero, Ana Carolina [UNESP] [UNESP] 17 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-17Bitstream added on 2014-06-13T20:58:46Z : No. of bitstreams: 1 pero_ac_me_arafo.pdf: 475502 bytes, checksum: 7962f5d801f2cc928c6960616073f175 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente trabalho foi avaliar a porosidade em bases de resina acrílica de prótese total maxilar, processadas em diferentes ciclos de polimerização e confeccionadas em três espessuras (2,0, 3,5 e 5,0 mm). Cinco grupos foram estabelecidos, de acordo com os ciclos de polimerização: A) Onda-Cryl, ciclo curto em microondas; B) Onda-Cryl, ciclo longo em microondas; C) Onda-Cryl, ciclo do fabricante; T) Clássico, banho de água; Q) Jet, ciclo em câmara de pressão. Após o seu processamento, as bases de resina acrílica foram pesadas em ar e em água e a porcentagem de porosidade foi relacionada com a absorção de água no interior desse material. Os dados de % de porosidade foram submetidos ao teste de Kruskal-Wallis para a comparação entre os grupos (a= 5%). Dentro das limitações do presente estudo, concluiu-se que os ciclos de polimerização e a espessura do espécime de resina acrílica têm influência na porosidade, já que diferenças estatisticamente significantes foram encontradas entre os ciclos e espessuras avaliados. Não houve diferença de porosidade entre as bases de resina polimerizadas no ciclo T para qualquer uma das espessuras. / The aim of this study was to evaluate the porosity on (acrylic resin) maxilar complete denture bases, processed through diferent polimerization cycles, procedure done in three different kinds of thickness (2,0, 3,5 e 5,0 mm). Five groups were proposed, according to the polimerization cycles: A) Onda-Cryl, short microwave cycle; B) Onda-Cryl, long microwave cycle; C) Onda-Cryl, manufacturing microwave cycle; T) Clássico, water bath; Q) Jet, press chamber cycle. After the process, the denture bases were weighted in air and in water, and the percent of porosity was related to the water absorption within this material. The porosityþs % data were submitted to the Kruskal-Wallis test to promote the comparison among the groups. In despite of the present paperþs limitations, we have concluded that the polimerization cycles and the specimenþs thickness of acrylic resin really influence the porosity. This result was reached because statistically significant differences were found in the cycles and thickness evaluated. It has been not observed porosity differences in the polimerized resin bases in T cycle in relation to any thickness.
63

Efeito de diferentes tratamentos térmicos sobre o conteúdo de monômero residual de resinas acrílicas para reembasamento

Urban, Vanessa Migliorini [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T19:16:53Z : No. of bitstreams: 1 urban_vm_me_arafo.pdf: 1219036 bytes, checksum: 4e3be4eb79ce75a36f6d11fd248eff4f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi estabelecer, inicialmente, um método analítico em CLAE, para comparar o conteúdo de monômero residual de uma resina autopolimerizável para reembasamento imediato (Duraliner II - D) e uma resina termopolimerizável utilizada na confecção de bases de próteses (Lucitone 550 - L). Além disso, foi avaliado o efeito de dois tratamentos térmicos sobre esse conteúdo. Os monômeros utilizados como padrões foram o MMA (resina L) e o BMA (resina D). As condições cromatográficas para a análise foram: coluna ODS (15,0 x 0,46 cm), com 5 mm de tamanho de partícular e 100 Å de tamanho de poro, fase móvel ACN : H2O (55%: 45%) + 0,01% TEA, fluxo 0,8 mL/min, l 230 nm, volume de injeção 100 mL. As resinas foram proporcionadas e polimerizadas de acordo com as instruções dos fabricantes. Os corpos-de-prova (n = 18) dos dois materiais foram divididos em 3 grupos, com 6 corpos-de-prova cada. O grupo I (GI) não foi submetido a nenhum tratamento (controle). Para o grupo II (GII), os corpos-de-prova foram irradiados com microondas, a 550 W por 3 min para o material L e a 650 W por 4 min para o material D. Para o grupo III (GIII), os corpos-de-prova dos materiais L e D foram submetidos ao tratamento térmico por imersão em água a 55oC por 60 min e 10 min, respectivamente. Cada corpo-de-prova foi, então, fragmentado e submetido ao procedimento de extração em MeOH por 2 horas. Os valores de conteúdo de monômero residual foram transformados em porcentagem e analisados pelo teste de Kruskall-Wallis, ao nível de confiança de 99%. Em todos os grupos avaliados, o material D apresentou valores médios de monômero residual (GI - 0,87%; GII - 0,71%; GIII - 0,52%) significativamente maiores (p<0,01) que o material L (GI - 0,09%; GII - 0,06%; GIII - 0,05%). De acordo com a metodologia utilizada neste estudo, foram obtidas as seguintes conclusões: 1) O método... / The aim of this study was to firstly establish an analytical method, which was the most satisfactory with reference to optimization of chromatographic conditions for HPLC. The method was then used to compare the residual monomer content in one hard chair-side reline resin (Duraliner II - D) and one heat-polymerized denture base resin (Lucitone 550 - L). Also, it was investigated the effect of two after polymerization heat-treatments on this residual monomer content. The HPLC operating conditions established were column ODS (15.0 x 0.46 cm), with 5 mm particles, mobile phase - 55% ACN : 45% deionized distilled water, flow injection rate - 0.8 mL/min., wave length detection - UV 230 nm, amount of sample solution injection 100 mL. Calibration curves were produced using standard solutions containing known amounts of each monomer evaluated (MMA - L; BMA - D) in mobile phase. The materials (D and L) were mixed and polymerized according to the manufacturer's instructions. Specimens (n = 18) of both materials were then divided into three groups, of six specimens each. Group I specimens were left untreated (GI - control). Specimens of group II (GII) were given heat treatment by microwave irradiation with 550 W for 3 min for material L and 650 W for 4 min for material D. For group III (GIII), L and D specimens were submitted to a heat-treatment by immersion in water at 55oC for 60 min and 10 min, respectively. Each specimen were cut into small pieces and subjected to an extraction procedure in methanol for 2 hours. The residual monomer content was then expressed as a percentage of residual monomer in the specimen. The percentage residual monomer data were analyzed by non-parametric Kruskall-Wallis test, at 99% level of confidence. In all groups evaluated, material D showed significantly higher (p<0.01) residual monomer mean values (GI - 0.87%; GII - 0.71%; ...(Complete abstract, click electronic access below)
64

Efeito da complementação térmica de polimerização sobre a resistência flexural e dureza de resinas acrílicas para reembasamento

Seó, Rosangela Seiko [UNESP] 25 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-25Bitstream added on 2014-06-13T19:58:18Z : No. of bitstreams: 1 seo_rs_me_arafo.pdf: 703350 bytes, checksum: 5c30291cb31b160b0c3ae925308ad49c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O procedimento de reembasamento da prótese é normalmente utilizado para restabelecer a adaptação entre a prótese e o tecido bucal. As resinas autopolimerizáveis são um dos materiais indicados para o reembasamento. No entanto, tem sido demonstrado que, após a polimerização das resinas autopolimerizáveis, nem todo o monômero é convertido em polímero e esse monômero residual pode afetar as propriedades mecânicas desses materiais. Estudos têm sugerido que o conteúdo de monômero residual pode ser reduzido pela irradiação em microondas ou tratamento em banho de água. Esse estudo avaliou o efeito dos tratamentos térmicos sobre a resistência à flexão e dureza Vickers de quatro resinas autopolimerizáveis para reembasamento (Duraliner II - D, Kooliner-K, Tokuso Rebase Fast - TR e Ufi Gel Hard - UGH) e uma resina termopolimerizável (Lucitone 550 - L). Para cada material, trinta corpos-de-prova foram confeccionados e igualmente divididos em três grupos. No grupo controle, os corpos-de-prova foram submetidos ao teste de resistência à flexão imediatamente após sua polimerização. Previamente ao teste, os grupos 2 e 3 foram submetidos ao tratamentos complementares em banho de água e irradiação por microondas, respectivamente. Os corpos-de-prova do material para base de prótese foram armazenados em água por 48 horas a 37o l 1oC previamente ao teste. As medidas de força foram realizadas em máquina de ensaio universal MTS 810 com uma velocidade de 5 mm/min, utilizando o teste em três pontos a uma distância de 50 mm entre os apoios. Em seguida, um dos fragmentos do corpo-de-prova foi submetido ao teste de dureza Vickers. Os valores de dureza foram determinados utilizando-se uma carga de 25 gf (resinas K, TR, L e UGH) e 10 gf para a resina D, após 30 segundos de contato. Doze mensurações de dureza foram realizadas em cada corpo-de-prova e... / To maintain the prosthesis-tissue relationship, denture base reline procedure is commonly required. Autopolymerizing resins are one of the materials indicated for relining. It has been shown that, after polymerization, not all the monomer is converted to polymer in autopolymerizing resins and this residual monomer could detrimentally affect the mechanical properties of the materials. It has been suggested that the residual monomer could be decreased by microwave irradiation or water bath heat-treatments. This study investigated the effect of heat treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II - D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and one heat-polymerized resin (Lucitone 550-L). For each material, 30 specimens were made and equally divided into three groups. In control group, the specimens were submitted to the flexural strength test immediately after polymerization. Before testing, groups 2 and 3 were submitted to water bath and microwave post-cure treatments, respectively. The denture base material specimens were stored in water for 48 h at 37o l 1oC before they were bend-tested. Force measurements were made with a testing machine MTS 810 at a crosshead speed of 5 mm/min using a three-point bending fixture with a span of 50 mm. Thereafter, one fragment of specimen was submitted to Vickers microhardness test. The values were determined by using a 25 gf load (resins K, TR, UGH and L) and 10 gf for resin D, after 30 s contact. Twelve hardness measurements were taken on each specimen and the average was then calculated. Kruskal-Wallis non-parametric test was used for determination of statistical significance (p<0.01). The results demonstrated that: compared to the control groups, the flexural strength of TR and...(Complete abstract, click electronic access below)
65

Análise da estabilidade de cor de botões de íris artificiais obtidos por diferentes técnicas e após o envelhecimento acelerado

Bannwart, Lisiane Cristina [UNESP] 23 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-04-23Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1 000737733.pdf: 1813264 bytes, checksum: 5276c6bddbc491cf01ada48860d5d3d6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. As técnicas existentes para a confecção da prótese ocular devem resultar em íris artificiais perfeitamente estéticas com conseqüente dissimulação do defeito facial. Dessa forma, este estudo tem como propósito verificar a alteração de cor do botão de íris artificial entre diferentes técnicas após a polimerização e o envelhecimento acelerado. Foram confeccionadas 60 amostras simulando próteses oculares distribuídas em grupos (n=10) de acordo com a técnica utilizada, sendo: PE: técnica convencional sem verniz, PEV: técnica convencional com verniz, CA: técnica com calota pré-fabricada sem verniz, CAV: técnica com calota pré-fabricada com verniz, PI: técnica da pintura invertida sem verniz, PIV: técnica da pintura invertida com verniz. A leitura de cor foi realizada por meio de um espectrofotômetro de reflexão ultravioleta visível utilizando o sistema CIE L*a*b*, antes e após polimerização, e após 252, 504 e 1008 de envelhecimento acelerado. Os dados obtidos foram submetidos à análise de variância (ANOVA), e teste de Tukey (p<0,05). O teste de cor mostrou que após polimerização e envelhecimento acelerado todas as amostras apresentaram alteração significativa da cor, porém, as amostras com verniz protetor de tinta tiveram menor alteração em todos os períodos analisados. / Ocular prostheses are responsible not only for the recovery of aesthetic but also for the self-esteem of the anophthalmic patient. The techniques used to fabricate ocular prosthesis should result in artificial iris with adequate aesthetic and natural appearance. When such characteristics are not achieved, the fabrication of new prosthesis is indicated even in the presence of good fit of the old prosthesis. Additionally, the color instability of iris is the most relevant factor that affects the longevity of ocular prosthesis, and is related to the polymerization process of the acrylic resin and its clinical use over time. Therefore, the present study investigated the color alteration of artificial iris buttons obtained by different techniques after polymerization and accelerated aging. A total of 60 samples simulating an ocular prosthesis were fabricated and divided into groups (n=10) according to the technique used: PE – conventional technique without varnish; PEV - conventional technique with varnish; CA - Prefabricated cap technique without varnish; CAV - Prefabricated cap technique with varnished; PI - Reverse painting technique without varnish; PIV - Reverse painting technique with varnish. Color measurements were performed by using a visible ultraviolet reflection spectrophotometer with the CIE L*a*b* system, before and after polymerization, and after 252, 504 and 1008 hours of accelerated aging. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<.05). After polymerization and accelerated aging periods all samples exhibited statistically color alteration; however, the varnished samples had lower color change for all periods.
66

Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses oculares

Andreotti, Agda Marobo [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-31Bitstream added on 2015-03-03T12:07:03Z : No. of bitstreams: 1 000795011.pdf: 3623811 bytes, checksum: d8263b2bba7ed088e7be14e351d1311c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control – without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / FAPESP: 12/02907-0
67

Avaliação da resistência de união entre dentes artificiais e resinas acrílicas para base protética. Efeito de termociclagem /

Marra, Juliê. January 2007 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Débora Barros Barbosa / Banca: Renata Garcia Fonseca / Resumo: O estudo avaliou a resistência de união entre dentes artificiais e resinas acrílicas para base protética e o efeito da termociclagem. Para isso foram utilizadas três marcas comerciais de dentes artificiais de resina acrílica (Biotone, Trilux e Ivoclar) e quatro de resinas acrílicas para base protética, sendo duas termopolimerizáveis por banho de água quente (Lucitone 550 e QC-20), uma polimerizada por meio da energia de microondas (Acron MC) e uma fotopolimerizável (Versyo.com). Vinte espécimes foram confeccionados para cada combinação de dente artificial e resina acrílica e divididos em 2 grupos (n=10) nas seguintes condições experimentais: sem a ação da termociclagem (grupo controle) e com a ação da termociclagem. Os espécimes dos grupos com termociclagem foram submetidos 5000 ciclos com temperatura variando entre 4º e 60ºC e tempo de imersão de 30 segundos em cada. Em seguida, os espécimes foram submetidos ao ensaio mecânico de cisalhamento em máquina universal a uma velocidade de 1mm/min. Os dados foram submetidos à análise de variância a três fatores seguida pelo teste de Bonferroni para comparações múltiplas (a=0,05). Os resultados demonstraram que a termociclagem reduziu significantemente os valores médios de resistência de união da resina acrílica Lucitone 550 quando associada aos dentes Biotone e Trilux e com a resina Versyo.com e os dentes Ivoclar P<0,05). E que as médias de resistência de união das resinas acrílicas Acron MC e Lucitone 550 quando associadas aos dentes Ivoclar aumentaram significantemente após a ação da termociclagem (P<0,05). Conclui-se que algumas combinações de dente artificial e resina acrílica podem ser mais afetadas pela ação da termociclagem, e esses efeitos variam de acordo com os materiais selecionados. / Abstract: The purpose of this in vitro study was to evaluate the bond strength of denture base resins to acrylic denture teeth and the effect of the thermocycling. Three acrylic denture teeth (Biotone, Trilux and Ivoclar) were chosen for bonding to four denture base resins: one microwave-polymerized (Acron MC), two heat-polymerized (Lucitone 550 and QC-20) and one light-polymerized (Versyo.com). Twenty specimens were produced for each denture base/acrylic denture tooth combination and were divided into 2 groups (n=10) as follows: without thermocycling (control groups) and thermocycled groups that were submitted to 5,000 cycles between 4º and 60ºC with a dwell time of 30 seconds in each bath. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min until fracture. Statistical analysis of the results was carried out with 3-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (a=.05). A significant interaction between denture base resin, acrylic denture teeth and thermocycling (P<.001) was observed. The shear bond strengths of Lucitone 550/Biotone, Lucitone 550/Trilux and Versyo.com/Ivoclar specimens were significantly decreased by thermocycling compared with the corresponding control groups (P<.05). The shear bond strengths of Acron/Ivoclar and Lucitone/Ivoclar specimens significantly increased after thermocycling (P<.05). Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; the effects vary based upon the materials used. / Mestre
68

Efeitos de diferentes tratamentos a plasma e de variações na coleta, preparo e pré-condicionamento com saliva na adesão de Candida a uma resina para a base de prótese /

Zamperini, Camila Andrade. January 2011 (has links)
Orientador: Ana Lucia Machado / Banca: Wander José da Silva / Banca: Helena de Freitas Oliveira Paranhos / Banca: Francisco de Assis Mollo Junior / Banca: Gelson Luis Adabo / Resumo: A adesão de Candida às superfícies protéticas é o passo inicial para ocorrência da estomatite protética. Entre os diversos fatores envolvidos na adesão de Candida spp. às superfícies poliméricas estão as interações hidrofóbicas e eletrostáticas, a rugosidade superficial e a película salivar. Assim, os objetivos deste estudo foram: investigar o potencial de diferentes tratamentos a plasma (Ar/50W; ArO2/70W; AAt/130W; ArSF6/70W) de modificar uma resina acrílica para base de prótese (VIPIWAVE) para reduzir a aderência de Candida albicans (ATCC 90028), avaliada pelo ensaio de XTT e cristal violeta. O efeito da rugosidade de superfície e do pré-condicionamento com saliva também foram avaliados; investigar se modificações de superfícies por meio de dois tratamentos a plasma (Ar/50W; AAt/130W) reduziriam a aderência de Candida glabrata (ATCC 2001), avaliada pela coloração cristal violeta, sobre superfícies lisas de resina acrílica. Além disso, o efeito do pré-condicionamento com saliva também foi avaliado; e ainda, avaliar se variações nos períodos de pré-condicionamento com saliva (0 min; 30 min; 60 min; 180 min; 720 min), nos parâmetros de centrifugação (velocidade e tempo) e número de doadores de saliva influenciariam os resultados de adesão de Candida albicans a uma resina acrílica para base de prótese, avaliada por meio do ensaio de XTT e coloração cristal violeta. Além disso, a correlação entre os dois métodos utilizados para avaliação da adesão de Candida albicans também foi avaliada. Os resultados obtidos demonstraram que os tratamentos a plasma são efetivos para modificação da hidrofobicidade de superfície ou incorporação de átomos de flúor na superfície da resina acrílica. Entretanto, após os tratamentos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The adhesion of Candida to denture surfaces is the initial step for occurrence of denture stomatitis. Among the various factors involved on Candida adhesion to polymeric surfaces are the hydrophobic and eletrostatic interactions, surface roughness and pellicle salivary. Hence, the aims of this study were: to investigate the potential of different plasma treatments (Ar/50W; ArO2/70W; AAt/130W; ArSF6/70W) to modify a denture base acrylic resin (VIPIWAVE) to reduce the Candida albicans adhesion (ATCC 90028), evaluated by XTT reduction assay and crystal violet staining. The effect of surface roughness and saliva coating was also evaluated; to investigate the potential of two plasma treatments (Ar/50W; AAt/130W) to modify a denture base acrylic resin to reduce the Candida glabrata adhesion (ATCC 2001), evaluated by crystal violet staining. Moreover, the effect of saliva coating was also evaluated; and to assess the effect of different periods of preconditioning with saliva (0 min; 30 min; 60 min; 180 min; 720 min), variations in the centrifugation parameters (speed and time) and number of donors of saliva on Candida albicans adhesion to a denture base resin using crystal violet staining and XTT reduction assay. Additionally, the correlation between the two methods used for assessing Candida albicans adhesion was also evaluated. The results obtained demonstrated that the plasma treatments were effective in modifying hydrophobicity or incorporation of fluorine into acrylic resin. However, there were significant alterations in the contact angle measured after immersion in water. Groups ArO2/70W and ArSF6/70W showed significantly lower absorbance readings to Candida albicans adhesion than the other groups. No statistically significant difference in the adherence of Candida albicans, evaluated by... (Complete abstract click electronic access below) / Doutor
69

Validação de um método de análise da porosidade em resinas acrílicas para base de prótese

Pero, Ana Carolina [UNESP] [UNESP] 05 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-05Bitstream added on 2014-06-13T20:45:47Z : No. of bitstreams: 1 pero_ac_dr_arafo.pdf: 864877 bytes, checksum: 4fe3b68d34300fa34113379f9b184bcf (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / O estudo da porosidade em resina acrílica para base de prótese tem sido realizado por meio de diversos métodos, entre eles o método que associa a porosidade com a sorção de água pela resina acrílica tendo como base o Princípio de Arquimedes. O objetivo do presente estudo foi validar um método de análise da porosidade por meio de sorção de água em resinas acrílicas para base protética por meio da determinação de uma solução adequada de armazenamento dos espécimes (aw ótima), em função de dois formatos de espécime (retangular, de acordo com a norma ISO 1567 e formato de uma base protética) e duas resinas acrílicas para base protética processadas de maneiras distintas: banho de água (Clássico) e microondas (Acron MC). As soluções de armazenamento utilizadas nesse estudo corresponderam a soluções de cloreto de cálcio anidro a 25%, 50%, 75%, e água destilada pura. Após a determinação dos grupos onde se estabeleceu a aw ótima, foram calculados o fator de porosidade (FP) e o coeficiente de difusão (D) nesses grupos bem como para os grupos armazenados em água destilada pura. Os resultados de FP foram comparados por meio de análise de variância (ANOVA) para um fator, seguida pelo teste HSD de Tukey. Para o D, empregou-se o teste de Kruskal-Wallis, seguido do teste de Dunn (Acron MC, P=0,003; Clássico, P=0,020). Para todos os procedimentos estatísticos, o nível de significância foi _= 0,05. A partir dos resultados foi possível concluir que para a resina polimerizada em microondas (Acron MC), a aw ótima é uma solução de cloreto de cálcio anidro a 50% para o formato base protética e de 75% para o formato ISO. Já para a resina polimerizada em banho de água quente (Clássico), concluiu-se que os espécimes para avaliação da porosidade devem ser armazenados em solução de cloreto de cálcio anidro a 75% para o formato base protética e 50 % no formato ISO. / The study of porosity in acrylic resin has been carried out by means of diverse methods, among them the method that associates the porosity with the water sorption by acrylic resin which is based on Archimedes’ Principle. The aim of the present study was to validate a method of porosity analysis by means of water sorption in denture base resins by the determination of an adequate solution of specimens storage (optimal aw), as a function of two specimen shapes (rectangular in accordance with ISO 1567 and denture base shape) and two denture base resins processed in different ways: water bath (Clássico) and microwave-polymerized (Acron MC). The storage solutions used in this study were anhydrous calcium chloride solutions at 25%, 50%, 75%, and distilled water. After the determination of optimal aw, porosity factor (FP) and diffusion coefficient (D) have been calculated in these groups and for the groups stored in distilled water. FP results have been compared by one-way ANOVA, followed for Tukey HSD test. For D, Kruskal-Wallis test was performed, followed by Dunn test (Acron MC, P=0,003; Clássico, P=0,020). For all the statistical procedures, the level of significance was _= .05. From the results, it was possible to conclude that for Classico resin, the storage solution indicated for porosity evaluation is anhydrous calcium chloride solution at 50% for denture base shape, and 75 % for ISO shape. For the water bath-polymerized resin (Classico), it was concluded that the specimens for porosity evaluation must be stored in anhydrous calcium chloride solution at 75% for denture base shape and 50 % for ISO shape. It was also concluded that, for the same resin, specimen shape did not influence on FP since the specimens are stored in optimal aw established in this study.
70

Análise da porosidade superficial em materiais reembasadores rígidos. Efeito da desinfecção por irradiação de energia de microondas

Novais, Polyanna Maria Rocha [UNESP] 28 July 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-07-28Bitstream added on 2014-06-13T20:06:07Z : No. of bitstreams: 1 novais_pmr_dr_arafo.pdf: 1022914 bytes, checksum: ecb7684ee99763ab0c4f40e266a5be69 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito da desinfecção por irradiação de energia de microondas na porosidade superficial de quatro reembasadores rígidos (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR, Ufi Gel Hard - UGH) e uma resina termopolimerizável para base de prótese (Lucitone 550 - L). Concluiu-se que: 1) As irradiações por energia de microondas aumentaram o número de poros para o material K (P<0,05), quando este foi submetido a 7 ciclos, em relação ao G1. Entretanto, a área total de poros não exibiu essa influência (P>0,05) em todos os grupos avaliados. 2) O material NT não sofreu efeito das irradiações para o número de poros em todos os grupos. Entretanto, a área de poros foi reduzida (P<0,05), quando foram utilizados 7 ciclos (G3), em comparação a 2 ciclos (G2). 3) As microondas reduziram o número de poros para o material TR (P<0,05), quando este foi submetido a 7 ciclos, em comparação ao G1 e G2. Sua área total de poros, no G3, exibiu redução significativa, em relação aos demais grupos avaliados. 4) A resina UGH, quando submetida a 7 ciclos de irradiação (G3), teve o número de poros reduzido (P<0,05), em relação ao G1 e G4. Entretanto, a área total de poros foi estatisticamente igual para todos os grupos. 5) O número e a área de poros do material L não foram influenciados (P>0,05) pelas irradiações. / This study evaluated the effect of microwave irradiation on the surface porosity of four hard chairside reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard-UGH) and one heat-polymerizing denture base acrylic resin (Lucitone 550-L). It was concluded that 1) Microwave irradiation promoted a significant increased (P<.05) in the number of pores for material K after 7 cycles; however, the total area of pores was not affect by irradiation in all groups evaluated. 2) Material NT was not affected by irradiation for the number of pores; however, the total area of pores was decrease after 7 cycles, when compared to G2. 3) For material TR, microwave irradiation decreased (P<.05) the number of pores after 7 cycles, compared to G1 and G2. The total area of pores of G3 was significantly decreased after 7 cycles. 4) Material UGH showed a significant decrease (P<.05) for number of pores when submitted to 7 cycles, compared to G1 and G4; however, the total area of pores was statically equal in all groups evaluated 5) For material L, the number and total area of pores were not affected by irradiations.

Page generated in 0.0511 seconds