• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 2
  • Tagged with
  • 5
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Étude théorique et expérimentale d'une servo-commande hydraulique de vitesse

Lequoc, Sinh January 1968 (has links)
Une procédure systématique pour la conception „des servocommandes électrohydrauliques a toujours été la question fondamentale qui préoccupe certains chercheurs. On constate, dans l'étude linéaire des servocommandes, que les techniques de simulation peuvent être utilisées, sans recourir a des essaies sur un prototype, comme moyen de prédiction des caractéristiques d'un système hydraulique. Dans le but de contribuer à l'étude de ce problème, nous avons développé un modèle mathématique d'une servocommande hydraulique de vitesse, en conservant certaines non-linéarités lorsqu'il y a lieu. Le modèle est ensuite simulé sur l'ordinateur digital, et les résultats sont comparés avec les mesures expérimentales sur un système réel spécialement conçu à cette fin. Des pièces standards ont été choisies afin d'avoir une plus grande gamme d'application industrielle. Il a été constaté que le modèle simulé représente d'une manière satisfaisante le système physique. Utilisant les méthodes générales présentées dans ce texte et à partir des spécifications données par le manufacturier, on peut alors vérifier les caractéristiques du système futur à l'aide du programme de simulation proposé. Finalement, il n'y a aucun doute que cette méthode de conception est une des plus économiques au point de vue temps et coût.
2

Une analyse de système

Leroudier, Jacques 10 April 1973 (has links) (PDF)
.
3

PMU based situation awareness for smart distribution grids / Unités de mesure de phaseur dans le cadre des réseaux de distribution électrique intelligents

Frazao, Rodrigo José Albuquerque 14 October 2015 (has links)
Une infrastructure robuste de surveillance basée sur des mesures numériques classiques est souvent utilisée pour permettre une gestion efficace du réseau de distribution électrique, néanmoins les mesures de phaseurs synchronisés, également connu comme synchrophaseurs, sont particulièrement efficaces pour améliorer la capacité de gestion et la surveillance de ces réseaux. Le synchrophaseur est un phaseur numériquement calculé à partir des échantillons de données en utilisant une source temporelle absolue pour un horodatage extrêmement précis des mesures effectuées.De ce fait, les applications des synchrophaseurs sont très nombreuses dans les réseaux électriques, en particulier dans les réseaux de transport. Ils permettent notamment de mesurer la différence angulaire entre les noeuds, l'estimation d'état linéaire, détecter l'îlotage, surveiller la stabilité oscillatoire, et détecter et identifier les défauts. Ainsi, nous pourrions être amenés à croire que pour apporter les avantages bien connus des mesures synchronisées vers les réseaux de distribution électriques, il serait seulement nécessaire de placer les Unités de Mesure de Phaseur, également connu par l'abréviation anglophone PMU, d'une manière directe dans l'environnement de la distribution électrique. Malheureusement, cette tâchen'est pas aussi évidente qu'elle n'y paraît.Les réseaux de distribution électriques et les réseaux de transport ont des caractéristiques opérationnelles différentes, donc les PMUs dédiées aux réseaux de distribution doivent avoir des caractéristiques différentes de celles consacrées aux réseaux haute tension. Les réseaux de distribution intelligents possèdent des longueurs de ligne plus courtes en produisant une ouverture angulaire plus petite entre les noeuds adjacents. En outre, le contenu harmonique élevé et la déviation en fréquence imposent aussi des défis pour l'estimation des phaseurs. Les appareils synchronisés avancés dédiés pour la surveillance du réseau de distribution doivent surmonter ces défis afin de mener la précision des mesures au-delà des exigences actuelles.Cette problématique globale est traitée et évaluée dans la présente thèse. La précision de l'estimation de phaseur est directement liée à la performance de l'algorithme utilisé pour traiter les données. Une grande robustesse contre les effets pernicieux qui peuvent dégrader la qualité des estimations est fortement souhaitée. De ce fait, trois algorithmes adaptifs en fréquence sont présentés en visant l'amélioration du processus d'estimation des mesures de phaseurs dans les réseaux de distribution actifs. Plusieurs simulations en utilisant des signaux corrompus sont réalisées pour évaluer leurs performances dans des conditions statiques et/ou dynamiques.Prenant en compte l'estimation précise des phaseurs, quatre applications potentielles sont présentées pour augmenter la perception, la compréhension et la projection des actions dans les réseaux de distribution. Des contributions sont apportées concernant le circuit équivalent de Thévenin vu par le point de couplage commun (PCC) entre la production décentralisée et les réseaux de distribution. Des contributions sont également apportées pour les équivalents dynamiques externes et l'évaluation de la chute de tension dans les réseaux moyenne-tension radiaux, ainsi que l'évaluation de la problématique des harmoniques pour l'amélioration de la méthode classique nomée PH (puissance active harmonique) pour détecter à la fois la principale source de pollution harmonique et le vrai flux de puissance harmonique sous déviation en fréquence.Le sujet des mesures de phaseurs synchronisés dans le réseaux électrique de distribution est encore peu exploré et les questionnements quant à son applicabilité sont communs, néanmoins cette thèse vise à fournir des propositions pour contribuer à l'avènement de mesures de phaseurs dans l'environnement de la distribution électrique. / Robust metering infrastructure based on classical digital measurements has been used to enable a comprehensive power distribution network management, however synchronized phasor measurements, also known as synchrophasors, are especially welcome to improve the overall framework capabilities. Synchrophasor is a phasor digitally computed from data samples using an absolute and accuracy time source as reference. In this way, since the absolute time source has sufficient accuracy to synchronize voltage and current measurements at geographically distant locations, it is possible to extract valuable informations of the real grid operating status without full knowledge of its characteristics.Due to this fact, applications of synchronized phasor measurements in wide-area management systems (WAMSs) have been achieved. Angular separation, linear state estimation, islanding detection, oscillatory stability, and disturbance location identification are some of the several applications that have been proposed. Thus, we could be lead to believe that to bring the well-known benefits of the synchronized measurements toward electric distribution grids it is only required to place in a straightforward manner conventional Phasor Measurement Units (PMUs) into the electric distribution environment. Unfortunately, this is not as simple as it seems.Electric power distribution systems and high-voltage power systems have different operational characteristics, hence PMUs or PMU-enabled IEDs dedicated to distribution systems should have different features from those devoted to the high-voltage systems. Active distribution grids with shorter line lengths produce smaller angular aperture between their adjacent busbars. In addition, high harmonic content and frequency deviation impose more challenges for estimating phasors. Generally, frequency deviation is related to high-voltage power systems, however, due to the interconnected nature of the overall power system, frequency deviation can be propagated toward the distribution grid. The integration of multiple high-rate DERs with poor control capabilities can also impose local frequency drift. Advanced synchronized devices dedicated to smart monitoring framework must overcome these challenges in order to lead the measurement accuracy beyond the levels stipulated by current standard requirements.This overall problematic is treated and evaluated in the present thesis. Phasor estimation accuracy is directly related to the algorithm's performance used for processing the incoming data. Robustness against pernicious effects that can degrade the quality of the estimates is highly desired. Due to this fact, three frequency-adaptive algorithms are presented aiming to boost the phasor estimation process in active distribution grids. Several simulations using spurious and distorted signals are performed for evaluating their performances under static and/or dynamic conditions.Taking into account accurate phasor estimates, four potential applications are presented seeking to increase situational awareness in distribution environment. Contributions are presented concerning online Thévenin's equivalent (TE) circuit seen by the Point of Common Coupling (PCC) between DERs and the grid side, dynamic external equivalents and online three-phase voltage drop assessment in primary radial distribution grids, as well as assessment of harmonic issues for improving the classical PH method (harmonic active power) to detect both the main source of harmonic pollution and true power flow direction under frequency deviation.The issue of synchronized phasor measurements in electric power distribution systems is still underexplored and suspicions about its applicability are common, however this thesis aims to provide propositions to contribute with the advent of phasor measurements in electric distribution environment.
4

Analyse et modélisation de l'effet de l'Interleukine 7 chez les patients infectés par le VIH / Analysing and modeling the effect of interleukin 7 in HIV-infected patients

Villain, Laura 13 December 2018 (has links)
Chez les patients infectés par le VIH, les traitements antirétroviraux empêchent la réplicationvirale, ce qui est suivi, dans la plupart des cas, par une restauration de la population des lymphocytesT CD4+ (CD4). Néanmoins ce n’est pas le cas pour certains patients appelés patients àfaible réponse immunitaire. Des injections d’interleukine-7 (IL7) exogène, une cytokine impliquéedans l’homéostasie des CD4, sont considérées afin de maintenir les taux de CD4 au-dessus de500 cellules par μL, taux au-dessus duquel les patients ont une espérance de vie comparable auxpersonnes non infectées par le VIH. Les essais INSPIRE ont évalué l’effet d’injections répétéesd’IL7 chez les patients à faible réponse immunologique.Nous présentons plusieurs modèles mécanistes de l’effet des injections d’IL7 sur les CD4, quiincluent des effets aléatoires afin de tenir compte de la variabilité inter-individuelle. En utilisantces modèles avec une approche Bayésienne, les paramètres individuels d’un nouveau patient sontéchantillonnés, ce qui nous permet de faire des prédictions sur sa dynamique de CD4 et donc depersonnaliser le traitement. Nous proposons quatre protocoles adaptatifs permettant de limiter letemps passé sous 500 CD4 par μL, sans pour autant augmenter le nombre d’injections. Ces protocolesont été implémentés dans une application Shiny présentant une interface facile d’utilisation,et pourront être testés lors d’essais cliniques.Le réservoir viral, principalement constitué de CD4 quiescentes infectées, est la première barrièreà l’éradication du VIH. Les injections d’IL7 entrainent une augmentation du nombre deCD4 et donc du réservoir viral ; la question est alors de savoir si les injections provoquent denouvelles infections cellulaires ou si le réservoir augmente de la même façon que les CD4. Nousconcluons que si quelques patients ont présenté des dynamiques de marqueurs compatibles avecla survenue de nouvelles infections de cellules, ce n’est pas le cas de la majorité des patients. Laconfirmation de ces phénomènes et la caractérisation de potentiels patients à risque nécessite desdonnées supplémentaires mesurables dans un essai clinique. / In HIV infected patients, antiretroviral therapy suppresses the viral replication which is followedin most patients by a restoration of the CD4+ T cells (CD4) pool. However, it is not the case forsome patients called low immunological responders. Injections of interleukin-7 (IL7), a cytokineinvolved in the CD4 homeostasis, are considered in order to maintain the CD4 levels above 500cells per μL, the level at which life expectancy is similar to that of the non-infected. INSPIREtrials evaluated the effect of repeated injections of IL7 on low immunological responders.We present a few mechanistic models of the effect of IL7 injections on CD4, which includerandom effects to account for inter-individual variability. Using these models with a Bayesianapproach, the individual parameters of a new patient are sampled, which allows us to makepredictions about its CD4 dynamics and thus to personalize the treatment. We propose fouradaptive protocols that limit the time spent under 500 CD4 per μL, without increasing thenumber of injections. Those protocols are implemented into a Shiny app with an easy to useinterface, and they could be tested during clinical trials.The viral reservoir, mainly made up of quiescent infected CD4, is the main obstacle to HIVeradication. IL7 injections induce an increase of the level of CD4, hence of the viral reservoir ; thequestion is then to determine if the injections induce new cell infections or if the reservoir increasesin the same way as CD4. We conclude that while some patients presented marker dynamicsconsistent with the occurrence of new cell infections, this is not the case for the majority ofpatients. Confirmation of these events and characterization of potential at-risk patients requiresadditional measurable data in a clinical trial.
5

Adaptive algorithms for poromechanics and poroplasticity / Algorithmes adaptatifs pour la poro-mécanique et la poro-plasticité

Riedlbeck, Rita 27 November 2017 (has links)
Dans cette thèse nous développons des estimations d'erreur a posteriori par équilibrage de flux pour la poro-mécanique et la poro-plasticité.En se basant sur ces estimations, nous proposons des algorithmes adaptatifs pour la résolution numérique de problèmes en mécanique des sols.Le premier chapitre traite des problèmes en poro-élasticité linéaire.Nous obtenons une borne garantie sur l'erreur en utilisant des reconstructions équilibrées et $H({rm div})$-conformes de la vitesse de Darcy et du tenseur de contraintes mécaniques.Nous appliquons cette estimation dans un algorithme adaptif pour équilibrer les composantes de l'erreur provenant de la discrétisation en espace et en temps pour des simulations en deux dimensions.La contribution principale du chapitre porte sur la reconstruction symétrique du tenseur de contraintes.Dans le deuxième chapitre nous proposons une deuxième technique de reconstruction du tenseur de contraintes dans le cadre de l'élasticité nonlinéaire.En imposant la symétrie faiblement, cette technique améliore les temps de calcul et facilite l'implémentation.Nous démontrons l'éfficacité locale et globale des estimateurs obtenus avec cette reconstruction pour une grande classe de lois en hyperélasticité.En ajoutant un estimateur de l'erreur de linéarisation, nous introduisons des critères d'arrêt adaptatifs pour le solveur de linéarisation.Le troisième chapitre est consacré à l'application industrielle des résultats obtenus. Nous appliquons un algorithme adaptatif à des problèmes poro-mécaniques en trois dimensions avec des lois de comportement mécanique élasto-plastiques. / In this Ph.D. thesis we develop equilibrated flux a posteriori error estimates for poro-mechanical and poro-plasticity problems.Based on these estimations we propose adaptive algorithms for the numerical solution of problems in soil mechanics.The first chapter deals with linear poro-elasticity problems.Using equilibrated $H({rm div})$-conforming flux reconstructions of the Darcy velocity and the mechanical stress tensor, we obtain a guaranteed upper bound on the error.We apply this estimate in an adaptive algorithm balancing the space and time discretisation error components in simulations in two space dimensions.The main contribution of this chapter is the symmetric reconstruction of the stress tensor.In the second chapter we propose another reconstruction technique for the stress tensor, while considering nonlinear elasticity problems.By imposing the symmetry of the tensor only weakly, we reduce computation time and simplify the implementation.We prove that the estimate obtained using this stress reconstuction is locally and globally efficient for a wide range of hyperelasticity problems.We add a linearization error estimator, enabling us to introduce adaptive stopping criteria for the linearization solver.The third chapter adresses the industrial application of the obtained results.We apply an adaptive algorithm to three-dimensional poro-mechanical problems involving elasto-plastic mechanical behavior laws.

Page generated in 0.0522 seconds