• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 1
  • Tagged with
  • 77
  • 55
  • 50
  • 48
  • 25
  • 19
  • 19
  • 19
  • 17
  • 16
  • 16
  • 15
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação da resistência de união da interface cerâmica Y-TZP/dentina humana utilizando diferentes agentes de cimentação e tratamentos de superfície / Evaluation of bond strength of Y-TZP / dentin ceramic interface using different cementing agents and surface treatments

Isabela da Rocha Silva 25 November 2015 (has links)
Hipótese do estudo: A hipótese do presente estudo é de que o cimento resinoso autoadesivo U200 apresente melhores valores de resistência adesiva entre os substratos zircônia Y-TZP/dentina humana, em comparação com o cimento resinoso convencional C&B Cement, utilizando dois tratamentos de superfície distintos (jateamento com óxido de alumínio e silicatização (Rocatec) na superfície da zircônia; e que o tratamento de superfície influencie positivamente os resultados de resistência adesiva. Objetivos: Avaliar por meio de teste de microcisalhamento a resistência adesiva da zircônia Y-TZP cimentada à dentina humana utilizando diferentes agentes de cimentação e tratamentos de superfície. Método: Foram utilizados 42 molares humanos recém extraídos, incluídos 2/3 de suas raízes em resina acrílica. A superfície oclusal foi desgastada até exposição da dentina média, tratada de acordo com as recomendações dos fabricantes dos cimentos. Quarenta e dois blocos de zircônia Y-TZP (10x10x3mm) foram divididos aleatoriamente em três grupos de acordo com o tratamento de superfície (sem tratamento-controle, jateamento com óxido de alumínio-Al2O3 ou silicatização-Rocatec). Todos os blocos de zircônia foram cimentados seguindo as recomendações dos fabricantes e divididos em seis grupos combinando os diferentes tratamentos de superfície e agentes de cimentação. Os espécimes foram armazenados em água destilada 37C por 24h e após este período foram submetidos ao teste de microcisalhamento em máquina de ensaios universal (Shimadzu AGX) com velocidade constante de 0,5mm/min até ocorrer fratura da interface. Os valores foram obtidos em Mpa e as superfícies de fraturas avaliadas e classificadas em: adesiva, coesiva e mista. As médias dos valores de resistência de união e a porcentagem das fraturas foram calculadas, e os valores submetidos à análise estatística, utilizando os testes Análise de Variância (two way) e pos-hoc teste T de Student, adotando p<0,05. Resultados: Quanto ao agente de cimentação os resultados obtidos para os grupos sem tratamento de superfície o cimento autoadesivo U200 apresentou melhor performance quando comparado ao cimento convencional C&B Cement; os grupos submetidos ao jateamento com Al2O3 e Rocatec não apresentaram diferença estatística entre os cimentos U200 e C&B Cement. Quanto à analise de superfície, os grupos cimentados com C&B e U200 apresentaram predominantemente falhas de natureza mista. Conclusão: Com base nos resultados encontrados no presente estudo foi possível concluir que o tratamento de superfície que melhor influenciou a resistência adesiva foi o jateamento com Al2O3, atendendo melhor os dois agentes de cimentação. Quanto ao agente de cimentação o U200 apresentou os melhores resultados sem tratamento de superfície. O C&B Cement e U200 apresentaram valores semelhantes com a superfície jateada com Al2O3. Para o Rocatec, os cimentos U200 e C&B Cement apresentaram valores semelhantes, entretanto menores do que os valores conseguidos para o Al2O3. / Study hypothesis: The hypothesis of this study is that the resin cement Self Adhesive U200 present best values of bond strength between zirconia substrates Y-TZP / dentin compared to conventional resin cement C & B Cement, using two surface treatments distinct (sandblasting with aluminum and silica coating (Rocatec) oxide on the surface of zirconia, and the surface treatment positively influence the bond strength. Objectives: To assess via microshear test the bond strength of zirconia Y-TZP cemented to dentin human using different cementing agents and surface treatments. Method:. freshly extracted human molars 42, including two thirds of its roots in acrylic resin were used the occlusal surface was worn until the middle dentin exposure, treated according to the recommendations of the cement manufacturers. Forty-two blocks of Y-TZP zirconia (10x10x3mm) were randomly divided into three groups according to the surface treatment (untreated control, blasting with aluminum oxide or silica coating-Al2O3-Rocatec). All zirconia blocks were cemented following the manufacturers recommendations and divided into six groups combining different surface treatments and cementing agents. The specimens were stored in distilled water 37 C for 24 h and after this period underwent microshear test in a universal testing (Shimadzu AGX) machine with constant speed of 0.5 mm / min until fracture occurs interface. The values were obtained in MPa and the fracture surfaces evaluated and classified as: adhesive, cohesive and mixed. The average values of union strength and the percentage of fractures were calculated, and values subjected to statistical analysis using analysis of variance tests (two way) and post-hoc Students t test, considering p <0.05. Results: Regarding the cementing agent the results for the groups without surface treatment U200 self-adhesive cement showed better performance when compared to conventional cement C & B Cement; groups subjected to blasting with Al2O3 and Rocatec showed no statistical difference between the U200 and cements C & B Cement. As for the analysis of surface groups cemented with C & B and U200 were mostly mixed nature of failures. Conclusion: Based on results of this study it was concluded that the surface treatment that best influenced the bond strength was blasting with Al2O3 to better serve the two cementing agents. As the cementing agent U200 showed the best results without surface treatment. The C & B Cement and U200 showed similar values with the surface sandblasted with Al2O3. Rocatec to the U200 and cement Cement B & C showed similar, though lower than the values obtained for Al2O3 values.
72

Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais / Blood contamination and cleaning substances influence on adhesion

Tachibana, Arlene 04 August 2008 (has links)
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva. / Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.
73

Laser de Er,Cr:YSGG em condutos radiculares preparados para cimentação de núcleos protéicos / The utilization of Er,Cr:YSGG laser in prosthetic post space preparation before post placement

Quinto Junior, José 19 December 2011 (has links)
O objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado. / The aim of this study was to evaluate the influence of the Er,Cr:YSGG laser irradiation in the prosthetic post space before FRC Postec placement using three different adhesive systems (self-etching- Panavia F; total-etching- Excite DSC + Variolink II e self adhesive - RelyX Unicem Aplicap). According to ISO-TS 11405, sectioned at the CEJ, human dental single roots were endodontically treated with rotatory instruments and filled with gutta-percha points and sealer. Were used at 40 J/cm2 an axial Z4 laser tip (400 m diameter) and a radial (side firing) RFT4 laser tip (415 m diameter). This density of energy was experimentally determinated observing morphological changes in SEM images due to an increase range in the energy applied to dentinal root canal surface. At the length between 32 and 49 J/cm2 most of the intracanal dentinal tubules were open. The temperature increase was within the biological safe suggesting a feasible clinical use. Each root canal was irradiated five times with helicoidal movements from apical to cervical, with 20 seconds interval. FRC Postec were immediately cemented and randomly divided in nine groups (n=10). Each root canal was cut in six discs for push out test, were the maximum failure load was obtained and the bond strength was calculated as a function of post bonded area. The bond strength for the irradiated groups was superior among all control groups. The evaluation of bond strength among root region (cervical, middle and apical) was performed and differences were observed. The self-adhesive (RelyX Unicem Aplicap) system was noted superior among all irradiated groups and all regions. Chemical changes were analyzed by FTIR due to dental root portion and dentinal tubules orientation to laser beam direction. The FTIR spectra obtained indicated changes due to tubules orientation and root canal portion irradiated such as the proportion among the compositional ratio without causing chemical changes. These compositional ratio alterations may affect the bond strength results. The irradiation with Er,Cr:YSGG laser on dentinal walls of a prosthetic post space preparation before the post cementation, as suggested in this study, may increase the bond strength between the post and root canal dentin depending upon the luting cement that is used.
74

Análise morfológica e da resistência adesiva dos tecidos dentais duros irradiados com lasers de pulsos ultracurtos / Evaluation of dental hard tissues irradiated with ultra-short pulsed lasers. Influence on surface morphology and microtensile bond strength

Silva, Marina Stella Bello 16 September 2010 (has links)
O desenvolvimento da Odontologia Restauradora culminou com a era das restaurações estéticas adesivas e da intervenção minimamente invasiva, para as quais técnicas inovadoras e materiais de última geração vêm sendo constantemente introduzidos. As técnicas conservadoras visam não somente a remoção do substrato dental cariado, mas também o preparo das paredes da cavidade para a realização da restauração adesiva. Este estudo visou avaliar a possibilidade de introdução dos lasers de pulsos ultracurtos na Odontologia Restauradora, com o intuito de suprir os requisitos básicos para a realização de uma restauração conservadora adequada. A intenção foi de manter os benefícios já conhecidos relacionados à remoção seletiva de cárie com os lasers de alta potência, bem como superar as desvantagens relacionadas às fontes lasers atualmente disponíveis para este fim, como aumento excessivo de temperatura e adesão prejudicada da superfície irradiada à resina composta. Para a melhor avaliação da interação entre os lasers de pulsos ultracurtos e o substrato dental, os experimentos foram realizados em três fases. A Fase 1 visou avaliar o efeito de diferentes comprimentos de onda (355 nm, 532 nm, 1045 nm e 1064 nm), durações de pulso (pico e femtossegundos) e protocolos de irradiação (velocidade de escaneamento da superfície, espessura do espécime, método de refrigeração e taxa de repetição de pulso) em esmalte e dentina. Para a Fase 2, os parâmetros de irradiação que apresentaram resultados mais favoráveis na Fase 1 foram analisados para relacionar o aumento de temperatura com a taxa de ablação e a eficiência de ablação para cada parâmetro. A Fase 3 teve como objetivo analisar a interface adesiva e os valores de microtração da dentina irradiada com os parâmetros selecionados e estudados na Fase 2, utilizando sistemas adesivos do tipo condicione e lave e autocondicionante com diferentes protocolos de adesão (Clearfil SE Bond com e sem Primer, Adper Single Bond com e sem condicionamento ácido). Os resultados obtidos na Fase 1 indicam que a dentina e o esmalte irradiados com lasers de femtossegundos de 1045 nm e picossegundos de 1064 nm apresentam superfície rugosa livre de carbonização. Os protocolos de irradiação selecionados mostram que a irradiação deve ser conduzida com maior velocidade de escaneamento da superfície, e não há necessidade de refrigeração durante a irradiação. Todos os parâmetros utilizados promoveram ablação seletiva do substrato dental, e apresentaram maior taxa de ablação para dentina que para esmalte. A Fase 2 permitiu observar que todos os parâmetros de irradiação selecionados não provocaram aumento de temperatura maior que 6,1 ºC para esmalte e 4,6 ºC para dentina, quando o aumento de temperatura foi aferido no lado oposto ao irradiado, em espécimes de 1 mm de espessura e sem refrigeração. Exceção foi observada para a maior potência do laser de picossegundos, para a qual a temperatura aumentou até 12 ºC em esmalte e 15 ºC em dentina. Os valores obtidos no ensaio de microtração variaram de acordo com os parâmetros de irradiação e o sistema adesivo. A adesão à dentina irradiada com lasers de pulsos ultracurtos apresentou valores de resistência adesiva semelhantes ou significantemente maiores que os obtidos nos grupos controle, para todos os parâmetros de irradiação selecionados. Os resultados obtidos neste estudo indicam que os lasers de pulsos ultracurtos apresentaram resultados favoráveis para o preparo cavitário em esmalte e dentina em relação à morfologia produzida na superfície e ao aumento de temperatura provocado durante a irradiação. A resistência adesiva à dentina irradiada foi semelhante, ou mesmo significantemente maior que a obtida nos grupos controle. Portanto, os lasers de pulsos ultracurtos são considerados uma técnica promissora para a realização de intervenção minimamente invasiva com lasers de alta potência. / The development of restorative dentistry has reached the era of esthetic adhesive restorations and minimally invasive approach, for which innovative techniques and advanced materials are constantly introduced. Conservative techniques aim not only to remove carious dental substrate, but also to prepare cavity surfaces for adhesive restoration. The main objective of this study was to evaluate the possibility of introducing ultra-short pulsed lasers in Restorative Dentistry, in attempt to fulfill the basic requirements of adequate conservative restoration, by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages related to current laser sources available for this purpose, such as temperature increase and damaged adhesion to resin composite. In order to better evaluate the interaction between ultra-short pulsed lasers and dental substrates, experimental procedures were divided in three phases. Phase 1 aimed to evaluate the effect of different wavelengths (355 nm, 532 nm, 1,045 nm, and 1,064 nm), pulse durations (pico and femtoseconds) and irradiation protocols (surface scanning speed, sample thickness, cooling method, pulse repetition rate) on enamel and dentin. For Phase 2, laser parameters with most favorable results in Phase 1 were evaluated to relate temperature increase to ablation rate or ablation efficiency. Phase 3 aimed to analyze adhesive interface and microtensile bond strength to dentin irradiated with the selected parameters by using etch-and-rinse and self-etch adhesive systems with different bonding protocols (Clearfil SE Bond with and without Primer, Adper Single Bond with and without acid etching). The results of Phase 1 indicate that dentin and enamel irradiated with 1,045-nm fs-laser and 1,064-nm ps-laser present a rough surface without carbonization. Irradiation should be conducted with higher scanning speed, and no additional cooling during irradiation was necessary. All parameters provided selective tissue ablation, with higher ablations rate for dentin than enamel. Phase 2 indicated that all parameters tested provoked temperature increase of up to 6.1 ºC for enamel and 4.6 ºC for dentin, when temperature increase was measured at the back side of 1-mm thick samples without cooling during irradiation, except for higher power for ps-laser, for which temperature increased up to 12 ºC for enamel and 15 ºC for dentin. Microtensile bond strength values varied according to laser parameters and adhesive systems used. Adhesion to dentin irradiated with ultra-short pulsed lasers resulted in similar or significantly higher bond strength values than control groups, for all laser parameters analyzed. Based on the results of this study, ultra-short pulsed lasers presented favorable results for cavity preparation in dentin and enamel regarding surface morphology and temperature increase. Adhesion to irradiated dentin was either similar or superior to traditional techniques. Thus, ultra-short pulsed lasers are considered a promising technique for the promotion of laser-supported minimally invasive approach.
75

Laser de Er,Cr:YSGG em condutos radiculares preparados para cimentação de núcleos protéicos / The utilization of Er,Cr:YSGG laser in prosthetic post space preparation before post placement

José Quinto Junior 19 December 2011 (has links)
O objetivo deste estudo é avaliar a influência da irradiação com laser de Er,Cr:YSGG no espaço protético de condutos radiculares preparados para a fixação de pinos em fibra de vidro reforçados (FRC Postec®), avaliando-se o comportamento de três diferentes técnicas adesivas (self-etching= Panavia F®; total-etching= Excite DSC® + Variolink II® e self-adhesive= RelyX Unicem Aplicap®). Observaram-se as orientações da norma ISO-TS 11405 para a preparação das raízes dentais unirradiculares humanas. As amostras foram separadas na altura da junção amelo-dentinaria, tratadas endodonticamente com instrumentação rotatória e seladas com técnica de condensação lateral. Foram utilizados dois tipos diferentes de pontas de safira para irradiação intracanal o axial (Z4, 400 m de diâmetro) e o radial ou side firing (RFT4, 415 m de diâmetro) com densidade de energia de 40 J/cm2. Esta densidade de energia foi obtida como parte deste experimento, analisando-se diversos parâmetros de energia com os resultados morfológicos e térmicos obtidos. Nesta densidade, obtive-se grande quantidade de túbulos dentinários abertos e variação de temperatura segura para uso clínico. Cada raiz foi irradiada em cinco movimentos circulares, de apical para cervical, com intervalo de 20 segundos, entre elas. Os FRC Postec foram cimentados imediatamente após a irradiação e divididos randomicamente em nove grupos (n=10). Cada raiz foi seccionada em 6 discos de 1 mm de espessura para ensaio do tipo push-out, para a obtenção da força máxima de ruptura, e posterior cálculo da resistência de união adesiva em função da área de superfície do núcleo deslocado, resultando na pressão em MPa. A resistência de união adesiva nos grupos irradiados foi estatisticamente superior do que os grupos controle. Foram avaliadas as diferenças na resistência de união adesiva em diferentes porções do núcleo (cervical, médio e apical), onde o sistema adesivo tipo self-adhesive (RelyX Unicem Aplicap) teve o melhor resultado para os grupos irradiados. Avaliou-se por técnica de FTIR as diferenças químicas ocorridas na dentina intrarradicular irradiada com laser de Er,Cr:YSGG, em diferentes porções (cervical, médio e apical) em função da orientação dos túbulos. Foram observadas nos espectros de FTIR alterações na intensidade das bandas de algumas moléculas, indicando variação na quantidade da parte orgânica (amida I e amida II) após a irradiação, nas diferentes regiões dentais em função do feixe laser sobre a orientação dos túbulos dentinários, sem causar alterações na sua composição. Essas diferenças podem interferir no resultado da resistência de união adesiva. A técnica de utilização de laser de Er,Cr: YSGG em dentina radicular pré-cimentação de núcleo protético aumenta a resistência de união adesiva, na dependência do cimento utilizado. / The aim of this study was to evaluate the influence of the Er,Cr:YSGG laser irradiation in the prosthetic post space before FRC Postec placement using three different adhesive systems (self-etching- Panavia F; total-etching- Excite DSC + Variolink II e self adhesive - RelyX Unicem Aplicap). According to ISO-TS 11405, sectioned at the CEJ, human dental single roots were endodontically treated with rotatory instruments and filled with gutta-percha points and sealer. Were used at 40 J/cm2 an axial Z4 laser tip (400 m diameter) and a radial (side firing) RFT4 laser tip (415 m diameter). This density of energy was experimentally determinated observing morphological changes in SEM images due to an increase range in the energy applied to dentinal root canal surface. At the length between 32 and 49 J/cm2 most of the intracanal dentinal tubules were open. The temperature increase was within the biological safe suggesting a feasible clinical use. Each root canal was irradiated five times with helicoidal movements from apical to cervical, with 20 seconds interval. FRC Postec were immediately cemented and randomly divided in nine groups (n=10). Each root canal was cut in six discs for push out test, were the maximum failure load was obtained and the bond strength was calculated as a function of post bonded area. The bond strength for the irradiated groups was superior among all control groups. The evaluation of bond strength among root region (cervical, middle and apical) was performed and differences were observed. The self-adhesive (RelyX Unicem Aplicap) system was noted superior among all irradiated groups and all regions. Chemical changes were analyzed by FTIR due to dental root portion and dentinal tubules orientation to laser beam direction. The FTIR spectra obtained indicated changes due to tubules orientation and root canal portion irradiated such as the proportion among the compositional ratio without causing chemical changes. These compositional ratio alterations may affect the bond strength results. The irradiation with Er,Cr:YSGG laser on dentinal walls of a prosthetic post space preparation before the post cementation, as suggested in this study, may increase the bond strength between the post and root canal dentin depending upon the luting cement that is used.
76

Influência da contaminação com sangue e de diferentes agentes de limpeza na adesão de um sistema autocondicionante aos tecidos dentais / Blood contamination and cleaning substances influence on adhesion

Arlene Tachibana 04 August 2008 (has links)
A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24 horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos os experimentos, inicialmente foram realizados os testes em esmalte e em seguida os dentes foram desgastados para realização dos testes em dentina, nas mesmas condições. Após a realização dos testes de microcisalhamento, observamos os tipos de fraturas ocorridas e as médias dos valores de resistência adesiva obtidos por cada metade de dente calculada. Os resultados obtidos nos permitiram concluir que o sangue heparinizado pode ser armazenado para posterior utilização por até 7 dias sem perder suas características de contaminante. A escolha relativa ao tipo de sangue que se deve utilizar - sangue fresco ou sangue heparinizado fica a critério do pesquisador e suas conveniências experimentais. Todas as substâncias testadas como agente de limpeza (líquido de Dakin, Tergentol e água oxigenada) na remoção do contaminante sobre esmalte e dentina foram eficientes para restabelecer os valores de resistência de união do sistema adesivo autocondicionante de passo único. Adicionalmente, a simples aplicação do jato de água sobre a superfície de esmalte e dentina contaminada é suficiente para a recuperação dos valores de resistência adesiva. / Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakins solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin.
77

Análise morfológica e da resistência adesiva dos tecidos dentais duros irradiados com lasers de pulsos ultracurtos / Evaluation of dental hard tissues irradiated with ultra-short pulsed lasers. Influence on surface morphology and microtensile bond strength

Marina Stella Bello Silva 16 September 2010 (has links)
O desenvolvimento da Odontologia Restauradora culminou com a era das restaurações estéticas adesivas e da intervenção minimamente invasiva, para as quais técnicas inovadoras e materiais de última geração vêm sendo constantemente introduzidos. As técnicas conservadoras visam não somente a remoção do substrato dental cariado, mas também o preparo das paredes da cavidade para a realização da restauração adesiva. Este estudo visou avaliar a possibilidade de introdução dos lasers de pulsos ultracurtos na Odontologia Restauradora, com o intuito de suprir os requisitos básicos para a realização de uma restauração conservadora adequada. A intenção foi de manter os benefícios já conhecidos relacionados à remoção seletiva de cárie com os lasers de alta potência, bem como superar as desvantagens relacionadas às fontes lasers atualmente disponíveis para este fim, como aumento excessivo de temperatura e adesão prejudicada da superfície irradiada à resina composta. Para a melhor avaliação da interação entre os lasers de pulsos ultracurtos e o substrato dental, os experimentos foram realizados em três fases. A Fase 1 visou avaliar o efeito de diferentes comprimentos de onda (355 nm, 532 nm, 1045 nm e 1064 nm), durações de pulso (pico e femtossegundos) e protocolos de irradiação (velocidade de escaneamento da superfície, espessura do espécime, método de refrigeração e taxa de repetição de pulso) em esmalte e dentina. Para a Fase 2, os parâmetros de irradiação que apresentaram resultados mais favoráveis na Fase 1 foram analisados para relacionar o aumento de temperatura com a taxa de ablação e a eficiência de ablação para cada parâmetro. A Fase 3 teve como objetivo analisar a interface adesiva e os valores de microtração da dentina irradiada com os parâmetros selecionados e estudados na Fase 2, utilizando sistemas adesivos do tipo condicione e lave e autocondicionante com diferentes protocolos de adesão (Clearfil SE Bond com e sem Primer, Adper Single Bond com e sem condicionamento ácido). Os resultados obtidos na Fase 1 indicam que a dentina e o esmalte irradiados com lasers de femtossegundos de 1045 nm e picossegundos de 1064 nm apresentam superfície rugosa livre de carbonização. Os protocolos de irradiação selecionados mostram que a irradiação deve ser conduzida com maior velocidade de escaneamento da superfície, e não há necessidade de refrigeração durante a irradiação. Todos os parâmetros utilizados promoveram ablação seletiva do substrato dental, e apresentaram maior taxa de ablação para dentina que para esmalte. A Fase 2 permitiu observar que todos os parâmetros de irradiação selecionados não provocaram aumento de temperatura maior que 6,1 ºC para esmalte e 4,6 ºC para dentina, quando o aumento de temperatura foi aferido no lado oposto ao irradiado, em espécimes de 1 mm de espessura e sem refrigeração. Exceção foi observada para a maior potência do laser de picossegundos, para a qual a temperatura aumentou até 12 ºC em esmalte e 15 ºC em dentina. Os valores obtidos no ensaio de microtração variaram de acordo com os parâmetros de irradiação e o sistema adesivo. A adesão à dentina irradiada com lasers de pulsos ultracurtos apresentou valores de resistência adesiva semelhantes ou significantemente maiores que os obtidos nos grupos controle, para todos os parâmetros de irradiação selecionados. Os resultados obtidos neste estudo indicam que os lasers de pulsos ultracurtos apresentaram resultados favoráveis para o preparo cavitário em esmalte e dentina em relação à morfologia produzida na superfície e ao aumento de temperatura provocado durante a irradiação. A resistência adesiva à dentina irradiada foi semelhante, ou mesmo significantemente maior que a obtida nos grupos controle. Portanto, os lasers de pulsos ultracurtos são considerados uma técnica promissora para a realização de intervenção minimamente invasiva com lasers de alta potência. / The development of restorative dentistry has reached the era of esthetic adhesive restorations and minimally invasive approach, for which innovative techniques and advanced materials are constantly introduced. Conservative techniques aim not only to remove carious dental substrate, but also to prepare cavity surfaces for adhesive restoration. The main objective of this study was to evaluate the possibility of introducing ultra-short pulsed lasers in Restorative Dentistry, in attempt to fulfill the basic requirements of adequate conservative restoration, by maintaining the well-known benefits of lasers for caries removal, but also overcoming disadvantages related to current laser sources available for this purpose, such as temperature increase and damaged adhesion to resin composite. In order to better evaluate the interaction between ultra-short pulsed lasers and dental substrates, experimental procedures were divided in three phases. Phase 1 aimed to evaluate the effect of different wavelengths (355 nm, 532 nm, 1,045 nm, and 1,064 nm), pulse durations (pico and femtoseconds) and irradiation protocols (surface scanning speed, sample thickness, cooling method, pulse repetition rate) on enamel and dentin. For Phase 2, laser parameters with most favorable results in Phase 1 were evaluated to relate temperature increase to ablation rate or ablation efficiency. Phase 3 aimed to analyze adhesive interface and microtensile bond strength to dentin irradiated with the selected parameters by using etch-and-rinse and self-etch adhesive systems with different bonding protocols (Clearfil SE Bond with and without Primer, Adper Single Bond with and without acid etching). The results of Phase 1 indicate that dentin and enamel irradiated with 1,045-nm fs-laser and 1,064-nm ps-laser present a rough surface without carbonization. Irradiation should be conducted with higher scanning speed, and no additional cooling during irradiation was necessary. All parameters provided selective tissue ablation, with higher ablations rate for dentin than enamel. Phase 2 indicated that all parameters tested provoked temperature increase of up to 6.1 ºC for enamel and 4.6 ºC for dentin, when temperature increase was measured at the back side of 1-mm thick samples without cooling during irradiation, except for higher power for ps-laser, for which temperature increased up to 12 ºC for enamel and 15 ºC for dentin. Microtensile bond strength values varied according to laser parameters and adhesive systems used. Adhesion to dentin irradiated with ultra-short pulsed lasers resulted in similar or significantly higher bond strength values than control groups, for all laser parameters analyzed. Based on the results of this study, ultra-short pulsed lasers presented favorable results for cavity preparation in dentin and enamel regarding surface morphology and temperature increase. Adhesion to irradiated dentin was either similar or superior to traditional techniques. Thus, ultra-short pulsed lasers are considered a promising technique for the promotion of laser-supported minimally invasive approach.

Page generated in 0.0501 seconds