• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 1
  • Tagged with
  • 77
  • 55
  • 50
  • 48
  • 25
  • 19
  • 19
  • 19
  • 17
  • 16
  • 16
  • 15
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Qualidade de vida e capacidade funcional de pacientes com capsulite adesiva submetidos a bloqueios do nervo supraescapular / Quality of life and functional capacity of patients with adhesive capsulitis submitted to suprascapular nerve blocks

Fernandes, Marcos Rassi 27 June 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-10-09T17:06:03Z No. of bitstreams: 2 Tese - Marcos Rassi Fernandes - 2013.pdf: 3024550 bytes, checksum: c4d90a110a9b3b2805efd4361d807ff2 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-10-09T17:12:33Z (GMT) No. of bitstreams: 2 Tese - Marcos Rassi Fernandes - 2013.pdf: 3024550 bytes, checksum: c4d90a110a9b3b2805efd4361d807ff2 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-10-09T17:12:33Z (GMT). No. of bitstreams: 2 Tese - Marcos Rassi Fernandes - 2013.pdf: 3024550 bytes, checksum: c4d90a110a9b3b2805efd4361d807ff2 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-06-27 / Introduction: The simultaneous assessment of quality of life and functional capacity from the patient's self perception with adhesive capsulitis may contribute to the improvement of health care of this population. Objectives: To describe the techniques and clinical indications of suprascapular nerve block, as well as their complications, based on literature data; to assess the quality of life and functional capacity of patients with adhesive capsulitis at the beginning and end of treatment with blocks and to analyze the factors associated with satisfactory quality of life and better functional capacity. Methods: Prospective clinical study in adults and elderly patients with adhesive capsulitis submitted to weekly treatment with suprascapular nerve blocks, users of a private orthopaedic hospital, located in the city of Goiânia-GO, in the period of august 2010 to february 2012. Quality of life was assessed by the WHOQOL-BREF and functional capacity by DASH at the beginning and end of treatment. The Constant score greater than or equal to 55 points was used for the end of the blocks and the Wilcoxon test to compare the initials and finals scores of the WHOQOL-BREF and DASH. Multiple regression analysis of Poisson was carried out using satisfactory quality of life and better functional capacity as outcomes. Significance level of 5%. Results: Forty-three patients with a mean age of 54,7 years were evaluated. Better scores of quality of life and functional capacity were obtained at the end of treatment, when compared to the initials scores. Patients with age greater than 50 years old were associated with higher scores of quality of life in the physical and psychological WHOQOL-BREF domains and those with better educational level in the physical and environmental domains. Age greater than 50 years old and higher schooling were also associated with better functional capacity of the affected shoulder. Conclusions: There are several techniques and clinical indications for the performance of the suprascapular nerve block. Although rare, complications may occur. Quality of life and shoulder functional capacity of patients with adhesive capsulitis improved at the end of the treatment with suprascapular nerve blocks, being influenced by the higher age and better educational level. / Introdução: A avaliação simultânea da qualidade de vida e da capacidade funcional, a partir da percepção dos próprios pacientes portadores de capsulite adesiva, pode contribuir para a melhoria da atenção à saúde dessa população. Objetivos: Descrever as técnicas e indicações clínicas do bloqueio do nervo supraescapular, bem como suas complicações, a partir de dados da literatura; avaliar a qualidade de vida e a capacidade funcional de pacientes com capsulite adesiva no início e no final do tratamento com bloqueios e analisar os fatores associados à qualidade de vida satisfatória e à melhor capacidade funcional. Métodos: Estudo clínico prospectivo em pacientes adultos e idosos com capsulite adesiva submetidos a tratamento semanal com bloqueios do nervo supraescapular, usuários de um hospital ortopédico privado, localizado na cidade de Goiânia-GO, no período de agosto de 2010 a fevereiro de 2012. A qualidade de vida foi avaliada pelo WHOQOL-BREF e a capacidade funcional pelo DASH, tanto no início quanto no final do tratamento. O escore de Constant maior ou igual a 55 pontos foi utilizado para o término dos bloqueios e o teste de Wilcoxon para comparar os escores iniciais e finais do WHOQOL-BREF e DASH. Foi realizada análise de regressão multivariada de Poisson, utilizando como desfechos a qualidade de vida satisfatória e a melhor capacidade funcional. Nível de significância de 5%. Resultados: Foram avaliados 43 pacientes, com idade média de 54,7 anos. Foram obtidos melhores escores de qualidade de vida e capacidade funcional no final do tratamento, quando comparados aos escores iniciais. Pacientes com idade maior que 50 anos foram associados a escores mais elevados de qualidade de vida nos domínios físico e psicológico do WHOQOL-BREF e aqueles com melhor nível educacional nos domínios físico e ambiental. Idade maior que 50 anos e maior escolaridade também foram associados à melhor capacidade funcional do ombro acometido. Conclusões: Existem diversas técnicas e indicações clínicas para a realização do bloqueio do nervo supraescapular. Apesar de raras, complicações podem ocorrer. A qualidade de vida e a capacidade funcional do ombro dos pacientes com capsulite adesiva melhoraram no final do tratamento com bloqueios do nervo supraescapular, sendo influenciadas pela maior idade e melhor nível educacional.
52

AvaliaÃÃo in vitro do efeito da desnaturaÃÃo tÃrmica do colÃgeno e do tratamento com clorexidina da dentina na resistÃncia adesiva / In vitro evaluation of the effect of thermal collagen denaturation and chlorhexidine application on resin-dentin bond strength

MarÃlia Mota Silva 17 December 2010 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Os sistemas adesivos atuais promovem uma imediata e eficaz resistÃncia de uniÃo com os substratos dentais. Entretanto, ao longo do tempo, pode haver uma degradaÃÃo desse processo, influenciando negativamente na manutenÃÃo dos valores de resistÃncia. O digluconato de clorexidina (CHX) tem seu emprego difundido na odontologia como um agente antimicrobiano, entretanto alÃm da aÃÃo desinfetante, ele tem sido estudado para manter a estabilidade da resistÃncia adesiva. Por outro lado, alguns autores tÃm considerado a hipÃtese de que as fibras de colÃgeno podem nÃo ser tÃo importantes para a uniÃo micromecÃnica entre dentina e resina composta, jà que existem evidÃncias de que o prÃprio condicionamento com Ãcido fosfÃrico pode levar a uma mudanÃa na estrutura molecular das fibras, podendo desnaturÃ-las. Este estudo tem por objetivo avaliar a resistÃncia adesiva entre sistema adesivo e dentina, utilizando um sistema adesivo convencional, em funÃÃo do tempo e dos tratamentos que serÃo empregados: desnaturaÃÃo das fibras de colÃgeno e aplicaÃÃo do CHX previamente ao sistema adesivo. Para isto foram utilizados 30 terceiros molares humanos que tiveram a dentina superficial exposta, seguido do condicionamento com Ãcido fosfÃrico e divididos em trÃs grupos. O grupo controle e grupo CHX foram imersos em Ãgua a 37ÂC durante 10 minutos e o grupo desnaturaÃÃo em Ãgua a 50ÂC durante 10 minutos. O grupo controle e desnaturaÃÃo foram tratados de acordo com as instruÃÃes dos fabricantes e o grupo CHX com clorexidina a 2% apÃs o condicionamento Ãcido e antes da aplicaÃÃo do sistema adesivo. Os espÃcimes ficaram armazenados em Ãgua destilada a 37ÂC e, posteriormente cortados, obtendo-se espÃcimes em forma de palitos que foram testados nos perÃodos de 24h e 6 meses. Os espÃcimes foram tracionados atà a ruptura da uniÃo a uma velocidade de 1mm/min e sua forÃa de uniÃo mensurada. O modo de fratura foi observado utilizando microscopia Ãtica com 40X de aumento. Os dados da resistÃncia de uniÃo foram estatisticamente analisados usando os testes de Kolmogorov-Smirnov, Levine, F de Snyder, Turkey e T de Student. Os resultados da microtraÃÃo mostraram que o grupo controle, o grupo tratado com CHX e o grupo desnaturado, tiveram uma reduÃÃo significativa da resistÃncia (p < 0,05) apÃs 6 meses. Entretanto o percentual dessa reduÃÃo do grupo CHX foi de apenas 16,08%, enquanto o grupo controle teve 27,27% e o grupo desnaturado 28,58%. Observa-se uma queda da resistÃncia menor no grupo CHX, quando comparado aos outros 2 grupos. A degradaÃÃo da camada hÃbrida foi significativa no perÃodo de 6 meses nos dois tratamentos utilizados, embora o grupo CHX tenha apresentado uma melhor performance. A desnaturaÃÃo tÃrmica das fibras de colÃgeno nÃo influenciou a resistÃncia adesiva. / The current adhesive systems promote an immediate and effective bond strength to dental substrates, however, over time, there may be a degradation of that process, impacting negatively on the maintenance of resistance values. Chlorhexidine digluconate (CHX) its widespread use in dentistry as an antimicrobial agent, however beyond acting disinfectant, it has been studied to maintain the stability of the bond strength. On the other hand, some authors have considered the hypothesis that the collagen fibers may not be as important for micromechanical union between dentin and composite resin, since there is evidence that the phosphoric acid itself can lead to a change in the structure molecular fibers, which can denature them. The aim of this study was evaluate the effect of thermal collagen denaturation and 2% chlorhexidine (CHX) application on resin-dentin bond strength in teeth restored with conventional adhesive. The study sample consisted of 30 human third molars, of which the dentin was exposed followed by phosphoric acid etching. The specimens were distributed in three main groups (CHX, thermal denaturation and control). Thermal denaturation consisted of immersion in water at 50ÂC for 10 minutes. Control and thermal denaturation groups was costumarily restored and CHX group was treated with 2% chlorhexidine after acid etching and before bonding. The specimens were stored in distilled water at 37ÂC for 24 hours or 6 months and then sectioned into sticks which were submitted to tensile bond testing at a crosshead speed of 1mm/min. The bond failure mode was observed by microscopy (40X). The results of the tensile bond test were expressed in MPa and analyzed with the tests of Kolmogorov-Smirnov, Levine, Snyder F, Tukey and Student t. In all groups bond strength decreased significantly over 6 months (p<0.05), but the loss of bond strength was smaller in the CHX group (16,08%) than in the control group (27,27%) and the thermal denaturation group (28,58%). The hybrid layer was extensively degraded over a period of 6 months. However, treatment with CHX reduced loss of bond strength in relation to controls. Thermal denaturation of collagen fibrils did not affect bond strength.
53

Avaliação da resisténcia de união e caracterização da camada híbrida formada por adesivos experimentais a base de metacrilato hidrófobo ou solvatado em 10% e 30% de etanol, aplicados sobre dentina saturada com etanol em um estudo de longevi / Evaluation of bond strength and characterization of hybrid layer produced by an experimental adhesive based on hydrophobic methacrylate or dissolved in 10% and 30% ethanol, applied to ethanol-saturated dentin in a longevity study

Andre Guaraci De Vito de Moraes 20 May 2009 (has links)
A longevidade da interface adesiva é afetada pelos efeitos da degradação hidrolítica, cuja ocorrência está associada ao alto conteúdo de água presente no tecido dentinário. A hibridização da dentina com monômeros hidrófobos em um substrato isento de água poderia fazer com que a resistência de união dessas interfaces se mantivesse estável por um período de tempo prolongado. O objetivo deste estudo foi avaliar a resistência de união, através do teste de microtração, da interface adesiva em dentina saturada com etanol, sobre a qual se fez o uso de um adesivo hidrófobo, além de caracterizar a morfologia desta interface. Vinte e oito dentes molares foram cortados para que um flat de dentina do terço médio fosse obtido. Foram estudados quatro grupos experimentais: Grupo controle (Scotchbond MultiUso, 3M ESPE), cuja dentina foi saturada com água, grupo experimental 1, cuja dentina saturada com etanol foi hibridizada com o adesivo hidrófobo puro do sistema Scotchbond e grupos experimentais 2 e 3, cuja dentina saturada com etanol recebeu primers hidrofóbicos dissolvidos em etanol 10% e 30% respectivamente. Após a hibridização da dentina, os dentes foram restaurados de forma incremental com resina composta (Filtek Z350, 3M ESPE). As resistências adesivas imediata (24 horas) e tardia (6 meses) foram avaliadas por -tração (0.5 mm/min) de palitos obtidos por cortes perpendiculares à interface adesiva, com área de seção transversal de 1 mm2. O meio de armazenagem dos palitos foi saliva artificial a 37°C. Amostras dos palitos foram preparadas para caracterização da interface adesiva e avaliação do modo de fratura em microscopia eletrônica de varredura. Os dados foram submetidos à análise de variância de dois fatores, Técnica Adesiva e Tempo de Armazenamento, sendo este último vinculado. Os resultados encontrados não mostraram diferença estatística para todos os grupos estudados após 6 meses de armazenamento quando comparados com os dados obtidos de forma imediata (24 horas). Também não foram encontradas diferenças entre os grupos quando avaliados em 24 horas e em 6 meses separadamente. A camada híbrida formada em dentina saturada por etanol apresentou características similares, em relação à morfologia e dimensão, àquela formada pela técnica convencional. A técnica de substituição de água por etanol produziu interfaces tão resistentes quanto à técnica úmida convencional, pelo menos nos primeiros seis meses. / The longevity of an adhesive interface is affected by the effects of hydrolytic degradation, which is associated with high water content in the dentin tissue. The hybridization of dentin with hydrophobic monomers in a water-free substrate could make the bond strength of these interfaces remain stable for an extended period of time. The aim of this study was to evaluate the bond strength of the adhesive interface in ethanol-saturated dentin using a microtensile test, on which a hydrophobic adhesive was used, and also to characterize the morphology of this interface. Twenty-eight molar teeth were cut to a flat middle third of the dentin was obtained. We studied four experimental groups: control group (Scotchbond MultiPurpose, 3M ESPE), whose dentin was saturated with water; experimental group 1, whose dentin saturated with ethanol was hybridized with the pure hydrophobic adhesive from Scotchbond adhesive system and experimental groups 2 and 3, whose dentin saturated with ethanol received hydrophobic primers dissolved in ethanol 10% and 30%, respectively. After dentin hybridization, teeth were restored with the incremental technique with composite resin (Filtek Z350, 3M ESPE). The immediate (24 hours) and late (6 months) adhesive resistance was determined by - tensile (0.5 mm / min) of \"sticks\" obtained by perpendicular cuts on the adhesive interface, with cross section area of 1 mm2. The sticks storage medium was artificial saliva at 37 °C. Interface samples were prepared to characterize the adhesive interface and to assess the failure mode by scanning electron microscopy. The data were submitted to two factors analysis of variance, adhesive technique and storage time, the latter being dependent. The results showed no statistical differences for all groups after 6 months of storage when compared to data obtained from the immediate group (24 hours). Also, no differences were found between groups evaluated at 24 hours and 6 months separately. The hybrid layer formed in ethanolsaturated dentin had similar characteristics considering the morphology and size formed by conventional technique. The technique of water replacement for ethanol produced interfaces as strong as the conventional wet technique, at least in the first six months.
54

"Influência do método de remoção de cárie na resistência adesiva de um sistema autocondicionante" / Microtensile bond strength of self-etching adhesives to caries-affected dentine

Tachibana, Arlene 10 June 2005 (has links)
Novos métodos de remoção do tecido cariado tem sido propostos, entre eles a utilização de lasers, abrasão a ar e químico-mecânico. Este trabalho teve o objetivo de avaliar a influência de diferentes métodos de remoção de cárie na resistência de união de um sistema adesivo autocondicionante. Cinquenta molares humanos cariados extraídos foram desgastados para expor uma superfície plana onde a lesão de cárie se encontrava rodeada por dentina hígida. Os dentes foram divididos em 05 grupos (n=10), com um total de 50 dados, de acordo com o método de remoção do tecido cariado, como segue: G1 - sem remoção; G2 - remoção com lixa; G3 – broca de aço esférica em baixa rotação; G4 - laser de Er, Cr: YSGG e G5 - Carisolv. Procedimentos adesivos foram realizados com o sistema autocondicionante (Clearfil SE Bond – Kuraray – Japão), de acordo com as instruções do fabricante. Um cilíndro de resina composta (Z250- 3M do Brasil) foi construído sobre a superfície com o sistema adesivo e estocados em água (24 horas a 37 0 C). Os corpos de prova foram seccionados verticalmente para obtenção de fatias e em seguida confeccionadas ampulhetas em dentina infectada, afetada e sadia, com área aproximada de 1mm 2. As ampulhetas foram montadas em dispositivos de micro-tração e ensaiados na máquina de teste (Mini-Instron) com velocidade de 0,5mm/min. Os resultados obtidos mostraram que existem diferenças estatisticamente significantes entre os substratos sadio e infectado para o grupo G1e sadio e afetado para os grupos G2, G3 e G5. Em dentina sadia, o método utilizado em G3 resultou em valores de adesão superiores com relação a G4 e G2 foi estatisticamente superior com relação a todos os grupos. Os métodos de remoção de dentina infectada utilizados em G2 e G3 resultaram em valores de adesão superiores com relação a G1(dentina infectada). Desta forma podemos concluir que: o tipo de substrato influencia significativamente na resistência adesiva do sistema autocondicionante testado. A adesão à dentina sadia é mais efetiva que à dentina infectada (G1) e à dentina afetada obtida após remoção do tecido infectado com lixa (G2), broca (G3) e Carisolv (G5). Entretanto, para o laser de Er,Cr:YSGG (G4) não houve evidência amostral que sugerisse maior efetividade na adesão da dentina sadia com relação à dentina afetada. A adesão em dentina sadia mostrou-se mais efetiva quando esta foi instrumentada com lixa. Porém, trata-se de um recurso laboratorial de padronização dos espécimes. A utilização da broca de aço resultou em uma superfície mais favorável a adesão, quando comparada à obtida após irradiação com laser de Er, Cr: YSGG, em dentina sadia. A adesão em dentina infectada é pobre, ficando ressaltada a necessidade da remoção deste tipo de dentina, preferencialmente com lixa ou broca, previamente a adesão com sistema autocondicionante. Para os demais métodos de remoção da dentina infectada testados, não houve evidência amostral para se detectar a existência de diferenças significantes na resistência adesiva em dentina afetada. / New methods for carious dentine removal have been proposed, such as, lasers and chemo-mechanical. This in vitro study aimed to evaluate the influence of caries removal methods (steel burs, Er, Cr: YSGG laser and Carisolv) on microtensile bond strength of self-etching adhesive systems. 50 extracted carious human molars were ground to expose flat surfaces where caries lesion was surrounded by normal dentine. Teeth were divided into 5 groups (n=10), with 50 original data, according to the removal method used: G1 - no removal; G2 - abrasive paper, G3 - steel burs; G4 – Er, Cr: YSGG laser (79, 61 J/cm 2 ) and G5 – Carisolv. Surfaces were bonded with Clearfil SE Bond, according to manufacturers’ instructions. A crown was built up using composite resin (Z250- 3M Brasil). After storage in water (24 h, 37 0 C), teeth were vertically serially sectioned into slices and trimmed into an hourglass shape with about of 1mm 2 area at the adhesion interface, that contained either infected, caries affected and normal dentine. Samples were tested in tension in a Instron machine at 0,5mm/min. Results showed that there is a significant difference between tested groups (p< 0.005). Significantly lower results were found for caries infected dentin when compared to normal dentin values (G1). A significant difference was also found when caries affected and normal dentin were compared (G2, G3, G5). In normal dentin, G2 showed better bond strenght than another groups and G4 showed lower results than G3. G2 and G3 caries infected dentin removal methods showed better bond strength than the other groups when compared with G1 (caries infected dentin). The results indicated that: bond strength of a self-etching system to normal dentin was better than to caries infected (G1) and caries affected dentin after the use of abrasive paper (G2), round steel bur (G3) and Carisolv (G4). However, there was no difference between caries affected and normal dentin after the use of ErCr:YSGG laser (G4); abrasive paper is a laboratorial method to create smear layer and it was responsable for the best bond strength to normal dentin. The usage of Er, Cr: YSGG laser negatively altered adhesion of self-etching system on normal dentin when compared with round steel bur; infected dentin is not an adequate substrate for adhesion. Abrasive paper and round steel bur are the best caries infected dentin removal methods. There were no difference in bond strength to caries affected dentin when the other methods were used.
55

Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laser

Ramos, Thaysa Monteiro 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
56

Efeito da contaminação por saliva humana na interface adesiva: resistência de união, análise de camada híbrida e conversão de sistemas adesivos / Effect of human saliva contamination on adhesive interface: bond strength, hybrid layer analysis and conversion of adhesive systems

Villavicencio Espinoza, Carlos Andres 03 July 2017 (has links)
Este estudo teve como objetivo analisar o efeito da contaminação por saliva humana na resistência de união (RU) da interface adesiva em dentina por microtração, nas características morfológicas da camada híbrida (CH) em microscopia confocal e no grau de conversão (GC) de 2 sistemas adesivos: Adper Single bond 2 (SB) e Single Bond® Universal (SU). Cento e oitenta dentes terceiros humanos hígidos foram divididos em 12 grupos (n=10), de acordo com o sistema adesivo utilizado, a presença de saliva e o tempo de armazenagem. Após o procedimento adesivo e aplicação da resina composta Filtek Z250, os dentes foram mantidos em água destilada em estufa a 37°C por 48 horas, 6 meses ou 12 meses antes de serem seccionados em palitos (0,8mm x 0,8mm, aproximadamente) para serem levados à máquina de ensaios universal Instron para os testes de microtração. Para à análise da interface adesiva em microscopia confocal de varredura a laser para verificação e mensuração de alterações internas na interface foram utilizados 60 dentes divididos em 6 grupos (n=10) de acordo com os tempos de 48 horas, 6 meses, e 12 meses respectivamente, empregando os sistemas adesivos (SB) e (SU). O efeito da presença de saliva também foi avaliado pelo grau de conversão dos adesivos, empregando-se espectroscopia de infravermelho transformada de Fourier empregando os sistema adesivos (SB) e (SU) com incorporação de saliva humana na sua composição (n=5) com concentrações 10%, 25% e 50% em vol. Para a comparação das variáveis: RU, (GC), espessura da CH, na presença de saliva e tempo de armazenamento foram utilizados os testes de Análise de Variância a três critérios e de comparações múltiplas de Tukey (p<0,05). Os valores de RU (MPa±dp: 48horas/6meses/1ano) foram: SB (43,53 ±6,0; 40,10±3,4; 38,59±5,4); SalSB (43,09±6,2; 39,86±6,6; 37,255,8); SU (42,98±4,3; 39,30±3,6; 40,44±5,7); Sal SU (44,39±4,2; 42,26±2,5; 38,26±5,7). Os Valores médios da CH (MPa±dp: 48horas/6meses/1ano) foram: SalSB (3,59±0,8; 3,59±1,0; 2,08±1,5). SalSU (1,26±0,5; 1,73±0,8; 1,07±0,3). Os valores de GC (MPa±dp: 10%/25%/50%vol) foram: SB (85,59±3,4; 49,68±12,8; 38,56±11,8); SU (85,52±3,3; 86,27±3,5; 57,82±11,1).Conclui-se, portanto, que a contaminação por saliva humana não interferiu na RU da interface dentina/resina composta após 48 horas, 6 meses e 12 meses. A morfologia da camada hibrida foi alterada pela presença da saliva nos períodos 6 e 12 meses,. O GC dos sistemas adesivos foi afetado pela presença de saliva após a polimerização imediata. Entretanto o fator tempo foi determinante para a deformação da interface dentina/resina para ambos os sistemas adesivos. / The objective of this study was to analyze the effect of human saliva contamination on bond strength of the dentin/adhesive interface, morphology of the hybrid layer by confocal microscopy and SEM analysis and degree of conversion of 2 adhesive systems: Adper Single bond 2 (SB) and Single Bond® Universal ( SU). One hundred and eighty healthy human third teeth were divided into 12 groups (n = 10), according to the adhesive system used, the presence of saliva and the storage time. After the adhesive procedure and placement of resin composite (Filtek Z250), the teeth were stored in distilled waterat 37 ° C for 48 hours, 6 months or 12 months before being cut into sticks (0.8mm x 0.8mm, approximately) to the microtensile strength tests. For the analysis of the adhesive interface in confocal microscopy of laser scanning for verification and measurement of internal interface changes, 60 teeth were used divided into 6 groups (n = 10) according to the storage time: 48 hours, 6 months, and 12 monthsand (SB) and (SU). The effect of the presence of saliva was also evaluated by the degree of conversion of the adhesives using Fourier transform infrared spectroscopy employing adhesive (SB) and (SU) systems incorporating human saliva in its composition (n = 5) with 10%, 25% and 50% vol. For the comparison of the variables: bond strength, degree of conversion, and hybrid layer thickness in the presence of saliva and storage time, the three criteria Variance Analysis and Tukey multiple comparisons tests (p <0.05) were used. The values of bond strength (MPa ± dp: 48hours / 6meses / year) were: SB (43.53 ± 6.0, 40.10 ± 3.4, 38.59 ± 5.4); SalSB (43.09 ± 6.2, 39.86 ± 6.6, 37.255.8); SU (42.98 ± 4.3, 39.30 ± 3.6, 40.44 ± 5.7); SU salt (44.39 ± 4.2, 42.26 ± 2.5, 38.26 ± 5.7). The mean values of hybrid layer thickness (MPa ± dp: 48hours / 6meses / year) were: SalSB (3.59 ± 0.8, 3.59 ± 1.0, 2.08 ± 1.5). SalSU (1.26 ± 0.5, 1.73 ± 0.8, 1.07 ± 0.3). The values of degree of conversion (MPa ± dp: 10% / 25% / 50% vol) were: SB (85.59 ± 3.4, 49.68 ± 12.8, 38.56 ± 11.8); (85.52 ± 3.3, 86.27 ± 3.5, 57.82 ± 11.1). It was therefore concluded that human saliva contamination did not interfere on bond strength of the dentin/adhesive interface after 48 hours, 6 months and 12 months. The morphology of the hybrid layer was altered by the presence of saliva after 6 and 12 months. The degree of conversion of adhesive systems was affected by the presence of saliva immediately after polymerization. However, the time factor was determinant for the dentine/resin interface deformation for both adhesive systems.
57

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

Cardenas, José Edgar Valdivia 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.
58

Efeito do retardamento da polimerização da base de cimento de ionômero de vidro modificado por resina na resistência adesiva em restaurações de resina composta / Effect of delaying photoativation of resin modified glass-ionomer cement used as a liner on the bond strength of composite resin restorations

Casas Apayco, Leslie Caroll 22 April 2009 (has links)
Durante o processo inicial da reação de presa, o cimento de ionômero de vidro modificado por resina (CIVMR) apresenta baixo módulo de elasticidade, característica importante quando utilizado como base de restaurações com resina composta, por diminuir o estresse de contração de polimerização nas paredes cavitárias. O presente estudo teve como objetivo analisar a influência da técnica de polimerização de uma base CIVMR (VitrebondTM) por resina na interface dente/restauração de resina composta, através de teste de microtração e análise em microscopia confocal. Foram utilizados 30 dentes molares humanos hígidos extraídos, nos quais foram confeccionadas cavidades padronizadas em sua face oclusal (5mm de comprimento x 3mm de largura x 4,5mm profundidade). O sistema adesivo utilizado AdperTM Single Bond 2 foi marcado previamente com Rodamina B (0,16mg/ml), para possibilitar a análise em microscópio confocal. Os dentes foram divididos em 3 grupos: Grupo 1 (controle): base de CIVMR VitrebondTM + fotoativação + sistema adesivo + resina composta FiltekTM Z250; Grupo 2: base de CIVMR VitrebondTM + sistema adesivo + fotoativação por 30 segundos simultânea dos dois materiais + resina composta FiltekTM Z250; Grupo 3: base de CIVMR por resina VitrebondTM + tempo de espera de 60 segundos + fotoativação + sistema adesivo + resina composta FiltekTM Z250. Após a restauração, os dentes permaneceram em água deionizada em estufa a 37 ºC por 24 horas. Em seguida, foram seccionados com disco de diamante em fatias de aproximadamente 0,8mm no sentido vestíbulo-lingual. Uma fatia de cada dente foi separada aleatoriamente para análise da presença de fendas na interface dentina/resina composta em microscopia confocal. As demais fatias foram seccionadas para a confecção de palitos, para os testes de microtração. Os resultados de resistência de união foram submetidos à análise de variância a um critério ANOVA a 5% e teste de qui-quadrado para as variáveis de presença de fendas marginais e tipo de fratura resultante (p<0,05). Não houve diferença estatisticamente significante entre os três grupos (p=0,644) com relação à resistência adesiva e tipo de fratura, predominando a fratura do tipo adesiva para todos os grupos. Quanto à presença de fendas marginais internas, foi evidenciada sua presença nos grupos 2 e 3, sem diferença estatisticamente significante entre os três grupos testados (p=0,082). Conclui-se, portanto, que a técnica de polimerização da base de cimento de ionômero de vidro modificado por resina não influencia na resistência adesiva da interface dente/restauração de resina composta. / During the initial process of setting reaction, the resin-modified glass-ionomer cement (RMGIC) shows low modulus of elasticity, which is an important characteristic when RMGIC is used as a liner in resin composites restorations, because it decreases the polymerization shrinkage stress in cavity walls. The aim of this study was to analyze the influence of polymerization techniques of resin-modified glass-ionomer cement used as a liner on the adhesive interface dentin/resin by microtensile test and confocal microscopic analysis. Standardized occlusal cavity preparations (5mm length x 3mm wide x 4.5mm depth) were prepared in 30 human extracted molars. For the analysis at the confocal microscope, the adhesive system AdperTM Single Bond 2 was previously marked with rodhamine B (0.16mg/ml). The tooth were divided into three groups: Group 1 (control): RMGIC liner VitrebondTM + photoactivation for 30 seconds + adhesive system + resin composite Filtek TM Z250; Group 2: RMGICs liner VitrebondTM + adhesive system + simultaneous photoactivation of both materials + resin composite FiltekTM Z250; Group 3: RMGICs liner VitrebondTM+ 60 seconds delay time + photoativation for 30 seconds + adhesive system + resin composite FiltekTMZ250. Specimens were stored at 37ºC in deionized water for 24 hours. After this period, tooth was sectionated in 0.8mm slices (buco-lingual). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distal) for microtensile test. One-way ANOVA (p<0.05) showed no significant statistical difference among groups 1, 2 and 3 (p=0.644). Quisquare test showed no significant statistical difference of type of fracture (adhesive fracture was predominant) and presence of gap at the interface dentin/resin among groups. (p=0.082). It can be concluded, that polymerization technique of resin-modified glassionomer cement (RMGIC) did not influence bond strength and dentin/resin composite interface.
59

Avaliação das propriedades físicas de resinas compostas restauradoras pré-aquecidas e resinas fluidas com a finalidade de cimentação de facetas cerâmicas / Evaluation of the physical properties of preheated restorative resin composites and fluid resins for ceramic veneer cementation

Almeida, Sandra Barbosa Moraes de 07 December 2016 (has links)
Este estudo teve o objetivo de avaliar as propriedades físicas de resinas compostas restauradoras pré-aquecidas e de resinas fluidas com finalidade de cimentação de facetas de cerâmicas em comparação aos cimentos resinosos. Foram produzidos corpos de prova de duas marcas comerciais 3M ESPE e Ivoclar Vivadent, sendo: duas resinas restauradoras (Filtek Z250XT e Tetric N Ceram) nas condições: temperatura ambiente (RZ e RT), aquecidas à 45°C (RZ45 e RT45), aquecidas à 60°C (RZ60 e RT60); duas resinas fluidas (Filtek Z350 Flow e Tetric N Flow) denominadas FZ e FT e dois cimentos resinosos (Relyx Veneer e Variolink N) denominados CR e CV. Os grupos experimentais foram avaliados quanto à espessura de película por duas metodologias, resistência à flexão biaxial (RFB) e módulo de elasticidade (ME) executados em máquina de ensaio universal (modelo 5565, Instron Corp, Canton MA, EUA), microdureza Knoop feitas em microdurômetro (Shimadzu HMV-2, Tóquio, Japão) e diferença de cor (?E), razão de contraste e opalescência realizadas no espectrofotômetro CM-3770 (Konica Minolta, Japão). Os dados foram avaliados por análise de variância e teste de Tukey (p<0,05). As resinas restauradoras apresentaram películas com espessura maiores que 100 ?m, enquanto as resinas fluidas e os cimentos resinosos apresentaram valores menores que 50 ?m. Os grupos experimentais RZ, RZ45 e RZ60 apresentaram os maiores valores de KHN, RFB e ME. Os grupos RT, RT45, RT60, FT, CV e CR apresentaram os menores valores de RFB e semelhantes entre si. Para a KHN, os grupos RT, RT45, RT60, FZ e CR apresentaram valores intermediários e semelhantes entre si, e superiores aos grupos FT e CV. Os resultados de ?E mostraram valores acima de 2 para todos os grupos experimentais, com exceção do RZ60. Os maiores valores de ?E foram evidenciados nos grupos RT45 e RT60. A razão de contraste foi estatisticamente menor para o grupo CV e os maiores valores de opacidade foram encontrados nos grupos RZ, RZ45 e FZ. A opalescência foi superior nos grupos FZ, CR, FT e CV. Considerando as limitações do presente estudo, concluiu-se que os tratamentos térmicos não alteraram as propriedades mecânicas das resinas restauradoras e não promoveram uma redução da espessura de película que atenda aos requisitos da ISO4049. As resinas fluidas e os cimentos apresentaram espessura de película inferior à 50?m e propriedades mecânicas que atendem à normativa ISO4049. A opalescência maior foi encontrada nos cimentos resinosos e a diferença de cor e razão de contraste apresentaram resposta grupo dependente. / The objectives of this study were to evaluate the physical properties of preheated restorative resin composites and fluid resins with the purpose of cementation of ceramic veneers in comparison to resin cements. Specimens were prepared with two restorative resin composites (Filtek Z250XT and Tetric N Ceram), in the following conditions: room temperature (RZ; RT), heated at 45°C (RZ45; RT45), and heated at 60°C (RZ60; RT60). Two flowable resins (Filtek Z350 Flow and Tetric N Flow) named FZ and FT and two resin cements (Relyx Veneer and Variolink N), called CR and CV, were also used. The experimental groups were evaluated in regards to film thickness with two methodologies; biaxial flexure strength (BFS) and modulus of elasticity (ME) (model 5565, Instron Corp, Canton MA, USA); Knoop microhardness test (KMT) (Shimadzu HMV-2, Tokyo, Japan), color difference (?E), contrast ratio and opalescence test (CM-3770d, Konica Minolta, Japan). Data were assessed by ANOVA and a post-hoc Tukey test (p<0.05). The restorative resins presented film thickness larger than 50?m, whereas the flowable resins and resin cements showed inferior values. The experimental groups RZ, RZ45 and RZ60, revealed greater values of KHN, BFS and ME. The RT, RT45, RT60, FT, CV and CR groups showed lower values for BFS and similar to each other. For KHN the RT, RT45, RT60, FZ and CR groups exposed intermediate and similar values to each other, and superior values to FT and CV groups. Color difference (?E) results demonstrated results superior than 2 for all experimental groups, with the exception of RZ60 group. The greater values of ?E were shown in RT45 and RT60 groups. Contrast ratio was statistically lower for the CV group and the highest values of opacity were verified in RZ, RZ45 and FZ groups. Opalescence was superior in FZ, CR, FT and CV groups. Considering the limitations of this study, the results demonstrated that preheated treatments did not modify the mechanical properties of restorative resin composites and didn\'t reduce film thickness which attend to ISO4049 parameters. Flowable resins and cements obtained film thickness inferior to 50?m and biaxial flexure strength results that are presented by the ISO4049. The greater opalescence was shown in the resin cements, also color difference and contrast ratio revealed results that were group dependent.
60

Avaliação da espessura de cimento e resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida / Assessment of cement thickness and bond strength of circular fiber posts in post space preparations with an ultrasonic tip developed

José Edgar Valdivia Cardenas 30 October 2017 (has links)
Preparos para retentores intra-radiculares mais conservadores evitam desgaste desnecessário da estrutura dentinária, requer menos cimento e podem melhorar a retenção adesiva do pino. Assim o objetivo deste estudo foi avaliar a espessura de cimento ea resistência adesiva de pinos de fibra de vidro cônicos em preparo para retentor intra-radicular realizados com uma ponta ultrassônica desenvolvida. Trinta incisivos laterais superiores foram preparados com limas reciprocantes Wave One Gold (Dentsply Sirona, Ballaigues, Suiça) e aleatoriamente divididos em 2 grupos (n=15) de acordo com a técnica de preparo para pino: grupo US foram preparados com uma ponta ultrassônica desenvolvida, e grupo WP (controle) com a broca recomendada pelo fabricante do pino. Os pinos de fibra de vidro cônicos WhitePost DC 0.5 (FGM, Joinville, SC, Brasil) foram cimentados utilizando cimento resinoso dual nos terços cervical e médio do canal radicular. Isto posto, todos os espécimes foram seccionados transversalmente em três seções (cervical, média e apical do pino) para análise da área de cimento resinoso ao redor do pino que foi calculada através do programa AutoCAD, em seguida, para avaliar a resistência adesiva, o teste de cisalhamento por extrusão foi aplicado através de uma maquina de ensaio universal numa velocidade média de 0.5 mm/min até o deslocamento do conjunto restaurador intra-radicular e o tipo de falha avaliado por estereomicroscopia. A comparação entre grupos e entre terços da área de cimento e resistência adesiva foram analisadas pelo teste t independente e Anova com Tukey; e os tipos de falha entre os grupos por Mann-Whitney, todos com nível de significância de 5%. No grupo ultrassônico foi observado a menor quantidade de cimento (p<0.05) e a resistência adesiva nos diferentes grupos e terços se manifestou maior somente no terço apical do grupo ultrassônico (p<0.05). Falha adesiva entre cimento e dentina foi a mais prevalente do terço cervical e apical do grupo US e cervical de grupo WP. Falha adesiva entre cimento e pino foi a mais prevalente nos demais terços. Conclui-se que o preparo para retentor com a ponta ultrassônica desenvolvida requer menor quantidade de cimento e influencia na melhor resistência de união no terço apical do pino de fibra de vidro. / Conservative post space preparations for intra-radicular retainers prevent unnecessary desgaste of the dentin structure, require less cement and improve bond strength of the post. The aim of this study was to evaluate the influence of resin cement thickness and bond strength of prefabricated glass fiber circular postin post space preparations with an ultrasonic tip developed. Thirtymaxillarylateral incisors were prepared with Wave One Gold reciprocating files (Dentsply Sirona, Ballaigues, Switzerland) and randomly divided into 2 groups (n=15) according to the post preparation technique: gruoup US was prepared with an ultrasonic tip developed and group WP (control) with the drill recommended by the post fabricant. Every glass fiber posts WhitePost DC 0.5 (FGM, Joinville, SC, Brazil) was cemented using dual polymerizing resin cement in the cervical and middle thirdof the root canal. After that, every specimen was sectioned transversally into three sections(cervical, middle and apical of the post) and the resin cement thickness area was calculated with AutoCAD program, the bond strength test was done with an universal testing machineat medium velocity 0.5 mm/min and the failure pattern after the test was analyzed with stereomicroscopy. Datas obtained were analyzed statistically using Student\'s t-Test, ANOVA,andTukey\'s test. The comparison of failure modes between the groups in the different thirds was done using Mann-Whitney test, All of those at a 5% significance. Ultrasonic group presented thinnest layer of cement in all thirds (p<0,05), which also obtained a higher bond strength only in apical third (p<0,05). Adhesive failurebetween cement and dentinwas the most prevalent of the cervical and apical third of G1 and cervical of G2.Adhesive failure between cement and post was the most prevalent in the others thirds. It can be concluded that the postpreparation with the ultrasonic tip developed provides a smaller thickness of resin cement that influenced thebond strength in the apical third of the glass fiber post.

Page generated in 0.089 seconds