• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 32
  • 22
  • 13
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Determinação macro e microelementos em adoçantes dietéticos por ICP OES / Determination macro and microelements in dietetic sweetener by ICP OES

Darilena Monteiro Porfirio 16 June 2004 (has links)
Neste estudo foi determinado o conteúdo de metais em adoçantes dietéticos de mesa, consumidos por um número crescente de pessoas preocupadas em manter a forma física e restringir o nível calórico da dieta havendo ou não recomendação médica. Foram coletadas 26 amostras de adoçantes dietéticos distribuídos no mercado de São Paulo, em uma grande variedade de apresentações, produtos, composições e marcas. Como a composição é dependente da produção, esta análise é indispensável ao controle da qualidade e relevante à saúde do consumidor. A Espectrometria de Emissão Óptica com Fonte de Plasma Indutivamente Acoplado (ICP OES) com vista axial, mostrou-se adequada determinação dos macronutrientes Na, K, Ca, Mg e dos microelementos essenciais Fe, Cu, Zn, Cr, Mn e Se, dos potencialmente tóxicos AI, Ni, As, Cd e Pb em adoçantes sólidos e líquidos, atendendo as exigências da legislação brasileira. Assim, foi realizado um estudo comparativo entre as determinações utilizando as metodologias clássicas de pré-tratamento da amostra, como o resíduo de cinzas, a dissolução ácida com aquecimento por microondas com o procedimento sem tratamento prévio das amostras, visando facilitar a análise, uma vez que esta é a etapa que mais consome tempo e esforços. A determinação simultânea do espectro favoreceu a análise, uma vez que 74 comprimentos de onda puderam ser selecionados sem aumento no tempo ou no custo de análise, auxiliando na seleção de 36 linhas analíticas mais adequadas (livre de interferências) à determinação sem tratamento prévio da amostra. Nenhuma amostra de adoçante excedeu o valor recomendado para o somatório dos contaminantes inorgânicos (Aspartame < 10 &#181;g g-1 e Sacarina < 20 &#181;g g-1). No entanto, 6 marcas de adoçantes em pó excederam o valor limite da legislação para As (1,0 &#181;g g-1), excederam o valor para Cr total (0,1 &#181;g g-1) e 2 marcas de adoçante líquido excederam o valor para Ni (0,1 &#181;g g-1). Mostrando que os adoçantes em pó apresentam (&#8776;5 &#181;g g-1) níveis maiores de metais potencialmente tóxicos que os adoçantes líquidos (&#8776;2,O &#181;g mL-1). / The metal content in artificial sweetener usually consumed by a growing population concerned to keep body shape and to restrict the diet caloric content, by medical recommendation or not, was measured. The samples were 26 artificial sweeteners available at São Paulo\'s market, under different forms, and several suppliers, with various sweetener composition, and brands. Because the composition depends on manufacture factors, this analysis is mandatory for quality control and relevant for the user health. Inductively coupled plasma atomic emission with axial view has demonstrated to be an appropriated technique to determine the macronutrient content, such as Na, K, Ca, Mg and essential microelements such as Fe, Cu, Zn, Cr, Mn and Se, besides the potentially toxic elements such as AI, Ni, As, Cd and Pb in solid and liquid sweeteners in accordance with to the Brazilian regulation. It was also performed a comparative study of the sample preparation methodology, using classical sample pretreatment, such as burning to ashes, and acid dissolution with microwave heating and a procedure without prior sample treatment (dissolution and/or convenient dilution), aiming at facilitating the analysis of dietetic sweetener because this step is the most time and labor consuming. The analysis was simplified using the simultaneous spectra acquisition, once 74 wavelengths were selected without time or cost increase, and helping the identification of 36 appropriate analytical lines (free from interferences) to apply to the samples determination without prior treatment. None sweetener exceeded the recommended value of inorganic contaminant (for aspartame samples the value was below 10 &#181;g g-1 and for saccharine samples that was below 20 &#181;g g-1). However, 6 brands of artificial sweetener in powder exceeded the legislation limit value for As (1.0 &#181;g g-1), and other 7 brands exceeded the Cr recommended maximum value (0.1 &#181;g g-1). Other 2 brands of Iiquid sweetener exceeded the Ni recommended maximum value. Therefore, for ali samples, the artificial sweetener in powder presented higher levels of potentially toxic metais (&#8776;5&#181;g g-1) than those in a Iiquid presentation (&#8776;2.0 &#181;g mL-1).
32

Efeitos do ciclamato de sódio na placenta de ratas: estudo morfométrico.

Matos, Marcelo Alexandre de 24 May 2006 (has links)
Made available in DSpace on 2016-01-26T12:51:10Z (GMT). No. of bitstreams: 1 marceloalexandrematos_dissert.pdf: 295732 bytes, checksum: b602897faf078224a99d93671326e504 (MD5) Previous issue date: 2006-05-24 / Objective: To evaluate the effects of sodium cyclamate on the rat placenta by its administration in the period of embryogenesis. Method: The sodium cyclamate was administered by intraperitoneal route in rats of the treated group at the dose of 60 mg/kg, from the tenth to fourteenth day of gestation, while the equivalent volume of saline solution was given to the control group, by the same route. On the twentieth day of pregnancy, 10 fetuses (5 from each group) were chosen at random for study. The technique of cariometry was utilized for evaluation of nuclear parameters of cells in deciduous and spongy layers, and of chorionic villi in the rat placenta. Results: The weights of treated fetuses and their placentas were less than those of the control group, while umbilical-cord length in the treated group was shorter than that in control fetuses. There were no alterations in the deciduous layer. In the placental spongy layer were found alterations of the following parameters: major diameter, mean diameter, perimeter, area, volume, the volume/area ratio and eccentricity. The altered parameters in chorionic villi were the following: mean diameter, perimeter, area, volume, the volume/area ratio. Conclusions: This study demonstrated placental alteration with the use of cyclamate by the pregnancy rat, and its repercussion in fetal weight and umbilical-cord length. / Objetivo: Avaliar os efeitos do ciclamato de sódio na placenta de ratas com sua administração no período da embriogênese. Método: Foi administrado por via intraperitoneal nas ratas do grupo tratado a dose de 60 mg / Kg de ciclamato de sódio, do décimo ao décimo quarto dia de gestação, e volume equivalente de solução salina no grupo controle, pela mesma via. No vigésimo dia de prenhez, 10 fetos (5 de cada grupo) foram escolhidos ao acaso para estudo. Foi utilizada a técnica de cariometria para avaliação dos parâmetros nucleares das células das camadas decídua, esponjosa e das vilosidades coriônicas da placenta de ratas. Resultados: O peso dos fetos tratados e de suas placentas foi menor que os do grupo controle, assim como o comprimento do cordão umbilical do grupo tratado foi mais curto que o dos fetos controles. Não houveram alterações na camada decídua. Na camada esponjosa placentária ocorreram alterações dos seguintes parâmetros: diâmetro maior, diâmetro médio, perímetro, área, volume, relação volume / área e excentricidade. Os parâmetros alterados nas vilosidades coriônicas foram os seguintes: diâmetro médio, perímetro, área, volume e relação volume / área. Conclusões: Este estudo demonstrou alteração placentária com o uso de ciclamato pela rata grávida, e sua repercussão no peso fetal e comprimento do cordão umbilical

Page generated in 0.0451 seconds