Spelling suggestions: "subject:"cooperação intermittent"" "subject:"consideração intermittent""
11 |
Remoção de carbono e nitrogênio em reator de leito móvel submetido à aeração intermitente / Nitrogen and carbon removal in moving bed reactor operated under intermittent aerationNocko, Lissa Maria 30 May 2008 (has links)
O lançamento de águas residuárias contendo compostos nitrogenados tem um importante impacto sobre a saúde e o meio ambiente, tornando necessária a incorporação de processos de remoção desses compostos nos sistemas de tratamento de águas residuárias. Neste trabalho, foram estudadas as condições de operação para promover a remoção conjunta de nitrogênio e matéria orgânica em reator biológico de leito móvel, contínuo, operado sob aeração intermitente, alimentado com água residuária sintética contendo nitrogênio amoniacal (90 a 110 mg/L) e melaço como matéria orgânica (DQO de 450 a 550 mg/L). Foram utilizados dois reatores em escala de bancada, cada um com dois litros de volume útil, contendo diferentes meios suportes para a imobilização da biomassa: matrizes de espuma de poliuretano e anéis plásticos. Na primeira etapa experimental, o reator contendo anéis plásticos apresentou eficiências de remoção de nitrogênio muito baixas. Na segunda etapa, trocou-se o material suporte por matrizes de espuma de poliuretano inoculadas com lodo aeróbio de estação de tratamento de águas residuárias. A partir de então, trabalhou-se com dois reatores de mesma configuração, exceto pelas origens, idades e características dos lodos de inóculo. Inicialmente, a alimentação foi realizada utilizando-se apenas os micronutrientes contidos no melaço. Posteriormente, a composição da água residuária foi alterada, introduzindo-se solução de micronutrientes, pois se concluiu que a instabilidade no processo de nitrificação devia-se ao fato de o melaço comercial apresentar deficiências nutricionais. Como resultado, em condições de estabilidade operacional, foram obtidas eficiências de remoção de DQO superiores a 85%, oxidação total do nitrogênio amoniacal e eficiências de remoção de nitrogênio de aproximadamente 55%. Variações posteriores nas condições de operação, como o aumento do período anóxico (de 1h para 1h15min) e redução do tempo de detenção hidráulica (para valores inferiores a 12 horas), resultaram em melhora no desempenho dos reatores. Os resultados obtidos permitem admitir que as melhores condições de operação não foram atingidas durante o experimento, abrindo a possibilidade para a otimização do processo em pesquisas futuras. Constatou-se que o desenvolvimento das populações microbianas imobilizadas no meio suporte foi diferente do observado na biomassa em suspensão. Verificou-se, também, que a biomassa responsável pela nitrificação e desnitrificação ocorreu predominantemente no meio suporte, enquanto que a biomassa heterotrófica predominou no lodo em suspensão. / The operating conditions for the combined removal of nitrogen and organic matter in moving- bed biological reactor were investigated. Two bench-scale reactors, two liters each, were operated under intermittent aeration and continuously fed with synthetic wastewater containing ammonia nitrogen (90 to 110 mg/L) and molasses as organic carbon source (COD of 450 to 550 mg/L). Each reactor received different moving-bed materials: polyurethane foam matrices and plastic rings, respectively. During the first experimental period, the reactor containing plastic rings maintained very low nitrogen removal efficiencies during large period. For this reason, the moving-bed was replaced by polyurethane foam matrices and the reactor was re-inoculated with aerobic wastewater plant sludge. Thereafter, the two reactors were similar except for the origin, age and characteristics of the inoculum sludge. First, the wastewater micronutrients were just those contained in the carbon source (molasses). After, the synthetic wastewater composition was changed by adding a solution of micronutrients. This procedure was adopted to achieve a stable nitrification process, because commercial molasses is a very poor regarding its micronutrient composition. As a result of the stable conditions prevalence just after adding micronutrients, organic matter (as COD) removal efficiencies were higher than 85% and complete nitrogen ammonia oxidation was achieved. In nitrogen removal efficiencies were approximately 55%. The performance of the reactors improved after the increase of the anoxic period from1h to 1h15min, and reduction of the hydraulic detention time to less than 12 h. The results obtained in the last operating period indicated the optimum operating conditions was not achieved in this experiment, thus opening the possibility of process improvement in further researches. Microbial populations with different characteristics were developed in suspended growth and attached biomass. Nitrification and denitrification bacteria predominated as attached biomass whereas heterotrophic bacteria predominated as suspended growth biomass.
|
12 |
REATOR DE LEITO ESTRUTURADO COM AERAÇÃO INTERMITENTE PARA TRATAMENTO COMBINADO DE ESGOTO SANITÁRIO E PÓS TRATAMENTO DE EFLUENTE DE RALFOliveira, João Guilherme Baggio de 21 June 2016 (has links)
Made available in DSpace on 2017-07-21T18:53:07Z (GMT). No. of bitstreams: 1
Joao Guilherme Baggio de Oliveira.pdf: 2058376 bytes, checksum: 82bb5fa9502e9c114bd0570d5ed85d62 (MD5)
Previous issue date: 2016-06-21 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Paraná / The dumping of untreated effluents into water bodies can cause serious damage to the environment. Eutrophication, a phenomenon caused by the release of nutrients such as nitrogen and phosphorus, is one of those damages. Their occurrence promotes excessive growth of algae, decreased dissolved oxygen concentration. The conventional nitrogen removal processes employ two stages physically separated to nitrification and denitrification, which increases construction costs and operation of the process. Research has shown that some reactors models are efficient for simultaneous removal of chemical oxygen demand (COD) and total nitrogen (NT). In this sense, the objective of this study was to evaluate a bed reactor structured with intermittent aeration in the removal of COD and NT sewage untreated combined with effluent RALF. Worked with hydraulic retention time (HRT) fixed in 12 hours and recirculation flow (Qr) of the effluent 3, 2 and 1 to the input flow. Worked up with three times aeration: 33%, 50% and 100% of the time. The affluent used was composed of a fraction of 50% of sewage untreated and 50% of effluent from a reactor Anaerobic Fluidized Bed (RALF). The results indicated that there was no statistical difference between the COD removal rates, regardless of the value of Qr and the reactor aeration time. The COD value obtained for the reactor effluent ranged between 27 and 68 mg.L-1. Values of Total Kjeldahl Nitrogen (TKN) affluent ranged between 40 and 52 mg L-1. Obtained removal rate NT of 50 to 78%, effluent generated treated with N-NH4+ content between 0.7 and 7.1 mg.L-1. We observed the occurrence of nitrification and denitrification Simultaneous (NDS) as oxidized forms were detected (nitrite and nitrate) and reduced (N -NH4) nitrogen at all stages studied. It was concluded that the bed reactor structured with intermittent aeration is effective in joint COD removal and sewage nitrogen / O despejo de efluentes não tratados em corpos d’água pode causar sérios danos ao meio ambiente. A eutrofização, fenômeno causado pelo lançamento de nutrientes como o nitrogênio e fósforo, é um desses danos. A sua ocorrência promove o crescimento exagerado de algas, diminuição da concentração de oxigênio dissolvido. Os processos convencionais de remoção de nitrogênio utilizam duas etapas fisicamente separadas para a nitrificação e desnitrificação, o que aumenta custos com construção e operação do processo. Pesquisas têm mostrado que alguns modelos de reatores são eficientes para remoção concomitante de Demanda Química de Oxigênio (DQO) e nitrogênio total (NT). Neste sentido, o objetivo deste trabalho foi avaliar um reator de leito estruturado com aeração intermitente na remoção de DQO e NT de esgoto sanitário não tratado combinado com efluente de RALF. Trabalhou-se com Tempo de Detenção Hidráulica (TDH) fixo em 12 horas evazão de recirculação (Qr) do efluente de 3, 2 e 1 vez a vazão de entrada. Trabalhou-se com três tempos de aeração: 33%, 50% e 100% do tempo.O afluente utilizado foi composto por uma fração de 50% de esgoto sanitário não tratado e 50% de efluente de um Reator Anaeróbio de Leito Fluidizado (RALF). Os resultados indicaram que não houve diferença estatística entre as taxas de remoção de DQO, independentemente de Qr e tempo de aeração do reator. Os valores de DQO obtidos para o efluente do reator variaram entre 27 e 68 mg.L-1. Os valores de Nitrogênio Total Kjeldahl (NTK) afluente variaram entre 40 e 52 mg.L-1. Obteve-se taxas de remoção de NT de 50 a 78%, geraram efluente tratado com teor de N-NH4+ entre 0,7 e 7,1 mg.L-1. Observou-se a ocorrência de Nitrificação e Desnitrificação Simultâneas (NDS), pois foram detectadas formas oxidadas (nitrito e nitrato) e reduzidas (N-NH4+) de nitrogênio em todas as fases estudadas. Foi possível concluir que o reator de leito estruturado com aeração intermitente é eficiente na remoção conjunta de DQO e nitrogênio de esgoto doméstico.
|
13 |
REATOR DE LEITO EMPACOTADO EM ESCALA PILOTO PARA REMOÇÃO DE MATÉRIA ORGÂNICA E NITROGENADA DE ESGOTO SANITÁRIOPolak, Rafael 23 July 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-12-11T11:55:47Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Rafael Polak.pdf: 5152873 bytes, checksum: 5f30b3bcb29a2f08c434a1b4def58c5a (MD5) / Made available in DSpace on 2018-12-11T11:55:47Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Rafael Polak.pdf: 5152873 bytes, checksum: 5f30b3bcb29a2f08c434a1b4def58c5a (MD5)
Previous issue date: 2018-07-23 / Essa pesquisa teve por objetivo principal avaliar o desempenho de um
reator em escala piloto de leito empacotado e fluxo contínuo sob diferentes
condições operacionais de aeração, na remoção biológica de matéria
carbonácea e nitrogenada, de efluente sanitário. O reator possuía um volume
total de 5,65 m³ e volume útil de 4,75 m³, devido ao volume ocupado pelo
material suporte. O meio suporte utilizado para fixação de microrganismos foi o
dispositivo denominado Biobob®, que consiste em uma matriz de espuma de
poliuretano envolta por uma estrutura de polipropileno, com geometria cilíndrica
de 45 mm de diâmetro e 60 mm de altura. O reator foi operado com um Tempo
de Detenção Hidráulica (TDH) de 12 horas, razão de recirculação de 2 vezes
vazão de alimentação e foi alimentado continuamente por afluente composto
por mistura de esgoto sanitário não tratado e efluente de Reator Anaeróbio de
Leito Fluidizado (RALF) na proporção de 1:1 (v:v). Foram explorados três ciclos
de operação de 180 minutos: (10) aerando continuamente por 180 minutos, (2)
aerando 60 minutos e não aerando 120 minutos, e (3) aerando 120 minutos e
não aerando 60 minutos. Os resultados mostraram não haver diferença
estatística nas eficiências de reduções de Demanda Química Oxigênio (DQO)
entre as três condições estudadas, com eficiências médias de 76,34%, 75,32%
e 79,80%, respectivamente, indicando que o tempo de aeração não influenciou
na eficiência de redução. A DQO efluente do reator variou entre 31 mg.L-1 e
206 mg.L-1. A eficiência de nitrificação se mostrou fator limitante na remoção de
NT. As condições (1) e (3) com maiores taxas de nitrificação, 75% e 70%
respectivamente, obtiveram as melhores eficiências de remoção de NT, com
taxas de 65% em ambas. A relação DQO/NTK durante as 3 etapas da pesquisa
foi próxima a 9,59. A condição (3) apresentou diferença estatística significativa
na remoção de NT devido a maior disponibilidade de doadores de elétrons,
com relação DQO/NTK de 11,2. A desnitrificação apresentou médias de
remoções de 87%, 89% e 94%, nas condições 1, 2 e 3, respectivamente. Pelos
resultados obtidos, pode-se concluir que o reator piloto de leito empacotado e
aeração intermitente foi eficiente na remoção simultânea de matéria orgânica e
nitrogenada, podendo ser considerado uma alternativa interessante a ser
utilizada no tratamento combinado de efluente de UASB e esgoto bruto. / The main objective of this research was to evaluate the performance of a pilot
scale reactor of packed bed and continuous flow, on different aeration operating
conditions, in the biological removal of carbonaceous and nitrogenous matter
from sanitary effluent. The reactor has a total volume of 5.65 m³, and a useful
volume of 4.75 m³ due to the volume occupied by the structured bed. The
medium used to fix microorganisms was the device called Biobob®, which
consists of a polyurethane foam matrix enveloped by a polypropylene structure,
with a cylindrical geometry of 45 mm in diameter and 60 mm in height. The
reactor was operated with a 12 hour Hydraulic Retention Time (HRT),
recirculation rate of 2 times feed rate and was continuously fed by a mixture of
untreated sewage and effluent from an Upflow Anaerobic Sludge Blanket
(UASB) in the proportion of 1:1 (v:v). Three 180-minute cycles of operation were
performed: (1) continuous aeration for 180 minutes, (2) aeration 60 minutes and
no aeration for 120 minutes and (3) aeration for 120 minutes and no aeration for
60 minutes. The results showed that there was no statistical difference in the
efficiency of Chemical Oxygen Demand (COD) reductions between the three
conditions studied, with mean efficiencies of 76.34%, 75.32% and 79.80%,
respectively, indicating that the aeration did not influence the reduction
efficiency. The COD concentrations effluent from the reactor varied between 31
mg.L-1 and 206 mg.L-1. The efficiency of nitrification was shown to be a limiting
factor in NT removal. The conditions (1) and (3) with higher nitrification rates,
75% and 70%, respectively, obtained the best NT removal efficiencies, with
rates of 65% in both. The COD / NTK ratio presented a high average during the
3 stages of the research, with an observed value of 9.59. Denitrification showed
mean removals of 87% (1), 89% (2) and 94% (3). Condition (3) presented a
statistically significant difference with the others due to the greater availability of
electron donors, with a COD/NTK ratio of 11.2. From the results, we can
conclude that the packed bed reactor and intermittent aeration is efficient in the
simultaneous removal of organic matter and nitrogen and is an interesting
alternative to be used in the treatment and post treatment of anaerobic reactors.
|
14 |
Remoção de matéria orgânica e nitrogênio de esgoto sanitário em reator de leito estruturado submetido à aeração intermitente e recirculação do efluente / Simultaneous carbon and nitrogen removal from sewage in a structured bed biofilm reactor subjected to intermittent aeration and effluent recirculationRafael Brito de Moura 10 October 2014 (has links)
O objetivo deste trabalho foi o de avaliar o desempenho de um reator de leito estruturado submetido à aeração intermitente (LEAI) na remoção de matéria orgânica e nitrogênio de esgoto sanitário. O reator apresentava um volume total de 11,6 L, com uma porosidade do leito de 52%. O leito estruturado era composto de 13 estruturas cilíndricas (diâmetro igual a 3 cm) de espuma de poliuretano, dispostas verticalmente no interior do reator. A alimentação do reator era feita continuamente com esgoto sanitário, sendo este proveniente de um interceptor de esgoto que passava próximo ao laboratório onde o sistema foi montado. O reator era provido de sistema de recirculação interna, com razão de recirculação igual a 3, valor este adotado após a realização de ensaios hidrodinâmicos. Foram testadas 4 condições operacionais diferentes, variando-se o tempo de detenção hidráulica (TDH) e os períodos de aeração e não aeração. Para cada condição operacional, foram feitos os seguintes estudos: avaliação da eficiência de remoção de matéria orgânica e nitrogênio, determinação da atividade nitrificante e desnitrificante, determinação do número mais provável (NMP) da comunidade nitrificante e desnitrificante, perfis temporais e análise da comunidade microbiana. O sistema apresentou elevada remoção de N-total, com valores médios de 80% para valores de TDH de 12 e 10 horas, sob 2 horas de aeração e 1 hora sem aeração. Com a diminuição do TDH para 8 horas, houve queda na eficiência do sistema para 70% (mantendo-se os períodos de aeração de 2 horas e não aeração de 1 hora). Alterando-se o período de aeração para 3 horas, mantendo-se em 1 hora o período sem aeração, o reator apresentou eficiência média de remoção de N-total de 79% com o TDH de 8 horas. A remoção de DQO foi elevada em todas as fases, com valores médios em torno de 90%. Os resultados da atividade nitrificante e desnitrificante foram condizentes com valores encontrados na literatura para sistemas que operam com remoção simultânea de matéria orgânica e nitrogênio. Os perfis temporais mostraram que não houve variação nas formas de nitrogênio (N-NH4+, N-NO2- e N-NO3-) no efluente, apesar da operação sob a aeração intermitente devido ao grau de mistura imposto pela recirculação interna. A concentração de sólidos no efluente foi relativamente baixa quando comparada à concentração de efluentes de reatores de biomassa suspensa, com valor máximo de SSV igual a 108mgSSV.L-1. A presença do Metazoário Aelosomas sp no efluente do reator indica um possível consumo do lodo excedente no reator por esses microrganismos. As análises microbiológicas mostraram uma elevada abundância relativa de gêneros aeróbios facultativos, capazes de utilizar N-NO3- e N-NO2- como receptor de elétrons na ausência de oxigênio. Também se verificou a presença do gênero Comamonas sp em elevada abundância relativa. Esse gênero apresenta microrganismos capazes de realizar a nitrificação heterotrófica e a desnitrificação aeróbia. No entanto, os ensaios realizados não permitem inferir sobre a ocorrência desses processos. Desse modo, os processos convencionais de nitrificação e desnitrificação, tanto pela estratificação do biofilme devido à formação de gradiente de concentração de oxigênio dissolvido, quanto devido à aeração intermitente, certamente tiveram papel preponderante na remoção de nitrogênio. Os resultados obtidos permitem considerar o reator LEAI como uma alternativa tecnicamente viável para a remoção simultânea de matéria orgânica e nitrogênio de esgotos sanitários. / This study aimed at evaluating the organic matter and nitrogen removal from sewage in a structured bed reactor subjected to intermittent aeration. The reactor had a total volume of 11.6 L and bed porosity of 52%. Thirteen polyurethane foam cylinders of 3 cm diameter and 60 cm height were fixed vertically inside the reactor using PVC rods. The reactor was continuously fed with sewage collected from a sanitary sewer passing near the laboratory where the system was assembled. The reactor was provided with internal recirculation system with a recirculation ratio at 3, a value adopted after conducting hydrodynamic tests. Four different operating conditions were tested, varying the hydraulic retention time (HRT) and aeration and non-aeration periods. Nitrogen and organic matter removal efficiencies, nitrifying and denitrifying activities, and the most probable number (MPN) of nitrifying and denitrifying communities were evaluated for each operational condition. The reactor presented a Total-N removal efficiency of 80%, at HRT of 12 hours and 10 hours and aerated and non-aerated periods of 2 hours and 1 hour, respectively. With decreasing the HRT to 8 hours, the Total-N removal efficiency decreased to 70% for the same aeration and non-aeration periods. After increasing the aerated period to 3 hours and keeping the non-aerated periods of 1 hour and HRT of 8 hours, the system attained the Total-N removal efficiency of 79%. COD removal efficiencies were about 90% in all operational condition. Nitrifying and denitrifying activities were similar to those found in the literature for systems presenting simultaneous nitrification and denitrification, and carbon removal. No variation in nitrogen forms (NO3--N, NO2--N and NH4+-N) was observed during a cycle of intermittent aeration. The solids concentration in effluent was relatively low compared to the concentration of suspended-growth biomass reactors, with a maximum value of VSS of 108 mgVSS.L-1. The presence of the metazoan Aelosomas sp in the effluent in all operational conditions indicated a possible use of the excess sludge in the reactor by these microorganisms. Microbiological analysis showed a high relative abundance of aerobic/facultative microorganisms, capable to use NO3--N and NO2--N as electron acceptor in the absence of oxygen. It was also verified the presence of the genus Comamonas sp with high relative abundance. This genus presents microorganisms able to perform heterotrophic nitrification and aerobic denitrification. However, the assays do not allow us to infer the occurrence of these processes. Thus, the conventional processes of nitrification and denitrification certainly played a preponderant role in nitrogen removal both by the stratification of the biofilm due to the formation of a concentration gradient of dissolved oxygen, as due to the intermittent aeration. The results allow considering the reactor as a viable technological alternative for the simultaneous removal of organic matter and nitrogen of sewage.
|
15 |
Remoção de nitrogênio via nitrito em reator operado em bateladas seqüenciais contendo biomassa imobilizada e aeração intermitente / Nitrogen removal through nitrite in sequential batch reactor with immobilized biomass and intermittent aerationLeonidia Maria de Castro Daniel 14 October 2005 (has links)
Um reator de leito fixo, preenchido com biomassa imobilizada em espuma de poliuretano, foi operado em bateladas seqüenciais, alimentado com substrato sintético com concentração de nitrogênio amoniacal de 125, 250, 500 e 40 mg/L. O principal objetivo da pesquisa foi verificar a possibilidade de se promover a nitrificação curta no reator submetido à aeração intermitente, com a formação de nitrito como principal composto intermediário, seguida da desnitrificação. Para concentração de nitrogênio amoniacal de 125 e 250 mg/L o perfil temporal das concentrações de nitrogênio monitoradas evidenciou que tempo de ciclo de 24 horas foi excessivo. Durante a operação do reator submetido à concentração de nitrogênio amoniacal de 500 mg/L e de 40 mg/L, ficou evidente a influência do modo de operação, quanto à concentração de oxigênio e extensão dos períodos aeróbios e anóxicos, no tempo de ciclo necessário. Para todas as concentrações de nitrogênio amoniacal estudadas a duração do período de aeração foi suficiente para nitrificar uma fração do N-amoniacal afluente, de modo que as concentrações de nitrito e ácido nitroso não atingissem níveis tóxicos ao processo de oxidação de N-amoniacal. Ao longo do período de operação, o nitrogênio na forma de nitrito tornou-se a forma oxidada predominante e foi possível manter este acúmulo de nitrito em todas as etapas de operação do reator, mesmo alterando a concentração de oxigênio dissolvido, prolongando o período de aeração e, reduzindo a concentração de amônia livre. Constatou-se, portanto, ser possível obter-se processo estável de remoção de nitrogênio em reator operado em bateladas seqüenciais, submetido a etapas de aeração e não aeração em um mesmo ciclo. Esse modo de operação permitiu o estabelecimento do processo de nitrificação parcial a nitrito nas etapas aeradas e desnitrificação nas etapas anóxicas / A bench-scale sequencing batch reactor filled with polyurethane foam matrices was fed with synthetic substrate containing different influent ammonium nitrogen concentrations (120, 250, 500 and 40 mg/L) and subjected to different operating conditions. The main objective was to verify the possibility off promoting short nitrification in the reactor operated under intermittent aeration to obtain nitrite as the main intermediate compound to be denitrified during the anoxic periods. The profiles of the monitored nitrogen species along the cycles allowed verifying that the time cycle of 24 hours was excessive for ammonium nitrogen concentrations of 125 and 250 mg/L. The influence of the operating parameters relative to the dissolved oxygen concentration and extension of aerobic and anoxic periods on the cycle time was evident during the operation at ammonium nitrogen concentrations of 500 and 40 mg/L. The duration of the aeration periods was long enough to allow a fraction of the influent ammonium to be nitrified for all the ammonium nitrogen concentrations studied. The concentrations of nitrite and nitrous acid have never reached the toxic levels to affect ammonia oxidation. Nitrite was the predominant form of oxidized nitrogen along all the operating periods. Nitrite accumulation occurred during all the stages of reactor operation, even when the reactor was subjected to different dissolved oxygen concentrations, length of aeration period and free ammonia concentration. Therefore, stable process of nitrogen removal was achieved in the sequencing batch reactor containing immobilized biomass subjected to a wide range of ammonium nitrogen concentrations. The operation way consisting of intermittent aeration followed by non aeration periods in the same cycle allowed the establishment of the process of partial nitrification to nitrite in the aerated steps followed by denitrification in the anoxic steps
|
16 |
Utilização de glicerol como fonte de carbono para desnitrificação e remoção biológica de fósforo em reator submetido à aeração intermitente / Glycerol as carbon source for denitrification and biological phosphorus removal in a reactor subjected to intermittent aerationRodrigo Braz Carneiro 07 April 2015 (has links)
Esse trabalho buscou avaliar a possibilidade de utilização do glicerol como fonte de carbono para a desnitrificação conjunta à remoção biológica de fósforo de um efluente sintético em um reator de fluxo contínuo submetido à aeração intermitente e com biomassa suspensa. O regime operacional do reator foi dividido em duas fases: a primeira visando somente a remoção de nitrato, testando diferentes relações Carbono/Nitrogênio (C/N) em Tempo de Detenção Hidráulica (TDH) de 4 horas; e a segunda visando a remoção de nitrato e fosfato com períodos de aeração e não aeração de 2 e 4 horas respectivamente, para uma relação Carbono/Fósforo de 10 ± 1. Na primeira fase operacional foram testadas 3 relações C/N, a saber: 1,2 ± 0,1; 1,5 ± 0,1 e 1,8 ± 0,2. Para a relação C/N de 1,8 ± 0,2 foi possível atingir uma maior eficiência de desnitrificação com uma maior estabilidade operacional - 91 ± 8%. Para a segunda fase de operação que apresentou relação C/N de 3,5 ± 0,2, a desnitrificação foi completa na maior parte do tempo com 99 ± 2% de eficiência de remoção de NOx (nitrato mais nitrito), indicando que a desnitrificação com glicerol é favorecida para relações C/N mais altas. Não foi evidenciado uma remoção biológica de fósforo expressiva (9 ± 12%), indicando que não houve desenvolvimento dos organismos acumuladores de fósforo (OAPs), uma vez que a liberação de fosfato durante a fase não aerada não ocorreu. Isso pode ser explicado pela falta de ácidos graxos voláteis (AGV), que seriam provenientes da degradação anaeróbia do glicerol, sendo a maior parte desse consumida na desnitrificação. Portanto, o teor de nitrato pode ter sido um fator de impedimento ao desenvolvimento dos OAPs. Pelos ensaios de microscopia óptica foi observado a presença de bactérias filamentosas semelhantes às do gênero Beggiatoa, que também podem ter consumido parte dos substratos da fermentação do glicerol. Por essas razões, sugere-se avaliar outras configurações de reatores de modo a promover uma efetiva fermentação do glicerol previamente ao sistema de remoção de fósforo. / This study aimed to evaluate the feasibility of glycerol as a carbon source for denitrification and biological phosphorus removal of a synthetic wastewater in a continuous flow reactor with suspended biomass and subjected to intermittent aeration. The reactor operation was divided in two phases: the first one aimed only at removing nitrate, testing different C/N (Carbon/Nitrogen) ratios at an HRT (Hydraulic Retention Time) of 4 hours; and the second one aimed at the removal of nitrate and phosphate. During the second phase, the reactor was subjected to periods of aeration and non-aeration of 2 and 4 hours, respectively, for a C/P (Carbon/Phosphorus) ratio of 10 ± 1. In the first operational phase, three C/N ratios were tested, as follows: 1.2 ± 0.1; 1.5 ± 0.1 and 1.8 ± 0.2. For the C/N ratio of 1.8 ± 0.2, it was possible to achieve higher denitrification efficiency with greater operational stability - 91 ± 8%. For the second operational phase, with the C/N ratio of 3.5 ± 0.2, the denitrification was complete most of the time presenting 99 ± 2% of NOx (nitrate and nitrite) removal efficiency, indicating that the denitrification with glycerol is enhanced at higher C/N ratios. The biological phosphorus removal in this phase was not significant (12 ± 9%), indicating that there was no development of Phosphorus Accumulating Organisms (PAO), since the phosphate release during the anaerobic phase did not occur. This can be explained by the lack of Volatile Fatty Acids (VFA), which would come from the anaerobic degradation of glycerol that was consumed in denitrification. Therefore, the nitrate content may have been an interfering factor to the development of PAO. The optical microscopy analysis indicated the presence of filamentous bacteria similar to the genus Beggiatoa, which can also have consumed part of the substrates from the glycerol fermentation. For these reasons, it is suggested to evaluate other reactor configurations in order to promote the effective fermentation of glycerol previously to the phosphorus removal system.
|
17 |
Remoção de carbono e nitrogênio em reator de leito móvel submetido à aeração intermitente / Nitrogen and carbon removal in moving bed reactor operated under intermittent aerationLissa Maria Nocko 30 May 2008 (has links)
O lançamento de águas residuárias contendo compostos nitrogenados tem um importante impacto sobre a saúde e o meio ambiente, tornando necessária a incorporação de processos de remoção desses compostos nos sistemas de tratamento de águas residuárias. Neste trabalho, foram estudadas as condições de operação para promover a remoção conjunta de nitrogênio e matéria orgânica em reator biológico de leito móvel, contínuo, operado sob aeração intermitente, alimentado com água residuária sintética contendo nitrogênio amoniacal (90 a 110 mg/L) e melaço como matéria orgânica (DQO de 450 a 550 mg/L). Foram utilizados dois reatores em escala de bancada, cada um com dois litros de volume útil, contendo diferentes meios suportes para a imobilização da biomassa: matrizes de espuma de poliuretano e anéis plásticos. Na primeira etapa experimental, o reator contendo anéis plásticos apresentou eficiências de remoção de nitrogênio muito baixas. Na segunda etapa, trocou-se o material suporte por matrizes de espuma de poliuretano inoculadas com lodo aeróbio de estação de tratamento de águas residuárias. A partir de então, trabalhou-se com dois reatores de mesma configuração, exceto pelas origens, idades e características dos lodos de inóculo. Inicialmente, a alimentação foi realizada utilizando-se apenas os micronutrientes contidos no melaço. Posteriormente, a composição da água residuária foi alterada, introduzindo-se solução de micronutrientes, pois se concluiu que a instabilidade no processo de nitrificação devia-se ao fato de o melaço comercial apresentar deficiências nutricionais. Como resultado, em condições de estabilidade operacional, foram obtidas eficiências de remoção de DQO superiores a 85%, oxidação total do nitrogênio amoniacal e eficiências de remoção de nitrogênio de aproximadamente 55%. Variações posteriores nas condições de operação, como o aumento do período anóxico (de 1h para 1h15min) e redução do tempo de detenção hidráulica (para valores inferiores a 12 horas), resultaram em melhora no desempenho dos reatores. Os resultados obtidos permitem admitir que as melhores condições de operação não foram atingidas durante o experimento, abrindo a possibilidade para a otimização do processo em pesquisas futuras. Constatou-se que o desenvolvimento das populações microbianas imobilizadas no meio suporte foi diferente do observado na biomassa em suspensão. Verificou-se, também, que a biomassa responsável pela nitrificação e desnitrificação ocorreu predominantemente no meio suporte, enquanto que a biomassa heterotrófica predominou no lodo em suspensão. / The operating conditions for the combined removal of nitrogen and organic matter in moving- bed biological reactor were investigated. Two bench-scale reactors, two liters each, were operated under intermittent aeration and continuously fed with synthetic wastewater containing ammonia nitrogen (90 to 110 mg/L) and molasses as organic carbon source (COD of 450 to 550 mg/L). Each reactor received different moving-bed materials: polyurethane foam matrices and plastic rings, respectively. During the first experimental period, the reactor containing plastic rings maintained very low nitrogen removal efficiencies during large period. For this reason, the moving-bed was replaced by polyurethane foam matrices and the reactor was re-inoculated with aerobic wastewater plant sludge. Thereafter, the two reactors were similar except for the origin, age and characteristics of the inoculum sludge. First, the wastewater micronutrients were just those contained in the carbon source (molasses). After, the synthetic wastewater composition was changed by adding a solution of micronutrients. This procedure was adopted to achieve a stable nitrification process, because commercial molasses is a very poor regarding its micronutrient composition. As a result of the stable conditions prevalence just after adding micronutrients, organic matter (as COD) removal efficiencies were higher than 85% and complete nitrogen ammonia oxidation was achieved. In nitrogen removal efficiencies were approximately 55%. The performance of the reactors improved after the increase of the anoxic period from1h to 1h15min, and reduction of the hydraulic detention time to less than 12 h. The results obtained in the last operating period indicated the optimum operating conditions was not achieved in this experiment, thus opening the possibility of process improvement in further researches. Microbial populations with different characteristics were developed in suspended growth and attached biomass. Nitrification and denitrification bacteria predominated as attached biomass whereas heterotrophic bacteria predominated as suspended growth biomass.
|
18 |
Efeitos do tempo de aeração no desempenho de reator de leito estruturado e aeração intermitente usado para remoção de matéria orgânica e nitrogênio de efluente de reator UASB / Effects of aeration time in structured-bed reactor under intermittent aeration used to remove organic matter and nitrogen of a UASB reactor effluentBruno Garcia Silva 19 May 2016 (has links)
Utilizou-se reator de leito estruturado e aeração intermitente (RLEAI) como pós-tratamento de efluentes de reator UASB tratando esgoto sanitário. O volume total e o tempo de detenção hidráulica (TDH) do reator UASB eram de 11,2 L e 9 horas, respectivamente. O RLEAI possuía volume total de 11,0 L e, devido às hastes cilíndricas verticais de espuma de poliuretano usadas como suporte para a biomassa, o volume útil foi de 9,6 L. Este reator foi operado com um TDH de 12 horas, razão de recirculação igual a 3 e foi alimentado continuamente com efluente do reator UASB. O objetivo deste trabalho foi avaliar a influência do tempo de aeração no desempenho do RLEAI na remoção de matéria orgânica e nitrogênio. O reator foi operado com aeração contínua, e tempos de aeração intermitentes (tempo aerado/não aerado) de 2h/1h, 1h/1h, 0,75h/1,25h, 1h/ h e 1h/3h. Em todas as fases a DQO efluente ao sistema ficou entre 26 e 42 mg.L-1. A fase de aeração contínua foi fundamental para o estabelecimento da comunidade nitrificante no sistema. A oxidação do nitrogênio total (como NTK) para nitrato aumentou de 62% (aeração contínua ) para 82% (aeração intermitente de 1h/2h) devido à alcalinidade gerada pela desnitrificação, estimulada pelo período não aerado. Na fase 1h/3h a oxidação do NTK foi prejudicada pela falta de oxigênio, e a eficiência nesta fase foi de 42%. A maior remoção estável de N-total foi obtida na fase 1h/2h com eficiência de 29%. Foi observado no ensaio em batelada que a velocidade de desnitrificação via nitrato aumentou de 0,90 mg N. g SSV-1.h-1 para 2,55 mg N. g SSV-1.h-1 após aclimatação da biomassa em condições de excesso de matéria orgânica. Concluiu-se que a remoção de N-total foi limitada pela baixa quantidade de matéria orgânica advinda do reator UASB, sendo a relação DQO/N do afluente ao RLEAI de 3,04. A elevada oxidação de NTK e de remoção de matéria orgânica, aliadas à baixa produção sólidos e ao alto tempo de retenção celular (139 dias), mostram que o RLEAI é uma alternativa interessante em comparação às tecnologias praticadas atualmente para pós tratamento de efluentes de reatores anaeróbios. / This study used a structured bed reactor under intermittent aeration for post-treatment of UASB rector treating domestic sewage. The UASB reactor had a total volume of 11.2 L and 9 hours of hydraulic retention time (HRT). The structured bed reactor had a total volume of 11.0 L and working volume of 9.6 L due to the vertical cylindrical rods with polyurethane foam used as a support for the biomass. This reactor was operated whit 12 hours of HRT, recirculation ratio equal to 3 and was continuously fed with effluent from the UASB reactor. The aim of this study was to evaluate the influence of aeration time on RLEAI performance in removal of organic matter and nitrogen. For this the reactor was operated with continuous aeration and intermittent aeration periods (time aerated/ non-aerated) of 2h/1h, 1h/1h, 0.75h/1.25h, 1h/2h e 1h/3h. During all operation time the COD effluent to the system it was between 26 and 42 26 e 42 mg.L-1. The continuous aeration operation was fundamental to the establishment of the nitrifying microorganism community in the system. The TKN oxidation to nitrate increase from 62% (continues aeration) to 82% (intermittent aeration 1h/2h) due to the alkalinity generated by denitrification, that was stimulated by non-aerated period. In the intermittent aeration period of 1h/3h the NTK oxidation was damaged by a lack of oxygen; the efficiency at this stage was 42%. The most stable total nitrogen removal was obtained in 1h/2h aeration period with 29% efficiency. It was observed in the batch test that nitrate denitrification rate increased from 0.90 mg N. g VSS-1.h-1 to 2.55 mg N. g VSS-1.h-1 after acclimation of biomass in conditions of excess organic matter. It was inferred that the removal of total nitrogen was limited by the low amount of organic matter load from the UASB reactor; the COD/N ratio of the influent was 3.04. The high NTK oxidation and high organic matter removal, combined with low solid production and high cell retention time (139 days), leads to the conclusion that the structured bed reactor under intermittent aeration is an interesting alternative compared to the technologies currently applied for post treatment of anaerobic reactors effluent.
|
19 |
Estratégia operacional de sistema formado por reator não compartimentado com setores com aeração/sem aeração precedido por reator anaeróbio / Operational strategies of system consisting of non-compartmentalized aerated reactor with sectors with aeration/without aeration preceded by an anaerobic reactorAlmeida, Aurélia de Oliveira 10 October 2014 (has links)
A opção por sistemas biológicos prevalece para o tratamento do esgoto sanitário. Nas décadas recentes, sistemas que possuem regiões e/ou zonas anaeróbia, anóxica e aeróbia têm-se mostrado como alternativas atraentes para remoção simultânea de matéria orgânica, nitrogênio e fósforo. No entanto, os aspectos operacionais ainda merecem ser objeto de estudo para alcançar desempenho otimizado. Nesse cenário, com intuito de comparar alternativas para a operação das unidades de tratamento de esgoto, o presente trabalho propôs-se a estudar estratégias operacionais associadas ao monitoramento, em tempo real, sem adição de fonte externa de carbono, para um reator aerado não compartimentado com crescimento suspenso e fluxo contínuo precedido de reator anaeróbio. O sistema experimental, em escala de bancada, era constituído de um reator anaeróbio, com volume útil de 43,54 L, e reator aerado, com volume útil de 68,07 L; sendo que este era formado por sete setores, em série, sem separação física. O estudo foi dividido em duas etapas: I - estudo da variação dos volumes da região aerada e da não aerada; II - estudo da aeração intermitente com ciclo de aeração/agitação pré-fixado e controlado em tempo real por sistema informatizado. Em todas as Etapas do estudo ocorreu elevada remoção de DBO e conversão de NTK para nitrato, contudo não se conseguiu obter desnitrificação em nível desejado. O uso de reatores com setores sequenciais sem divisão física (Etapa I) dificultou a obtenção de regiões distintas predominantemente anóxica e aeróbia, comprometendo a remoção de nitrogênio (principalmente a desnitrificação). A maior eficiência média de remoção de nitrogênio alcançada no reator aerado foi de 35,6% (Etapa II), quando o reator era operado com aeração intermitente sendo o ciclo de aeração/agitação controlado em tempo real. A estratégia de operação com aeração intermitente, estudada na Etapa II, favoreceu a remoção de nitrogênio. A aeração intermitente demonstrou ser uma opção promissora comparada à aeração contínua em setores específicos do reator. O controle automatizado e informatizado em tempo real dos ciclos de aeração/agitação pode ser aplicado no aperfeiçoamento da operação dos sistemas de tratamento de esgoto sanitário. / The option of biological systems prevails for the treatment of sewage waste and in recent decades, systems that have anaerobic, anoxic, aerobic regions and / or zones have proven attractive for simultaneous removal of organic matter, nitrogen and phosphorus. However, the operational aspects still deserve to be studied in order to achieve the optimized performance of these systems. In this scenario, in order to compare alternatives for the operation of sewage treatment plants, the present work aimed to study operational strategies associated with monitoring, in real time, without the addition of external carbon source, for a non-compartmentalized aerated reactor with growth suspended and continuous flow preceded by anaerobic reactor. The experimental system in bench scale consisted of an anaerobic reactor, with a volume of 43.54 L and an aerated reactor, with a volume of 68.07 L; consisting of seven sectors, in series, without physical separation. The study was divided into two stages: I - study of the variation of the volume of the aerated and non-aerated regions; II - study of intermittent aeration with cycle of aeration/agitation controlled by a pre-fixed time interval; and controlled in real time by a computerized system. In all Stages of the study high BOD removal and conversion of TKN to nitrate occurred, but were unable to obtain denitrification at desired level. The use of reactors with sequential sectors without physical division (Stage I) made it difficult to obtain predominantly distinct anoxic and aerobic regions, compromising the removal of nitrogen (mainly the denitrification). The highest average removal efficiency of nitrogen attained in aerated reactor was 35.6% when the reactor was operated with intermittent aeration with aeration cycle controlled in real time. The operation strategy with intermittent aeration, studied in Stage II, favored the removal of nitrogen. The intermittent aeration proved to be a promising option compared to continuous aeration in specific sectors of the reactor. The automated and computerized control in real-time of the aeration / agitation cycles can be applied in improving the operation of sewage waste treatment systems.
|
20 |
Remoção de nutrientes do efluente de reator anaeróbio utilizando reatores microaeróbio e com aeração intermitente seguidos de flotação por ar dissolvido / Nutrient removal of anaerobic effluent reactor using microaerobic and intermittent aeration reactors followed by DAFMarchetto, Margarida 07 December 2001 (has links)
O principal objetivo deste trabalho consistiu em avaliar o desempenho de um sistema experimental para pós-tratamento de reatores anaeróbios. Foram testados reator microaerado e reator com aeração intermitente, seguidos de flotação por ar dissolvido. Foram avaliadas condições para se obter nitrificação, desnitrificação e remoção de fósforo, em reator com baixa concentração de OD e em reator em que se alternaram fases aeróbia e anaeróbia. O trabalho foi desenvolvido em duas etapas distintas: a Etapa I constituiu de ensaios preliminares, utilizando instalação em escala de laboratório, alimentados com efluente de reator anaeróbio compartimentado, composta de sistema de aeração com quatro reatores em paralelo, com capacidade de 11,5 L cada, operando em regime hidráulico contínuo, com concentrações de OD na faixa de 0,2 a 0,9 mg/L, em temperatura controlada de 30±2°C. Na Etapa I também foram operados reatores com aeração intermitente. Na Etapa II, empregou-se instalação para tratamento aeróbio, com capacidade de 100 L, seguida de flotador, em temperatura ambiente de 25±6°C, sendo operado um reator microaerado e outro com aeração intermitente; ambos foram alimentados com efluente de um reator anaeróbio de leito expandido. O sistema com aeração intermitente (θh: 6 h) mostrou-se estável, apresentando elevada remoção média de DQO (92%), de P-PO4-3 (90%) e de nitrogênio (sem utilização de fonte externa de carbono; apenas com recirculação adequada do lodo). Para θh médio de 8 h, nos ensaios com ciclos alternados de 2 h, com aeração e 4 h, sem aeração, foi obtida remoção máxima de P-PO4-3, de 95% para as amostras brutas e 97% para as amostras filtradas, com remoção média de 84%, e 88%, respectivamente. Considerando apenas os valores médios, registrou-se ligeira queda de remoção de P-PO4-3, e de DQO em relação ao período com θh médio de 6 h. Os resultados com aeração intermitente foram sensivelmente melhores em relação aos obtidos com microaeração. / The aim of this research the performance evaluation of a pilot system for post treatment of anaerobic reactors. Microaeration and intermittent aeration reactors, followed by dissolved air flotation (DAF) were examined. It was assessed the conditions to obtain nitrification, denitrification and phosphorus removal, in reactor operated with low concentration of OD and in a reactor operated were alternated aerobic and anaerobic phases were used. The research was developed in two different stages. The first one, constituted of preliminary test, using installation in laboratory scale, fed with effiuent of compartment anaerobic reactor. This system was composed of aeration system with four reactors in parallel, with 11,5 L each, operating in continuous flow, with concentrations of DO between 0.2 to 0.9 mg/L, in controlled temperature of 30±2 ºC. The reactors were also operated with intermittent aeration. In the second stage, an installation with 100L was used for aerobic treatment, followed by DAF, in room temperature of 25±6°C. One reactor was operated under microaeration and another with intermittent aeration. Both were fed with effiuent of an expanded bed anaerobic reactor. The system with intermittent aeration (θh: 6 h) shown stable, presenting high COD removal of (92%) and phosphorus removal (90%), without use of external carbon source; just with adapted recirculation of the sludge. For an average hydraulic retention time of 8 h, in the test with alternate cycles of 2 h with aeration and 4 h without aeration, it was obtained a maximum removal of P-PO4-3 equal 95% for the raw samples and 97% for the filtered samples, with average removal of 84%, and 88%, respectively. The results with intermittent aeration were significantely better in relation to the obtained with microaeration.
|
Page generated in 0.1286 seconds