Tratamento de esgoto sanitário em um reator de leito expandido em escala plena, operado com regiões anaeróbia e aeróbia sobrepostas / Treatment of sanitary wastewater in a full scale expanded bed reactor, operated with overlap anaerobic and aerobic regions

Rafael Ceribelli da Silva 26 June 2009 (has links)
A presente pesquisa teve como objetivo principal a avaliação do desempenho de um reator de leito expandido (159,0 \'M POT.3\'), em escala plena, operado sob condições anaeróbia e anaeróbia-aeróbia sobrepostas, tratando esgoto sanitário. Como objetivos específicos, foi avaliado o uso de areias comerciais para complementação do leito de partículas, bem como a distribuição do material suporte ao longo da altura do reator. Além disso, houve a simulação da flotação do efluente do sistema a fim de otimizar a eficiência na remoção de sólidos, visto pela ineficiência do sistema na separação dos sólidos biológicos. Dentre os materiais selecionados para compor o leito de partículas, foi escolhida a areia com tamanho médio dos grãos igual a 0,69 mm e massa específica de 2690 kg.\'M POT.-3\'. Esta pesquisa foi dividida em duas etapas experimentais, sendo que a primeira o sistema foi operado somente sob a condição anaeróbia, enquanto na segunda, o sistema foi submetido à condição anaeróbia e aeróbia sobrepostas. Para a primeira etapa, o sistema obteve maior eficiência na remoção de matéria orgânica, com TDH de 14 horas, quando foi removido 0,84 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 1,26 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQObruta, DQOfilt, DBObruta, DBOfilt, SST e SSV foram de 65%; 64%; 80%; 70%; 58% e 69%. O efluente apresentou, em média, 245 mgDQObruta/L, 117 mgDQOfilt/L, 104 mgDBObruta/L, 76 mgDBOfilt/L; 88 mgSST/L e 69 mgSSV/L. O grau de amonificação obtido foi de 90%, evidenciando a potenciabilidade do sistema na conversão de matéria nitrogenado orgânico em amoniacal. Para a segunda etapa, a maior eficiência na remoção de matéria orgânica foi obtida com TDH de 16 horas, quando foi removido 0,29 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 0,84 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQOfilt e DBOfiltr foram de 80% e 95%, respectivamente. O efluente apresentou, em média, 72 mgDQOfiltr/L, e 13 mgDBOfiltr/L. O grau de amonificação obtido foi de 85%, no entanto houve baixa eficiência na oxidação do \'N\'-amoniacal, no máximo 25%, sendo que as concentrações máximas no efluente foram de 4 mg\'N\'-\'NO IND.2\'POT.-\'/L e 2 mg\'NO IND.3\'POT.-\'/L, respectivamente. Em relação à distribuição do material suporte, foi verificada que a proporção de carvão ativado granular e carvão antracitoso foi superior em relação à areia, nos diferentes pontos de coleta, sendo que essa proporção tendeu a se reduzir ao longo das amostragens, além disso, foram verificadas que as características do fluxo não estão adequadas para proporcionar a fluidificação/expansão do leito de partículas. Os melhores resultados obtidos na simulação da flotação do efluente, quando foi aplicada recirculação com concentração de ar de 17,5 mgar/Lam, e velocidade ascensional de 10 cm/min. As eficiências de remoção de SST; SSF; SSV; DQO, cor e turbidez obtidas foram de 64; 82; 62; 62; 53 e 73%, respectivamente. O efluente flotado apresentou 63 mgSST/L; 5 mgSSF/L; 59 mgSSV/L; 127 mgDQObruta/L, 431 uC e 29 uT. / This present research had as main objective the evaluation of the performance of a full scale expanded bed reactor (159.0 \'M POT.3\'), operated under anaerobic and overlapping anaerobic-aerobic, treating sanitary wastewater. As specific objectives, it was evaluated using commercial sand to complement the bed of particles and distribution of material support along the height of reactor. Besides, it was simulated the flotation of the effluent system in order to optimize the efficient removal of solids, due to inefficiency of the system in the separation of biological solids. Among the materials selected to compose the bed of particles was chosen with the average size of sand grains equal to 0.69 mm and density of 2690 kg.\'M POT.-3\'. This research was divided into two experimental stages, the first being that the system was operated only under the anaerobic condition, while the second, the system was submited to anaerobic and aerobic conditions overlaped. For the first step, the system achieved greater efficiency in removing organic matter, with hydraulic detention time of 14 hours, when it was removed from 0.84 kgCODraw/\'M POT.3\'.day, which was applied 1.26 kgCOD/\'M POT.3\'.day. The mean removal efficiencies of DQOraw, DQOfiltered, BODraw, BODfiltered, TSS and VSS were 65%; 64%; 80%; 70%; 58% and 69%. The effluent had an average of 245 mgCODraw/L; 117 mgCODfiltered/L; 104 mgBODraw/L; 76 mgBODfiltered/L; 88 mgTSS/L and 69 mgVSS/L. The ammonification obtained was 90%, demonstrating the potencial of the system in the conversion of organic matter into ammonia nitrogen. For the second stage, the most efficient in the removal of organic matter was obtained with hydraulic detention time of 16 hours when it was removed from 0.29 kgCODraw/\'M POT.\'3.day, which was applied 0.84 kgCODraw/\'M POT.3\'.day. The mean removal efficiencies of CODfiltered and BODfiltered were 80% and 95%, respectively. The effluent had an average of 72 mgCODfiltered/L, and 13 mgBODfiltered/L. The ammonification obtained was 85%, however there was low efficiency in oxidation of ammonia-\'N\', at most 25%, and the maximum concentrations in the effluent were 4 mg\'N\'-\'NO IND.2\'POT.-\'/L and 2 mg\'N\'-\'NO IND.3\'POT.-\'/L, respectively. Regarding the distribution of material support, it was found that the proportion of activated granular carbon and anthracite carbon was higher on sand, in different points of collection, whereas this proportion tended to drop over the sample, moreover, was found that the characteristics of the flow are not adequate to provide fluidization/expansion of the bed of particles. The best results obtained in the simulation of the flotation of the effluent when it was applied with recirculation of air concentration of 17.5 mgair/Lsample, and ascension velocity of 10 cm/min. Removal efficiencies of TSS; FSS; VSS; COD, color and turbidity were obtained from 64; 82; 62; 62; 53 and 73%, respectively. The effluent had 63 mgTSS/L; 5 mgFSS/L; 59 mgVSS/L; 127 mgCODraw/L; 431 uC and 29 uT.
22

Reator anaeróbio-aeróbio de leito fixo, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Antonio Pedro de Oliveira Netto 28 March 2007 (has links)
Este trabalho avaliou o desempenho de um sistema que combina os processos anaeróbio e aeróbio, para tratamento de esgoto sanitário, operado de modo contínuo sem e com recirculação da fase líquida. A combinação dos processos anaeróbio e aeróbio tem como objetivo aproveitar as vantagens de cada um, minimizando seus aspectos negativos. Foi utilizado um reator, em escala de bancada, de leito fixo e fluxo contínuo de escoamento ascendente com argila expandida e espuma de poliuretano como suportes de imobilização da biomassa. O desempenho do sistema foi avaliado em três diferentes tempos de detenção hidráulica (TDH), 6, 8 e 10 horas, na fase anaeróbia, nos quais os melhores valores de remoção de matéria orgânica chegaram a 80%, com valores de DQO efluente abaixo de 150 mg/L. Com a inserção da fase aeróbia ao sistema (TDH de aproximadamente 11 horas, sendo 8 horas para a fase anaeróbia e 3 horas para a fase aeróbia), a eficiência subiu para mais de 90% com DQO efluente abaixo dos 50 mg/L. A nitrificação ocorreu perto do 15° dia operacional do sistema combinado e estava praticamente estável ao fim dessa etapa operacional. Após o 20º dia de operação as concentrações de nitrito mantiveram-se sempre baixas, o que indica equilíbrio da nitrificação. Foram obtidos ganhos quando feita recirculação do efluente tratado, principalmente em relação à remoção de matéria orgânica (95%) e remoção de nitrogênio total que foi de 75% para razão de recirculação de 1,5. O reator avaliado apresentou estabilidade operacional, alta remoção de matéria orgânica e nitrogênio sem a necessidade de adição de fonte exógena de carbono e de suplementação de alcalinidade. / This work evaluated the performance of a system that combines anaerobic and aerobic processes, for treatment of domestic sewage. The bench-scale fixed-film reactor was operated in a continuous way without and with recycle of the liquid phase. Expanded clay and polyurethane foam were used as supports for immobilization of the biomass. Initially, the system was operated under anaerobic condition and its performance was evaluated for three different hydraulic retention times (HRT), 6, 8 and 10 h. In this phase, COD removal efficiency of 80% was reached for HRT of 10 h, with effluent COD below 150 mgCOD/L. The combined anaerobic-aerobic operation (HRT of approximately 11 h, being 8 h for the anaerobic phase and 3 h for the aerobic phase) favored the organic matter removal that reached 90%, with effluent COD below 50 mgCOD/L. The operation with liquid recycle provided the best results with COD removal of 95% and total nitrogen removal of 75% under recycle ratio of 1.5. The anaerobic-aerobic fixed bed reactor, with recycle of the liquid phase, proved to be an excellent alternative for domestic sewage treatment, mainly when organic matter and nitrogen removals are required. The concomitant C and N removal without addition of exogenous source electron donor and with no additional alkalinity supplementation was the main advantage of this reactor over the conventional reactors applied for this purpose.
23

Tratamento de esgoto sanitário em um reator de leito expandido em escala plena, operado com regiões anaeróbia e aeróbia sobrepostas / Treatment of sanitary wastewater in a full scale expanded bed reactor, operated with overlap anaerobic and aerobic regions

Silva, Rafael Ceribelli da 26 June 2009 (has links)
A presente pesquisa teve como objetivo principal a avaliação do desempenho de um reator de leito expandido (159,0 \'M POT.3\'), em escala plena, operado sob condições anaeróbia e anaeróbia-aeróbia sobrepostas, tratando esgoto sanitário. Como objetivos específicos, foi avaliado o uso de areias comerciais para complementação do leito de partículas, bem como a distribuição do material suporte ao longo da altura do reator. Além disso, houve a simulação da flotação do efluente do sistema a fim de otimizar a eficiência na remoção de sólidos, visto pela ineficiência do sistema na separação dos sólidos biológicos. Dentre os materiais selecionados para compor o leito de partículas, foi escolhida a areia com tamanho médio dos grãos igual a 0,69 mm e massa específica de 2690 kg.\'M POT.-3\'. Esta pesquisa foi dividida em duas etapas experimentais, sendo que a primeira o sistema foi operado somente sob a condição anaeróbia, enquanto na segunda, o sistema foi submetido à condição anaeróbia e aeróbia sobrepostas. Para a primeira etapa, o sistema obteve maior eficiência na remoção de matéria orgânica, com TDH de 14 horas, quando foi removido 0,84 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 1,26 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQObruta, DQOfilt, DBObruta, DBOfilt, SST e SSV foram de 65%; 64%; 80%; 70%; 58% e 69%. O efluente apresentou, em média, 245 mgDQObruta/L, 117 mgDQOfilt/L, 104 mgDBObruta/L, 76 mgDBOfilt/L; 88 mgSST/L e 69 mgSSV/L. O grau de amonificação obtido foi de 90%, evidenciando a potenciabilidade do sistema na conversão de matéria nitrogenado orgânico em amoniacal. Para a segunda etapa, a maior eficiência na remoção de matéria orgânica foi obtida com TDH de 16 horas, quando foi removido 0,29 kgDQObruta/\'M POT.3\'.dia, sendo que foi aplicado 0,84 kgDQObruta/\'M POT.3\'.dia. As eficiências médias de remoção de DQOfilt e DBOfiltr foram de 80% e 95%, respectivamente. O efluente apresentou, em média, 72 mgDQOfiltr/L, e 13 mgDBOfiltr/L. O grau de amonificação obtido foi de 85%, no entanto houve baixa eficiência na oxidação do \'N\'-amoniacal, no máximo 25%, sendo que as concentrações máximas no efluente foram de 4 mg\'N\'-\'NO IND.2\'POT.-\'/L e 2 mg\'NO IND.3\'POT.-\'/L, respectivamente. Em relação à distribuição do material suporte, foi verificada que a proporção de carvão ativado granular e carvão antracitoso foi superior em relação à areia, nos diferentes pontos de coleta, sendo que essa proporção tendeu a se reduzir ao longo das amostragens, além disso, foram verificadas que as características do fluxo não estão adequadas para proporcionar a fluidificação/expansão do leito de partículas. Os melhores resultados obtidos na simulação da flotação do efluente, quando foi aplicada recirculação com concentração de ar de 17,5 mgar/Lam, e velocidade ascensional de 10 cm/min. As eficiências de remoção de SST; SSF; SSV; DQO, cor e turbidez obtidas foram de 64; 82; 62; 62; 53 e 73%, respectivamente. O efluente flotado apresentou 63 mgSST/L; 5 mgSSF/L; 59 mgSSV/L; 127 mgDQObruta/L, 431 uC e 29 uT. / This present research had as main objective the evaluation of the performance of a full scale expanded bed reactor (159.0 \'M POT.3\'), operated under anaerobic and overlapping anaerobic-aerobic, treating sanitary wastewater. As specific objectives, it was evaluated using commercial sand to complement the bed of particles and distribution of material support along the height of reactor. Besides, it was simulated the flotation of the effluent system in order to optimize the efficient removal of solids, due to inefficiency of the system in the separation of biological solids. Among the materials selected to compose the bed of particles was chosen with the average size of sand grains equal to 0.69 mm and density of 2690 kg.\'M POT.-3\'. This research was divided into two experimental stages, the first being that the system was operated only under the anaerobic condition, while the second, the system was submited to anaerobic and aerobic conditions overlaped. For the first step, the system achieved greater efficiency in removing organic matter, with hydraulic detention time of 14 hours, when it was removed from 0.84 kgCODraw/\'M POT.3\'.day, which was applied 1.26 kgCOD/\'M POT.3\'.day. The mean removal efficiencies of DQOraw, DQOfiltered, BODraw, BODfiltered, TSS and VSS were 65%; 64%; 80%; 70%; 58% and 69%. The effluent had an average of 245 mgCODraw/L; 117 mgCODfiltered/L; 104 mgBODraw/L; 76 mgBODfiltered/L; 88 mgTSS/L and 69 mgVSS/L. The ammonification obtained was 90%, demonstrating the potencial of the system in the conversion of organic matter into ammonia nitrogen. For the second stage, the most efficient in the removal of organic matter was obtained with hydraulic detention time of 16 hours when it was removed from 0.29 kgCODraw/\'M POT.\'3.day, which was applied 0.84 kgCODraw/\'M POT.3\'.day. The mean removal efficiencies of CODfiltered and BODfiltered were 80% and 95%, respectively. The effluent had an average of 72 mgCODfiltered/L, and 13 mgBODfiltered/L. The ammonification obtained was 85%, however there was low efficiency in oxidation of ammonia-\'N\', at most 25%, and the maximum concentrations in the effluent were 4 mg\'N\'-\'NO IND.2\'POT.-\'/L and 2 mg\'N\'-\'NO IND.3\'POT.-\'/L, respectively. Regarding the distribution of material support, it was found that the proportion of activated granular carbon and anthracite carbon was higher on sand, in different points of collection, whereas this proportion tended to drop over the sample, moreover, was found that the characteristics of the flow are not adequate to provide fluidization/expansion of the bed of particles. The best results obtained in the simulation of the flotation of the effluent when it was applied with recirculation of air concentration of 17.5 mgair/Lsample, and ascension velocity of 10 cm/min. Removal efficiencies of TSS; FSS; VSS; COD, color and turbidity were obtained from 64; 82; 62; 62; 53 and 73%, respectively. The effluent had 63 mgTSS/L; 5 mgFSS/L; 59 mgVSS/L; 127 mgCODraw/L; 431 uC and 29 uT.
24

Estudo do desempenho de reator anaeróbio-aeróbio de escoamento ascendente no tratamento de esgoto sanitário com espuma de poliuretano como suporte de imobilização da biomassa / Study on the performance of an anaerobic-aerobic upflow reactor in the treatment of wastewater using polyurethane foam as a support for biomass immobilization

Sergio Brasil Abreu 27 June 2003 (has links)
O projeto consistiu na concepção e avaliação do desempenho de um sistema anaeróbio-aeróbio para tratamento de esgoto sanitário. O leito do reator foi dividido em quatro compartimentos de igual volume. Foi usada espuma de poliuretano para imobilização da biomassa e, para facilitar a partida do reator, esse material suporte foi previamente inoculado. O projeto teve três fases distintas: na primeira etapa, foi observada a importância da concentração de biomassa anaeróbia no desempenho de reator anaeróbio a princípio operado com metade do leito reacional com espuma e, a seguir, com o leito todo preenchido com espuma. Na segunda etapa, foram testados diferentes tempos de detenção hidráulica no reator que operou apenas em condições anaeróbias. Na última etapa foi operado o reator combinado anaeróbio-aeróbio. Ficou constatada a importância da concentração de microrganismos no desempenho do reator anaeróbio, pois com o aumento da quantidade de espuma, o reator atingiu resultados melhores e maior estabilidade operacional. Foi comprovada a influência do tempo de detenção hidráulica (TDH) no desempenho do reator. Tempos de detenção muito altos acarretam problemas de transferência de massa líquido-sólido, e baixos TDH dificultam adequada ação dos microrganismos. O melhor resultado para o reator em operação exclusivamente anaeróbia foi para o TDH de 10 horas, no qual se conseguiu reduzir a DQO de amostra bruta de 389 +/- 70 mg/L para 137 +/- 16 mg/L, em média. Para o reator operado anaeróbio-aeróbio a DQO de amostra bruta decresceu de 259 +/- 69 mg/L para 93 +/- 31 mg/L, em média. A comparação de todos os resultados obtidos, evidenciou a importância do pós-tratamento aeróbio na remoção de parcela de matéria orgânica não removida em tratamento unicamente anaeróbio. / The project consisted in the design and performance evaluation of an anaerobic-aerobic system for wastewater treatment. Polyurethane foam was used for biomass immobilization and, to smooth the reactor start-up, this supporting material was previously inoculated. The project was divided in three distinct phases. In the first one, the importance of the anaerobic biomass concentration was observed in the performance of the anaerobic reactor in a way to operate the reactor primarily with half of the reaction bed filled with foam and subsequently operate it with the bed completely filled with foam. In the second phase, different times of hydraulic retention were tested with the reactor operating exclusively in anerobic conditions. In the third and last phase, an anaerobic-aerobic combined reactor was operated. It was possible to confirm the importance of microorganism concentration in the performance of the anaerobic reactor, since the increase in the amount of foam allowed the reactor to reach better results and greater operational stability. The influence of the hydraulic retention time in the reactor performance was also proved. Very high retention times cause problems in the liquid-solid mass transference, while low retention times do not allow an adequate action of microorganisms. The best result for the reactor with an exclusive anaerobic operation was the 10 hour retention time, when it was possible to reduce the COD of a 389 +/- 70 mg/L gross sample to a 137 +/- 16 mg/L in average. On the other hand, for the anaerobic-aerobic operating reactor, the COD of a gross sample dropped from 259 +/- 69 mg/ L to 93 +/- 31 mg/L in average. Finally, comparing all the obtained results, it was possible to verify the importance of the anaerobic post treatment in the removal of a part of the organic matter not removed in an exclusively anaerobic treatment.
25

Reator anaeróbio-aeróbio de leito fixo em escala piloto, com recirculação da fase líquida, aplicado ao tratamento de esgoto sanitário / Anaerobic-aerobic pilot-scale fixed-bed reactor, with recycle of the liquid phase, applied to the treatment of domestic sewage

Antonio Pedro de Oliveira Netto 29 April 2011 (has links)
Este trabalho fundamentou-se na concepção, desenvolvimento tecnológico, ampliação de escala e avaliação do comportamento de sistema combinado anaeróbio-aeróbio de leito fixo e fluxo ascendente, com recirculação da fase líquida, para tratamento de esgoto sanitário. O reator, em escala piloto, foi construído em formato cilíndrico e confeccionado em fibra de vidro com volume total de aproximadamente 2,5 \'M POT.3\', com intuito de desenvolver um sistema capaz de operar como única unidade de tratamento para remoção de matéria orgânica e nitrogênio, reduzindo a geração de lodo e o consumo de energia pela combinação dos processos anaeróbio e aeróbio, possibilitando o aproveitamento das vantagens de cada um e minimizando seus aspectos negativos. Os melhores resultados operacionais foram encontrados para a etapa com tempo de detenção hidráulica total (TDH) de 12 horas e razão de recirculação (r) igual a 3,0, apresentando eficiências médias de remoção de DQO, \'N\'-NTK e SST de 92 ± 3%; 68 ± 11% e 75 ± 7%, respectivamente, com valores médios efluentes de 54 ± 22 mgDQO/L, 14 ± 10 mg \'N\'-NTK/L e 70 ± 42 mgSST/L. Os valores médios de carga orgânica volumétrica (COV) e carga volumétrica de nitrogênio (CVN) removidas foram de 1,08 ± 0,04 kgDQO/\'M POT.3\'.dia e 0,06 ± 0,02 kgNTK/\'M POT.3\'.dia para esta etapa. A estabilidade operacional durante a etapa com TDH de 12 h, a alta remoção de matéria orgânica e nitrogênio, sem a necessidade de adição de fonte exógena de carbono, para promover o processo de desnitrificação, e de suplementação de alcalinidade consumida durante a nitrificação, e a reduzida necessidade de manutenção devido à tecnologia de fabricação adotada, comprovam a viabilidade técnica de utilização do reator combinado de leito fixo como unidade compacta para pequenas comunidades ou vazões afluentes, para tratamento de esgoto sanitário. / This work was based on design, technology development, scale up and performance evaluation of an up-flow combined anaerobic-aerobic fixed bed system, with recycle of the liquid phase, for treatment of domestic sewage. The pilot scale reactor was built in a fiberglass cylindrical shape with a total volume of approximately 2.5 \'M POT.3\', aiming at the development of a system capable of operate as a single treatment unit for organic matter and nitrogen removal, with low sludge production and energy consumption by the advantages of combination of anaerobic and aerobic processes. The improved operating results were found for the condition with overall hydraulic retention time (HRT) of 12 hours and recycle ratio (r) equal to 3.0, with average removal efficiencies of COD, TKN and TSS of 92 ± 3%, 68 ± 11% and 75 ± 7%, respectively, with average effluent values of 54 ± 22 mgCOD/L, 14 ± 10 mgTKN/L and 70 ± 42 mgTSS/L. The average values of removed organic loading rate (OLR) and nitrogen volumetric loading (NVL) reached 1.06 ± 0.04 kgCOD/\'M POT.3.d and 0.06 ± 0.02 kgTKN/\'\'M POT.3\'.d for this phase. The operational stability during the stage with HRT of 12 h, the high organic matter and nitrogen removal, without addition of exogenous carbon source (electron donor) to promote the denitrification process, with no supplementation of alkalinity consumed during nitrification, and the reduced maintenance due to manufacturing technology adopted, proved the technical feasibility of the combined fixed-bed reactor as a compact unit for small communities or low inflow rates, for treatment of domestic sewage.
26

Determinação do gradiente de pressão estática do ar para sistemas de compostagem por aeração forçada / Determination of static pressure gradient of air for composting system by forced aeration

Teixeira, Denis Leocádio 18 July 2014 (has links)
Made available in DSpace on 2015-03-26T13:23:59Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1263079 bytes, checksum: 4f8dcc7d9121a93cc4f882cd8390c608 (MD5) Previous issue date: 2014-07-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Although there equations and graphics in scientific literature to estimate the static pressure gradient of airflow through layers of grains and seeds, studies using organic waste submitted to composting treatment are scarce. The objective of this study was to adjust equations to estimate the static pressure gradient of airflow through layers of different organic residues. The waste used were chicken litter and as bulking agents and carbon source: sugarcane bagasse, sawdust and coffee husk which were mixed in the ratio of 0; 10; 20; 30 e 40% (volumetric basis), of chicken litter in relation to bulking agents, as well as mixture with C/N ratio of 25/1, which were submitted to composting process. Measurements of static pressure drop in layers of organic waste before and after the composting process, and in layers of material from the different proportions of chicken litter added to bulking agents, were performed using a prototype with specific airflow rates ranging from 0.02 to 0.13 m 3 s -1 m -2. The static pressure drop of airflow increased as a power of the material layer thickness. Static pressure gradient in layers of organic waste decrease with the composting process. Shedd, Hukill & Ives and Hunter models may be used to predict the static pressure gradient of air to be blown through the organic residues layers, however, the Shedd model was that which best represented the phenomenon studied. Lower values of static pressure gradient were obtained in layers without chicken litter and the higher values obtained in layers composed of mixture of chicken litter in proportion of 40%. Equations to estimate the static pressure gradient for different proportions of chicken litter may be clustered, yielding models that can explain the variation of pressure gradient for each bulking agent and carbon source. / Embora existam, na literatura científica, equações e gráficos para estimativa do gradiente de pressão estática do ar, quando forçado em camadas de grãos e sementes, são poucos os trabalhos realizados utilizando-se resíduos orgânicos submetidos ao tratamento por compostagem. Neste trabalho, teve-se por objetivo o ajuste de equações que possibilitassem a estimativa do gradiente de pressão estática do ar, quando insuflado em camadas de diferentes materiais orgânicos. Os resíduos utilizados foram a cama de frango e, como agentes estruturantes e fonte de carbono, o bagaço de cana-de-açúcar, a serragem de madeira e a palha de café, os quais foram misturados nas proporções de 0; 10; 20; 30 e 40% (base volumétrica) de cama de frango em relação aos agentes estruturantes, além de misturas com relação C/N de 25/1, as quais foram submetidas ao tratamento por compostagem. As medições da queda de pressão estática do ar, ao atravessar camadas de material orgânico, antes e depois de ter sido submetido ao tratamento por compostagem, e nas camadas de materiais provenientes das diferentes proporções de cama de frango adicionada aos agentes estruturantes, foram realizadas utilizando-se um protótipo, no qual o material foi submetido a vazões específicas de ar que variaram de 0,02 a 0,13 m 3 s -1 m -2 . A queda na pressão estática do ar aumentou de forma potencial com a espessura da camada de material. No que se refere ao decurso do processo de compostagem, este contribuiu para redução do gradiente de pressão estática do ar ao atravessar as camadas de material orgânico. Os modelos matemáticos de Shedd, Hukill & Ives e Hunter podem ser utilizados para predizer o gradiente de pressão estática do ar, ao ser insuflado em camadas de resíduos orgânicos, no entanto, o modelo de Shedd pode ser considerado, em termos estatísticos, o que melhor representou o fenômeno em estudo. Menores valores de gradientes de pressão estática do ar foram obtidos em camadas sem adição de cama de frango e os maiores obtidos nas camadas constituídas pela mistura com cama de frango na proporção de 40%. As equações obtidas para estimativa do gradiente de pressão estática do ar, para as diferentes proporções de cama de frango, podem ser agrupadas, originando modelos capazes de explicar a variação do gradiente de pressão para cada agente estruturante e fonte de carbono.

Page generated in 0.0916 seconds