• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • Tagged with
  • 26
  • 26
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Custos energéticos e econômicos do agroecossistema milho em consórcio com pinhão-manso

Frigo, Michelle Sato [UNESP] 11 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-11Bitstream added on 2014-06-13T19:42:01Z : No. of bitstreams: 1 frigo_ms_dr_botfca.pdf: 918232 bytes, checksum: 5a31eb1dab6ae0414c4294ca6e5b0941 (MD5) / O conhecimento da produção e dispêndio de energia pela agricultura é fundamental devido à importância estratégica que ocupa como produtora de insumos energéticos para outros setores econômicos, como é o caso do biodiesel produzido a partir de culturas oleaginosas; desta forma o presente estudo teve como objetivo determinar os custos parciais da implantação e condução do agroecossistema milho em consórcio com pinhãomanso, sob três diferentes sistemas de condução (sequeiro, irrigado e fertirrigado com água residuária da suinocultura) do ponto de vista energético e econômico, em experimento conduzido de acordo com o sistema produtivo da agricultura familiar da região oeste do Paraná. Tal estudo se justifica devido à escassez de dados tanto energéticos como econômicos da cultura do pinhão-manso em condições brasileiras, bem como em sistema consorciado sob condições tecnológicas da agricultura familiar do oeste paranaense e, sobretudo das questões ambientais envolvidas neste estudo como o reuso de águas e o uso racional de fontes energéticas não-renováveis. O experimento foi conduzido de acordo com as técnicas empregadas por agricultores familiares da região oeste paranaense, no período de fevereiro de 2008 a maio de 2008 para a cultura do milho e de fevereiro de 2008 a novembro de 2009, para a cultura do pinhão-manso, no Núcleo Experimental de Engenharia Agrícola (NEEA), pertencente à Universidade Estadual do Oeste do Paraná (UNIOESTE), campus de Cascavel/PR... / Knowledge of production and energy expenditure in agriculture is crucial due to strategic importance which occupies as a producer of energy inputs to other economic sectors, such as biodiesel produced from oilseed crops, so this study aimed to determine partial costs of deployment and conduct of corn intercropping agroecosystem with physic nut, under three different management systems (rainfed, irrigated and fertirrigated with wastewater from pig farming) in terms of energy and economic experiment carried out in accordance with the productive system of family farming in the west of Paraná. Such a study is justified due to the shortage of both energy and economic data of the culture of physic nut under Brazilian conditions, as well as in intercropping system under technological conditions of the family farm west of Paraná, and especially environmental issues involved in this study as the reuse of water and the rational use of nonrenewable energy sources. The experiment was conducted in accordance with the techniques employed by farmers in the region, from February 2008 to May 2008 for corn and from February 2008 to November 2009 for the cultivation of physic nut in Experimental Center of Agricultural Engineering (NEEA), belonging to the State University of West Paraná (UNIOESTE), campus of Cascavel/PR, in the area of no-tillage. The itinerary for all technical training systems consisted of: the site preparation (application of desiccant), mechanized planting of corn, corn plant by hand, production of seedlings of physic nut, coveamento and transplant seedlings of physic nut, mowing manual, manual application of insecticide and harvesting of maize, differing only by irrigation and fertirrigation. The final product was assessed only corn. The technical coefficients, the workload, performance, identification of the tractor... (Complete abstract click electronic access below)
2

Reuso de efluentes no processo industrial de siderurgia

Santos, Anderson Baptista dos [UNESP] 16 January 2014 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-16Bitstream added on 2014-08-13T18:00:43Z : No. of bitstreams: 1 000755517_20160116.pdf: 165609 bytes, checksum: ab61e84e3da50b0a1ba379151fbf73fe (MD5) Bitstreams deleted on 2016-01-18T10:44:02Z: 000755517_20160116.pdf,. Added 1 bitstream(s) on 2016-01-18T10:44:39Z : No. of bitstreams: 1 000755517.pdf: 2280921 bytes, checksum: 48917e8b4317c8508e95a16c295a5cb2 (MD5) / O uso da água e consequentemente seu reúso são temas que tem ganhado destaque no mundo. Este trabalho analisou algumas possibilidades de reúso do efluente gerado em uma planta siderúrgica, especificamente em uma estação de tratamento de água de uma laminação que capta água do rio Paraíba do Sul e descarta os efluentes no ribeirão dos Surdos. Neste estudo analisou-se ainda a necessidade de adequação do efluente gerado para atender ao CONAMA 357/2005, CONAMA 430/2011 e Decreto 8.468/1976 visto que o ribeirão que recebe o efluente possui baixa vazão. Este fato exige o tratamento do efluente para atender aos parâmetros de qualidade de lançamento e faz com que eles sejam menores que os previstos nas resoluções e decretos. Ao tratar o efluente identificou-se que é possível aplicá-lo como reúso em vez de simplesmente descartá-lo. O trabalho apresentou os desafios para a aplicação do reúso em indústrias que produzem a própria água potável. Ao comparar as tarifas cobradas pela SABESP, na região do Vale do Paraíba, e o custo de produção interno da água. Nota-se que a água produzida na própria indústria pode ter um custo 8 vezes menor que a fornecida por terceiros. Então somente os trabalhos com pequenos investimentos conseguem tornar-se viáveis. Como é o caso do reúso em lavagem de pisos, resfriamento de escória, reúso em vasos sanitários e mictórios, que apresentaram retorno perto de cinco anos / The use of water and consequently its reuse are receiving a lot of attention around the World. This report has analyzed some possibilities for reusing the flowing out of a metallurgical company, specifically in a water treatment station from a rolling mill which receives the water from the Paraiba do Sul river and the effluents is discharged in the Surdos river. This report has also analyzed the need of adjustment to attend CONAMA 357/2005, CONAMA 430/2011 and Decree 8.468/1976 once the stream which receives this effluent has a low flow. Because of this, the treatment for this effluent has to obey strict parameter of quality, and the disposal has to be lower than the values fixed in the resolutions and decrees. While treating the effluent we have identified the possibility for reuse instead of just dismiss. The task has presented some challenges to the reuse application in industries that produce its own potable water. To compare the tax charged by SABESP, in Vale do Paraíba region, and the cost of internal water production has a 8 times difference in cost. Then only small work with low investment can became viable. As in the case of reusing water to wash the floor, scrap cooling, reuse in toilets and urinal, showing return only after five years
3

Estudo do reúso não potável de água de processo e efluente tratado em indústria de bebidas

Galvão, Michel Ribas 15 June 2011 (has links)
Resumo:O rigor da legislação atual sobre o processo de outorga e cobrança de captação de água e lançamento de efluente tratado, além da perda e desperdício de água durante o processo produtivo, exige das indústrias soluções alternativas para o reúso de água e efluentes, visando a redução do uso de recursos naturais. O reúso não potável da água de processo possibilita uma menor dependência da utilização da água captada pela concessionária pública responsável pelo abastecimento da região. Uma das vantagens deste tipo de reúso é a economia de custos gerada no processo produtivo, diminuindo assim a quantidade de efluente tratado lançado no corpo hídrico receptor. O objetivo deste trabalho é estudar as possibilidades de reúso não potável de água de processo, bem como, pesquisar um sistema alternativo de desinfecção do efluente tratado a fim de que o efluente possa ser reutilizado. Dessa forma, a empresa pode ser reconhecida em relação à responsabilidade social e ambiental, já que estará economizando recursos naturais e melhorando os resultados dos indicadores ambientais estabelecidos por essa companhia. Foram realizados testes de bancada com o dióxido de cloro, visando um novo sistema de desinfecção para que fosse possível reutilizar futuramente esse efluente. Foram realizados testes para reúso de água do processo de tratamento de água, utilizando um bag, que possui como propriedade característica, separar os sólidos do meio aquoso. Por último, foram realizados dois projetos de reúso não potável de água de processo. Os resultados obtidos quanto ao poder germicida do dióxido de cloro foram satisfatórios. Os objetivos de preservação dos recursos naturais e melhoria dos indicadores ambientais da companhia foram atingidos com a realização dos dois projetos de reúso não potável de água de processo. Os testes de reúso de água utilizando o bag separador de partículas sólidas não foram satisfatórios tendo em vista as características do bag utilizado.
4

Avaliação qualitativa da água residuária de abatedouro de aves para fins de reúso em irrigação

Minghini, Israel [UNESP] 20 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-20Bitstream added on 2014-06-13T19:14:05Z : No. of bitstreams: 1 minghini_i_me_botfca.pdf: 448467 bytes, checksum: b2a4f494cb357e662adbf52c2039ccbb (MD5) / O objetivo do presente trabalho consistiu na avaliação de parâmetros de qualidade da água residuária proveniente de abatedouro de aves, visando analisar a possibilidade de reutilizá-la na irrigação de culturas agrícolas, após sua caracterização. As águas residuárias do abatedouro de aves, localizado na cidade de Pereiras – SP, foram coletadas em diferentes dias e épocas do ano e analisadas quanto aos seguintes parâmetros: pH, temperatura, condutividade elétrica, fósforo total, nitrato, nitrito, sólidos sedimentáveis, ferro, alumínio, turbidez, Salmonellas sp, macro e micronutrientes. As temperaturas do ar e da água foram medidas no momento da coleta.A discussão dos resultados obtidos esteve de acordo com a Resolução do Conselho Nacional do Meio Ambiente (CONAMA) nº 357, de 17 de março de 2005, que estabelece os padrões para classificação dos corpos de água. A condutividade elétrica foi avaliada segundo padrões propostos pela Companhia de Tecnologia de Saneamento Básico (CETESB, 2005) e o alumínio, segundo valor estabelecido pelo Ministério da Saúde – Portaria nº 1 469. Os resultados obtidos permitem concluir que a água residuária analisada, não deve ser descartada diretamente em corpos hídricos naturais, porém, pode ser utilizada na irrigação de culturas agrícolas, após simples desinfecção. / The aim of this search consisted in comparing the quality of wastewater from a poultry slaughterhouse, trying to analyze the possibility of using it in the irrigation of agricultural growing, after its make-up. Samples were colleted from wastewater from a poultry slaughterhouse in Pereiras – SP, in different days or time of the year, analyzing the following: pH, temperature, electrical conductivity, total phosphorus, nitrate, nitrite, sedimentary solids, iron, aluminium, muddy, salmonella, macro and micro nutrients. The temperature of the air and of the water were measured at collection time.The results were evaluated according to the Resolution of the Environment National Council (CONAMA) nº 357, on March 17th- 2005, which establish the patterns to classify the water contents. The electrical conductivity was evaluated according to the amount suggested by CETESB/2005 and the aluminium according to the established amount by Health Ministry – Regulation nº 1.469. The obtained results allow to conclude that the analyzed wastewater, must not be rejected in natural water contents, however, it can be used in the irrigation of agricultural growing, after simple disinfection.
5

Avaliação do potencial de reuso agrícola do efluente de uma estação de tratamento de esgoto com alagados construídos

Giafferis, Giselda Passos [UNESP] 11 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-11Bitstream added on 2014-06-13T20:42:20Z : No. of bitstreams: 1 giafferis_gp_dr_botfca.pdf: 2278528 bytes, checksum: bc34acd935bbc156fa3e47bced1d5556 (MD5) / Os sistemas de alagados construídos (SACs) são projetados como passivos de depuração, constituídos por lagoas ou canais, compostos por plantas aquáticas livres ou fixas em substratos como areia, solo ou cascalho, onde ocorre a proliferação de biofilmes que agregam populações variadas de micro-organismos presentes nas águas residuárias. O uso combinado de tecnologias simples e de baixo custo como os reatores anaeróbios seguidos de alagados construídos como pós-tratamento, tem sido de interesse para o saneamento em pequenas comunidades. A pesquisa ocorreu em uma planta de tratamento de esgoto real do Departamento de Água e Esgoto de Bauru, localizada no Distrito de Tibiriçá, com vazão média de 4,8L/s, composta por processo de filtro anaeróbio de fluxo ascendente, seguido de sistemas de alagados construídos em paralelo. Como objetivo deste trabalho, buscou-se avaliar a eficiência dos três sistemas de alagados construídos, com tipos de plantas diferentes e analisar quantitativa e qualitativamente os efluentes nas várias etapas do processo de tratamento, para verificar suas eficiências e a possibilidade de reúso do efluente final na agricultura. Diante dos resultados obtidos, observou-se que houve satisfatória remoção de matéria orgânica, com concentração média de 36 e 39 mg/L, nas fases 1 e 2 de operação,respectivamente, atendendo os valores exigidos pela legislação para padrões de emissão, mesmo recebendo concentrações afluentes elevadas, de efluentes não doméstico por batelada, o qual não foi previsto em projeto. Constatou-se que as concentrações de nutrientes, como nitrogênio e fosfato foram altas em todo o sistema e a eficiência de remoção de nitrogênio amoniacal esteve muito abaixo do esperado, não atendendo a legislação que exige lançamentos... / The constructed wetland systems are designed as passive purification, consisting of ponds or channels, composed of aquatic plants free or fixed on substrates such as sand, soil or gravel, where the proliferation of biofilms is that aggregate diverse populations of micro- organisms present in wastewater. The combined use of simple and inexpensive as the anaerobic reactors followed by constructed wetlands as post-treatment has been of interest for sanitation in small communities. The research took place in a sewage treatment plant's actual Department of Water & Sewer Bauru, located in the District of Tibiriçá with average flow of 4.8 L/s made by a process of upflow anaerobic filter, followed by systems constructed wetlands in parallel. As objective of this study we sought to evaluate the effectiveness of three constructed wetland systems, with different types of plants and analyze quantitative and qualitative effluent at various stages of treatment to monitor their effectiveness and the possibility of reuse in the final effluent agriculture. Considering the results obtained, it was observed that there was satisfactory removal of organic matter, with a mean concentration of 36 and 39 mg/L, phases 1 and 2 operations, respectively, given the values required by law for emission standards, even with affluent high concentrations of non-domestic waste per batch, which was not foreseen in the project. It was found that concentrations of nutrients such as nitrogen and phosphate were high throughout the system and the removal efficiency of ammonia nitrogen was much lower than expected, does not meet the law requires that releases up to 20 mg/L. The results obtained for nitrogen and phosphate in effluent from constructed wetland systems, it is concluded that the system is also functioning as a secondary... (Complete abstract click electronic access below)
6

Efeito da água residuária da suinocultura no solo e na cultura do milho

Prior, Maritane [UNESP] 22 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-22Bitstream added on 2014-06-13T20:26:50Z : No. of bitstreams: 1 prior_m_dr_botfca.pdf: 609810 bytes, checksum: 6b9456e563b46b7994e59d010c70f78f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Universidade Estadual Paulista (UNESP) / A região Oeste do Paraná é grande produtora de suínos, devido a isso, tem-se tornado um problema sério o grande número de dejetos líquidos gerados por essa atividade, além de ser considerada como causadora de degradação ambiental. O uso da água residuária de suinocultura (ARS) vem sendo aplicado ao solo como forma de adubação em várias culturas, o que melhora as condições do solo devido ao fornecimento de nutrientes, além de economizar custos com fertilização e água potável. Entretanto, a utilização da ARS na agricultura pode causar problemas, quando realizada de forma inadequada, devido à falta de informações sobre a taxa de aplicação adequada. Neste contexto, este trabalho teve por objetivo quantificar elementos e variáveis no solo e lixiviado quanto aos parâmetro físicos e químicos, bem como avaliar o comportamento da cultura em função da aplicação de água residuária de suinocultura (ARS) em um Latossolo Vermelho Distroférrico típico cultivado com milho. O experimento foi conduzido em ambiente protegido, onde foram construídos 24 lisímetros de drenagem, que receberam água residuária de suinocultura (ARS), sendo aplicadas cinco taxas de ARS (0; 112,5; 225; 337,5 e 450 m3 ha-1 no ciclo), combinadas com duas adubações de solo (50 e 75%), em três repetições por tratamento, sendo distribuídas em cinco aplicações durante o ciclo da cultura. Fez-se irrigações de acordo com a precipitação média ocorrida no período, quinzenalmente, resultando em seis coletas do material lixiviado, que foi analisado quanto ao N total, NO3 -, NO- 2, pH, CE, Ca, Mg, Na, K e P. Durante o ciclo da cultura do milho foram coletadas cinco amostras de solo de cada uma das parcelas analisadas quanto ao N total, N orgânico, N inorgânico, NH4 +, NO3 -, Na, pH, CE, MO, P, Ca, Mg, K, V%, CTC, P, Cu, Fe, Mn e Zn. Para o comportamento da cultura foi avaliado o diâmetro... / West of Paraná is a big producer of swine, due to that, it has been turning a serious problem the great volume of liquid dejections generated by this activity, besides it is considered as responsible of environmental degradation. The use of the swine wastewater (ARS) has been applied to the soil as a manuring form in several cultures, that improves the conditions of the soil due to the supply of nutrients, besides saving costs with fertilization and drinking water. However, the use of ARS in the agriculture can cause problems, once the application is made in an inadequate way, due to the lack of information about the appropriate rate of application. In this context, this work had for objective to evaluate the effects caused in the soil and leached as for the parameters physicists and chemical, as well as to evaluate the behavior of the culture in function of the swine wastewater application (ARS) in a Typical Dystroferric Red Latosol cultivated with corn. The experiment was driven in protected atmosphere, where 24 drainage lisimiters were built, that received swine wastewater (ARS), where it was applied five rates of ARS (0; 112,5; 225; 337,5 and 450 m3 ha-1 in the cycle), combined with two soil manurings (50 and 75%), in three repetitions for treatment, where it was distributed in five applications during the cycle of the culture. It was made irrigations in agreement with the medium precipitation happened in the period, biweekly, resulting in six collections of the leached material, that it was analyzed as for total N, NO3, NO2, pH, CE, Ca, Mg, Na, K and P.
7

Ozonizaçãoe peroxização de efluente sanitário proveniente de alagados construídos e reator compartimentado anaeróbio/aeróbio visando reuso / Ozonation and peroxidation of sanitary effluent from constructed westlands and anaerobic baffled reactor/aerobic aiming reuse

Miranda, Nathalie Dyane [UNESP] 02 July 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:49Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-02Bitstream added on 2015-03-03T12:07:00Z : No. of bitstreams: 1 000801776.pdf: 1407087 bytes, checksum: 6fe16dd172219fd42fef9b040a788666 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta pesquisa teve por objetivo principal estudar a desinfecção de esgoto sanitário proveniente do tratamento de uma nova configuração de um reator compartilhamentado aneróbio/aeróbio e de alagados construídos, utilizando o ozônio e peroxônio. Avaliaram-se como estes atuam no processo de oxidação e inativação de coliformes totais e Escherichia coli, comparando suas eficiências e a formação do formaldeído, que é principal aldeído formado durante a aplicação de ozônio e peroxônio para desinfecção. A formação de formaldeído foi fortemente da dose de ozônio, porém um tempo de contato maior também favoreceu uma maior formação de formaldeído, mesmo que não significativa segundo os testes estatísticos aplicados. Os ensaios de peroxização com uma dose de 5 mg O3 L-1 promoveram uma média de formação de formaldeído maior que quando apenas aplicando somente a mesma dose de ozônio. Com uma dose de 8 e 10 mg O3 L-1, a formação de formaldeído foi em geral menor que quando aplicada durante somente a mesma dose de ozônio. Ou seja, doses maiores de ozônio durante a peroxização favoreceram uma menor concentração de formaldeído no efluente final. Todos os ensaios de ozonização e peroxização promoveram concentrações de formaldeído que estavam dentro do limite imposto pela OMS (água potável). Tanto para o efluente proveniente dos A.C. quanto do reator compartimentado, doses maiores de ozônio ou um tempo de contato maior não favoreceu uma inativação significativamente maior. A inativação de E. coli, no efluente proveniente do reator compartilhamentado, não foi superior ao se adicionar peróxido de hidrogênio. Já a inativação de coliformes totais foi na maioria dos testes superior aos resultados encontrado quando aplicado somente ozônio, sendo que o consumo de ozônio durante a peroxização foi menor que na ozonização. Pode assim concluir que a adição de peróxido de hidrogênio foi à... / This research was aimed to study the disinfection of wastewater from treatment by a new configuration of an anaerobic/aerobic baffled reactor and by constructed wetlands, using ozone and peroxone. Were avaluated how these processes acted in the oxidation and inactivation of total coliforms and Eschechia coli, comparing their efficiency and formation of formaldehyde, which is the main aldehyde formed during the application of ozone and peroxone for disinfection. The formation of frmaldehyde was strongly depend on the dose of ozone, by a longer contact time also favored an increased in the formation of formaldehyde, even not significant according to the statistical tests applied. Peroxidation tests with a dose of 5 mg O3L-1 promoted a higher average formation of formaldehyde than when applying only just the same dose of ozone. For doses of 8 and 10 mg O3L-1, the formation of formaldehyde was generally smaller than when applied just the same dose of ozone. I.e., higher ozone doses during peroxidation favored a lower formaldehyde concentration in the final effluent. All tests ozonation and peroxidation promoted formaldehyde concentrations that were within the limit imposed by WHO (drinking water). For both the effluent from the C.W. as the anaerobic/aerobic baffled reactor, higher ozone doses or a longer contact time did not favor a significantly higher inactivation. Inactivation of Escherichia coli in effluent from the anaerobic/aerobic baffled reactor was no better when added hydrogen peroxide. The inactivation of total coliforms was higher in most of the tests when applied just ozone, and the consumption of ozone during peroxidation was lower than in ozonation tests. This way, is possible to conclude that the addition of hydrogen peroxide was favorable to the inactivation of total coliforms. For the effluent from the anerobic/aerobic baffled reactor only with the application of ozone was required a dose of 8 mg O3 L-1 for the effluent... / FAPESP: 11/10816-2
8

Avaliação do desempenho de gotejadores com uso de água residual na suinocultura / Development evaluation of dripper with swine wastewater

Franco, Daniel [UNESP] 18 September 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-18. Added 1 bitstream(s) on 2015-12-10T14:28:38Z : No. of bitstreams: 1 000853170.pdf: 1637274 bytes, checksum: 8870536067ed0c31cebcec62103500bc (MD5) / O objetivo do presente trabalho foi de avaliar a uniformidade de aplicação de água utilizando o coeficiente de uniformidade de distribuição (CUD), coeficiente de uniformidade de Christiansen (CUC) e o coeficiente de uniformidade estatístico (CUE), além de determinar o coeficiente de variação de vazão (CVQ) utilizando o tubo gotejador da marca Netafim modelo Streamline 16060, após seu uso com água residuária oriunda da suinocultura. O experimento foi conduzido no Laboratório de Irrigação da UNESP-FCA, Campus de Botucatu-SP. Foi executado em uma bancada de ensaio de gotejadores, utilizando quatro segmentos do tubo gotejador com 6 metros, e escolhidos 32 emissores, onde se verificou a vazão destes emissores com as seguintes pressões: 45, 55, 65, 78 kPa, com quatro repetições para cada gotejador. Após os ensaios, o tubo gotejador foi submetido a 600 horas de trabalho com água residuária oriunda da suinocultura. Foram realizados os mesmos ensaios com o tubo gotejador novo com, 100, 200, 300, 400 e 500 horas de trabalho com água residuária. Os valores obtidos com o tubo novo e após seu uso durante 400 horas com água residuária da suinocultura para o CVQ foram classificados como bons, pela tabela da ABNT (1987). Já quando se atingiu 500 horas de trabalho as pressões 45 e 65 kPa apresentaram um CVQ de 0,5 considerado médio pela ABNT (1987) e com 600 horas de trabalho as avaliações em todas pressões foram classificadas como médio. O CUD, CUC, e o CUE, desde o ensaio inicial e até 600 horas de trabalho na bancada, foram considerados como excelentes, de acordo com Merriam & Keller (1978), apesar de alguns gotejadores ao longo do tempo apresentarem obstruções parciais. Porem com o passar do tempo o CUD e o CUE apesar de serem classificados como excelentes apresentaram um leve declínio em seus valores. Com base nos resultados obtidos, foi possível concluir que, após 600 horas... / The aim of the present work was to evaluate the application uniformity of water using the distribution uniformity coefficient (DU), Christiansen uniformity coefficient (UC) and statistical uniformity coefficient (SUC), besides determine the flow variation coefficient (FVC) using a Netafim brand 16060 Streamline model dripper tube, after its use with swine wastewater. The The experiment was done in Irrigation Laboratory of UNESP-FCA, Botucatu-SP campus. It have done in a dripper test bench using four sections of 6 meters dripper tubes, 32 emitters chosen, where the flow verified in the emitters was the following pressure: 45, 55, 65, 78kPa, with four repetitions for each dripper. After the test, the dripper tube was subordinated to 600 hours work with swine wastewater. It have done the same tests with the new dripper tube with 100, 200, 300, 400 and 500 hours of work with residual water. The obtained values with the new tube and after its use through 400 hours with swine wastewater for FVC were classified as good by ABNT chart (1987). Nevertheless, when reached 500 hours of work, the pressures 45 and 65 kPa show a FVC of 0.5 considerate medium by ABNT (1987) and with 600 hours of work, the evaluation in all pressures were classified as medium. The DU, UC and SUC, since initial test to 600 hours of work in bench were classified as excellent, according to Merriam & Keller (1978), despite of some drippers show partial obstruction through time. However, through the time, the DU and UC besides classified as excellent show a small decline in their values. Based in the obtained results, it is possible to conclude that after 600 dripper tube hours of use, the dripper keep satisfactory water application uniformity, the test showed the possibility of swine wastewater for dripper irrigation, without dripper obstruction problems in periods until 600 hours of use. For swine wastewater use in irrigation projects ...
9

Estimativa da correção do coeficiente de retorno de esgoto sanitário em habitações com sistemas de aproveitamento de água pluvial: estudo de caso da cidade de Bauru (SP)

Leão, Cintia Loturco Pinheiro [UNESP] 16 July 2015 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:27:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-16. Added 1 bitstream(s) on 2016-01-13T13:32:42Z : No. of bitstreams: 1 000854108.pdf: 5586364 bytes, checksum: d568996f1a6d163ef9f00b23a62fa6df (MD5) / Vário estudos têm sido realizados propondo técnicas de conservação de água, visando minimizar o consumo de água tratada. Dentre eles destaca-se o aproveitamento de água pluvial em atividades que possam prescindir da potabilidade. No Brasil, a cobrança dos serviços de coleta e tratamento de esgoto sanitário, em geral, é realizada com base no volume de água tratada medida do hidrômetro da unidade consumidora. Portanto, esse descarte de esgoto gerado pelo sistema de aproveitamento de água pluvial não é contabilizado pelo sistema de tarifação de esgoto no custo de destinação e tratamento. A utilização dessa água pluvial subestima o volume de esgoto gerado. Este trabalho propõe a aplicação da metodologia para o ajuste desse coeficiente de retorno visando estimar o volume de água pluvial lançado na rede coletora de esgoto indexado ao volume de água tratada medido no hidrômetro de cada unidade consumidora. A bacia sanitária com caixa acoplada foi adotada como objeto de estudo. A partir da coleta de amostragens de áreas de telhado do município de Bauru (SP), determinou-se a área média de telhado. Diferentes simulações de determinação de áreas de telhado, volumes de reservatórios e demandas de consumo de água foram realizadas, com o intuito de analisar o comportamento do ajuste do coeficiente de retorno para a área média de telhado per capita (m2.hab-1). Os resultados apontaram que o município de Bauru (SP) apresent uma área de telhado da ordem de 139,91 = 3,12m2 para residências, de 5,58 m2.hab-1 para apartamentos e uma área média ponderada de 132,18 m2 por domicílio. Apresentando uma área média per capita de 49,21 m2. Verificou-se que em todas as faixas de consumo per capita, para o volume de reservatório de 0,5 m3.hab-1, o lançamento de água pluvial na rede coletora de esgoto apresentou eficiência com valores menores que 30% para as áreas específicas de cobertura de 4 a 17 m2.hab-1, portanto... / Several studies have been conducted proposing water conservation techniques to minimize the treated water consumption. Among them stands out the rainwater utilization in activities that may dispense the potability. In Brazil, the pricing on the collection and treatment services of sewage, is generally performed based on the volume of treated water measured at the meter of the consumer unit. Therefore, this sewage disposal generated by rainwater utilization system is not accounted for sewage charging system on the cost of disposal and treatment. The use of this rainwater underestimates the volume of sewage generated. This paper proposes the application of the methodology for setting this return coefficient to estimate the volume of rainwater released in the sewage disposal system linked to the volume of treated water measured at the meter of each consumer unit. The sanitary bowl with box attached was adopted as an object of study. From the collection of roof areas sampling the city of Bauru (SP) determined the average area of the roof. Different simulations of determining roof areas, reservoir volumes and water consumption demands were made, in order to analyze the return coefficient setting behavior for the average area of roof per capita (m2.hab-1). The results showed that the city of Bauru (SP) features a roof area of approximately 139.91 = 3.12 m2 for homes, 5.58 m2.hab-1 for apartments and wa weighted average area of 132.18 m2 per household. With an average are per capita of 49,21 m2. It was found that in all per capita consumpetion ranges, for volume of 0.5 m3 reservoir/in habitant, the release of rainwater in the sewage disposal system was efficient with values less than 30% specific coverage areas 4-17 m2.hab-1 therefore concluded that discharges into sanitary bowl were not met fully by rainwater utilization system. In this way it was stated that not all use of water for unloading in sanitary bowl is transferred to the collection...
10

Eficiência de um sistema de desinfecção solar de águas residuárias domésticas com adição de diferentes doses de peróxido de hidrogênio / Efficiency of a domestic wastewater solar disinfection system with addition of different doses of hydrogen peroxide

Alves, Thaís Regina [UNESP] 24 August 2015 (has links) (PDF)
Made available in DSpace on 2016-03-07T19:21:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-24. Added 1 bitstream(s) on 2016-03-07T19:25:07Z : No. of bitstreams: 1 000858286.pdf: 1499039 bytes, checksum: 460d689a66461ea0c561d04801e8de3b (MD5) / O presente trabalho teve como objetivo avaliar a eficiência de um sistema de desinfecção solar com adição de diferentes doses de peróxido de hidrogênio (H2O2) na desinfecção de águas residuárias domésticas para fins de reúso na agricultura irrigada, usando como parâmetro de qualidade as recomendações da Organização Mundial da Saúde (WHO). Além disso, foi analisada a ocorrência de reativação bacteriana 24 e 48 horas após o fim do processo de desinfecção solar. Foram testadas cinco doses de H2O2 (25, 50, 75, 100 e 125 mg L-1) além do grupo controle (0 mg L-1), com seis repetições de cada, em duas lâminas de efluente (10 e 20 cm). Em quatro repetições, as coletas foram feitas em intervalos de cinco horas (8:00, 13:00 e 18:00 h). Nas duas repetições restantes, as coletas foram feitas em intervalos de duas horas (8:00, 10:00, 12:00, 14:00, 16:00 e 18:00 h). Foi desenvolvido um modelo matemático para cada dose avaliada e um modelo geral para todas as doses de H2O2. Os resultados mostram um aumento considerável da eficiência da desinfecção solar com adição de doses de H2O2 maiores de 25 mg L-1, com consequente redução no período de exposição necessário para a obtenção de efluente com qualidade para reúso irrestrito na agricultura irrigada. Na maior dose avaliada e nos meses mais quentes do ano, o período de desinfecção chega a ser inferior a um dia, dependendo das demais condições ambientais e do afluente. No grupo controle, esse período chega a ser maior do que três dias. A reativação bacteriana ocorreu em todos os grupos avaliados, exceto para ... / The aim of this study was to evaluate the efficiency of a solar disinfection system with addition of different doses of hydrogen peroxide to disinfect domestic wastewater for reuse purposes in irrigated agriculture, using as quality parameter the World Health Organization (WHO) recommendations. Furthermore, the occurrence of bacterial reactivation was analyzed 24 and 48 hours after the disinfection process. Five doses of hydrogen peroxide (25, 50, 75, 100 and 125 mg L-1) were tested plus the control group (0 mg L-1), with six replicates of each in two effluent depths (10 and 20 cm). In four replicates, the samples were taken at intervals of five hours (8:00, 13:00 and 18:00 h). The remaining two replicates, samples were taken at intervals of two hours (8:00, 10:00, 12:00, 14:00, 16:00 and 18:00 h). A mathematical model for each dose evaluated and a general model for all doses were developed. The results showed a considerable increase in the efficiency of solar disinfection with the addition of hydrogen peroxide greater than 25 mg L-1, with consequent reduction in the exposure time required to obtaining effluent with quality for unrestricted use in irrigated agriculture. For the highest dose evaluated and in the warmer months of the year, the disinfection period remained below one day, depending on environmental conditions and the affluent's characteristic. In the control group, the period was longer than three days. Bacterial reactivation occurred in all groups except for the 125 mg L-1 dose and 10 cm wastewater depth. It may be concluded than, that the use of controlled doses of hydrogen peroxide is capable of considerably increase the efficiency of the disinfection process, especially in the higher dose evaluated. In addition, the effluent of such treatment can be allocated to irrigated agriculture for products that can be eaten uncooked, according to WHO (2006).

Page generated in 0.0586 seconds