• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2170
  • 190
  • 143
  • 29
  • 24
  • 24
  • 23
  • 23
  • 15
  • 15
  • 10
  • 10
  • 10
  • 10
  • 10
  • Tagged with
  • 2628
  • 1112
  • 589
  • 460
  • 433
  • 271
  • 261
  • 261
  • 216
  • 211
  • 204
  • 181
  • 180
  • 172
  • 166
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1291

Desenvolvimento de célula Pockels na topologia reflexiva aplicada a TP óptico de alta tensão. / Pockels cell development in topology reflective applied high voltage optical TP.

Rubini Junior, Jonas 26 January 2016 (has links)
O trabalho aborda o estudo e o desenvolvimento de um interferômetro sensor de alta tensão, baseado em célula Pockels (modulador eletro-óptico) na topologia reflexiva (\"double pass\") e que é parte integrante de um Transformador de Potencial Óptico (TPO), que utiliza sistema interferométrico de luz branca (WLI-White Light Interferometry), que está sendo desenvolvido pelo grupo do Laboratório de Sensores Ópticos (LSO) do PEA-EPUSP, e é capaz de medir diretamente tensões presentes em sistema elétrico de potência (SEP) classe 69kVRMS. Para desenvolver o tema proposto foi feita uma revisão da literatura baseada em livros, artigos e teses para identificar topologias em moduladores eletro-ópticos transmissiva (\"single pass\") e reflexiva (\"double pass\") para definir o tipo de modulador mais adequado para a aplicação em questão. A partir dos estudos e implementações realizadas, verificou-se um enorme potencial para o desenvolvimento e aplicação da topologia \"double pass\" no sensor interferométrico da célula de alta tensão do TPO. A topologia mostrou-se vantajosa em relação aos protótipos dos TPOs desenvolvidos anteriormente, a partir de características tais como: a facilidade de recurso de alinhamento do feixe de luz, construção e reprodução relacionados ao cristal eletro-óptico, diminuição do número de componentes ópticos volumétricos e aumento da rigidez dielétrica da célula sensora. Simulações computacionais foram realizadas mediante a aplicação do método dos elementos finitos (MEF) que contribuíram para o auxílio do projeto da célula sensora, particularmente, para estimativa do valor da voltagem de meia onda, V?, parâmetro importante para o projeto do TPO. Um protótipo do TPO com célula sensora de alta tensão reflexiva foi implementado e testado no laboratório de alta tensão do IEEUSP a partir de ensaios com tensões nominais de 69kVrms a 60Hz e máxima de 140kVrms a 60 Hz. Como resultado deste trabalho, amplia-se o conhecimento e domínio das técnicas de construção de interferômetros sensores de alta tensão na topologia reflexiva aplicadas a TPOs. / This work describes the study and development of a high-voltage interferometer sensor based on Pockels cell (electro-optical modulator) in the reflective topology (double pass), which is part of an optical potential transformer (OPT) using a white light interferometry system (WLI) being developed by the Optical Sensors Laboratory (LSO) group from PEA-EPUSP, which is able to directly measure power electrical system (PES) voltages for the 69kVrms class. To develop the work, a bibliographic review was made on books, papers and theses in order to identify electro-optical modulators related to transmissive (single pass) and reflective (double pass) topologies aiming at defining the most appropriate modulator type for the present application. From the studies and implementations performed, it was realized that there is a huge potential for the development and application of \'double pass\' topology in the OPT high-voltage interferometric sensor. This topology showed to be advantageous compared to previously developed OPT prototypes for characteristics such as: ease of beam alignment feature, construction and reproduction related to the electro optical crystals, decrease of volumetric optical components number and increase of the sensor cell dielectric strength. Computer simulations were performed by applying the Finite Element Method (FEM) that contributed to the sensor cell design, particularly in estimating the half-wave voltage value, V?. The OPT with the reflective high-voltage sensing cell was implemented and tested at the high voltage laboratory of IEE-USP for the 69kVrms at 60Hz nominal voltage and the 140kVrms at 60Hz maximum voltage. As a result of this work, nationwide expertise over the techniques of construction of high-voltage interferometer sensors in reflective topology applied to OPTs was achieved and knowledge was broadened.
1292

Avaliação do perfil in vitro de dissolução de comprimidos de mesilato de imatinibe empregando a cromatografia líquida de alta eficiência / Evaluation of the in vitro dissolution profile of imatinib mesylate tablets using the high performance liquid chromatography

Hanna, Thiago Branco 25 October 2010 (has links)
A leucemia mielóide crônica (LMC) é uma doença cujo marcador molecular é o rearranjo gênico BCR/ABL, original da translocação t(9;22), conhecida como cromossomo Philadelphia. Recentemente, os inibidores da enzima tirosina-quinase têm sido estudados e utilizados para o tratamento da LMC. Nesta classe, está o Mesilato de Imatinibe, uma pequena molécula que inibe competitivamente a BCR/ABL tirosina quinase, impedindo sua atividade. Por não possuir monografia publicada em compêndios oficiais, o objetivo deste trabalho foi avaliar o perfil in vitro de dissolução de comprimidos de mesilato em diferentes condições. A quantificação do fármaco foi feita utilizando a cromatografia líquida de alta eficiência em fase reversa (CLAE-FR) e as análises foram realizadas em uma coluna C18 Gemini Phenomenex®, utilizando como fase móvel tampão acetato de sódio 10,7 mmol/L, pH 3,0:metanol (40:60 v/v). O método foi validado e apresentou-se linear no intervalo de concentração de 10-150 µg/mL (r=0,9993). Os coeficientes de variação obtidos foram inferiores a 2,0 % e a exatidão próxima de 100 %. Também foram avaliados os parâmetros seletividade, robustez, estabilidade e limite de quantificação (10 µg/mL). A avaliação do perfil in vitro de dissolução foi realizada em três diferentes meios de dissolução (HCl 0,1 N, tampão acetato de sódio pH 4,5 e tampão fosfato de potássio monobásico pH 6,8), três velocidades de agitação (50, 75 e 100 rpm) e dois tipos de aparatos (pá e cesta). Os resultados obtidos neste teste indicaram que a forma farmacêutica em estudo é de liberação imediata, uma vez que foi verificada liberação de grande quantidade do fármaco em um curto período de tempo. A comparação dos perfis de dissolução, realizada através do cálculo da eficiência de dissolução, apresentou diferenças em relação à porcentagem do fármaco liberado. a condição mais adequada para avaliar o perfil in vitro de dissolução é o meio de dissolução HCl 0,1 N, aparato da pá e velocidade de agitação de 75 ou 100 rpm. / Chronic myeloid leukemia (CML) is a disease whose molecular marker is the BCR/ABL, original of the translocation t (9; 22), known as the Philadelphia chromosome. Recently, inhibitors of the enzyme tyrosine kinase have been studied and used for the treatment of CML. In this class, is the Imatinib mesylate, a small molecule that competitively inhibits BCR/ABL tyrosine kinase, preventing its activity. To do not have a monograph published in official compendia, the objective of this study was to evaluate the in vitro dissolution of tablets mesylate in different conditions. The quantification of the drug was made using high performance liquid chromatography on reversed phase (RP-HPLC) and analysis was performed on a Phenomenex® Gemini C18 column using a mobile phase of sodium acetate buffer 10.7 mmol/L pH 3.0:methanol (40:60 v/v). The method was validated and presented in a linear concentration range of 10-150 µg/mL (r=0.9993). The coefficients of variation obtained were below 2.0% and accuracy near 100%. We also evaluated the parameters selectivity, robustness, stability and limit of quantification (10 µg/mL). The evaluation of in vitro dissolution was conducted in three different dissolution media (0.1 N HCl, sodium acetate buffer pH 4.5 and potassium phosphate monobasic buffer pH 6.8), three agitation speeds (50, 75 and 100 rpm) and two types of devices (paddle and basket). The results of this tests indicated that the pharmaceutical form in question is immediate release, since it was observed release of large amounts of the drug in a short period of time. The comparison of dissolution profiles, conducted by calculating the dissolution efficiency, showed differences compared to the percentage of drug released. The best conditions to evaluate the in vitro profile of dissolution is the dissolution medium 0.1 N HCl, paddle apparatus and stirring speed of 75 or 100 rpm.
1293

Espectroscopia de lente térmica de alta sensibilidade / High sensitivity Thermal Lens spectroscopy

Cruz, Renato Antonio 27 August 2008 (has links)
A eficácia de métodos convencionais de transmissão, utilizados para medir absorção de materiais altamente transparentes, é geralmente limitada pela reflexão e espalhamento de luz. A espectroscopia de Lente Térmica, por outro lado, não é sensível a esses fenômenos, e tem sido amplamente usada na determinação de baixas absorções ópticas. Neste trabalho, estudamos uma configuração de Lente Térmica de duplo feixe (onda contínua cw), desenvolvida recentemente, e suas aplicações. Essa configuração otimiza a técnica de Lente Térmica, e aumenta significativamente a sensibilidade de medida. Foram realizados alguns cálculos computacionais e testes experimentais dessa configuração, e os resultados foram comparados com os de outra configuração, tradicionalmente utilizada, denominada de feixe duplo no modo-descasado. Várias aplicações foram feitas para líquidos e sólidos. Como resultado, obtivemos o espectro de absorção da água pura entre 350 e 528 nm, que indicou um valor mínimo de aproximadamente 1,5 &#8226 10-5 cm-1 em torno de 380 nm, que é mais baixo do que todos os valores da literatura. Coeficientes tão baixos quanto 2 &#8226 10-7 cm-1 podem ser medidos para a água, com 1W de potência, utilizando essa configuração otimizada. Estimamos um limite de detecção de ~ 6 &#8226 10-9 cm-1 (P = 1 W) para o solvente CCl4, que corresponde (até onde sabemos) ao menor valor já encontrado na literatura para líquidos, utilizando-se laser cw. Quanto à detecção de traços de impurezas, o limite para o Cr (III) em solução aquosa foi de ~ 40 ppb (ng/mL) em 514 nm, que corresponde a aproximadamente metade da concentração máxima ideal de Cr (III) em águas potáveis e naturais. Foram obtidos alguns resultados preliminares para a variação do caminho óptico com a temperatura (ds/dT), em sólidos com diferentes geometrias. Para a sílica fundida (quartzo vítreo) Suprasil, determinamos um limite superior para o coeficiente de absorção, cujos valores, 1 &#8226 10-6 cm-1 (em 493 nm) e 1 &#8226 10-5 cm-1 (em 355 nm), também são menores do que os resultados da literatura nessa região do espectro. A alta sensibilidade da técnica permitiu obter a absorção, em 1064 nm, das matrizes de materiais laser dopados com Nd3+, sendo (1,8 &#177 0,1) &#8226 10-3 cm-1 para o vidro Q-98 (Kigre), e (5 &#177 1 &#8226 10-4 cm-1 para o cristal Nd:YAG. Realizamos também medidas de eficiência quântica de fluorescência em nanocristais semicondutores (CdSe/ZnS) suspensos em THF e tolueno, com resultado aproximadamente 5 vezes mais preciso do que o obtido por técnica convencional de fluorescência. As principais vantagens da configuração otimizada, em relação à tradicional, são: um procedimento experimental simples, boa precisão nas medidas de difusividade térmica e, principalmente, a alta sensibilidade da técnica. As desvantagens são: um tempo de medida mais longo, e a necessidade de amostras maiores. / The efficiency of conventional transmission methods used to measure absorption of hightransparent materials is usually limited by light scattering and reflection. On the other hand, Thermal Lens spectroscopy is insensible to such phenomena and has been widely applied to determinate low optical absorptions. In this thesis, we have studied a recently developed dualbeam (continuous wave - cw) Thermal Lens configuration as well as its practical applications. This configuration optimizes the technique and significantly improves the measurement sensitivity. Some computational calculations and experimental tests of this approach were carried out. The results were compared with those obtained using a traditional configuration, named Mode-mismatched Dual-beam Thermal Lens. Several applications were made for liquids and solids. As a result, we obtained the absorption spectrum for pure water in the range of 350 to 528 nm, which indicated a minimal value of approximately 1,5 &#8226 10-5 cm-1 around 380 nm, that is lower than those found in literature. Absorption coefficients as small as 2 &#8226 10-7 cm-1, can be measured for water, using 1W of excitation power, with this optimized configuration. We have estimated a detection limit of ~ 6 &#8226 10-9 cm-1 (P = 1 W) for CCl4 solvent, which corresponds (to the best of our knowledge) to the smallest value found in the literature for liquids using cw laser. With regard to the chemical trace analysis, the detection limit was ~ 40 ppb (ng/mL) at 514 nm for Cr (III) in aqueous solutions, which is nearly half of the maximum desired Cr (III) concentration in drinking and natural waters. Some preliminary results for the temperature coefficient of the optical path length (ds/dT) were obtained at solids with different geometries. For the fused-silica (vitreous quartz) Suprasil, we have determined an upper limit for the absorption coefficient, whose values, 1 &#8226 10-6 cm-1 at 493 nm, and 1 &#8226 10-5 cm-1 at 355 nm, also are lower than the values found in literature in this spectrum region. The high sensitivity of the technique allowed us to measure the absorption (at 1064 nm) of matrices of Nd3+ doped laser materials: (1,8 &#177 0,1) &#8226 10-3 cm-1 for Q-98 glass (Kigre), and (5 &#177 1) &#8226 10-4 cm-1 for Nd:YAG crystal. We carried out as well measurements of fluorescence quantum yield of semiconductor nanocrystals (CdSe/ZnS) suspended in THF and toluene solvents, whose result was approximately 5 times more accurate than that obtained with the conventional fluorescence technique. The main advantages of the optimized configuration are: a simple experimental procedure, a good accuracy for thermal diffusivity measurements, and most important the high sensitivity of the technique. The drawbacks are: a longer time of measurements, and the requirement of larger samples.
1294

Capacitação das operações internas para a customização em massa: estudos de casos nas indústrias brasileiras. / Enablers in internal operations to mass customization: case of brazilians industries.

Vigna, Cláudio Marcos 17 May 2007 (has links)
A Customização em Massa é uma estratégia de negócios relativamente recente que foi idealizada em meados dos anos oitenta, emergiu no meio empresarial em meados dos anos noventa, e, desde então tem sido adotada por muitas empresas devido ao diferencial competitivo que propicia. O objetivo desta estratégia é atender os desejos individuais dos clientes em grande escala e com maior lucratividade para a empresa. A adoção bem sucedida da Customização em Massa exige profundas alterações em áreas críticas das empresas. O objetivo do presente trabalho é, num primeiro momento, avaliar quais são essas áreas críticas que necessitam mudanças, e num segundo momento, quais são os elementos capacitadores necessários. O trabalho apresenta um modelo conceitual de definições sobre capacitação organizacional, competência funcional, técnicas operacionais e recursos organizacionais. Posteriormente verificou-se a influência destes elementos nos processos e como se dá a aplicação dos mesmos em diferentes setores industriais. A realização deste estudo baseou-se em cleta de dados por meio de questionários e na aplicação do método de estudo de caso em empresas de dois setores industriais, o automobilístico e o de alta tecnologia. A escolha destes setores justifica-se pelo fato deles se encontrarem, historicamente, na vanguarda da adoção das melhores práticas empresariais. Como resultado constatou-se que determinados elementos capacitam a empresa para a Customização em Massa em um setor mas não para outro, ou seja, não existe uma solução genérica para a capacitação organizacional em Customização em Massa. Observou-se também que a simples adoção dos elementos capacitadores não gera a competência funcional requerida em determinada área crítica para a geração desta capacitação organizacional; é também necessário que haja sinergia na aplicação destes elementos. / The customization is a recent strategy that appeared in the middle of 80\'s and currently it emerged in the enterprise environment. Such strategy has been adopted for many companies due to the competitive differential that it supplies. The objective of this strategy is to fulfill the most specific customers\' desires in large-scale and with increasing profitability to the company. The successful adoption of Mass Customization demand deep changes in many critical areas of the enterprise. The purpose of this paper is to analyses which are the critical areas that need to be changed, and which are the Mass Customization enablers. This research presents a conceptual definitions for resources, operational techniques, competences, and organizational capabilities required for Mass Customization. The paper presents a literature review on the issue of planning and deploying Mass Customization initiatives pointing out important resources and techniques that have been adopted by the adherents of this new strategy. It was perceived the influence of these enablers in its respective processes and its different applications in different industrial sectors. To this was adopted the method of case survey in two differents sectors, the automobile and high technology. This choice was proposital because this sector are in the vanguard of the best practices adoption. To have a valid classification of the enablers was elaborated two models. As a result was perceived that some enablers could be applied to one sector and not applied in others to reach the Mass Customization capacity. It does not exist a generic solution for a Mass Customization strategy adoption, because different sectors demands different enablers. It was also observed that the simple adoption of this enablers does not generate the enterprise competence demanded, being necessary the existence of a synergy between and focus of these enablers.
1295

Avaliação de métodos de análises não lineares em sinais eletroencefalográficos na presença de oscilações de alta frequência em pacientes portadores de epilepsia refratária / Evaluation of nonlinear analysis methods in electroencephalographic signals in the presence of high frequency oscillations in patients with refractory epilepsy

Duque, Juliano Jinzenji 09 August 2017 (has links)
A eletroencefalografia (EEG) é uma das evidências tomadas na avaliação de indicação cirúrgica, em casos de pacientes portadores de epilepsia refratária a medicamentos, que pode auxiliar na localização da área responsável pela origem das crises epilépticas. Ao longo das últimas décadas, além das bandas de frequências já tradicionalmente avaliadas (até cerca de 40Hz), a EEG tem despertado o interesse de pesquisadores também para bandas de frequências mais altas. Passaram a ser encontradas evidências de que oscilações de alta frequência, conhecidas por HFO (High Frequency Oscillations), podem ser usadas como biomarcadores de epilepsia. Diversos estudos têm sido realizados em busca de uma melhor compreensão sobre HFO, a fim de viabilizar sua utilização em aplicações clínicas. Entretanto, características não lineares e de complexidade, que podem contribuir na análise de sinais com origem em sistemas biológicos, não têm sido investigadas neste tipo de sinais. Este estudo propôs a investigação de características extraídas de sinais de EEG com presença de HFO, de pacientes portadores de epilepsia refratária, através de métodos considerados como de análise não linear. Análise de Dinâmica Simbólica, Análise de Flutuações Destendenciadas (DFA), Entropia Multiescala (MSE) e Análise qSDiff foram aplicadas em segmentos de sinais de EEG intracraniano, amostrados a 5kHz, de pacientes portadores de epilepsia refratária, e também em alguns sinais simulados de características conhecidas para fins de comparação. Os resultados dos diferentes métodos investigados apontaram características semelhantes entre os segmentos de EEG analisados e séries simuladas de ruído browniano, sugerindo que os sinais de EEG em geral têm perfil bastante suavizado, são não estacionários e exibem correlações de longo alcance. Foram também levantadas evidências de que tanto HFO quanto os segmentos de EEG onde estão inseridas têm padrões mais regulares de variação e são menos complexas que segmentos de EEG sem HFO, sugerindo a degradação da complexidade fisiológica desta região cerebral, que poderia estar relacionada com mecanismos fisiopatológicos da epilepsia. Todos os métodos investigados sugeriram que as características e propriedades não lineares, relacionadas a complexidade inerente dos sinais de EEG, podem ser úteis na análise de HFO, principalmente pelas evidências de que estas características se alteram nas HFO, quando comparadas ao restante do sinal onde elas se encontram e também a outros sinais sem sua presença. / Electroencephalography (EEG) is one of the evidences taken in the evaluation of surgical indication, in cases of patients with drug refractory epilepsy, which may help in locating the area responsible for the origin of epileptic seizures. Over the last few decades, in addition to the frequency bands that have traditionally been evaluated (up to about 40Hz), the EEG has attracted researchers also to higher frequency bands. Evidence has been found that high frequency oscillations (HFO), can be used as biomarkers of epilepsy. Many studies have been carried out in search of a better understanding about HFO, in order to make it feasible to use in clinical applications. However, nonlinear and complex features, which may contribute to the analysis of signals originating from biological systems, have not been investigated in this type of signals. This study proposed the investigation of features extracted from EEG signals with HFO of patients with refractory epilepsy, using nonlinear analysis methods. Symbolic Dynamics Analysis, Detrended Fluctuation Analysis (DFA), Multiscale Entropy (MSE) and qSDiff Analysis were applied to segments of intracranial EEG signals, sampled at 5kHz, from patients with refractory epilepsy, as well as some features-known simulated signals for comparison purposes. Results of the different investigated methods pointed out similar features between the analyzed EEG segments and the simulated series of Brownian noise, suggesting that EEG signals, in general, have a very smoothed profile, are nonstationary and exhibit long- range correlations. Evidence has also been raised that both HFO and the EEG segments where they are inserted have more regular patterns of variation and are less complex than EEG segments without HFO, suggesting the degradation of the physiological complexity of this brain region, which could be related to pathophysiological mechanisms of epilepsy. All the investigated methods suggested that nonlinear features and properties, related to the inherent complexity of EEG signals, may be useful in HFO analysis, mainly because of the evidence that these features change in HFOs when compared to the rest of the signal where they are and other signals without their presence.
1296

Braços espirais da galáxia: posição das regiões HII gigantes e formação estelar / Spiral Arms of the Galaxy: Position of the giant HII Regions and Star Formation

Moisés, Alessandro Pereira 08 April 2010 (has links)
Nesta tese é apresentado um catálogo fotométrico no infravermelho próximo de 35 Regiões HII, todas pertencentes ao disco Galáctico. Esta faixa espectral é útil uma vez que os comprimentos de onda são grandes o suficiente para se ter uma baixa extinção interestelar comparada ao visível, e são pequenos o suficiente para diagnosticar as fotosferas estelares. Foram obtidas imagens nas bandas J, H e K e imagens do Spitzer nos canais de 3,5, 5,8 e 8,0 m. Após a fotometria nas imagens JHK, foi possível construir diagramas cor-cor e cor-magnitude. Foram utilizadas imagens coloridas, compostas de uma combinação RGB das imagens nas três bandas, tanto para as imagens JHK quanto para as imagens do Spitzer. Estas imagens, junto com os diagramas, foram utilizadas para levantar candidatos a fontes ionizantes das regiões HII, assim como objetos ainda em estágios primordiais de evolução (CTTs e MYSOs). Estes dados também foram utilizados para associar à cada região HII um estágio evolutivo (de A até D, da região mais jovem à mais evoluída). Baseado na posição da Sequência Principal em diagramas cor-magnitude, foi possível comparar as distâncias cinemáticas com nossos dados. Além disso, quando possível, foram utilizadas distâncias de regiões HII determinadas por paralaxe espectrofotométrica (disponíveis na literatura) e utilizando duas leis de extinção interestelar extremas mostrou-se que estas distâncias são menores que suas contrapartidas cinemáticas, e estão em acordo com distâncias determinadas por outros métodos, como por paralaxe trigonométrica. Sabendo que estas regiões de formação estelar seguem a dinâmica do gás, o mapeamento da distribuição destas regiões permite checar a estrutura espiral da Via Láctea. / In this work, a near infrared photometric catalog of 35 HII regions that belongs to the Galactic plane is presented. This spectral range is useful since the wavelengths are long enough to have less influence of the interstellar extinction compared to the visible domain, and they are small enough to still show stellar photospheric features. Images of these HII regions in the J, H and K-band together with IRAC-Spitzer images (channels 4.5, 5.8 and 8.0 m) were used. After the photometry in the JHK images, color-color and color-magnitude diagrams were constructed. These two group of images (JHK and 4.5, 5.8 and 8.0 m) colored in a RGB combination were used, together with the diagrams, to identify the ionizing sources candidates, as well as objects still embedded in their natal cocoon (CTTs and MYSOs). An evolutionary stage to these regions (from A to D, from the younger region to the more evolved) was inferred based on the images and diagrams. These diagrams were also used to infer if the kinematic distance is correct, based on the Main Sequence location. Non-kinematic distances to several HII regions, when it was possible, were collected from the literature. Using two extreme interstellar extinction laws, it was possible to compare these distances with the kinematic results. These non-kinematic distances are lower than that from kinematic techniques. Also, these distance discrepancies are in agreement with distances derived by others methodologies, as trigonometric parallax. Since these star forming regions follow the gas dynamics, mapping their distribution along the Galaxy allows to check the spiral pattern of the Milky Way.
1297

Desenvolvimento da técnica de precessão livre no estado estacionário para aumento da razão sinal ruído em espectros de RMN de alta resolução / Use of steady state free precession (SSFP) to enhance signal to noise ratio in high resolution NMR

Santos, Poliana Macedo dos 16 March 2009 (has links)
Neste trabalho realizou-se uma analise detalhada das vantagens e desvantagens da sequencia de Precessao Livre no Estado Estacionario (Steady State Free Precession - SSFP) para aquisicao rapida de espectros de Ressonancia Magnetica Nuclear (RMN) de 13C. O regime de SSFP e obtido atraves da aplicacao de um trem de pulsos de mesma fase, duracao e intensidade, separados por um intervalo de tempo (Tp) menor que os tempos de relaxacao longitudinal (T1) e transversal (T2) da amostra. Nestas condicoes e possivel acumular dezenas de espectros por unidade de T1, proporcionando um incremento significativo na razao sinal/ruido (s/r) do espectro. Ao comparar os resultados obtidos com as sequencias de SSFP e convencional (pulsos de 90 graus e T 5T1 p >= ), verificou-se que a SSFP apresentou um ganho medio de 30 vezes no tempo de analise para uma mesma s/r. No entanto, os espectros obtidos com a SSFP apresentam anomalias de fase e amplitude do sinal, decorrente da refocalizacao da magnetizacao na forma de um eco de spin. Comparou-se tambem a SSFP com a sequencia padrao usada para obtencao de espectros de 13C, que utiliza pulsos de 30 graus e Tp = 1.38s. Neste caso os ganhos da SSFP foram menores (5,5 vezes no tempo de analise para uma mesma s/r) verificando que a sequencia padrao utiliza a vantagem da SSFP (Tp < T1, T2). A formacao do eco e, consequente das anomalias de fase nao sao observadas na sequencia padrao, pois a aquisicao do sinal e truncada em 0,9s, e a ciclagem de fase dos pulsos reduz a formacao do eco, por levar a uma perda de coerencia do sinal SSFP. Neste trabalho tambem analisou-se os metodos propostos por Rudakov, Freeman e Hill e Schwenk para supressao destas anomalias nos espectros de RMN 13C quando adquiridos no regime de SSFP. Os resultados demonstraram que a aplicacao destas metodologias proporciona uma melhora significativa na qualidade do espectro. No entanto, verificou-se que nenhum metodo foi capaz de suprimir totalmente as anomalias de fase e amplitude do sinal. / It was performed a detailed analysis of the advantages and disadvantages of Steady State Free Precession (SSFP) sequence for a rapid acquisition of 13C Nuclear Magnetic Resonance (NMR) spectra. The SSFP regime is obtained by the application of a pulse train with the same phase, duration and intensity, separated by a time interval (Tp) shorter than the transverse (T2) and longitudinal (T1) relaxation times. In these conditions it is possible to accumulate tens of spectra per units of T1, providing a significant increase in the spectrum signal-to-noise ratio (s/n). By comparing the spectra obtained by SSFP and conventional pulse sequence (90 degree pulse and T 5T1 p >= ) it was noted that SSFP shows an average gain of 30 times in analysis time for the same s/n. However, the SSFP spectra show phase and intensity anomalies due to the refocusing of the magnetization, generating a spin echo. We also compared the SSFP with the standard 13C pulse sequence, that uses a 30 degree pulses and Tp = 1.38 s. In this comparison the SSFP gain were small (5,5 times in analysis time for the same s/n), because the standard sequence also uses the advantage of SSFP (Tp < T1, T2). The echo signal and the phase anomalies are not observed in the standard sequence because the signal acquisition is truncated at 0.9s and the cycling of the pulse phase, that partially destroy the SSFP coherence. We also analyzed the methods proposed by Rudakov, Freeman and Hill and Schwenk to suppress those anomalies in the 13C NMR spectrum when acquired in SSFP regime. The results showed that the application of these methodologies provides a significant improvement in the spectrum quality. However, it was verified that none of the methods were able to completely eliminate the phase and intensity anomalies.
1298

Relação entre concentração sanguínea de cocaí­na e cocaetileno com a gravidade das manifestações clí­nicas apresentadas por pacientes com diagnóstico de intoxicação por cocaína / Relationship between blood concentration of cocaine and cocaethylene with the severity of clinical manifestations presented by patients diagnosed with cocaine intoxication

Zucoloto, Alexandre Dias 15 May 2018 (has links)
As intoxicações decorrentes do uso de drogas de abuso representam atualmente um grave problema para a saúde pública. Dentre os principais agentes envolvidos, destaca-se a cocaína. Ela se tornou uma das drogas mais consumidas ao redor do mundo, sendo um dos principais motivos de atendimentos em pronto-socorro (PS) devido ao uso de substâncias ilícitas. Seu uso ocorre principalmente em associação com bebida alcóolica. Existem poucos estudos realizados que relacionem a concentração sanguínea de cocaína e a gravidade das manifestações clínicas em populações que a utilizam como droga de abuso, e que envolvam pacientes atendidos em PS. O objetivo do presente estudo foi verificar a possível relação entre concentração sanguínea de cocaína e cocaetileno (produto da interação de cocaína com etanol) com a gravidade das manifestações clínicas apresentadas por pacientes com hipótese diagnóstica de intoxicação por cocaína. As concentrações sanguíneas foram determinadas por cromatografia líquida de alta eficiência (HPLC) e a gravidade das manifestações clínicas foi avaliada através do Stimulant Intoxication Score (SIS). Dos 81 pacientes incluídos no estudo 77,8% são homens com idade média de 32,5 anos ± 8,5 e SIS médio de 3,4 ± 2,5. Do total de pacientes incluídos no estudo 20 (24,7%) tiveram resultados positivos em sangue para os analitos de interesse, sendo a concentração sanguínea média de cocaína igual a 0,34 &#181;g/mL ± 0,45 e de cocaetileno igual a 0,38 &#181;g/mL ± 0,34. A concentração sanguínea de cocaína e cocaetileno não se mostrou informação útil para tratamento e prognóstico dos pacientes, porém a detecção no sangue destas substâncias no momento do atendimento, independentemente de sua concentração, pode ser um indicador de gravidade, mostrando que quaisquer concentrações destas substâncias devem ser consideradas potencialmente tóxicas. A aplicação do score SIS revelou-se como importante alternativa capaz de predizer a gravidade dos pacientes atendidos devido a intoxicação por cocaína de maneira rápida e simplificada. / Currently, poisoning resulting from the abuse of drug represents a serious problem for public health. Among the main agents involved, cocaine stands out. It became one of the most abused drugs around the world, being one of the main reasons for visits to the emergency room due to the use of illicit substances. The use of cocaine is primarily in combination with alcoholic beverages. There are few studies that relate cocaine blood concentration and the severity of its clinical manifestations in patients attended in the Emergency Room. The aim of the present study was to verify the possible relationship between the blood concentration of cocaine and cocaethylene (product of the interaction of cocaine with ethanol) with the severity of the clinical manifestations presented by patients with cocaine intoxication. Blood levels were measured by high-performance liquid chromatography (HPLC) and the severity of clinical manifestations was assessed using the Stimulant Intoxication Score (SIS). Of the 81 patients included in the study, 77.8% were men with a mean age of 32.5 years ± 8.5 and mean of SIS 3.4 ± 2.5. From the total of patients included in the study 20 (24.7%) had positive blood results for the analytes of interest, being the mean blood concentration of cocaine equal to 0,34 &#181;g/mL ± 0,45 and of cocaethylene equal to 0,38 &#181;g/mL ± 0,34. The blood concentration of cocaine and cocaethylene has not been shown to be useful information for the treatment and prognosis of patients, but blood levels of these substances at the time of treatment, regardless of their concentration, may be an indicator of severity, showing that any concentrations of these substances should be considered as potentially toxic. The application of the SIS score proved to be an important alternative capable of predicting the severity of the patients attended due to cocaine intoxication in a fast and simplified way.
1299

Alta hospitalar responsável: em busca da continuidade do cuidado para pacientes em cuidados paliativos no domicílio, uma revisão integrativa / Responsible Discharge: in search of continuity of care for patients in Palliative Care at home, an integrative review

Ignacio, Denise Sarreta 28 March 2017 (has links)
O presente projeto de pesquisa tem como foco a atenção domiciliar e mais especificamente, o processo de desospitalização, isto é, o processo de alta hospitalar articulado à rede de atenção à saúde com o objetivo de viabilizar a continuidade do cuidado integral no domicílio, com enfoque em Cuidados Paliativos. Imprescindível para que se garanta o cuidado integral à pessoa, que a comunicação seja efetiva, entre os três atores principais: o paciente dependente de cuidado domiciliar juntamente com a família, no papel do cuidador principal; o Hospital que definiu o diagnóstico e tratamento; e a rede municipal de saúde, que seja através do SAD ou da Unidade Básica de Saúde/Saúde da Família (UBS/USF), se responsabilizará pelo acompanhamento e continuidade desse cuidado no domicílio. O objetivo do estudo é analisar as evidências disponíveis na literatura sobre o processo de alta do paciente em Cuidado Paliativo. Para alcançar o objetivo proposto, realizamos uma Revisão Integrativa (RI). A questão norteadora para a realização desta revisão integrativa foi: \"Quais são as evidências disponíveis na literatura sobre o planejamento da alta hospitalar, como garantia da continuidade do cuidado, a pacientes em cuidados paliativos?\" A busca de artigos foi realizada em julho/2016, nas bases de dados PubMed, LILACS e CINAHL, com os seguintes descritores controlados: home care services, Patiente Discharge, Summaries patient discharge, Continuity of patient care e Patient Care planning, Serviços de Assistência Domiciliar, Alta do paciente e Continuidade da Assistência ao Paciente, além de descritores não controlados (palavras-chave), sendo estes home care services, Patiente Discharge, Continuity of patient care, Serviços de Assistência Domiciliar, Alta do paciente e Continuidade da Assistência ao Paciente. A amostra foi composta de oito estudos primários, onde foi apresentada a importância do Cuidado Paliativo, o desejo dos pacientes terem sua terminalidade em casa e alguns métodos para que se alcance esse objetivo. Na Brasil, a população conta com sistema público de saúde estruturado a partir do direito à saúde como prerrogativa constitucional, mas ainda ocorrem dificuldades de acesso. A falta de integração entre os profissionais e serviços hospitalar e unidades básicas de saúde ou de saúde da família podem produzir resultados negativos. O cuidador é um elemento chave no processo de planejamento de alta hospitalar. A continuidade do cuidado tem grande relação com o preparo a ele ofertado e o acompanhamento e apoio das equipes técnicas responsáveis. À Enfermagem é atribuída a responsabilidade pelo preparo do cuidador. Além disso, a elaboração do plano de cuidados e o início da capacitação do cuidador deve ocorrer ainda durante a hospitalização. A necessidade de capacitação não se limita ao cuidador, mas também aos trabalhadores da atenção básica. A alta hospitalar é uma transição específica e prevê a continuidade dos cuidados em domicílio. Apresentamos uma síntese dos elementos norteadores do planejamento de alta encontramos / The present research project focuses on home care and, more specifically, the process of dehospitalization, that is, the process of hospital discharge articulated to the health care network with the objective of enabling the continuity of integral care at home, with focus In Palliative Care. Essential for guaranteeing comprehensive care to the person, that communication be effective, among the three main actors: the patient dependent on home care together with the family, in the role of the main caregiver; The Hospital that defined the diagnosis and treatment; And the municipal health network, through the SAD or the Basic Health / Family Health Unit (UBS / USF), will be responsible for the follow-up and continuity of this care at home. The objective of the study is to analyze the available evidence in the literature on the patient discharge process in Palliative Care. To achieve the proposed goal, we performed an Integrative Review (IR). The guiding question for the accomplishment of this integrative review was: \"What evidence is available in the literature on planning hospital discharge as a guarantee of continuity of care for patients in palliative care?\" The search for articles was conducted in July / 2016 , In the PubMed, LILACS and CINAHL databases, with the following controlled descriptors: home care services, Patient Discharge, Patient Discharge Summaries, Continuity of patient care and Patient Care planning, Home Care Services, Patient Discharge and Continuity of Care Patient, in addition to uncontrolled descriptors (keywords), being these home care services, Patient Discharge, Continuity of patient care, Home Care Services, Patient discharge and Continuity of Patient Care. The sample consisted of eight primary studies, where the importance of Palliative Care, the patients\' desire to have their terminality at home and some methods to achieve this goal were presented. In Brazil, the population has a public health system based on the right to health as a constitutional prerogative, but access difficulties still exist. The lack of integration between hospital professionals and services and basic health or family health units can produce negative results. The caregiver is a key element in the hospital discharge planning process. The continuity of the care has a great relation with the preparation offered to him and the accompaniment and support of the responsible technical teams. Nursing is assigned responsibility for preparing the caregiver. In addition, the preparation of the plan of care and the beginning of the training of the caregiver should occur even during hospitalization. The need for training is not limited to the caregiver, but also to primary care workers. Discharge is a specific transition and provides for continuity of care at home. We present a synthesis of the guiding elements of the high planning we found
1300

Desenvolvimento, avaliação e aplicação de um sistema de cromatografia gasosa de alta pressão / Development, implementation and evaluation of a system of high pressure gas chromatography

Silva, Meire Ribeiro da 17 August 2012 (has links)
A cromatografia é uma técnica de separação cuja classificação se dá por meio do estado físico da fase móvel (líquido, gasoso, supercrítico, entre outros). Dentre as técnicas cromatográficas mais utilizadas e cujo conhecimento é bastante conhecido está a cromatografia gasosa. Embora esta técnica tenha sido bastante estudada existem ainda algumas vertentes que não totalmente estudadas, sendo uma delas a cromatografia gasosa de alta pressão na entrada da coluna (HIPGC). A HIPGC destaca por oferecer vantagens analíticas como alta eficiência, maior velocidade no tempo de análise e também facilita a migração de compostos com alta massa molecular. As desvantagens e dificuldades estão concentradas na instrumentação. O uso de alta pressão requer conexões que suportem tal pressão, sistema de injeção adequado a fim de eliminar vazamentos entre outros. Neste trabalho, sucessivos sistemas instrumentais foram montados visando o desenvolvimento, aprimoramento e avaliação de um sistema instrumental simples e versátil para HIPGC. Na avaliação do sistema foi utilizada coluna capilar empacotada pelo método \"slurry packed\". A escolha da coluna foi realizada a partir de curvas de eficiência de Van deemter. O sistema instrumental desenvolvido para HIPGC é apropriado para pressões de entrada de até 1800 psi. Além disso, este sistema apresentou boa reprodutibilidade nas análises e não apresentou vazamentos. Os resultados mostraram o potencial da técnica HIPGC na redução do tempo de análise. / Chromatography is a separation technique whose classification takes place by means of the physical state of the mobile phase (liquid, gas, supercritical, etc.). Among the most commonly used chromatographic techniques and whose knowledge is well known is gas chromatography. Although this technique has been widely exploited there are some topics which weren\'t fully investigated, one of them being high-pressure chromatography column input (HIPGC). HIPGC shows analytical advantages as high efficiency, faster analysis time and facilitates the migration of compounds with high molecular mass. The main difficulties in HIPGC are found in the instrumentation. The high pressure requires an appropriate connection that works in this range of pressure and one injection system suitable to transport the sample at different pressures. In this work, different instrumental systems were assembled to develop equipment to HIPGC that is simple and versatile. In the system evaluation was used capillary columns packed by methodology\'s \"slurry packed\" were used. The choice of the column was made from van Deemter efficiency curves. The system developed for instrumental HIPGC it is appropriate for inlet pressures up to 1800 psi. Furthermore, this system showed good reproducibility of analysis and didn\'t show leaks. The results showed the potential of HIPGC, such as shorter analysis time.

Page generated in 0.035 seconds