• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2170
  • 190
  • 143
  • 29
  • 24
  • 24
  • 23
  • 23
  • 15
  • 15
  • 10
  • 10
  • 10
  • 10
  • 10
  • Tagged with
  • 2628
  • 1112
  • 589
  • 460
  • 433
  • 271
  • 261
  • 261
  • 216
  • 211
  • 204
  • 181
  • 180
  • 172
  • 166
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
641

Análise farmacêutica de tibolona em cápsulas magistrais por cromatografia líquida de alta eficiência

ÂNGELO, Marilene Lopes 04 February 2013 (has links)
A tibolona é um fármaco cuja estrutura química derivada da 19-nortestosterona e devido as suas atividades estrogênicas, androgênicas e progestogênicas é utilizada para tratamento de sintomas da menopausa relacionados a deficiência estrogência em mulheres pós-menopausadas e também com indicação na prevenção da osteoporose. Não há monografia oficial para quantificação de tibolona na forma farmacêutica cápsulas nem teste de dissolução. Sendo assim, o objetivo desse estudo foi desenvolver, validar e aplicar um método rápido, seletivo, preciso e indicador de estabilidade por cromatografia líquida de alta eficiência (CLAE) para a determinação de tibolona em cápsulas e um teste de dissolução para quantificação in vitro de sua liberação no meio de dissolução. O método indicador de estabilidade foi desenvolvido baseado no ensaio de degradação forçada, submetendo o fármaco a degradação ácida, alcalina, neutra, oxidativa, térmica e luz UV. A separação foi realizada em uma coluna de fase reversa C18 (250 mm x 4,0 mm; 5 µm), com acetonitrila:água (60:40) como fase móvel, vazão de 1 mL/min e detecção UV em 205 nm. O método foi validado e todos os parâmetros ficaram dentro dos limites aceitáveis, segundo o ICH e ANVISA. O método proposto foi aplicado e apresentou resultados satisfatórios na análise quantitativa de tibolona em cápsulas. Também foi desenvolvido um método de dissolução para cápsulas de tibolona, onde o melhor perfil de dissolução obtido, foi alcançado com 0,5% de lauril sulfato de sódio (LSS) em água como meio de dissolução, aparato pá a 100 rpm e tempo de coleta de 45 minutos, na qual a percentagem de tibolona liberada foi maior 80% (Q = 75). A quantificação foi realizada por CLAE a 205 nm. Todos os parâmetros de validação foram considerados satisfatórios. Portanto, os métodos desenvolvidos são adequados para análise de controle de qualidade, estudos de estabilidade, ensaios de dissolução e perfil de dissolução de cápsulas contendo este fármaco. / Tibolone is a drug with chemical structure derived from 19-nortestosterone and estrogenic, androgenic and progestogenic activities. Due to these characteristics, it has been used to treat menopausal symptoms related to estrogen deficiency in postmenopausal women and it has also been indicated for osteoporosis prevention. There is no official monograph for quantification and dissolution tests of tibolone capsules. Hence, the objective of this study was to develop, validate and apply a quick, selective, precise and stability indicating method by high performance liquid chromatography (HPLC) for determination of tibolone in capsules and an in vitro dissolution test for quantification of their release into the dissolution media. Three different commercial formulations were evaluated. The stability indicating assay was developed based on the drug stress study carried out under conditions like acid, alkaline, neutral, oxidative, thermal and UV light degradation. The separation was performed on a C18 reversed-phase column (250 mm x 4.0 mm; 5 µm particle size) with acetonitrile: water (60:40 v/v) as mobile phase at a flow rate of 1 mL/min with UV detection at 205 nm. The method validation presented acceptable limits for all parameters according to ICH and ANVISA. The proposed method was applied in tibolone capsules and showed satisfactory results in their quantitative analysis. In the tibolone capsules dissolution test the best profile was reached with 0,5 % sodium lauryl sulphate (SLS) in water as the dissolution media, paddle apparatus at 100 rpm and collection time at 45 minutes, where the percentage tibolone released was higher than 80% (Q = 75). The quantification was performed by HPLC at 205 nm. All validation parameters were considered satisfactory. Therefore, the developed methods are appropriate for quality control analysis, stability studies, dissolution tests and dissolution profile of capsules containing this drug. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
642

Emprego de polímeros de impressão molecular de acesso restrito para a extração direta de antidepressivos em plasma humano seguido de análise por HPLC

SILVA, Katrine Kyona Muniz Sirgom da 29 July 2014 (has links)
Este trabalho versa sobre o desenvolvimento de um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina (RAMIP-BSA) para a extração direta de antidepressivos inibidores da receptação de serotonina (ISRS) em plasma humano em sistema cromatográfico multidimensional. A síntese do material foi realizada em três etapas. Primeiramente os sítios seletivos foram formados empregando síntese por precipitação e os seguintes reagentes: fluoxetina, ácido metacrílico, etileno glicol dimetacrilato, 2,2 – azo-isso-butironitrila, e metanol como, molécula modelo (MM), monômero funcional (MF), etileno glicol dimetacrilato como agente de ligação cruzada (ALC), iniciador radicalar (IR) e solvente, respectivamente. A segunda etapa consitiu na formação de uma camada hidrofílica pelo recobrimento químico da superfície do material com os monômeros hidrofílicos hidróxi etil metacrilato e glicidil metacrilato. Na terceira etapa o polímero foi revestido com albumina bovina utilizando glutaraldeído como agente de ligação cruzada, formando assim uma cápsula protéica ao redor das partículas. O RAMIP-BSA obtido foi capaz de excluir cerca de 99% das proteinas por ele percoladas, além de apresentar capacidade máxima adsortiva para fluoxetina de cerca de 69 mg g-1, e comprovada seletividade à fluoxetina frente os outros fármacos ISRS. Uma coluna com o RAMIP-BSA foi empregada como fase extratora em um sistema de cromatografia líquida multidimensional para análise direta de ISRS em plasma humano. Foram construídas curvas de calibração para os fármacos venlafaxina (VEN), citalopram (CIT), fluvoxamina (FLUV), duloxetina (DUL), fluoxetina (FLUO) e sertralina (SER) utilizando um pool de plasma humano (n=6) de indivíduos que não utilizam nenhum dos fármacos. Todas as curvas apresentaram r > 0,99 na faixa linear de 20 a 500 μg L-1. A precisão e exatidão foram avaliadas com base no desvio relativo do padrão e no erro relativo respectivamente. Os limites de detecção e quantificação foram de 10 e 20 μg L-1. A recuperação absoluta foi de 85% à 93%. Todos os resultados estão de acordo com as normas do FDA mostraram-se aceitáveis de acordo com as normas do FDA. / In this work, we developed a new restricted access molecularly imprinted polymer coated with albumin (RAMIP-BSA) for the direct extraction of antidepressants receiving serotonin inhibitors (SSRIs) in human plasma in a multidimensional chromatographic system. The synthesis of the material was performed in three steps. Firstly, the selective binding sites were formed by using fluoxetine, methacrylic acid, ethylene glycol dimethacrylate, 2-2'-azoisobutyronitrile, and methanol as template, functional monomer, cross linking agent, radical initiator and solvent, respectively. In the second step, the polymer was chemically covered with a hydrophilic layer by using the monomers hydroxyethyl methacrylate and glycidyl methacrylate. In the third step, the polymer particles were coated with an albumin capsule by using glutaraldehyde as cross linker. The obtained RAMIP -BSA was able to exclude about 99% of the proteins percolated through it, with a maximum adsorption capacity of 69 mg g-1 for the fluoxetine, and good selectivity for the fluoxetine in comparison with other SSRIs. A RAMIP-BSA column was employed as extraction phase in a multidimensional liquid chromatography system for the analyses of SSRIs in human plasma samples. Validation calibration curves were constructed for venlafaxine (VEN) , citalopram (CIT), fluvoxamine (FLUV) , duloxetine (DUL) , fluoxetine (FLUO) and sertraline (SER) using pooled human plasma (n=) individuals who do not use any of drugs. The analytical curves ranged from 20 to 500 mg L-1, with correlation coefficients larger than 0.99 for all the analytes. The precisions and accuracies (intra and inter-day) were evaluated as relative standard deviation and relative error, respectively. The limits of detection and quantification were 10 and 20 mg L-1 for all the analytes. All the validation parameters are in accordance with the FDA recommendation.
643

Desenvolvimento e validação de metodologia analítica para análise de finasterida cápsulas

SANTOS, Olimpia Maria Martins 14 December 2011 (has links)
A finasterida (FNS) é um fármaco sintético 4-azasteróide (azaandrost-1-eno-17-carboxamida, N- (1,1-dimetil)-3-oxo-, (5 , 17 ), inibidor específico do esteróide tipo II, 5 - redutase, uma enzima intracelular que converte a testosterona ao mais potente andrógeno 5 -diidrotestosterona. É classificada como fármaco da classe II (baixa solubilidade e alta permeabilidade) no Sistema de Classificação Biofarmacêutica (SCB). A FNS é indicada no tratamento e controle de homens com hiperplasia prostática benigna (HPB), prevenção e tratamento de câncer de próstata, alopecia androgênica e em alguns casos de hirsutismo. Apesar de o medicamento manipulado oferecer vantagens em relação à facilidade posológica e preço mais acessível, são inúmeros obstáculos que dificultam o avanço do setor de manipulação. O maior destes obstáculos é a falta de credibilidade do produto manipulado pela suposta ausência de um controle de qualidade rígido das matérias-primas e produtos acabados, ausência de controle do processo de produção e sua reprodutibilidade. Para se atingir um objetivo terapêutico esperado, deve-se constatar que o fármaco esteja na concentração indicada pelo fabricante, que libere o princípio ativo na quantidade e velocidade adequadas ao efeito terapêutico. Não há monografia oficial para quantificação de FNS na forma farmacêutica cápsulas nem teste de dissolução. Com isso, desenvolver uma metodologia analítica para quantificação da FNS em cápsulas manipuladas, que seja rápida, precisa e seletiva é de grande importância a fim de que possíveis não-conformidades sejam detectadas a tempo de se tornarem medidas corretivas antes que as mesmas acarretem riscos para o paciente, os quais podem se traduzir em ineficácia, toxicidade, eventualmente, em morte. Neste trabalho foi desenvolvido e validado um método rápido, preciso, seletivo, indicador de estabilidade para a quantificação da FNS na forma de cápsulas e um teste de dissolução para a quantificação in vitro de sua liberação no meio de dissolução para fins de avaliação da qualidade desses produtos em análise de rotina em laboratórios de controle de qualidade. / Finasteride (FNS) is a synthetic drug 4-azasteróide (azaandrost-1-ene-17-carboxamide, N-(1,1-dimethyl)-3-oxo-, (5 , 17 ), specific inhibitor of steroid Type II , 5 -reductase, an intracellular enzyme that converts testosterone to the more potent androgen 5 -dihydrotestosterone. FNS is classified as Class II (low solubility and high permeability) Biopharmaceutical Classification System (BCS). FNS is indicated for the treatment and control men with benign prostatic hyperplasia (BPH), prevention and treatment of prostate cancer and androgenetic alopecia some cases of hirsutism. Although the compounded drugs offer advantages with respect to ease dosage and more affordable, there are many obstacles that hinder the advancement of industry manipulation. The largest of these obstacles is the lack of credibility of the product handled by the supposed absence of a strict quality control of raw materials and finished products, lack of control of the production process and its reproducibility. To achieve a therapeutic goal expected, it must be noted that the drug concentration is indicated by the manufacturer to release the principle active in adequate amount and speed the therapeutic effect. There is no official monograph for quantification of FNS as pharmaceutical capsules or dissolution test. Therefore, to develop an analytical methodology for quantification of FNS in compounded capsules, which is quick, precise and selective is of great importance to ensure that potential non conformities are detected in time to make corrective measures before they can entail risks for the patient, which can translate into inefficiency, toxicity, eventually, death. This work was developed and validated a rapid, precise, selective, stability indicator for the quantification of NSF in the form of capsules and a dissolution test for in vitro quantification of their release into the dissolution medium for the purpose of assessing the quality of these products in routine analysis laboratory quality control.
644

Síntese de um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina (RAMMIP-BSA), para análise direta de clorpromazina em plasma por sistema de cromatografia líquida bidimensional

MORAES, Gabriel de Oliveira Isac 23 July 2012 (has links)
Um polímero de impressão molecular restrito à ligação de macromoléculas por meio de revestimento com albumina (do inglês “restrict access moleculary imprinted polymer coated with albumine” – RAM-MIP-BSA) foi sintetizado para a análise de clorpromazina em plasma humano por injeção direta em cromatografia líquida bidimensional. Primeiramente foram colocados no meio reacional o ácido metacrílico como monômero funcional, o etileno glicol dimetacrilato como agente de ligação cruzada, a 2,2 – azo isobutironitrila como iniciador radicalar, a clorpromazina como molécula modelo e o clorofórmio como solvente. O sistema foi mantido sob agitação por 60 minutos a 60°C. Depois, adicionou-se ao meio reacional hidróxi etil metacrilato e glicidil metacrilato como monômeros hidrofílicos. Após 24 h o polímero foi recolhido, lavado, tamisado e recoberto com albumina utilizando-se glutaraldeído como agente reticulante bifuncional. O RAM-MIP-BSA foi empacotado em uma pré-coluna de HPLC (high performance liquid chromatography) de 1 cm e sua capacidade de eliminação de macromolécula foi testada obtendo-se eliminação superior a 99%. Para os demais testes a pré-coluna foi utilizada em sistema de cromatografia líquida bidimensional. A amostra é injetada e as macromoléculas são eliminadas enquanto o analito é retido. Num segundo estágio o analito é eluído e conduzido para coluna analítica. Água ultrapura e uma solução de acetonitrila:tampão acetato de sódio 0,2 mol L-1 pH 4,1 45:55 (v/v) foram empregadas como fase de extração e fase móvel respectivamente. As análises foram executadas utilizando-se um detector UV/Vis a 313 nm. Para validação analítica da clorpromazina foi utilizando um pool de amostra de plasma humano de diferentes indivíduos voluntários, fortificadas em oito níveis de concentração, contemplando assim o intervalo terapêutico de 50-300 μg L-1 segundo a FDA. O método foi linear na faixa de 30-350 μg L-1, com r > 0,99 e limite de quantificação de 30,0 μg L-1. A precisão e exatidão intra-dias e inter-dias foram avaliadas com base no desvio padrão relativo (DPR) e no erro relativo (E) respectivamente e todos os resultados foram inferiores a 15% de acordo com a FDA. A recuperação foi de 80%. / A restrict access moleculary imprinted polymer coated with albumin (RAM-MIPBSA) has been synthesized and used for direct analysis of chlorpromazine from human plasma by using bidimensional liquid chromatography. The synthesis was carried out in three steps. First, methacrylic acid (functional monomer), ethylene glycol dimethacrylate (cross-linker), 2,2 azoisobutironitrile (initiator) and chlorpromazine were dissolved in chloroform and the mixture was maintained at 60°C during 60 min. In the second step, 2-hydroxy ethyl acrylate and glycidil (both hydrophilic co-monomers) were added into the flask and the synthesis was processed during 24h at 60°C. The obtained polymer was washed several times and coated with bovine serum albumin by using glutaraldehide as cross-linker. The material presented a macromolecules elimination ability larger than 99%. It was packed in a column (4.4 x 10 mm) and used in a column switching system. Deionized water and 45:55 (v/v) acetonitrile:sodium acetate buffer (pH=4.1) were employed as extraction solvent and mobile phase, respectively. The analytical curve was built using a human plasma pool of different volunteers, added with the drug in 8 different concentrations. The method has shown to be linear in the range from 30 to 350 mg L-1, with r >0.99 and quantification limit of 30 mg L-1. Precision and accuracy were evaluated by using relative standard deviation and relative error, respectively, and all the results are in accordance with FDA recommendations. Additionally, good recoveries and selectivity were also obtained.
645

Avaliação fotocatalítica de partículas semicondutoras baseadas em óxidos de zinco e cobalto obtidas por moagem de alta energia / Photocatalytic evaluation of semiconductor particles based on zinc and cobalt oxides obtained by high energy milling

DIAS, Jeferson Almeida 07 July 2015 (has links)
Corantes são compostos altamente nocivos aos recursos hídricos; assim, inúmeras técnicas vêm sendo desenvolvidas para o tratamento desses. A fotocatálise heterogênea é uma alternativa inovadora nesse aspecto, sobretudo no que se refere à utilização de materiais multicomponentes. O objetivo do presente trabalho foi obter semicondutores baseados em Óxidos de Zinco e Cobalto por meio de Moagem de Alta Energia e avaliar o potencial dos materiais obtidos na degradação fotocatalítica do corante Rodamina B. Após caracterizações físico-químicas dos pós precursores, foi realizada a moagem de alta energia a seco e a úmido (em álcool isopropílico) por 4 e 10 horas. Foi realizado tratamento térmico no sistema multicomponente a fim de compreender seus efeitos nas propriedades fotocatalíticas do material resultante. Os materiais moídos foram caracterizados via difração de raios X, com algumas amostras também avaliadas por análise térmica, Microscopia Eletrônica de Varredura e Espectroscopia de Energia Dispersiva; os ensaios de fotocatálise foram realizados em reator fotoquímico operante com radiação ultravioleta, enquanto os ensaios de adsorção em um reator fotoquímico operante no escuro. A presença de matéria orgânica residual ao processo de fotocatálise foi avaliada através do método de Análise de Oxigênio Consumido e a formação de subprodutos orgânicos através de Infravermelho por Transformada de Fourier. Os resultados indicaram que o pó do Óxido de Zinco precursor possui tamanho submicrométrico e o Óxido de Cobalto micrométrico. As fases cristalinas identificadas foram a Wurtzita e Espinélio para o óxido de Zinco e Cobalto, respectivamente, fases que persistem após a moagem. A redução no tamanho das partículas foi dependente das condições de moagem, sendo a amostra composta por óxidos de Zinco e Cobalto moída a úmido por dez horas a que apresentou cominuição mais efetiva. O tratamento térmico atuou na formação de uma solução sólida entre os óxidos trabalhados. Foi observado variação na atividade fotocatalítica para as várias condições investigadas, com tempos médios de meia vida do corante entre 7,6 e 165,0 minutos. No sistema composto por óxidos de Zinco e Cobalto, a amostra moída por dez horas a úmido apresentou valor médio para velocidade aparente de reação 56% maior que a mistura precursora. Os melhores resultados em fotocatálise, contudo, foram referentes ao Óxido de Zinco moído a seco por quatro horas, que apresentou velocidade aparente de reação 30% maior que o Óxido de Zinco precursor. Testes de adsorção não demonstraram tendência temporal da fisissorção do corante nos diferentes materiais. Os testes de Oxigênio Consumido e Infravermelho por Transformada de Fourier foram, de forma geral, concordantes entre si inferindo na mineralização do corante. / The dyes are dangerous compounds for the water environment; thus, numerous techniques have been developed for their treatment. The heterogeneous photocatalysis is a new alternative in this scope, especially in multicomponent systems. The aim of this research is to obtain semiconductors based on Zinc and Cobalt Oxides by the High Energy Ball Milling technique and evaluate the potential of the obtained materials to degrade Rhodamine-B dye. The physicochemical features of the starting materials were determined by different techniques of characterization. Dry milling was processed during 4 and 10 hours and wet milling (in isopropyl alcohol) at the same time. Heat-treatment was performed in the multicomponent system in order to correlate its effect in the materials properties. The obtained materials also were characterized by X-Ray diffraction; and some samples evaluated by thermal analysis, Scanning Electron Microscopy and Dispersive Energy Spectroscopy; and the photocatalytic tests were carried out in ultraviolet photochemical reactor and adsorption tests were performed in the dark. The presence of residual organic matter after the photocatalytic processes were evaluated by the Consumed Oxygen Analysis, as well as the formation of organic subproducts were evaluated by the Fourier Transform Infrared. The results indicate that the major part of raw Zinc Oxide showed particles in submicrometer size whereas the Cobalt Oxide presented the same feature basically in micrometric size. The crystallographic structures of the Wurtzite for Zinc Oxide and Spinel for Cobalt Oxides, and that these phases are the same that ones after the milling process. The heat-treatment was efficient to promote solid solution between the oxides applied in this work. The reduction in particle size was dependent of conditions of the milling; wherein the sample composed of Zinc and Cobalt oxides milled by ten hours in wet media showed the best result in comminution process. The major part of the materials presented photocatalytic activity, with half-life time between 7.6 and 165.0 minutes. Among the materials composed by Zinc and Cobalt oxides, the sample milled by ten hours in wet media presented average values for apparent reaction ratio 56% greater compared to the raw material blend. Nevertheless, pure Zinc Oxide milled the dry media during four hours presented the best results with apparent reaction ratio 30% greater compared to the raw Zinc Oxide. There were no temporal behavior of the dye’s physisorption on the materials evaluated by the adsorption tests. Generally speaking, the Oxygen Consumed technique and Fourier Transform Infrared tests were concordant with each other inferring in the mineralization of the dye. / Fundação de Amparo à Pesquisa do Estado de Minas Gerais - FAPEMIG
646

Inter-relações entre tratamento térmico, microestrutura e propriedades mecânicas em um aço ARBL.

William Marcos Muniz Menezes 20 December 2005 (has links)
O presente estudo foi desenvolvido com tratamentos térmicos de um aço de Alta Resistência e Baixa Liga - ARBL, contendo 0,11%C e outros elementos como Mn, Si, somando-se a adição de Nb como microligante. Os tratamentos térmicos contemplaram diversos roteiros de aquecimento e resfriamento, com austenitização plena e intercrítica. Os corpos-de-prova foram submetidos a ensaios de tração, dureza, fadiga e metalografia com microscopia óptica. Dessa forma puderam ser associadas propriedades mecânicas e textura do material, correlacionando-as com os tratamentos térmicos. O trabalho divide-se em duas etapas denominadas exploratória e direcionada. A etapa exploratória destinou-se a ampla avaliação da gama de propriedades que o aço poderia oferecer, e servir de base para uma etapa complementar denominada direcionada. A etapa direcionada utilizou-se como referência dos roteiros de tratamentos térmicos da etapa exploratória que resultaram em propriedades mecânicas de maior significância, reproduzindo tais tratamentos em parte, porém com alterações que apontavam no sentido de incrementar a resistência mecânica do aço. Todos os tratamentos térmicos envolveram têmpera do aço, porém devido ao baixo teor de carbono, fases como ferrita e carbetos compartilharam estruturas polifásicas com a martensita. A ocorrência de ferrita, perlita, bainita e martensita em diversos roteiros, caracterizam a microestrutura como multifásica. Apesar da ocorrência de martensita em ilhas, é na condição de martensita dispersa que foram obtidos os mais elevados valores de resistência mecânica, majorando-se em até cerca de 90% o limite de resistência médio previsto pelo fabricante, na condição de fornecimento.
647

High-altitude operations for a typical 70 - seat-regional jet.

Themis de Brito Abagge e Varella Gomes 29 April 2005 (has links)
Civil aircraft manufactures seek profitable subsonic transport category operations above 40.000 feet through new and advanced civil aircraft projects, in order to meet with modern airline needs. This is due to the increase of air traffic below this altitude, as well as lower operational cost, and more efficient engines above this altitude. The Federal Aviation Administration (FAA), responsible for certification of aeronautical products in the United States has adapted requirement 14 CFR 25.841(a) for high-altitude operations, based on the numerous executive jets that operate at altitude above 40.000 feet and have obtained their type cetificate based on special conditions1. Although the FAA is considering revising this regulation, there is not enough physiological substantiation to do so at this time. This way, aircraft with wing-mounted engines cannot fully comply with this requirement and petition for a exemption which is always required. A trade-off analysis of a typical 70-seater regional jet, with wing-mounted engines, for high altitude operation trends has been completed. Aspects such as operational and economical advantages, certification and compliance impacts were considered.
648

Desenvolvimento de um laser de CO2 contínuo, de alta potência e de alto fluxo.

Gilson Carlos de Castro Correard 17 November 2009 (has links)
Neste trabalho, são apresentados os detalhes do projeto, da construção e do desenvolvimento de um laser de CO2 de alto fluxo. O trabalho surgiu de necessidades específicas do Laboratório de Desenvolvimento de Aplicações de Laser e Óptica (DedALO) da Divisão de Fotônica do IEAv, onde é necessário um laser de CO2 contínuo, com potência da ordem de 1 kW e que possa ser operado como amplificador de um oscilador pulsado de baixa potência, para aplicações em processamento de materiais, propulsão a laser e evaporação de metais utilizados nos projetos de separação isotópica. Por meio de estudos teóricos e observações práticas, procurou-se reunir o maior número de dados disponíveis para a montagem de lasers de CO2 de alto fluxo. São apresentados os detalhes de projeto da cavidade ressonante, do trocador de calor, resistor ballast, sistema de vácuo, sistema elétrico e sistema de fluxo. São também descritos os componentes, a sua montagem, técnicas de alinhamento de espelhos, medição de potência e de fluxo. Com o primeiro protótipo foram obtidos 200 W de potência contínua, uma eficiência de conversão de energia elétrica em óptica de 13%, quando operando com uma pressão ótima de 24 Torr (3200 Pa) de uma mistura padrão de 10% de CO2, 10% de N2, 80% de He, com uma vazão de 0,121 m3/s. Estes resultados são comparados com os previstos pelos modelos utilizados e é verificada uma boa concordância entre eles.
649

Análise e otimização dos processos de fresamento a altas velocidades no contexto de ferramentaria.

Pedro Jorge Moreira de Abreu 21 December 2010 (has links)
Este trabalho tem como objetivo avaliar e melhorar os métodos de fabricação de superfícies complexas. Para tanto, diferentes estratégias de fresamento são analisadas e aplicadas em um contexto de ferramentaria. As metas de melhoria são: diminuição dos tempos de processo, preservação dos recursos produtivos e melhora da qualidade superficial da peça usinada. São consideradas as operações de desbaste, semi-acabamento e acabamento do aço H13 temperado. A escolha desse material, bem como das ferramentas e da máquina ferramenta apresentadas neste estudo, é baseada nos recursos existentes e utilizados por empresas estabelecidas em território nacional. A peça de estudo foi sugerida por uma ferramentaria renomada e possui características presentes em seus atuais produtos. Características essas, que apresentam-se como pontos críticos no processo de manufatura em virtude de sua complexidade geométrica. Os objetivos estabelecidos foram alcançados. Foram desenvolvidas estratégias que permitiram o aumento da produtividade, ampliação da vida útil de ferramentas e máquinas e diminuição dos índices de rugosidade das superfícies fabricadas. Todos os conceitos foram empregados em chão-de-fábrica onde houve a comprovação dos ganhos obtidos e da aplicabilidade do estudo.
650

Avaliação de fluidos de corte emulsionáveis no fresamento de liga de alumínio 7050-T7451 a altas velocidades de corte.

Fabrício Fernandes Riquelme 22 December 2010 (has links)
Fluidos de corte são utilizados pela indústria metal-mecânica no processo industrial de usinagem, aplicados sempre sobre a interface ferramenta de corte e material da peça. Os principais tipos de fluidos de corte utilizados nos processos de usinagem são os óleos integrais, constituídos basicamente de óleos graxos e óleos minerais, e as emulsões, que são misturas de água com óleos de base vegetal, mineral ou sintética. Para manter a estabilidade de uma emulsão, são utilizados emulgadores que solubilizam na água e, por diferença de polaridade, homogeneízam as gotículas de óleo na mistura. Desse modo, garante-se o aumento da lubricidade, pela presença de óleo, e a capacidade de refrigeração e limpeza de cavacos da região de corte, pela presença de água. O desafio atual é estabelecer os critérios de avaliação de emulsões considerando estabilidades físicas, químicas e bacteriológicas. Em uma primeira análise, considerando apenas o aspecto tecnológico do processo de usinagem, uma emulsão de melhor desempenho pode ser definida como aquela que provoca uma vida útil mais longa da ferramenta de corte sem a respectiva degradação do fluido. Este trabalho teve o objetivo de avaliar o desempenho de fluidos de corte emulsionáveis no processo de fresamento de ligas de alumínio 7050-T7451 a altas velocidades de corte. Os critérios de avaliação foram subdivididos em rendimentos quanto à usinabilidade e características dos fluidos emulsionáveis. Três fluidos foram submetidos a uma bateria de testes de usinagem e laboratórios. Os resultados de usinabilidade demonstraram a significativa influência que o fluido exerce principalmente na vida de ferramenta e no acabamento de superfície usinada e os resultados laboratoriais revelaram o desafio ainda não solucionado de se obter um fluido com alta resistência à degradação e que ao mesmo tempo propiciem a isenção de névoa, espuma e corrosão.

Page generated in 0.0757 seconds