41

Transformador óptico por interferometria de luz branca para medição de altas tensões. / Optical voltage transformers using white light interferometry for high voltage measurements.

Silva, Luiz Pinheiro Cordovil da 26 January 2006 (has links)
No presente trabalho é apresentada uma nova abordagem para medida de potenciais em altos níveis de tensão que utilizam sensores eletro-ópticos Pockels. Também descreve a aplicação da técnica de interferometria de luz branca em sistemas de alta tensão por fibras ópticas. Neste sistema a informação é codificada no espectro da luz, permitindo assim que a medida seja independente da potência óptica transmitida pelo link de fibras ópticas. Um protótipo foi construído e testado sob excitação de tensão a.c. até 20 kV em 60 Hz mostrando boa resposta e demonstrando a viabilidade deste método. / A new approach to perform measurement of potentials in high voltage levels using electrooptical Pockels sensors is presented here. This work describes an application of the White Light Interferometry technique to a high voltage optical fiber measurement system. In this system the information is encoded in the spectrum of the light, allowing the measurement to be independent of the optical power transmitted by the optical fiber link. A prototype was built and tested under excitation of a.c. voltages up to 20 kV in 60 Hz showing good response and demonstrating the feasibility of this method.
42

Efeito de interferência quântica no transporte eletrônico de dispositivos "quasi"-unidimensionais / Effect of quantum interference on the electronic transport of "quasi" -dimensional devices

OLIVEIRA, Alexandre de Souza 03 May 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-07-19T13:43:10Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_efeitointerferenciaquantica.pdf: 12845239 bytes, checksum: f75732419727d0f0958b1bf68e6991a9 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-07-19T13:43:58Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_efeitointerferenciaquantica.pdf: 12845239 bytes, checksum: f75732419727d0f0958b1bf68e6991a9 (MD5) / Made available in DSpace on 2018-07-19T13:43:58Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_efeitointerferenciaquantica.pdf: 12845239 bytes, checksum: f75732419727d0f0958b1bf68e6991a9 (MD5) Previous issue date: 2018-05-03 / PROPESP/UFPA - Pró-Reitoria de Pesquisa e Pós-Graduação / O estudo de transporte eletrônico em nano dispositivos tem se mostrado de grande relevância nos últimos anos, desde o trabalho de Aviran e Ratner, baseado nas propriedades de condutividade elétrica em moléculas individuais retificadoras sob ação de um campo elétrico externo. Os polímeros orgânicos conjugados no estado puro apresentam baixa condutividade, mas quando dopados, tratados com agentes oxidantes redutores ou conectados a eletrodos de ouro (Au) e submetidos a um campo elétrico externo, passam a ter um comportamento do tipo metálico, isto é, com alta condutividade em consonância com trabalhos experimentais. Nesta pesquisa foram utilizados dispositivos constituídos de polímeros orgânicos conjugados no estado puro e também dopados com cadeias contendo ligações do tipo simples () e duplas ( −), alternadas entre os carbonos e estes ligados somente a átomos de hidrogênio com eletrodos de ouro (Au) conectados nas extremidades das moléculas individuais. Este estudo foi proposto para dois tipos de eletrodos: em forma de pirâmide e plano. Os dispositivos modelos foram otimizados através da Teoria de Hückel Estendido (THE) e o cálculo do transporte eletrônico foi realizado usando THE combinada com a Função de Green de Não-Equilíbrio (FGNE). Estes dispositivos são estruturas “quasi-1D” ou aproximadamente lineares e foram divididos em dois grupos: o primeiro, com quantidades ímpares de átomos de carbonos a partir de cinco (5) até dezenove (19) átomos de carbono em sua molécula individual (Grupo 1) e o segundo, com quantidades pares iniciando em seis (6) indo até vinte (20) átomos de carbono em sua molécula individual (Grupo 2). Os dispositivos foram submetidos a duas condições: em baixa tensão, variando de 0 até 0,1 Volt e em seguida a alta tensão, de 0 a 1,0 Volt. Para efeito de comparação das curvas de corrente – tensão (I-V) e condutância diferencial – tensão (G-V) entre os resultados de baixa e alta tensão, foram utilizados o mesmo intervalo de tensão, ou seja, de 0 até 0,1 Volt. Para este trabalho, foram analisados os efeitos de interferência quântica destrutiva (IQD), assim como de interferência quântica construtiva (IQC). Os efeitos de IQD são produzidos devido a anti-ressonância na transmitância evidenciadas por estados não acessados observados nos picos de transmissão não permitindo que o transporte ocorra sem apresentar oscilações na curva de condutividade. / The study of electronic transport in nano devices has been of great relevance in the last years, since the work of Aviran and Ratner, based on the properties of electrical conductivity in individual rectifying molecules under the action of an external electric field. The organic conjugated polymers in the pure state have low conductivity, but when doped, treated with reducing agents or connected to gold electrodes (Au) and subjected to an external electric field, they have a metallic behavior, that is, with high conductivity in line with experimental work. In this research we used devices composed of organic polymers conjugated in the pure state and also doped with chains containing simple (σ) and double (σ-π) type bonds, alternating between the carbons and these bound only to hydrogen atoms with gold electrodes (Au) connected at the ends of the individual molecules. This study was proposed for two types of electrodes: pyramid and plane. The model devices were optimized through the Extended Hückel Theory (EHT) and the computation of the electronic transport was performed using EHT combined with the Non-Equilibrium Green Function (NEGF). These devices are either quasi-1D or approximately linear structures and have been divided into two groups: the first, with odd numbers of carbon atoms from five (5) to nineteen (19) carbon atoms in their individual molecule (Group 1) and the second, with even numbers starting at six (6) going up to twenty (20) carbon atoms in its individual molecule (Group 2). The devices were subjected to two conditions: at low voltage, ranging from 0 to 0.1 Volt and then to high voltage, from 0 to 1.0 Volt. In order to compare the current and voltage (I - V) curves and the differential - voltage conductance (G - V) between low and high voltage results, the same voltage range was used, that is, from 0 to 0.1 Volt. For this work, the effects of destructive quantum interference (DQI) as well as constructive quantum interference (CQI) were analyzed. The effects of DQI are produced due to anti-resonance in the transmittance evidenced by unaccessed states observed in the transmission peaks, not allowing the transport to occur without presenting oscillations in the conductivity curve.
43

Transformador óptico por interferometria de luz branca para medição de altas tensões. / Optical voltage transformers using white light interferometry for high voltage measurements.

Luiz Pinheiro Cordovil da Silva 26 January 2006 (has links)
No presente trabalho é apresentada uma nova abordagem para medida de potenciais em altos níveis de tensão que utilizam sensores eletro-ópticos Pockels. Também descreve a aplicação da técnica de interferometria de luz branca em sistemas de alta tensão por fibras ópticas. Neste sistema a informação é codificada no espectro da luz, permitindo assim que a medida seja independente da potência óptica transmitida pelo link de fibras ópticas. Um protótipo foi construído e testado sob excitação de tensão a.c. até 20 kV em 60 Hz mostrando boa resposta e demonstrando a viabilidade deste método. / A new approach to perform measurement of potentials in high voltage levels using electrooptical Pockels sensors is presented here. This work describes an application of the White Light Interferometry technique to a high voltage optical fiber measurement system. In this system the information is encoded in the spectrum of the light, allowing the measurement to be independent of the optical power transmitted by the optical fiber link. A prototype was built and tested under excitation of a.c. voltages up to 20 kV in 60 Hz showing good response and demonstrating the feasibility of this method.
44

Estudo de controle e proteção para sistemas de transmissão HVDC multiterminais baseados em conversores modulares multiní­veis. / Control and protection study of multiterminal HVDC transmission systems based on modular multilevel converters.

Nayara Yuko Suzuki 28 June 2018 (has links)
O crescente interesse por sistemas de transmissão do tipo VSC-based HVDC (VSCHVDC) como alternativa aos atuais tem levado à necessidade de estudos sobre o principal desafio associado à sua implantação, que é o desenvolvimento de um esquema de proteção que seja rápido e que identifique a zona de proteção na qual uma eventual falta tenha ocorrido, respeitando-se assim o princípio de seletividade. Para estudo de um sistema de proteção que atenda a estes requisitos, foi utilizada neste trabalho uma rede com quatro terminais e transmissão High-Voltage Direct Current (HVDC), implementada com conversores modulares multiníveis (Modular Multilevel Converter (MMC)) e simulada em situações de contingência. Grandezas medidas nos elos de Corrente Contínua (CC) ligados a um dos terminais foram utilizadas para identificar a ocorrência de uma contingência na rede e então para decidir se trata-se de uma falta interna à zona de proteção considerada na análise. Para classificar as faltas em interna ou externa, observaram-se os espectros dos sinais de tensão CC em um terminal, calculados sobre uma janela do sinal através de Fast Fourier Transform (FFT), para várias situações de falta. Destes espectros, notou-se que uma característica varia de acordo com a distância da falta até o terminal, com o fato de a falta ser interna ou externa e com a resistência de falta. Através desta característica, denominada aqui \"frequência de centro de massa\", foi possível distinguir as faltas internas com resistências de falta baixas do restante dos eventos testados. Considerando-se apenas este parâmetro, não foi possível classificar corretamente faltas internas com resistência de falta muito alta. / The growing interest in VSC-based HVDC (VSC-HVDC) transmission systems as an alternative to the current ones has required studies about the the main challenge associated with its application, which is the development of a protection scheme that is able to both fast and efficiently determine the protection zone where a fault may have happened so as to achieve selectivity. In order to study a protection system that complies with those requirements, a High-Voltage Direct Current (HVDC) transmission system with four terminals implemented with Modular Multilevel Converter (MMC) converters was simulated under contingency condition. Electrical quantities measured in one of the terminal\'s Direct Current (DC) links were used to determine the occurrence of a fault event in the system, as well as to decide whether that event belonged to the protection zone considered in the analysis. Spectra obtained via Fast Fourier Transform (FFT) over a window of the DC voltage measured in one of the terminals were observed in order to discriminate between internal and external fault events. From these observations, it was noticed that a certain characteristic, named here \"center of mass frequency\", varies according to the distance between the fault location and the terminal, fault resistance, as well as whether that the fault is either internal or external to the analysed protection zone. By using this characteristic, it was possible to tell internal faults with low resistance fault from other events. Considering this parameter only, it was not possible to correctly classify internal faults with high fault resistance.
45

Caracterização e desenvolvimento de sensores ópticos de corrente elétrica para aplicações em linhas de alta tensão

SANTA BRÍGIDA, Angela Costa 03 April 2017 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-07-03T18:44:46Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_CaracterizacaoDesenvolvimentoSensores.pdf: 4867708 bytes, checksum: 9c430ec1e788fb2f788ed5f2dee7409f (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-08-09T14:38:21Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_CaracterizacaoDesenvolvimentoSensores.pdf: 4867708 bytes, checksum: 9c430ec1e788fb2f788ed5f2dee7409f (MD5) / Made available in DSpace on 2017-08-09T14:38:21Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_CaracterizacaoDesenvolvimentoSensores.pdf: 4867708 bytes, checksum: 9c430ec1e788fb2f788ed5f2dee7409f (MD5) Previous issue date: 2017-04-03 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Esta tese, intitulada “Caracterização e desenvolvimento de sensores ópticos de corrente elétrica para aplicações em linhas de alta tensão” foi desenvolvida no âmbito de um programa de doutorado em Engenharia Elétrica. Foram implementados e caracterizados sensores de corrente magneto-óptico, para aplicações de medição e proteção em sistemas de alta potência, nomeadamente, prisma sensor e sensor com fibra de cristal fotônico (PCF). Ambos, são baseados no efeito Faraday, utilizando uma configuração polarimétrica em dupla quadratura. Este trabalho foi, então, dividido, em dois momentos. No primeiro, um prisma sensor, constituído de uma cabeça sensora portátil para ancoragem na linha de transmissão foi desenvolvido, em Portugal, para uma aplicação industrial. Neste caso, no protótipo do prisma sensor foi utilizado um prisma de vidro Schott SF57 de 8cm de comprimento com alta constante de Verdet e baixa birrefringência. Ele foi incorporado em um invólucro de Nylon adequado para aplicações de fixação na linha de alimentação. A operação do sensor é caracterizada e comparada usando Diodos Super Luminescentes (SLD) distintos como fontes ópticas, com emissão a 650, 830 e 1550 nm. O sensor demonstrou precisão de classe 1, para correntes nominais iguais ou superiores a 900 ARMS e classes 0,1 e 0,2 para correntes nominais de 1,2 kARMS e 0,3 kARMS, respectivamente, e a possibilidade de detectar impulsos na rede abaixo dos 10 μs. Em um segundo momento, outra configuração envolveu o uso de fibras ópticas como elemento transdutor, empregando, fibras torcidas altamente birrefringente com 4,5, 6, 9, e 11 rotações por segundo, desenvolvidas pelo grupo do Laboratório de Fibras Especiais & Materiais Fotônico – LaFE, do Instituto de Física Gleb Wataghin da UNICAMP, no Brasil. Em particular, estas fibras foram testadas enrolando-as em torno de um condutor elétrico utilizando três tamanhos de enrolamento de 6, 12 e 18 cm de diâmetros com diferentes voltas, com correntes de até 800 ARMS usando uma fonte SLD a 650 nm. Parâmetros, tais como a sensibilidade e a linearidade do sensor, foram investigados. Uma simulação também foi realizada para analisar quantitavamente o valor da sensibilidade das fibras com relação ao número de voltas e com relação ao diâmetro do suporte, no qual foi concluído que deve haver um compromisso entre estes dois parâmetros afim de obter uma melhor resposta no sinal de saída do sensor. / This thesis, titled "Characterization and development of electric sensors for electrical applications in high voltage lines" was developed in a PhD program in Electrical Engineering. Fix the devices and characterized the magneto-optical current sensors for measurement applications and protection in high power systems, namely, prism sensor and photonic glass fiber (PCF) sensor. Both are based on the Faraday effect, using a double quadrature polarimetric configuration. This work was then divided in two moments. In the first, a prism sensor, consisting of a portable sensor head for anchoring in the transmission line was developed, in Portugal, for an industrial application. In this case, no prism sensor prototype was used in a Schott SF57 glass prism 8cm in length with high Verdet constant and low birefringence. It has been incorporated into a Nylon casing suitable for fastening applications in the power line. The operation of the sensor is characterized and compared using Super Luminescent Diodes (SLD) as a source of 650, 830 and 1550 nm. Class 1 precision sensor for nominal currents of 900 ARMS or higher and classes 0,1 and 0,2 for nominal currents of 1,2 kARMS and 0,3 kARMS, respectively, and the possibility of detecting impulses in the network of 10 Μs. Second, another type of wrapping, the use of optical fibers as a transition element, using highly rotated fibers at 4, 6, 9, and 11 revolutions per second, developed by the group of the Laboratory of Special Fibers and Photonic Materials - LaFE, from the Institute of Physics Gleb Wataghin of UNICAMP, Brazil. In particular, these lines were tested as a whole on an electric conductor using three winding sizes of 6, 12 and 18 cm in diameters with different turns, with currents of up to 800 ARMS using an SLD source at 650 nm. Parameters, such as sensitivity and linearity of the sensor, were investigated. A symbolic analysis was also performed to quantitatively analyze the fiber sensitivity value with respect to the number of turns and with respect to the diameter of the support, there is no conclusion that there is a compromise between these two parameters in order to obtain a better response in the signal of sensor output.
46

Conversor CC-CC isolado baseado no Conversor Modular Multiníveis (MMC) e em retificador multipulsos

Lambert, Gustavo 20 February 2015 (has links)
Made available in DSpace on 2016-12-12T20:27:38Z (GMT). No. of bitstreams: 1 Gustavo - resumo.pdf: 113712 bytes, checksum: 27db7bf493a7ed5908ba1c41f72bbaa8 (MD5) Previous issue date: 2015-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Essa dissertação apresenta um novo conversor CC-CC para sistemas de elevada tensão e alta potência. O foco de aplicação desse conversor são sistemas de transmissão ou de distribuição não convencionais. A estrutura do conversor apresentado opera em dois estágios, entre os quais a isolação é obtida através de transformador operado em média frequência. A referida estrutura do conversor é composta por um inversor operando como fonte de corrente trifásica balanceada acionando um retificador multipulsos. Dentre as possíveis variações o trabalho concentra os esforços na análise de um MMC (Modular Multilevel Converter) como um inversor e em um retificador de 12 pulsos do tipo série no segundo estágio, o transformador defasador escolhido para o último possui conexões YYΔ. As análises qualitativas do conversor apresentam características como a circulação de correntes no MMC e o cancelamento de harmônicos feito pelo retificador alimentado em corrente. Com foco na operação em malha fechada é realizada a modelagem do inversor desacoplada do retificador de 12 pulsos e vice-versa. Através das equações que descrevem cada elemento e com as devidas considerações são apresentadas as funções de transferência para a estratégia de controle adotada, ou seja, controle da tensão de saída e das variáveis internas do MMC. A validação dos controladores e do sistema de supervisão proposto é realizada através dos resultados de simulação e posteriores resultados experimentais em um conversor com escala reduzida de potência e tensão.
47

Alterações topológicas para reduzir a propagação de falhas na rede elétrica de alta tensão brasileira / Topological changes to prevent failure propagation on the Brazilian power transmission lines

Paiva, William Roberto de, 1986- 24 August 2018 (has links)
Orientadores: André Franceshi de Angelis, José Geraldo Pena de Andrade / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia / Made available in DSpace on 2018-08-24T15:13:51Z (GMT). No. of bitstreams: 1 Paiva_WilliamRobertode_M.pdf: 3222455 bytes, checksum: 4ba3e5407135ec1d8483e94ec4c11749 (MD5) Previous issue date: 2014 / Resumo: Neste trabalho, propõe-se a avaliação de quatro métodos que possam melhorar a resiliência de redes de alta tensão através da adição de linhas de transmissão, utilizando-se a Teoria das Redes Complexas. Criou-se um modelo da rede brasileira de geração e transmissão de energia elétrica em forma de grafo para testar os métodos. O primeiro deles consiste em ligar pares de vértices que possuam menor grau em toda a rede. O segundo liga os vértices de menor betweenness. O terceiro efetua ligações entre pares de vértices de menor grau que estejam ligados aos vértices de maior carga em toda a rede. O último, faz ligações entre os dois vértices de betweenness mediano. Todos os métodos foram testados com e sem o auxílio do procedimento "min-cut", capaz de identificar as arestas que, ao serem removidas, dividem a rede em duas sub-redes, permitindo assim efetuar ligações que reduzam o risco dessa divisão. Além dos testes no modelo da rede brasileira, utilizaram-se também 1000 redes Scale-Free e 1000 aleatórias para verificar o aumento de eficiência trazidos. Todos os métodos foram capazes de aumentar a eficiência, tanto no modelo da rede real quanto nos modelos artificiais. A estratégia de ligar os vértices de betweenness mediano com auxílio do min-cut trouxe o maior aumento. A resiliência da rede, diante de falhas planejadas e falhas aleatórias, foi aumentada em poucos casos, porém, em nenhum houve redução da mesma. Conclui-se que as estratégias propostas podem ser utilizadas para melhorar a eficiência de redes de alta tensão, mantendo ou aumentando sua resiliência, bem como podem ser usadas para trazer os mesmos atributos para redes complexas em geral / Abstract: In this work we purpose to assess four methods to improve high-voltage networks resilience against failures and attacks, using the Complex Network Theory to do it. To test these methods, we created a network model in graph format, based on the Brazilian generation and transmission electrical network. The first of these methods consist in to link pairs of nodes which have the lowest degree in the network. The second creates a link betweenn the lowest betweenness nodes. The third method is to link the two lowest degree nodes which are linked to the highest load nodes. The last one creates a link betweenn the two nodes which has the median betweenness. All methods were tested with and without the use of the "min-cut" procedure. This procedure finds the lowest number of necessary links that, when removed, divide the network in two sub-networks. It allows us to identify these links and reduce the risk of this partitioning the network by adding new links. We also test the strategies in 1000 artificial Scale-Free networks and 1000 artificial Random networks to validate those methods. All strategies were able to increase efficiency, in the real and artificial networks models. The strategy which links the median betweenness nodes using the "min-cut" procedure brought the best results. The network resilience against planned and random failures was increased in in few cases, but no decreases was registered. We conclude that our strategies can be used to improve high-voltage network efficiency, keeping or improving its resilience, as they can be used to bring the same attribute to any type of complex networks / Mestrado / Tecnologia e Inovação / Mestre em Tecnologia
48

Projeto de transdutor de corrente elétrica para alta tensão com nova abordagem de detecção magnetostritiva e sensoriamento óptico, utilizando Terfenol-D e grade de Bragg em fibra óptica / High voltage electric current transducer project, with innovative approach for magnetostrictive modulation and optical sensing using Terfenol-D and fiber Bragg gratings

Cremonezi, Alcides Oliveira 08 December 2011 (has links)
Orientador: Elnatan Chagas Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T01:27:01Z (GMT). No. of bitstreams: 1 Cremonezi_AlcidesOliveira_M.pdf: 4474466 bytes, checksum: 5a33efaeb2ab330c00861ab393b6c732 (MD5) Previous issue date: 2011 / Resumo: Os sensores a fibra óptica são imunes à interferência eletromagnética (EMI), eles são normalmente encontrados em ambientes eletricamente ruidosos, especialmente em linhas de transmissão de alta voltagem. Essa é a característica principal que faz desse tipo de sensores ideais para empresas de Energia Elétrica. Esse trabalho apresenta uma nova abordagem, de precisão moderada, robusta e de baixo custo, para a fabricação de um transdutor de corrente elétrica para alta tensão, com detecção magnetostritiva utilizando material inteligente, Terfenol-D, e sensoriamento óptico através de grade de Bragg em fibra óptica (FBG). O núcleo magnético foi desenvolvido em formato toroidal e construído utilizando usinagem através de eletro-erosão, o que resultou em uma peça única com projeto mecânico robusto. Aplicando compressão mecânica ao sensor toroidal e fazendo sua resposta ficar muito próxima a uma função quadrática, foi possível calcular o valor RMS da corrente diretamente do sinal de saída do sensor, e com isso, eliminar qualquer polarização magnética DC utilizada em técnicas anteriores reportadas na literatura. Foi utilizada com sucesso, uma nova técnica de circuito eletrônico de interrogação que permite a medida de sinais AC e mantém o ponto de operação DC da FBG. Resultados experimentais medidos com o transdutor óptico desenvolvido mostraram que entre correntes de aproximadamente 200 a 900A o erro observado foi de apenas 1,2% e sua dependência com a temperatura dentro de um range de 25 a 450C mostrou erro máximo de 2%. O sistema desenvolvido apresenta rápida resposta a transiente e precisa de somente 34ms para alcançar o estado estacionário quando submetido a um aumento de 150% da corrente nele medida. Os resultados mostram que o projeto sugerido é adequado e muito promissor para a construção comercial de um transdutor óptico de corrente para alta tensão / Abstract: Optical sensors are passives and immunes to electromagnetic interferences (EMI), they are well suited for applications in electrically noisy environments, especially in high voltages transmission lines. This is the main characteristic that makes them ideal to electrical energy companies. A new approach to the fabrication of, moderated precision, robust and low-cost fiber Bragg gratings (FBG) optical current transducers using a Terfenol-D magnetostrictive smart material is presented. Electro-erosion was used to manufacture a magnetic core in a toroidal shape which resulted in a single piece robust mechanical design. By applying mechanical compression to the toroidal sensor and making its response very close to a quadratic function, it is possible to calculate the RMS value of the current directly from the output of the sensor and eliminate the DC biasing magnetic field used in previous literature reported techniques. A new electronic interrogation circuit technique which allows the measurement of AC signals and keeps the DC operation point of the FBG was implemented and successfully used in the prototype. Experimental results measured in the developed optical current transducer showed that an error of 1.2% was achieved for currents over approximately the 200 to 900A range and its temperature dependence in a range of 25 to 450C has showed a maximum error of 2%. The developed system presents a fast transient response, and needs only 34ms to reach the steady state after a 150% amplitude step increase is applied to current being measured. The results shows that the developed project is feasible and also very promisor to be considered on commercial applications / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
49

Análise de modelos e aplicação do UPFC em sistema de 138 kV. / Models analysis and application of UPFC in 138 kV system.

Tokuno, Stanley Eidi 29 July 2016 (has links)
Este trabalho trata do UPFC (Unified Power Flow Controller), que corresponde a um dos mais promissores dispositivos FACTS de última geração, pois apresenta a capacidade de controle independente de todos os parâmetros básicos do sistema elétrico de potência (tensão, impedância e ângulo de fase). Com base nos modelos já propostos para representação deste equipamento em regime permanente, é realizada análise e proposta de um modelo que permite uma abordagem prática, para simulação do UPFC em softwares de fluxo de potência comerciais que não possuem modelos dedicados para este dispositivo. São revisitados os conceitos associados ao UPFC, com apresentação dos modelos analisados e seus respectivos parâmetros, assim como os equipamentos instalados e estimativa de custos para implantação. Através de simulações utilizando o modelo de transformador ideal associado à impedância do transformador série e compensador estático, são obtidos os parâmetros para o modelo de injeção de potências e realizadas simulações que demonstram a equivalência entre estes modelos. Finalmente, é realizada a análise de aplicação do UPFC em um sistema de distribuição de alta tensão, onde há forte presença de geração distribuída com sua sazonalidade característica e linhas que realizam a interligação entre diferentes fontes do sistema, havendo a necessidade de controle do fluxo de potência e melhoria dos níveis de tensão em função dos critérios técnicos e aspectos regulatórios. / This work is about UPFC which corresponds to one of the most promising last generation FACTS device, for it presents independent control in all basic parameters of the electrical power system (voltage, impedance and phase angle). Based on models that have already been proposed to represent this equipment in steady state, an analysis has been made and a model that permits practical approach is proposed to simulate the UPFC in commercial power flow softwares that do not yet support this device. The associated UPFC concepts are revisited with the presentation of analyzed models and their respective parameters as well as the installed equipments and cost estimate for implementation. Through simulations using ideal transformer associated to the series transformer impedance and static Var compensator model, parameters are obtained for the power injection model and simulations were run that showed a similarity between these models. Finally, a UPFC application analysis was done for a region of high voltage distribution system, where there is a strong presence of distributed generation typically seasonal and lines which connect different sources of the system, having the necessity of controlling the power flow and improvement of the voltage levels due to the technical criteria and regulatory aspects.
50

Análise de modelos e aplicação do UPFC em sistema de 138 kV. / Models analysis and application of UPFC in 138 kV system.

Stanley Eidi Tokuno 29 July 2016 (has links)
Este trabalho trata do UPFC (Unified Power Flow Controller), que corresponde a um dos mais promissores dispositivos FACTS de última geração, pois apresenta a capacidade de controle independente de todos os parâmetros básicos do sistema elétrico de potência (tensão, impedância e ângulo de fase). Com base nos modelos já propostos para representação deste equipamento em regime permanente, é realizada análise e proposta de um modelo que permite uma abordagem prática, para simulação do UPFC em softwares de fluxo de potência comerciais que não possuem modelos dedicados para este dispositivo. São revisitados os conceitos associados ao UPFC, com apresentação dos modelos analisados e seus respectivos parâmetros, assim como os equipamentos instalados e estimativa de custos para implantação. Através de simulações utilizando o modelo de transformador ideal associado à impedância do transformador série e compensador estático, são obtidos os parâmetros para o modelo de injeção de potências e realizadas simulações que demonstram a equivalência entre estes modelos. Finalmente, é realizada a análise de aplicação do UPFC em um sistema de distribuição de alta tensão, onde há forte presença de geração distribuída com sua sazonalidade característica e linhas que realizam a interligação entre diferentes fontes do sistema, havendo a necessidade de controle do fluxo de potência e melhoria dos níveis de tensão em função dos critérios técnicos e aspectos regulatórios. / This work is about UPFC which corresponds to one of the most promising last generation FACTS device, for it presents independent control in all basic parameters of the electrical power system (voltage, impedance and phase angle). Based on models that have already been proposed to represent this equipment in steady state, an analysis has been made and a model that permits practical approach is proposed to simulate the UPFC in commercial power flow softwares that do not yet support this device. The associated UPFC concepts are revisited with the presentation of analyzed models and their respective parameters as well as the installed equipments and cost estimate for implementation. Through simulations using ideal transformer associated to the series transformer impedance and static Var compensator model, parameters are obtained for the power injection model and simulations were run that showed a similarity between these models. Finally, a UPFC application analysis was done for a region of high voltage distribution system, where there is a strong presence of distributed generation typically seasonal and lines which connect different sources of the system, having the necessity of controlling the power flow and improvement of the voltage levels due to the technical criteria and regulatory aspects.

Page generated in 0.0846 seconds