• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 1
  • Tagged with
  • 22
  • 17
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelo de calibração beta

CAVALCANTE, Mileno Tavares 31 January 2013 (has links)
Submitted by Danielle Karla Martins Silva (danielle.martins@ufpe.br) on 2015-03-12T12:55:45Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Cavalcante_2013_Modelo de Calibração Beta.pdf: 1287396 bytes, checksum: 4e58b1ff2a09bfb84e58587aa92cd49c (MD5) / Made available in DSpace on 2015-03-12T12:55:45Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Cavalcante_2013_Modelo de Calibração Beta.pdf: 1287396 bytes, checksum: 4e58b1ff2a09bfb84e58587aa92cd49c (MD5) Previous issue date: 2013 / O presente trabalho discute o problema de calibração em química analítica no contexto de não linearidade dos dados. A hipótese principal e que a media da variável resposta está restrita ao intervalo (0; 1) e pode ser modelada por uma distribuição beta, de modo similar ao modelo de regressão beta (Ferrari e Cribari-Neto, 2004). O objetivo _e propor uma extensão do modelo de regressão beta a estudos de calibração e verificar as propriedades de seu estimador para a concentração do analítico x comparativamente aos modelos linear e quadrático, que supõe resíduos normalmente distribuídos com variância constante. Aplicações a dados reais para os modelos considerados são apresentadas.
2

Dispositivo para medição e teste de transmitância luminosa e semafórica em óculos de sol de acordo com a norma brasileira - ABNT NBR ISO 12312-1:2015 / Device for luminous and traffic lights transmittance evaluation in sunglasses according Brazilian Standard - ABNT NBR ISO 12312-1:2015

Artur Duarte Loureiro 06 November 2017 (has links)
A classificação por categoria de 0 a 4 para óculos de sol determina quão claras ou escuras são suas lentes. A norma brasileira, ABNT NBR ISO 12312-1, exige, entre outros requisitos, testes de transmitância da luz visível em óculos de sol (categoria), para que estes sejam classificados como adequados ou não para direção de automóveis. Medidas do grau de escurecimento das lentes de um par de óculos de sol e da atenuação luminosa das luzes de sinais semafóricos são testes propostos para este item da norma. Porém, o público, em geral, não possui meios de testar seus próprios óculos. Um teste padrão de transmitância é trabalhoso, demorado e requer um espectrofotômetro e um profissional treinado. O objetivo deste trabalho é desenvolver um dispositivo portátil capaz de realizar testes de transmitância luminosa e semafórica de acordo com a norma brasileira sendo rápido, preciso e intuitivo, realizando os testes de forma automática sem exigir do usuário qualquer treinamento prévio. Diferentemente dos dois sistemas anteriormente desenvolvidos no Laboratório de Instrumentação Oftálmica (LIO), para testes de transmitância, este dispositivo é embarcado e atende à norma atual lançada em 2015, que não estava em vigor na época em que os demais foram desenvolvidos. O desafio para se construir um sistema embarcado é a combinação de fontes luminosas e sensores necessária para se obter padrões espectrais similares aos da norma. Foi desenvolvido e construído um protótipo microcontrolado usando a combinação de um LED branco com o sensor TCS3472. Esta combinação gera quatro funções de ponderação distintas, que foram combinadas linearmente resultando em funções de ponderação próximas às da norma para as medições desejadas. Foram medidos transmitância luminosa e quocientes de atenuação visual para luzes semafóricas de 128 lentes de óculos de sol com o protótipo e com um padrão-ouro, o espectrofotômetro Cary 5000 da VARIAN. O método de Bland-Altman foi usado para análise de concordância entre ambos os métodos de medição. Para valores de transmitância luminosa, foram adotados 0,5 % e 6 % como valores a partir dos quais o valor absoluto do viés é significativo e a amplitude do intervalo de confiança, grande, respectivamente. Para valores dos quocientes de atenuação, 0,1 e 0,4; respectivamente. O viés não foi significativo para nenhuma das medições. O intervalo dos limites de concordância de 95% foi amplo para medição de transmitância luminosa e do quociente para luz azul e estreito para as demais, considerando-se os valores-limites previamente definidos para vieses e para limites de concordância. Assim, dentro da tolerância definida, medições com o protótipo e com o padrão-ouro são equivalentes para quociente de atenuação para as luzes vermelha, amarela e verde. Apesar de nem todas as medições do protótipo serem equivalentes às do padrão-ouro, os resultados apresentaram boa exatidão, com apenas 5 das 128 lentes classificadas erroneamente quanto à adequação para direção (2 por transmitância luminosa, 1 por luz vermelha e 2 por luz azul). O protótipo proporciona ao público uma forma de obter informações sobre seus próprios óculos de sol e sobre a importância do uso de óculos adequados durante a direção de veículos. / Category rating ranging from 0 to 4 determines how light or dark sunglasses lenses are. Category measurements and how much traffic signal colors are attenuated are required tests by brazilian standard ABNT NBR ISO 12312-1 and are known as transmittance tests. Brazilian standard also establishes requirements for sunglasses to be suitable for driving. However, people often do not have means to measure their own sunglasses. A standard transmittance test is laborious, time-consuming and it requires a spectrophotometer and a skilled technician. The goal of this study was to develop not only a single device capable to perform luminous and traffic light transmittance tests according to brazilian standard, but also an easy-to-use, quick, accurate and portable device, which runs the tests by itself in a way anyone can operate it without any training. Unlike the two systems previously developed in the Ophthalmic Instrumentation Laboratory (LIO) for transmittance tests, that one does not contain a computer, but a microcontroller. Also, it complies with current standard, which has been released in 2015, and previous systems are based on 2013 standard version. A microcontrolled prototype was developed and built using a white LED and TCS3472 sensor combination. This combination generates four different weighting functions that were linearly combined resulting in weighting functions similar to the standard ones for luminous and traffic light transmittances. Using our prototype and a gold standard (VARIAN Cary 5000 spectrophotometer), luminous transmittance and relative attenuation quotients for traffic lights were measured in 128 sunglasses lenses. Bland-Altman method was used to assess concordance between both measurement methods. The bias was insignificant for all measurement and the limits of agreement were broad for luminous transmittance and for relative attenuation quotient for blue light detection, and narrow for all the others. Thus, within the predefined tolerance, prototype measurements are equivalent to gold standard ones for relative attenuation quotients for red, yellow and green light detection. Despite not all prototype measurements being equivalent to gold standard ones, results were accurate; only 5 from 128 lenses were incorrectly classified as to suitability for driving (2 for luminous transmittance, 1 for red light quotient and 2 for blue light quotient). Our device aims to provide to general public a mean to obtain information about their own sunglasses and the importance to use suitable sunglasses while driving.
3

Dispositivo para medição e teste de transmitância luminosa e semafórica em óculos de sol de acordo com a norma brasileira - ABNT NBR ISO 12312-1:2015 / Device for luminous and traffic lights transmittance evaluation in sunglasses according Brazilian Standard - ABNT NBR ISO 12312-1:2015

Loureiro, Artur Duarte 06 November 2017 (has links)
A classificação por categoria de 0 a 4 para óculos de sol determina quão claras ou escuras são suas lentes. A norma brasileira, ABNT NBR ISO 12312-1, exige, entre outros requisitos, testes de transmitância da luz visível em óculos de sol (categoria), para que estes sejam classificados como adequados ou não para direção de automóveis. Medidas do grau de escurecimento das lentes de um par de óculos de sol e da atenuação luminosa das luzes de sinais semafóricos são testes propostos para este item da norma. Porém, o público, em geral, não possui meios de testar seus próprios óculos. Um teste padrão de transmitância é trabalhoso, demorado e requer um espectrofotômetro e um profissional treinado. O objetivo deste trabalho é desenvolver um dispositivo portátil capaz de realizar testes de transmitância luminosa e semafórica de acordo com a norma brasileira sendo rápido, preciso e intuitivo, realizando os testes de forma automática sem exigir do usuário qualquer treinamento prévio. Diferentemente dos dois sistemas anteriormente desenvolvidos no Laboratório de Instrumentação Oftálmica (LIO), para testes de transmitância, este dispositivo é embarcado e atende à norma atual lançada em 2015, que não estava em vigor na época em que os demais foram desenvolvidos. O desafio para se construir um sistema embarcado é a combinação de fontes luminosas e sensores necessária para se obter padrões espectrais similares aos da norma. Foi desenvolvido e construído um protótipo microcontrolado usando a combinação de um LED branco com o sensor TCS3472. Esta combinação gera quatro funções de ponderação distintas, que foram combinadas linearmente resultando em funções de ponderação próximas às da norma para as medições desejadas. Foram medidos transmitância luminosa e quocientes de atenuação visual para luzes semafóricas de 128 lentes de óculos de sol com o protótipo e com um padrão-ouro, o espectrofotômetro Cary 5000 da VARIAN. O método de Bland-Altman foi usado para análise de concordância entre ambos os métodos de medição. Para valores de transmitância luminosa, foram adotados 0,5 % e 6 % como valores a partir dos quais o valor absoluto do viés é significativo e a amplitude do intervalo de confiança, grande, respectivamente. Para valores dos quocientes de atenuação, 0,1 e 0,4; respectivamente. O viés não foi significativo para nenhuma das medições. O intervalo dos limites de concordância de 95% foi amplo para medição de transmitância luminosa e do quociente para luz azul e estreito para as demais, considerando-se os valores-limites previamente definidos para vieses e para limites de concordância. Assim, dentro da tolerância definida, medições com o protótipo e com o padrão-ouro são equivalentes para quociente de atenuação para as luzes vermelha, amarela e verde. Apesar de nem todas as medições do protótipo serem equivalentes às do padrão-ouro, os resultados apresentaram boa exatidão, com apenas 5 das 128 lentes classificadas erroneamente quanto à adequação para direção (2 por transmitância luminosa, 1 por luz vermelha e 2 por luz azul). O protótipo proporciona ao público uma forma de obter informações sobre seus próprios óculos de sol e sobre a importância do uso de óculos adequados durante a direção de veículos. / Category rating ranging from 0 to 4 determines how light or dark sunglasses lenses are. Category measurements and how much traffic signal colors are attenuated are required tests by brazilian standard ABNT NBR ISO 12312-1 and are known as transmittance tests. Brazilian standard also establishes requirements for sunglasses to be suitable for driving. However, people often do not have means to measure their own sunglasses. A standard transmittance test is laborious, time-consuming and it requires a spectrophotometer and a skilled technician. The goal of this study was to develop not only a single device capable to perform luminous and traffic light transmittance tests according to brazilian standard, but also an easy-to-use, quick, accurate and portable device, which runs the tests by itself in a way anyone can operate it without any training. Unlike the two systems previously developed in the Ophthalmic Instrumentation Laboratory (LIO) for transmittance tests, that one does not contain a computer, but a microcontroller. Also, it complies with current standard, which has been released in 2015, and previous systems are based on 2013 standard version. A microcontrolled prototype was developed and built using a white LED and TCS3472 sensor combination. This combination generates four different weighting functions that were linearly combined resulting in weighting functions similar to the standard ones for luminous and traffic light transmittances. Using our prototype and a gold standard (VARIAN Cary 5000 spectrophotometer), luminous transmittance and relative attenuation quotients for traffic lights were measured in 128 sunglasses lenses. Bland-Altman method was used to assess concordance between both measurement methods. The bias was insignificant for all measurement and the limits of agreement were broad for luminous transmittance and for relative attenuation quotient for blue light detection, and narrow for all the others. Thus, within the predefined tolerance, prototype measurements are equivalent to gold standard ones for relative attenuation quotients for red, yellow and green light detection. Despite not all prototype measurements being equivalent to gold standard ones, results were accurate; only 5 from 128 lenses were incorrectly classified as to suitability for driving (2 for luminous transmittance, 1 for red light quotient and 2 for blue light quotient). Our device aims to provide to general public a mean to obtain information about their own sunglasses and the importance to use suitable sunglasses while driving.
4

Sistema de análise de transmitâncias em lentes solares / Transmittance analysis system for solar lenses

Mello, Marcio Makiyama 10 April 2014 (has links)
Medidas de transmitância em óculos de sol fazem parte de alguns dos testes propostos pela norma NBR15111, porém, observou-se que não há no país um sistema preciso para medidas de transmitância que não seja com o uso de espectrofotômetros e pessoas qualificadas para utilizar o equipamento, aplicar as funções de ponderação e fornecer laudos técnicos sobre a lente testada. Assim, o trabalho propõe métodos que utilize componentes simples e resulte na construção de um equipamento que possa fornecer a informação sobre as transmitâncias dos filtros de óculos de sol de forma automática, de acordo com a NBR15111. Foi feita a espectrofotometria de 45 lentes de óculos de uso geral, e calculadas suas respectivas transmitâncias (luminosa, ultravioleta, semafórica), como amostras de comparação com as metodologias testadas. Os testes incluíram lâmpadas e LEDs como fontes de emissão para a região do espectro visível e lâmpadas fluorescentes para a região ultravioleta, além de sensores específicos para cada região espectral, e eletrônica de controle e aquisição dos sinais. Foram usadas ferramentas de análise estatística, como erro RMS, coeficiente de aderência (GFC) e análise de Bland-Altman. Aproximadamente 62% dos óculos testados foram reprovados para a direção no trânsito e nenhum foi reprovado para a proteção UV. Os métodos RMS e GFC apontaram combinações entre fonte e sensor que conseguem fazer a ponderação com os menores desvios-padrão das medidas espectrométricas. O sistema para teste UV mostrou melhoria significativa em relação aos desenvolvidos anteriormente, com um desvio padrão de 4,45 pontos percentuais e o sistema para testes na região visível utilizou o sensor TCS, no qual a regressão polinomial mostrou melhores resultados que as redes neurais artificiais, com os menores limites de concordância para as transmitâncias. Um número maior de amostras pode melhorar os métodos para que se obtenha uma aproximação ideal para todos os óculos de sol. Uma montagem com LEDs se apresenta como uma alternativa interessante quanto ao custo, tamanho e baixo consumo para medidores de transmitância portáteis. Desenvolveu-se um sistema com módulos para teste UV, Visível e Semafórico, para uso público no campus da USP de São Carlos, proporcionando conscientização e extensão dos estudos em relação aos óculos solares, contribuindo efetivamente com a população brasileira. / Transmittance measurements in sunglasses are a part of the standard tests proposed by NBR15111, however, it was observed that there is no accurate system for measuring transmittance different than using spectrophotometers and skilled practitioner to manage the equipment, apply the weighting functions and provide technical reports on the lens tested. Therefore, this study proposes methodologies using simple components and that can result a device that can provide information about sunglass filters automatically, according to NBR15111. Spectrophotometry was calculated in 45 lenses of sunglasses for general use, and their respective transmittance (visible, ultraviolet, traffic light), used as samples for testing the methodologies. The tests included lamps and LEDs as light sources for the visible region spectrum and fluorescent lamps for ultraviolet region, specific sensors for each spectral region, and electronic for control and signal acquisition. Statistical analysis tools were used, such as RMS error, goodness-of-fit coefficient (GFC) and the Bland - Altman analysis. Approximately 62% of the tested lenses failed in the test for signal light recognition and none has failed for UV protection. The RMS and GFC methods indicated combinations between source and sensor that calculated transmittance with the lowest standard deviations of the spectrometric measurements. The system for testing UV showed improvement compared to other previously equipment, with a standard deviation of 4.45 and the system for testing the visible region used the TCS sensor, in which the polynomial regression showed better results than artificial neural networks. A larger number of samples can improve the methods in order to obtain an optimal calibration that includes all sunglasses. LEDs seem to be a good alternative in terms of cost, size and low power consumption for portable transmittance meters. We developed a system with modules for testing UV, Visible and Traffic Light transmittance for public use on the USP São Carlos campus, providing awareness and extent of studies about the sunglasses, in order to contribute more effectively to the Brazilian population.
5

Avaliação da radiação UV na córnea humana em procedimentos oftalmológicos / Evaluation of UV radiation on human cornea in ophthalmic procedures

Lincoln, Victor Antonio Cacciacarro 10 August 2012 (has links)
A radiação ultravioleta pode tanto ser um benefício, como um malefício para o olho humano. Os benefícios são quando é utilizada em procedimentos oftalmológicos para a correção da visão, como nas cirurgias foto-refrativas - UVC - 193 nm; ou para, entre outros tratamentos, impedir a progressão de patologias, como é o caso do crosslinking do colágeno corneano, para ceratocones em estágios inicias que utiliza UVA - 370 nm. Os malefícios são os já amplamente conhecidos pela comunidade científica e populacional, sobre a incidência excessiva de radiação UV nos olhos, causando danos severos ao olho humano. Entretanto, a córnea tem uma proteção natural contra os raios UVA e UVB. Neste trabalho, estudou-se os dois procedimentos oftalmológicos citados a fim de investigar possíveis danos ao olho humano, como a perda da proteção natural da córnea pós cirurgia foto-refrativa, que retira lamelas da córnea; e a quantidade de radiação que adentra o olho humano, durante o crosslinking do colágeno corneano, que utiliza Riboflavina como sintetizador e bloqueador da radiação UVA. Um sistema portátil foi desenvolvido para avaliação da proteção UV e seus danos para o primeiro caso. O protótipo consiste de um sistema de duplo feixe e analisa a transmitância do tecido corneano na faixa de 300-400 nm, e apresenta um fator de correlação r2>0,98. As medidas com remoção de tecido indicaram a importância das camadas da córnea, e a remoção do estroma apresentou uma perda significativa da proteção natural UV, com aumento de 8,2-10,1 pontos percentuais. Já para o crosslinking, que utiliza a combinação riboflavina e UVA, com irradiância de 3 mw/\'CM POT.2\' por 30 minutos foi feito o monitoramento da transmitância UVA durante o tratamento. Foi realizado o protocolo do procedimento atual, ou seja, uma gota de Riboflavina 0,1%, 400mOsm, foi instilada na córnea desepitelizada, a cada 5 minutos (total de 12 gotas). A irradiação UV (365 ± 5 nm, 3 mW/\'CM POT.2\') foi realizada após 30 min de instalação por uma adicional de mais 30 min. A transmitância média da córnea desepitelizada sem Riboflavina foi de 61,6%; após a 1ª instilação de Riboflavina a transmitância foi de 44,9%; após a 6ª gota 22,4%; após a 7ª gota (início da irradiação), 19,5%; após a 8ª gota, 17,3%; após a 9ª, 15,8%; após a 10ª; 14,5%; após a 11ª; 13,5%; e após a 12ª instilação, 12,6%. A transmitância média em termos de energia durante os 30 min de irradiação apresentou uma variação de 0,590 até 0,380 mW/\'CM POT.2\', valores além do limite atualmente aceito para endotélio de córneas de coelhos, que apresenta um nível de segurança citotóxico de 0,36 mW/\'CM POT.2\'. / Ultraviolet radiation can either be a benefit as an harm to the human eye. The benefits are when used in ophthalmic procedures for vision correction, as in the photorefractive surgery - UVC - 193 nm; or to, among other treatments, preventing the progression of diseases, such as the corneal collagen crosslinking, for keratoconus in the early stages - that uses UVA - 370 nm. The harm effects are already widely known by the scientific community and general population, about excessive incidence of UV radiation in the eye, that can cause severe damage to the human eye. However, the cornea has a natural UVA and UVB protection. In this work, we studied the two ophthalmic procedures cited in order to investigate possible damage to the human eye, as the loss of cornea UV natural protection after photorefractive surgery, which removes corneal lamella; and the amount of radiation that penetrates the human eye during the corneal collagen crosslinking, that uses Riboflavin as a synthesizer and UVA radiation blocking. A portable system was developed to evaluate the UV protection and the UV damage for the first case. The prototype consists of a double beam system that analyzes the corneal tissue transmittance in the 300-400 nm range, and presents a correlation factor r2>0.98. Measurements with tissue removal showed the importance of each corneal layer, specially the stroma removal that shows a significant loss of natural UV protection, with an increase of 8.2 to 10.1 percentage points. As for the crosslinking, using riboflavin and UVA irradiance combination, with 3 mw/\'CM POT.2\' for 30 minutes, was performed a monitoring of UVA transmittance during treatment. Current procedure protocol was performed, i.e., one drop of riboflavin 0.1%, 400mOsm, was applied on the naked cornea, every 5 minutes (total of 12 drops). The UV irradiation (365 ± 5 nm, 3 mW/\'CM POT.2\') was performed after 30 min of instillation for an additional 30 min. The average transmittance of the desepithelized cornea without Riboflavin is 61.6%; after the 1st drop of Riboflavin, transmittance is 44.9%; after 6th drop 22.4%; after 7th drop (irradiation starts), 19.5%; after 8th drop; 17.3%; after 9th drop, 15.8%; after 10h drop, 14.5%; after 11th drop, 13.6%; after 12th drop, 12.6%. The average transmittance in terms of energy during the 30 min irradiation procedure fluctuated from 0.590 to 0.380 mW/\'CM POT.2\', beyond the currently accepted rabbit corneal endothelium safety limit for cytotoxic level of 0.360 mW/\'CM POT.2\'.
6

Avaliação da integridade superficial do polimetilmetacrilato (PMMA) no torneamento com ferramenta de diamante / Evaluation of the surface integrity of polymethymethacrylate (PMMA) in diamond turning tool

Granado, Renê Mendes 10 August 2006 (has links)
O torneamento com ferramenta de diamante é um processo de fabricação usado para a produção de componentes ópticos com alta precisão de forma e qualidade óptica final. O crescente uso de materiais poliméricos na industria, particularmente em equipamentos de precisão eletrônica e óptica tem exigido o estudo e entendimento de suas características e propriedades específicas. Esse trabalho avalia a integridade superficial do polimetilmetacrilato torneado com ferramenta de diamante, com relação à transmitância. Os parâmetros de usinagem objetivaram a obtenção de superfície gerada no modo dúctil. As rotações usadas foram 550 e 1000 rpm, a faixa do avanço variou de 5 a 20 µm/rev e a profundidade de usinagem de 4 e 10 µm. Duas ferramentas com geometrias diferentes foram usadas nos testes, com ângulos de saída de -5° e +5°, com raios de ponta de 1,143mm e 1,524 mm. A superfície final e morfologia dos cavacos foram avaliadas por microscopia eletrônica de varredura e a transmitância medida por espectofotometria. A integridade superficial foi claramente influenciada pelo ângulo de saída da ferramenta como observado na literatura. Devido a formação de cavacos no regime dúctil, a superfície final apresentou microtrincas em função do fluxo viscoelástico. A menor rugosidade obtida foi de 33,2 nm para a condição de corte de 10 µm/rev e 10 µm de profundidade de usinagem. Quando os resultados foram comparados as lentes injetadas, observou-se que o valor da transmitância são muito similares. / Single point diamond turning is a manufacturing process used to fabricate optical and precision components with high form accuracy and optical quality surface finish. The increase in the use of polymer materials in industry, particularly in electronic and optic precision devices, has demanded the study and understanding of its specific characteristics and properties. This work is addressed to the evaluation of the surface integrity of diamond turned polymethylmethacrilate regarding the trade off surface integrity versus transmitance. The cutting conditions were selected in order to work within the ductile mode material removal range. The spindle speed were 550 and 1000 rpm, feed rate ranging from 5 up to 20 micrometer/rev and the depth of cut ranging from 4 up to 10 micrometer. Two different tool geometries were used in the tests, a -5 \'DEGREES\' and +5 \'DEGREES\' rake angles with round nose radius tools of 1,143 mm and 1,524 mm. Surface finish and morphology of the chips was evaluated by scanning electron microscopy and transmitance measured by spectophometry technique. The surface integrity was clearly influenced by the cutting tool rake angle as observed in literature. Despite the formation of ductile chips the surface finished presented microcracks likely due the instability of the viscoelastic flow. The lower surface roughness obtained was 33,2 nm Ra for the cutting condition of 10 micrometer/rev and 10 micrometer depth of cut. When the results were compared with injected lenses, it was observed that the value of transmittance was very similar.
7

"Contribuição para o estudo da propagação da luz atráves do esmalte e da dentina humanos" / A Contribution for the Study of the Propagation of Light through the Human Enamel and Dentine

Steagall Junior, Washington 01 June 2005 (has links)
Este trabalho estuda a propagação da luz no esmalte e dentina humanos, através da transmitância direta e absorbância no intervalo de comprimento de onda de 200 a 3200nm, e através da transmitância total no intervalo de onda de 380 a 760nm. Foram utilizadas secções de 30 molares humanos íntegros, que foram seccionados nos sentidos VL (vestíbulo – Lingual), MD (mésio distal) e OC (ocluso cervical). As espessuras utilizadas foram de 0,5mm e 0,25mm. Foram agrupados 5 dentes para cada sentido para cada espessura. Esmalte e dentina estavam presentes de maneira simultânea na mesma amostra. A absorbância foi calculada, a partir dos espectros de transmitância direta, aplicando-se a Lei e Beer-Lambert. Os espectros de transmitância total foram obtidos no espectro visível, e comparados, em média, com os espectros de transmitância direta no mesmo intervalo, para obter a energia difusa das amostras. Os espectros UV (Ultravioleta), VIS (Visível) e IV (Infravermelho), foram tratados separadamente para cada tecido e espessura. No infravermelho foram identificados os picos de transmitância e absorbância para ambos os tecidos. Os valores de transmitância e absorbância para cada faixa espectral foram tratados pela ANOVA, e os grupos comparados pelo teste de intervalo de confiança (95%). Os resultados mostraram que, as propriedades ópticas do esmalte e dentina diferem no que diz respeito as 3 faixas espectrais testadas. Os resultados também mostram que as propriedades ópticas são dependentes da espessura e do sentido de seccionamento dos dentes. A pesar das diferenças apresentadas entre os espectros, as curvas espectrais mostraram um padrão semelhante para todas as amostras de dentina e de esmalte, independente da espessura. Este comportamento possibilitou a identificação de picos comuns nos espectros estudados. / This research studies the propagation of light in the human enamel and dentine, through direct transmittance and absorbance in the 200 to 3200nm wavelength interval, and through total transmittance in the 380 to 760nm wavelength interval. The study employed sections of 30 human integral molars, which were sectioned in the VL directions (vestibule – Lingual), MD (mesio distal), and OC (occlusion cervical). The thicknesses used were from 0.5mm to 0.25mm. Five teeth were grouped in each direction for each thickness. Enamel and dentine were simultaneously present in the same sample. Absorbance was calculated from the direct transmittance specters, applying the Beer-Lambert Law. Total transmittance specters were obtained in the visible specter, and compared, on average, with the Total transmittance specters in the same interval, to obtain the diffuse energy of the samples. UV (Ultraviolet), VIS (Visible), and IV (Infrared) specters, were treated separately for each tissue and thickness. In infrared, the transmittance and absorbance peaks were identified for both tissues. The transmittance and absorbance spectral range were treated by ANOVA, and the groups compared by the confidence interval test (95%). The results showed that the optical properties of the enamel and dentine differ with regard to the three tested spectral ranges. The results also showed that the optical properties are dependent on the thickness and the direction of the sectioning of the teeth. Despite the differences found between the specters, the special curves showed a similar pattern for all samples of dentine and enamel, independently of the thickness. This behavior allowed the identification of common peaks in the specters under study.
8

Influência da composição e cor de cerâmicas na transmissão de luz e no grau de conversão de cimentos resinosos de ativação dual / Effect of ceramic composition and shade in light transmission and degree of conversion of dual-cure resin cements

Mendonça, Luana Menezes de 14 September 2015 (has links)
O objetivo desta pesquisa foi avaliar a transmitância de diferentes tipos e cores de cerâmicas e seus efeitos no grau de conversão (GC) de dois tipos de cimentos resinosos com modo de polimerização dual. Foram confeccionadas 60 pastilhas com a cerâmica IPS e.max (Ivoclar Vivadent, Schaan, Liechtenstein) e divididas em 3 grupos: LT, MO e Z, com 20 pastilhas cada um. Nos grupos LT e MO, as pastilhas foram confeccionadas com a cerâmica de dissilicato de lítio de baixa translucidez (LT - low transluscency) e de média opacidade (MO - medium opacity), respectivamente. No grupo Z, as pastilhas foram confeccionadas em zircônia. Cada grupo foi subdividido em 5 subgrupos (n=4), de acordo com a cor da cerâmica: A2; A3,5; B2; C2; D3. No grupo LT, as pastilhas foram prensadas nas cores anteriormente citadas e, nos grupos MO e Z, as pastilhas foram, inicialmente, confeccionadas para simular infraestruturas e, posteriormente, receberem aplicação de cerâmica de revestimento IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein) nas mesmas cores. O espectrofotômetro UV 1800 Shimadzu foi utilizado para medir a transmitância de cada espécime de cerâmica (2,0 mm de espessura). Para medir o GC, espécimes dos cimentos resinosos Variolink II (Ivoclar Vivadent, Schaan, Liechtenstein) e Rely X U200 (3M ESPE, St. Paul, MN, USA), com espessura de 100 μm, foram fotopolimerizados sob os discos de cerâmica por 40 s. Espécimes dos cimentos fotoativados sem a interposição da cerâmica foram usados como grupo controle. A polimerização dos cimentos foi avaliada através da espectrometria no infravermelho com transformada de Fourier (FTIR) empregando o método de reflexão atenuada total (ATR) imediatamente após a fotopolimerização. Os resultados foram submetidos aos testes ANOVA a 1 critério e Teste de Tukey (α=5%). Os valores de transmitância foram inferiores a 1%, sendo que as do grupo LT apresentaram, em geral, os maiores valores de transmitância, seguidos dos grupos MO e Z. O GC do cimento Variolink II não sofreu influência da interposição da pastilha de cerâmica. Para o cimento Rely X U200, a interposição de alguns tipos/cores de cerâmica (LT A3,5; MO A2; MO A3,5 e Z A3,5) diminuíram o GC em relação ao grupo controle. Concluiu-se que os valores de transmitância e GC foram influenciados pelos tipos/cores de cerâmica. Entretanto, somente o grupo formado pela cerâmica de dissilicato de lítio LT, usando o Rely X U200, apresentou correlação negativa entre transmitância e GC. / The aim of the present study was to evaluate the transmittance of different ceramic types and shades and their effects on the degree of conversion (DC) of two dual-cure resin cements. Sixty discs were fabricated with IPS e.max ceramic (Ivoclar Vivadent, Schaan, Liechtenstein) and divided into three groups (n= 20 in each group): LT, MO and Z. For LT and MO groups discs were fabricated with low translucency (LT) and medium opacity (MO) lithium disilicate ceramic, respectively. Discs from Z group were manufactured of zirconia. Each group was divided into five subgroups (n = 4), according to the ceramic shade: A2; A3,5; B2; C2; D3. In the LT group, specimens were heat-pressed in shades cited above and in the MO and Z groups, the discs were initially fabricated as core materials and then veneered with veneer ceramic (IPS e.max Ceram, Ivoclar Vivadent, Schaan, Liechtenstein) in the same shades. A spectrophotometer UV-1800 Shimadzu was used to determine the transmittance percentage of each ceramic specimen (2.0-mm-thick). For DC measurements, the resin cements (Variolink II - Ivoclar Vivadent, Schaan, Liechtenstein and Rely X U200 - 3M ESPE, St. Paul, MN, USA) specimens (thickness: 100 μm) were photocured under the ceramic discs (2.0-mm-thick) for 40 s. Specimens photocured without the ceramics discs were used as control group. ATR/FTIR spectrometry was used to evaluated the extent of polymerization for all cement specimens immediately after photocuring. The results were submitted to one-way ANOVA and Tukey test (α=5%). The transmittance percentage was less than 1% and the LT group had the highest transmittance values, followed by MO and Z groups. The %DC of Variolink II cement was not influenced by the ceramic disc interposition. For Rely X U200 cement, the interposition of some ceramics types/shades (LT A3,5, MO A2, MO A3,5 and Z A3,5) significantly decreased the %DC compared to control group. It was concluded that the transmittance values and %DC were influenced by the ceramics types/shades. However, only the LT group, using the Rely X U200, showed a negative correlation between transmittance and %DC.
9

Avaliação da integridade superficial do polimetilmetacrilato (PMMA) no torneamento com ferramenta de diamante / Evaluation of the surface integrity of polymethymethacrylate (PMMA) in diamond turning tool

Renê Mendes Granado 10 August 2006 (has links)
O torneamento com ferramenta de diamante é um processo de fabricação usado para a produção de componentes ópticos com alta precisão de forma e qualidade óptica final. O crescente uso de materiais poliméricos na industria, particularmente em equipamentos de precisão eletrônica e óptica tem exigido o estudo e entendimento de suas características e propriedades específicas. Esse trabalho avalia a integridade superficial do polimetilmetacrilato torneado com ferramenta de diamante, com relação à transmitância. Os parâmetros de usinagem objetivaram a obtenção de superfície gerada no modo dúctil. As rotações usadas foram 550 e 1000 rpm, a faixa do avanço variou de 5 a 20 µm/rev e a profundidade de usinagem de 4 e 10 µm. Duas ferramentas com geometrias diferentes foram usadas nos testes, com ângulos de saída de -5° e +5°, com raios de ponta de 1,143mm e 1,524 mm. A superfície final e morfologia dos cavacos foram avaliadas por microscopia eletrônica de varredura e a transmitância medida por espectofotometria. A integridade superficial foi claramente influenciada pelo ângulo de saída da ferramenta como observado na literatura. Devido a formação de cavacos no regime dúctil, a superfície final apresentou microtrincas em função do fluxo viscoelástico. A menor rugosidade obtida foi de 33,2 nm para a condição de corte de 10 µm/rev e 10 µm de profundidade de usinagem. Quando os resultados foram comparados as lentes injetadas, observou-se que o valor da transmitância são muito similares. / Single point diamond turning is a manufacturing process used to fabricate optical and precision components with high form accuracy and optical quality surface finish. The increase in the use of polymer materials in industry, particularly in electronic and optic precision devices, has demanded the study and understanding of its specific characteristics and properties. This work is addressed to the evaluation of the surface integrity of diamond turned polymethylmethacrilate regarding the trade off surface integrity versus transmitance. The cutting conditions were selected in order to work within the ductile mode material removal range. The spindle speed were 550 and 1000 rpm, feed rate ranging from 5 up to 20 micrometer/rev and the depth of cut ranging from 4 up to 10 micrometer. Two different tool geometries were used in the tests, a -5 \'DEGREES\' and +5 \'DEGREES\' rake angles with round nose radius tools of 1,143 mm and 1,524 mm. Surface finish and morphology of the chips was evaluated by scanning electron microscopy and transmitance measured by spectophometry technique. The surface integrity was clearly influenced by the cutting tool rake angle as observed in literature. Despite the formation of ductile chips the surface finished presented microcracks likely due the instability of the viscoelastic flow. The lower surface roughness obtained was 33,2 nm Ra for the cutting condition of 10 micrometer/rev and 10 micrometer depth of cut. When the results were compared with injected lenses, it was observed that the value of transmittance was very similar.
10

Avaliação da radiação UV na córnea humana em procedimentos oftalmológicos / Evaluation of UV radiation on human cornea in ophthalmic procedures

Victor Antonio Cacciacarro Lincoln 10 August 2012 (has links)
A radiação ultravioleta pode tanto ser um benefício, como um malefício para o olho humano. Os benefícios são quando é utilizada em procedimentos oftalmológicos para a correção da visão, como nas cirurgias foto-refrativas - UVC - 193 nm; ou para, entre outros tratamentos, impedir a progressão de patologias, como é o caso do crosslinking do colágeno corneano, para ceratocones em estágios inicias que utiliza UVA - 370 nm. Os malefícios são os já amplamente conhecidos pela comunidade científica e populacional, sobre a incidência excessiva de radiação UV nos olhos, causando danos severos ao olho humano. Entretanto, a córnea tem uma proteção natural contra os raios UVA e UVB. Neste trabalho, estudou-se os dois procedimentos oftalmológicos citados a fim de investigar possíveis danos ao olho humano, como a perda da proteção natural da córnea pós cirurgia foto-refrativa, que retira lamelas da córnea; e a quantidade de radiação que adentra o olho humano, durante o crosslinking do colágeno corneano, que utiliza Riboflavina como sintetizador e bloqueador da radiação UVA. Um sistema portátil foi desenvolvido para avaliação da proteção UV e seus danos para o primeiro caso. O protótipo consiste de um sistema de duplo feixe e analisa a transmitância do tecido corneano na faixa de 300-400 nm, e apresenta um fator de correlação r2>0,98. As medidas com remoção de tecido indicaram a importância das camadas da córnea, e a remoção do estroma apresentou uma perda significativa da proteção natural UV, com aumento de 8,2-10,1 pontos percentuais. Já para o crosslinking, que utiliza a combinação riboflavina e UVA, com irradiância de 3 mw/\'CM POT.2\' por 30 minutos foi feito o monitoramento da transmitância UVA durante o tratamento. Foi realizado o protocolo do procedimento atual, ou seja, uma gota de Riboflavina 0,1%, 400mOsm, foi instilada na córnea desepitelizada, a cada 5 minutos (total de 12 gotas). A irradiação UV (365 ± 5 nm, 3 mW/\'CM POT.2\') foi realizada após 30 min de instalação por uma adicional de mais 30 min. A transmitância média da córnea desepitelizada sem Riboflavina foi de 61,6%; após a 1ª instilação de Riboflavina a transmitância foi de 44,9%; após a 6ª gota 22,4%; após a 7ª gota (início da irradiação), 19,5%; após a 8ª gota, 17,3%; após a 9ª, 15,8%; após a 10ª; 14,5%; após a 11ª; 13,5%; e após a 12ª instilação, 12,6%. A transmitância média em termos de energia durante os 30 min de irradiação apresentou uma variação de 0,590 até 0,380 mW/\'CM POT.2\', valores além do limite atualmente aceito para endotélio de córneas de coelhos, que apresenta um nível de segurança citotóxico de 0,36 mW/\'CM POT.2\'. / Ultraviolet radiation can either be a benefit as an harm to the human eye. The benefits are when used in ophthalmic procedures for vision correction, as in the photorefractive surgery - UVC - 193 nm; or to, among other treatments, preventing the progression of diseases, such as the corneal collagen crosslinking, for keratoconus in the early stages - that uses UVA - 370 nm. The harm effects are already widely known by the scientific community and general population, about excessive incidence of UV radiation in the eye, that can cause severe damage to the human eye. However, the cornea has a natural UVA and UVB protection. In this work, we studied the two ophthalmic procedures cited in order to investigate possible damage to the human eye, as the loss of cornea UV natural protection after photorefractive surgery, which removes corneal lamella; and the amount of radiation that penetrates the human eye during the corneal collagen crosslinking, that uses Riboflavin as a synthesizer and UVA radiation blocking. A portable system was developed to evaluate the UV protection and the UV damage for the first case. The prototype consists of a double beam system that analyzes the corneal tissue transmittance in the 300-400 nm range, and presents a correlation factor r2>0.98. Measurements with tissue removal showed the importance of each corneal layer, specially the stroma removal that shows a significant loss of natural UV protection, with an increase of 8.2 to 10.1 percentage points. As for the crosslinking, using riboflavin and UVA irradiance combination, with 3 mw/\'CM POT.2\' for 30 minutes, was performed a monitoring of UVA transmittance during treatment. Current procedure protocol was performed, i.e., one drop of riboflavin 0.1%, 400mOsm, was applied on the naked cornea, every 5 minutes (total of 12 drops). The UV irradiation (365 ± 5 nm, 3 mW/\'CM POT.2\') was performed after 30 min of instillation for an additional 30 min. The average transmittance of the desepithelized cornea without Riboflavin is 61.6%; after the 1st drop of Riboflavin, transmittance is 44.9%; after 6th drop 22.4%; after 7th drop (irradiation starts), 19.5%; after 8th drop; 17.3%; after 9th drop, 15.8%; after 10h drop, 14.5%; after 11th drop, 13.6%; after 12th drop, 12.6%. The average transmittance in terms of energy during the 30 min irradiation procedure fluctuated from 0.590 to 0.380 mW/\'CM POT.2\', beyond the currently accepted rabbit corneal endothelium safety limit for cytotoxic level of 0.360 mW/\'CM POT.2\'.

Page generated in 0.4479 seconds