• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de sistemas eletroquímicos acoplados a RMN de baixo e alto campo para análises in situ / Development of the electrochemical systms coupled to the low and high-field NMR for in situ analysis

Nunes, Luiza Maria da Silva 19 April 2012 (has links)
Neste trabalho é descrito o desenvolvimento de sistemas eletroquímicos (EQ) acoplados com a RMN de baixo e alto campo para análises in situ. Para a análise EQ-RMN de baixo campo, foi construído um sistema eletroquímico para ser utilizado tanto em um espectrômetro RMN-DT (B0= 0,23 T) quanto em um sensor unilateral (B0= 0,4 T). A platina foi utilizada como eletrodo de trabalho e contraeletrodo e um fio de prata como eletrodo de referência. A reação de eletrodeposição do cobre foi monitorada por meio do valor do tempo de relaxação transversal (T2), adquirido através da sequência de CPMG, em intervalos de 10 minutos durante a eletrólise, a potencial constante, no tempo de 3 horas. Ambas as análises, EQ-RMNDT e EQ-RMN Unilateral, apresentaram bom desempenho analítico. No entanto, foi observado que a análise de EQ-RMN Unilateral permitiu o monitoramento da reação eletroquímica com um volume detectável de amostra muito menor, em torno de 300 uL, do aquele para a RMN-DT (2,8 mL). O efeito do campo magnético (B0= 0,4 T) sobre o processo eletrolítico foi avaliado pela técnica de microscopia eletrônica de varredura (SEM). A análise SEM mostrou que o eletrodepósito de cobre obtido sob o efeito do campo apresenta uma morfologia rugosa. Para a análise in situ de EQRMN de alto campo, o sistema eletroquímico foi desenvolvido em um tubo de RMN de 10 mm de diâmetro, para ser utilizado em um espectrômetro de 9,4 T. A fibra de carbono foi o material mais adequado para ser utilizado como eletrodo de trabalho. A sequência de Precessão Livre no Estado Estacionário (SSFP, Steady State Free Precession), que não tem dependência do tempo de relaxação longitudinal T1, e permite a aquisição de centenas de espectros por segundo, foi utilizada para monitorar a eletrólise do 9-cloroantraceno por RMN de 13C. A célula EQ-RMN de alto campo construída possibilitou a aquisição de espectros de RMN de 1H e SSFP de 13C durante a eletrólise do 9-cloroantraceno. O Método da Diagonalizacão Filtrada (FDM, Filter Diagonalization Method) foi utilizado para processar sinais no domínio do tempo de SSFP 13C, para resolver os problemas de anomalia de fase e melhorar a resolução espectral. Os sistemas eletroquímicos construídos apresentaram um bom desempenho analítico para o interfaceamento com a RMN, e as metodologias empregadas propiciaram o monitoramento em tempo real de uma reação eletroquímica. / In this work it is described the development of electrochemical (EC) systems coupled to the Low and High-field NMR for in situ analysis. By low-field NMR-EC analysis, it was constructed an electrochemical system to be utilized both TD-NMR spectrometer (B0= 0.23 T) and unilateral sensor (B0= 0.4 T). Platinum was used as working electrode and counter electrode and a silver wire as reference electrode. The copper electrodeposition reaction was monitored by Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence. The measurements of the transverse relaxation time (T2) were collected in the interval of 10 minutes during electrolysis, constant potential, in 3 hours time. Both in situ analyses, TD-NMR-EC and Unilateral NMR-EC, demonstrated good analytical performance. However, the Unilateral NMR-EC allowed the monitoring copper concentration during electrolysis using detectable volume much smaller, approximately 300 uL, than TD-NMR (2.8 mL). The magnetic field effect (B0= 0.4 T) on electrolytic process was available by scanning electron microscopy (SEM) technique. The SEM analysis showed copper electrodeposits obtained on the field effect observes a rough morphology. For the in situ high-field NMR-EC analysis, the electrochemical system was developed in a tube NMR of 10 mm diameter to be utilized 9.4 T spectrometer. Carbon fiber was the most appropriated material to be used as working electrode. The Steady-state free precession (SSFP) sequence that has no dependence on the longitudinal relaxation time T1, allows it to acquire up to hundreds of spectra per T1 value, it was utilized to monitor the electrolysis of 9-chlroanthracene for 13C NMR. The high-field NMR-EC cell constructed allowed the acquisition of the 1H NMR and 13C SSFP spectra during the electrolysis of 9-chlroanthracene. The Filter Diagonalization Method (FDM) was used to process signals in the time domain of 13C SSFP, to solve problems of phase anomalies and improve the spectra resolution. The electrochemical systems constructed showed good analytical performance for coupling with NMR and the methodologies employed provided of the monitoring in real time of the electrochemical reaction.
2

Desenvolvimento de sistemas eletroquímicos acoplados a RMN de baixo e alto campo para análises in situ / Development of the electrochemical systms coupled to the low and high-field NMR for in situ analysis

Luiza Maria da Silva Nunes 19 April 2012 (has links)
Neste trabalho é descrito o desenvolvimento de sistemas eletroquímicos (EQ) acoplados com a RMN de baixo e alto campo para análises in situ. Para a análise EQ-RMN de baixo campo, foi construído um sistema eletroquímico para ser utilizado tanto em um espectrômetro RMN-DT (B0= 0,23 T) quanto em um sensor unilateral (B0= 0,4 T). A platina foi utilizada como eletrodo de trabalho e contraeletrodo e um fio de prata como eletrodo de referência. A reação de eletrodeposição do cobre foi monitorada por meio do valor do tempo de relaxação transversal (T2), adquirido através da sequência de CPMG, em intervalos de 10 minutos durante a eletrólise, a potencial constante, no tempo de 3 horas. Ambas as análises, EQ-RMNDT e EQ-RMN Unilateral, apresentaram bom desempenho analítico. No entanto, foi observado que a análise de EQ-RMN Unilateral permitiu o monitoramento da reação eletroquímica com um volume detectável de amostra muito menor, em torno de 300 uL, do aquele para a RMN-DT (2,8 mL). O efeito do campo magnético (B0= 0,4 T) sobre o processo eletrolítico foi avaliado pela técnica de microscopia eletrônica de varredura (SEM). A análise SEM mostrou que o eletrodepósito de cobre obtido sob o efeito do campo apresenta uma morfologia rugosa. Para a análise in situ de EQRMN de alto campo, o sistema eletroquímico foi desenvolvido em um tubo de RMN de 10 mm de diâmetro, para ser utilizado em um espectrômetro de 9,4 T. A fibra de carbono foi o material mais adequado para ser utilizado como eletrodo de trabalho. A sequência de Precessão Livre no Estado Estacionário (SSFP, Steady State Free Precession), que não tem dependência do tempo de relaxação longitudinal T1, e permite a aquisição de centenas de espectros por segundo, foi utilizada para monitorar a eletrólise do 9-cloroantraceno por RMN de 13C. A célula EQ-RMN de alto campo construída possibilitou a aquisição de espectros de RMN de 1H e SSFP de 13C durante a eletrólise do 9-cloroantraceno. O Método da Diagonalizacão Filtrada (FDM, Filter Diagonalization Method) foi utilizado para processar sinais no domínio do tempo de SSFP 13C, para resolver os problemas de anomalia de fase e melhorar a resolução espectral. Os sistemas eletroquímicos construídos apresentaram um bom desempenho analítico para o interfaceamento com a RMN, e as metodologias empregadas propiciaram o monitoramento em tempo real de uma reação eletroquímica. / In this work it is described the development of electrochemical (EC) systems coupled to the Low and High-field NMR for in situ analysis. By low-field NMR-EC analysis, it was constructed an electrochemical system to be utilized both TD-NMR spectrometer (B0= 0.23 T) and unilateral sensor (B0= 0.4 T). Platinum was used as working electrode and counter electrode and a silver wire as reference electrode. The copper electrodeposition reaction was monitored by Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence. The measurements of the transverse relaxation time (T2) were collected in the interval of 10 minutes during electrolysis, constant potential, in 3 hours time. Both in situ analyses, TD-NMR-EC and Unilateral NMR-EC, demonstrated good analytical performance. However, the Unilateral NMR-EC allowed the monitoring copper concentration during electrolysis using detectable volume much smaller, approximately 300 uL, than TD-NMR (2.8 mL). The magnetic field effect (B0= 0.4 T) on electrolytic process was available by scanning electron microscopy (SEM) technique. The SEM analysis showed copper electrodeposits obtained on the field effect observes a rough morphology. For the in situ high-field NMR-EC analysis, the electrochemical system was developed in a tube NMR of 10 mm diameter to be utilized 9.4 T spectrometer. Carbon fiber was the most appropriated material to be used as working electrode. The Steady-state free precession (SSFP) sequence that has no dependence on the longitudinal relaxation time T1, allows it to acquire up to hundreds of spectra per T1 value, it was utilized to monitor the electrolysis of 9-chlroanthracene for 13C NMR. The high-field NMR-EC cell constructed allowed the acquisition of the 1H NMR and 13C SSFP spectra during the electrolysis of 9-chlroanthracene. The Filter Diagonalization Method (FDM) was used to process signals in the time domain of 13C SSFP, to solve problems of phase anomalies and improve the spectra resolution. The electrochemical systems constructed showed good analytical performance for coupling with NMR and the methodologies employed provided of the monitoring in real time of the electrochemical reaction.
3

Determinação in situ de fósforo, nitrato e amônio em solo. / Phosphorus, nitrate and ammonium determination in soil in situ.

Menezes, Eveline de Abreu 28 July 2006 (has links)
Made available in DSpace on 2016-06-02T20:36:09Z (GMT). No. of bitstreams: 1 1227.pdf: 2236922 bytes, checksum: 9f36ad88abbf6d0cf1c979e5d9c2ddd6 (MD5) Previous issue date: 2006-07-28 / Universidade Federal de Sao Carlos / The cultures platforms of productivity need to be optimized, owing to provide foods to an enhanced world population. A control of the soil fertility is necessary, in order to be adequately productive without, however, have losses for excess of nutrients, which could cause serious environmental problems. Due to soils and cultures requirements, nitrogen and phosphorus fertilizations are the more important ones. In this work, selective chemical sensors to phosphorus (PO4 3-), nitrate (NO3 -) and ammonium (NH4 +), installed in polymeric probes and their associated instrumentation were evaluated. The evaluation was carried with the addition of 0.1 mol L-1 P-PO4 3- solution to the soil, data acquisition supplied by the probes, collects of soil samples in the region where the probes were installed and determination of evaluated nutrients by conventional laboratory techniques. The PO4 3- amounts were determined by spectrophotometry after the following extraction methodologies: Mehlich-1, Mehlich-3 and ionic exchange resin. The results were compared with the fitted potentials registered by the probes, and the best correlation was obtained with the method of the resin. For evaluation of the probes, constructed with selective sensors to NO3 - and NH4 +, NH4NO3 salt was added directly to the soil. Four probes had been installed; one of them was used as control. Surface and 20-cm soil depth, region where the sensors were located, were periodically collected. The amounts of NO3 - and NH4 + had been determined by spectrophotometry, by using procedure based on Berthlot reaction adapted to a flow system. The results, compared with the potentials provided by the sensors, presented similar changes profiles. Great alterations in the sensors potentials had not been observed after addition of nitrogen fertilization, due to the little percolation of nutrients in the soil profile. The results indicate good response of the sensors, and the potential applicability of these probes to assist the monitoring of soil nutrients, owing the establishment of rational processes in the fertilizers uses by the cultures. / Os patamares de produtividade das culturas necessitam ser otimizados, visando proporcionar alimentos a uma população mundial cada vez maior. Há necessidade de um controle da fertilidade dos solos, para que esses se mantenham adequadamente produtivos sem, no entanto haver perdas por excesso de nutrientes, o que pode vir a causar sérios problemas ambientais. As adubações nitrogenada e fosfatada se enquadram como as principais, em função das necessidades dos solos e culturas. Neste trabalho avaliou-se o emprego de sensores químicos seletivos a fósforo (PO4 3-), nitrato (NO3 -) e amônio (NH4 +) e sua instrumentação associada, instalados em sondas construídas em material polimérico. A avaliação foi realizada com a adição de solução 0,1 mol L-1 de P-PO4 3- ao solo, aquisição de dados fornecidos pelas sondas, por coletas de amostras de solo na região em que as sondas estavam instaladas e determinação dos teores desses nutrientes por técnicas convencionais em laboratório. Os teores de PO4 3- foram obtidos pelos seguintes métodos de extração: Mehlich-1, Mehlich-3 e resina de troca iônica e determinados por espectrofotometria. Comparou-se os resultados obtidos com os potenciais registrados pela sonda potenciométrica, que apresentou a melhor correlação com o método da resina. Para avaliação das sondas com sensores seletivos a NO3 - e NH4 +, sal de NH4NO3 foi adicionado diretamente ao solo. Foram instaladas quatro sondas, uma delas utilizada como testemunha, e periodicamente coletadas amostras de solo da superfície e à 20 cm de profundidade, região de colocação dos sensores. Os teores de NO3 - e NH4 + foram determinados por espectrofotometria, em procedimento baseado na reação de Berthlot adaptada a sistema em fluxo. Os resultados foram comparados aos potenciais obtidos pelos sensores, apresentando perfis similares de variação. Não foram verificadas grandes alterações nos potenciais dos sensores frente à adubação nitrogenada em decorrência da não percolação dos nutrientes no perfil do solo. Os resultados indicam boa resposta dos sensores e a potencial aplicabilidade destas sondas para o monitoramento de nutrientes no solo, auxiliando no estabelecimento de processos racionais no uso de fertilizantes nas culturas.
4

Análise em fluxo e análise in situ como estratégias de melhoramento da seqüência analítica de amostras agronômicas. / Flow analysis and in situ analysis as aproaches to the improvement of the agronomic samples analytical pathway.

Lemos, Sherlan Guimarães 06 April 2005 (has links)
Made available in DSpace on 2016-06-02T20:35:04Z (GMT). No. of bitstreams: 1 TeseSGL.pdf: 12991246 bytes, checksum: 9870a509426721e4fc141e8961533366 (MD5) Previous issue date: 2005-04-06 / Universidade Federal de Minas Gerais / The present work discusses the use of alternative approaches for the improvement of the agronomic sample analytical pathway. It was focused on the elimination of the sampling step, with the in situ soil analysis, or in the measurement step with the adoption of flow analysis procedures, with the development of two analytical systems. The first one was employed in the total nitrogen and its inorganic forms determination in plant and soil samples, based on the Berthelot reaction. The second flow analysis system was developed for phosphorous speciation in seeds and grains samples used in animal nutrition by means a cobalt metallic electrode. For the elimination of the sampling step in the process of soil analysis, an analytical probe prototype was developed (hardware probe, sensors and electronic instrumentation and software algorithms for acquirement, processing, conversion, storage and data transfer) by using PVC membrane ion-selective sensors suitable to be inserted into soils for obtaining in situ and real time information of nutrient assimilation on agricultural soils. Parameters as pH and availability of some nutrients (K+; N, as NO3 - and NH4 +; Ca2+ and P, as H2PO4 -/ HPO4 2-) were evaluated in this stage. Although more systematic studies are needed, the results showed good responses of the studied sensors, and the great applicability of the developed instrumentation in the fertility irrigation monitoring, helping to establish rational processes in agricultural systems. / O presente trabalho discute o emprego de estratégias alternativas no melhoramento da seqüência analítica de amostras de interesse agronômico. Para tanto, procurouse atuar na eliminação da etapa de amostragem, com a análise in situ de solos, ou na etapa de medida, com a adoção de métodos de análises em fluxo, onde foram desenvolvidos dois sistemas de análise. O primeiro foi empregado na determinação de nitrogênio total e suas formas inorgânicas em amostras de plantas e solos, baseado na reação de Berthelot. O segundo sistema de análise em fluxo foi desenvolvido para a especiação de fósforo em amostras de sementes e grãos utilizados em nutrição animal utilizando um eletrodo metálico de cobalto. Para a eliminação da etapa de amostragem no processo de análise de solos, foi desenvolvido um protótipo de sonda analítica (hardware sonda, sensor e instrumentação eletrônica e softwares algoritmos para aquisição, processamento, conversão, armazenamento e transferência de dados) utilizando sensores íon-seletivos de membrana polimérica à base de PVC suscetíveis à inserção em solos para obter informações in situ e em tempo real de processos de assimilação de nutrientes. Foram avaliados parâmetros de interesse na caracterização de solos agrícolas, tais como: pH e disponibilidade de alguns nutrientes (K+; N, como NO3 - e NH4 +; Ca2+ e P, como H2PO4 -/ HPO4 2-). Apesar de ainda serem necessários maiores estudos sistemáticos, os resultados indicam boa resposta dos sensores e a grande aplicabilidade deste instrumental no monitoramento da fertirrigação, auxiliando o estabelecimento dos processos racionais de gestão da agricultura.
5

Avaliação microestrutural e mecânica de peças de Aço Maraging 300 fabricadas por manufatura aditiva usando fusão seletiva a laser e submetidas a tratamentos térmicos / Microstructural and mechanical evaluation of maraging 300 steel parts manufactured by additive manufacturing using selective laser fusion and subjected to thermal treatments

Conde, Fábio Faria 07 May 2019 (has links)
O aço maraging é conhecido pela sua alta resistência mecânica proveniente da formação de precipitados intermetálicos como Ni3Ti e Fe2Mo durante o envelhecimento, porém com subsequente perda de tenacidade à fratura. Existe uma vasta literatura sobre este tipo de aço, o qual é submetido a diversos tratamentos térmicos. Normalmente dois tratamentos térmicos são aplicados: uma homogeneização inicial para solubilização dos precipitados, sendo a recomendação geral 820 °C/1 h, e posteriormente o tratamento de envelhecimento, variando a temperatura de 455 °C a 510 °C e o tempo de 3 a 12 h. No entanto, pode haver variações no tratamento, como aquecimento após homogeneização numa faixa de temperatura intercrítica ou abaixo da Ac1 visando a reversão da martensita em austenita e o refino de grão. Até o presente momento, não está bem definida a influência da temperatura/tempo em tratamentos de temperaturas inter ou subcríticas que visam o refinamento da estrutura e o aumento da austenita retida/reversa. A literatura mostra tratamentos na liga maraging 300 por meio de estudos mais antigos, da década de 70 e 80, utilizando aquecimentos curtos e cíclicos para reversão e estabilização da austenita reversa. Estudos mais recentes de outras ligas utilizaram tratamentos isotérmicos para difusão e reversão da martensita em austenita. Nesta proposta serão pesquisadas as duas rotas de tratamento, cíclica e isotérmica, para avaliar a reversão martensita-austenita. Os tratamentos cíclicos foram caracterizados por EBSD, MEV e difração de raio-X ex-situ. Os tratamentos isotérmicos foram caracterizados por EBSD e difração de raio-X de fonte sincrotron in-situ, ou seja, medida em tempo real durante o tratamento. Ambas as condições foram avaliadas mecanicamente por meio de ensaios de flexão de 3 pontos. / Maraging steel is known for its high mechanical strength resulting from the formation of intermetallic precipitates such as Ni3Ti and Fe2Mo during aging heat treatment, with subsequent loss of fracture toughness. There is a vast literature on this type of steel, which is subjected to various thermal treatments. Normally two heat treatments are applied: an initial homogenization for solubilization of the precipitates, the general recommendation being 820 ° C/1 h, and later the aging treatment, varying temperature from 455 ° C to 510 ° C and time of treatment from 3 to 12 hours. However, there may be applied other heat treatments, such as heating after homogenization in an intercritical temperature range or below Ac1 for the reversion of martensite-to-austenite and grain refinement. To date, the influence of temperature and time on inter- or subcritical temperature treatments aiming at grain refinement and martensite-to-austenite reversion is not well defined. The literature shows treatments in the maraging 300 alloy, from the 70s and 80s, using short and cyclic heat treatment for reversion and stabilization of austenite. Recent studies of other alloys have used isothermal treatments for diffusion and martensite-to-austenite revresion. In this study, two heat treatment routes, cyclical and isothermal, were investigated to evaluate the martensite-to-austenite reversion. Cyclic treatments were characterized by EBSD, SEM and ex-situ X-ray diffraction. The isothermal treatments were characterized by EBSD and X-ray diffraction of synchrotron source in-situ, that is, measured in real time during the treatment. Both conditions were mechanically evaluated by 3-point-bending tests.
6

Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and waste

Galhardo, Cristiane Xavier 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.
7

Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and waste

Cristiane Xavier Galhardo 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.

Page generated in 0.0873 seconds