• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 16
  • 15
  • 14
  • 12
  • 12
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Monitoramento automático de pH, níquel e cloretos em banhos de níquel tipo watts utilizando um sistema SIA

Edson da Silva, José January 2002 (has links)
Made available in DSpace on 2014-06-12T23:00:54Z (GMT). No. of bitstreams: 2 arquivo9164_1.pdf: 595241 bytes, checksum: a2100ae56e3235cdf2ee1bff35ecf347 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2002 / A necessidade de se realizar análises multiparamétricas, associadas a uma grande velocidade analítica para se tomar decisões rápidas, conduz ao desenvolvimento de sistemas automáticos de monitoramento on-line em muitos processos industriais. A galvanoplastia industrial é um procedimento bastante utilizado para evitar o desgaste de peças metálicas. Para que um processo de eletrodeposição seja bem sucedido, é necessário o controle constante da composição dos banhos eletrolíticos. Com este objetivo, neste trabalho foram propostos o desenvolvimento e a aplicação de um sistema SIA para determinação de pH, cloreto e níquel em banhos de níquel tipo Watts. Para a realização das medidas de pH e cloreto utilizou-se detecção potenciométrica com eletrodos seletivos tubulares, enquanto a determinação direta de níquel foi realizada por espectrofotometria direta em 660 nm. Para viabilizar a determinação de cloreto, recorreu-se à diálise da amostra em linha com membrana de acetato de celulose para diluição e separação da matriz. O sistema foi otimizado, empregando-se a técnica de planejamentos fatoriais onde foram avaliados a composição química da solução transportadora (tampão fosfato) e os parâmetros hidrodinâmicos. Foi obtida como condição ótima um volume de amostra de 500 μL, concentração do tampão de 0,025 mol L-1, pH 6,3 e vazões dos fluidos nas etapas de diálise e de bombeamento de 2,22 e 9,10 mL min-1, respectivamente. Nessas condições obteve-se linearidade de 1 a 5; 0,1-1,6 mol L-1 e 0,1-1,0 mol L-1 para pH, níquel e cloreto, respectivamente. O sistema SIA apresentou uma frequência analítica de 45 amostras h-1, com erros relativamente baixos (menores que 5 %) quando aplicado à análise de banhos de níquel tipo Watts
2

Emprego da análise por injeção sequencial (SIA) e de métodos estatísticos para a otimização de processos oxidativos avançados visando o tratamento de amostras da indústria de tintas / Application of Sequential Injection Analysis (SIA) and Statistical Methods for the Optimization of Advanced Oxidative Processes Aiming the Treatment of Coatings Industry Samples

Santos, Allan Cezar Vieira dos 30 July 2010 (has links)
Esta Tese descreve o emprego da Análise por Injeção Sequencial (SIA) e de métodos estatísticos visando a otimização do tratamento de amostras da indústria de tintas através de Processos Oxidativos Avançados (POA\'s), mais especificamente através das reações de Fenton e foto-Fenton. Estudos foram realizados com o composto modelo vermelho de alizarina S para a otimização de parâmetros da reação de Fenton e o com sal tetrassódico de ácido 3,4′,4″,4″′-tetrassulfônico de ftalocianina de cobre para a otimização de parâmetros da reação de foto-Fenton em um foto-reator desenvolvido em laboratório. Nas condições obtidas com SIA, foi observada a degradação de 99,7% de alizarina e de 97% da ftalocianina de cobre. Uma amostra de efluente da indústria de tintas também foi considerada; para esta matriz, os resultados apontaram uma mineralização de 79% do efluente após a reação de foto-Fenton e de 45% após a reação de Fenton. / This Thesis describes the use of Sequential Injection Analysis (SIA) and statistical methods aiming the optimization of the treatment processes of coatings samples by Advanced Oxidative Processes (AOP\'s), specifically by Fenton and photo-Fenton reactions. Studies were performed with model compounds, alizarin red S for optimization of Fenton parameters and a copper phthalocyanine-3,4′,4″,4″′-tetrasulfonic acid tetrasodium salt dye for optimization of photo-Fenton parameters in a homemade photo reactor. At SIA established conditions, it was observed a degradation of 99.7% of alizarin and 97% of the phthalocyanine dye. A sample of wastewater from the coatings industry was also considered; for this matrix, results showed a sample mineralization of 79% after photo-Fenton and 45% after Fenton reactions.
3

Desenvolvimento e avaliação de métodos de extração e separação cromatográfica em colunas monolíticas e superficialmente porosas para determinação de herbicidas triazínicos em solos e águas / Development and evaluation of extraction and chromatographic methods in monolithic and core-shell columns for determination of triazine herbicides in soils and waters

Urio, Ricardo De Prá 10 December 2015 (has links)
O uso de pesticidas levou ao aumento da produtividade e qualidade dos produtos agrícolas, porém o seu uso acarreta na intoxicação dos seres vivos pela ingestão gradativa de seus resíduos que contaminam o solo, a água e os alimentos. Dessa forma, há a necessidade do monitoramento constante de suas concentrações nos compartimentos ambientais. Para isto, busca-se o desenvolvimento de métodos de extração e enriquecimento de forma rápida, com baixo custo, gerando um baixo volume de resíduos, contribuindo com a química verde. Dentre estes métodos destacam-se a extração por banho de ultrassom e a extração por ponto nuvem. Após o procedimento de extração, o extrato obtido pode ser analisado por técnicas de Cromatografia a Líquido de Alta Eficiência (HPLC) e a Cromatografia por Injeção Sequencial (SIC), empregando fases estacionárias modernas, tais como as monolíticas e as partículas superficialmente porosas. O emprego de SIC com coluna monolítica (C18, 50 x 4,6 mm) e empacotada com partículas superficialmente porosas (C18, 30 x 4,6 mm, tamanho de partícula 2,7 µm) foi estudado para separação de simazina (SIM) e atrazina (ATR), e seus metabólitos, desetilatrazina (DEA), desisopropilatrazina (DIA) e hidroxiatrazina (HAT). A separação foi obtida por eluição passo-a-passo, com fases móveis compostas de acetonitrila (ACN) e tampão Acetato de Amônio/Ácido acético (NH4Ac/HAc) 2,5 mM pH 4,2. A separação na coluna monolítica foi realizada com duas fases móveis: MP1= 15:85 (v v-1) ACN:NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc a uma vazão de 35 µL s-1. A separação na coluna com partículas superficialmente porosas foi efetivada com as fases móveis MP1= 13:87 (v v-1) ACN: NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc à vazão de 8 µL s-1. A extração por banho de ultrassom em solo fortificado com os herbicidas (100 e 1000 µg kg-1) resultou em recuperações entre 42 e 160%. A separação de DEA, DIA, HAT, SIM e ATR empregando HPLC foi obtida por um gradiente linear de 13 a 35% para a coluna monolítica e de 10 a 35% ACN na coluna com partículas superficialmente porosas, sendo a fase aquosa constituída por tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 15 min. A extração por banho de ultrassom das amostras de solo com presença de ATR, fortificadas com concentrações de 250 a 1000 µg kg-1, proporcionou recuperações entre 40 e 86%. A presença de ATR foi confirmada por espectrometria de massas. Foram realizados estudos de fortificação com ATR e SIM em amostras de água empregando a extração por ponto nuvem com o surfactante Triton-X114. A separação empregando HPLC foi obtida por um gradiente linear de 13 a 90% de ACN para a coluna monolítica e de 10 a 90% de ACN para a coluna empacotada, sempre em tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 16 min. Fortificações entre 1 e 50 µg L-1 resultaram em recuperações entre 65 e 132%. / The use of pesticides has led to increased productivity and quality of agricultural products, but its use brings the intoxication of living beings by the gradual intake of their residues that contaminate soil, water and food. Thus, there is the need for constant monitoring of their concentrations in environmental compartments. For this, there is a quest for development of fast extraction and enrichment methods, at low cost, generating a low volume of waste, contributing to green chemistry. These methods include the extraction assisted by ultrasound bath and the cloud point extraction. After the extraction, the extract obtained can be analyzed by techniques such as High Performance Liquid Chromatography (HPLC) and Sequential Injection Chromatography (SIC) employing modern stationary phases, such as monolithic and superficially porous particles. The use of SIC with either monolithic column (C18, 50 x 4.6 mm) or column packed with superficially porous particles (C18, 30 x 4.6 mm, 2.7 µM particle size) was studied for separating simazine (SIM) and atrazine (ATR), and metabolites, deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (HAT). Separation was obtained by stepwise elution, with a mobile phase consisting of acetonitrile (ACN) and 2.5 mM ammonium acetate / acetic acid (NH4Ac / HAc) pH 4.2 buffer. The separation was performed with two mobile phases: MP1 = 15:85 (v v -1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at a flow rate of 35 µL s-1. The separation in the column with superficially porous particles was carried out with the mobile phases MP1 = 13:87 (v v-1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at 8 µL s-1. The ultrasound bath extraction from a soil fortified with herbicides (100 and 1000 µg kg-1) resulted in recoveries between 42 and 160 %. Separation of DEA, DIA, HAT SIM and ATR was obtained by HPLC employing a linear gradient from 13 to 35% for the monolithic column and from 10 to 35% ACN in the column packed with superficially porous particles, with the aqueous phases consisting of 2.5 mM NH4Ac / HAc buffer pH 4.2. In both columns the flow rate was 1.5 mL min-1 and the analysis time was15 min. Ultrasonic extraction from a soil sample containing ATR, fortified with concentrations from 250 to 1000 µg kg-1, provided recoveries between 40 and 86%. The presence of ATR was confirmed by mass spectrometry. Fortification studies with ATR and SIM were carried out in water samples employing cloud point extraction using Triton-X114 surfactant. The separation was accomplished by HPLC using a linear gradient from 13 to 90 % of ACN for the monolithic column and from 10 to 90 % ACN for the packed column, always in 2.5 mM NH4Ac / HAc pH 4.2 buffer. In both columns the flow rate was 1.5 mL min -1 and the analysis time 16 min. Fortifications between 1 and 50 µg L-1 resulted in recoveries between 65 and 132%.
4

Desenvolvimento e avaliação de métodos de extração e separação cromatográfica em colunas monolíticas e superficialmente porosas para determinação de herbicidas triazínicos em solos e águas / Development and evaluation of extraction and chromatographic methods in monolithic and core-shell columns for determination of triazine herbicides in soils and waters

Ricardo De Prá Urio 10 December 2015 (has links)
O uso de pesticidas levou ao aumento da produtividade e qualidade dos produtos agrícolas, porém o seu uso acarreta na intoxicação dos seres vivos pela ingestão gradativa de seus resíduos que contaminam o solo, a água e os alimentos. Dessa forma, há a necessidade do monitoramento constante de suas concentrações nos compartimentos ambientais. Para isto, busca-se o desenvolvimento de métodos de extração e enriquecimento de forma rápida, com baixo custo, gerando um baixo volume de resíduos, contribuindo com a química verde. Dentre estes métodos destacam-se a extração por banho de ultrassom e a extração por ponto nuvem. Após o procedimento de extração, o extrato obtido pode ser analisado por técnicas de Cromatografia a Líquido de Alta Eficiência (HPLC) e a Cromatografia por Injeção Sequencial (SIC), empregando fases estacionárias modernas, tais como as monolíticas e as partículas superficialmente porosas. O emprego de SIC com coluna monolítica (C18, 50 x 4,6 mm) e empacotada com partículas superficialmente porosas (C18, 30 x 4,6 mm, tamanho de partícula 2,7 µm) foi estudado para separação de simazina (SIM) e atrazina (ATR), e seus metabólitos, desetilatrazina (DEA), desisopropilatrazina (DIA) e hidroxiatrazina (HAT). A separação foi obtida por eluição passo-a-passo, com fases móveis compostas de acetonitrila (ACN) e tampão Acetato de Amônio/Ácido acético (NH4Ac/HAc) 2,5 mM pH 4,2. A separação na coluna monolítica foi realizada com duas fases móveis: MP1= 15:85 (v v-1) ACN:NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc a uma vazão de 35 µL s-1. A separação na coluna com partículas superficialmente porosas foi efetivada com as fases móveis MP1= 13:87 (v v-1) ACN: NH4Ac/HAc e MP2= 35:65 (v v-1) ACN:NH4Ac/HAc à vazão de 8 µL s-1. A extração por banho de ultrassom em solo fortificado com os herbicidas (100 e 1000 µg kg-1) resultou em recuperações entre 42 e 160%. A separação de DEA, DIA, HAT, SIM e ATR empregando HPLC foi obtida por um gradiente linear de 13 a 35% para a coluna monolítica e de 10 a 35% ACN na coluna com partículas superficialmente porosas, sendo a fase aquosa constituída por tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 15 min. A extração por banho de ultrassom das amostras de solo com presença de ATR, fortificadas com concentrações de 250 a 1000 µg kg-1, proporcionou recuperações entre 40 e 86%. A presença de ATR foi confirmada por espectrometria de massas. Foram realizados estudos de fortificação com ATR e SIM em amostras de água empregando a extração por ponto nuvem com o surfactante Triton-X114. A separação empregando HPLC foi obtida por um gradiente linear de 13 a 90% de ACN para a coluna monolítica e de 10 a 90% de ACN para a coluna empacotada, sempre em tampão NH4Ac/HAc 2,5 mM pH 4,2. Em ambas as colunas a vazão foi de 1,5 mL min-1 e o tempo de análise 16 min. Fortificações entre 1 e 50 µg L-1 resultaram em recuperações entre 65 e 132%. / The use of pesticides has led to increased productivity and quality of agricultural products, but its use brings the intoxication of living beings by the gradual intake of their residues that contaminate soil, water and food. Thus, there is the need for constant monitoring of their concentrations in environmental compartments. For this, there is a quest for development of fast extraction and enrichment methods, at low cost, generating a low volume of waste, contributing to green chemistry. These methods include the extraction assisted by ultrasound bath and the cloud point extraction. After the extraction, the extract obtained can be analyzed by techniques such as High Performance Liquid Chromatography (HPLC) and Sequential Injection Chromatography (SIC) employing modern stationary phases, such as monolithic and superficially porous particles. The use of SIC with either monolithic column (C18, 50 x 4.6 mm) or column packed with superficially porous particles (C18, 30 x 4.6 mm, 2.7 µM particle size) was studied for separating simazine (SIM) and atrazine (ATR), and metabolites, deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (HAT). Separation was obtained by stepwise elution, with a mobile phase consisting of acetonitrile (ACN) and 2.5 mM ammonium acetate / acetic acid (NH4Ac / HAc) pH 4.2 buffer. The separation was performed with two mobile phases: MP1 = 15:85 (v v -1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at a flow rate of 35 µL s-1. The separation in the column with superficially porous particles was carried out with the mobile phases MP1 = 13:87 (v v-1) ACN: NH4Ac / HAc and MP2 = 35:65 (v v-1) ACN: NH4Ac / HAc at 8 µL s-1. The ultrasound bath extraction from a soil fortified with herbicides (100 and 1000 µg kg-1) resulted in recoveries between 42 and 160 %. Separation of DEA, DIA, HAT SIM and ATR was obtained by HPLC employing a linear gradient from 13 to 35% for the monolithic column and from 10 to 35% ACN in the column packed with superficially porous particles, with the aqueous phases consisting of 2.5 mM NH4Ac / HAc buffer pH 4.2. In both columns the flow rate was 1.5 mL min-1 and the analysis time was15 min. Ultrasonic extraction from a soil sample containing ATR, fortified with concentrations from 250 to 1000 µg kg-1, provided recoveries between 40 and 86%. The presence of ATR was confirmed by mass spectrometry. Fortification studies with ATR and SIM were carried out in water samples employing cloud point extraction using Triton-X114 surfactant. The separation was accomplished by HPLC using a linear gradient from 13 to 90 % of ACN for the monolithic column and from 10 to 90 % ACN for the packed column, always in 2.5 mM NH4Ac / HAc pH 4.2 buffer. In both columns the flow rate was 1.5 mL min -1 and the analysis time 16 min. Fortifications between 1 and 50 µg L-1 resulted in recoveries between 65 and 132%.
5

Emprego da análise por injeção sequencial (SIA) e de métodos estatísticos para a otimização de processos oxidativos avançados visando o tratamento de amostras da indústria de tintas / Application of Sequential Injection Analysis (SIA) and Statistical Methods for the Optimization of Advanced Oxidative Processes Aiming the Treatment of Coatings Industry Samples

Allan Cezar Vieira dos Santos 30 July 2010 (has links)
Esta Tese descreve o emprego da Análise por Injeção Sequencial (SIA) e de métodos estatísticos visando a otimização do tratamento de amostras da indústria de tintas através de Processos Oxidativos Avançados (POA\'s), mais especificamente através das reações de Fenton e foto-Fenton. Estudos foram realizados com o composto modelo vermelho de alizarina S para a otimização de parâmetros da reação de Fenton e o com sal tetrassódico de ácido 3,4′,4″,4″′-tetrassulfônico de ftalocianina de cobre para a otimização de parâmetros da reação de foto-Fenton em um foto-reator desenvolvido em laboratório. Nas condições obtidas com SIA, foi observada a degradação de 99,7% de alizarina e de 97% da ftalocianina de cobre. Uma amostra de efluente da indústria de tintas também foi considerada; para esta matriz, os resultados apontaram uma mineralização de 79% do efluente após a reação de foto-Fenton e de 45% após a reação de Fenton. / This Thesis describes the use of Sequential Injection Analysis (SIA) and statistical methods aiming the optimization of the treatment processes of coatings samples by Advanced Oxidative Processes (AOP\'s), specifically by Fenton and photo-Fenton reactions. Studies were performed with model compounds, alizarin red S for optimization of Fenton parameters and a copper phthalocyanine-3,4′,4″,4″′-tetrasulfonic acid tetrasodium salt dye for optimization of photo-Fenton parameters in a homemade photo reactor. At SIA established conditions, it was observed a degradation of 99.7% of alizarin and 97% of the phthalocyanine dye. A sample of wastewater from the coatings industry was also considered; for this matrix, results showed a sample mineralization of 79% after photo-Fenton and 45% after Fenton reactions.
6

Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and waste

Galhardo, Cristiane Xavier 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.
7

Potencialidade da injeção seqüencial no monitoramento em tempo real de indicadores de qualidade de águas naturais e residuais / Potentiality of sequential injection in real-time monitoring of indicators of quality of natural water and waste

Cristiane Xavier Galhardo 04 May 2001 (has links)
O presente trabalho apresenta o desenvolvimento de metodologias baseadas no sistema de Análise por Injeção Seqüencial (SIA) para a determinação de fosfato e silicato, nitrito e nitrato, assim como a especiação de Fe(II) e Fe(III) em amostras de interesse ambiental, com ênfase para sistemas aquáticos. Para todas as determinações utilizou-se a espectrofotometria de absorção molecular na região do visível como técnica de detecção. A determinação de fosfato e silicato foi baseada na reação de ambos os ânions com molibdato de amônio em meio ácido e posterior redução do Mo(VI) à Mo(V) com ácido ascórbico. O procedimento SIA foi desenvolvido para contornar a interferência mútua das duas espécies explorando o efeito de complexação do molibdato pelo ácido oxálico. A determinação de nitrito foi baseada na reação de diazotação com sulfanilamida e diclorato de N-1 naftil etilenodiamina (NED), enquanto a determinação de Fe(II) baseou-se na sua complexação com 1,10 fenantrolina. A determinação de nitrato e Fe(III) foi efetuada pelas mesmas reações após a redução a nitrito e Fe(II) em colunas de cádmio e zinco amalgamado, respectivamente. A estabilidade das curvas analíticas foi avaliada em diferentes dias de trabalho, obtendo-se variações não superiores a 5% durante um período de 4 dias. O sistema de injeção seqüencial foi explorado também no sentido de regenerar as colunas redutoras no intervalo de tempo entre duas amostras. A estabilidade das curvas analíticas, a viabilidade de regeneração das colunas redutoras e a possibilidade de realizar a amostragem através de filtração tangencial, permitindo a realização de análises com características de tempo real, sugerem que o sistema de injeção seqüencial tem grande potencial para ser implementado em estações automáticas de monitoramento da fração solúvel de indicadores de poluição em águas naturais e residuais. / The present work presents the development of analytical methodologies based on Sequential Injection Analysis (SIA) for determination of phosphate and silicate, nitrite and nitrate, as well as speciation Fe(II)/Fe(III) in environmental samples with emphasis for aquatic environments. All determinations were performed using molecular absorption spectrophotometry at the visible range of the spectrum as the detection technique. The determination of phosphate and silicate was based on the reaction of both anions with ammonium molybdate in acidic medium, followed by reduction of Mo(VI) to Mo(V) with ascorbic acid. The SIA procedure was developed to avoid the mutual interference of both species exploiting the complexation of the molybdate by oxalic acid. The determination of nitrite was based on the diazotation reaction with sulfanilamide and N-l naphtyl ethylenediamine dihydrochlorine (NED), while the determination of Fe(II) were based on the complexation with 1,10 phenantroline. The determination of nitrate and Fe(III) were based on the same reactions, performed after their reduction to nitrite and Fe(II) in reducing columns containing cooperized cadmium and amalgamated zinc, respectively. The stability of the analytical curves was evaluated in different working days, in which no variations greater than 5% were observed during a period of 4 consecutive days. The sequential injection analysis was exploited to regenerate the reducing columns in the time interval between two sample. The stability of the analytical curves, the easy and automatic regeneration of the reducing columns, as well as the possibility to perform sampling through tangential filtration, which permits the analysis to be performed in real time, are characteristics that show the potential application of the sequential injection systems in automatic stations for monitoring the soluble fraction of pollution indicators in natural waste waters.
8

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica / Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Ribeiro, Luiz Fernando 29 August 2014 (has links)
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de µg L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo, bem como o tempo de deposição no potenciostato. Os limites de detecção e quantificação foram, respectivamente, de 1,3 e 4,3 µg L-1 para o Cu(II), 1,4 e 4,6 µg L-1 para o Pb(II), 0,6 e 1,8 µg L-1 para o Cd(II) e 4,2 e 14 µg L-1 para o Zn(II). Esses limites de detecção e quantificação foram obtidos quando o método funcionou com volume de amostra de 1000 µL, vazão de 10 µL s-1 (durante a etapa de deposição), e utilizando 3 reversões de fluxo (volume de reversão = 950 µL), totalizando um tempo de deposição de 315 segundos. O potenciostato, trabalhando sincronicamente com o sistema SIA operou com potencial de condicionamento de -0,1 V vs. pseudo referência de Ag (100 s), potencial de deposição de -1,0 V para Cu(II), Pb(II) e Cd(II) e de -1,3 V para Zn(II) (315 s), frequência de onda quadrada de 100 Hz, incremento de potencial de 6 mV e altura de pulso de 40 mV. Para determinação de Zn(II) foi necessário depositar Ga0 no eletrodo de trabalho e evitar a formação do intermetálico de Zn0 com Cu0. Estudos de interferentes não apontaram desvios significativos em interferentes aniônicos e catiônicos, mas apresentaram desvios significativos na presença de ácidos húmicos e ácidos fúlvicos. A exatidão do método foi avaliada por estudos de adição e recuperação em amostra de água que resultaram taxas de recuperação próximas de 100%. A exatidão também foi avaliada pelas porcentagens de recuperação das concentrações dos metais da amostra certificada de sedimento CRM-701 submetido ao processo de extração sequencial BCR®. As concentrações obtidas foram testadas pelo teste t de Student, mostrando que os desvios dos valores obtidos em relação aos valores certificados não sugerem a existência de diferenças estatísitcamente significativas. / This dissertation describes the development of a methodology for determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA). Screen printed thin mercury film sensors were used as working electrode in a flow cell. The determinations were made by standard addition, with the SIA system performing the inline dilution of the reference standard solution and forming a segment inside the holding coil containing zones of sample, standard and dilution solutions. The concentration of the standard prepared in this segment generated a current signal undistinguishable from the signal generated by a standard solution of the same concentration prepared manually in a volumetric flask. The limits of quantification and detection were at the level of µg L-1, comparable to those of atomic spectrometry techniques with optic detection, whose instrumental and maintenance costs are significantly higher. With the proposed system the limits of quantification and detection can be increased or lowered by simple change of parameters such as flow rate and number of flow reversals, as well as the deposition time at the potenciostat. The limits of detection and quantification were, respectively, 1.3 and 4.3 µg L-1 for Cu(II), 1.4 and 4.6 µg L-1 for Pb(II), 0.6 and 1.8 µg L-1 for Cd(II) and 4.2 and 14 µg L-1 for Zn(II). These limits of detection and quantification were obtained for a sample volume of 1000 µL, flow rate of 10 µL s-1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion = 950 µL) totalizing a deposition time of 315 seconds. The potentiostat worked synchronically with the SIA system performing a conditioning potential of -0,1 V vs pseudo reference of Ag (100 s), deposition potential of -1,0 V for Cu(II), Pb(II) and Cd(II) or -1,3 V for Zn(II) (315 s), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For determination of Zn(II), deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. Studies of interference did not point significant deviation for anionic and ionic potentially interfering substances, but exhibited significant deviations in the presence of humic and fulvic acids. The accuracy of the method was assessed by spike and recovery experiments in a water sample that resulted recovery rates near of 100%. The accuracy was also assessed by percentages of recovery of concentrations of metals in the certified sediment sample CRM-701 undergoing the sequential extraction procedure of BCR®. The concentrations obtained were tested by test t of Student, showing that the deviations of the obtained values don´t suggest the occurrence of statistically significant differences
9

Desenvolvimento de procedimento analítico para a determinação de ácido salicílico em materiais vegetais explorando cromatografia por injeção sequencial / Development of an analytical procedure for the determination of salicylic acid in plant materials exploiting sequential injection chromatography

Barrientos, Marcia Otto 24 July 2015 (has links)
A cromatografia por injeção sequencial com extração em fase sólida (EFS) em linha foi explorada para a determinação de ácido salicílico em amostras vegetais. Uma mini coluna de polietileno, preenchida com sílica funcionalizada C18, foi utilizada para EFS, com tampão fosfato pH 5,2 como eluente. O eluato foi diretamente transferido para a separação cromatográfica em uma coluna monolítica C18, utilizando solução de acetonitrila/tampão acetato pH 4,75 (5:95, v/v) como fase móvel. A detecção foi realizada por fluorescência com excitação em 298 nm e emissão em 406 nm. Os sinais analíticos foram baseados na altura do pico cromatográfico referente ao ácido salicílico em um tempo de retenção de 9.0 min. Os limites de detecção (99,7% de confiança) e quantificação foram estimados em 80 e 240 ?g L-1, respectivamente. A precisão foi estimada através do coeficiente de variação intradia (n = 10) em 0,99% e interdia (3 dias) em 3,6%. A resposta foi linear até 8,0 mg L-1 (r = 0,996). A resolução em relação aos demais componentes da matriz, o número de pratos e a altura equivalente a um prato foram estimados em 6,0; 3980 e 12,6 ?m, respectivamente. Utilizando calibração pelo método das adições de padrão, foram estimadas recuperações entre 74,2 e 96,4% em 4 amostras de folhas de soja. Com estes resultados conclui-se que o procedimento é adequado à determinação de ácido salicílico nos materiais vegetais com a remoção de interferentes em linha, tendo as vantagens de ser um procedimento rápido (ca. 17 min por determinação), limpo (consumo de ca. 320 ?L de acetonitrila por determinação), de custo relativamente baixo, suficientemente sensível e seletivo / Sequential injection cromatography with on-line solid phase extraction (SPE) was explored for the determination of salicylic acid in vegetable samples. A polyethylene column filled with C18-bonded silica was used for SPE, with a phosphate buffer pH 5.2 as eluent. The treated extract was directly sent towards chromatographic separation in a C18 monolithic column with an acetonitrile/acetate buffer solution, pH 4,75 (5:95, v/v) as mobile phase before fluorescence detection (excitation at 298 nm and emission at 406 nm). The analytical signals were based on peak height at the 9.0 min retention time. Limits of detection (99.7% confidence level) and quantification were estimated at 80 and 240 ?g L-1. Precision was estimated through intraday coefficient of variation (n = 10) at 0.99% and interday (3 days) at 3.6 %. A linear response up to 8.0 mg L-1 was estimated (r = 0.996). Resolution, number of plates and the height equivalent to one plate were estimated at 6.0, 3980 and 12,6 ?m, respectively. With calibration by the standard additions method recoveries within 74.2 and 96.4 % were estimated to four soy leaves samples. Thus, the procedure is suitable for the determination of salicylic acid in the extracts with on-line removal of interferences, being a rapid (ca. 17 min per determination), clean (ca. 320 ?L of acetonitrile by determination), inexpensive, and suitably sensitive and selective
10

Determinação simultânea de Cu(II), Pb(II), Cd(II) e Zn(II) em águas e sedimentos usando análise por injeção sequencial (SIA) com detecção voltamétrica / Simultaneous determination of Cu(II), Pb(II), Cd(II) and Zn(II) in waters and sediments using sequential injection analysis (SIA) with voltammetric

Luiz Fernando Ribeiro 29 August 2014 (has links)
Esta dissertação descreve o desenvolvimento de uma metodologia de determinação de Cu(II), Pb(II), Cd(II) e Zn(II) em amostras ambientais por voltametria de redissolução anódica (ASV) automatizada com sistema de Análise por Injeção Sequencial (SIA). Sensores impressos com o eletrodo de trabalho de filme fino de mercúrio foram utilizados em uma cela de fluxo. As determinações foram feitas por adição de padrão, com o sistema SIA fazendo a diluição em linha da solução padrão de referência e formando na bobina coletora e auxiliar um segmento contendo as zonas de amostra, solução padrão e solução de diluição. A concentração do padrão preparada nesse segmento gerou um sinal de corrente indistinguível do sinal gerado por uma solução padrão de mesma concentração preparada em batelada em balão volumétrico. Os limites de quantificação e detecção foram da ordem de µg L-1, comparáveis à de técnicas de espectrometria atômica com detecção óptica, cujos custos instrumentais e de manutenção são significativamente maiores. Com o sistema proposto os limites de quantificação e detecção podem ser aumentados ou diminuídos pela simples alteração dos parâmetros como vazão e número de reversões de fluxo, bem como o tempo de deposição no potenciostato. Os limites de detecção e quantificação foram, respectivamente, de 1,3 e 4,3 µg L-1 para o Cu(II), 1,4 e 4,6 µg L-1 para o Pb(II), 0,6 e 1,8 µg L-1 para o Cd(II) e 4,2 e 14 µg L-1 para o Zn(II). Esses limites de detecção e quantificação foram obtidos quando o método funcionou com volume de amostra de 1000 µL, vazão de 10 µL s-1 (durante a etapa de deposição), e utilizando 3 reversões de fluxo (volume de reversão = 950 µL), totalizando um tempo de deposição de 315 segundos. O potenciostato, trabalhando sincronicamente com o sistema SIA operou com potencial de condicionamento de -0,1 V vs. pseudo referência de Ag (100 s), potencial de deposição de -1,0 V para Cu(II), Pb(II) e Cd(II) e de -1,3 V para Zn(II) (315 s), frequência de onda quadrada de 100 Hz, incremento de potencial de 6 mV e altura de pulso de 40 mV. Para determinação de Zn(II) foi necessário depositar Ga0 no eletrodo de trabalho e evitar a formação do intermetálico de Zn0 com Cu0. Estudos de interferentes não apontaram desvios significativos em interferentes aniônicos e catiônicos, mas apresentaram desvios significativos na presença de ácidos húmicos e ácidos fúlvicos. A exatidão do método foi avaliada por estudos de adição e recuperação em amostra de água que resultaram taxas de recuperação próximas de 100%. A exatidão também foi avaliada pelas porcentagens de recuperação das concentrações dos metais da amostra certificada de sedimento CRM-701 submetido ao processo de extração sequencial BCR®. As concentrações obtidas foram testadas pelo teste t de Student, mostrando que os desvios dos valores obtidos em relação aos valores certificados não sugerem a existência de diferenças estatísitcamente significativas. / This dissertation describes the development of a methodology for determination of Cu(II), Pb(II), Cd(II) and Zn(II) in environmental samples by anodic stripping voltammetry (ASV) automated by Sequential Injection Analysis (SIA). Screen printed thin mercury film sensors were used as working electrode in a flow cell. The determinations were made by standard addition, with the SIA system performing the inline dilution of the reference standard solution and forming a segment inside the holding coil containing zones of sample, standard and dilution solutions. The concentration of the standard prepared in this segment generated a current signal undistinguishable from the signal generated by a standard solution of the same concentration prepared manually in a volumetric flask. The limits of quantification and detection were at the level of µg L-1, comparable to those of atomic spectrometry techniques with optic detection, whose instrumental and maintenance costs are significantly higher. With the proposed system the limits of quantification and detection can be increased or lowered by simple change of parameters such as flow rate and number of flow reversals, as well as the deposition time at the potenciostat. The limits of detection and quantification were, respectively, 1.3 and 4.3 µg L-1 for Cu(II), 1.4 and 4.6 µg L-1 for Pb(II), 0.6 and 1.8 µg L-1 for Cd(II) and 4.2 and 14 µg L-1 for Zn(II). These limits of detection and quantification were obtained for a sample volume of 1000 µL, flow rate of 10 µL s-1 (during the deposition step), and utilizing 3 flow reversals (volume of reversion = 950 µL) totalizing a deposition time of 315 seconds. The potentiostat worked synchronically with the SIA system performing a conditioning potential of -0,1 V vs pseudo reference of Ag (100 s), deposition potential of -1,0 V for Cu(II), Pb(II) and Cd(II) or -1,3 V for Zn(II) (315 s), square wave frequency of 100 Hz, potential step of 6 mV and pulse height of 40 mV. For determination of Zn(II), deposition of Ga0 on the working electrode was necessary to avoid the formation of intermetallic between Zn0 and Cu0. Studies of interference did not point significant deviation for anionic and ionic potentially interfering substances, but exhibited significant deviations in the presence of humic and fulvic acids. The accuracy of the method was assessed by spike and recovery experiments in a water sample that resulted recovery rates near of 100%. The accuracy was also assessed by percentages of recovery of concentrations of metals in the certified sediment sample CRM-701 undergoing the sequential extraction procedure of BCR®. The concentrations obtained were tested by test t of Student, showing that the deviations of the obtained values don´t suggest the occurrence of statistically significant differences

Page generated in 0.1255 seconds