• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 1
  • 1
  • Tagged with
  • 14
  • 14
  • 14
  • 8
  • 7
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação dos processos de nitrificação e desnitrificação das águas residuárias de uma indústria química / Evaluation of nitrification-denitrification processes of wastewater of chemical industry

Márcio Nemer Machado Sassim 24 May 2001 (has links)
Um sistema de tratamento constituído de um reator anaeróbio de mistura completa e um reator anaeróbio compartimentado (ABR) foi operado durante 140 dias para estudar os efeitos do pré-tratamento das águas residuárias de uma indústria química, por carvão ativado em pó (CAP), e suas implicações nos processos de nitrificação e desnitrificação. Utilizou-se, no pré-tratamento do resíduo, duas concentrações de carvão ativado em pó. Para aplicação de 10 mg/l de CAP a remoção de DQO foi de 60% e a de NTK foi de 50%. Nesta fase, os processos de remoção de nitrogênio foram plenamente viabilizados. Para 5 mg/l de CAP a remoção de DQO foi de 44% e a remoção de NTK 46%, neste período se observou inibição por metais pesados e acúmulo de nitrito no sistema. / A treatment system composed of both an aerobic complete-mix reactor and a anaerobic baftled reactor (ABR) was operated for 140 days to study the effects of the treatment of wastewater chemical industry by powdered activate carbon (PAC) and its implications in nitrification - denitrification processes. In the residue preliminary treatment, two concentrations of PAC were used. For the application of 10 mg/l of CAP the removal of COD was 60% and the removal of TKN was 50%. In this phase, the processes of nitrogen removal were possible to be completely carried out. For 5 mg/l of CAP, the removal of COD was 44% and the removal of TKN 46%. In this period, the inhibition by heavy metaIs and nitrite accumulation in the system was observed.
12

Efeitos da recirculação em reatores anaeróbios compartimentados no tratamento de vinhaça / Effects of recirculation in anaerobic baffled reactors in vinasses treatment

Guilherme Araujo Vuitik 27 July 2017 (has links)
A digestão anaeróbia é uma potencial solução para a destinação dos grandes volumes de vinhaça gerada em biorrefinarias de cana-de-açúcar. A alta concentração de matéria orgânica presente na vinhaça é uma questão importante a ser considerada, uma vez que as populações microbianas anaeróbias, principalmente metanogênicas, são sensíveis a sobrecargas orgânicas. Uma série de configurações de reatores, bem como diferentes estratégias de partida e operação tem sido aplicadas ao tratamento de vinhaça, como a recirculação do efluente tratado, a qual é usualmente empregada para prevenir eventos de sobrecarga orgânica. O objetivo deste estudo foi determinar a influência da recirculação de efluentes em reatores anaeróbios compartimentados (RAC) tratando águas residuárias concentradas, uma vez que a literatura não é conclusiva sobre os efeitos da recirculação neste tipo de reator. Para atingir esse objetivo, foi utilizada uma abordagem dupla: experimental e modelagem matemática. Um RAC com 4 compartimentos em série em escala de bancada foi alimentado com vinhaça de cana-de-açúcar (DQO = 18,0 g/L) e monitorado durante 273 dias. Os parâmetros cinéticos e de transferência de massa do reator foram obtidos e utilizados para criar um modelo matemático para a conversão da matéria orgânica no software Matlab®. Tanto os dados operacionais como os parâmetros cinéticos mostraram que a elevada concentração de DQO fez com que o RAC não se comportasse como um sistema de duas fases, bem como a recirculação não resultasse em melhorias relevantes de desempenho. O modelo matemático concordou com os dados operacionais e mostrou que, em termos de capacidade de conversão, o uso de elevadas taxas de recirculação não é necessário para um adequado desempenho do RAC, uma vez que a cinética bioquímica observada não foi expressivamente limitada pela concentração de substrato. / Anaerobic digestion is a potential approach to handle the large volume of vinasse generated in sugarcane biorefineries. The high concentration of organic matter present in vinasse is an important issue to be considered, since anaerobic microbial populations, mainly methanogens, are sensitive to organic overloads. A serie of reactors configurations, as well as different startup and operating strategies, have been applied to the treatment of vinasse, so that the recirculation of the treated effluent is usually used to prevent organic overloading events. The aim of this study was to determine the influence of effluent recirculation in anaerobic baffled reactors (ABR) treating high concentrated wastewater, since literature is not conclusive about its effects. To achieve this aim an experimental and mathematical modeling dual approach was employed. A bench-scale ABR with four serial baffleds was fed with sugarcane vinasse (COD = 18,0 g/L) and monitored for 273 days. Kinetic and mass transfer parameters were obtained and used to create a mathematical model for the organic matter conversion in Matlab®. Both the operating data and the kinetic parameters showed that at high COD concentrations the ABR does not behave as a two-stage system, as well as recirculation did not result in relevant performance improvements. The mathematical model agreed with the operational data and showed that, in terms of conversion capacity, the use of high recirculation ratios is not necessary for suitable ABR performance, since the observed biochemical kinetics were not high limited by the concentration of substrate.
13

Möglichkeiten zur Behandlung saisonal anfallender Abwässer in ländlich strukturierten Gebieten durch Anpassung der Bemessungsgrundlagen und temporäre Aktivierung interner Reserven

Schalk, Thomas 13 November 2017 (has links) (PDF)
Vor dem Hintergrund saisonaler Einflussfaktoren stellen ländlich strukturierte Gebiete besondere Anforderungen an Bemessung und Betrieb von Kläranlagen. Tourismus bildet neben landwirtschaftlich bedingten Ernte- und Verarbeitungskampagnen den bedeutendsten Faktor für saisonale Belastungsschwankungen. Da der größte Teil der Fremdenverkehrseinrichtungen über weniger als 100 Übernachtungsplätze verfügt, besteht bei fehlendem Kanalanschluss ein entsprechender Bedarf an Klein- und Kleinen Kläranlagen zur Behandlung der anfallenden Abwässer. Die Bemessung von Kläranlagen der Größenklasse 1 wird bei fehlenden Messwerten auf Grundlage der im ATV-DVWK-A 198 (2003) als 85-%-Perzentil angegebenen einwohnerspezifischen Frachten durchgeführt. Abwasser aus einfachen Fremdenverkehrseinrichtungen wie Campingplätzen und Hütten weist im Vergleich zur üblichen kommunalen Abwasserzusammensetzung bezogen auf CSB und BSB5 höhere Anteile an Stickstoff- und Phosphorverbindungen auf. Die spezifischen Stickstofffrachten liegen i. M. bei 10 – 11 g/P/d, die spezifischen CSB-Frachten bei i. M. 52 – 68 g/P/d. Die tatsächlichen Frachten werden von der Ausstattung (Restaurant, Wäscherei, etc.) der jeweiligen Unterkunft beeinflusst und sind in der Bemessung gesondert zu berücksichtigen. Für die Behandlung saisonal anfallender Abwässer eignen sich Verfahren mit großem vorgeschaltetem Puffervolumen oder Anlagen mit großem internem Puffer, wie z. B. Bodenfilteranlagen. Anaerobe Vorbehandlungsanlagen wie Anaerobic Baffled Reactors (ABR) können bei entsprechenden Temperaturen zur Frachtentlastung nachgeschalteter aerober Stufen beitragen. Unter gemäßigten Klimabedingungen werden inklusive Sedimentationsprozessen in Vorklärbecken i. M. 50 % des zugeführten CSB eliminiert. Aufgrund der starken Temperaturabhängigkeit des CSB-Abbaus, der Dauer des Einfahrbetriebs, der Empfindlichkeit gegenüber zu hohem Schlammabzug und des nicht berechenbaren Feststoffabtriebs ist unter gemäßigten Klimabedingungen und ohne technische Weiterentwicklung des Verfahrens keine über den Wirkungsgrad von Absetzanlagen hinausgehende Eliminationsleistung bei der Bemessung kalkulierbar. Für saisonal belastete Bodenfilter stellt die Abminderung des Flächenbedarfs bzw. die Steigerung der CSB-Flächenbelastung analog zum nicht belasteten Zeitraum eine betriebssichere und wirtschaftliche Lösung dar, bei der die Einhaltung der Mindestanforderungen gewährleistet ist. Bei geforderter Nitrifikation ist aufgrund des hohen TKN-Konzentrationsniveaus im Abwasser aus Fremdenverkehrseinrichtungen ein Wirkungsgrad von > 95 % für die TKN-Elimination erforderlich. Im Abwasser enthaltene Hemmstoffe, insbesondere in Vorkläranlagen gebildetes Sulfid, können die Nitrifikation beeinträchtigen. Dabei werden Ammoniumoxidation und Nitritoxidation gehemmt. Charakteristisch sind hohe NH4-N- und NO2-N-Konzentrationen im Ablauf (Extremwerte bis zu 55 mg NO2-N/l). Während sich Nitritoxidierer über mehrere Jahre an dauerhaft hohe Sulfidkonzentrationen adaptieren können, wird die Ammoniumoxidation direkt über die Sulfidkonzentration beeinflusst. / In rural communities seasonal factors complicate design and operation of wastewater treatment plants. Tourism as well as agricultural harvesting and processing campaigns are the major causes for seasonal load variations. Due to the fact that accommodation capacities in rural tourism industry rarely exceed 100 beds small sewage treatment plants are acquired if a connection to a sewer system is not feasible. Small wastewater treatment plants can be designed using the population equivalents (PE). According to the German Water Association spreadsheet ATV-DVWK-A 198, PEs are defined as the 85-%-percentile input load. Wastewater of basic accommodations like camping sites and lodges contains higher levels of nitrogen and phosphorous compounds than 'standard' domestic wastewater. The mean specific nitrogen loads reach 10 – 11 g/guest/d, the mean specific COD-load 52 – 68 g/guest/d. The special amenities of vacation homes (restaurant, laundry) affect the real loads and have to be considered in dimensioning. Regarding the treatment of seasonal wastewater, processes with large upstream buffer or large internal buffer, such as constructed wetlands, are suitable. Furthermore, at moderate temperatures anaerobic pretreatment devices, like anaerobic baffled reactors (ABR), can reduce the input load to aerobic post treatment stages. An approximate COD elimination of 50 % can be expected by anaerobic degradation and sedimentation in the ABR in combination with upstream primary clarifiers at around 20 °C. Due to the strong temperature dependence, the long start-up-period, the sensitivity towards fail-desludging, the generation of immediate oxygen demand at low temperatures as well as unpredictable sludge overflow events, it does not seem justified to calculate higher design elimination efficiencies for ABRs than for sedimentation tanks. The design of subsurface vertical flow constructed wetlands with seasonally induced high loading periods are approved for the elimination of organic substances. This accepted assumption was confirmed for the plant under investigation operated at a mean COD-load of 20 g/m²/d, not exceeding the effluent control values for COD in six years. In contrast, oxidation of ammonia and nitrite were inhibited by high sulfide levels (mean sulfide concentration: 48 ± 26 mg/L). Nitrite accumulation reached its peak value at 55 mg NO2-N/L and decreased within 4 years below 1 mg/L due to the adaption of nitrite-oxidizing microorganisms.
14

Möglichkeiten zur Behandlung saisonal anfallender Abwässer in ländlich strukturierten Gebieten durch Anpassung der Bemessungsgrundlagen und temporäre Aktivierung interner Reserven

Schalk, Thomas 05 July 2017 (has links)
Vor dem Hintergrund saisonaler Einflussfaktoren stellen ländlich strukturierte Gebiete besondere Anforderungen an Bemessung und Betrieb von Kläranlagen. Tourismus bildet neben landwirtschaftlich bedingten Ernte- und Verarbeitungskampagnen den bedeutendsten Faktor für saisonale Belastungsschwankungen. Da der größte Teil der Fremdenverkehrseinrichtungen über weniger als 100 Übernachtungsplätze verfügt, besteht bei fehlendem Kanalanschluss ein entsprechender Bedarf an Klein- und Kleinen Kläranlagen zur Behandlung der anfallenden Abwässer. Die Bemessung von Kläranlagen der Größenklasse 1 wird bei fehlenden Messwerten auf Grundlage der im ATV-DVWK-A 198 (2003) als 85-%-Perzentil angegebenen einwohnerspezifischen Frachten durchgeführt. Abwasser aus einfachen Fremdenverkehrseinrichtungen wie Campingplätzen und Hütten weist im Vergleich zur üblichen kommunalen Abwasserzusammensetzung bezogen auf CSB und BSB5 höhere Anteile an Stickstoff- und Phosphorverbindungen auf. Die spezifischen Stickstofffrachten liegen i. M. bei 10 – 11 g/P/d, die spezifischen CSB-Frachten bei i. M. 52 – 68 g/P/d. Die tatsächlichen Frachten werden von der Ausstattung (Restaurant, Wäscherei, etc.) der jeweiligen Unterkunft beeinflusst und sind in der Bemessung gesondert zu berücksichtigen. Für die Behandlung saisonal anfallender Abwässer eignen sich Verfahren mit großem vorgeschaltetem Puffervolumen oder Anlagen mit großem internem Puffer, wie z. B. Bodenfilteranlagen. Anaerobe Vorbehandlungsanlagen wie Anaerobic Baffled Reactors (ABR) können bei entsprechenden Temperaturen zur Frachtentlastung nachgeschalteter aerober Stufen beitragen. Unter gemäßigten Klimabedingungen werden inklusive Sedimentationsprozessen in Vorklärbecken i. M. 50 % des zugeführten CSB eliminiert. Aufgrund der starken Temperaturabhängigkeit des CSB-Abbaus, der Dauer des Einfahrbetriebs, der Empfindlichkeit gegenüber zu hohem Schlammabzug und des nicht berechenbaren Feststoffabtriebs ist unter gemäßigten Klimabedingungen und ohne technische Weiterentwicklung des Verfahrens keine über den Wirkungsgrad von Absetzanlagen hinausgehende Eliminationsleistung bei der Bemessung kalkulierbar. Für saisonal belastete Bodenfilter stellt die Abminderung des Flächenbedarfs bzw. die Steigerung der CSB-Flächenbelastung analog zum nicht belasteten Zeitraum eine betriebssichere und wirtschaftliche Lösung dar, bei der die Einhaltung der Mindestanforderungen gewährleistet ist. Bei geforderter Nitrifikation ist aufgrund des hohen TKN-Konzentrationsniveaus im Abwasser aus Fremdenverkehrseinrichtungen ein Wirkungsgrad von > 95 % für die TKN-Elimination erforderlich. Im Abwasser enthaltene Hemmstoffe, insbesondere in Vorkläranlagen gebildetes Sulfid, können die Nitrifikation beeinträchtigen. Dabei werden Ammoniumoxidation und Nitritoxidation gehemmt. Charakteristisch sind hohe NH4-N- und NO2-N-Konzentrationen im Ablauf (Extremwerte bis zu 55 mg NO2-N/l). Während sich Nitritoxidierer über mehrere Jahre an dauerhaft hohe Sulfidkonzentrationen adaptieren können, wird die Ammoniumoxidation direkt über die Sulfidkonzentration beeinflusst. / In rural communities seasonal factors complicate design and operation of wastewater treatment plants. Tourism as well as agricultural harvesting and processing campaigns are the major causes for seasonal load variations. Due to the fact that accommodation capacities in rural tourism industry rarely exceed 100 beds small sewage treatment plants are acquired if a connection to a sewer system is not feasible. Small wastewater treatment plants can be designed using the population equivalents (PE). According to the German Water Association spreadsheet ATV-DVWK-A 198, PEs are defined as the 85-%-percentile input load. Wastewater of basic accommodations like camping sites and lodges contains higher levels of nitrogen and phosphorous compounds than 'standard' domestic wastewater. The mean specific nitrogen loads reach 10 – 11 g/guest/d, the mean specific COD-load 52 – 68 g/guest/d. The special amenities of vacation homes (restaurant, laundry) affect the real loads and have to be considered in dimensioning. Regarding the treatment of seasonal wastewater, processes with large upstream buffer or large internal buffer, such as constructed wetlands, are suitable. Furthermore, at moderate temperatures anaerobic pretreatment devices, like anaerobic baffled reactors (ABR), can reduce the input load to aerobic post treatment stages. An approximate COD elimination of 50 % can be expected by anaerobic degradation and sedimentation in the ABR in combination with upstream primary clarifiers at around 20 °C. Due to the strong temperature dependence, the long start-up-period, the sensitivity towards fail-desludging, the generation of immediate oxygen demand at low temperatures as well as unpredictable sludge overflow events, it does not seem justified to calculate higher design elimination efficiencies for ABRs than for sedimentation tanks. The design of subsurface vertical flow constructed wetlands with seasonally induced high loading periods are approved for the elimination of organic substances. This accepted assumption was confirmed for the plant under investigation operated at a mean COD-load of 20 g/m²/d, not exceeding the effluent control values for COD in six years. In contrast, oxidation of ammonia and nitrite were inhibited by high sulfide levels (mean sulfide concentration: 48 ± 26 mg/L). Nitrite accumulation reached its peak value at 55 mg NO2-N/L and decreased within 4 years below 1 mg/L due to the adaption of nitrite-oxidizing microorganisms.

Page generated in 0.3821 seconds