• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Lokal brand i hyllställningar : En metodutvärdering för beräkning av temperaturer / Localised fire in shelves : An evaluation of methods for calculating temperatures

Troedson, Per, Östlund, Anna January 2016 (has links)
Moderna byggnader kan ställa krav på komplicerade brandtekniska lösningar eftersom de kan vara komplexa och inte bestå av konventionella arkitektoniska byggnadsdelar. De stora komplexa byggnaderna kan medföra att brandförhållandena i byggnaden avviker signifikant från de förhållanden som ligger till grund för de traditionella dimensioneringsmetoderna. När dimensionering av komplexa byggnader inte genomförs med traditionella dimensioneringsmetoder, såsom naturliga eller nominella brandförlopp, kan lokal brand eller avancerade brandmodeller användas. Storleken på den lokala branden som används vid dimensionering kan beräknas enligt Eurokod 1 appendix C där appendix E ska användas för att beräkna brandintensiteten. EKS 10 åberopar att appendix E inte får användas utan istället ska brandintensiteten bestämmas genom Boverkets allmänna råd om brandbelastning (BBRBE). Syftet med arbetet var att studera dimensionerande brand vid tillämpning av lokal brand i hyllställningar där brandintensitet, hyllställningens dimensioner och lagringssätt varieras. De temperaturer som uppkommer i brandens centrumlinje var av intresse att undersöka eftersom förhöjda temperaturer kan påverka bärförmågan i bärverket. Målet med arbetet var att tillhandahålla en komplett metod för dimensionerande brand i livsmedelsbutiker. Två metoder tillhandhölls och de utvärderades mot en tredje beräkningsmetod samt mot flödesberäkningskoden FDS för att tydliggöra vilken av de tre handberäkningsmetoderna som var mest lämplig att använda vid beräkning av temperaturer vid lokal brand. Arbetet har utgått från en typisk hyllställning från ett tidigare arbete som har modellerats i FDS. Dimensionerna på den typiska hyllställningen har varierats i arbetet, där fyra olika bredder och höjder har använts. I hyllställningarna har bränslepaket modellerats och ska motsvara en antagen bränslekonfiguration med varierande brandintensitet. Det resulterade i att 36 scenarier simulerades i FDS i 300 sekunder där antändningen var momentan. Från resultaten kunde två nya beräkningsmetoder tillhandahållas, förenklad faktormetod (FFM) och partialkoefficientmetoden (PKM). De två metoderna utvärderades mot den tidigare Ludvigsson-Rydstedts metod (LRM) samt FDS i fallstudier. Fallstudierna genomfördes på tidigare tillhandahållen data samt från en FDS simulering över ett helt brandförlopp från detta arbete. Slutsatser som erhållits utifrån resultaten och de framtagna beräkningsmetoderna är: Av hyllställningens bredd, höjd och brandintensiteten är bredden den parameter som påverkar de beräknade temperaturerna mest vid lokal brand i hyllställning. De temperaturer som uppkommer vid lokal brand i hyllställning påverkas av både brandeffekten från en hyllställning samt brandintensiteten på bränslepaketens ytor. Vid lokal brand i hyllställning kan bärverk påverkas eftersom de uppkomna temperaturerna i några scenarier översteg den kritiska temperaturen för stål. Appendix C i Eurokod 1991-1-2 kan anpassas till brand i hyllställningar om hänsyn tas till brandens startpunkt samt projicerad brandeffekt. 2/3 av hyllställningens höjd är mest lämplig att använda som starthöjd för branden i de framtagna metoderna. Generellt visade metodutvärderingen att LRM gav temperaturer som var konservativa i förhållande till FDS. PKM gav temperaturer som stämde överens med temperaturerna från FDS medan FFM gav något lägre temperaturer jämfört med PKM.
2

Brandteknisk dimensionering av limträkonstruktioner : En jämförelse mellan förenklad och analytisk dimensionering med avseende på materialåtgång / Fire design of glued laminated timber structures : A comparison between the simplified and analytical design approach considering material use

Högås, Gabriel, Kuhail, Rami January 2021 (has links)
This thesis examines the possibility of saving material by using analytical design of fire protection of glued laminated timber structures instead of the standard simplified design approach. The thesis is based on an existing store building (building class Br2 and occupancy class 2B) where Tyréns AB has determined a fire exposure specific for the store building, which is used to simulate 30 minutes of fire. The result from the simulation is then used in this thesis to evaluate the effects of said fire on a glued laminated timber structure. The analysis results in the assumption of a laterignition, since the temperature development varies from the standard fire curve used in thesimplified design approach. The thesis consists of several steps. First a glued laminated timber structure consisting of a column and beam system is designed for load bearing capacity in the ultimate and service limit state according to Eurocode. The structure is then verified for accidental actions with fire as the main action according to Eurocode using simplified design. Subsequently the same verification is carried out using the analytical design approach with the specific fire exposure. The columns are not verified since they are assumed to be exposed to direct flame impact and immediate ignition. The columns are also required to be covered with ignition retardant protection according to BBR. The result shows that no saving in material can be obtained for lower fire classes. The main reason for this is the fact that the structure design for load bearing capacity in the ultimate and service limit state is large enough to resist fire for up to 90 minutes without structural failure. For higher fire classes than R90, a potential saving in material can be achieved by using the analytical design approach. This is however deemed irrelevant, since fire classes above R30 are uncommon for these types of buildings. / I detta examensarbete undersöks möjligheten att minska materialåtgången för limträkonstruktioner genom att utföra en analytisk i stället för en förenklad brandteknisk dimensionering. Arbetet baseras på en existerande butikslokal (byggnadsklass Br2 och verksamhetsklass 2B) där Tyréns AB har tagit fram ett troligt brandförlopp i byggnaden som sedan simuleras i 30 minuter. Resultatet används i detta arbete för att utvärdera hur en limträstomme skulle påverkas vid brand i byggnaden. Analysen medför att en senare antändning för limträet kan antas, då temperaturutvecklingen ser annorlunda ut jämfört med standardbrandkurvan som används vid förenklad brandteknisk dimensionering. Arbetet består av flera steg. Först dimensioneras en limträstomme bestående av ett pelar-balksystem för butikslokalen för bärighet i brott- och bruksgränstillståndet enligt Eurokod. Sedan kontrolleras konstruktionen för ett brandlastfall med ett standardiserat brandförlopp, varpå samma kontroll utförs för balkarna enligt analytisk dimensionering med det specifika brandförloppet. Pelarna kontrolleras inte enligt det specifika brandförloppet eftersom dessa antas utsättas för direkt flampåverkan med momentan antändning. Dessutom innefattas de av ytskiktskrav enligt BBR, som kräver att de skyddas med tändskyddande beklädnad. Resultatet visar att materialåtgången inte kan minskas för lägre brandklasser. Detta beror på att dimensionerna som krävs i brott- och bruksgränstillståndet är tillräckligt stora för att konstruktionen ska klara över 90 minuters brandpåverkan utan brott. För högre brandklasser än R90 finns potential för minskning av materialåtgången genom analytisk dimensionering med ett specifikt brandförlopp. Detta anses dock inte relevant då högre brandklasser än R30 sällan förekommer i denna typ av byggnad.
3

Brandskydd i byggnader med exponerad stomme av KL-trä : En kartläggning av olika brandtekniska lösningar för flerbostadshus

Öberg, Andreas, Lejdström, Fredrik January 2021 (has links)
Purpose: The purpose with this work has been to investigate and map selected fireprotection methods in a number of projects. The possibilities and limitations with exposedCLT have been investigated. Method: The method consists of a literature study, interviewstudy, construction site visit and survey. The literature study has been carried out with theaim of presenting relevant facts to the subject and creating a basis for the interview study.The interviews were conducted with fire consultants for the work´s investigated projects.Two of the projects also included construction site visit, of which one of the projects belongsto the partner of this work, Peab. During the visits of the construction sites a tour of thebuilding were carried out and shown where the exposed CLT was placed. The results from theinterviews and construction sites visits are the basis for the survey. Results: The resultsshow that analytical dimension of the fire protection is required when constructing multistory residence with internally exposed CLT. Limitations with exposed CLT are due, amongother things, to the fact that untreated wood does not fulfils the requirements set in BBR forthe surface layer. Delamination contributes to increased fire load as the underlaying slats areexposed to fire. The current study contains two projects carried out with exposed CLT,Notuddsparken and ETC apartment buildings. The projects have dimensioned each withanalytical dimension but with different fire protection methods. Notuddsparken has beenconstructed with automatic sprinkler systems and the ETC apartment buildings have beenconstructed with fire protection impregnation of the exposed CLT. Conclusions:Conclusions established in the work shows that when using exposed CLT analyticaldimension of the fire protection is required. Most of the fire consultants in this work haveexpressed that they do not feel comfortable with dimensioning fire protection for buildingswith exposed CLT, based on the current state of knowledge.

Page generated in 0.1474 seconds