• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 2
  • 1
  • Tagged with
  • 42
  • 17
  • 17
  • 15
  • 10
  • 10
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de eficiência para múons do sistema de veto do experimento Neutrinos-ANGRA / A study for the muon efficiency of the veto system for the Neutrinos-ANGRA experiment

Santos, Lucas Mendes, 1988- 26 August 2018 (has links)
Orientador: Ernesto Kemp / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-26T09:14:52Z (GMT). No. of bitstreams: 1 Santos_LucasMendes_M.pdf: 4540067 bytes, checksum: e343af03dff0bc991b7d23f46a50a44b (MD5) Previous issue date: 2014 / Resumo: O neutrino, atualmente, é uma das partículas de maior interesse para estudo. Seu comportamento oscilatório requer que os neutrinos tenham massa, em escalas desafiadoras para uma simples acomodação com o mecanismo de Higgs possibilitado pelas simetrias eletrofracas. Do ponto de vista de detecção, sua baixa secção de choque introduz grande dificuldade no projeto de detectores eficientes. O Projeto Neutrinos-ANGRA visa, através da detecção de neutrinos, monitorar o reator ANGRA-II situado no Complexo Nuclear de Angra dos Reis - Rio de Janeiro. Para tanto, propõe utilizar um detector de radiação Cherenkov em água, instalado na superfície. Contudo, a esse nível, as taxas de ruído provenientes principalmente de raios cósmicos, são ordens de grandeza maior que a frequência efetiva da passagem do neutrino pelo material ativo. Em uma proposta para reduzir essas taxas, o alvo central será circundado com uma blindagem com elementos ativos e passivos. Nesta dissertação foi dado um enfoque especial à blindagem ativa quanto a incidência de múons, principal componente da radiação cósmica, sobre o detector. Neste estudo foram simulados 3×10^(6)múons não correlacionados temporalmente, porém obedecendo parâmetros bem estabelecidos das distribuição angular e de energia, e foi observado o comportamento da eficiência da blindagem à diferentes critérios de corte. Por fim, foram analisadas as taxas de ruídos aleatórios (não-correlacionados), fixando com uma das partículas participantes o múon. Foi possível determinar um critério de trigger para ao sistema de veto ativo (sinal > 50 fotoelétrons). Nestas condições, o sistema mostrou-se 99,73% eficiente, reduzindo a taxa de sinal:ruído, considerando a presença de pelo menos um múon, de 0,6:1 para 22:1 / Abstract: The neutrino is currently one of the particles of greatest interest to study. its oscillatory behavior requires that neutrinos have mass, in challenging scales for a simple accommodation with the Higgs mechanism enabled by the electroweak symmetry. From the viewpoint of detection, the low cross-section introduces a great distress in designing efficient detectors. The Neutrino-ANGRA Project aims, through the detection of neutrinos, monitor ANGRA-II reactor located in Angra dos Reis Nuclear Complex - Rio de Janeiro. We propose to use a detector of Cherenkov radiation in water, installed on the surface. However, at this level, rates of noise mainly from cosmic rays, are orders of magnitude greater than the effective frequency of the passage of the neutrino active material. In a bid to reduce these rates, the central target will be surrounded with a shield with active and passive elements. In this work a special focus to the active shielding as the incidence of muons, the main component of cosmic radiation on the detector, was given. This study simulated muon 3×10^(6) time-uncorrelated but obeying the well-established angular distribution and energy parameters, and the behavior of the shielding efficiency of different criteria cutting was observed. Finally, the rates of (uncorrelated) random noise, with a setting of the muon particle participants were analyzed. It was possible to derive a criterion to trigger the active veto (signal > 50 photoelectrons) system. Accordingly, the system proved to be 99.73% efficient, reducing the rate signal:noise, whereas the presence of at least one muon from 0.6: 1 to 22:1 / Mestrado / Física / Mestre em Física
2

Angra Pequeña ...

Hodge, Amelia Lawrence, January 1936 (has links)
Inaug.-diss.--München. / Biography. Text in English. Bibliography: p. [90-91].
3

Angra Pequeña ...

Hodge, Amelia Lawrence, January 1936 (has links)
Inaug.-diss.--München. / Biography. Text in English. Bibliography: p. [90-91].
4

Análise do comportamento da contenção do reator Angra 2 durante um acidente de base de projeto / Analysis of the behavior of the Angra 2 reactor containment during a design basis accident

Silva, Dayane Faria 05 May 2017 (has links)
Este trabalho visa verificar a integridade da contenção do reator de Angra 2, com uma abordagem mais realista, da possibilidade de conter todos os radionuclídeos gerados durante Acidentes de Perda de Refrigerante Primário por Grande Ruptura (Large Break Loss of Coolant Accident - LBLOCA). Além disso, essas informações são utilizadas para o cálculo mais realista do Pico de Temperatura do Encamisamento (PTE) da vareta mais realista do núcleo deste reator durante esse acidente. Os resultados desse estudo possibilitarão verificar a integridade da Planta após a ocorrência de acidentes considerados base de projeto. Alguns dos programas utilizados para analisar a contenção de uma usina nuclear são o RELAP5 e o COCOSYS. Esses códigos computacionais são ferramentas de análise que preveem as condições termohidráulicas dentro de um prédio de contenção de um reator refrigerado à água leve. A contenção da planta tipo Pressurized Water Reactor (PWR) é um edifício de concreto revestido internamente por metal e tem limites de pressão que devem ser respeitados durante a ocorrência de um acidente. Os dados de entradas necessários para esta simulação são: adição de massa e energia geradas do estudo de um acidente do tipo LBLOCA com o código RELAP5 da planta em questão. Os resultados da análise do comportamento da contenção da planta nuclear Angra 2 durante os acidentes base de projetos estudados rupturas do tipo guilhotina do circuito primário nas pernas fria e quente foram satisfatórios quando comparados com os apresentados no Relatório de Análise de Segurança (RFAS/A2) da planta e as distribuições de pressão ficaram bem abaixo do valor de pressão de projeto da contenção (6,3bar). / This work aims to verify the integrity of Angra 2 reactor containment by using a more realistic approach for the possibility of containing all radionuclides generated during a Large Break Loss of Coolant Accident (LBLOCA). In addition, this information is used for a more realistic calculation of the Peak Cladding Temperature (PCT) of the hottest area in the reactor during this accident. This study will contribute to the safety of the population from the surrounding areas after the occurrence of a design basis accident. Some of the programs used to analyze the containment of a nuclear plant are RELAP5 and COCOSYS. These computers codes are tools for analysis used for predicting the physical conditions and distributions of radionuclides inside a containment building following the release of material from the primary system in a light-water reactor accident. The containment of the type PWR plant is a concrete building coated internally with metal and has pressure limits to be respected during the occurrence of an accident. The simulation should be performed to ensure that the radionuclides originating from accidents in the plant are not released into the environment. The input data required for this simulation are: mass addition and energy generated from the simulation of an accident of the type Loss of Coolant Accident (LOCA) using RELAP5 code. The results of the analysis of the containment behavior of the Angra 2 nuclear plant during the design basis accidents studied - guillotine-type ruptures of the primary circuit in the cold and hot legs - were satisfactory when compared to those presented in the Final Safety Analysis Report (FSAR) of the plant; moreover, the pressure distributions were below the contention design pressure value (6.3bar).
5

Análise do comportamento da contenção do reator Angra 2 durante um acidente de base de projeto / Analysis of the behavior of the Angra 2 reactor containment during a design basis accident

Dayane Faria Silva 05 May 2017 (has links)
Este trabalho visa verificar a integridade da contenção do reator de Angra 2, com uma abordagem mais realista, da possibilidade de conter todos os radionuclídeos gerados durante Acidentes de Perda de Refrigerante Primário por Grande Ruptura (Large Break Loss of Coolant Accident - LBLOCA). Além disso, essas informações são utilizadas para o cálculo mais realista do Pico de Temperatura do Encamisamento (PTE) da vareta mais realista do núcleo deste reator durante esse acidente. Os resultados desse estudo possibilitarão verificar a integridade da Planta após a ocorrência de acidentes considerados base de projeto. Alguns dos programas utilizados para analisar a contenção de uma usina nuclear são o RELAP5 e o COCOSYS. Esses códigos computacionais são ferramentas de análise que preveem as condições termohidráulicas dentro de um prédio de contenção de um reator refrigerado à água leve. A contenção da planta tipo Pressurized Water Reactor (PWR) é um edifício de concreto revestido internamente por metal e tem limites de pressão que devem ser respeitados durante a ocorrência de um acidente. Os dados de entradas necessários para esta simulação são: adição de massa e energia geradas do estudo de um acidente do tipo LBLOCA com o código RELAP5 da planta em questão. Os resultados da análise do comportamento da contenção da planta nuclear Angra 2 durante os acidentes base de projetos estudados rupturas do tipo guilhotina do circuito primário nas pernas fria e quente foram satisfatórios quando comparados com os apresentados no Relatório de Análise de Segurança (RFAS/A2) da planta e as distribuições de pressão ficaram bem abaixo do valor de pressão de projeto da contenção (6,3bar). / This work aims to verify the integrity of Angra 2 reactor containment by using a more realistic approach for the possibility of containing all radionuclides generated during a Large Break Loss of Coolant Accident (LBLOCA). In addition, this information is used for a more realistic calculation of the Peak Cladding Temperature (PCT) of the hottest area in the reactor during this accident. This study will contribute to the safety of the population from the surrounding areas after the occurrence of a design basis accident. Some of the programs used to analyze the containment of a nuclear plant are RELAP5 and COCOSYS. These computers codes are tools for analysis used for predicting the physical conditions and distributions of radionuclides inside a containment building following the release of material from the primary system in a light-water reactor accident. The containment of the type PWR plant is a concrete building coated internally with metal and has pressure limits to be respected during the occurrence of an accident. The simulation should be performed to ensure that the radionuclides originating from accidents in the plant are not released into the environment. The input data required for this simulation are: mass addition and energy generated from the simulation of an accident of the type Loss of Coolant Accident (LOCA) using RELAP5 code. The results of the analysis of the containment behavior of the Angra 2 nuclear plant during the design basis accidents studied - guillotine-type ruptures of the primary circuit in the cold and hot legs - were satisfactory when compared to those presented in the Final Safety Analysis Report (FSAR) of the plant; moreover, the pressure distributions were below the contention design pressure value (6.3bar).
6

Avaliacao da estabilidade estrutural de contencoes metalicas de centrais nucleares

SILVEIRA, RENATO C. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:42Z (GMT). No. of bitstreams: 1 06918.pdf: 6007370 bytes, checksum: f6ef6e6f5a008b13818a5ead0efc8237 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
7

Avaliacao da estabilidade estrutural de contencoes metalicas de centrais nucleares

SILVEIRA, RENATO C. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:06Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:42Z (GMT). No. of bitstreams: 1 06918.pdf: 6007370 bytes, checksum: f6ef6e6f5a008b13818a5ead0efc8237 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
8

Desemprego e saude: dilemas e perspectivas dos trabalhadores do Estaleiro Verolme, Angra dos Reis/RJ

Sant'Anna, Fatima Cristina Rangel. January 2000 (has links) (PDF)
Mestre -- Escola Nacional de Saude Publica, Rio de Janeiro, 2000.
9

Estudo, desenvolvimento e análise da instrumentação do experimento Neutrinos-Angra

Dornelas, Tony Igor 26 February 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-04T18:18:43Z No. of bitstreams: 1 tonyigordornelas.pdf: 3083272 bytes, checksum: d1e7f6ebbbddea2d63bce105ffc90967 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:37:19Z (GMT) No. of bitstreams: 1 tonyigordornelas.pdf: 3083272 bytes, checksum: d1e7f6ebbbddea2d63bce105ffc90967 (MD5) / Made available in DSpace on 2016-06-07T15:37:19Z (GMT). No. of bitstreams: 1 tonyigordornelas.pdf: 3083272 bytes, checksum: d1e7f6ebbbddea2d63bce105ffc90967 (MD5) Previous issue date: 2015-02-26 / O Projeto Neutrinos-Angra tem como proposta fundamental o desenvolvimento de um detector de anti-neutrinos com o objetivo de medir a potência dissipada de reatores nucleares, em particular, o da usina Angra II, localizada em Angra dos Reis, Rio de Janeiro. O detector, em fase de teste, é composto de uma caixa de formato aproximadamente cúbico capaz de comportar uma tonelada de água, equipada com 48 sensores (fotomultiplicadores). Este detector é composto fundamentalmente de dois módulos, um dedicado à detecção de antineutrinos (chamado de detector alvo) e outro dedicado à detecção de partículas que representam ruído de fundo (chamado de sistema de VETO). Cada sensor é equipado com uma eletrônica de leitura dedicada e um sistema de digitalização de sinal. Estes sinais digitalizados devem passar por algoritmos de seleção para então serem armazenados para análises futuras. A Dissertação aqui referida trata da implementação de um sistema de medidas para caracterização do sensor e da eletrônicas de leitura do Projeto Neutrinos-Angra. As medidas de caracterização realizadas em laboratório serão mostradas junto a uma análise feita com dados coletados a partir do detector alvo, usando raios cósmicos para um primeiro estudo do detector e de seu sistema de leitura integrado. / The Neutrinos-Angra project aims at developing an anti-neutrino detector where the main proposal is to measure the dissipated power of nuclear reactors, in particular, the reactor of Angra II, located in Angra do Reis, Rio de Janeiro. The detector, which is in commissioning phase, comprises a box of around 1 cubic meter of water and it is surrounded by 48 sensor (photo-multipliers). This detector is basically composed by two modules, the inner one (the target) is designed to detect antineutrinos. The outer detector aims at detecting the background noise (the VETO system). Each sensor comprises a customized readout electronics and a signal digitizer system. The digitized signals are processed by an online event selector system in order to store only relevant information. The work described here aims at implementing an environment to commissioning the Neutrinos-Angra sensor’s and its readout electronics. The results of the main test will be described together with the analysis performed using real data acquired with the central detector, but using cosmic rays. Therefore, it allowed a first integration test of the detector and its readout electronics.
10

Repensando políticas públicas em avaliação educacional no município de Angra dos Reis

Costa, Rodrigo Veloso Parkutz 04 June 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-02-29T17:18:14Z No. of bitstreams: 1 rodrigovelosoparkutzcosta.pdf: 811947 bytes, checksum: 110162983b13d27ef0269e8904589701 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-03-03T14:26:48Z (GMT) No. of bitstreams: 1 rodrigovelosoparkutzcosta.pdf: 811947 bytes, checksum: 110162983b13d27ef0269e8904589701 (MD5) / Made available in DSpace on 2016-03-03T14:26:49Z (GMT). No. of bitstreams: 1 rodrigovelosoparkutzcosta.pdf: 811947 bytes, checksum: 110162983b13d27ef0269e8904589701 (MD5) Previous issue date: 2013-06-04 / Esta dissertação tem como objetivo fazer uma análise do programa de avaliação educacional do município de Angra dos Reis, denominado Prova Angra, quanto aos objetivos e obtenção de diagnóstico da rede pública municipal de ensino. Temos visto nos últimos anos o crescente número de programas de avaliação educacional em larga escala. Apesar da vasta publicidade que tem sido dada ao tema, principalmente quando da divulgação dos resultados da Prova Brasil/SAEB, percebemos que em muitas escolas essas avaliações ainda não cumprem parte do propósito a que foram criadas – diagnosticar e reorientar as práticas pedagógicas. No município de Angra dos Reis, essa percepção parece fazer algum sentido. Na condição de professores verificamos empiricamente que pouco ou quase nada vem sendo aproveitado das avaliações aplicadas pelo poder público municipal. Esta constatação ganha forma e força na medida em que realizamos uma série de pesquisas em três escolas públicas municipais e na secretaria de educação do município. Para a realização desta pesquisa utilizamos como metodologia de trabalho: análise documental, entrevista estruturada e pesquisa bibliográfica. A principal referência bibliográfica foi a pesquisa de Brooke e Cunha (2011). Enquanto na análise documental verificamos documentos das Secretarias de Educação dos municípios de Angra dos Reis e Belo Horizonte. Já nas entrevistas buscamos a coordenação do programa Prova Angra e do Avalia BH. Entrevistamos também diretores, professores e pedagogos da Secretaria de Educação de Angra dos Reis. No decorrer da pesquisa verificamos que o atual programa de avaliação de Angra dos Reis – Prova Angra – demonstra algumas falhas e fragilidades em seu desenho, comprometendo sua aplicação e utilização nas escolas como ferramenta de diagnóstico e monitoramento da educação pública municipal. / This thesis aims to analyze the program of educational assessment in the municipality of Angra dos Reis, called Prova Angra, about goals and obtaining diagnostic municipal public schools. We have seen in recent years a growing number of educational assessment programs on a large scale. Despite the wide publicity that has been given to this issue, especially when disclosure of the results of Prova Brazil / SAEB, we realize that many schools do not meet these assessments still part of the purpose they were created - diagnose and redirect teaching practices. In the city of Angra dos Reis, this perception seems to make some sense. Provided teachers found empirically that little or nothing has been tapped rating applied by the municipal government. This finding takes shape and strength in that we conducted a series of surveys in three public schools and the county office of education. For this research we used as working methods: document analysis, structured interviews and literature. The main bibliographic search was Brooke and Cunha (2011). While we found documents in document analysis Departments of Education of the cities of Angra dos Reis and Belo Horizonte. Already in interviews seek to coordinate the program and evaluates Prova Angra and Avalia BH. We also interviewed principals, teachers and educators of the Education Department of Angra dos Reis. During the research found that the current assessment program Angra dos Reis - Prova Angra - shows some flaws and weaknesses in program design, hindering their application and use in schools as a tool for diagnosis and monitoring of municipal public education.

Page generated in 0.0452 seconds