• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 527
  • 25
  • 25
  • 25
  • 23
  • 14
  • 13
  • 13
  • 12
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 537
  • 200
  • 161
  • 101
  • 91
  • 85
  • 81
  • 74
  • 71
  • 71
  • 70
  • 70
  • 69
  • 68
  • 67
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Efeito da fotoativação com LED sobre a microdureza de um compósito em cavidades com diferentes profundidades

Correa Medina, Alberth David January 2005 (has links)
O objetivo deste estudo foi avaliar o comportamento de três aparelhos fotoativadores, sendo que dois aparelhos utilizam a tecnologia de diodos emissores de luz (LED) (Radii-SDI; Single V-Bio art) e o ultimo é um aparelho convencional de lâmpada halógena (XL-2500-3M ESPE), sendo que o primeiro apresenta o diodo emissor de luz na extremidade do aparelho; o segundo apresenta ponteira de fibra óptica turbo e o terceiro apresenta ponteira de fibra óptica convencional. O desempenho dos aparelhos foi analisado por meio da análise de microdureza do fundo de um incremento de 2mm do compósito Z250 (3M ESPE), submetido à polimerização em diferentes profundidades: 2mm, 4mm, 6mm e 8mm. Em todos os casos, o tempo de polimerização adotado foi de 20 s. Para obtenção dos corpos de prova, foi utilizada uma matriz de dentina com uma cavidade de 3mm de diâmetro por 2mm de espessura. Para simular as diferentes profundidades de 2mm, 4mm, 6mm e 8mm, foram utilizados espaçadores de dentina em forma de anel com 2mm, 4mm, e 6mm de espessura sobre a matriz. Para o ensaio de microdureza, foram confeccionados cinco corpos de prova para cada combinação entre aparelho fotoativador e as quatro profundidades, totalizando 60 corpos de prova. . O ensaio foi realizado 15min após a polimerização. Os valores de microdureza foram obtidos a partir de cinco endentações em cada corpo de prova. Os resultados obtidos foram submetidos à análise de variância e ao teste Tukey para comparação entre os aparelhos, em cada profundidade (α=0,05). Os valores médios e desvio padrão da microdureza obtidos com os aparelhos Radii(R), Single V (S) e XL-2500(XL), a 2mm, foram respectivamente: 55,16 (±1,66), 58,56 (±1,77), 51,15 (±2,08), mostrando diferença significativa entre eles, sendo que o melhor desempenho foi obtido pelo S seguido pelo R e pelo XL. A 4mm, os valores foram R= 52,23 (±1,66 ); S= 49,04 (±2,04); XL= 47,34 (±2,69), com melhor desempenho do R em relação a XL, porém sem diferença do S. A 6mm, os valores foram R= 46,40 (±1,07); S= 43,64 (±1,56); XL= 42,12 (±1,72). Com melhor desempenho do R, seguidos pelo S e XL que não mostraram diferença entre si. Já a 8mm, os valores foram R= 41,96 (±1,09); S= 38,36(± 0,87); XL= 40,16 (±1,70), com melhor desempenho do R seguido pelo XL e este pelo S, mostrando diferença significativa entre eles. Comparando os aparelhos LED com a lâmpada halógena, pode-se observar que o Radii teve um desempenho superior a ela em todas as profundidades. Já o Single V foi superior na profundidade de 2mm, similar em 4mm e em 6mm e inferior em 8mm, mostrando que os aparelhos LED tiveram um comportamento diferenciado que talvez possa ser atribuído à presença de uma ponteira turbo no Single V. Também com base nos resultados foi possível concluir que houve uma redução significativa, dos valores de microdureza do fundo do material restaurador com o aumento da profundidade da cavidade para todos os aparelhos.
122

Avaliação das alterações tegumentares produzidas pelo aparelho de Herbst em indivíduos classe II divisão 1º, tratados em diferentes estágios de crescimento

Pereira, Ana Patricia de Sousa [UNESP] 18 May 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-18Bitstream added on 2014-06-13T19:56:53Z : No. of bitstreams: 1 pereira_aps_me_arafo.pdf: 2580064 bytes, checksum: a67d152abefb1c415091c79bd9acff7a (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Esta pesquisa teve como objetivo realizar estudo cefalométrico das alterações tegumentares no tratamento da má oclusão de Classe II com o aparelho de Herbst. No primeiro estudo, avaliou-se as alterações tegumentares em pacientes com má oclusão de Classe II divisão 1, tratados com o aparelho de Herbst, após o pico de crescimento pubertário. A amostra foi composta por 71 indivíduos, sendo um grupo tratado (n=32) com o aparelho de Herbst e outro grupo controle canadense (n=39) com características iniciais semelhantes à do grupo tratado, acompanhado sem tratamento. Utilizou-se o teste t de Student para análise estatística. Concluiu-se que as alterações tegumentares foram maiores na região de lábio inferior e ângulo mentolabial e que a convexidade da face foi reduzida de forma significativa, melhorando a estética facial. No segundo estudo avaliou-se as mudanças tegumentares promovidas pelo aparelho de Herbst, em dois grupos distintos de indivíduos com má oclusão de Classe II divisão 1: Grupo 1: 20 indivíduos com idade inicial de 8 a 10 anos, tratados com o aparelho de Herbst por 7 meses, antes do pico de crescimento pubertário, e, Grupo 2: 24 indivíduos com idade inicial de 13 a 17 anos, tratados por 8 meses, após o pico de crescimento pubertário. Utilizou-se o teste t de Student para análise estatística. O tratamento não promoveu interferência na maxila e lábio superior, independente da fase de crescimento facial. Os incisivos e lábio inferior foram protruídos nos dois grupos e o pogônio tegumentar exibiu projeção significante no grupo pré-pico. Ocorreu diminuição da convexidade facial e esquelética em ambos os grupos e de forma mais proeminentes no grupo pré-pico / This research aims to perform a cephalometric study of soft tissue profile changes in the treatment of Class II division 1 malocclusion with the Herbst appliance. In the first study, the soft tissue changes in patients with Class II division 1 malocclusion, treated with the Herbst appliance, after the pubertal growth peak were evaluated. The sample consisted of 71 individuals, Class II malocclusion division 1 after the pubertal growth peak, divided into two groups: one group treated (n=32) with the Herbst appliance, and the canadian control group (n=39) followed without treatment. Statistical analysis was tested with Student’s t test. . It was demonstrated that changes in soft tissue profile were pronounced in the region of the lower lip and mentolabial angle. The convexity of soft tissue profile was reduced significantly, improving facial aesthetics. In the second study, soft tissue changes promoted by the Herbst appliance in two distinct groups of patients with Class II division 1 malocclusion were evaluated; Group 1: 20 subjects, initial ages between 8 and 10 years treated with the Herbst appliance for 7 months before the pubertal growth peak (pre-peak); Group 2: 24 subjects with initial ages between 13 and 17 years treated with the same unit for eight months after the pubertal growth peak (post-peak). Statistical analysis was tested with Student’s t test. No interference in the maxilla and upper lip position was observed in both groups. The lower incisors proclined and the lower lip protruded in both groups and the projection of soft tissue pogonion in pre-peak group was significantly. There was a reduction of facial convexity with the most prominent changes in the pre-peak group
123

Avaliação cefalométrica das alterações dentárias esqueléticas induzidas pelo uso do aparelho de Herbst no tratamento da má oclusão de classe II, divisão 1ª de Angle - Estudo longitudinal

Dib, Luana Paz Sampaio [UNESP] 02 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-02Bitstream added on 2014-06-13T19:15:31Z : No. of bitstreams: 1 dib_lps_me_arafo.pdf: 916738 bytes, checksum: bccf4c5a5b8970b365f2cd0e715dff45 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este estudo cefalométrico foi desenvolvido com o propósito de avaliar as alterações dentárias e esqueléticas naturais e induzidas pelo uso do aparelho de Herbst. O grupo experimental foi constituído por 15 indivíduos pré-pubertários, leucodermas, com idade média de 9,4 anos (+ ou - 06 meses), de ambos os gêneros, com má oclusão Classe II Divisão 1ª com deficiência mandibular. Foi utilizado para comparação um grupo controle de 15 indivíduos, leucodermas, com má oclusão Classe II Divisão 1ª, não tratados ortodonticamente, pareados quanto às idades óssea e cronológica do grupo experimental, derivados do Burlington Growth Centre, Departamento de Ortodontia da Faculdade de Odontologia, Universidade de Toronto, Canadá. Foram realizadas radiografias em norma lateral iniciais e após 7 meses de tratamento no grupo experimental e no grupo controle as radiografias foram tomadas aos 9 e 10 anos de idade. A análise estatística foi realizada por meio do teste t de Student, com nível de significância de 5%. De acordo com os dados obtidos, verificamos que o uso do aparelho de Herbst resultou numa restrição significativa do crescimento maxilar, enquanto que o efeito do crescimento natural havia sido de aumentar o comprimento da maxila; o crescimento mandibular foi estimulado em ambos os grupos, porém mais intenso no grupo tratado; houve aumento das alturas faciais anterior e posterior no grupo experimental, ao passo que no grupo controle a altura facial posterior não foi alterada; em relação à convexidade facial e a relação maxilo-mandibular houve uma alteração positiva no grupo tratado, enquanto no grupo não tratado elas se mantiveram estáveis; e, o plano mandibular não sofreu alteração em ambos os grupos. As alterações dentárias caracterizaram-se no grupo tratado pela verticalização dos incisivos superiores, distalização dos molares... / This cephalometric study was developed in order to evaluate natural dental and skeletal alterations as well as those induced by the use of Herbst's appliance. The experimental group consisted of 15 pre-pubertal individuals, white children, with mean age of 9.4 years (+ or - 06 months), both male and female, presenting Class II, 1st Division malocclusion and mandibular deficiency. A control group of 15 white children with Class II, 1st Division malocclusion, who were not treated orthodontically, was used for comparison, paired considering bone and chronological ages of the experimental group, originally from Burlington Growth Centre, Orthodontics Department of the University of Toronto Dental School, Canada. Initial and 7-month treatment follow-up radiographs were obtained in lateral take for the experimental group, and for the control group the radiographs were taken at 9 and 10 years of age. Statistical analysis was carried out with Student's test, at significance level of 5%. According to the data obtained, it was verified that the use of Herbst's appliance resulted in a significant restriction of the maxillary growth, while the effect of natural growth had been to increase maxilla length; mandibular growth was stimulated in both groups, however, it was more intense in the group treated; there was an increase in the anterior and posterior facial heights of the experimental group, whereas in the control group the posterior facial height was not altered; considering facial convexity and the maxilla-mandible relationship, there was a positive alteration in the group treated, while in the non-treated group they were kept stable; and, the mandibular plane suffered no alteration in any of the groups. In the treated group, dental alterations were characterized by the verticalization of the maxillary incisors, distal tipping of the maxillary molars, buccal tipping of the mandibular... (Complete abstract, click electronic access below)
124

Avaliação das alterações induzidas pelo aparelho de Herbst no tratamento da má oclusão de classe II de Angle em telerradiografia cefalométrica em norma de 45°

Raveli, Taísa Boamorte [UNESP] 16 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-16Bitstream added on 2014-06-13T19:15:31Z : No. of bitstreams: 1 raveli_tb_me_arafo.pdf: 495931 bytes, checksum: e54647180e1ce6950679b8f3233686ba (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A presente pesquisa foi desenvolvida em dois estudos retrospectivos. O primeiro e segundo estudos avaliaram as alterações dentoesqueléticas induzidas pelo aparelho de Herbst em telerradiografias cefalométricas em norma de 45°. O primeiro estudo utilizou uma amostra de 49 indivíduos em período pré-pico de crescimento pubertário, sendo tratados (n=25) e controle (n=24), período de observação de 7 meses. O segundo utilizou uma amostra de 46 indivíduos em período pós-pico de crescimento pubertário, sendo tratados (n=23) e controle (n=23), período de observação de 8 meses. A análise estatística foi realizada por meio do teste t de Student. O primeiro estudo concluiu que não houve mudanças esqueléticas na fase pré-pico de crescimento pubertário, no perído de tratamento com o aparelho de Herbst e teve alterações dentárias, como mesialização do primeiro molar permanente inferior e distalização do primeiro molar permanente superior. A correção da Classe II se deu predominantemente por alterações dentoalveolares. O segundo estudo concluiu que não houve mudanças esqueléticas significantes na fase póspico de crescimento pubertário e teve alterações dentárias, como mesialização do primeiro molar permanente inferior. A correção da Classe II se deu predominantemente por alterações dentoalveolares / The present retrospective research was divided into two studies. The first and second studies evaluated dentoskeletal changes induced by the use of Herbst appliance through oblique radiographs. The first study had a sample of 49 individuals before peak of pubertal growth divided into treated (n=25) and control (n=24) observed during a 7 months period. The second study had a sample of 46 individuals after peak of pubertal growth divided intro treated (n=23) and control (n=23) observed during a 8 month period. Statistical analysis was made by Student’s t test. The first study concluded that there were no skeletal changes with the treated group before peak of pubertal growth, and there were dental changes as mesialization of lower first molars and distalization of upper first molars. The correction of class II was predominantely dental. The second study concluded that there were no significant skeletal changes with treated group after peak of pubertal growth, and there were dental changes as mesialization of lower first molars. The correction of class II was predominantely dental
125

Estudo de propriedades físicas de materiais adesivos ortodônticos

Seixas, Michela Melissa Duarte [UNESP] 25 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-25Bitstream added on 2014-06-13T20:50:18Z : No. of bitstreams: 1 seixas_mmd_me_ilha.pdf: 666243 bytes, checksum: 52240f181efba99ad50036dbab585732 (MD5) / O avanço tecnológico trouxe grandes benefícios para a prática odontológica. Na ortodontia fixa, a colagem direta dos acessórios ortodônticos revolucionou a confecção de aparelhos ortodônticos. A introdução do condicionamento ácido do esmalte dental permitiu o desenvolvimento e aperfeiçoamento da fixação direta dos acessórios ortodônticos aos dentes, fazendo da colagem direta um procedimento clínico rotineiro. As resinas compostas passaram a ser largamente utilizadas como material de colagem devido às suas propriedades adesivas, e os bráquetes foram confeccionados de modo a apresentarem retenções mecânicas. Para a utilização de um material adesivo em ortodontia, é fundamental que o agente cimentante promova adesão suficiente entre o acessório ortodôntico e a superfície dentária. Outra característica importante é que o mesmo apresente um coeficiente de expansão térmica próximo ao do dente. O estudo da eficiência dos adesivos é sempre uma motivação e tem auxiliado os profissionais a obterem melhores resultados clínicos. Desta forma, este trabalho teve como objetivo avaliar a resistência ao cisalhamento com e sem termociclagem das resinas compostas Concise Ortodôntico e Fill Magic Ortodôntico, por meio de ensaios mecânicos, assim como estudar as diferenças de dilatação térmica entre os materiais do sistema dente-resina-bráquete, utilizando-se da técnica de extensometria. O Concise Ortodôntico apresentou os melhores resultados de resistência ao cisalhamento com e sem termociclagem e um menor coeficiente de expansão térmica comparados aos respectivos resultados de cisalhamento e expansão térmica da resina Fill Magic Ortodôntico. O material utilizado na confecção do bráquete ortodôntico apresentou um coeficiente de expansão térmica mais próximo ao do esmalte dental. Por outro lado, apresentou coeficiente... . / The technological progress brought great benefits in the practice of dentistry. In the orthodontics, the direct bonding of the orthodontic attachments revolutionized the making of the orthodontic appliances. The introduction of the acid etching technique allowed the development and improvement of the direct fixation of the brackets to the teeth, becoming the direct bonding a routine clinical procedure. The composites are used broadly as bonding material due to their adhesive properties and the brackets present good mechanical retention. The material adhesive to be used has to promote enough adhesion between the bracket and the dental surface. Besides, it is important that it presents a coefficient of thermal expansion similar to the one of the tooth. The study of the efficiency of the adhesives systems is always a motivation and it aids the professionals to obtain better clinical results. Therefore, this work had as objective to evaluate the shear bond strength with and without thermoclycling of the composed Orthodontic Concise and Fill Magic, through mechanical tests, as well as to study the thermal expansion of the materials of the tooth-resin-bracket system by extensometry technique. The Concise resin presented the better results of shear bond strength with and without thermoclycling and a smaller coefficient of thermal expansion when compared to the respective results for Fill Magic resin. The bracket’s material presented a coefficient of thermal expansion similar to the dental enamel. On the other hand, its coefficient is smaller than those of the two evaluated resins (twice smaller than to of Concise and three times to of Fill Magic).
126

Desenvolvimento de uma metodologia para controle da qualidade de imagens em equipamentos de tomografia computadorizada de feixe cônico odontológico

Hoffmann, Elias Cantarelli January 2015 (has links)
Made available in DSpace on 2015-06-23T02:05:43Z (GMT). No. of bitstreams: 1 000470853-Texto+Completo-0.pdf: 2786282 bytes, checksum: 202437712e592d5d1814790a5c93c608 (MD5) Previous issue date: 2015 / Cone-beam CT (CBCT) systems have been used for diagnostic radiology of head and neck, and dentomaxillofacial surgery applications. Different dental CBCT devices are being developed and released, with a wide variability of exposure parameters and fields of view. Although they have sufficient diagnostic quality, some of the drawbacks of the dental CBCT devices are their inability of discriminating soft tissue because of its low contrast resolution, and the inaccuracy to give information about soft tissue quality. Standard quality control procedures and phantoms for conventional CT are not fully applicable for CBCT devices. Furthermore, there is a lack of quantitative methods for image quality analysis suitable for dental CBCT. The aim of this study was to develop and implement a feasible methodology for image quality analysis for different dental CBCT devices. The methodology was based on conventional CT quality control procedures, and adapted to overcome the limitations of dental CBCT. A prototype phantom was specially designed to allow the acquisition of image quality parameters relevant for dental imaging. CBCT devices were divided into categories for the analysis, related to their Field of View (FOV): Small Field of View (SFOV) and Full Field of View (FFOV).The following image quality parameters were evaluated: filed uniformity, image noise, contrast-to-noise ratio, CT number accuracy, artifacts, spatial resolution and geometric distortion. Applicability of the methodology was assessed using one SFOV and four different FFOV CBCT devices. Large differences in image quality performance were seen between the CBCT devices. Furthermore, a CT number calibration method was developed and tested, which enables CBCT devices for bone density evaluation. Concluding, a new methodology was implemented and proved to be viable for use on different CBCT devices with a variability of fields of view. Based on the evaluations, the prototype phantom will be optimized and validated for quality assurance on CBCT devices. / Sistemas de tomografia computadorizada por feixe cônico ou CBCT têm sido utilizados para radiologia diagnóstica de cabeça e pescoço, e aplicações em cirurgia bucomaxilofacial. Diferentes CBCT odontológicos estão sendo desenvolvidos e disponibilizados, com uma grande variabilidade dos parâmetros de exposição e campos de visão. Embora tenham qualidade diagnóstica suficiente, algumas das desvantagens dos CBCT odontológicos são a sua incapacidade de discriminar tecidos moles devido a limitações na resolução de contraste e a imprecisão para fornecer informações sobre a qualidade dos tecidos. Procedimentos e simuladores de controle de qualidade para a tomografia computadorizada convencional não são plenamente aplicáveis para equipamentos CBCT. Além disso, há uma falta de métodos quantitativos para a análise da qualidade da imagem adequada para CBCT odontológico. O objetivo deste estudo foi desenvolver e implementar uma metodologia viável para análise de qualidade de imagens em diferentes modelos de equipamentos CBCT odontológicos. A metodologia foi baseada em procedimentos de controle de qualidade de tomógrafos convencionais, e adaptada para superar as limitações da CBCT dentária. Um protótipo de simulador foi projetado especialmente para permitir a aquisição de parâmetros de qualidade de imagem relevantes para a imagem dentária. Os equipamentos CBCT foram divididos em categorias para a análise, relacionadas com seu campo de visão (FOV): pequeno campo de visão (SFOV) e amplo campo de visão (FFOV). Os seguintes parâmetros de qualidade de imagem foram avaliados: uniformidade de campo, o ruído da imagem, razão contraste-ruído, acurácia do número CT, artefatos, resolução espacial e distorção geométrica.A aplicabilidade da metodologia foi avaliada usando um CBCT SFOV e quatro FFOV diferentes. Grandes diferenças no desempenho da qualidade de imagem foram observadas entre os equipamentos. Um método de calibração do número CT foi desenvolvido e testado, permitindo que os equipamentos CBCT possam avaliar a densidade óssea. Concluindo, uma nova metodologia foi implementada e mostrou-se viável para utilização em equipamentos CBCT odontológicos com uma variedade de campos de visão. Com base nas avaliações, o simulador protótipo poderá ser otimizado e validado para garantia da qualidade em equipamentos CBCT.
127

Comparação in vitro da citotoxidade dos anéis ortodônticos com e sem soldagem à prata em diferentes linhagens celulares

Jacoby, Letícia Spinelli January 2016 (has links)
Made available in DSpace on 2016-05-07T12:04:32Z (GMT). No. of bitstreams: 1 000478491-Texto+Parcial-0.pdf: 409701 bytes, checksum: ece1c9e62d9b0d680c9b4a7d64a27079 (MD5) Previous issue date: 2016 / Introduction: The aims of this study were to assess the in vitro cytotoxicity of orthodontic bands, with and without silver solder, and to compare the viability of the HaCaT, HGF, MRC-5, and Vero cell lines, when exposed to orthodontic band extracts. Material and Methods: An MTT assay was performed on the extracts of the tested materials. The culture medium alone was used as a negative control and copper strip extracts were used as a positive control. Results: A one-way Analysis of Variance (ANOVA) showed a difference between all of the groups in all of the cell lines and Tukey’s post-hoc test revealed no significant differences between the stainless steel orthodontic bands and the negative control group. There was a significant difference between the negative control group and the stainless steel orthodontic bands with silver solder joints in the HaCaT and MRC-5 cell lines. A great variability in the percentages of cell viability was observed. According to these results, the stainless steel orthodontic bands did not induce cytotoxic effects on any of the cell lines. When associated with silver solder, the orthodontic bands decreased the cell viability in the HaCaT, HGF, MRC-5, and Vero cell lines, but there was only a statistical significance in the HaCaT and MRC-5 cell lines. Conclusions: More than one type of cell line must be tested in a cytotoxicity assay due to the outcome variability from one cell line to another. / Introdução: Os objetivos deste estudo foram avaliar, in vitro, a citotoxicidade dos anéis ortodônticos com e sem soldagem à prata e comparar a viabilidade celular nas linhagens FGH, HaCaT, MRC-5 e Vero após a exposição aos extratos dos anéis ortodônticos. Materiais e Métodos: Foi realizado o ensaio de redução de MTT após a exposição das culturas celulares aos extratos dos materiais testados. Foram utilizados como controles negativo e positivo, respectivamente, meio de cultura DMEM e extratos de tira de cobre. Resultados: A análise de variância de uma via (ANOVA) mostrou que houve diferença estatisticamente significativa entre os grupos em todas as linhagens avaliadas. O teste de comparações múltiplas de Tukey detectou ausência de diferença significativa entre os grupos controle negativo e anéis ortodônticos de aço inoxidável. Houve diferença estatisticamente significativa entre os grupos controle negativo e anéis ortodônticos de aço inoxidável com soldagem à prata nas linhagens celulares HaCaT e MRC-5. Observou-se grande variabilidade nas percentagens de viabilidade celular entre as linhagens. Conclusões: Ao avaliar a citotoxicidade de anéis ortodônticos com e sem soldagem à prata, existe variabilidade nos resultados quando linhagens diferentes são comparadas. Anéis ortodônticos de aço inoxidável não induziram efeitos citotóxicos em nenhuma das linhagens testadas. Quando associados à solda de prata, os extratos dos anéis ortodônticos reduziram a viabilidade celular nas linhagens FGH, HaCaT, MRC-5 e Vero, embora essa redução tenha ocorrido de forma estatisticamente significativa apenas nas linhagens HaCaT e MRC-5.
128

Análise tridimensional das alterações dento-alveolares em molares superiores após o uso do aparelho de Herbst /

Kameyama, Daniela Cristina. January 2014 (has links)
Orientador: Dirceu Barnabé Raveli / Banca: Luiz Gonzaga gandini Jr. / Banca: Jorge Abrão / Resumo: Este estudo teve como objetivo avaliar tridimensionalmente a altura e espessura óssea alveolar e alterações dentárias no sentido vertical e transversal na maxila após o uso do aparelho de Herbst. A amostra prospectiva foi composta por 23 indivíduos brasileiros, leucodermas, de ambos os gêneros, com idade média de 15.76 ± 1.75 anos, apresentando a má oclusão de Classe II divisão 1, com deficiência mandibular que foram tratados com o aparelho de Herbst por um período de 8 meses. Para essa avaliação foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) obtidas antes (T1) e depois do tratamento (T2) para análise e medição das alterações estruturais: altura e espessura óssea alveolar na região de molares e, alterações dentárias no sentido vertical de molares e transversal (distância e inclinação intermolar). O erro do método foi avaliado pelo Coeficiente de Correlação Intraclasse (ICC) e o teste t pareado foi usado para comparar as medidas obtidas em T1 e T2 com nível de significância de 5%. Os resultados mostraram que o ICC foi elevado para todas as medições (0,95). Houve aumento da altura (0,37mm) e espessura óssea alveolar apenas na lingual da região dos molares superiores sendo que com os terços médio (0,45mm) e apical (0,58mm) tiveram resultados mais significativos. Quanto à relação dentária teve diminuição significativa da angulação intermolar com média de 4,6° (p<0,05). Concluímos que o tratamento ortodôntico com aparelho de Herbst levou a alterações apenas na lingual da altura e espessura óssea alveolar e na angulação intermolar da arcada superior. / Abstract: This study aimed to evaluate three-dimensionally the height and thickness of alveolar bone and dental changes at vertical and crossectional direction after use of Herbst appliance. The prospective sample was composed of 23 Caucasian Brazilian individuals of both genders, with mean age: 15.76 ± 1.75 years, presenting Class II division 1 malocclusion with mandibular deficiency and treated with Herbst appliance during a period of 8 months. Cone-beam computed tomography images were obtained before (T1) and after treatment (T2) to analyse and measure the structures: height and thickness of alveolar bone at the molar region and dental changes at vertical of the molars and crossectional direction (intermolar distance and inclination). The error of the method evaluated by the Intraclass Correlation Coefficient (ICC) and Paired t-tests were used to compare T1 and T2 with significance level of 5%. The results showed that the ICC was high for all measurements (0.95). There was increase in height (0.37 mm) and alveolar bone thickness only at the lingual region of the upper molars with more significant result at the middle third (0.45 mm) and apical region (0.58 mm). Regarding dental changes, there was a significant decrease at intermolar angulation mean of 4.6° (p<0.05). It was concluded that orthodontic treatment with Herbst appliance led to changes in height and alveolar bone thickness at the lingual and intermolar angulation in the upper arch. / Mestre
129

Avaliação cefalométrica das alterações esqueléticas, dentárias do perfil facial naturais e induzidas pelos aparelhos de Herbst e Bionator no tratamento da má oclusão de Classe II, divisão 1ª /

Nunes, Ingrid Madeira de Barros. January 2011 (has links)
Orientador: Dirceu Barnabé Raveli / Banca: Jorge Abrão / Banca: Kurt Faltin Jr. / Banca: Luiz Gonzaga Gandini Jr. / Banca: Ary dos Santos Pinto / Resumo: O objetivo deste estudo foi avaliar as alterações esqueléticas, dentárias e do perfil facial naturais e induzidas pelos aparelhos de Herbst e Bionator no tratamento da má oclusão de Classe II, divisão 1ª. Para tanto, se utilizou uma amostra de 90 telerradiografias laterais de 45 indivíduos no estágio prépubertário, subdivididos em dois grupos experimentais e um controle. O primeiro grupo, composto por 15 indivíduos brasileiros, com idade média inicial de 9,4 anos, foi tratado com o aparelho de Herbst por um período de 7 meses. O segundo grupo experimental, composto por 15 indivíduos brasileiros, leucodermas, com idade média inicial de 9,9 anos foi submetido a bionatorterapia por um período médio de 21 meses. O grupo controle de 15 indivíduos, não tratados ortodonticamente, provém do Burlington Growth Centre, Universidade de Toronto, Canadá. A comparação intragrupo foi realizada por meio do teste t de Student e a comparação intergrupos por meio da ANOVA complementada pelo teste de Bonferroni. Os resultados evidenciaram que ambas as terapias não influenciam o desenvolvimento da maxila, atuam de maneira favorável na mandíbula e na relação maxilomandibular, tendem a aumentar a altura facial ântero-inferior (AFAI) e altura facial posterior (AFP), em maior proporção nesta última, sendo o incremento estatisticamente significante apenas no grupo do Bionator. Apenas o grupo tratado pelo aparelho de Herbst mostrou alterações dentárias e do perfil facial significativas para as variáveis relação molar, sobressaliência e sobremordida, convexidade facial e protrusão do lábio inferior. / Abstract: The aim of this study was to evaluate the dental changes both natural and induced by Herbst' appliance and Bionator in the treatment of Class II, division 1 malocclusion. In order to do that, we used a sample of 90 lateral radiographs of 45 individuals in pre-pubertal stage, divided up into two experimental groups and one control. The first group, composed of 15 Brazilian individuals, with initial mean age of 9.4 years, was treated with the Herbst appliance for a period of seven months. The second experimental group consisting of 15 Brazilian individuals, initial mean age of 9.9 years has gone through bionatortherapy for an average period of 21 months. The control group of 15 individuals, who were not treated orthodontically, comes up from the Burlington Growth Centre, University of Toronto, Canada. The intragroup comparison was performed using the Student t test and intergroup comparisons by ANOVA complemented by the Bonferroni test. The results have shown that both therapies have no influence at all in the development of the jaw, acting favorably in the mandible as well as in the maxillomandibular relationship,toward increasing lower anterior facial height (LAFH) and posterior facial height (PFH), with greater proportion in the last one, bearing in mind, however, that the increase is statistically significant only in bionatorgroup. Only the group treated with the Herbst appliance presented significant dental and on facial profile changes in the variables :molar relationship,overjet, overbite, convexity and lower lip protrusion. / Doutor
130

Avaliação cefalométrica das alterações dentárias esqueléticas induzidas pelo uso do aparelho de Herbst no tratamento da má oclusão de classe II, divisão 1ª de Angle - Estudo longitudinal.

Dib, Luana Paz Sampaio. January 2007 (has links)
Orientador: Dirceu Barnabé Raveli / Banca: Gladys Cristina Dominguez Rodriguez / Banca: Ary dos Santos-Pinto / Resumo: Este estudo cefalométrico foi desenvolvido com o propósito de avaliar as alterações dentárias e esqueléticas naturais e induzidas pelo uso do aparelho de Herbst. O grupo experimental foi constituído por 15 indivíduos pré-pubertários, leucodermas, com idade média de 9,4 anos (+ ou - 06 meses), de ambos os gêneros, com má oclusão Classe II Divisão 1ª com deficiência mandibular. Foi utilizado para comparação um grupo controle de 15 indivíduos, leucodermas, com má oclusão Classe II Divisão 1ª, não tratados ortodonticamente, pareados quanto às idades óssea e cronológica do grupo experimental, derivados do Burlington Growth Centre, Departamento de Ortodontia da Faculdade de Odontologia, Universidade de Toronto, Canadá. Foram realizadas radiografias em norma lateral iniciais e após 7 meses de tratamento no grupo experimental e no grupo controle as radiografias foram tomadas aos 9 e 10 anos de idade. A análise estatística foi realizada por meio do teste t de Student, com nível de significância de 5%. De acordo com os dados obtidos, verificamos que o uso do aparelho de Herbst resultou numa restrição significativa do crescimento maxilar, enquanto que o efeito do crescimento natural havia sido de aumentar o comprimento da maxila; o crescimento mandibular foi estimulado em ambos os grupos, porém mais intenso no grupo tratado; houve aumento das alturas faciais anterior e posterior no grupo experimental, ao passo que no grupo controle a altura facial posterior não foi alterada; em relação à convexidade facial e a relação maxilo-mandibular houve uma alteração positiva no grupo tratado, enquanto no grupo não tratado elas se mantiveram estáveis; e, o plano mandibular não sofreu alteração em ambos os grupos. As alterações dentárias caracterizaram-se no grupo tratado pela verticalização dos incisivos superiores, distalização dos molares... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This cephalometric study was developed in order to evaluate natural dental and skeletal alterations as well as those induced by the use of Herbst's appliance. The experimental group consisted of 15 pre-pubertal individuals, white children, with mean age of 9.4 years (+ or - 06 months), both male and female, presenting Class II, 1st Division malocclusion and mandibular deficiency. A control group of 15 white children with Class II, 1st Division malocclusion, who were not treated orthodontically, was used for comparison, paired considering bone and chronological ages of the experimental group, originally from Burlington Growth Centre, Orthodontics Department of the University of Toronto Dental School, Canada. Initial and 7-month treatment follow-up radiographs were obtained in lateral take for the experimental group, and for the control group the radiographs were taken at 9 and 10 years of age. Statistical analysis was carried out with Student's test, at significance level of 5%. According to the data obtained, it was verified that the use of Herbst's appliance resulted in a significant restriction of the maxillary growth, while the effect of natural growth had been to increase maxilla length; mandibular growth was stimulated in both groups, however, it was more intense in the group treated; there was an increase in the anterior and posterior facial heights of the experimental group, whereas in the control group the posterior facial height was not altered; considering facial convexity and the maxilla-mandible relationship, there was a positive alteration in the group treated, while in the non-treated group they were kept stable; and, the mandibular plane suffered no alteration in any of the groups. In the treated group, dental alterations were characterized by the verticalization of the maxillary incisors, distal tipping of the maxillary molars, buccal tipping of the mandibular... (Complete abstract, click electronic access below) / Mestre

Page generated in 0.0516 seconds