Spelling suggestions: "subject:"aparelho""
141 |
Automação e controle da caixa de pressão negativa de membros inferioresCambraia, Rodrigo Reckziegel January 2014 (has links)
Made available in DSpace on 2014-08-22T02:01:12Z (GMT). No. of bitstreams: 1
000460448-Texto+Completo-0.pdf: 5951570 bytes, checksum: afed14c2ca9f2963cc42ed8d5fb7baaa (MD5)
Previous issue date: 2014 / The use of equipment "lower body negative pressure box" (LBNP) is a instrument of great importance to the scientific community health sciences. Initially used for simulation of orthostatic stress in space agencies studies on the physiological performance, today it has a range of applications to be study. In mid-2002, a LBNP Box was developed at the Center for Microgravity Laboratory, but it became outdate and out of use. This work was done to modernize pneumatic, electrical, electronic systems and the application interface. The realized retrofit enables the equipment for research use in the area of Aerospace Medicine on orthostatic intolerance of the cardiovascular system. Auniversal process controller with PID control technique was used with a classical tuning control proposed in the first method of Ziegler and Nichols. / O uso do equipamento “lowerbody negative pressureBox” (LBNP- caixa de pressão negativa) é de grande importância para a comunidade científica das ciências da saúde. Inicialmente utilizado para simulação de estresse ortostático em estudos sobre o comportamento fisiológico pelas agências espaciais, hoje já tem sua gama de aplicações para estudo. Em meados de 2002 uma LBNP foi desenvolvida no Laboratório do Centro de Microgravidade, porém ela ficou desatualizada e inoperante. O presente foi realizado para modernizar ossistemas pneumático, elétrico, eletrônico assim como o aplicativo de interface. O “retrofit” realizado deixou o equipamento em condições para o uso em pesquisas na área de Medicina Aeroespacial sobre intolerância ortostática do sistema cardiovascular. Um controlador universal de processos com controle do tipo PID utilizando técnica de controle clássico de sintonia proposto no primeiro método de Ziegler e Nichols.
|
142 |
Desenvolvimento de uma plataforma virtual em telecirurgia como ferramenta complementar de ensinoCardoso, Ricardo Bertoglio January 2014 (has links)
Made available in DSpace on 2014-11-18T01:01:19Z (GMT). No. of bitstreams: 1
000462672-Texto+Completo-0.pdf: 8146289 bytes, checksum: b06948bf980943025484977e7b5c207b (MD5)
Previous issue date: 2014 / The constant evolution of technology enables a wider access to and a more global production of digital texts, audios, images, and videos. The internet, which greatly enhances this sharing capability, has been constantly growing in coverage and in data transfer capacity, therefore allowing virtual communication to simulate real-life interaction. The combination of these elements in education, especially in health education, led to large improvements in the capacity to illustrate it rather than just explain it. These technologies have great potential to improve teaching methods, which sometimes are inefficient or have high maintenance costs. In the theoretical learning of surgical procedures, for example, the presence of students in the operating room does not necessarily provide them with a better understanding of the technique used by the surgeon, as he or she may not be able to get close enough to see the area where the procedure is being performed. This problem stems from the limited space available in the room, as well as from the care for the patient’s wellbeing, which should not be compromised as result of the amount of observers in the room. Aware of these elements and of the existing demand for improvement of teaching tools in the university, this project had as its main aim the development of a telesurgery system for health education. In order to accomplish this goal, three systems were developed: a photograph camera positioning equipment (eSurg-Arm) to assist image acquisition in the operating room; a specification of equipment and video formats to enable image acquisition and transmission (eSurg-Video), and a health education web platform (eSurg-Web). The eSurg-Arm successfully developed the design, the simulation, the prototyping, and the testing of hardware, software, and mechanical devices and parts. The development of eSurg-Video called for the analysis of different video compression and transmission technologies. The making of eSurg-Web established the parameters (i. e. functionalities and information) to build a distance education web-learning tool, as well as to develop a functional prototype. Each of these systems accomplished different results. The eSurg-Arm built and validated three systems: movement control and instrumentation, articulated arm and Pan/Tilt/Roll/Zoom. The eSurg-Video enabled the synchronous and asynchronous video streaming of different resolution videos. The eSurg-Web accomplished the design of multiple information blocks, which enabled the development of an educational web platform. In short, the eSurg project successfully positioned an image acquisition system and granted access to a web platform that allow professors and students to interact with surgical multimedia content from medical/chirurgical procedures performed at the São Lucas Hospital – PUCRS. / A constante evolução da tecnologia vem permitindo um acesso cada vez mais amplo e uma produção cada vez mais global de textos, áudios, imagens e vídeos. A Internet cresce constantemente em alcance e capacidade de transferência de dados, tornando possível a comunicação virtual em um nível que já imita a realidade. A combinação desses elementos na educação, e mais especificamente na educação em saúde, tem resultado em grandes avanços na capacidade de professores de ilustrar o conteúdo ao invés de apenas explica-lo. Dessa forma, essas ferramentas vêm ao encontro da necessidade de melhoria de métodos de ensino, muitas vezes pouco eficientes e de custo elevado para sua implementação e manutenção. No aprendizado teórico sobre técnicas cirúrgicas, por exemplo, a presença de acadêmicos junto ao paciente não garante a visualização do procedimento, devido ao espaço limitado e à importância de que a quantidade de observadores não prejudique o decorrer da cirurgia. Atento a esses diferentes elementos e às demandas existentes na universidade, esse projeto teve como objetivo o desenvolvimento de um sistema de Telecirurgia como ferramenta educacional em saúde. Para tanto, foram desenvolvidos: um equipamento para posicionamento de um sistema de aquisição de imagens em sala cirúrgica (eSurg-Arm); uma especificação de equipamentos e formatos para aquisição e transmissão de imagens (eSurg-Video); e uma aplicação web em linguagem de alto nível como ferramenta educacional em saúde (eSurg-Web). O eSurg-Arm contemplou o design, a simulação, a prototipação e a realização de ensaios de hardware, software e de mecanismos e peças mecânicas. O eSurg-Video foi responsável por analisar diferentes tecnologias de compressão e transmissão de vídeo. O eSurg-Web realizou a definição das funcionalidades e informações necessárias para a criação de uma plataforma web para ensino a distância, tendo feito sua prototipação. Cada uma das etapas de desenvolvimento obteve resultados específicos. O eSurg-Arm resultou na construção e validação de três sistemas, o primeiro de controle e instrumentação de movimento, o segundo de suporte articulado e o terceiro de Pan/Tilt/Roll/Zoom. O eSurg-Video resultou na capacidade de oferecer diferentes resoluções de vídeo, bem como transmiti-los de forma síncrona ou assíncrona. O eSurg-Web teve como resultado o design de múltiplos conjuntos de informações que permitiu a prototipação de uma aplicação web. O eSurg teve sucesso em permitir o posicionamento de sistema de aquisição de imagens, por meio do eSurg-Arm, e em desenvolver uma ferramenta educacional em saúde, que possibilita o acesso interativo de docentes e discentes ao conteúdo de cirurgias realizadas no Hospital São Lucas da PUCRS. O sistema de aquisição e transmissão de vídeos definido pelo projeto se mostrou adequado à prática cirúrgica nos ensaios e testes realizados.
|
143 |
Estudo da estratégia de harmonização da quantificação do SUV em imagens de PET/CTFischer, Andréia Caroline Fischer da Silveira January 2014 (has links)
Made available in DSpace on 2014-12-06T01:01:32Z (GMT). No. of bitstreams: 1
000462943-Texto+Completo-0.pdf: 4086036 bytes, checksum: 8b6abefa3b76b3bc43dbf4ca084a593b (MD5)
Previous issue date: 2014 / In clinical practice, PET/CT images are often analyzed qualitatively by visual comparison of tumor lesions and normal tissues uptake; and semi-quantitatively by means of a parameter called SUV (Standardized Uptake Value). To ensure that longitudinal studies acquired on different scanners are interchangeable, and information of quantification is comparable, it is necessary to establish a strategy to harmonize the quantification of SUV. The aim of this study is to evaluate the strategy to harmonize the quantification of PET/CT images, performed with different scanner models and manufacturers. For this purpose, a survey of the technical characteristics of equipment and acquisition protocols of clinical images of different services of PET/CT in the state of Rio Grande do Sul was conducted. For each scanner, the accuracy of SUV quantification, and the Recovery Coefficient (RC) curves were determined, using the reconstruction parameters clinically relevant and available. From these data, harmonized performance specifications among the evaluated scanners were identified, as well as the algorithm that produces, for each one, the most accurate quantification. Finally, the most appropriate reconstruction parameters to harmonize the SUV quantification in each scanner, either regionally or internationally were identified. It was found that the RC values of the analyzed scanners proved to be overestimated by up to 38%, particularly for objects larger than 17mm. These results demonstrate the need for further optimization, through the reconstruction parameters modification, and even the change of the reconstruction algorithm used in each scanner. It was observed that there is a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies. Thus, the choice of reconstruction method should be tied to the purpose of the PET/CT study in question, since the same reconstruction algorithm is not adequate, in one scanner, for qualitative and quantitative assessments in different scopes. We concluded that the harmonization strategy of the SUV quantification presented in this paper was effective in reducing the variability of small structures quantification. However, for the comparison of SUV quantification between different scanners and institutions, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation is maintained, in order to minimize the SUV variability due to biological factors. / Na rotina clínica, imagens de PET/CT, costumam ser analisadas qualitativamente, mediante a comparação visual entre a captação nos tecidos hipercaptantes e nos tecidos normais; e, semiquantitativamente, por meio de um parâmetro denominado SUV (do inglês Standardized Uptake Value). Para garantir que estudos longitudinais adquiridos em distintos equipamentos sejam intercambiáveis e informações de quantificação sejam comparáveis, torna-se necessário o estabelecimento de uma estratégia de harmonização da quantificação do SUV. O objetivo geral deste estudo é avaliar uma estratégia de harmonização da quantificação de imagens de PET/CT, realizada com equipamentos de diferentes modelos e fabricantes. Para tanto, foi realizado um levantamento das características técnicas do equipamento e dos protocolos de aquisição das imagens clínicas de distintos serviços de PET/CT do estado do Rio Grande do Sul. Para cada equipamento, foram determinadas a acurácia da quantificação do SUV e as curvas de Coeficiente de Recuperação (RC, do inglês Recovery Coefficient), utilizando os parâmetros de reconstrução clinicamente disponíveis e relevantes. A partir desses dados, foram identificadas as especificações de desempenho harmonizáveis dentre os equipamentos avaliados, assim como o algoritmo que produz, em cada equipamento, a quantificação mais acurada. Finalmente, foram identificados os parâmetros de reconstrução mais adequados à harmonização da quantificação do SUV em cada equipamento, em âmbito regional e internacional. Constatou-se que os valores de RC dos equipamentos analisados mostraram-se superestimados em até 38%, particularmente para objetos de dimensões maiores do que 17 mm. Estes resultados mostram a necessidade de uma otimização, mediante a modificação dos parâmetros de reconstrução utilizados e até mesmo da mudança do algoritmo de reconstrução utilizado em cada equipamento. Observou-se que existe uma dissociação entre a melhor imagem para análise qualitativa e a melhor imagem para quantificação dos estudos de PET/CT. Assim, a escolha do método de reconstrução deve estar atrelada à finalidade do estudo de PET/CT em questão, visto que um mesmo algoritmo de reconstrução não se mostra adequado, em um único equipamento, às avaliações qualitativas e quantitativas, em diferentes âmbitos. Conclui-se que a estratégia de harmonização da quantificação do SUV apresentada neste trabalho mostrou-se eficaz na redução da variabilidade da quantificação de pequenas estruturas. Entretanto, para que a quantificação do SUV possa ser comparada entre diferentes equipamentos e instituições, é fundamental que, além da harmonização da quantificação, seja mantida a padronização da metodologia de preparo do paciente, visando minimizar a variabilidade atribuída ao SUV decorrente de fatores biológicos.
|
144 |
Influência dos fotoativadores LED e PAC na colagem de bráquetes metálicos em superfícies de cerâmicaBaumgarten, Ana Maria dos Santos January 2007 (has links)
Made available in DSpace on 2011-12-27T14:13:59Z (GMT). No. of bitstreams: 2
000400702-0.pdf: 4756004 bytes, checksum: c5c3ca2a6525c80088d7d0621017322d (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate and compare by means of shear bond strength test, the performance of bracket bonding on porcelain, using different kinds of curing-light (Ortholux ™ LED and Apollo 95E®), with different polymerization times. 90 ceramic discs were divided into six groups according to the source of light and exposure time. For LED groups, 10, 15 and 20 seconds were applied while for PAC groups 4, 6 and 9 seconds. After 24 hours of distilled water at 37°C storage, samples were submitted to the shear bond strength test using a universal testing machine (Emic DL 2000®) with a crosshead speed of 0,5 mm/min. According to the ANOVA and Tukey tests, there were statiscal differences between the groups (p<0,05). There was no statistical difference between LED groups when compared to PAC 6s and 9s groups. The 4s PAC group showed lower average shear bond strength when compared to the other groups, therefore this exposure time should be not indicated for bracket bonding on ceramic surfaces. According to Kruskal-Wallis test, there was statistical difference on the Adhesive Remnant Index (ARI) scores’ distribution between the groups (p<0,05). The groups LED 20s, PAC 6s and PAC 9s predominantly showed 0 index. On the other hand, the groups LED 10s and PAC 4s showed mainly score 3. The LED 20s group showed a major incidence of fractures on the porcelain surface (53,3%). Generally the most frequent ARI index obtained was 3 (36,7%) followed by index 0 (35,6%), with no statistical difference between them. These results suggest that high intensity light sources such as Ortholux ™ LED and Apollo 95E® are effective on the polymerization of Transbond XT®, reducing the curing time necessary for bonding of metallic brackets on porcelain surfaces. / O objetivo do presente estudo foi avaliar e comparar, por meio do teste de resistência ao cisalhamento, a colagem de bráquetes em superfícies de cerâmica expostos a duas fontes luminosas (Ortholux™ LED e o Apollo® 95E), mediante diferentes tempos de exposição. Noventa discos de cerâmica foram divididos em seis grupos de acordo com a fonte de luz e o tempo de exposição utilizado. Para os grupos fotoativados com o LED foram usados os tempos de 10, 15 e 20 segundos e para os grupos polimerizados com o PAC, 4, 6 e 9 segundos. Após 24h de armazenamento em água destilada a 37°C, os corpos-de-prova foram submetidos ao teste de cisalhamento por meio da máquina de ensaio universal (Emic DL 2000®), numa velocidade de carregamento de 0,5 mm/min. De acordo com os testes estatísticos ANOVA e Tukey, houve diferença significativa entre os grupos estudados (p<0,05). Houve equivalência estatística das médias de resistência de união dos grupos LED (10s, 15s e 20s) com os correspondentes grupos PAC (6s e 9s). O grupo PAC 4s apresentou média inferior aos demais grupos, não sendo indicado para colagem ortodôntica em cerâmica. Segundo o teste Kruskal-Wallis, houve diferença significativa na distribuição dos escores do Índice Adesivo Remanescente (IAR) entre os grupos (p<0,05). Os grupos LED 20s, PAC 6s e PAC 9s apresentaram predominantemente índice 0. Comportamento oposto foi observado nos grupos LED 10s e PAC 4s, onde o escore 3 prevaleceu. O grupo LED 20s demonstrou a maior incidência de fraturas da cerâmica (53,3%). De modo geral, o tipo de descolagem mais freqüente foi o escore 3 do IAR, ocorrendo em 36,7% da amostra seguidos do escore 0 (35,6%), do qual não diferiu estatisticamente. Os resultados obtidos na presente pesquisa sugerem que as fontes luminosas de alta intensidade como o Ortholux™ LED e o Apollo® 95E são eficazes na fotoativação da resina composta Transbond XT®, reduzindo o tempo necessário de polimerização durante a colagem de bráquetes metálicos em superfícies de cerâmica.
|
145 |
Retração de caninos superiores com bráquetes autoligados e convencionaisMezomo, Maurício Barbieri January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2
000414875-0.pdf: 8343665 bytes, checksum: eca6520ad66453c0339e6ec79200478b (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this split mouth randomized clinical trial was to evaluate and compare the space closure during the retraction of upper permanent canine with self-ligating "SmartClip" and conventional "Gemini" brackets. Sample complied 13 patients with Class I biprotrusion or Class II 1st division malocclusion, with an average age of 18 years and 4 months, 3 male and 10 female. All were submitted to the therapeutic extraction of two first premolars. The retraction of the upper canines was performed with elastomeric chain with 150g of force. The evaluations were performed at four times (T1 – initial, T2 – 4 weeks, T3 – 8 weeks, T4 – 12 weeks) in stone model casts. The amount of movement and the rotation of the canines as well anchorage loss of upper first molars were evaluated. The space closure measurement was made between canine and second premolar and rotation was assessed by an angle formed by the intersection of the line drawn through the canine’s contact points and the line of the palatal suture. The anchorage loss was measured by a guide adapted at the palatal rugae in stone casts at initial and end.The data obtained were subjected to Student t test considering level of significance of 5%. The results shown that selfligating bracket had an average of 0. 92 mm (+/- 0. 29) of rate movement and 8. 46o (+/- 4. 68) of the rotation of the upper canines and 0. 65 mm (+/- 0. 24) of anchorage loss; the conventional bracket had an average of 0. 84 mm (+/- 0. 22) of rate movement and 11. 77o (+/- 3. 26) of the rotation of and the upper canines and 0. 57 mm (+/- 0. 24) of anchorage loss. There was no difference (p=0. 250) in the rate of movement of the canines between the two types de brackets. The rotational control of the canines was better promoted by self-ligating bracket (p=0. 005). There was anchorage loss for both groups, with no statistical difference between them (p=0. 157). / O objetivo deste ensaio clínico randomizado tipo boca dividida foi avaliar e comparar o fechamento dos espaços durante a retração dos caninos permanentes superiores com os bráquetes autoligado “SmartClip” e convencional “Gemini”. A amostra foi constituída de 13 pacientes portadores de maloclusão de Classe I com biprotrusão ou Classe II 1ª divisão de Angle, com média de idade de 18 anos e 4 meses, sendo 3 do gênero masculino e 10 do feminino. Todos os indivíduos foram submetidos à extração terapêutica dos primeiros pré-molares superiores. A retração dos caninos foi realizada através de cadeia elastomérica com força de 150g. As avaliações foram realizadas nos tempos (T1 – inicial, T2 – 4 semanas, T3 – 8 semanas, T4 – 12 semanas) através de modelos de gesso. Foram analisadas a taxa da movimentação e rotação dos caninos bem como a perda de ancoragem dos primeiros molares permanentes superiores. A mensuração do fechamento dos espaços foi realizada entre o canino e o segundo pré-molar e a rotação através do ângulo formado pela intersecção da linha que passava pelos pontos de contato dos caninos com a linha da rafe palatina mediana. A perda de ancoragem foi medida por um guia adaptado às rugas palatinas nos modelos de gesso inicial e final. Os dados obtidos foram submetidos a análise estatística através do teste t-Student considerando o nível de significância de 5%. Os resultados demonstraram que o bráquete autoligado apresentou taxa média de movimentação mensal de 0,92mm (+/- 0,29) e rotação de 8,46o (+/- 4,68) dos caninos superiores e a perda de ancoragem de 0,65mm (+/- 0,24); o bráquete convencional apresentou taxa média de movimentação mensal de 0,84mm (+/- 0,22) e rotação de 11,77o (+/- 3,26) dos caninos superiores e a perda de ancoragem de 0,57mm (+/- 0,24).Não houve diferença significativa (p=0,250) entre a taxa de movimentação dentária dos caninos entre os dois tipos de bráquetes. O controle de rotação dos caninos foi melhor promovido pelo bráquete autoligado (p=0,005). Ocorreu perda de ancoragem para ambos os grupos, sem diferença estatística entre eles (p=0,157).
|
146 |
Comportamento da mandíbula decorrente do tratamento da maloclusão de classe II com aparelho extrabucal de tração cervical e tração combinadaCardoso, Mauro Rogério Monteiro January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:17Z (GMT). No. of bitstreams: 2
000422970-0.pdf: 1054472 bytes, checksum: 74fe5716b4592896f0ca08a19b8b378d (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was evaluate and compare the effects of the cervical and combined headgear over the mandible and the maxillomandibular relationship. Sixty-two patients treated in the Orthodontic clinic of the Pontifícia Universidade Católica do Rio Grande do Sul were selected. Then, they were assigned into three groups: the Group 1 was composed by 22 patients with Class II malocclusion treated by cervical headgear; Group 2 was composed by 20 patients treated by combined headgear and both experimental groups were treated until when the class I molar be reached; Group 3 (control) was composed with 20 patients with class I molar relationship and they were treated only by minor preventive procedures in the lower arch. Initial (T1) and follow-up (T2) lateral cephalograms of each patient were used, which were traced and the points were digitalized to the analyses. For the statistics tests, the analysis of variance complemented by Tukey’s test was used to compare initial measurements (T1) of all groups and for the comparison between means differences (T2-T1) among the three groups. Student’s t test was used for the comparison between T1 and T2 in each group. Significant level was set at 5%.The results showed that there was significant mandibular growth for the three groups (p < 0,05). The Group 1 showed significant increase in Y axis and SN. GoGn with the treatment (p < 0,05). The Group 2 did not show significant increase in Y axis and SN. GoGn (p > 0,05). There was reduction in facial convexity for both experimental groups with more intensity for the Group 1, however, without significant difference (p > 0,05). Therefore, based on these results it is possible conclude that there is clockwise rotation of the mandible only in treatment with cervical headgear and there is facial convexity reduction in both treatments. / O objetivo deste estudo foi avaliar e comparar os efeitos dos aparelhos extrabucais (AEB) de tração cervical e tração combinada sobre a mandíbula e a relação maxilo-mandibular. Para tanto, foram selecionados 62 pacientes tratados na Clínica de Ortodontia da Faculdade de Odontologia da Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS). Os pacientes foram, então, divididos em três grupos: o Grupo 1 foi formado por 22 pacientes portadores de maloclusão de Classe II, tratados com AEB de tração cervical; o Grupo 2 foi formado por 20 pacientes portadores da maloclusão de Classe II e tratados com AEB de tração combinada, sendo que ambos os grupos experimentais foram tratados até a obtenção de relação molar de Classe I; o Grupo 3 (controle) foi formado por 20 pacientes com relação molar de Classe I e tratados somente com pequenos procedimentos preventivos no arco inferior. Utilizaram-se as telerradiografias inicial (T1) e de reestudo (T2) de cada paciente, as quais foram traçadas e os pontos foram digitalizados para as análises. Para a análise estatística, foi utilizada análise de variância (ANOVA) complementada pelo teste de Tukey para a comparação inicial entre os grupos e para a comparação das diferenças médias entre T1 e T2 de todos os grupos. Para a comparação entre T1 e T2 de cada grupo, foi utilizado o teste t-student e para ambos os testes foi determinado o nível de significância máximo de 5%. Os resultados demonstraram que houve crescimento mandibular significativo para todos os grupos (p < 0,05). O Grupo 1 apresentou aumento significativo no eixo y e SN. GoGn com o tratamento (p < 0,05). O Grupo 2 não apresentou aumento significativo no eixo y e SN. GoGn (p > 0,05). Houve redução de convexidade para ambos os grupos experimentais, com mais intensidade no Grupo 1, no entanto, sem diferença significativa (p > 0,05).Com base nestes resultados, é possível concluir que há rotação horária da mandíbula somente no tratamento com AEB cervical e que ambos os tratamentos promovem a redução de convexidade facial.
|
147 |
Alterações dentoesqueléticas decorrentes do tratamento da classe II divisão 1 com aparelhos tipo Haas modificado e extrabucal de tração altaCamargo, Clécio Kopczynski January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:31Z (GMT). No. of bitstreams: 2
000433434-0.pdf: 3002918 bytes, checksum: eb035bf3c957cc6056e46a30fdf76f17 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the dento-skeletal effects of the headgear (HG) high traction used after rapid maxillary expansion (RME). The total sample comprised 43 Brazilian individuals between entre 9 and 13 years old. The experimental group had twenty three individuals (mean age 11 ± 1,6 years old) with Class II division 1 malocclusion treated by RME and HG high traction (OrthoCap and conventional cap) applied after 8 days of expansion. The control group included 20 individuals with Class I malocclusion which was not treated during the period of the study. All individuals had two telerradiographies: initial (T1) and progress (T2), which was taken after 6 months of observation. Cephalometric points were digitalized into Dentofacial Planner Plus software to obtain the cephalometric measurements. In the statistical analysis Student’s t test was used to compare values of T1 and T2 in each group and for comparison of the differences (T1-T2) between groups. Results showed that treatment with RME and HG high traction provoked restriction of forward growth of the maxilla (p<0. 001) and clockwise rotation of the maxilla (p<0. 05). Maxillo-mandibular relationship was improved although there was a clockwise rotation of the mandible (p<0. 05). Superior molars moved toward distal with distal inclination and intrusion (p<0. 001). Superior incisors were retroclined (p<0. 05). Therapy rapidly expanding maxillary extraoral traction was very high effective in treating patients with Class II malocclusion. / No presente estudo avaliaram-se cefalometricamente os efeitos dentoesqueléticos do aparelho extrabucal (AEB) de tração alta com expansão rápida maxilar (ERM) prévia. Para tanto, foram avaliados 43 indivíduos brasileiros brancos e saudáveis, com idades entre 9 e 13 anos. O Grupo Experimental foi composto por 23 pacientes (idade média 11 ± 1,6 anos) com maloclusão de Classe II divisão 1, tratados com ERM e AEB de tração alta (OrthoCap e casquete tradicional) a partir do oitavo dia de ERM. O Grupo Controle foi composto por 20 pacientes com maloclusão de Classe I que não receberam tratamento ortodôntico durante o período de avaliação. Todos indivíduos apresentavam telerradiografias de perfil ao início (T1) e após 6 meses (T2), em média. Pontos cefalométricos foram digitalizados no programa Dentofacial Planner Plus para obtenção das medidas cefalométricas. Na análise estatística foi utilizado o teste t de Student para comparação entre os valores de T1 e T2 dentro de cada grupo e para comparação das diferenças (T1-T2) entre os grupos. Os resultados demonstraram que o tratamento com ERM e AEB de tração alta provocou restrição do crescimento maxilar para anterior (p<0,001) e rotação maxilar no sentido horário (p<0,05). Ocorreu melhora na relação maxilo-mandibular, apesar da rotação da mandíbula no sentido horário (p<0,05). Os molares superiores apresentaram movimento distal, com inclinação distal e intrusão (p<0,001).Nos incisivos superiores ocorreu verticalização e deslocamento posterior (p<0,05). A terapia de expansão rápida maxilar com extrabucal de tração alta mostrou-se muito eficaz no tratamento de pacientes portadores de maloclusão de classe II.
|
148 |
Efeito do tempo de polimeração na colagem de bráquetes com o uso dos fotoativadores LED e PACDall'igna, Carine Maccarini January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:37Z (GMT). No. of bitstreams: 2
000397727-0.pdf: 6814018 bytes, checksum: 6e35a618cab019880f495b514a8897a3 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The purpose of this study was to evaluate and compare the bonding resistance to the shear bond strength of brackets bonded by two light curing units, LED and PAC, with different exposure times. Ninety deciduous incisor bovine teeth were divided into 6 groups, according to the curing light and exposure times used. In the LED group specimens were exposed to photoactivation for 5, 10 and 15 seconds. In the PAC group they were exposed to 3, 6 and 9 seconds of photoactivation. In order to check the LED (OrtholuxTM LED Curing Light, 3M Unitek, EUA) and PAC (Apollo® 95E, DenMed Technologies, EUA) light curing units, a specific radiometer for each unit was utilized, whose irradiance mean values were 830mW/cm2 and 1800mW/cm2, respectively. Brackets were bonded with TransbondTM XT®, and the enamel surfaces were prepared following the manufacturer’s instructions. After the brackets were bonded they were stored in distilled water at 37°C for 24 hours. They were then subjected to a shear force, in an inciso-gingival direction, at a crosshead speed of 0,5mm/min with a Emic DL2000® testing machine. According to ANOVA and Tukey tests, a significant difference in mean shear bond strength was detected among the study groups (p<0. 001).The LED photoactivated groups did not show statistical significant difference between them. The photoactivated group of 15s (16,68MPa) presented the highest range of bonding resistance, followed by the 10s group (14,76MPa), and than by the 5s group (13,92MPa). In regards to the PAC photoactivation, the 9s (12,66MPa) and 6s groups (9,96MPa) did not show statistical difference between them. The lowest range of shear bond strength was obtained by the PAC 3s group (8,29MPa), but when compared to the PAC 6s group, there was no statistical difference. It was observed that even though the groups that presented the lowest ranges of bonding resistance, LED 5s and PAC 3s, their values were still enough to support the strength applied by either orthodontic forces or forces of mastication.The Kruskal-Wallis analysis of the adhesive remmant index (ARI) scores indicated that there was no significant difference of bond failure sites between the study groups. The predominant ARI score was 3 (65,6%), which showed that the composite was kept adhered on the enamel, preventing it from trauma. The results conclude that either the LED or PAC technique can be used for bonding brackets effectively. The LED and PAC curing lights permit a significant reduction of time in the orthodontic bonding process compared to the traditional technique with halogen lamps. / O presente estudo objetivou avaliar e comparar a resistência de união ao cisalhamento de bráquetes colados com dois sistemas de fotoativação de resinas compostas, o LED e o PAC, mediante diferentes tempos de exposição. Foram selecionados 90 dentes incisivos decíduos bovinos, os quais foram divididos em seis grupos, de acordo com a fonte de luz e o tempo de exposição utilizado. No grupo LED, foram usados os tempos 5, 10 e 15 segundos e, no grupo PAC, 3, 6 e 9 segundos. Para aferir a potência da luz emitida pelos aparelhos LED (OrtholuxTM LED Curing Light, 3M Unitek, EUA) e PAC (Apollo® 95E, DenMed Technologies, EUA), foi utilizado um radiômetro para cada natureza de luz, os quais indicaram como valores médios 800mW/cm2 e 1800mW/cm2, respectivamente. O sistema adesivo utilizado para a colagem dos bráquetes foi o TransbondTM XT®, e as superfícies de esmalte foram preparadas conforme as recomendações do fabricante. Após a colagem, os corpos-de-prova foram mantidos em água destilada a 37°C por 24 horas e submetidos à tensão de cisalhamento na máquina de ensaio mecânico Emic DL2000®, no sentido inciso-cervical, à velocidade de 0,5mm/min. De acordo com as análises estatísticas ANOVA e Tukey, verificou-se que houve diferença significativa entre os grupos estudados (p<0,005).Os grupos fotoativados por LED não mostraram diferença estatisticamente significativa entre si, sendo que o grupo fotoativado por 15s (16,68MPa) apresentou a maior média de resistência de união, seguido pelo grupo fotoativado por 10s (14,76MPa) e por 5s (13,92MPa). Quanto aos fotopolimerizados por PAC, os grupos fotoativados por 9s (12,66MPa) e por 6s (9,96 MPa) não mostraram diferença estatisticamente significativa entre si. A menor média de resistência de união foi obtida com o grupo fotopolimerizado por PAC durante 3s (8,29MPa), embora este grupo não tenha se diferenciado estatisticamente do grupo fotoativado por PAC por 6s. Observou-se que, mesmo nos grupos que apresentaram as menores médias de resistência de união, LED 5s e PAC 3s, os valores são considerados suficientes para suportar as forças exercidas, tanto pela mecânica ortodôntica quanto pela mastigação. De acordo com o teste estatístico Kruskal-Wallis, não houve diferença significativa no padrão de falhas na descolagem entre os grupos estudados. O escore predominante foi o número 3 (65,6%) do índice de adesivo remanescente (IAR) mostrando que a resina composta, predominantemente, permaneceu aderida à superfície do esmalte, preservando-o de eventuais traumas. Estes resultados permitem concluir que, tanto a tecnologia LED quanto a tecnologia PAC podem ser utilizadas na colagem de bráquetes com efetividade, permitindo redução significativa no tempo da colagem ortodôntica, comparada à tecnologia tradicional por lâmpadas halógenas.
|
149 |
Avaliação da quantificação em SPECT cardíaco utilizando mapas de atenuação com borramento tipo gaussianoSilva, Maria Teresa Santos da January 2007 (has links)
Made available in DSpace on 2013-08-07T18:52:56Z (GMT). No. of bitstreams: 1
000396639-Texto+Completo-0.pdf: 3477259 bytes, checksum: bb4eed136036815958a125e375927b8d (MD5)
Previous issue date: 2007 / Monte Carlo simulations have been used to validate attenuation and scattering correction methods for SPECT. The combination of a NCAT phantom, which incorporates respiratory movements and heartbeats, with the simulation process allows for a more adequate and realistic modeling of nuclear medicine data. The present work aimed at assessing the influence of the spatial resolution of attenuation coefficient maps in quantitative cardiac SPECT reconstruction. The study was based on several Monte Carlo simulations of SPECT images, with a special emphasis on NCAT 4D phantom (4D NURBS-based Cardiac Torso). It evaluated the effect of spatial resolution variation of non-uniform attenuation maps used in attenuation correction. The visual analysis of simulated reconstructed images revealed that the lack of attenuation correction produced dispersion of uptakes around myocardium and liver regions. In images corrected for attenuation, this blurring effect was replaced with the uniform activity on myocardial walls, both for the anterior and posterior walls. An increased quantitative and qualitative contrast was also observed with the application of attenuation correction. The main degrading factor in the diagnosis of myocardial perfusion in SPECT was the presence of attenuating tissue surrounding the heart, particularly near the liver. The application of the attenuation correction method in myocardial perfusion images in SPECT was significant to improve the quality of reconstructed images. The results of image profiles showed that, even with the occurrence of severe blurring in the attenuation maps, there was no significant change in the quantification of the myocardial walls, either in intensity or in contrast between the walls and the cavity. The use of low spatial resolution attenuation maps for attenuation correction did not cause the appearance of artifacts and high frequency objects, resulting in a smoother reconstructed image. / As simulações de Monte Carlo vêm sendo utilizadas para validar métodos de correção de atenuação e espalhamento em SPECT. O acoplamento à simulação de um phantom matemático como o NCAT, com movimentos respiratórios e batimentos cardíacos, permite uma modelagem ainda mais adequada e realista das aquisições em Medicina Nuclear. Este trabalho busca avaliar a influência da resolução espacial dos mapas de coeficientes de atenuação na reconstrução quantitativa em SPECT cardíaco. O estudo baseia-se em diversas simulações de Monte Carlo de imagens de SPECT, com ênfase especial no phantom matemático NCAT 4D (4D NURBSbased Cardiac Torso) e avalia o efeito da variação da resolução espacial dos mapas de atenuação não-uniformes utilizados na correção de atenuação. A análise visual das imagens simuladas reconstruídas revelou que a falta de correção de atenuação criou uma dispersão das contagens ao redor do miocárdio e do fígado. Nas imagens corrigidas para a atenuação, esse efeito de borramento foi substituído pela uniformização da atividade nas paredes do miocárdio, tanto na parede anterior como da parede posterior. Observou-se também um aumento de contraste quantitativo e qualitativo com a aplicação da correção de atenuação. O principal fator degradador do diagnóstico de perfusão miocárdica em SPECT foi a presença de tecido atenuador ao redor e nas proximidades do coração, particularmente próximo ao fígado. A aplicação do método de correção de atenuação nas imagens de perfusão miocárdica em SPECT revelou-se significante para a melhoria da qualidade das imagens reconstruídas. Os resultados dos perfis de contagem mostram que, mesmo do caso de borramento severo dos mapas de coeficiente de atenuação, não existe mudança significativa na quantificação das paredes do miocárdio, tanto com relação à intensidade quanto ao contraste entre as paredes e a cavidade. Observa-se também que a utilização dos mapas de atenuação de baixa resolução espacial na correção não provoca o surgimento de artefatos e de componentes de alta freqüência, suavizando a imagem reconstruída.
|
150 |
Estudo e desenvolvimento de algoritmos para o reconhecimento de arritmias cardíacasScolari, Diogo January 2007 (has links)
Made available in DSpace on 2013-08-07T18:53:04Z (GMT). No. of bitstreams: 1
000396423-Texto+Completo-0.pdf: 3058753 bytes, checksum: a4035eb0df593d854258c168ae594b28 (MD5)
Previous issue date: 2007 / The purpose of this work is studying the algorithms that can recognize cardiac arrhythmias. In this sense, a detailed analysis of two algorithms was made: HMM (Hidden Markov Model) and RBF (Radial Basis Function) artificial neural network, with the aim of recognizing three arrhythmias and the regular rhythm. The arrhythmias used for this research are: Atrial Fibrillation, Ventricular Tachycardia and Ventricular Fibrillation. They were selected by the following reasons: due to the need for immediate eletric defibrillation in Ventricular Tachycardia and Ventricular Fibrillation, and to the fact that the Atrial Fibrillation is the most incident in the world's population. The need for recognition of arrhythmias can be seen in AED (Automatic External Defibrillator) equipments, which is utilized to recognize and reverse the cardiac arrest in areas outside the hospitals environments. These pieces of equipment are being increasingly utilized by many countries, as an atempt to diminish mortality rates. Firstly, the heart was studied theoretically and the characteristics of each arrhythmia were analysed, in order to identify them. Secondly, pacients were selected in the biological signal database, PhsysioNet, for collecting data. After that, the results were generated by the comparison between the algorithms and their precisions. Finally, it was possible to confirm that both algorithms present good performance in the recognition of cardiac arrhythmias and was possible to reveal performance characteristics of both systems that corroborate the purpose of this work. / O presente trabalho tem por objetivo o estudo de algoritmos para o reconhecimento de arritmias cardíacas. Para tanto, fez-se uma análise detalhada de dois algoritmos: HMM (Hidden Markov Model) e rede neural artificial do tipo RBF (Radial Basis Function), com a finalidade de reconhecer três arritmias e o ritmo normal. As arritmias que foram utilizadas na pesquisa são: a Fibrilação Atrial, a Taquicardia Ventricular e a Fibrilação Ventricular. Tais arritmias foram selecionadas pela necessidade de desfibrilação elétrica imediata na Taquicardia Ventricular e na Fibrilação Ventricular e pelo fato da Fibrilação Atrial ser a arritmia de maior incidência na população mundial. A necessidade de reconhecimento de arritmias pode ser vista em equipamentos DEA (Desfibriladores Externos Automáticos), utilizados para reconhecer e reverter a parada cardíaca em locais fora de ambientes hospitalares. Estes equipamentos estão sendo cada vez mais utilizados em vários países, como uma tentativa de diminuir o índice de mortalidade. Primeiramente, foi feito um estudo teórico sobre o coração, analisando as características de cada tipo de arritmia, a fim de poder identificá-las. Os pacientes foram selecionados no banco de dados de sinais biológicos, PhysioNet, para coleta de dados. Após isso, foi feita uma análise teórica detalhada dos sistemas de reconhecimento e em seguida, passou-se a gerar resultados a partir da comparação entre os algoritmos e suas precisões. Para atingir tais resultados, foi elaborada uma metodologia específica de pesquisa. Ao final, foi possível constatar que ambos algoritmos apresentam bom desempenho no reconhecimento das arritmias cardíacas, bem como também foi possível expor as características de desempenho de cada um dos sistemas.
|
Page generated in 0.0676 seconds