• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 6
  • 6
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uma solução para economia de ar comprimido em sistemas de controle de posição pneumáticos

Endler, Luciano January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Automação e Sistemas, Florianópolis, 2014. / Made available in DSpace on 2015-03-18T20:58:03Z (GMT). No. of bitstreams: 1 332240.pdf: 5367886 bytes, checksum: 1ab5bb9dc97bbd102d3929b240ec612b (MD5) Previous issue date: 2014 / Este trabalho apresenta um estudo teórico e experimental de um esquema alternativo para a economia de ar comprimido em sistemas de posicionamento pneumáticos que necessitam mover cargas elevadas. Este novo esquema adiciona uma válvula on/off de rápida comutação em uma realimentação entre as câmaras do atuador pneumático. Primeiramente, a modelagem matemática foi desenvolvida, tanto para entender o comportamento do sistema com válvula auxiliar, quanto no desenvolvimento do algoritmo para a economia de ar comprimido. A modelagem consiste em equacionar o comportamento dinâmico e estático dos principais componentes, como a válvula auxiliar on/off de rápida comutação, válvula proporcional e sistema de atuação pneumático. O algoritmo para economia de ar comprimido leva em conta a diferença de pressões nas câmaras do atuador e o sinal de controle de referência para a tomada de decisão de acionamento das válvulas. O sistema usa dois controladores, sendo que o sinal de controle enviado à válvula proporcional provém de um controlador PI com compensação da não linearidade da zona morta a partir da sua inversa suavizada e para o sinal enviado a válvula on/off de rápida comutação, uma técnica de Modulação por Largura de Pulso associada com um controlador PI foi implementada. Os resultados teórico-experimentais foram obtidos por intermédio da modelagem não linear detalhada do sistema e da utilização de uma bancada de testes. O modelo teórico apresentou um comportamento próximo do comportamento real de forma que foi utilizado para a determinação da diferença de pressão necessária para conseguir uma realimentação entre as câmaras do atuador pneumático e atingir os requisitos de posicionamento do sistema. Essa diferença de pressão é um parâmetro importante para garantir o funcionamento do algoritmo para economia de ar comprimido. Os resultados experimentais mostraram que, com esta configuração, até 47 % de ar comprimido pode ser economizado levando em conta a resposta ao degrau e de até 54% para o seguimento de trajetória senoidal. O custo extra para o acréscimo da válvula auxiliar pode ser compensado pela economia de ar comprimido. O período para retorno do investimento é de aproximadamente 0,9 anos para a sequência de entrada em degrau e 0,72 anos para o seguimento de trajetória senoidal, caso transdutores de pressão estejam disponíveis no sistema.<br> / Abstract : This work presents a theoretical and experimental study of an alternative scheme to compressed air saving in pneumatic positioning systems with need move high loads. This new scheme adds a fast switching on/off valve in a feedback between the chambers of the pneumatic actuator. Firstly, the mathematical modeling was developed to understand the behavior of the system with an auxiliary on/off valve and to developing of the algorithm to compressed air saving. The mathematical modeling consists in equating the static and dynamic behavior of the main components, like fast switching on/off valve, proportional valve and pneumatic actuator system. The algorithm to compressed air saving, takes into account the pressure difference in the actuator chambers and the control signal reference to make decision to activation of valves. The system use two controllers, being the proportional valve signal from a PI controller with compensation of nonlinearity dead zone from a smoothed inverse and in the signal sent to auxiliary fast switching on/off valve, a Pulse Width Modulation technique associated with a PI controller was implemented. The theoretical and experimental results were obtained, firstly with the simulation of the mathematical model and after from tests conducted on test bench. The theoretical model presents a behavior very close to the real behavior. Having the validated model, one can obtain the pressure difference required to achieve a feedback between the chambers of the pneumatic actuator and achieve the positioning requirements of the system. This difference in pressure is an important parameter for the algorithm for compressed air saving. The experimental results showed that, with this configuration, until 47 % of compressed air can be saved to step response and of up to 54% for the sinusoidal trajectory tracking. The extra cost for the addition of auxiliary valve can be offset by compressed air saving. The payback period is of approximately 0.9 years to steps inputs and of approximately 0.72 years to the sinusoidal trajectory tracking, if the pressure transducers are available in the system.
2

Manejo de irrigação por gotejamento para aplicação de água residuária visando a minimização do entupimento de emissores. / Drip irrigation techniques to mitigate the dripper clogging in wastewater irrigation.

Cararo, Denis Cesar 18 October 2004 (has links)
A escassez de água e a grande geração de esgoto doméstico com necessidade de tratamento estimulam o uso de águas residuárias na agricultura. A irrigação por gotejamento caracteriza-se como um sistema seguro para esta finalidade, mas possui como barreira tecnológica o entupimento dos gotejadores. Neste trabalho, objetivou-se selecionar modelos de gotejadores e manejos mitigadores do entupimento por uso de água residuária oriunda de tratamento secundário de esgoto doméstico. Desenvolveu-se o estudo em três etapas: (I) a caracterização de 15 modelos de gotejador novos, (II) a préseleção dos emissores e (III) a seleção da combinação manejo e modelo. Os manejos foram controle, cloração a 0,5 mg L-1 de cloro residual livre ao final da irrigação medido ao final do sistema, ar comprimido a 1,96 kPa na entrada dos emissores e a combinação de cloração e ar comprimido, utilizando-se filtragem de areia (De = 0,59 mm), disco (120 mesh) e tela (200 mesh) em todos os tratamentos. Procederam-se avaliações de vazão e cálculos de coeficiente de variação de vazão (CVq) e de grau de entupimento (GE). Os modelos apresentaram coeficiente de variação de fabricação aceitável e diferentes sensibilidades ao entupimento. O entupimento foi parcial, ocorreu de maneira desuniforme, independente da uniformidade de distribuição de água (UD) do emissor novo, e surgiu pela formação de biofilme bacteriano associado a sólidos dissolvidos. Houve aumentos de vazão em alguns modelos. A cloração reduziu o grau de entupimento ao longo do tempo e evitou o entupimento total em emissores. O modelo B associado à cloração apresentou a maior probabilidade de encontrar emissores na faixa de 5 % de variação de vazão em relação aos novos e o modelo M associado à filtragem ou a tratamentos com ar comprimido, as menores probabilidades. Os manejos mostraram-se semelhantes quanto ao GE e ao CVq e obtiveram-se valores de UD inferiores a 60 %, CVq superiores a 20 % e GE superiores a 5 %. Finalmente, de acordo com o objetivo, selecionou-se o modelo B associado à cloração como a combinação que melhor atenuou o entupimento dos emissores. / The sustainable management of water resources, given the current and projected severe water shortages, requires that appropriate methods of water usage be implemented. One of these is the application of treated wastewater to agricultural land using drip irrigation systems, which is safe and among the most resource efficient methods of irrigation. However, the use of drip irrigation with wastewater is constrained by the potential for clogging in the emitters. To elucidate the mechanism of clogging, fifteen drip emitters models from different manufacturers were tested with secondary treated wastewater in the laboratory and two field experiments were conducted to evaluate emitters and treatments according to the degree of clogging (DC) and flow rate coefficient of variation (CVq). The treatments were control (filtrage only), chlorination (0.5 mg L-1 free residual chlorine injected at the end of each irrigation cycle), compressed air (1.96 kPa in the inlet drippers) and the chlorine and compressed air combination. The manufacture coefficient of variation was acceptable and different clogging susceptibility. The clogging was partial, non-uniform and was caused by biofilm with dissolved solids. Some drippers with overflow rates were noted. The chlorination decreased clogging overtime and reduced the complete clogging. The dripper model B (pressure compensated, flat and inserted in the line, with rectangular elastic membrane over a 30 mm passageway, 0.8 mm narrowest aperture, 1.61 L h-1 under 98 kPa) with chlorination was identified as having the best performance, with the highest number of emitters with a flow rate within five percent of the flow rate when new, and the dripper model M with chlorination was the worst performance with the lowest percent. The filtrage, chlorine and air treatments did not have a statistically significant affect in the DC or CVq. Distribution uniformities higher than 60 %, CVq higher than 20 % and DC higher then 5 % were found. Finally, according to the purposed, It was selected the dripper model B with chlorination as the best combination to mitigate the clogging
3

Análise de trocadores de calor compactos para desumidificação de ar. / Analysis of compact heat exchanger for air dehumidification.

Cuadros Gutierrez, Paul Fernando 01 June 2006 (has links)
O objetivo deste trabalho é realizar uma análise paramétrica do processo de desumidificação de ar comprimido em trocadores de calor compactos com superfícies intensificadoras do tipo aletas deslocadas. A umidade contida no ar comprimido precisa ser retirada do sistema para evitar a formação de condensado nas linhas de distribuição, nos atuadores ou nos dispositivos finais. Utiliza-se o processo de desumidificação por resfriamento onde a temperatura do ar é diminuída até alcançar o ponto de orvalho, resultando em formação de condensado. O desumidificador é constituído por dois trocadores de calor (recuperador e evaporador), sendo cada um deles dividido em duas regiões. Realizou-se a modelagem do processo de transferência de calor para cada um dos trocadores. Utilizou-se o método do potencial de entalpias para determinar os coeficientes globais de transferência de calor de cada trocador. Para a realização da simulação numérica, foi implementado um programa utilizando como ferramenta computacional o programa “Engineering Equation Solver" (EES). O estudo foi feito variando-se os parâmetros geométricos do trocador de calor e verificando sua influência nos coeficientes de transferência de calor, nos calores trocados e nas condições de saída do ar. Primeiramente, cada parâmetro foi analisado individualmente e depois com algumas combinações. Concluiu-se que as dimensões das aletas no recuperador e os comprimentos do recuperador e do evaporador são os parâmetros que mais influenciam nas propriedades do ar comprimido na saída do desumidificador. / The objective of this work is to conduct a parametric analysis of the dehumidification process of compressed air in compact heat exchangers with Offset Strip Fins. The humidity carried by the compressed air should be removed from the system to prevent the condensation in the distribution lines and in the actuators or the final devices. The dehumidification process by cooling occurs when the temperature of the air is diminished until reaching the dew point, resulting in condensation of water vapor. The dehumidifier is constituted by two heat exchangers (recuperator and evaporator), each one of them being divided in two regions. A modeling of the heat and mass transfer process for each heat exchangers, was performed. The enthalpy driving potential method was used to determine the overall heat transfer coefficients of each heat exchanger. The numerical simulation was implemented by using the computational software "Engineering Equation Solver"(EES). The study was made varying the geometric parameters of the heat exchanger and verifying its influences on the heat transfer coefficients, the heat transfer and pressure drop, and the air exit conditions. First, each parameter was analyzed individually and then with some combinations. Its was concluded that the fins dimensions in both regions of the lengths of the recuperator and the evaporator are the parameters that have larger influence on the exit compressed air properties.
4

Eficiência energética aplicada na indústria de bebidas em sistemas de refrigeração e ar comprimido: estudo de casos

Mendes, Jair Eduardo Alves [UNESP] 16 January 2014 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-16Bitstream added on 2014-06-13T21:00:27Z : No. of bitstreams: 1 000755220.pdf: 14142750 bytes, checksum: 102189dd2a552dfabaaa76b366358524 (MD5) / A eficiência energética aos poucos vai ganhando espaço nas indústrias, em função da redução dos custos de produção, pela política de sustentabilidade e de preocupação ambiental empregada atualmente. As indústrias de bebidas, como a que o trabalho foi implantado, utilizam muito o sistema de refrigeração e o de ar comprimido. Praticamente 50% do consumo destas fábricas são em função destas utilidades. O objetivo desta dissertação foi desenvolver uma metodologia para ser usada como ferramenta na identificação de oportunidades de redução do consumo de energia em sistemas de refrigeração e ar comprimido. A metodologia desenvolvida foi baseada em conceitos de refrigeração e ar comprimido e, em alguns estudos de casos de eficiência energética implantados em algumas unidades fabris. Este trabalho mostra como esta metodologia foi criada para melhorar a eficiência energética de sistemas de refrigeração e de ar comprimido. Posteriormente esta metodologia foi utilizada em outras unidades desta mesma indústria para reduzir o consumo de energia elétrica. Inicialmente há uma breve descrição dos principais componentes destes sistemas e de conceitos que ajudam na melhoria da eficiência deles. Por fim, são apresentadas algumas boas práticas e projetos implementados que ajudaram na criação da ferramenta ou foram implementados a partir do uso dela. Os resultados do trabalho mostram a ferramenta pronta para ser usada e uma redução do consumo de energia elétrica de mais de 37 GWh/ano, que significam mais de R$ 6.000.000,00 por ano. A principal conclusão desta dissertação é que a metodologia foi criada e, independente do tipo de configuração destes dois sistemas, é possível utilizá-la para melhorá-los / Energy efficiency is slowly gaining ground in the industry, especially due to the cost reduction in the production process its present, also to the sustainability policy and environmental concern employed nowadays. Beverage industries use cooling system and compressed air system a lot. Almost 50% of the electricity consumption in these plants refers to those utilities. The objective of this dissertation was to develop a methodology that can be used as a tool for identifying opportunities to reduce energy consumption in those cooling and compressed air systems. The methodology was based on concepts of cooling and compressed air, and also in some case studies in which energy efficiency was implemented in beverage plants. This dissertation shows how this methodology was created to improve the energy efficiency in cooling and air compressed systems. Later this methodology was used in other plants of the same company in which the case study was done to reduce electricity consumption. The study starts with a short description of the main components of these systems and concepts that help to improve their efficiency. And concludes with some good practices operation and projects implemented, which helped to develop the tool or have been implemented using it. The outcome shows that the tool is ready for use and that there is an important reduction in electricity consumption, amount to more than 37 GWh / year, which means more than R$ 6,000,000.00 a year. The main conclusion of this dissertation is that methodology was developed and it is possible to use the methodology to improve the cooling and air compressed systems, apart from the configuration and automation of the equipments in the plant
5

Análise de trocadores de calor compactos para desumidificação de ar. / Analysis of compact heat exchanger for air dehumidification.

Paul Fernando Cuadros Gutierrez 01 June 2006 (has links)
O objetivo deste trabalho é realizar uma análise paramétrica do processo de desumidificação de ar comprimido em trocadores de calor compactos com superfícies intensificadoras do tipo aletas deslocadas. A umidade contida no ar comprimido precisa ser retirada do sistema para evitar a formação de condensado nas linhas de distribuição, nos atuadores ou nos dispositivos finais. Utiliza-se o processo de desumidificação por resfriamento onde a temperatura do ar é diminuída até alcançar o ponto de orvalho, resultando em formação de condensado. O desumidificador é constituído por dois trocadores de calor (recuperador e evaporador), sendo cada um deles dividido em duas regiões. Realizou-se a modelagem do processo de transferência de calor para cada um dos trocadores. Utilizou-se o método do potencial de entalpias para determinar os coeficientes globais de transferência de calor de cada trocador. Para a realização da simulação numérica, foi implementado um programa utilizando como ferramenta computacional o programa “Engineering Equation Solver” (EES). O estudo foi feito variando-se os parâmetros geométricos do trocador de calor e verificando sua influência nos coeficientes de transferência de calor, nos calores trocados e nas condições de saída do ar. Primeiramente, cada parâmetro foi analisado individualmente e depois com algumas combinações. Concluiu-se que as dimensões das aletas no recuperador e os comprimentos do recuperador e do evaporador são os parâmetros que mais influenciam nas propriedades do ar comprimido na saída do desumidificador. / The objective of this work is to conduct a parametric analysis of the dehumidification process of compressed air in compact heat exchangers with Offset Strip Fins. The humidity carried by the compressed air should be removed from the system to prevent the condensation in the distribution lines and in the actuators or the final devices. The dehumidification process by cooling occurs when the temperature of the air is diminished until reaching the dew point, resulting in condensation of water vapor. The dehumidifier is constituted by two heat exchangers (recuperator and evaporator), each one of them being divided in two regions. A modeling of the heat and mass transfer process for each heat exchangers, was performed. The enthalpy driving potential method was used to determine the overall heat transfer coefficients of each heat exchanger. The numerical simulation was implemented by using the computational software "Engineering Equation Solver"(EES). The study was made varying the geometric parameters of the heat exchanger and verifying its influences on the heat transfer coefficients, the heat transfer and pressure drop, and the air exit conditions. First, each parameter was analyzed individually and then with some combinations. Its was concluded that the fins dimensions in both regions of the lengths of the recuperator and the evaporator are the parameters that have larger influence on the exit compressed air properties.
6

Manejo de irrigação por gotejamento para aplicação de água residuária visando a minimização do entupimento de emissores. / Drip irrigation techniques to mitigate the dripper clogging in wastewater irrigation.

Denis Cesar Cararo 18 October 2004 (has links)
A escassez de água e a grande geração de esgoto doméstico com necessidade de tratamento estimulam o uso de águas residuárias na agricultura. A irrigação por gotejamento caracteriza-se como um sistema seguro para esta finalidade, mas possui como barreira tecnológica o entupimento dos gotejadores. Neste trabalho, objetivou-se selecionar modelos de gotejadores e manejos mitigadores do entupimento por uso de água residuária oriunda de tratamento secundário de esgoto doméstico. Desenvolveu-se o estudo em três etapas: (I) a caracterização de 15 modelos de gotejador novos, (II) a préseleção dos emissores e (III) a seleção da combinação manejo e modelo. Os manejos foram controle, cloração a 0,5 mg L-1 de cloro residual livre ao final da irrigação medido ao final do sistema, ar comprimido a 1,96 kPa na entrada dos emissores e a combinação de cloração e ar comprimido, utilizando-se filtragem de areia (De = 0,59 mm), disco (120 mesh) e tela (200 mesh) em todos os tratamentos. Procederam-se avaliações de vazão e cálculos de coeficiente de variação de vazão (CVq) e de grau de entupimento (GE). Os modelos apresentaram coeficiente de variação de fabricação aceitável e diferentes sensibilidades ao entupimento. O entupimento foi parcial, ocorreu de maneira desuniforme, independente da uniformidade de distribuição de água (UD) do emissor novo, e surgiu pela formação de biofilme bacteriano associado a sólidos dissolvidos. Houve aumentos de vazão em alguns modelos. A cloração reduziu o grau de entupimento ao longo do tempo e evitou o entupimento total em emissores. O modelo B associado à cloração apresentou a maior probabilidade de encontrar emissores na faixa de 5 % de variação de vazão em relação aos novos e o modelo M associado à filtragem ou a tratamentos com ar comprimido, as menores probabilidades. Os manejos mostraram-se semelhantes quanto ao GE e ao CVq e obtiveram-se valores de UD inferiores a 60 %, CVq superiores a 20 % e GE superiores a 5 %. Finalmente, de acordo com o objetivo, selecionou-se o modelo B associado à cloração como a combinação que melhor atenuou o entupimento dos emissores. / The sustainable management of water resources, given the current and projected severe water shortages, requires that appropriate methods of water usage be implemented. One of these is the application of treated wastewater to agricultural land using drip irrigation systems, which is safe and among the most resource efficient methods of irrigation. However, the use of drip irrigation with wastewater is constrained by the potential for clogging in the emitters. To elucidate the mechanism of clogging, fifteen drip emitters models from different manufacturers were tested with secondary treated wastewater in the laboratory and two field experiments were conducted to evaluate emitters and treatments according to the degree of clogging (DC) and flow rate coefficient of variation (CVq). The treatments were control (filtrage only), chlorination (0.5 mg L-1 free residual chlorine injected at the end of each irrigation cycle), compressed air (1.96 kPa in the inlet drippers) and the chlorine and compressed air combination. The manufacture coefficient of variation was acceptable and different clogging susceptibility. The clogging was partial, non-uniform and was caused by biofilm with dissolved solids. Some drippers with overflow rates were noted. The chlorination decreased clogging overtime and reduced the complete clogging. The dripper model B (pressure compensated, flat and inserted in the line, with rectangular elastic membrane over a 30 mm passageway, 0.8 mm narrowest aperture, 1.61 L h-1 under 98 kPa) with chlorination was identified as having the best performance, with the highest number of emitters with a flow rate within five percent of the flow rate when new, and the dripper model M with chlorination was the worst performance with the lowest percent. The filtrage, chlorine and air treatments did not have a statistically significant affect in the DC or CVq. Distribution uniformities higher than 60 %, CVq higher than 20 % and DC higher then 5 % were found. Finally, according to the purposed, It was selected the dripper model B with chlorination as the best combination to mitigate the clogging
7

Estudo de reaproveitamento de filmes de polietileno para fabricação de colchões de ar comprimido para utilização em embalagens de produtos eletroeletrônicos

OLIVEIRA, Macêdo Santos de 28 February 2011 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-28T13:15:39Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoReaproveitamentoFilmes.pdf: 2707232 bytes, checksum: efb49a059d912dc993191c6a69fe5162 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-28T14:15:29Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoReaproveitamentoFilmes.pdf: 2707232 bytes, checksum: efb49a059d912dc993191c6a69fe5162 (MD5) / Made available in DSpace on 2017-03-28T14:15:29Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudoReaproveitamentoFilmes.pdf: 2707232 bytes, checksum: efb49a059d912dc993191c6a69fe5162 (MD5) Previous issue date: 2011-02-28 / Filmes de polietileno (PE) são comumente utilizados em embalagens de produtos pequenos, tais como embalagem para câmeras digitais, filmadoras, garrafas de vinhos, instrumentos médicos, etc. em função de propriedades importantes como resistência mecânica (vibração, queda, etc.), térmica (temperatura, umidade, pressão) aliada à facilidade de processamento e um custo compatível. Na embalagem de eletroeletrônicos, são utilizados filmes de PE de baixa densidade, dependendo do produto a ser embalado. Assim, neste trabalho, foram avaliados filmes de polietilenos de baixa densidade utilizados para embalar painéis display na linha de produção, constituídos de mesmo polímero, com a substituição das embalagens de poliestireno expandido (EPS) pelo filme de polietileno com colchão de ar inflado e com alterações das espessuras dos filmes foram submetidos ao processo de fusão de duas camadas para formações de colchões de ar, sob determinadas condições de temperatura e pressão, cuja expansão dos filmes resultou em significativas alterações de propriedades físicas, mecânicas. Os filmes foram caracterizados antes e após a sua soldagem para confecções dos colchões de ar, no formato de colunas de ar que podem ser moldadas em embalagens para produtos eletroeletrônicos. Foi observado que de acordo com a mudança do tipo de material que constituem os filmes de polietilenos, ou seja, quanto mais resistente ao teste de compressão, maior é o grau de absorção de impacto dessa matéria-prima quando inflado na forma de colchão de ar, isso significa uma excelente performance para resistir ao peso de um produto durante os teste mecânicos, tais como: teste de queda, teste de vibração, teste de temperatura e umidade. Os estudos mostram que podemos estudar e realizar teste com filmes de alta resistência e que sejam descartados nas fábricas e reprocessados para fabricação de calços infláveis para serem utilizados em diversos produtos. O reaproveitamento dessas matérias-primas ajuda a diminui o índice de resíduos descartados no meio ambiente. / Films of polyethylene (PE) are commonly used in packaging of small products such as packaging for digital cameras, camcorders, wine bottles, medical instruments, etc... as a function of important properties such as mechanical strength (vibration, drop, etc..) thermal (temperature, humidity, pressure) with the ease of processing and a cost. In electronics packaging, are used PE films of low density, depending on the product being package. In this work, films were evaluated as lowdensity polyethylene used for packing display panels on the production line, consisting of a single polymer, replacing the packaging of expanded polystyrene (EPS) by a polyethylene cushion with air mattress inflated with changes in the thickness of the films were subjected to the fusion of two layers of training for air mattresses, under certain conditions of temperature and pressure, where expansion of the films resulted in significant changes in physical, mechanical. The films were characterized before and after welding for clothing of air mattresses in the format of columns of air that can be molded into packaging for consumer electronics. It was observed that change according to the type of material making up the films of polyethylene, that is, the more resistant to compression test, the greater the degree of impact absorption when this raw material in the form of inflated air mattress this means an excellent performance to bear the weight of a product during the mechanical test, such as drop test, vibration test, test temperature and humidity. Studies show that we can study and test films with high strength and are discarded and reprocessed in the factories for the manufacture of inflatable cushions to be used in various products. The reuse of these raw materials helps to reduce the rate of waste disposed in the environment.
8

Sistemas centralizados de gases e vácuo medicinais

Santos, Rubia Alves da Luz January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T09:26:00Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T02:16:38Z : No. of bitstreams: 1 186106.pdf: 7872819 bytes, checksum: 4998eedca46af9a181601ff85cb431a7 (MD5) / Este trabalho aborda os sistemas centralizados de oxigênio, óxido nitroso, ar e vácuo medicinais, os quais são compostos pela central de suprimento, rede de distribuição e postos de utilização. Também retrata como a qualidade do gerenciamento destes sistemas influencia outros elementos da tecnologia médico-hospitalar, tais como os equipamentos que utilizam os gases e vácuo, o atendimento ao paciente, a efetividade e a relação custo-benefício. São discutidos aspectos relacionados ao projeto, execução e manutenção, após uma descrição da principais características dos sistemas centralizados e dos equipamentos que os compõem, bem como das recomendações normativas e regulamentações nacionais vigentes. Com base nas informações teóricas reunidas, um estudo de caso foi realizado através da coleta de dados e análise em centrais de suprimento e redes de distribuição de quatro hospitais públicos e quatro privados localizados no estado de Santa Catarina. Para quantificar a severidade e a ocorrência dos possíveis problemas decorrentes das desconformidades pesquisadas, propõe-se uma metodologia baseada na técnica de Análise de Efeitos, Modos de Falha e Criticalidade (FMECA). A análise dos dados da pesquisa mostra que algumas desconformidades encontradas independem do tipo de hospital, como exemplo, dos hospitais públicos e privados visitados, 100% não possuem alarmes operacionais indicando quando o suprimento secundário ou reserva está em operação e o acionamento é realizado de forma manual. O propósito deste trabalho é propor uma metodologia aplicável por estruturas de engenharia clínica, ou a assessoria destas estruturas aos profissionais responsáveis por estes sistemas, com o objetivo de melhorar a situação atual.
9

Método dos mínimos quadrados aplicados ao lançamento de foguetes propulsionados a ar comprimido / Least squares method applied to the launch of rockets propelled by compressed air

Silva Junior, Gilberto Caetano da [UNESP] 18 October 2017 (has links)
Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-12T23:01:48Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-22T14:06:59Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-22T18:09:14Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-22T18:12:24Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-22T19:44:22Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-23T11:57:15Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-23T12:57:56Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-23T13:16:32Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-23T13:34:45Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-23T17:24:54Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-23T17:29:02Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-24T12:05:25Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-24T12:39:45Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-24T16:47:39Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-24T17:31:21Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-27T11:40:49Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-27T12:31:51Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-27T13:03:16Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-27T18:08:08Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-28T12:13:07Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-28T14:22:46Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-28T14:31:58Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Submitted by GILBERTO CAETANO DA SILVA JÚNIOR null (gilcaju@ig.com.br) on 2017-11-28T14:37:46Z No. of bitstreams: 1 versão definitiva.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Approved for entry into archive by Adriana Aparecida Puerta null (dripuerta@rc.unesp.br) on 2017-11-28T18:25:00Z (GMT) No. of bitstreams: 1 silvajunior_gc_me_rcla.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) / Made available in DSpace on 2017-11-28T18:25:00Z (GMT). No. of bitstreams: 1 silvajunior_gc_me_rcla.pdf: 1724008 bytes, checksum: c953406384f7a6ee2d78df6e9f2ae70b (MD5) Previous issue date: 2017-10-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho, apresentamos um relato de experimento realizado junto aos alunos de ensino fundamental de uma escola pública municipal e efetuamos o ajuste de curva dos dados observados por meio do método dos mínimos quadrados. Para tanto, discutimos a concepção e aplicação desse método a partir de resultados oriundos do cálculo diferencial, da álgebra linear e alguns conceitos estatísticos. Do cálculo diferencial estudamos a minimização dos erros de aproximação por meio da investigação dos pontos de mínimo da função erro. Da álgebra linear determinamos os parâmetros da função ajustada através da discussão e solução de um sistema de equações lineares resultante do conjunto de derivadas parciais nulas que estabelecem o ponto crítico da função erro. Da estatística utilizamos alguns conceitos e formulações que tratam da intensidade da relação entre as variáveis, bem como, das incertezas na variável dependente e nos parâmetros da função ajustada. / In this work, we present a report of an experiment carried out with elementary school students of a municipal public school, and we performed the curve adjustment of the observed data through the least squares method. For this, we discuss the conception and application of this method from results derived from differential calculus, linear algebra and some statistical concepts. From the differential calculation, we study the minimization of approximation errors by investigating the minimum points of the error function. From linear algebra, we determine the parameters of the adjusted function through the discussion and solution of a system of linear equations resulting from the set of null partial derivatives that establish the critical point of the error function. From statistics, we use some concepts and formulations that deal with the intensity of the relationship between variables, as well as the uncertainties in the dependent variable and the parameters of the adjusted function.
10

Caracterização e teste de adsorventes para produção de oxigénio por PSA

Magalhães, Roberto Carlos Pinto January 2011 (has links)
Documento confidencial. Não pode ser disponibilizado para consulta / Tese de mestrado integrado. Engenharia Química. Universidade do Porto. Faculdade de Engenharia. 2011