• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1110
  • 24
  • 3
  • 1
  • Tagged with
  • 1138
  • 431
  • 429
  • 331
  • 303
  • 280
  • 251
  • 247
  • 239
  • 234
  • 196
  • 160
  • 150
  • 148
  • 131
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação da eficácia do ácido peracético como desinfetante de resinas acrílicas

Chassot, Ana Lucia Campani January 2001 (has links)
Para prevenir a transmissão de doenças entre pacientes e profissionais, é necessária a adoção de medidas de controle de infecção cruzada. Uma dessas medidas é a desinfecção de aparatos de resina adliça. O glutaraldeído e o hipocloito de sbdio tem sido recomendados para a desinfecção deste material, entretanto estes desinfetantes ngo são ideais para tal fim. O ácido peracetico, utilizado na Medicina para desinfeção de materiais termossensiveis, é um desinfetante eficaz e não deixa residuos tóxicos e pode ser uma alternativa. Sendo assim o objetivo deste trabalho foi avaliar a eficácia antimicrobiolbgica do ácido peracético na desinfecção de resinas acrlíicas. Foram testadas as resinas acrílicas termicamente ativada, quimicamente ativada e polimerizada em forno de microondas. As resinas foram contaminadas através do uso intraosal durante sete noites e também através do contato com microrganismos conhecidos: Bacillus subtilis e Bacillus tearothemrophilus. Os corpos de prova de resina amílica comaminada foram imersos em ácido peracético 0,2% (Sterilie®/Lifemed, São Paulo, SP) durante 5 minutos e então colocados no meio de cultura BHI (Brain Hemt lnfiszon) Após o período de incubação, a observação do crescimento bacteriano foi feita através da análise da turvação do meio de cultura. Cem por cento dos corpos de prova contaminados e colocados diretamente no meio de cultura (grupo controle) provocaram turvação do meio de cultura enquanto que nenhum dos demais corpos de prova de resina aciílica termicamente ativada, de resina acriiica quimicamente ativada e de resina acrilica polimerizada em microondas turvaram o meio, após imessão em ácido peracético por 5 minutos, comprovando a eficácia do mesmo. Concluiu-se que a imersão em ácido peracético durante 5 minutos e eficaz na desinfecção de resinas acrilicas contaminadas com Bacillus subtilis, ou com Bacillus tearothermophílzcs ou com saliva humana. Para que se estabeleça um protocolo de desinfecção de resinas acrilicas, são necessários trabalhos que provem a inércia do ácido peracético sobte as propriedades fisicas e químicas das resinas.
32

Um Sistema de alertas inteligentes para ambientes de ensino na internet

Musa, Daniela Leal January 2001 (has links)
A difusão da educação baseada na Web está trazendo uma série de mudanças nesta área. Uma dessas mudanças está na forma de como se avaliar as atividades dos alunos remotos, não só através de tarefas tradicionais como testes, mas verificando, em tempo-real, as ações dos alunos e assim possibilitando ao professor um acompanhamento mais completo das atividades dos estudantes. De acordo com os recursos computacionais existentes, a utilização de um Sistema de Alertas é a opção que melhor se adequa a estas finalidades, pois com este tipo de sistema é possível acompanhar as atividades dos alunos em cursos a distância. O objetivo deste trabalho é apresentar um Sistema de Alertas Inteligentes para apoio ao ensino, que detecta problemas nas atividades dos alunos em cursos na Web e realiza ações corretivas adequadas. Este sistema está parcialmente integrado ao ambiente Tapejara do Instituto de Informática da UFRGS – Sistemas Inteligentes de Ensino na Web - que consiste em um sistema de construção e acompanhamento de cursos disponibilizados via Internet. A principal característica do Sistema de Alertas Inteligentes é a busca de situações críticas como, por exemplo: aluno apresenta baixo desempenho nos exercícios, a estratégia de ensino não corresponde ao perfil do estudante, aluno não está comparecendo às atividades do curso, etc. Com isto, este sistema pode auxiliar o professor (tutor virtual) a ter um acompanhamento mais preciso sobre as atividades realizadas pelo estudante e assim, adaptar as aulas às características do aluno, sem, com isto, acarretar numa sobrecarga de trabalho.
33

Avaliação da sorpção, solubilidade e microdureza de resinas acrílicas após desinfecção com ácido peracético

Hehn, Lisiane January 2001 (has links)
O objetivo deste trabalho foi avaliar a influência da desinfecção com ácido peracético a 0,2% (STERILIFE®, Lifemed Produtos Médicos Comércio Ltda, São Paulo,SP) sobre as propriedades de sorpção, solubilidade e microdureza Knoop das resinas acrílicas termopolimerizadas (RATA) e resinas acrílicas quimicamente ativadas (RAQA). Os ensaios de sorpção, solubilidade e microdureza Knoop foram realizados utilizando resina acrílica termopolimerizável e quimicamente ativada da marca CLÁSSICO (Art. Odontológicos Clássico Ltda, São Paulo, SP). A especificação nº 1567 da International Organization for Standardization (ISO) foi utilizada para a realização dos ensaios de sorpção e solubilidade. Foram confeccionados 20 corpos de prova de resina acrílica termopolimerizável e 20 corpos de prova de resina acrílica quimicamente ativada, divididos aleatoriamente em dois grupos de 10 corpos de prova para cada material. O primeiro grupo foi denominado grupo controle e o segundo foi submetido à desinfecção com ácido peracético por 10 minutos. Os corpos de prova cilíndricos com dimensões de 50mm de diâmetro e 0,5mm de espessura, foram mantidos em um dissecador com sílica gel, a 37°C, até a obtenção da massa constante (M1), obtida através de pesagens consecutivas em uma balança de precisão com resolução de 0,0001g. A seguir os corpos de prova foram imersos em água destilada a 37°C, durante 7 dias e posteriormente pesadas, para obtenção da massa M2. Após, os corpos de prova retornaram ao dissecador com sílica gel, a 37°C, até a obtenção da massa recondicionada (M3). A diferença entre M2 e M3 em relação ao volume do corpo de prova resultou na sorpção do mesmo e, a solubilidade foi calculada subtraindo M3 de M1 e dividindo pelo volume do corpo de prova. Para o ensaio de microdureza foram confeccionados 10 corpos de prova de cada resina. A mensuração da microdureza Knoop, utilizando o NU Research Microscope (VEB Carl Zeiss JENA- Germany), foi obtida antes e após a desinfecção de cada corpo de prova. Os resultados mostraram que a desinfecção com ácido peracético, tanto para as resinas acrílicas termopolimerizadas como para as quimicamente ativadas, não alterou significativamente as propriedades de sorpção e solubilidade, uma vez que continuaram atendendo às exigências da especificação nº 1567 da ISO, após o tratamento. Em relação a microdureza Knoop, os resultados mostraram que não houve diferença estatística significativa entre a microdureza anterior e posterior à desinfecção, tanto a resina de termopolimerização (p=0,992), como para a resina quimicamente ativada (p=0,999). Portanto, o processo de desinfecção de resinas acrílicas com ácido peracético, pode ser viável considerando as propriedades analisadas.
34

SADA sistema virtual de ensino com análise de desempenho e aplicação de avaliação na Web

Garcia, Melissa Speglic Zambrini January 2002 (has links)
Este trabalho apresenta um sistema virtual para suporte ao ensino, denominado SADA. O sistema se baseia na análise do desempenho durante a aprendizagem para implementar técnicas de adaptação para apresentação dos links. Tendo como objetivo principal auxiliar o ensino presencial, e caracterizar as possibilidades para se adaptar a navegação no conteúdo do curso através da forma de apresentação dos links. O SADA utiliza ferramentas computacionais de domínio público na Web, e possui um conjunto de opções para criação e divulgação de cursos com conteúdos didáticos, e questões de múltipla escolha para avaliação do desempenho do aluno. Um sistema de ensino como o SADA, mediado por computador e baseado na Internet (Web), pode ser uma ferramenta complementar ao trabalho do professor, por acrescentar maior dinâmica aos cursos ou disciplinas devido às novas formas de interação com o aluno.
35

Eficácia do LED na polimerização de um compósito

Campregher, Ulisses Bastos January 2003 (has links)
O objetivo deste estudo foi avaliar a eficácia de três aparelhos fotopolimerizadores comerciais que utilizam o LED como fonte de luz (Elipar FreeLight - 3M-ESPE, UltraLume-LED2 - Ultradent e Single V - BioArt) na polimerização do compósito Z250 (3M-ESPE), cor A3, através das propriedades: microdureza Knoop, profundidade de polimerização e resistência flexural. Um aparelho fotopolimerizador convencional de lâmpada halógena XL 2500 (3M-ESPE) foi utilizado como controle. Em todos os casos, o tempo de polimerização adotado foi de 20 s. Para o ensaio de microdureza foram confeccionados 10 corpos de prova cilíndricos com 8 mm de diâmetro e 2 mm de altura para cada aparelho fotopolimerizador. A microdureza foi medida 24 h após a confecção dos corpos de prova, que ficaram armazenados em ambiente seco e protegidos da luz. Para o ensaio de profundidade de polimerização foram confeccionados três corpos de prova cilíndricos com 4 mm de diâmetro e 6 mm de altura para cada aparelho fotopolimerizador. O ensaio foi realizado imediatamente após a polimerização do compósito. Para o ensaio de resistência flexural foram confeccionados 5 corpos de prova com 25 mm de comprimento, 2 mm de altura e 2 mm de largura para cada aparelho fotopolimerizador. A resistência flexural foi medida 24 h após a polimerização do compósito e armazenagem dos corpos de prova em água destilada a 37ºC. Os resultados obtidos foram comparados às exigências da especificação 4049:2000 da International Organization for Standardization (ISO) e submetidos à análise estatística para comparação entre os aparelhos. Os valores de microdureza obtidos com os três fotopolimerizadores com LED não mostraram diferença entre si e foram superiores aos obtidos com o aparelho convencional. Para o ensaio de profundidade de polimerização, os valores obtidos com o aparelho Single V foram superiores aos do aparelho convencional, enquanto que os obtidos pelos outros dois aparelhos não apresentaram diferenças significativas entre si e o convencional. Para o ensaio de resistência flexural, não houve diferença entre os valores obtidos pelos três aparelhos com LED e o aparelho convencional. As exigênias da ISO 4049:2000 para os ensaios de profundidade de polimerização e resistência flexural foram atendidas em todos os casos.
36

Avaliação de materiais resinosos com dupla função : cimentação de pinos radiculares e construção do núcleo de preenchimento coronário / Evaluation of core build-up cements for one-stage post endodontic restorations

Walcher, Juliana Gehlen January 2016 (has links)
O desenvolvimento constante de materiais odontológicos tem possibilitado a execução de técnicas restauradoras simplificadas visando facilitar a prática clínica. Dentre eles, são apresentados materiais à base de resina com a função de cimentação de pinos radiculares e também de construção do núcleo de preenchimento coronário. Para um bom desempenho das suas funções, esses materiais devem apresentar baixa viscosidade e alta resistência. O objetivo do presente trabalho foi avaliar propriedades de materiais que apresentam essa dupla função. Os materiais testados foram: Allcem Core (FGM), Rebilda DC (VOCO) e Luxacore Z (DMG), como agentes de cimentação e preenchimento coronário (grupos teste), Rely X ARC (3M ESPE), usado apenas para cimentação (grupo controle para cimentação), e GrandioSo (VOCO), indicado apenas para preenchimento coronário (grupo controle para preenchimento). Foram realizados ensaios de resistência à flexão (n=10), grau de conversão (GC) com espectroscopia Raman (n=5), espessura de filme (n=6), escoamento (n=6) e resistência ao deslocamento por teste de push-out (n=12). A resistência à flexão e a espessura de filme foram avaliadas de acordo com a ISO 4049:2009, e o escoamento foi avaliado de acordo com a ISO 6876:2001. Para realizar o teste de push-out, foram utilizados dentes bovinos, limpos e preparados para receber pinos de fibra de vidro. Os dados foram avaliados por ANOVA de 1 via, teste de Tukey e teste-t pareado. Os cimentos teste não apresentaram diferença estatística para a resistência à flexão em relação ao controle GrandioSo, exceto Luxacore Z (p<0,001). O grau de conversão imediato e após 24h dos cimentos teste não mostrou diferença estatística significativa tanto em relação ao material controle para cimentação quanto ao material controle para preenchimento (p>0,05). Todos os materiais exibiram um GC superior após 24h (p<0,05), exceto Luxacore Z (p=0,054). Os cimentos teste não apresentaram diferença estatística na espessura de filme quando comparados ao controle Rely X ARC (p=0,66). O escoamento do Allcem Core foi inferior ao grupo controle para cimentação (p=0,006). Os valores de resistência ao deslocamento (push-out) dos cimentos teste não apresentaram diferença estatística significativa quando comparados aos valores do grupo controle para cimentação na análise de cada terço (p>0,05) e foram inferiores no terço apical em comparação com o cervical no Luxacore Z (p=0,046). O tipo de falha mais comum (variando de 86,11% a 97,22%) ocorreu na interface entre dentina e cimento, após o teste de push-out. Concluiu-se que os materiais com dupla função testados apresentaram propriedades adequadas, quando comparados a materiais de indicação restrita para cimentação ou construção do núcleo de preenchimento coronário. / Objective: The purpose of this study was to evaluate properties of core build-up cements for one-stage post endodontic restoration. Methods: The tested materials were: Allcem Core (FGM), Rebilda DC (VOCO) and LuxaCore Z (DMG) as dual function cements; Rely X ARC (3M ESPE), used only for cementation, and GrandioSo (VOCO), used only for coronary filling. It was assessed flexural strength (n=10), immediate and 24h late degree of conversion (DC) with Raman spectroscopy (n=5), film thickness (n=6), flow (n=6) and resistance to dislodgment (RD) by push-out test (n=12). The flexural strength and the film thickness were evaluated in accordance with ISO 4049:2009 and the flow was evaluated in accordance with ISO 6876:2001. To assess the RD by push-out test, bovine teeth were prepared to receive fiber glass posts. Results: the test cements Allcem Core and Rebilda DC did not show statistic difference in flexural strength compared to GrandioSo (p>0.05), and Luxacore Z presented lower mean value than GrandioSo (p<0.001).The test cements did not present statistic difference in degree of conversion (immediate and 24h late) compared to each control material, (p>0.05) regardless of their indication (cementation or coronary filling). All materials tested showed a greater degree of conversion after 24h, except Luxacore Z (p=0.054). The test cements did not show statistic difference in the film thickness compared to Rely X ARC (p=0.66), and did not show statistic difference in flow compared to control Rely X ARC (p>0.05), except Allcem Core (p=0.006). The resistance to dislodgment of the test cements did not differ from the control Rely X ARC, regardless the root third (p>0.05). Luxacore Z showed lower mean values in the apical third compared to the coronal third (p=0.046). The most prevalent failure mode after the push-out test was at dentine/cement interface, and it varied from 86.11% to 97.22%. The most common failure mode after the push-out test was at dentine/cement interface. Conclusion: The test cements presented adequate properties when compared with their control materials for cementation and coronary filling.
37

Avaliação de desempenho multicritério como apoio à gestão dos serviços logísticos

Gabriel, Michele January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia de Produção, Florianópolis, 2015 / Made available in DSpace on 2015-06-02T04:09:45Z (GMT). No. of bitstreams: 1 333889.pdf: 11376963 bytes, checksum: b162974faeb5265cc1ba605f993b0f0b (MD5) Previous issue date: 2015 / O acirramento da competição ocorrida nas últimas duas décadas fez com que as empresas particularmente as do setor de transformação de produtos primários pecuários revisassem suas estratégias operacionais. Uma destas foi à distribuição de seus produtos processados de aves e suínos que passou a ser terceirizada em grande parte das organizações deste setor. A sofisticação operacional e flexibilidade passaram a ser o diferencial competitivo para estas empresas dedicadas exclusivamente à distribuição de produtos acabados. O objetivo desta pesquisa é construir um modelo para apoiar a gestão de uma empresa de distribuição de produtos processados de aves e suínos visando monitorar e aperfeiçoar os fatores críticos para sua competitividade e reconhecendo as singularidades dos clientes, região onde se encontra e produtos a serem distribuídos, segundo a percepção de seu responsável. O instrumento de intervenção utilizado foi a metodologia Multicritério de Apoio à Decisão - Construtivista (MCDA-C). Como resultado, foram identificados e ponderados seus objetivos estratégicos e seus desmembramentos para permitir sua operacionalização e mensuração. O modelo permitiu visualizar gráfica e numericamente o perfil de desempenho atual e mensurá-lo em 58 critérios. O modelo identificou oportunidades de melhoria em aspectos operacionais tais como: Gestão da Carga mínima rentável; Controle da localização de produtos; Manutenção dos Caminhões; e, Acomodação dos produtos no caminhão, vinculados ao Objetivo Estratégico "Controle Operacional". As melhorias propostas permitiram aumentar a performance dos 49 pontos iniciais para 59 pontos. O gestor passou a dispor de um modelo de gestão que lhe permite conhecer suas potencialidades e fraquezas atuais bem como as consequências de suas decisões em seus objetivos estratégicos lhe permitindo agir com presteza para manter e melhorar sua competitividade.<br> / Abstract: Fierce competition occurred in the last two decades has meant that companies particularly the processing of livestock commodities sector revise their operational strategies. One of these was the distribution of its products processed poultry and pork which came to be outsourced in most organizations of this sector. The operational sophistication and flexibility have become the competitive advantage for these companies dedicated exclusively to the distribution of finished products. The objective of this research is to build a model to support the management of a company distributing products processed poultry and pork seeking to monitor and improve critical to their competitiveness and recognizing the uniqueness of each client, and the region where the products to be distributed as perceived from your parent. The instrument used was the intervention methodology Multicriteria Decision Support - Constructivist (MCDA - C). As a result, we identified and weighted its strategic goals and its ramifications to enable its operationalization and measurement. The model enables to visualize graphically and numerically the profile of current performance and measure it on 58 criteria. The model identified opportunities for improvement in operational aspects such as: Management Minimum Load profitable; Controlling the location of products; Maintenance Trucks, and accommodation of the products in the truck, tied to Strategic Objective "Operational Control". The proposed improvements have increased the performance of the initial 49 points to 59 points. The manager now has a management model that allows you to know your strengths and weaknesses as well as the actual consequences of their decisions on their strategic objectives allowing you to act swiftly to maintain and improve their competitiveness.
38

Avaliação da implantação da atenção à hipertensão arterial pelas equipes de saúde da família do município de Recife - PE / Evaluation of the implantation of the attention to the hypertension for the teams of family health of the city of Recife - PE

Costa, Juliana Martins Barbosa da Silva January 2007 (has links)
Made available in DSpace on 2012-05-07T14:43:56Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 000017.pdf: 996599 bytes, checksum: 4a2cb88071dff73236727a28f00533c8 (MD5) Previous issue date: 2007 / O controle da hipertensão arterial tem se apresentado como uma das estratégias prioritárias para diminuir a crescente morbimortalidade por doenças cardiovasculares. O presente estudo tem como objetivo avaliar a implantação da atenção à hipertensão arterial pelas equipes de Saúde da Família (ESF) do município do Recife-PE, em 2006. Foi realizada uma avaliação normativa das dimensões da estrutura e do processo de trabalho para definição do grau de implantação da atenção ao hipertenso e analisado elementos contextuais, considerando-se as dimensões políticonormativa e técnico-gerencial e organizacional. Foi construído um modelo lógico da atenção ao hipertenso na atenção básica, a partir de informações constantes em documentos oficiais, normas e estudos realizados. O modelo lógico subsidiou a construção dos instrumentos de coleta de dados. Para verificação do grau de implantação foi utilizado um questionário estruturado que foi aplicado a profissionais (médico ou enfermeira) de 72 ESF. Utilizou-se um sistema de escores que permitiu classificar o grau de implantação das atividades propostas, em excelente quando apresentou de 90 a 100 por cento das atividades implantadas, satisfatório de 70 a 79 por cento, insatisfatório de 50 a 69 por cento e crítico menor que 50 por cento. Para análise do contexto foram entrevistados os coordenadores do programa de hipertensão arterial nos Distritos Sanitários e analisados documentos oficiais. Os principais achados apontam para uma significativa fragilidade na atenção ao hipertenso. A ausência de uma coordenação geral do programa e a insipiência das coordenações dos DS foi uma das principais razões do baixo desempenho encontrado. O grau de implantação da atenção a hipertensão arterial foi insatisfatório em todos os Distritos Sanitários. A dimensão da estrutura aproximou-se do nível crítico do grau de implantação. As principais dificuldades encontradas na dimensão da estrutura foram: infra-estrutura das Unidades de Saúde da Família inadequadas, deficiência de insumos e uma baixa qualificação dos profissionais na atenção ao hipertenso. Na dimensão do processo de trabalho as principais fragilidades foram quanto a realização de atividades preventivas coletivas, o agendamento das consultas de acordo com o risco ou necessidade do hipertenso e no uso da informação para o planejamento de ações. O planejamento mostrou-se crítico tanto por parte dos profissionais das ESF quanto pela coordenação do programa nos Distritos Sanitários
39

Supervisão no programa de saúde da família: limites e possibilidades / Supervision in the program of family health: limits and possibilities

Reis, Claudia da Costa Leite January 2001 (has links)
Made available in DSpace on 2012-09-06T01:12:25Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 498.pdf: 1247809 bytes, checksum: fd6e6f72ea01bb19b50f7ac352774c79 (MD5) Previous issue date: 2001 / O presente estudo, com base numa abordagem qualitativa, utilizando como princípio metodológico o estudo de caso, discute a supervisão no Programa de Saúde da Família (PSF) do Município de Teresópolis, no Estado do Rio de Janeiro. Este programa, implantado no Brasil em 1994, se constitui numa estratégia de reorientação da atenção básica do Sistema Único de Saúde (SUS). A supervisão é um importante instrumento no gerenciamento de programas de saúde, motivo pelo qual objetivou-se analisá-la, descrevendo as suas características, o seu padrão de funcionamento, identificando os fatores subjetivos que podem interferir na dinâmica deste processo, delineando o perfil do supervisor do PSF, bem como refletindo sobre a supervisão como fator essencial de implantação do programa. Para tal realizou-se pesquisa bibliográfica e documental, além de entrevistas com os supervisores do programa e com os membros das equipes que compõem o PSF de Teresópolis, para identificar percepções, atitudes, valores e tendências destes em relação à supervisão. Permite reinterpretar a supervisão em saúde, especificamente no PSF, mostrando que ela é um processo em construção que incentiva a reflexão das práticas de saúde; possibilita o crescimento profissional, favorecendo-lhes o desenvolvimento da liberdade e da autonomia, contribuindo para o aprimoramento e sustentação de um programa que atenda às necessidades de saúde da população e leve à mudança do modelo assistencial brasileiro.
40

Instrumento para avaliar a implantação do programa nacional de controle da dengue no âmbito municipal / Instrument to evaluate the implantation of the National dengue control program in the municipal scope

Pimenta Junior, Fabiano Geraldo January 2005 (has links)
Made available in DSpace on 2012-09-06T01:12:36Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 725.pdf: 1336482 bytes, checksum: b14f0e5ccb1cdf95dcdf27082b7370ec (MD5) Previous issue date: 2005 / O presente trabalho propõe um instrumento para avaliar a implantação do Programa Nacional de Controle da Dengue - PNCD no âmbito municipal.A importância da dengue no contexto da saúde pública é apresentada, procurando demonstrar a evolução da situação epidemiológica e as diferentes formas que o governo brasileiro organizou as ações de prevenção e controle.Com o objetivo de fundamentar a proposta são discutidos os conceitos de vigilância, monitoramento e avaliação em saúde pública, ressaltando a oportunidade de eselecer na rotina do PNCD a prática desses conceitos.A proposta do instrumento foi elaborada a partir de um conjunto de indicadores anteriormente selecionados para a construção de um sistema de acompanhamento da implantação do programa - DIAGDENGUE, com a participação dos membros do Comitê Técnico de Acompanhamento e Assessoramento do PNCD, adaptando-os à realidade municipal. Foi também elaborado o modelo lógico do PCND, com os seus dez componentes, concentrando-se nas atividades e responsabilidades da esfera municipal de gestão.O processo de validação do instrumento deu-se a partir da análise e pontuação dos critérios propostos pelos membros do comitê, por intermédio do método delphis simplificado, em duas etapas, incorporando na segunda etapa as sugestões apresentadas pelos especialistas. Nessa etapa buscou-se eselecer uma comparação entre a situação identificada com a aplicação do questionário elaborado e as informações constantes nos sistemas de informação adotados pelo PNCD. Esse processo demonstrou que o instrumento proposto permite um aprofundamento na avaliação da implantação das ações de controle da dengue nos municípios. Após essa etapa, a proposta de questionário foi submetida aos coordenadores do programa de controle da dengue de nove municípios do Estado de Minas Gerais.Comparando-se os resultados obtidos, observa-se uma tendência dos representantes dos municípios valorizarem mais do que os especialistas as ações que fazem parte de sua rotina, como o envio das informações do FAD, de amostras para sorologia e isolamento viral, assim como os especialistas valorizaram mais as ações intersetoriais. Conclui-se apresentando uma proposta de instrumento que permite subsidiar e aprofundar a avaliação da implantação do PNCD, qualificando e apontando os avanços e deficiências de cada um dos dez componentes.

Page generated in 0.0506 seconds