• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avgränsningsmetodens betydelse för hydraulisk modellering av spill- och dagvattennät / The effects of delineation metods on hydraulic modelling of wastewater networks

Johansson, David January 2019 (has links)
Metoden för att avgränsa modellområdet i delavrinningsområden med homogena hydrologiska parametrar inför hydrauliska ledningsnätssimuleringar kan vara tidsödande. Olika metoder och tillvägagångssätt finns att tillgå, men kunskapen om hur valet av avgränsningsmetod påverkar simuleringsresultaten är begränsad.   I examensarbetet undersöktes hur fyra enkla avgränsningsmetoder, i jämförelse med två detaljerade metoder, påverkade en hydraulisk simulering av en regnhändelse på sex olika modelluppsättningar av spill- och dagvattennät. De detaljerade metoderna byggde på information om markhöjder i kombination med byggnaders placering, medan de enklare metoderna byggde på information om markhöjder respektive Thiessenpolygoner. Avgränsningsmetoderna testades för en dagvattenmodell, en kombinerad spill- och dagvattenmodell, och fyra spillvattenmodeller. Alla modellparametrar förutom de associerade med delavrinningsområdena (bidragande yta, koncentrationstid) hölls konstanta medan en regnhändelse med återkomsttid tio år och en maximal regnintensitet av 22,8 µm/s (82.1 mm/h) simulerades för varje avgränsningsmetod och modelluppsättning.    De olika metoderna gav upphov till skillnader i simulerat maximalt vattendjup i modelluppsättningarnas brunnar. De enklare metoderna tenderade att underskatta de simulerade vattendjupen och avvikelsen mot de detaljerade metoderna översteg 0,1 m, vilket utgjort en gräns för när avvikelsen får praktisk betydelse. Fler avvikelser erhölls uppströms i ledningsnätet och för modelluppsättningar med större avrinningsbildning. Inga entydigt upprepande förhållanden mellan metodernas påverkan på simuleringsresultaten mellan modelluppsättningarna fanns, varvid modellområdesegenskaper tros påverka effekten av vald avgränsningsmetod. Resultaten indikerade att det kan vara mer motiverat att använda enklare avgränsningsmetoder för spillvattenmodeller i förortsmiljö än för dagvattenmodeller i stadsmiljö, samt att metoder baserat på Thiessenpolygoner ger bättre överensstämmelse mot detaljerade metoder än de topografibaserade. / The method of delineating a model into sub-catchments with homogenous hydrological parameters, before performing hydraulic simulations, can be tedious work. Different approaches and methods for this purpose exist, but the understanding for how the choice of delineation method affects the modeling process and in the end the simulation results is limited.    This thesis explored how four simplified delineation methods, in comparison with two detailed methods, affected hydraulic simulation of a rain event on six different model set ups. The detailed methods were based on terrain analysis and property boundaries. The simplified methods were composed of twomethods based on terrain analysis of elevation models, and two methods based on Thiessen polygons. The delineation methods were applied on one stormwater model, one combined storm- and wastewater model, and on four wastewater models. All model parameters except for those associated with the sub-catchments (time of concentration, imperviousness) were kept constant as a scenario of a rain event with a return time period of 10 years and maximum intensity of 22.8 µm/s (82.1 mm/h) were simulated for every delineation method and model set up.   The different methods resulted in differences in simulated maximal water depth in the modelled manholes. The simplified methods tended to underestimate the water depth. Additionally, the deviation from the detailed methods exceeded 0.1m, which is a threshold value for when the deviations will be of practical importance. Greater deviations occurred upstream in the sewer system and for models with greater runoff volume. No unambiguous patterns were found between the methods and the model setups. Hence, the delineation methods cannot by themselves explain the observed deviation in the simulated water depths. The results indicate that it is more suitable to apply a simple method on a sewage model in a suburban area, than for a stormwater model in an urban area. In addition, the simplified methods based on Thiessen polygons showed more agreement with the detailed methods than the simple methods based on terrain analysis.
2

Mass flows of per- and polyfluoroalkyl substances (PFASs) in a Swedish wastewater network and treatment plant / Massflöden av per- och polyfluoralkylerade substanser (PFAS) i ett svenskt ledningsnät och reningsverk

Glimstedt, Linda January 2016 (has links)
Per- and polyfluoroalkyl substances (PFASs) are man-made substances that hold unique properties. They are not only oil- and water repellants but also very resistant to degradation. Due to these properties, the applications are endless and PFASs can be found in a wide range of industrial applications and commercial products. The effluents of wastewater treatment plants (WWTPs) have been pointed out as one of the major sources of PFASs in the environment. The main aim of this project was to evaluate the sources and the occurrence of PFASs in a wastewater network in a Swedish city and in the different treatment steps at the connected WWTP. Another objective was to use these data to calculate mass flows and to investigate the fate of PFASs within the WWTP. The city of Uppsala and the WWTP Kungsängsverket were selected as study objects. Both wastewater and sludge were sampled and analyzed. In the wastewater network, a total of 15 pumping stations (PSTs) were sampled for wastewater, and at the WWTP, a total of 10 wastewater and 10 sludge samples were taken. The samples consisted of grab samples (n = 24), time-integrated samples (100 mL every 20 min during 24 hours, n = 2) and flow proportional samples (24 hours, n = 9). The aqueous and sludge samples were prepared for analysis using solid-phase and solid liquid extraction, respectively, and then analyzed by liquid chromatography tandem mass spectrometry (LC/MS/MS). The PFAS concentrations and composition profiles varied greatly in the network. High concentrations of 6:2 fluorotelomer sulfonate (6:2 FTSA) were generally found in the wastewater, which indicates increased usage of 6:2 FTSA in industrial processes and applications as replacement for perfluorooctane sulfonate (PFOS) and/or leaching from fire-training sites. A hot spot was detected (Sågargatan PST: ΣPFAS = 55,000 ng L-1 = 110,000 mg d-1) with elevated discharges of C3 – C8 perfluoroalkyl carboxylates (PFCAs). The studied WWTP was ineffective in removing C4, C6, C8 perfluoroalkyl sulfonates (PFSAs), C3 – C8 PFCAs and 6:2 FTSA from wastewater. Longer chained C9 – C17 PFCAs tended to partition to sludge more effectively than shorter chained C3 – C8 PFCAs, where PFCAs with an even amount of perfluorated carbon atoms had a higher affinity for sludge than those with an odd amount. The PFAS concentrations and mass flows tended to increase across the second clarifier in both wastewater and sludge, probably due to precursor degradation. PFSAs and PFCAs tended to be at similar or lower concentrations in the effluent compared to the influent. This shows that these substances enter the WWTP from an upstream source and are not formed or added in the WWTP. The transformation of precursors is therefore not the most important source of PFASs in Kungsängsverket. PFASs in wastewater at a large scale municipal WWTP may origin to a large extent from both industrial applications and domestic sources, such as daily life products. The new knowledge generated within this project will help Uppsala Vatten to protect drinking water supplies and the receiving aquatic environment from PFAS contamination. / Per- och polyfluoroalkylerade substanser (PFAS) är konstgjorda ämnen som har unika egenskaper. De är inte bara fett- och vattenavvisande utan är även mycket resistenta mot nedbrytning. På grund av dessa egenskaper är applikationerna med PFAS oändliga, och de används i en lång rad industriella applikationer och kommersiella produkter. Renat vatten från avloppsreningsverk har pekats ut som en av de största källorna av PFAS i miljön. Syftet med det här projektet var att undersöka källorna och uppkomsten av PFAS i ett ledningsnät i en svensk stad och även före/efter de olika reningsstegen i det största reningsverket. Ett annat mål var att använda dessa data för att beräkna massflöden och att studera ödet för PFAS i reningsverket. Uppsala stad och reningsverket Kungsängsverket valdes som studieobjekt. Både avloppsvatten och slam provtogs och analyserades. I ledningsnätet provtogs totalt 15 pumpstationer (PST) med avseende på avloppsvatten och i reningsverket togs det totalt 10 avloppsvatten- och 10 slamprover. Proverna bestod av stickprover (n = 24), tidsintegrerade prover (100 mL var 20 min under 24 timmar, n = 2) och flödesproportionerliga prov (24 timmar, n = 9). Vatten- och slamproverna preparerades för analys med hjälp av fastfas- respektive fast-vätske-extraktion, och analyserades därefter med vätskekromatografi kopplat till tandem-mass-spektrometri (LC/MS/MS). PFAS koncentrationerna och sammansättningsprofilerna varierade mycket i ledningsnätet. Koncentrationerna av 6:2 fluorotelomersulfonsyra (6:2 FTSA) var generellt höga i avloppsvattnet, vilket tyder på en ökad användning av 6:2 FTSA i industriella processer och applikationer som ersättningssubstans för perfluorooktansulfonsyra (PFOS) och/eller urlakning från brandövningsplatser. En så kallad hot spot detekterades i ledningsnätet (Sågargatan PST: ΣPFAS = 55 000 ng L-1 = 110 000 mg d-1) med punktutsläpp av C3 – C8 perfluoroalkylerade karboxylsyror (PFCA). Det studerade reningsverket var inte effektivt för rening av C4, C6, C8 perfluoroalkyl-sulfonsyror (PFSAs), C3 – C8 PFCAs och 6:2 FTSA. PFAS av typen C9 – C17 PFCA (långa kolkedjor) tenderade att fördela sig till slamfasen mer än C3 – C8 PFCA (kortare kedjor), där PFCA med ett jämnt antal perfluorerade kolatomer hade större affinitet för slam än de med udda. PFAS koncentrationerna och massflödena tenderade att öka från första till andra sedimentations-tanken, både i avloppsvatten och i slam, troligtvis som en följd av degradering av prekursorer. PFSA och PFCA tenderade att ha likvärdiga eller lägre koncentrationer i ut- jämfört med inflöde. Detta tyder på att huvudkällorna för dessa substanser i avloppsvatten finns uppströms och uppkommer inte genom bildning eller tillsats i reningsverket. Nedbrytning av prekursorer är därför inte den viktigaste källan av PFAS i Kungsängsverket. Det visades tydligt att PFAS i ett kommunalt avloppsvatten kan ha sitt ursprung såväl i både industriella produkter och processer som produkter från hushåll, som t.ex. dagligvaruprodukter. Den nya kunskapen som genererats i detta projekt kommer att hjälpa Uppsala Vatten att skydda dricksvattentäkter och den mottagande akvatiska miljön för PFAS förorening.

Page generated in 0.0291 seconds