• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 352
  • 137
  • 71
  • 63
  • 45
  • 19
  • 18
  • 11
  • 11
  • 10
  • 6
  • 5
  • 5
  • 5
  • 2
  • Tagged with
  • 895
  • 139
  • 114
  • 69
  • 69
  • 66
  • 60
  • 56
  • 55
  • 51
  • 49
  • 48
  • 48
  • 47
  • 46
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação longitudinal da inclinação axial mesiodistal dos molares superiores decorrente do uso do aparelho Pendulum associado ao aparelho fixo por meio de radiografias panorâmicas / Longitudinal evaluation of axial mesiodistal inclination in maxillary molars as a result of using the Pendulum device associated with fixed appliance, through panoramic radiographs

Caroline Andrade Rocha 23 February 2011 (has links)
O objetivo deste estudo foi avaliar, por meio das radiografias panorâmicas, o comportamento longitudinal da inclinação axial mesiodistal dos molares superiores decorridos cinco anos após o tratamento realizado com o aparelho Pendulum seguido de aparelhagem ortodôntica fixa e comparar os resultados com os valores médios normais. A amostra consistiu de 20 pacientes (14 do gênero feminino e 6, do masculino) com má oclusão de Classe II tratada por meio da distalização dos molares superiores. A média da idade, ao início do tratamento (T1), foi de 14,27 ± 1,62 anos, ao final do tratamento (T2), 18,59 ± 1,82 anos, e, cinco anos pós-tratamento (T3), 23,77 ± 2,04 anos. A média do tempo de tratamento foi de 4,36 ± 0,79 anos e de avaliação pós-tratamento foi de 5,18 ± 1,14 anos. Como grupo controle, utilizou-se os valores angulares médios normais de molares superiores obtidos por Ursi (1989), sendo que essa obtenção partiu de radiografias panorâmicas de indivíduos com oclusão normal apresentando idades entre 12 e 17 anos. Para a análise estatística, utilizaram-se os traçados das radiografias panorâmicas nas 3 fases (T1, T2 e T3). Os dados obtidos foram analisados estatisticamente pelo teste ANOVA dependente seguido do teste de Tukey. As médias das inclinações axiais mesiodistais nas fases T1, T2 e T3 foram comparadas com os valores médios normais pelo teste t independente. Os resultados apontaram que os primeiros molares superiores, ao término do tratamento ortodôntico, estavam mais inclinados para a distal, porém, cinco anos após, tenderam a verticalizarem-se naturalmente, voltando a ocupar uma posição próxima ao inicial. Quando comparados com os valores normais, somente o primeiro molar superior esquerdo apresentou, no período T2, valor estatisticamente significante diferente do normal. Os valores correspondentes para os segundos molares superiores não apresentaram estatisticamente significantes quando comparados entre si, nem quando comparados com os valores normais. O tratamento com o Pendulum seguido de aparelhagem ortodôntica fixa promove uma inclinação das coroas dos molares para a distal, tendendo esses dentes, entretanto, no longo tempo pós-tratamento, a verticalizarem-se. / The objective of this study was to evaluate, through panoramic radiographs, the longitudinal conduct of mesiodistal inclination in maxillary molars five years after the treatment performed with the Pendulum device followed by fixed appliance and compare the results with normal mean values. The sample consisted of 20 patients (14 female and 6 male) with Class II malocclusion treated with molar distalization. The average age at pretreatment (T1) was 14.27 ± 1.62 years, at posttreatment (T2), 18.59 ± 1.82 years and at the long-term posttreatment (T3) 23.77 ± 2.04 years. The average length of time of the treatment was 4.36 ± 0.79 years and the evaluation of the long-term posttreatment was 5.18 ± 1.14 years. As a control, it was used the normal mean angular values of molar obtained by Ursi (1989), and this achievement came from panoramic radiographs of subjects with normal occlusion ranging in age from 12 to 17 years. Panoramic radiographs were taken for statistic analysis in all 3 stages (T1, T2, T3). The obtained data were statistically analysed through ANOVA Test dependent followed by Tukey test. The mean mesiodistal axial inclinations stages T1, T2, T3 were compared with normal mean values by the independent t test. The results showed that the first molars were more inclined to distal at posttreatment but five years later they tended to upright naturally, occupying the previous position, close to the original. When compared with normal values, only the left first maxillary molar showed in T2 a statistically different value to the normal. The correspondent values for the second maxillary molars did not show to be statistically significant when compared with each other, nor when compared with normal values. The treatment with the Pendulum, together with the orthodontic appliance, fosters an inclination of the molars to the distal, but tends to upright in the long-term posttreatment.
122

Análise da convecção forçada laminar em dutos circulares submetidos aos efeitos da condução axial e radiação

Veloso, Dhiego Luiz de Andrade 08 August 2015 (has links)
Submitted by Maike Costa (maiksebas@gmail.com) on 2017-05-23T14:15:11Z No. of bitstreams: 1 arquivo total.pdf: 1081749 bytes, checksum: 9f58d6baeffd1f939a659b2d2e3102be (MD5) / Made available in DSpace on 2017-05-23T14:15:11Z (GMT). No. of bitstreams: 1 arquivo total.pdf: 1081749 bytes, checksum: 9f58d6baeffd1f939a659b2d2e3102be (MD5) Previous issue date: 2015-08-08 / With the great technological advances experienced by humanity becomes providential depth knowledge about real processes of heat transfer, as well as a need arises to analyze them quantitatively. In the present work is studied the heat transfer in laminar forced convective in the entrance region of a circular tube considering the effects of axial conduction into the fluid and radiation, since in low Peclet numbers play an important role in heat transfer problems and its omission offers a significant error in the computation of the heat transfer rate. In the first part of this work is considered a slug-flow, whose exact analytical solution was discussed. In the second part of the work is considered a flow in the power law model, proposes an approximate analytic solution and numerical solution, as well as the comparison of these solutions. In this paper is used the hybrid numericanalytical method named Generalized Integral Transform Technique (GITT) to solve the energy equation. The temperature field and local Nusselt number are calculated for several values of Peclet numbers and with a boundary condition of first kind. The results presented in the form of tables and graphs permit to analyze the influence that the Peclet number and the power law index exercise in the temperature profile and the Nusselt number. The results of this study are presented in full compliance with the scientific literature. / Com o grande avanço tecnológico experimentado pela humanidade torna-se providencial um conhecimento aprofundado sobre os processos reais de transferência de calor, bem como surge uma necessidade de analisá-los quantitativamente. No presente trabalho estuda-se a transferência de calor na convecção forçada laminar na região de entrada térmica de um tubo circular considerando os efeitos de condução axial no fluido e de radiação, uma vez que em baixos números de Peclet desempenham um papel importante nos problemas de transferência de calor e sua omissão oferece um erro apreciável na computação da taxa de transferência de calor. Na primeira parte deste trabalho considerase um escoamento tipo pistão, cuja solução analítica exata foi discutida. Na segunda parte do trabalho considera-se um escoamento no modelo lei de potência, apresentando uma proposta de solução analítica aproximada e uma solução numérica, bem como a comparação entre as duas soluções. Neste trabalho utiliza-se o método híbrido numéricoanalítico denominado Técnica de Transformada Integral Generalizada (GITT) para resolver a equação da energia. O campo de temperatura e o número de Nusselt local são avaliados para vários valores do número de Peclet e uma condição de contorno do primeiro tipo. Os resultados, apresentados na forma de tabelas e gráficos, permitem analisar a influência que o número de Peclet e o índice lei de potência exercem no perfil de temperatura e no número de Nusselt. Os resultados obtidos neste trabalho se apresentam em total concordância com as literaturas científicas.
123

Componentes refrativos da hipermetropia em crianças com ambliopia por esotropia / Refractive components of hyperopia in children with esotropic amblyopia

Iara Debert 27 April 2012 (has links)
Objetivo: Estudar os componentes refrativos da hipermetropia em crianças com ambliopia por esotropia, comparando os olhos amblíopes com os olhos contralaterais. Métodos: Foram incluídos 37 pacientes de 5 a 8 anos de idade, com hipermetropia bilateral e ambliopia por esotropia. Foi realizada avaliação oftalmológica completa, incluindo refratometria sob cicloplegia, ceratometria e biometria ultrassonográfica modo A. Foram registrados profundidade da câmara anterior, espessura do cristalino, profundidade da câmara vítrea e comprimento axial total. O poder refrativo do cristalino foi calculado pelas equações de Bennett. Para comparar erro refrativo, poder da córnea, poder calculado do cristalino e componentes ecobiométricos entre os olhos amblíopes e os olhos contralaterais foi empregado o teste t de Student pareado. Para avaliar a relação entre os principais componentes refrativos individuais e o erro refrativo foram empregados o coeficiente de correlação de Pearson e a análise de regressão linear. Foram construídos também modelos multivariados, incluindo comprimento axial, poder da córnea e poder do cristalino. Resultados: Os olhos amblíopes apresentaram hipermetropia mais alta, menor poder da córnea, maior poder do cristalino, menor profundidade da câmara vítrea e menor comprimento axial. Não houve diferença entre os olhos quanto à profundidade da câmara anterior ou à espessura do cristalino. A variável que apresentou correlação mais forte com o erro refrativo foi a razão comprimento axial/raio de curvatura da córnea (r = -0.92, p < 0.001 nos olhos amblíopes e r = - 0.87, p < 0.001 nos olhos contralaterais). O comprimento axial representou 39,2% da explicação da variabilidade do erro refrativo nos olhos amblíopes e 35,5% nos olhos contralaterais. O modelo que combinou comprimento axial e poder da córnea explicou 85,7% e 79,6% da variabilidade do erro refrativo, respectivamente. Houve correlação significante entre comprimento axial e poder da córnea, indicando diminuição do poder da córnea com o aumento do comprimento axial e os coeficientes de correlação foram semelhantes entre os olhos amblíopes (r = -0.53, p <0.001) e os olhos contralaterais (r = -0.57, p < 0.001). Houve correlação significante entre comprimento axial e poder do cristalino, indicando diminuição do poder do cristalino com o aumento do comprimento axial e os coeficientes de correlação também foram semelhantes entre os olhos amblíopes (r = -0.72, p < 0.001) e os olhos contralaterais (r = -0.69, p < 0.001). Conclusão: As correlações entre os principais componentes refrativos e sua contribuição individual para o erro refrativo foram semelhantes nos olhos amblíopes e nos olhos contralaterais de crianças com esotropia, a despeito da hipermetropia mais alta nos olhos amblíopes / Purpose: To study the refractive components of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods: Thirty-seven patients (5 to 8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett`s equations. Paired Students t-tests were used to compare refractive error, corneal power, calculated lens power and ocular biometric measurements between amblyopic eyes and their fellow eyes. The relationship between the major oculometric parameters and refractive error was assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results: Amblyopic eyes were found to have significantly more hyperopic refraction, lesser corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio (r = -0.92, p < 0.001 for amblyopic and r = -0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. The combination of axial length and corneal power accounted for 85.7% and 79.6% of the refractive error variance respectively. A significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes (r = -0.53, p < 0.001) and fellow eyes (r = -0.57, p < 0.001). A significant correlation was found between axial length and lens power, indicating decreasing lens power with increasing axial length, and they were also similar for amblyopic eyes (r = -0.72, p < 0.001) and fellow eyes (r = -0.69, p < 0.001). Conclusion: The correlations among the major refractive components and their individual contribution to refractive error were similar in amblyopic and non-amblyopic eyes in esotropic children, despite more hyperopic refraction in amblyopic eyes
124

Artrodese atlanto-axial em cães tratada por ultra-som de baixa intensidade / The atlanto-axial arthrodeses in dogs treated by low intensity ultrasound

Luiz Otavio Rosa Gama 11 July 2002 (has links)
Neste estudo investigou-se em um modelo animal canino os efeitos do ultra-som de baixa intensidade na artrodese atlanto-axial com fixação metálica através do uso de parafusos compressivos. A investigação foi motivada pelos efeitos deste tratamento não-invasivo na consolidação óssea de fraturas recentes, com retardo de consolidação ou não-união (psedoartrose). A investigação foi realizada no segmento C1/C2 por este apresentar um elevado grau de mobilidade articular, quando em comparação com qualquer outra unidade motora da coluna vertebral. A artrodese foi realizada decorticando-se as faces articulares entre as duas primeiras vértebras cervicais para colocação de enxerto ósseo autólogo, coletado da cabeça do úmero. Após esse procedimento as vértebras foram fixadas por dois parafusos compressivos, colocados bilateralmente. Foram estabelecidos 2 grupos de estudo, sendo um de artrodeses tratadas por ultra-som de baixa intensidade (n=5) e outro de artrodeses não tratadas por ultra-som de baixa intensidade (n=3). O tempo do experimento para os animais de ambos os grupos foi de 60 dias após a cirurgia. Foram mantidos os parâmetros do ultra-som usado no tratamento de fraturas, mas a intensidade foi ligeiramente maior (38.17 2.66 mW/cm2). Os valores médio do grau de consolidação e da densidade mineral óssea (g/cm 2 ) nas artrodeses tratadas por ultra-som em comparação com as não tratadas foram 50% (p=0.002) e 29.3% (p=0.001) maiores, respectivamente. A apalpação manual das artrodese constatou 4 fusões sólidas e 1 fusão incompleta nos animais com artrodese tratada por ultra-som, e 3 fusões incompletas, ou seja, com a presença de movimento interarticular, nos animais com artrodese não tratada por ultra-som. / This study investigated the effect of low intensity ultrasound in spinal arthrodesis of the atlanto-axial vertebrae using dog as the animal model. The motivation for the investigation were the results of the same energy for treating fresh fractures, delayed union and non-unions. Eight mongrel dogs were randomly assigned to each of the two groups (treated and control) to undergo spinal fusion using compressive screws and autologous bone from the humerus. The vertebrae joint was decorticated before the bone graft. A specially designed constraint was used to focus the ultrasound over the dogs spine (treated group) 20 minutes per day. The animals were killed at 60 days for radiological, bone mineral density and manual palpation testing. The ultrasound parameters were the same used for treating fractures but the intensity was lightly higher (38.17 2.66 mW/cm2). The average value of the healing grade and the bone mineral density (g/cm2) were 50% (p=0.002) and 29.3% (p=0.001) higher in the arthrodesis treated by ultrasound, respectively. The manual palpation of the fusion sites indicated 4 solidly fused and 1 incomplete fusion in the arthrodesis treated by ultrasound.
125

Modelo computacional para projeto de compressores axiais / Computational method for designing of axial compressors

Lopes, Fernando de Oliveira 27 April 2007 (has links)
Orientador: Jorge Isaias Llagostera Beltran / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-08T17:53:07Z (GMT). No. of bitstreams: 1 Lopes_FernandodeOliveira_M.pdf: 4254683 bytes, checksum: 3714a253c99b8967319409a00b69058a (MD5) Previous issue date: 2007 / Resumo: Este trabalho apresenta o desenvolvimento de um programa computacional para modelagem inicial de compressores axiais de vários estágios pertencentes ao conjunto de turbinas a gás. O desenvolvimento do programa se baseia na metodologia adotada por Saravanamutto et al. (2001), faz uso da Primeira Lei da Termodinâmica para cálculo de potência consumida pelo compressor e da Segunda Lei da Termodinâmica para determinar o grau de irreversibilidade do sistema. O programa calcula a quantidade de estágios necessária para uma dada relação de pressão, a quantidade de palhetas por estágio e outros dados construtivos do compressor. O trabalho analisa a eficiência global de uma turbina a gás, avalia rendimento utilizando diferentes tipos combustíveis, estuda a influência da temperatura de entrada do ar no compressor, temperatura de entrada dos gases na turbina, e eficiência isentrópica do compressor e da turbina. Fatores que geram instabilidade no compressor são discutidos e algumas sugestões são apresentadas para evitar que compressores operem fora das condições iniciais. O trabalho apresenta procedimentos claros e detalhados para o préprojeto de um compressor de fluxo axial. Finalmente, o trabalho apresenta uma breve discussão sobre eficiência exergética de máquinas térmicas / Abstract: This work presents the developing of a computational program for designing axial compressors that hold multistage belonged gas turbine. The developing of the program is based on methodology adopted by Saravanamutto et al.(2001), it makes use of the First Law of Thermodynamic to calculate the power required by the axial compressor e the Second Law to calculate the level of irreversibilities. Beside of this the program presents the numbers of stages required for a given pressure ratio, the amount of blades per stage and other building parameters has been included to make a better analyze about the equipment. The work contains thermal efficiency analyzes of a gas turbines, where parameters such as fuels, temperature intlet turbine, environmental conditions, efficiency of the compressor and turbine are included. Other factors such as unstable conditions are discussed and solutions to avoid that axial compressors running in off design conditions. In summary the work provides a global view about thermal machines and how their parameters can influence both in the thermal and exergetic efficiency / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
126

Modificações esqueletais e apendiculares torácicas para captação de água do solo em caranguejos semiterrestres (Crustacea: Brachyura: Grapsoidea:Ocypodoidea) / Thoracic appendicular and skeletal modifications to capture soil water in semi-terrestrial crabs (Crustacea:Brachyura:Grapsoidea:Ocypodoidea)

Tainá Stauffer de Oliveira 10 October 2014 (has links)
A conquista do ambiente terrestre por caranguejos Brachyura é dependente da obtenção e reserva de água na câmara branquial durante o período de emersão. Uma maneira de se obter água do meio é através de tufos de cerdas hidrofílicas, capazes de captar água do solo por capilaridade. Sabe-se que essas cerdas hidrofílicas estão associadas à abertura de Müller e que a água captada é admitida na câmara branquial graças à diferença de pressão entre a câmara branquial e o meio externo, produzida pelos batimentos do escafognatito. Contudo, as modificações morfológicas esqueletais e apendiculares para a formação da abertura de Müller e a composição das cerdas do tufo não são conhecidos. Com o intuito de elucidar tais lacunas, foram estudados o esqueleto axial, apendicular e a quetotaxia de 22 espécies de caranguejos semiterrestres pertencentes às superfamílias Grapsoidea (Grapsidae, Sesarmidae, Varunidae e Gecarcinidae) e Ocypoidea (Ocypodidae e Ucididae). O estudo do esqueleto axial e apendicular revelou que a abertura de Müller é, na verdade, um canal complexo que pode ser composto por três componentes: o canal pleural, a calha apendicular e o tufo de cerdas. A água presente no substrato é captada pelo tufo de cerdas, é conduzida pela calha apendicular, passa pelo canal pleural para, enfim, ser admitida na câmara branquial. O tufo de cerdas é formado entre a face posterior do coxopodito do pereópode 3 e a face anterior do coxopodito do pereópode 4. Em Sesarmidae, o tufo também ocorre entre os coxopoditos dos pereópodes 2 e 3. Os representantes das superfamílias Grapsoidea e Ocypodoidea diferem quanto à formação do canal de Müller. Os tipos de cerdas presentes nos tufos de cerda associados ao canal de Müller são os mesmos encontrados em outros pereópodes e no bordo da região branquiostegal (cerdas simples, paposas e papo-serradas). A única exceção são as cerdas constritas presentes, exclusivamente, nos tufos de cerdas das espécies da família Ocypodidae. Nos tufos de Grapsoidea, a inserção de cerdas no coxopodito do pereópode 4 ocorre somente na sua porção ventral enquanto, em Ocypodoidea, as cerdas do coxopodito do pereópode 4 se inserem tanto na porção ventral como na porção distal. A calha apendicular pode ser formada entre as coxas dos pereópodes 5/6 ou 6/7, de formato cilíndrico ou semicilíndrico. A função da calha apendicular está associada com a condução da água entre o tufo de cerdas e o canal pleural, embora existam casos de formação do canal de Müller sem a presença da calha apendicular. O canal pleural pode ser aberto ou semitubular, ocorrendo, sempre, entre os pleuritos torácicos 6 e 7 e, em algumas espécies, também entre os pleuritos torácicos 5 e 6. O canal pleural aberto é formado pelo afastamento de dois pleuritos torácicos adjacentes; o canal semitubular é formado pela projeção do pleurito 7 sobre o pleurito torácico 6. Foram encontrados, pelo menos, sete padrões de organização do canal de Müller que variam entre a ausência completa da estrutura até a formação de um canal completo (que apresente tufo de cerdas, calha apendicular e canal pleural, concomitantemente). Ucides cordatus (Ucididae) apresentou modificações esqueletais singulares, bastante diferentes dos demais Ocypodoidea e também de Grapsoidea. As espécies que apresentam maior nível de terrestrialidade (família Gecarcinidae) foram as únicas que não apresentaram canal de Müller ou qualquer adaptação para captação de água do substrato. / The conquest of terrestrial environment by brachyuran crabs depends on the attainment and maintainability of water in the branchial chamber during the emersion period. One way to get environmental water is through tufts of hydrophilic setae, capable of picking up water from the soil by capillarity. It is known that these hydrophilic setae are attached to the Müllers opening and the collected water is admitted into the branchial chamber due to the pressure difference between the branchial chamber and the external environment, produced by the scaphognathite beating. However, the morphological modifications of the axial and appendicular skeleton to form the Müllers opening and the composition of the seta tuft are not known. In order to elucidate such gaps, the axial skeleton, the appendicular skeleton and the chaetotaxy of 22 species of semiterrestrial crabs belonging to superfamilies Grapsoidea (Grapsidae, Sesarmidae, Varunidae and Gecarcinidae) and Ocypodoidea (Ocypodidae and Ucididae) were studied. The study of the axial and appendicular skeleton revealed that the Müllers opening is actually a complex channel that may be comprised of three components: the pleural channel, the appendicular gutter and the setal tuft. The water is collected from the substrate by the setal tuft and carried through the appendicular gutter. Then it passes through the pleural channel to be finally admitted into the branchial chamber. The setal tuft is formed between the posterior face of the coxopodite of pereopod 3 and the anterior face of the coxopodite of pereopod 4. In Sesarmidae species, a second tuft also occurs between the coxopodites of pereopods 2 and 3. Representatives of the superfamilies Grapsoidea and Ocypoidea differ in the formation of Müllers channel. In Grapsoidea tuft, the setal insertion occurs only in the ventral portion of coxopodite of pereopod 4 while in Ocypodoidea, the insertion of these seta occurs both in the ventral and distal portions of coxopodite of pereopod 4. The types of seta which are present in setal tufts associated with the Müllers channel are the same found in other pereopods and in the edge of branchiostegal region (simple, paposes and paposerrate seta). The only exception is the constricted seta which is present exclusively in the setal tufts of Ocypodidae species. The appendicular gutter may be formed between the coxopodites of the 5/6 or 6/7 pereopods, in cylindrical or semi-cylindrical shape. The function of the appendicular gutter is associated with the water conduction between the setal tuft and the pleural channel, although there are cases in which the formation of Müllers channel happens without the presence of the appendicular gutter. Pleural channel can be opened or semitubular. They always occur between thoracic pleurites 6/7 and, in some species, between the thoracic pleurites 5 and 6 as well. The open pleural channel is formed by the spacing of two adjacent thoracic pleurites; the semitubular pleural channel is formed by the projection of pleurite 7 above pleurite 6. At least seven patterns of organization of the Müllers channel were found, ranging from the complete absence of the structure to the formation of a full channel (presenting setal tuft, appendicular gutter and pleural channel concurrently). Ucides cordatus (Ucididae) showed quite unique skeletal modifications, different from the others Ocypodoidea and also from the Grapsoidea. The species with the highest level of terrestriality (Gecarcinidae family) were the only ones who did not have Müllers channel or any adaptation to water abstraction from the substrate.
127

Artrodese da articulação interfalangeana proximal de equinos: avaliação biomecânica comparativa da técnica com placa de compressão dinâmica de 4,5mm e três orifícios, com dois parafusos transarticulares oblíquos de 5,5mm e técnica com placa \"Y\" de compressão bloqueada de 5,0mm e sete orifícios / Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of one 3-Hole 4.5-mm Narrow Dynamic Compression Plate with two 5.5mm oblique cortex screws technique and one 7-Hole 5.0mm \"Y\" locking compression plate technique

Carlos Adolfo Salazar Latorre 25 June 2013 (has links)
As claudicações são a principal causa de encaminhamento de equinos aos médicos veterinários e uma das maiores causas de encaminhamento destes animais aos hospitais de referência; sendo as fraturas, especialmente aquelas de ossos longos e articulares, as que têm menor índice de sucesso devido ao prognóstico reservado e alto custo do tratamento; entendendo como sucesso o retorno do animal à função ou manutenção da qualidade de vida. A articulação interfalangeana proximal (AIP) dos equinos é clinicamente importante devido à apresentação frequente de claudicação, com lesões que comprometem a vida esportiva e função do equino. O objetivo desta pesquisa foi comparar biomecanicamente as características de duas técnicas de artrodese da AIP em equinos, utilizando-se placa de compressão dinâmica (DCP) de 4.5mm e três orifícios em combinação com dois parafusos corticais transarticulares de 5.5mm oblíquos inseridos pela técnica de tração (lag screw) e placa em &#34;Y\" de compressão bloqueada (LCP) de 5,0mm e sete orifícios, com parafusos bloquados unicorticais e um parafuso cortical de 4.5mm oblíquo transarticular inserido no orifício central da placa, pela técnica de parafuso de tração. Foram utilizadas doze peças anatômicas de membros anteriores de equinos, das quais foi isolada a porção distal do membro desde a primeira falange até o casco. Uma vez preparadas as peças, cada par foi sorteado randomicamente para cada um dos dois grupos. Os modelos experimentais foram submetidos a ensaios biomecânicos de compressão axial em ciclo único até a sua falha. O tipo de falha ocorrida na placa, nos parafusos ou nos ossos foi avaliado, assim como a força à qual ocorreram estas falhas. Não houve diferença estatística significativa entre os grupos DCP e Y-LCP, nas variáveis rigidez e força máxima, quando submetidas a compressão axial até sua falha. Mesmo não havendo diferença entre as duas técnicas cirúrgicas na variável rigidez, a técnica Y-LCP possibilitou um procedimento menos invasivo e com menor tempo cirúrgico. Conclui-se que, as propriedades biomecânicas das duas técnicas de fixação (DCP e Y-LCP) são semelhantes nas condições testadas. / Lameness is the main cause of sport horses\' owners consulting equine veterinarians and one of the highest cause to send these animals to the reference hospitals. Long bones and joint fractures have the lesser rate of success, consequence of the hight cost of the treatment and poor prognosis. Understanding as success the return of the horse to previous athletic performance or at least to have useful life. The proximal interphalangeal joint (PIPJ) is clinically important because the injuries that involve it may threaten the horses sport life or its usefulness. The objective of this study was to compare the biomechanical properties of two PIPJ arthrodesis techniques using 4.5mm dynamic compression plate (DCP) in conjunction with two oblique abaxial transarticular 5.5mm cortical screws inserted in lag fashion and 5.0mm Y locking compression plate (Y-LCP) with unicortical locking screws and one axial transarticular 4.5mm cortex screw inserted in lag fashion through the midle plate hole. It was used twelve cadaveric adult equine forelimbs from the first phalanx to the foot. After full-limb preparations, each forelimb pair was randomly assigned to one of two treatment groups. Constructs were submited to axial compression single cycle to failure biomechanical testing. The failure of the screws, plate or bone, and the force at wich it happened was evaluated. There were no significant differences in construct stiffness or max force when loaded to failure, between the DCP and Y-LCP treatment groups. Even though there was no construct stiffness diffrences between the two techniques, the Y-LCP technique provided the possibility of a less invasive procedure with a shorter surgical time. In conclusion, the biomechanical properties of both fixation techniques (DCP and Y-LCP) are equivalent under the test conditions used.
128

Avaliação mecânica e de composição de liga metálica de dois tamanhos de anéis para fixador externo circular de três diferentes fabricantes para cães / Evaluation of mechanical and metal alloy composition of two sizes of circular external fixator rings for three different manufacturers for dogs

Jaqueline França dos Santos 14 December 2012 (has links)
Vários implantes cirúrgicos têm sido desenvolvidos para estabilizar fraturas em seres humanos e animais. O fixador esquelético externo circular de Ilizarov é método de fixação amplamente utilizado para tratamento de fraturas complexas, desvios angulares, bem como no alongamento ósseo. O anel destaca-se como componente fundamental desse dispositivo e as cargas de compressão no mesmo plano do anel são devidas principalmente a fios ligados de um lado ao outro do implante. O estudo teve como objetivo comparar a resistência à compressão axial de anéis de Ilizarov e analisar a composição da liga metálica desses anéis. Foram testados dois diâmetros de anéis de três fabricantes nacionais para os ensaios biomecânicos de compressão axial, divididos em dois grupos com quinze corpos de prova. Os testes foram realizados em máquina universal de ensaios Kratos&reg; modelo KE 3.000MP, dotada de célula de carga de 3000N com velocidade de ensaio de 10 milímetros por minuto. Os parâmetros força e deformação foram enviados ao computador IBM&reg;-PC através do sistema de aquisição analógica Lynx&reg; modelo ADS-2000, que permitiu a gravação dos parâmetros para posterior análise. Também avaliou-se a composição elementar dos anéis através do método TTPIXE (partículas induzidas pela emissão de raios X em alvos espessos) em PIXE externo. Os espectros foram acumulados em buffer-multicanal conectado a um micro-computador pessoal tipo IBM-PC&reg;. A redução de espectros de raios-X foi realizada por meio do programa AXIL. Concluiu-se que os anéis para fixador esquelético externo circular são compostos de liga metálica de alumínio e que existe diferença entre os fabricantes nacionais no ensaio mecânico de compressão axial, sendo que o fabricante A é mais rígido que os outros fabricantes para os dois diâmetros (60 e 80 milímetros) de anel e mais resistente que os outros fabricantes para o anel de 80 milímetros. / Various surgical implants have been developed to stabilize fractures in humans and animals. Ilizarov\'s circular external skeletal fixator is a fixation method widely used for the treatment of complex fractures, angular deviation, as well as in bone lengthening. The ring stands out as a fundamental component of the device and compression loads in the same plane of the ring are due mainly to wires connected from one side to another of the implant. The study aimed to compare the resistance to axial compression on Ilizarovs rings and analyze the alloy composition of these rings. Two diameters were tested of three domestic ring manufacturers for biomechanical axial compression, divided into two groups with fifteen specimens each group. The tests were performed in a universal test machine Kratos&reg; model 3.000MP KE, equipped with a 3000N load cell with a test speed of 10 mm per minute. The strength and deformation parameters were sent to the IBM&reg;-PC computer through the Lynx&reg; analog acquisition system model ADS-2000, which allowed the recording of the parameters for further analysis. Also, the rings alloy composition was evaluated using the TTPIXE method (thick-target particle induced X-ray emission) in external PIXE. The spectra were accumulated in a multi-channel buffer connected to an IBM&reg;-PC type personal microcomputer. The reduction of X-ray spectra was performed using the AXIL program. In conclusion the rings was made from aluminum alloy, witch differs in composition among different fabricants, also the rings showed differences performance in mechanical testing of axial compression, and the manufacturer A is more rigid than the other manufacturers for the two diameters (60 and 80 mm) ring and tougher than the other manufacturers to the 80 mm ring.
129

Verbesserung von maschinellen Lernmodellen durch Transferlernen zur Zeitreihenprognose im Radial-Axial Ringwalzen

Seitz, Johannes, Wang, Qinwen, Moser, Tobias, Brosius, Alexander, Kuhlenkötter, Bernd 28 November 2023 (has links)
Anwendung von maschinellen Lernverfahren (ML) in der Produktionstechnik, in Zeiten der Industrie 4.0, stark angestiegen. Insbesondere die Datenverfügbarkeit ist an dieser Stelle elementar und für die erfolgreiche Umsetzung einer ML-Applikation Voraussetzung. Falls für eine gegebene Problemstellung die Datenmenge oder -qualität nicht ausreichend ist, können Techniken, wie die Datenaugmentierung, der Einsatz von synthetischen Daten sowie das Transferlernen von ähnlichen Datensätzen Abhilfe schaffen. Innerhalb dieser Ausarbeitung wird das Konzept des Transferlernens im Bereich das Radial-Axial Ringwalzens (RAW) angewendet und am Beispiel der Zeitreihenprognose des Außendurchmessers über die Prozesszeit durchgeführt. Das Radial-Axial Ringwalzen ist ein warmumformendes Verfahren und dient der nahtlosen Ringherstellung.
130

Improvement of Machine Learning Models for Time Series Forecasting in Radial-Axial Ring Rolling through Transfer Learning

Seitz, Johannes, Wang, Qinwen, Moser, Tobias, Brosius, Alexander, Kuhlenkötter, Bernd 28 November 2023 (has links)
Due to the increasing computing power and corresponding algorithms, the use of machine learning (ML) in production technology has risen sharply in the age of Industry 4.0. Data availability in particular is fundamental at this point and a prerequisite for the successful implementation of a ML application. If the quantity or quality of data is insufficient for a given problem, techniques such as data augmentation, the use of synthetic data and transfer learning of similar data sets can provide a remedy. In this paper, the concept of transfer learning is applied in the field of radial-axial ring rolling (rarr) and implemented using the example of time series prediction of the outer diameter over the process time. Radial-axial ring rolling is a hot forming process and is used for seamless ring production.

Page generated in 0.0854 seconds